openstudio-common-measures 0.2.0 → 0.2.1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/CHANGELOG.md +44 -0
- data/Rakefile +3 -0
- data/lib/measures/ChangeBuildingLocation/measure.xml +11 -11
- data/lib/measures/ExportScheduleCSV/measure.rb +1 -1
- data/lib/measures/ExportScheduleCSV/measure.xml +16 -15
- data/lib/measures/ImportEnvelopeAndInternalLoadsFromIdf/measure.xml +7 -6
- data/lib/measures/MeterFlodPlot/measure.rb +1 -1
- data/lib/measures/MeterFlodPlot/measure.xml +16 -15
- data/lib/measures/ReportModelChanges/measure.xml +2 -2
- data/lib/measures/RunPeriodMultiple/measure.xml +12 -11
- data/lib/measures/ServerDirectoryCleanup/README.md +97 -3
- data/lib/measures/ServerDirectoryCleanup/measure.rb +1 -1
- data/lib/measures/ServerDirectoryCleanup/measure.xml +10 -59
- data/lib/measures/UnmetLoadHoursTroubleshooting/README.md +9 -3
- data/lib/measures/UnmetLoadHoursTroubleshooting/measure.rb +1 -1
- data/lib/measures/UnmetLoadHoursTroubleshooting/measure.xml +66 -17
- data/lib/measures/VentilationQAQC/README.md +9 -3
- data/lib/measures/VentilationQAQC/measure.rb +52 -45
- data/lib/measures/VentilationQAQC/measure.xml +25 -30
- data/lib/measures/ZoneReport/README.md +2 -2
- data/lib/measures/ZoneReport/measure.rb +1 -1
- data/lib/measures/ZoneReport/measure.xml +10 -11
- data/lib/measures/add_ems_to_control_ev_charging/LICENSE.MD.txt +15 -0
- data/lib/measures/{AddDaylightSensors → add_ems_to_control_ev_charging}/LICENSE.md +0 -0
- data/lib/measures/add_ems_to_control_ev_charging/ReadMe.MD +29 -0
- data/lib/measures/add_ems_to_control_ev_charging/measure.rb +288 -0
- data/lib/measures/add_ems_to_control_ev_charging/measure.xml +87 -0
- data/lib/measures/add_ev_load/LICENSE.MD.txt +15 -0
- data/lib/measures/{EnableDemandControlledVentilation → add_ev_load}/LICENSE.md +0 -0
- data/lib/measures/add_ev_load/ReadMe.MD +34 -0
- data/lib/measures/add_ev_load/measure.rb +328 -0
- data/lib/measures/add_ev_load/measure.xml +153 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/PSN_BuildingKey.csv +104 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/PSN_BuildingKey_v2.csv +104 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg1_dow1_flex1.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg1_dow1_flex2.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg1_dow1_flex3.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg1_dow2_flex1.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg1_dow2_flex2.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg1_dow2_flex3.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg1_dow3_flex1.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg1_dow3_flex2.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg1_dow3_flex3.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg2_dow1_flex1.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg2_dow1_flex2.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg2_dow1_flex3.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg2_dow2_flex1.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg2_dow2_flex2.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg2_dow2_flex3.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg2_dow3_flex1.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg2_dow3_flex2.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg2_dow3_flex3.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg3_dow1_flex1.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg3_dow1_flex2.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg3_dow1_flex3.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg3_dow2_flex1.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg3_dow2_flex2.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg3_dow2_flex3.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg3_dow3_flex1.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg3_dow3_flex2.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/chg3_dow3_flex3.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/fast_charge_15min_Saturday.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/fast_charge_15min_Sunday.csv +96 -0
- data/lib/measures/add_ev_load/resources/EV_Load_Profiles/fast_charge_15min_Weekday.csv +96 -0
- data/lib/measures/envelope_and_internal_load_breakdown/README.md +4 -3
- data/lib/measures/envelope_and_internal_load_breakdown/measure.rb +7 -4
- data/lib/measures/envelope_and_internal_load_breakdown/measure.xml +16 -17
- data/lib/measures/envelope_and_internal_load_breakdown/resources/report.html.erb +1 -0
- data/lib/measures/example_report/README.md +27 -5
- data/lib/measures/example_report/measure.rb +7 -4
- data/lib/measures/example_report/measure.xml +16 -29
- data/lib/measures/example_report/resources/report.html.erb +1 -0
- data/lib/measures/gem_env_report/measure.xml +1 -1
- data/lib/measures/generic_qaqc/README.md +187 -5
- data/lib/measures/generic_qaqc/measure.rb +1 -1
- data/lib/measures/generic_qaqc/measure.xml +15 -85
- data/lib/measures/generic_qaqc/resources/report.html.erb +1 -0
- data/lib/measures/hvac_psychrometric_chart/README.md +11 -5
- data/lib/measures/hvac_psychrometric_chart/measure.rb +1 -1
- data/lib/measures/hvac_psychrometric_chart/measure.xml +13 -18
- data/lib/measures/hvac_psychrometric_chart/resources/report.html.erb +1 -0
- data/lib/measures/inject_idf_objects/measure.xml +25 -24
- data/lib/measures/openstudio_results/README.md +195 -5
- data/lib/measures/openstudio_results/measure.rb +2 -2
- data/lib/measures/openstudio_results/measure.xml +30 -154
- data/lib/measures/openstudio_results/resources/report.html.erb +1 -0
- data/lib/measures/set_run_period/measure.xml +2 -2
- data/lib/measures/{EnableEconomizerControl → view_data}/LICENSE.md +0 -0
- data/lib/measures/view_data/README.md +64 -0
- data/lib/measures/{AddDaylightSensors → view_data}/README.md.erb +0 -0
- data/lib/measures/view_data/measure.rb +454 -0
- data/lib/measures/view_data/measure.xml +159 -0
- data/lib/measures/view_data/resources/report.html.in +2881 -0
- data/lib/measures/view_data/resources/va3c.rb +1021 -0
- data/lib/measures/{ImproveFanBeltEfficiency → view_model}/LICENSE.md +0 -0
- data/lib/measures/view_model/README.md +26 -0
- data/lib/measures/{EnableDemandControlledVentilation → view_model}/README.md.erb +0 -0
- data/lib/measures/view_model/measure.rb +146 -0
- data/lib/measures/view_model/measure.xml +98 -0
- data/lib/measures/view_model/resources/report.html.in +2881 -0
- data/lib/measures/view_model/resources/va3c.rb +1021 -0
- data/lib/openstudio/common_measures/version.rb +1 -1
- data/openstudio-common-measures.gemspec +1 -1
- metadata +61 -71
- data/lib/measures/AddDaylightSensors/README.md +0 -136
- data/lib/measures/AddDaylightSensors/measure.rb +0 -521
- data/lib/measures/AddDaylightSensors/measure.xml +0 -233
- data/lib/measures/EnableDemandControlledVentilation/README.md +0 -32
- data/lib/measures/EnableDemandControlledVentilation/measure.rb +0 -154
- data/lib/measures/EnableDemandControlledVentilation/measure.xml +0 -99
- data/lib/measures/EnableEconomizerControl/README.md +0 -48
- data/lib/measures/EnableEconomizerControl/README.md.erb +0 -42
