epb_view_models 1.2.3 → 2.0.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/Gemfile +1 -1
- data/Gemfile.lock +38 -28
- data/epb_view_models.gemspec +1 -1
- data/lib/epb_view_models.rb +1 -1
- data/lib/presenter/cepc/report.rb +11 -15
- data/lib/presenter/cepc/summary.rb +5 -14
- data/lib/presenter/dec/report.rb +5 -9
- data/lib/presenter/dec/summary.rb +3 -11
- data/lib/presenter/dec/xml_summary.rb +2 -2
- data/lib/presenter/export/base.rb +4 -4
- data/lib/presenter/export/commercial.rb +16 -27
- data/lib/presenter/export/domestic.rb +30 -39
- data/lib/presenter/rd_sap/domestic_digest.rb +2 -4
- data/lib/presenter/rd_sap/report.rb +47 -57
- data/lib/presenter/rd_sap/summary.rb +13 -21
- data/lib/presenter/sap/domestic_digest.rb +2 -4
- data/lib/presenter/sap/report.rb +49 -59
- data/lib/presenter/sap/summary.rb +27 -41
- data/lib/view_model/cepc31/cepc.rb +4 -44
- data/lib/view_model/cepc31/common_schema.rb +1 -1
- data/lib/view_model/cepc31/dec.rb +14 -34
- data/lib/view_model/cepc40/ac_report.rb +1 -1
- data/lib/view_model/cepc40/cepc.rb +6 -30
- data/lib/view_model/cepc40/common_schema.rb +1 -1
- data/lib/view_model/cepc40/dec.rb +16 -16
- data/lib/view_model/cepc50/ac_report.rb +1 -1
- data/lib/view_model/cepc50/cepc.rb +6 -10
- data/lib/view_model/cepc50/common_schema.rb +1 -1
- data/lib/view_model/cepc50/dec.rb +16 -16
- data/lib/view_model/cepc51/ac_report.rb +1 -1
- data/lib/view_model/cepc51/cepc.rb +6 -6
- data/lib/view_model/cepc51/common_schema.rb +1 -1
- data/lib/view_model/cepc51/dec.rb +16 -16
- data/lib/view_model/cepc60/ac_report.rb +1 -1
- data/lib/view_model/cepc60/cepc.rb +6 -10
- data/lib/view_model/cepc60/common_schema.rb +1 -1
- data/lib/view_model/cepc60/dec.rb +17 -17
- data/lib/view_model/cepc70/ac_cert.rb +3 -3
- data/lib/view_model/cepc70/ac_report.rb +1 -1
- data/lib/view_model/cepc70/cepc.rb +6 -10
- data/lib/view_model/cepc70/common_schema.rb +1 -1
- data/lib/view_model/cepc70/dec.rb +17 -17
- data/lib/view_model/cepc71/ac_cert.rb +3 -3
- data/lib/view_model/cepc71/ac_report.rb +1 -1
- data/lib/view_model/cepc71/cepc.rb +6 -6
- data/lib/view_model/cepc71/common_schema.rb +1 -1
- data/lib/view_model/cepc71/dec.rb +17 -17
- data/lib/view_model/cepc800/ac_cert.rb +3 -3
- data/lib/view_model/cepc800/ac_report.rb +1 -1
- data/lib/view_model/cepc800/cepc.rb +6 -11
- data/lib/view_model/cepc800/common_schema.rb +1 -1
- data/lib/view_model/cepc800/dec.rb +17 -17
- data/lib/view_model/cepc_ni800/ac_cert.rb +3 -3
- data/lib/view_model/cepc_ni800/ac_report.rb +1 -1
- data/lib/view_model/cepc_ni800/cepc.rb +6 -10
- data/lib/view_model/cepc_ni800/common_schema.rb +1 -1
- data/lib/view_model/cepc_ni800/dec.rb +17 -17
- data/lib/view_model/rd_sap_schema_170/common_schema.rb +17 -25
- data/lib/view_model/rd_sap_schema_171/common_schema.rb +17 -25
- data/lib/view_model/rd_sap_schema_180/common_schema.rb +17 -25
- data/lib/view_model/rd_sap_schema_190/common_schema.rb +17 -25