- data/lib/measures/EnableEconomizerControl/measure.rb +0 -172
- data/lib/measures/EnableEconomizerControl/measure.xml +0 -124
- data/lib/measures/ImproveFanBeltEfficiency/README.md +0 -104
- data/lib/measures/ImproveFanBeltEfficiency/README.md.erb +0 -42
- data/lib/measures/ImproveFanBeltEfficiency/measure.rb +0 -366
- data/lib/measures/ImproveFanBeltEfficiency/measure.xml +0 -185
- data/lib/measures/ImproveMotorEfficiency/LICENSE.md +0 -27
- data/lib/measures/ImproveMotorEfficiency/README.md +0 -104
- data/lib/measures/ImproveMotorEfficiency/README.md.erb +0 -42
- data/lib/measures/ImproveMotorEfficiency/measure.rb +0 -365
- data/lib/measures/ImproveMotorEfficiency/measure.xml +0 -182
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/LICENSE.md +0 -27
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/README.md +0 -64
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/README.md.erb +0 -42
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/measure.rb +0 -422
- data/lib/measures/IncreaseInsulationRValueForExteriorWalls/measure.xml +0 -150
- data/lib/measures/IncreaseInsulationRValueForRoofs/LICENSE.md +0 -27
- data/lib/measures/IncreaseInsulationRValueForRoofs/README.md +0 -64
- data/lib/measures/IncreaseInsulationRValueForRoofs/README.md.erb +0 -42
- data/lib/measures/IncreaseInsulationRValueForRoofs/measure.rb +0 -422
- data/lib/measures/IncreaseInsulationRValueForRoofs/measure.xml +0 -143
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/README.md +0 -97
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/measure.rb +0 -450
- data/lib/measures/ReduceElectricEquipmentLoadsByPercentage/measure.xml +0 -186
- data/lib/measures/ReduceLightingLoadsByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceLightingLoadsByPercentage/README.md +0 -96
- data/lib/measures/ReduceLightingLoadsByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceLightingLoadsByPercentage/measure.rb +0 -513
- data/lib/measures/ReduceLightingLoadsByPercentage/measure.xml +0 -191
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/README.md +0 -104
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/measure.rb +0 -349
- data/lib/measures/ReduceSpaceInfiltrationByPercentage/measure.xml +0 -181
- data/lib/measures/ReduceVentilationByPercentage/LICENSE.md +0 -27
- data/lib/measures/ReduceVentilationByPercentage/README.md +0 -40
- data/lib/measures/ReduceVentilationByPercentage/README.md.erb +0 -42
- data/lib/measures/ReduceVentilationByPercentage/measure.rb +0 -291
- data/lib/measures/ReduceVentilationByPercentage/measure.xml +0 -96
- data/lib/measures/VentilationQAQC/ExampleModel.osm +0 -28468
- data/lib/measures/create_variable_speed_rtu/LICENSE.md +0 -27
- data/lib/measures/create_variable_speed_rtu/README.md +0 -120
- data/lib/measures/create_variable_speed_rtu/README.md.erb +0 -42
- data/lib/measures/create_variable_speed_rtu/measure.rb +0 -539
- data/lib/measures/create_variable_speed_rtu/measure.xml +0 -207
- data/lib/measures/radiant_slab_with_doas/LICENSE.md +0 -27
- data/lib/measures/radiant_slab_with_doas/README.md +0 -156
- data/lib/measures/radiant_slab_with_doas/README.md.erb +0 -42
- data/lib/measures/radiant_slab_with_doas/measure.rb +0 -403
- data/lib/measures/radiant_slab_with_doas/measure.xml +0 -345
@@ -1,27 +0,0 @@
|
|
1
|
-
OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC. All rights reserved.
|
2
|
-
|
3
|
-
Redistribution and use in source and binary forms, with or without modification, are permitted
|
4
|
-
provided that the following conditions are met:
|
5
|
-
|
6
|
-
(1) Redistributions of source code must retain the above copyright notice, this list of conditions
|
7
|
-
and the following disclaimer.
|
8
|
-
|
9
|
-
(2) Redistributions in binary form must reproduce the above copyright notice, this list of conditions
|
10
|
-
and the following disclaimer in the documentation and/or other materials provided with the distribution.
|
11
|
-
|
12
|
-
(3) Neither the name of the copyright holder nor the names of any contributors may be used to endorse
|
13
|
-
or promote products derived from this software without specific prior written permission from the
|
14
|
-
respective party.
|
15
|
-
|
16
|
-
(4) Other than as required in clauses (1) and (2), distributions in any form of modifications or other
|
17
|
-
derivative works may not use the "OpenStudio" trademark, "OS", "os", or any other confusingly similar
|
18
|
-
designation without specific prior written permission from Alliance for Sustainable Energy, LLC.
|
19
|
-
|
20
|
-
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED
|
21
|
-
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
|
22
|
-
PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER, THE UNITED STATES GOVERNMENT,
|
23
|
-
OR ANY CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
24
|
-
DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA,
|
25
|
-
OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
|
26
|
-
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
|
27
|
-
SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
@@ -1,120 +0,0 @@
|
|
1
|
-
|
2
|
-
|
3
|
-
###### (Automatically generated documentation)
|
4
|
-
|
5
|
-
# Create Variable Speed RTU
|
6
|
-
|
7
|
-
## Description
|
8
|
-
This measure examines the existing HVAC system(s) present in the current OpenStudio model. If a constant-speed system is found, the user can opt to have the measure replace that system with a variable-speed RTU. 'Variable speed' in this case means that the compressor will be operated using either two or four stages (user's choice). The user can choose between using a gas heating coil, or a direct-expansion (DX) heating coil. Additionally, the user is able to enter the EER (cooling) and COP (heating) values for each DX stage. This measure allows users to easily identify the impact of improved part-load efficiency.
|
9
|
-
|
10
|
-
## Modeler Description
|
11
|
-
This measure loops through the existing airloops, looking for loops that have a constant speed fan. (Note that if an object such as an AirloopHVAC:UnitarySystem is present in the model, that the measure will NOT identify that loop as either constant- or variable-speed, since the fan is located inside the UnitarySystem object.) The user can designate which constant-speed airloop they'd like to apply the measure to, or opt to apply the measure to all airloops. The measure then replaces the supply components on the airloop with an AirloopHVAC:UnitarySystem object. Any DX coils added to the UnitarySystem object are of the type CoilCoolingDXMultiSpeed / CoilHeatingDXMultiSpeed, with the number of stages set to either two or four, depending on user input. If the user opts for a gas furnace, an 80% efficient CoilHeatingGas object is added. Fan properties (pressure rise and total efficiency) are transferred automatically from the existing (but deleted) constant speed fan to the new variable-speed fan. Currently, this measure is only applicable to the Standalone Retail DOE Prototype building model, but it has been structured to facilitate expansion to other models with a minimum of effort.
|
12
|
-
|
13
|
-
## Measure Type
|
14
|
-
ModelMeasure
|
15
|
-
|
16
|
-
## Taxonomy
|
17
|
-
|
18
|
-
|
19
|
-
## Arguments
|
20
|
-
|
21
|
-
|
22
|
-
### Choose an Air Loop to change from CAV to VAV.
|
23
|
-
|
24
|
-
**Name:** object,
|
25
|
-
**Type:** Choice,
|
26
|
-
**Units:** ,
|
27
|
-
**Required:** true,
|
28
|
-
**Model Dependent:** false
|
29
|
-
|
30
|
-
### Choose the type of cooling coil.
|
31
|
-
|
32
|
-
**Name:** cooling_coil_type,
|
33
|
-
**Type:** Choice,
|
34
|
-
**Units:** ,
|
35
|
-
**Required:** true,
|
36
|
-
**Model Dependent:** false
|
37
|
-
|
38
|
-
### Rated Cooling Coil EER
|
39
|
-
|
40
|
-
**Name:** rated_cc_eer,
|
41
|
-
**Type:** Double,
|
42
|
-
**Units:** ,
|
43
|
-
**Required:** false,
|
44
|
-
**Model Dependent:** false
|
45
|
-
|
46
|
-
### Cooling Coil EER at 75% Capacity
|
47
|
-
|
48
|
-
**Name:** three_quarter_cc_eer,
|
49
|
-
**Type:** Double,
|
50
|
-
**Units:** ,
|
51
|
-
**Required:** false,
|
52
|
-
**Model Dependent:** false
|
53
|
-
|
54
|
-
### Cooling Coil EER at 50% Capacity
|
55
|
-
|
56
|
-
**Name:** half_cc_eer,
|
57
|
-
**Type:** Double,
|
58
|
-
**Units:** ,
|
59
|
-
**Required:** false,
|
60
|
-
**Model Dependent:** false
|
61
|
-
|
62
|
-
### Cooling Coil EER at 25% Capacity
|
63
|
-
|
64
|
-
**Name:** quarter_cc_eer,
|
65
|
-
**Type:** Double,
|
66
|
-
**Units:** ,
|
67
|
-
**Required:** false,
|
68
|
-
**Model Dependent:** false
|
69
|
-
|
70
|
-
### Choose the type of heating coil.
|
71
|
-
|
72
|
-
**Name:** heating_coil_type,
|
73
|
-
**Type:** Choice,
|
74
|
-
**Units:** ,
|
75
|
-
**Required:** true,
|
76
|
-
**Model Dependent:** false
|
77
|
-
|
78
|
-
### Rated Gas Heating Coil Efficiency (0-1.00)
|
79
|
-
|
80
|
-
**Name:** rated_hc_gas_efficiency,
|
81
|
-
**Type:** Double,
|
82
|
-
**Units:** ,
|
83
|
-
**Required:** false,
|
84
|
-
**Model Dependent:** false
|
85
|
-
|
86
|
-
### Rated Heating Coil COP
|
87
|
-
|
88
|
-
**Name:** rated_hc_cop,
|
89
|
-
**Type:** Double,
|
90
|
-
**Units:** ,
|
91
|
-
**Required:** false,
|
92
|
-
**Model Dependent:** false
|
93
|
-
|
94
|
-
### Heating Coil COP at 75% Capacity
|
95
|
-
|
96
|
-
**Name:** three_quarter_hc_cop,
|
97
|
-
**Type:** Double,
|
98
|
-
**Units:** ,
|
99
|
-
**Required:** false,
|
100
|
-
**Model Dependent:** false
|
101
|
-
|
102
|
-
### Heating Coil COP at 50% Capacity
|
103
|
-
|
104
|
-
**Name:** half_hc_cop,
|
105
|
-
**Type:** Double,
|
106
|
-
**Units:** ,
|
107
|
-
**Required:** false,
|
108
|
-
**Model Dependent:** false
|
109
|
-
|
110
|
-
### Heating Coil COP at 25% Capacity
|
111
|
-
|
112
|
-
**Name:** quarter_hc_cop,
|
113
|
-
**Type:** Double,
|
114
|
-
**Units:** ,
|
115
|
-
**Required:** false,
|
116
|
-
**Model Dependent:** false
|
117
|
-
|
118
|
-
|
119
|
-
|
120
|
-
|
@@ -1,42 +0,0 @@
|
|
1
|
-
<%#= README.md.erb is used to auto-generate README.md. %>
|
2
|
-
<%#= To manually maintain README.md throw away README.md.erb and manually edit README.md %>