- data/lib/view_model/rd_sap_schema_200/common_schema.rb +17 -25
- data/lib/view_model/rd_sap_schema_210/common_schema.rb +14 -34
- data/lib/view_model/rd_sap_schema_ni_173/common_schema.rb +17 -25
- data/lib/view_model/rd_sap_schema_ni_174/common_schema.rb +17 -25
- data/lib/view_model/rd_sap_schema_ni_180/common_schema.rb +17 -25
- data/lib/view_model/rd_sap_schema_ni_190/common_schema.rb +17 -25
- data/lib/view_model/rd_sap_schema_ni_200/common_schema.rb +17 -25
- data/lib/view_model/sap_schema_102/common_schema.rb +13 -85
- data/lib/view_model/sap_schema_102/rdsap.rb +3 -3
- data/lib/view_model/sap_schema_110/common_schema.rb +13 -65
- data/lib/view_model/sap_schema_110/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_110/sap.rb +1 -1
- data/lib/view_model/sap_schema_112/common_schema.rb +13 -65
- data/lib/view_model/sap_schema_112/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_112/sap.rb +1 -1
- data/lib/view_model/sap_schema_120/common_schema.rb +13 -61
- data/lib/view_model/sap_schema_120/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_120/sap.rb +1 -1
- data/lib/view_model/sap_schema_130/common_schema.rb +13 -61
- data/lib/view_model/sap_schema_130/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_130/sap.rb +1 -1
- data/lib/view_model/sap_schema_140/common_schema.rb +14 -58
- data/lib/view_model/sap_schema_140/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_140/sap.rb +1 -1
- data/lib/view_model/sap_schema_141/common_schema.rb +14 -58
- data/lib/view_model/sap_schema_141/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_141/sap.rb +1 -1
- data/lib/view_model/sap_schema_142/common_schema.rb +14 -58
- data/lib/view_model/sap_schema_142/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_142/sap.rb +1 -1
- data/lib/view_model/sap_schema_150/common_schema.rb +14 -58
- data/lib/view_model/sap_schema_150/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_150/sap.rb +1 -1
- data/lib/view_model/sap_schema_160/common_schema.rb +14 -58
- data/lib/view_model/sap_schema_160/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_160/sap.rb +1 -1
- data/lib/view_model/sap_schema_161/common_schema.rb +14 -58
- data/lib/view_model/sap_schema_161/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_161/sap.rb +1 -1
- data/lib/view_model/sap_schema_162/common_schema.rb +14 -58
- data/lib/view_model/sap_schema_162/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_162/sap.rb +1 -1
- data/lib/view_model/sap_schema_163/common_schema.rb +13 -53
- data/lib/view_model/sap_schema_163/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_163/sap.rb +1 -1
- data/lib/view_model/sap_schema_170/common_schema.rb +13 -65
- data/lib/view_model/sap_schema_171/common_schema.rb +13 -65
- data/lib/view_model/sap_schema_1800/common_schema.rb +12 -64
- data/lib/view_model/sap_schema_1900/common_schema.rb +10 -50
- data/lib/view_model/sap_schema_1910/common_schema.rb +10 -50
- data/lib/view_model/sap_schema_ni_112/common_schema.rb +13 -61