|
3
|
-
###### (Automatically generated documentation)
|
4
|
-
|
5
|
-
# <%= name %>
|
6
|
-
|
7
|
-
## Description
|
8
|
-
<%= description %>
|
9
|
-
|
10
|
-
## Modeler Description
|
11
|
-
<%= modelerDescription %>
|
12
|
-
|
13
|
-
## Measure Type
|
14
|
-
<%= measureType %>
|
15
|
-
|
16
|
-
## Taxonomy
|
17
|
-
<%= taxonomy %>
|
18
|
-
|
19
|
-
## Arguments
|
20
|
-
|
21
|
-
<% arguments.each do |argument| %>
|
22
|
-
### <%= argument[:display_name] %>
|
23
|
-
<%= argument[:description] %>
|
24
|
-
**Name:** <%= argument[:name] %>,
|
25
|
-
**Type:** <%= argument[:type] %>,
|
26
|
-
**Units:** <%= argument[:units] %>,
|
27
|
-
**Required:** <%= argument[:required] %>,
|
28
|
-
**Model Dependent:** <%= argument[:model_dependent] %>
|
29
|
-
<% end %>
|
30
|
-
|
31
|
-
<% if arguments.size == 0 %>
|
32
|
-
<%= "This measure does not have any user arguments" %>
|
33
|
-
<% end %>
|
34
|
-
|
35
|
-
<% if outputs.size > 0 %>
|
36
|
-
## Outputs
|
37
|
-
<% output_names = [] %>
|
38
|
-
<% outputs.each do |output| %>
|
39
|
-
<% output_names << output[:display_name] %>
|
40
|
-
<% end %>
|
41
|
-
<%= output_names.join(", ") %>
|
42
|
-
<% end %>
|
@@ -1,539 +0,0 @@
|
|
1
|
-
# *******************************************************************************
|
2
|
-
# OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC.
|
3
|
-
# All rights reserved.
|
4
|
-
# Redistribution and use in source and binary forms, with or without
|
5
|
-
# modification, are permitted provided that the following conditions are met:
|
6
|
-
#
|
7
|
-
# (1) Redistributions of source code must retain the above copyright notice,
|
8
|
-
# this list of conditions and the following disclaimer.
|
9
|
-
#
|
10
|
-
# (2) Redistributions in binary form must reproduce the above copyright notice,
|
11
|
-
# this list of conditions and the following disclaimer in the documentation
|
12
|
-
# and/or other materials provided with the distribution.
|
13
|
-
#
|
14
|
-
# (3) Neither the name of the copyright holder nor the names of any contributors
|
15
|
-
# may be used to endorse or promote products derived from this software without
|
16
|
-
# specific prior written permission from the respective party.
|
17
|
-
#
|
18
|
-
# (4) Other than as required in clauses (1) and (2), distributions in any form
|
19
|
-
# of modifications or other derivative works may not use the "OpenStudio"
|
20
|
-
# trademark, "OS", "os", or any other confusingly similar designation without
|
21
|
-
# specific prior written permission from Alliance for Sustainable Energy, LLC.
|
22
|
-
#
|
23
|
-
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER(S) AND ANY CONTRIBUTORS
|
24
|
-
# "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
|
25
|
-
# THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
26
|
-
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER(S), ANY CONTRIBUTORS, THE
|
27
|
-
# UNITED STATES GOVERNMENT, OR THE UNITED STATES DEPARTMENT OF ENERGY, NOR ANY OF
|
28
|
-
# THEIR EMPLOYEES, BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
|
29
|
-
# EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT
|
30
|
-
# OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
|
31
|
-
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
|
32
|
-
# STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
33
|
-
# OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
34
|
-
# *******************************************************************************
|
35
|
-
|
36
|
-
# see the URL below for information on how to write OpenStudio measures
|
37
|
-
# http://nrel.github.io/OpenStudio-user-documentation/reference/measure_writing_guide/
|
38
|
-
|
39
|
-
# start the measure
|
40
|
-
class CreateVariableSpeedRTU < OpenStudio::Ruleset::ModelUserScript
|
41
|
-
# human readable name
|
42
|
-
def name
|
43
|
-
return 'Create Variable Speed RTU'
|
44
|
-
end
|
45
|
-
|
46
|
-
# human readable description
|
47
|
-
def description
|
48
|
-
return "This measure examines the existing HVAC system(s) present in the current OpenStudio model. If a constant-speed system is found, the user can opt to have the measure replace that system with a variable-speed RTU. 'Variable speed' in this case means that the compressor will be operated using either two or four stages (user's choice). The user can choose between using a gas heating coil, or a direct-expansion (DX) heating coil. Additionally, the user is able to enter the EER (cooling) and COP (heating) values for each DX stage. This measure allows users to easily identify the impact of improved part-load efficiency."
|
49
|
-
end
|
50
|
-
|
51
|
-
# human readable description of modeling approach
|
52
|
-
def modeler_description
|
53
|
-
return "This measure loops through the existing airloops, looking for loops that have a constant speed fan. (Note that if an object such as an AirloopHVAC:UnitarySystem is present in the model, that the measure will NOT identify that loop as either constant- or variable-speed, since the fan is located inside the UnitarySystem object.) The user can designate which constant-speed airloop they'd like to apply the measure to, or opt to apply the measure to all airloops. The measure then replaces the supply components on the airloop with an AirloopHVAC:UnitarySystem object. Any DX coils added to the UnitarySystem object are of the type CoilCoolingDXMultiSpeed / CoilHeatingDXMultiSpeed, with the number of stages set to either two or four, depending on user input. If the user opts for a gas furnace, an 80% efficient CoilHeatingGas object is added. Fan properties (pressure rise and total efficiency) are transferred automatically from the existing (but deleted) constant speed fan to the new variable-speed fan. Currently, this measure is only applicable to the Standalone Retail DOE Prototype building model, but it has been structured to facilitate expansion to other models with a minimum of effort."
|
54
|
-
end
|
55
|
-
|
56
|
-
# define the arguments that the user will input
|
57
|
-
def arguments(model)
|
58
|
-
args = OpenStudio::Ruleset::OSArgumentVector.new
|
59
|
-
|
60
|
-
# populate choice argument for air loops in the model
|
61
|
-
air_loop_handles = OpenStudio::StringVector.new
|
62
|
-
air_loop_display_names = OpenStudio::StringVector.new
|
63
|
-
|
64
|
-
# putting air loop names into hash
|
65
|
-
air_loop_args = model.getAirLoopHVACs
|
66
|
-
air_loop_args_hash = {}
|
67
|
-
air_loop_args.each do |air_loop_arg|
|
68
|
-
air_loop_args_hash[air_loop_arg.name.to_s] = air_loop_arg
|
69
|
-
end
|
70
|
-
|
71
|
-
# looping through sorted hash of air loops
|
72
|
-
air_loop_args_hash.sort.map do |air_loop_name, air_loop|
|
73
|
-
air_loop.supplyComponents.each do |supply_comp|
|
74
|
-
# find CAV fans
|
75
|
-
if supply_comp.to_FanConstantVolume.is_initialized
|
76
|
-
air_loop_handles << air_loop.handle.to_s
|
77
|
-
air_loop_display_names << air_loop_name
|
78
|
-
end
|
79
|
-
end
|
80
|
-
end
|
81
|
-
|
82
|
-
# add building to string vector with air loops
|
83
|
-
building = model.getBuilding
|
84
|
-
air_loop_handles << building.handle.to_s
|
85
|
-
air_loop_display_names << '*All CAV Air Loops*'
|
86
|
-
|
87
|
-
# make an argument for air loops
|
88
|
-
object = OpenStudio::Ruleset::OSArgument.makeChoiceArgument('object', air_loop_handles, air_loop_display_names, true)
|
89
|
-
object.setDisplayName('Choose an Air Loop to change from CAV to VAV.')
|
90
|
-
object.setDefaultValue('*All CAV Air Loops*') # if no air loop is chosen this will run on all air loops
|
91
|
-
args << object
|
92
|
-
|
93
|
-
# make an argument for cooling type
|
94
|
-
cooling_coil_options = OpenStudio::StringVector.new
|
95
|
-
cooling_coil_options << 'Two-Stage Compressor'
|
96
|
-
cooling_coil_options << 'Four-Stage Compressor'
|
97
|
-
cooling_coil_type = OpenStudio::Ruleset::OSArgument.makeChoiceArgument('cooling_coil_type', cooling_coil_options, true)
|
98
|
-
cooling_coil_type.setDisplayName('Choose the type of cooling coil.')
|
99
|
-
cooling_coil_type.setDefaultValue('Two-Stage Compressor')
|
100
|
-
args << cooling_coil_type
|
101
|
-
|
102
|
-
# make an argument for rated cooling coil EER
|
103
|
-
rated_cc_eer = OpenStudio::Ruleset::OSArgument.makeDoubleArgument('rated_cc_eer', false)
|
104
|
-
rated_cc_eer.setDisplayName('Rated Cooling Coil EER')
|
105
|
-
# rated_cc_eer.setDefaultValue(0.0)
|
106
|
-
args << rated_cc_eer
|
107
|
-
|
108
|
-
# make an argument for 75% cooling coil EER
|
109
|
-
three_quarter_cc_eer = OpenStudio::Ruleset::OSArgument.makeDoubleArgument('three_quarter_cc_eer', false)
|
110
|
-
three_quarter_cc_eer.setDisplayName('Cooling Coil EER at 75% Capacity')
|
111
|
-
# three_quarter_cc_eer.setDefaultValue(0.0)
|
112
|
-
args << three_quarter_cc_eer
|
113
|
-
|
114
|
-
# make an argument for 50% cooling coil EER
|
115
|
-
half_cc_eer = OpenStudio::Ruleset::OSArgument.makeDoubleArgument('half_cc_eer', false)
|
116
|
-
half_cc_eer.setDisplayName('Cooling Coil EER at 50% Capacity')
|
117
|
-
# half_cc_eer.setDefaultValue(0.0)
|
118
|
-
args << half_cc_eer
|
119
|
-
|
120
|
-
# make an argument for 25% cooling coil EER
|
121
|
-
quarter_cc_eer = OpenStudio::Ruleset::OSArgument.makeDoubleArgument('quarter_cc_eer', false)
|
122
|
-
quarter_cc_eer.setDisplayName('Cooling Coil EER at 25% Capacity')
|
123
|
-
# quarter_cc_eer.setDefaultValue(0.0)
|
124
|
-
args << quarter_cc_eer
|
125
|
-
|
126
|
-
# make an argument for heating type
|
127
|
-
heating_coil_options = OpenStudio::StringVector.new
|
128
|
-
heating_coil_options << 'Gas Heating Coil'
|
129
|
-
heating_coil_options << 'Heat Pump'
|
130
|
-
heating_coil_type = OpenStudio::Ruleset::OSArgument.makeChoiceArgument('heating_coil_type', heating_coil_options, true)
|
131
|
-
heating_coil_type.setDisplayName('Choose the type of heating coil.')
|
132
|
-
heating_coil_type.setDefaultValue('Gas Heating Coil')
|
133
|
-
args << heating_coil_type
|
134
|
-
|
135
|
-
# make an argument for rated gas heating coil efficiency
|
136
|
-
rated_hc_gas_efficiency = OpenStudio::Ruleset::OSArgument.makeDoubleArgument('rated_hc_gas_efficiency', false)
|
137
|
-
rated_hc_gas_efficiency.setDisplayName('Rated Gas Heating Coil Efficiency (0-1.00)')
|
138
|
-
# rated_hc_gas_efficiency.setDefaultValue(0.0)
|
139
|
-
args << rated_hc_gas_efficiency
|
140
|
-
|
141
|
-
# make an argument for rated heating coil COP
|
142
|
-
rated_hc_cop = OpenStudio::Ruleset::OSArgument.makeDoubleArgument('rated_hc_cop', false)
|
143
|
-
rated_hc_cop.setDisplayName('Rated Heating Coil COP')
|
144
|
-
# rated_hc_cop.setDefaultValue(0.0)
|
145
|
-
args << rated_hc_cop
|
146
|
-
|
147
|
-
# make an argument for 75% heating coil COP
|
148
|
-
three_quarter_hc_cop = OpenStudio::Ruleset::OSArgument.makeDoubleArgument('three_quarter_hc_cop', false)
|
149
|
-
three_quarter_hc_cop.setDisplayName('Heating Coil COP at 75% Capacity')
|
150
|
-
# three_quarter_hc_cop.setDefaultValue(0.0)
|
151
|
-
args << three_quarter_hc_cop
|
152
|
-
|
153
|
-
# make an argument for 50% heating coil COP
|
154
|
-
half_hc_cop = OpenStudio::Ruleset::OSArgument.makeDoubleArgument('half_hc_cop', false)
|
155
|
-
half_hc_cop.setDisplayName('Heating Coil COP at 50% Capacity')
|
156
|
-
# half_hc_cop.setDefaultValue(0.0)
|
157
|
-
args << half_hc_cop
|
158
|
-
|
159
|
-
# make an argument for 25% heating coil COP
|
160
|
-
quarter_hc_cop = OpenStudio::Ruleset::OSArgument.makeDoubleArgument('quarter_hc_cop', false)
|
161
|
-
quarter_hc_cop.setDisplayName('Heating Coil COP at 25% Capacity')
|
162
|
-
# quarter_hc_cop.setDefaultValue(0.0)
|
163
|
-
args << quarter_hc_cop
|
164
|
-
|
165
|
-
return args
|
166
|
-
end # end the arguments method
|
167
|
-
|
168
|
-
# define what happens when the measure is run
|
169
|
-
def run(model, runner, user_arguments)
|
170
|
-
super(model, runner, user_arguments)
|
171
|
-
|
172
|
-
# Use the built-in error checking
|
173
|
-
if !runner.validateUserArguments(arguments(model), user_arguments)
|
174
|
-
return false
|
175
|
-
end
|
176
|
-
|
177
|
-
# Assign the user inputs to variables
|
178
|
-
object = runner.getOptionalWorkspaceObjectChoiceValue('object', user_arguments, model)
|
179
|
-
cooling_coil_type = runner.getStringArgumentValue('cooling_coil_type', user_arguments)
|
180
|
-
rated_cc_eer = runner.getOptionalDoubleArgumentValue('rated_cc_eer', user_arguments)
|
181
|
-
three_quarter_cc_eer = runner.getOptionalDoubleArgumentValue('three_quarter_cc_eer', user_arguments)
|
182
|
-
half_cc_eer = runner.getOptionalDoubleArgumentValue('half_cc_eer', user_arguments)
|
183
|
-
quarter_cc_eer = runner.getOptionalDoubleArgumentValue('quarter_cc_eer', user_arguments)
|
184
|
-
heating_coil_type = runner.getStringArgumentValue('heating_coil_type', user_arguments)
|
185
|
-
rated_hc_gas_efficiency = runner.getOptionalDoubleArgumentValue('rated_hc_gas_efficiency', user_arguments)
|
186
|
-
rated_hc_cop = runner.getOptionalDoubleArgumentValue('rated_hc_cop', user_arguments)
|
187
|
-
three_quarter_hc_cop = runner.getOptionalDoubleArgumentValue('three_quarter_hc_cop', user_arguments)
|
188
|
-
half_hc_cop = runner.getOptionalDoubleArgumentValue('half_hc_cop', user_arguments)
|
189
|
-
quarter_hc_cop = runner.getOptionalDoubleArgumentValue('quarter_hc_cop', user_arguments)
|
190
|
-
|
191
|
-
if rated_cc_eer.empty?
|
192
|
-
runner.registerError('User must enter a value for the rated capacity cooling coil EER.')
|
193
|
-
return false
|
194
|
-
elsif rated_cc_eer.to_f <= 0
|
195
|
-
runner.registerError("Invalid rated cooling coil EER value of #{rated_cc_eer} entered. EER must be >0.")
|
196
|
-
return false
|
197
|
-
end
|
198
|
-
|
199
|
-
if three_quarter_cc_eer.empty? && cooling_coil_type == 'Four-Stage Compressor'
|
200
|
-
runner.registerError('User must enter a value for 75% capacity cooling coil EER.')
|
201
|
-
return false
|
202
|
-
elsif three_quarter_cc_eer.to_f <= 0 && cooling_coil_type == 'Four-Stage Compressor'
|
203
|
-
runner.registerError("Invalid 75% capacity cooling coil EER value of #{three_quarter_cc_eer} entered. EER must be >0.")
|
204
|
-
return false
|
205
|
-
end
|
206
|
-
|
207
|
-
if half_cc_eer.empty?
|
208
|
-
runner.registerError('User must enter a value for 50% capacity cooling coil EER.')
|
209
|
-
return false
|
210
|
-
elsif half_cc_eer.to_f <= 0
|
211
|
-
runner.registerError("Invalid 50% capacity cooling coil EER value of #{half_cc_eer} entered. EER must be >0.")
|
212
|
-
return false
|
213
|
-
end
|
214
|
-
|
215
|
-
if quarter_cc_eer.empty? && cooling_coil_type == 'Four-Stage Compressor'
|
216
|
-
runner.registerError('User must enter a value for 25% capacity cooling coil EER.')
|
217
|
-
return false
|
218
|
-
elsif quarter_cc_eer.to_f <= 0 && cooling_coil_type == 'Four-Stage Compressor'
|
219
|
-
runner.registerError("Invalid 25% capacity cooling coil EER value of #{quarter_cc_eer} entered. EER must be >0.")
|
220
|
-
return false
|
221
|
-
end
|
222
|
-
|
223
|
-
if rated_hc_gas_efficiency.empty? && heating_coil_type == 'Gas Heating Coil'
|
224
|
-
runner.registerError('User must enter a value for the rated gas heating coil efficiency.')