- data/lib/view_model/sap_schema_ni_112/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_ni_112/sap.rb +1 -1
- data/lib/view_model/sap_schema_ni_120/common_schema.rb +13 -61
- data/lib/view_model/sap_schema_ni_120/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_ni_120/sap.rb +1 -1
- data/lib/view_model/sap_schema_ni_130/common_schema.rb +13 -61
- data/lib/view_model/sap_schema_ni_130/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_ni_130/sap.rb +1 -1
- data/lib/view_model/sap_schema_ni_140/common_schema.rb +14 -58
- data/lib/view_model/sap_schema_ni_140/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_ni_140/sap.rb +1 -1
- data/lib/view_model/sap_schema_ni_141/common_schema.rb +14 -58
- data/lib/view_model/sap_schema_ni_141/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_ni_141/sap.rb +1 -1
- data/lib/view_model/sap_schema_ni_142/common_schema.rb +14 -58
- data/lib/view_model/sap_schema_ni_142/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_ni_142/sap.rb +1 -1
- data/lib/view_model/sap_schema_ni_150/common_schema.rb +14 -58
- data/lib/view_model/sap_schema_ni_150/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_ni_150/sap.rb +1 -1
- data/lib/view_model/sap_schema_ni_160/common_schema.rb +14 -54
- data/lib/view_model/sap_schema_ni_160/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_ni_160/sap.rb +1 -1
- data/lib/view_model/sap_schema_ni_161/common_schema.rb +14 -50
- data/lib/view_model/sap_schema_ni_161/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_ni_161/sap.rb +1 -1
- data/lib/view_model/sap_schema_ni_170/common_schema.rb +14 -54
- data/lib/view_model/sap_schema_ni_170/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_ni_170/sap.rb +1 -1
- data/lib/view_model/sap_schema_ni_171/common_schema.rb +14 -54
- data/lib/view_model/sap_schema_ni_171/rdsap.rb +3 -19
- data/lib/view_model/sap_schema_ni_171/sap.rb +1 -1
- data/lib/view_model/sap_schema_ni_172/common_schema.rb +14 -54
- data/lib/view_model/sap_schema_ni_172/rdsap.rb +3 -23
- data/lib/view_model/sap_schema_ni_172/sap.rb +1 -1
- data/lib/view_model/sap_schema_ni_173/common_schema.rb +10 -78
- data/lib/view_model/sap_schema_ni_174/common_schema.rb +10 -78
- data/lib/view_model/sap_schema_ni_1800/common_schema.rb +10 -78
- metadata +4 -4
|
@@ -165,11 +165,11 @@ module ViewModel
|
|
|
165
165
|
end
|
|
166
166
|
|
|
167
167
|
def potential_energy_rating
|
|
168
|
-
xpath(%w[Energy-Rating-Potential])
|
|
168
|
+
xpath(%w[Energy-Rating-Potential])&.to_i
|
|
169
169
|
end
|
|
170
170
|
|
|
171
171
|
def current_energy_rating
|
|
172
|
-
xpath(%w[Energy-Rating-Current])
|
|
172
|
+
xpath(%w[Energy-Rating-Current])&.to_i
|
|
173
173
|
end
|
|
174
174
|
|
|
175
175
|
def estimated_energy_cost; end
|
|
@@ -206,40 +206,40 @@ module ViewModel
|
|
|
206
206
|
|
|
207
207
|
def impact_of_cavity_insulation
|
|
208
208
|
if xpath(%w[Impact-Of-Cavity-Insulation])
|
|
209
|
-