|
225
|
-
return false
|
226
|
-
elsif rated_hc_gas_efficiency.to_f <= 0 && heating_coil_type == 'Gas Heating Coil'
|
227
|
-
runner.registerError("Invalid rated heating coil efficiency value of #{rated_hc_gas_efficiency} entered. Value must be >0.")
|
228
|
-
return false
|
229
|
-
elsif rated_hc_gas_efficiency.to_f > 1 && heating_coil_type == 'Gas Heating Coil'
|
230
|
-
runner.registerError("Invalid rated heating coil efficiency value of #{rated_hc_gas_efficiency} entered. Value must be between 0 and 1.")
|
231
|
-
return false
|
232
|
-
end
|
233
|
-
|
234
|
-
if rated_hc_cop.empty? && heating_coil_type == 'Heat Pump'
|
235
|
-
runner.registerError('User must enter a value for the rated heating coil COP.')
|
236
|
-
return false
|
237
|
-
elsif rated_hc_cop.to_f <= 0 && heating_coil_type == 'Heat Pump'
|
238
|
-
runner.registerError("Invalid rated heating coil COP value of #{rated_hc_cop} entered. COP must be >0.")
|
239
|
-
return false
|
240
|
-
end
|
241
|
-
|
242
|
-
if three_quarter_hc_cop.empty? && heating_coil_type == 'Heat Pump' && cooling_coil_type == 'Four-Stage Compressor'
|
243
|
-
runner.registerError('User must enter a value for 75% capacity heating coil COP.')
|
244
|
-
return false
|
245
|
-
elsif half_hc_cop.to_f <= 0 && heating_coil_type == 'Heat Pump' && cooling_coil_type == 'Four-Stage Compressor'
|
246
|
-
runner.registerError("Invalid 75% capacity heating coil COP value of #{three_quarter_hc_cop} entered. COP must be >0.")
|
247
|
-
return false
|
248
|
-
end
|
249
|
-
|
250
|
-
if half_hc_cop.empty? && heating_coil_type == 'Heat Pump'
|
251
|
-
runner.registerError('User must enter a value for 50% capacity heating coil COP.')
|
252
|
-
return false
|
253
|
-
elsif half_hc_cop.to_f <= 0 && heating_coil_type == 'Heat Pump'
|
254
|
-
runner.registerError("Invalid 50% capacity heating coil COP value of #{half_hc_cop} entered. COP must be >0.")
|
255
|
-
return false
|
256
|
-
end
|
257
|
-
|
258
|
-
if quarter_hc_cop.empty? && heating_coil_type == 'Heat Pump' && cooling_coil_type == 'Four-Stage Compressor'
|
259
|
-
runner.registerError('User must enter a value for 25% capacity heating coil COP.')
|
260
|
-
return false
|
261
|
-
elsif quarter_hc_cop.to_f <= 0 && heating_coil_type == 'Heat Pump' && cooling_coil_type == 'Four-Stage Compressor'
|
262
|
-
runner.registerError("Invalid 25% capacity heating coil COP value of #{quarter_hc_cop} entered. COP must be >0.")
|
263
|
-
return false
|
264
|
-
end
|
265
|
-
|
266
|
-
# Report initial condition of model
|
267
|
-
initial_cav_airloops = 0
|
268
|
-
initial_vav_airloops = 0
|
269
|
-
model.getAirLoopHVACs.each do |air_loop|
|
270
|
-
# Loop through all supply components on the airloop and find CAV and VAV fans
|
271
|
-
air_loop.supplyComponents.each do |supply_comp|
|
272
|
-
if supply_comp.to_FanConstantVolume.is_initialized
|
273
|
-
initial_cav_airloops += 1
|
274
|
-
elsif supply_comp.to_FanVariableVolume.is_initialized
|
275
|
-
initial_vav_airloops += 1
|
276
|
-
end
|
277
|
-
end
|
278
|
-
end
|
279
|
-
runner.registerInitialCondition("The building started with #{initial_cav_airloops} CAV air loops and #{initial_vav_airloops} VAV air loops.")
|
280
|
-
|
281
|
-
# Check the air loop selection
|
282
|
-
apply_to_all_air_loops = false
|
283
|
-
selected_airloop = nil
|
284
|
-
if object.empty?
|
285
|
-
handle = runner.getStringArgumentValue('object', user_arguments)
|
286
|
-
if handle.empty?
|
287
|
-
runner.registerError('No air loop was chosen.')
|
288
|
-
else
|
289
|
-
runner.registerError("The selected air loop with handle '#{handle}' was not found in the model. It may have been removed by another measure.")
|
290
|
-
end
|
291
|
-
return false
|
292
|
-
else
|
293
|
-
if !object.get.to_AirLoopHVAC.empty?
|
294
|
-
selected_airloop = object.get.to_AirLoopHVAC.get
|
295
|
-
elsif !object.get.to_Building.empty?
|
296
|
-
apply_to_all_air_loops = true
|
297
|
-
else
|
298
|
-
runner.registerError('Script Error - argument not showing up as air loop.')
|
299
|
-
return false
|
300
|
-
end
|
301
|
-
end # end of if object.empty?
|
302
|
-
|
303
|
-
# Add selected airloops to an array
|
304
|
-
selected_airloops = []
|
305
|
-
if apply_to_all_air_loops == true
|
306
|
-
selected_airloops = model.getAirLoopHVACs
|
307
|
-
else
|
308
|
-
selected_airloops << selected_airloop
|
309
|
-
end
|
310
|
-
|
311
|
-
# Change CAV to VAV on the selected airloops, where applicable
|
312
|
-
selected_airloops.each do |air_loop|
|
313
|
-
changed_cav_to_vav = false
|
314
|
-
|
315
|
-
# Make a new AirLoopHVAC:UnitarySystem object
|
316
|
-
air_loop_hvac_unitary_system = OpenStudio::Model::AirLoopHVACUnitarySystem.new(model)
|
317
|
-
|
318
|
-
# Find CAV fan and replace with VAV fan
|
319
|
-
air_loop.supplyComponents.each do |supply_comp|
|
320
|
-
if supply_comp.to_FanConstantVolume.is_initialized
|
321
|
-
|
322
|
-
# Preserve characteristics of the original fan
|
323
|
-
cav_fan = supply_comp.to_FanConstantVolume.get
|
324
|
-
fan_pressure_rise = cav_fan.pressureRise
|
325
|
-
fan_efficiency = cav_fan.fanEfficiency
|
326
|
-
motor_efficiency = cav_fan.motorEfficiency
|
327
|
-
fan_availability_schedule = cav_fan.availabilitySchedule
|
328
|
-
|
329
|
-
# Get the previous and next components on the loop
|
330
|
-
prev_node = cav_fan.inletModelObject.get.to_Node.get
|
331
|
-
next_node = cav_fan.outletModelObject.get.to_Node.get
|
332
|
-
|
333
|
-
# Make the new vav_fan and transfer existing parameters to it
|
334
|
-
vav_fan = OpenStudio::Model::FanVariableVolume.new(model, model.alwaysOnDiscreteSchedule)
|
335
|
-
vav_fan.setPressureRise(fan_pressure_rise)
|
336
|
-
vav_fan.setFanEfficiency(fan_efficiency)
|
337
|
-
vav_fan.setMotorEfficiency(motor_efficiency)
|
338
|
-
vav_fan.setAvailabilitySchedule(fan_availability_schedule)
|
339
|
-
|
340
|
-
# Remove the supply fan
|
341
|
-
supply_comp.remove
|
342
|
-
|
343
|
-
# Get back the remaining node
|
344
|
-
remaining_node = nil
|
345
|
-
if prev_node.outletModelObject.is_initialized
|
346
|
-
remaining_node = prev_node
|
347
|
-
elsif next_node.inletModelObject.is_initialized
|
348
|
-
remaining_node = next_node
|
349
|
-
end
|
350
|
-
|
351
|
-
# Add a new AirLoopHVAC:UnitarySystem object to the node where the old fan was
|
352
|
-
if remaining_node.nil?
|
353
|
-
runner.registerError("Couldn't add the new AirLoopHVAC:UnitarySystem object to the loop after removing existing CAV fan.")
|
354
|
-
return false
|
355
|
-
else
|
356
|
-
air_loop_hvac_unitary_system.addToNode(remaining_node)
|
357
|
-
end
|
358
|
-
|
359
|
-
# Change the unitary system control type to setpoint to enable the VAV fan to ramp down.
|
360
|
-
air_loop_hvac_unitary_system.setString(2, 'Setpoint')
|
361
|
-
|
362
|
-
# Add the VAV fan to the AirLoopHVAC:UnitarySystem object
|
363
|
-
air_loop_hvac_unitary_system.setSupplyFan(vav_fan)
|
364
|
-
|
365
|
-
# Set the AirLoopHVAC:UnitarySystem fan placement
|
366
|
-
air_loop_hvac_unitary_system.setFanPlacement('BlowThrough')
|
367
|
-
|
368
|
-
# Set the AirLoopHVAC:UnitarySystem Supply Air Fan Operating Mode Schedule
|
369
|
-
air_loop_hvac_unitary_system.setSupplyAirFanOperatingModeSchedule(model.alwaysOnDiscreteSchedule)
|
370
|
-
|
371
|
-
# let the user know that a change was made
|
372
|
-
changed_cav_to_vav = true
|
373
|
-
runner.registerInfo("AirLoop '#{air_loop.name}' was changed from CAV to VAV")
|
374
|
-
|
375
|
-
end
|
376
|
-
end # next supply component
|
377
|
-
|
378
|
-
# Move on to the next air loop if no CAV to VAV change happened
|
379
|
-
next if changed_cav_to_vav != true
|
380
|
-
|
381
|
-
# initialize COP variables to make available in both multi-speed heating and cooling coils
|
382
|
-
low_speed_cop = nil
|
383
|
-
high_speed_cop = nil
|
384
|
-
|
385
|
-
# Move the cooling coil to the AirLoopHVAC:UnitarySystem object
|
386
|
-
air_loop.supplyComponents.each do |supply_comp|
|
387
|
-
if supply_comp.to_CoilCoolingDXTwoSpeed.is_initialized
|
388
|
-
|
389
|
-
existing_cooling_coil = supply_comp.to_CoilCoolingDXTwoSpeed.get
|
390
|
-
|
391
|
-
# Add a new cooling coil object
|
392
|
-
if cooling_coil_type == 'Two-Stage Compressor'
|
393
|
-
new_cooling_coil = OpenStudio::Model::CoilCoolingDXMultiSpeed.new(model)
|
394
|
-
half_speed_cc_cop = half_cc_eer.to_f / 3.412
|
395
|
-
new_cooling_coil_data_1 = OpenStudio::Model::CoilCoolingDXMultiSpeedStageData.new(model)
|
396
|
-
new_cooling_coil_data_1.setGrossRatedCoolingCOP(half_speed_cc_cop.to_f)
|
397
|
-
rated_speed_cc_cop = rated_cc_eer.to_f / 3.412
|
398
|
-
new_cooling_coil_data_2 = OpenStudio::Model::CoilCoolingDXMultiSpeedStageData.new(model)
|
399
|
-
new_cooling_coil_data_2.setGrossRatedCoolingCOP(rated_speed_cc_cop.to_f)
|
400
|
-
new_cooling_coil.setFuelType('Electricity')
|
401
|
-
new_cooling_coil.addStage(new_cooling_coil_data_1)
|
402
|
-
new_cooling_coil.addStage(new_cooling_coil_data_2)
|
403
|
-
air_loop_hvac_unitary_system.setCoolingCoil(new_cooling_coil)
|
404
|
-
elsif cooling_coil_type == 'Four-Stage Compressor'
|
405
|
-
new_cooling_coil = OpenStudio::Model::CoilCoolingDXMultiSpeed.new(model)
|
406
|
-
quarter_speed_cc_cop = quarter_cc_eer.to_f / 3.412
|
407
|
-
new_cooling_coil_data_1 = OpenStudio::Model::CoilCoolingDXMultiSpeedStageData.new(model)
|
408
|
-
new_cooling_coil_data_1.setGrossRatedCoolingCOP(quarter_speed_cc_cop.to_f)
|
409
|
-
half_speed_cc_cop = half_cc_eer.to_f / 3.412
|
410
|
-
new_cooling_coil_data_2 = OpenStudio::Model::CoilCoolingDXMultiSpeedStageData.new(model)
|
411
|
-
new_cooling_coil_data_2.setGrossRatedCoolingCOP(half_speed_cc_cop.to_f)
|
412
|
-
three_quarter_speed_cc_cop = three_quarter_cc_eer.to_f / 3.412
|
413
|
-
new_cooling_coil_data_3 = OpenStudio::Model::CoilCoolingDXMultiSpeedStageData.new(model)
|
414
|
-
new_cooling_coil_data_3.setGrossRatedCoolingCOP(three_quarter_speed_cc_cop.to_f)
|
415
|
-
rated_speed_cc_cop = rated_cc_eer.to_f / 3.412
|
416
|
-
new_cooling_coil_data_4 = OpenStudio::Model::CoilCoolingDXMultiSpeedStageData.new(model)
|
417
|
-
new_cooling_coil_data_4.setGrossRatedCoolingCOP(rated_speed_cc_cop.to_f)
|
418
|
-
new_cooling_coil.setFuelType('Electricity')
|
419
|
-
new_cooling_coil.addStage(new_cooling_coil_data_1)
|
420
|
-
new_cooling_coil.addStage(new_cooling_coil_data_2)
|
421
|
-
new_cooling_coil.addStage(new_cooling_coil_data_3)
|
422
|
-
new_cooling_coil.addStage(new_cooling_coil_data_4)
|
423
|
-
air_loop_hvac_unitary_system.setCoolingCoil(new_cooling_coil)