xpath(%w[Impact-Of-Cavity-Insulation])
|
|
209
|
+
xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
|
|
210
210
|
end
|
|
211
211
|
end
|
|
212
212
|
|
|
213
213
|
def impact_of_loft_insulation
|
|
214
214
|
if xpath(%w[Impact-Of-Loft-Insulation])
|
|
215
|
-
xpath(%w[Impact-Of-Loft-Insulation])
|
|
215
|
+
xpath(%w[Impact-Of-Loft-Insulation])&.to_i
|
|
216
216
|
end
|
|
217
217
|
end
|
|
218
218
|
|
|
219
219
|
def impact_of_solid_wall_insulation
|
|
220
220
|
if xpath(%w[Impact-Of-Solid-Wall-Insulation])
|
|
221
|
-
xpath(%w[Impact-Of-Solid-Wall-Insulation])
|
|
221
|
+
xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
|
|
222
222
|
end
|
|
223
223
|
end
|
|
224
224
|
|
|
225
225
|
def habitable_room_count
|
|
226
|
-
xpath(%w[Habitable-Room-Count])
|
|
226
|
+
xpath(%w[Habitable-Room-Count])&.to_i
|
|
227
227
|
end
|
|
228
228
|
|
|
229
229
|
def energy_rating_current
|
|
230
|
-
xpath(%w[Energy-Rating-Current])
|
|
230
|
+
xpath(%w[Energy-Rating-Current])&.to_i
|
|
231
231
|
end
|
|
232
232
|
|
|
233
233
|
def energy_rating_potential
|
|
234
|
-
xpath(%w[Energy-Rating-Potential])
|
|
234
|
+
xpath(%w[Energy-Rating-Potential])&.to_i
|
|
235
235
|
end
|
|
236
236
|
|
|
237
237
|
def environmental_impact_current
|
|
238
|
-
xpath(%w[Environmental-Impact-Current])
|
|
238
|
+
xpath(%w[Environmental-Impact-Current])&.to_i
|
|
239
239
|
end
|
|
240
240
|
|
|
241
241
|
def environmental_impact_potential
|
|
242
|
-
xpath(%w[Environmental-Impact-Potential])
|
|
242
|
+
xpath(%w[Environmental-Impact-Potential])&.to_i
|
|
243
243
|
end
|
|
244
244
|
|
|
245
245
|
def primary_energy_use
|
|
@@ -311,7 +311,7 @@ module ViewModel
|
|
|
311
311
|
end
|
|
312
312
|
|
|
313
313
|
def storey_count
|
|
314
|
-
xpath(%w[Storey-Count])
|
|
314
|
+
xpath(%w[Storey-Count])&.to_i
|
|
315
315
|
end
|
|
316
316
|
|
|
317
317
|
def building_part_number
|
|
@@ -393,28 +393,8 @@ module ViewModel
|
|
|
393
393
|
xpath(%w[Multiple-Glazed-Proportion])
|
|
394
394
|
end
|
|
395
395
|
|
|
396
|
-
def glazed_area
|
|
397
|
-
nil
|
|
398
|
-
end
|
|
399
|
-
|
|
400
396
|
def heated_room_count
|
|
401
|
-
xpath(%w[Heated-Room-Count])
|
|
402
|
-
end
|
|
403
|
-
|
|
404
|
-
def low_energy_lighting
|
|
405
|
-
nil
|
|
406
|
-
end
|
|
407
|
-
|
|
408
|
-
def fixed_lighting_outlets_count
|
|
409
|
-
nil
|
|
410
|
-
end
|
|
411
|
-
|
|
412
|
-
def low_energy_fixed_lighting_outlets_count
|
|
413
|
-
nil
|
|
414
|
-
end
|
|
415
|
-
|
|
416
|
-
def open_fireplaces_count
|
|
417
|
-
nil
|
|
397
|
+
xpath(%w[Heated-Room-Count])&.to_i
|
|
418
398
|
end
|
|
419
399
|
|
|
420
400
|
def hot_water_description
|
|
@@ -430,7 +410,7 @@ module ViewModel
|
|
|
430
410
|
end
|
|
431
411
|
|
|
432
412
|
def wind_turbine_count
|
|
433
|
-
xpath(%w[Wind-Turbines-Count])
|
|
413
|
+
xpath(%w[Wind-Turbines-Count])&.to_i
|
|
434
414
|
end
|
|
435
415
|
|
|
436
416
|
def heat_loss_corridor
|
|
@@ -486,7 +466,7 @@ module ViewModel
|
|
|
486
466
|
end
|
|
487
467
|
|
|
488
468
|