|
424
|
-
end
|
425
|
-
|
426
|
-
# Remove the existing cooling coil.
|
427
|
-
existing_cooling_coil.remove
|
428
|
-
end
|
429
|
-
end # next supply component
|
430
|
-
|
431
|
-
# Move the heating coil to the AirLoopHVAC:UnitarySystem object
|
432
|
-
air_loop.supplyComponents.each do |supply_comp|
|
433
|
-
if supply_comp.to_CoilHeatingGas.is_initialized
|
434
|
-
|
435
|
-
existing_heating_coil = supply_comp.to_CoilHeatingGas.get
|
436
|
-
|
437
|
-
# Remove the existing heating coil.
|
438
|
-
existing_heating_coil.remove
|
439
|
-
|
440
|
-
# Add a new heating coil object
|
441
|
-
if heating_coil_type == 'Gas Heating Coil'
|
442
|
-
new_heating_coil = OpenStudio::Model::CoilHeatingGas.new(model)
|
443
|
-
new_heating_coil.setGasBurnerEfficiency(rated_hc_gas_efficiency.to_f)
|
444
|
-
air_loop_hvac_unitary_system.setHeatingCoil(new_heating_coil)
|
445
|
-
|
446
|
-
elsif heating_coil_type == 'Heat Pump' && cooling_coil_type == 'Two-Stage Compressor'
|
447
|
-
new_heating_coil = OpenStudio::Model::CoilHeatingDXMultiSpeed.new(model)
|
448
|
-
new_heating_coil_data_1 = OpenStudio::Model::CoilHeatingDXMultiSpeedStageData.new(model)
|
449
|
-
new_heating_coil_data_1.setGrossRatedHeatingCOP(half_hc_cop.to_f)
|
450
|
-
new_heating_coil_data_2 = OpenStudio::Model::CoilHeatingDXMultiSpeedStageData.new(model)
|
451
|
-
new_heating_coil_data_2.setGrossRatedHeatingCOP(rated_hc_cop.to_f)
|
452
|
-
new_heating_coil.setFuelType('Electricity')
|
453
|
-
new_heating_coil.addStage(new_heating_coil_data_1)
|
454
|
-
new_heating_coil.addStage(new_heating_coil_data_2)
|
455
|
-
air_loop_hvac_unitary_system.setHeatingCoil(new_heating_coil)
|
456
|
-
elsif heating_coil_type == 'Heat Pump' && cooling_coil_type == 'Four-Stage Compressor'
|
457
|
-
new_heating_coil = OpenStudio::Model::CoilHeatingDXMultiSpeed.new(model)
|
458
|
-
new_heating_coil_data_1 = OpenStudio::Model::CoilHeatingDXMultiSpeedStageData.new(model)
|
459
|
-
new_heating_coil_data_1.setGrossRatedHeatingCOP(quarter_hc_cop.to_f)
|
460
|
-
new_heating_coil_data_2 = OpenStudio::Model::CoilHeatingDXMultiSpeedStageData.new(model)
|
461
|
-
new_heating_coil_data_2.setGrossRatedHeatingCOP(half_hc_cop.to_f)
|
462
|
-
new_heating_coil_data_3 = OpenStudio::Model::CoilHeatingDXMultiSpeedStageData.new(model)
|
463
|
-
new_heating_coil_data_3.setGrossRatedHeatingCOP(three_quarter_hc_cop.to_f)
|
464
|
-
new_heating_coil_data_4 = OpenStudio::Model::CoilHeatingDXMultiSpeedStageData.new(model)
|
465
|
-
new_heating_coil_data_4.setGrossRatedHeatingCOP(rated_hc_cop.to_f)
|
466
|
-
new_heating_coil.setFuelType('Electricity')
|
467
|
-
new_heating_coil.addStage(new_heating_coil_data_1)
|
468
|
-
new_heating_coil.addStage(new_heating_coil_data_2)
|
469
|
-
new_heating_coil.addStage(new_heating_coil_data_3)
|
470
|
-
new_heating_coil.addStage(new_heating_coil_data_4)
|
471
|
-
air_loop_hvac_unitary_system.setHeatingCoil(new_heating_coil)
|
472
|
-
end
|
473
|
-
end
|
474
|
-
end # next supply component
|
475
|
-
|
476
|
-
# Find the supply outlet node for the current AirLoop
|
477
|
-
airloop_outlet_node = air_loop.supplyOutletNode
|
478
|
-
|
479
|
-
# Identify if there is a setpoint manager on the AirLoop outlet node
|
480
|
-
if !airloop_outlet_node.setpointManagers.empty?
|
481
|
-
setpoint_manager = airloop_outlet_node.setpointManagers[0]
|
482
|
-
# runner.registerInfo("Setpoint manager on node '#{airloop_outlet_node.name}' is '#{setpoint_manager.name}'.")
|
483
|
-
else
|
484
|
-
runner.registerInfo("No setpoint manager on node '#{airloop_outlet_node.name}'.")
|
485
|
-
end
|
486
|
-
|
487
|
-
# Set the controlling zone location to the zone on the airloop
|
488
|
-
air_loop.demandComponents.each do |demand_comp|
|
489
|
-
if demand_comp.to_AirTerminalSingleDuctUncontrolled.is_initialized
|
490
|
-
|
491
|
-
terminal_obj = demand_comp.to_AirTerminalSingleDuctUncontrolled.get
|
492
|
-
|
493
|
-
# Record the zone that the terminal unit is in.
|
494
|
-
# If zone cannot be determined, skip to next demand component
|
495
|
-
# and warn user that this the associated zone could not be found
|
496
|
-
term_zone = nil
|
497
|
-
model.getThermalZones.each do |zone|
|
498
|
-
zone.equipment.each do |equip|
|
499
|
-
if equip == terminal_obj
|
500
|
-
term_zone = zone
|
501
|
-
end
|
502
|
-
end
|
503
|
-
end
|
504
|
-
if term_zone.nil?
|
505
|
-
runner.registerWarning("Could not determine the zone for terminal '#{new_vav_terminal.name}', cannot assign to AirLoopHVAC:UnitarySystem object.")
|
506
|
-
next
|
507
|
-
else
|
508
|
-
# Associate the zone with the AirLoopHVAC:UnitarySystem object
|
509
|
-
air_loop_hvac_unitary_system.setControllingZoneorThermostatLocation(term_zone)
|
510
|
-
end
|
511
|
-
end
|
512
|
-
end
|
513
|
-
end # Next selected airloop
|
514
|
-
|
515
|
-
# Report final condition of model
|
516
|
-
final_cav_airloops = 0
|
517
|
-
final_vav_airloops = 0
|
518
|
-
model.getAirLoopHVACs.each do |air_loop|
|
519
|
-
# Loop through all supply components on the airloop and find CAV and VAV fans
|
520
|
-
air_loop.supplyComponents.each do |supply_comp|
|
521
|
-
if supply_comp.to_FanConstantVolume.is_initialized
|
522
|
-
final_cav_airloops += 1
|
523
|
-
elsif supply_comp.to_AirLoopHVACUnitarySystem.is_initialized
|
524
|
-
final_vav_airloops += 1
|
525
|
-
end
|
526
|
-
end
|
527
|
-
end
|
528
|
-
runner.registerFinalCondition("The building finished with #{final_cav_airloops} constant-speed RTUs and #{final_vav_airloops} multi-speed RTUs.")
|
529
|
-
|
530
|
-
if final_cav_airloops == initial_cav_airloops
|
531
|
-
runner.registerAsNotApplicable('This measure is not applicable; no variable speed RTUs were added.')
|
532
|
-
end
|
533
|
-
|
534
|
-
return true
|
535
|
-
end # end the run method
|
536
|
-
end # end the measure
|
537
|
-
|
538
|
-
# register the measure to be used by the application
|
539
|
-
CreateVariableSpeedRTU.new.registerWithApplication
|