def extensions_count
|
|
489
|
-
xpath(%w[Extensions-Count])
|
|
469
|
+
xpath(%w[Extensions-Count])&.to_i
|
|
490
470
|
end
|
|
491
471
|
|
|
492
472
|
def report_type
|
|
@@ -145,11 +145,11 @@ module ViewModel
|
|
|
145
145
|
end
|
|
146
146
|
|
|
147
147
|
def potential_energy_rating
|
|
148
|
-
xpath(%w[Energy-Rating-Potential])
|
|
148
|
+
xpath(%w[Energy-Rating-Potential])&.to_i
|
|
149
149
|
end
|
|
150
150
|
|
|
151
151
|
def current_energy_rating
|
|
152
|
-
xpath(%w[Energy-Rating-Current])
|
|
152
|
+
xpath(%w[Energy-Rating-Current])&.to_i
|
|
153
153
|
end
|
|
154
154
|
|
|
155
155
|
def estimated_energy_cost; end
|
|
@@ -194,40 +194,40 @@ module ViewModel
|
|
|
194
194
|
|
|
195
195
|
def impact_of_cavity_insulation
|
|
196
196
|
if xpath(%w[Impact-Of-Cavity-Insulation])
|
|
197
|
-
xpath(%w[Impact-Of-Cavity-Insulation])
|
|
197
|
+
xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
|
|
198
198
|
end
|
|
199
199
|
end
|
|
200
200
|
|
|
201
201
|
def impact_of_loft_insulation
|
|
202
202
|
if xpath(%w[Impact-Of-Loft-Insulation])
|
|
203
|
-
xpath(%w[Impact-Of-Loft-Insulation])
|
|
203
|
+
xpath(%w[Impact-Of-Loft-Insulation])&.to_i
|
|
204
204
|
end
|
|
205
205
|
end
|
|
206
206
|
|
|
207
207
|
def impact_of_solid_wall_insulation
|
|
208
208
|
if xpath(%w[Impact-Of-Solid-Wall-Insulation])
|
|
209
|
-
xpath(%w[Impact-Of-Solid-Wall-Insulation])
|
|
209
|
+
xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
|
|
210
210
|
end
|
|
211
211
|
end
|
|
212
212
|
|
|
213
213
|
def habitable_room_count
|
|
214
|
-
xpath(%w[Habitable-Room-Count])
|
|
214
|
+
xpath(%w[Habitable-Room-Count])&.to_i
|
|
215
215
|
end
|
|
216
216
|
|
|
217
217
|
def energy_rating_current
|
|
218
|
-
xpath(%w[Energy-Rating-Current])
|
|
218
|
+
xpath(%w[Energy-Rating-Current])&.to_i
|
|
219
219
|
end
|
|
220
220
|
|
|
221
221
|
def energy_rating_potential
|
|
222
|
-
xpath(%w[Energy-Rating-Potential])
|
|
222
|
+
xpath(%w[Energy-Rating-Potential])&.to_i
|
|
223
223
|
end
|
|
224
224
|
|
|
225
225
|
def environmental_impact_current
|
|
226
|
-
xpath(%w[Environmental-Impact-Current])
|
|
226
|
+
xpath(%w[Environmental-Impact-Current])&.to_i
|
|
227
227
|
end
|
|
228
228
|
|
|
229
229
|
def environmental_impact_potential
|
|
230
|
-
xpath(%w[Environmental-Impact-Potential])
|
|
230
|
+
xpath(%w[Environmental-Impact-Potential])&.to_i
|
|
231
231
|
end
|
|
232
232
|
|
|
233
233
|
def primary_energy_use
|
|
@@ -309,7 +309,7 @@ module ViewModel
|
|
|
309
309
|
end
|
|
310
310
|
|
|
311
311
|
def storey_count
|
|
312
|
-
xpath(%w[Storey-Count])
|
|
312
|
+
xpath(%w[Storey-Count])&.to_i
|
|
313
313
|
end
|
|
314
314
|
|
|
315
315
|
def main_heating_controls
|
|
@@ -325,7 +325,7 @@ module ViewModel
|
|
|
325
325
|
end
|
|
326
326
|
|
|
327
327
|
def heated_room_count
|
|
328
|
-
xpath(%w[Heated-Room-Count])
|
|
328
|
+
xpath(%w[Heated-Room-Count])&.to_i
|
|
329
329
|
end
|
|
330
330
|
|
|
331
331
|
def low_energy_lighting
|
|
@@ -333,15 +333,15 @@ module ViewModel
|
|
|
333
333
|
end
|
|
334
334
|
|
|
335
335
|
def fixed_lighting_outlets_count
|
|
336
|
-
xpath(%w[Fixed-Lighting-Outlets-Count])
|
|
336
|
+
xpath(%w[Fixed-Lighting-Outlets-Count])&.to_i
|
|
337
337
|
end
|
|
338
338
|
|
|
339
339
|
def low_energy_fixed_lighting_outlets_count
|
|
340
|
-
xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])
|
|
340
|
+
xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])&.to_i
|
|
341
341
|
end
|
|
342
342
|
|
|
343
343
|
def open_fireplaces_count
|
|
344
|
-
xpath(%w[Open-Fireplaces-Count])
|
|
344
|
+
xpath(%w[Open-Fireplaces-Count])&.to_i
|
|
345
345
|
end
|
|
346
346
|
|
|
347
347
|
def hot_water_description
|
|
@@ -357,7 +357,7 @@ module ViewModel
|
|
|
357
357
|
end
|
|
358
358
|
|
|
359
359
|
def wind_turbine_count
|
|
360
|
-
xpath(%w[Wind-Turbines-Count])
|
|
360
|
+
xpath(%w[Wind-Turbines-Count])&.to_i
|
|
361
361
|
end
|
|
362
362
|
|
|
363
363
|
def heat_loss_corridor
|
|
@@ -413,7 +413,7 @@ module ViewModel
|
|
|
413
413
|
end
|
|
414
414
|
|
|
415
415
|
def extensions_count
|
|
416
|
-
xpath(%w[Extensions-Count])
|
|
416
|
+
xpath(%w[Extensions-Count])&.to_i
|
|
417
417
|
end
|
|
418
418
|
|
|
419
419
|
def report_type
|
|
@@ -517,14 +517,6 @@ module ViewModel
|
|
|
517
517
|
def has_cylinder_thermostat
|
|
518
518
|
xpath(%w[Cylinder-Thermostat])
|
|
519
519
|
end
|
|
520
|
-
|
|
521
|
-
def gas_smart_meter_present
|
|
522
|
-
nil
|
|
523
|
-
end
|
|
524
|
-
|
|
525
|
-
def electricity_smart_meter_present
|
|
526
|
-
nil
|
|
527
|
-
end
|
|
528
520
|
end
|
|
529
521
|
end
|
|
530
522
|
end
|
|
@@ -145,11 +145,11 @@ module ViewModel
|
|
|
145
145
|
end
|
|
146
146
|
|
|
147
147
|
def potential_energy_rating
|
|
148
|
-
xpath(%w[Energy-Rating-Potential])
|
|
148
|
+
xpath(%w[Energy-Rating-Potential])&.to_i
|
|
149
149
|
end
|
|
150
150
|
|
|
151
151
|
def current_energy_rating
|
|
152
|
-
xpath(%w[Energy-Rating-Current])
|
|
152
|
+
xpath(%w[Energy-Rating-Current])&.to_i
|
|
153
153
|
end
|
|
154
154
|
|
|
155
155
|
def estimated_energy_cost; end
|
|
@@ -186,40 +186,40 @@ module ViewModel
|
|
|
186
186
|
|
|
187
187
|
def impact_of_cavity_insulation
|
|
188
188
|
if xpath(%w[Impact-Of-Cavity-Insulation])
|
|
189
|
-
xpath(%w[Impact-Of-Cavity-Insulation])
|
|
189
|
+
xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
|
|
190
190
|
end
|
|
191
191
|
end
|
|
192
192
|
|
|
193
193
|
def impact_of_loft_insulation
|
|
194
194
|
if xpath(%w[Impact-Of-Loft-Insulation])
|
|
195
|
-
xpath(%w[Impact-Of-Loft-Insulation])
|
|
195
|
+
xpath(%w[Impact-Of-Loft-Insulation])&.to_i
|
|
196
196
|
end
|
|
197
197
|
end
|
|
198
198
|
|
|
199
199
|
def impact_of_solid_wall_insulation
|
|
200
200
|
if xpath(%w[Impact-Of-Solid-Wall-Insulation])
|
|
201
|
-
xpath(%w[Impact-Of-Solid-Wall-Insulation])
|
|
201
|
+
xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
|
|
202
202
|
end
|
|
203
203
|
end
|
|
204
204
|
|
|
205
205
|
def habitable_room_count
|
|
206
|
-
xpath(%w[Habitable-Room-Count])
|
|
206
|
+
xpath(%w[Habitable-Room-Count])&.to_i
|
|
207
207
|
end
|
|
208
208
|
|
|
209
209
|
def energy_rating_current
|
|
210
|
-
xpath(%w[Energy-Rating-Current])
|
|
210
|
+
xpath(%w[Energy-Rating-Current])&.to_i
|
|
211
211
|
end
|
|
212
212
|
|
|
213
213
|
def energy_rating_potential
|
|
214
|
-
xpath(%w[Energy-Rating-Potential])
|
|
214
|
+
xpath(%w[Energy-Rating-Potential])&.to_i
|
|
215
215
|
end
|
|
216
216
|
|
|
217
217
|
def environmental_impact_current
|
|
218
|
-
xpath(%w[Environmental-Impact-Current])
|
|
218
|
+
xpath(%w[Environmental-Impact-Current])&.to_i
|
|
219
219
|
end
|
|
220
220
|
|
|
221
221
|
def environmental_impact_potential
|
|
222
|
-
xpath(%w[Environmental-Impact-Potential])
|
|
222
|
+
xpath(%w[Environmental-Impact-Potential])&.to_i
|
|
223
223
|
end
|
|
224
224
|
|
|
225
225
|
def primary_energy_use
|
|
@@ -309,7 +309,7 @@ module ViewModel
|
|
|
309
309
|
end
|
|
310
310
|
|
|
311
311
|
def storey_count
|
|
312
|
-
xpath(%w[Storey-Count])
|
|
312
|
+
xpath(%w[Storey-Count])&.to_i
|
|
313
313
|
end
|
|
314
314
|
|
|
315
315
|
def main_heating_controls
|
|
@@ -325,7 +325,7 @@ module ViewModel
|
|
|
325
325
|
end
|
|
326
326
|
|
|
327
327
|
def heated_room_count
|
|
328
|
-
xpath(%w[Heated-Room-Count])
|
|
328
|
+
xpath(%w[Heated-Room-Count])&.to_i
|
|
329
329
|
end
|
|
330
330
|
|
|
331
331
|
def low_energy_lighting
|
|
@@ -333,15 +333,15 @@ module ViewModel
|
|
|
333
333
|
end
|
|
334
334
|
|
|
335
335
|
def fixed_lighting_outlets_count
|
|
336
|
-
xpath(%w[Fixed-Lighting-Outlets-Count])
|
|
336
|
+
xpath(%w[Fixed-Lighting-Outlets-Count])&.to_i
|
|
337
337
|
end
|
|
338
338
|
|
|
339
339
|
def low_energy_fixed_lighting_outlets_count
|
|
340
|
-
xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])
|
|
340
|
+
xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])&.to_i
|
|
341
341
|
end
|
|
342
342
|
|
|
343
343
|
def open_fireplaces_count
|
|
344
|
-
xpath(%w[Open-Fireplaces-Count])
|
|
344
|
+
xpath(%w[Open-Fireplaces-Count])&.to_i
|
|
345
345
|
end
|
|
346
346
|
|
|
347
347
|
def hot_water_description
|
|
@@ -357,7 +357,7 @@ module ViewModel
|
|
|
357
357
|
end
|
|
358
358
|
|
|
359
359
|
def wind_turbine_count
|
|
360
|
-
xpath(%w[Wind-Turbines-Count])
|
|
360
|
+
xpath(%w[Wind-Turbines-Count])&.to_i
|
|
361
361
|
end
|
|
362
362
|
|
|
363
363
|
def heat_loss_corridor
|
|
@@ -413,7 +413,7 @@ module ViewModel
|
|
|
413
413
|
end
|
|
414
414
|
|
|
415
415
|
def extensions_count
|
|
416
|
-
xpath(%w[Extensions-Count])
|
|
416
|
+
xpath(%w[Extensions-Count])&.to_i
|
|
417
417
|
end
|
|
418
418
|
|
|
419
419
|
def report_type
|
|
@@ -517,14 +517,6 @@ module ViewModel
|
|
|
517
517
|
def has_cylinder_thermostat
|
|
518
518
|
xpath(%w[Cylinder-Thermostat])
|
|
519
519
|
end
|
|
520
|
-
|
|
521
|
-
def gas_smart_meter_present
|
|
522
|
-
nil
|
|
523
|
-
end
|
|
524
|
-
|
|
525
|
-
def electricity_smart_meter_present
|
|
526
|
-
nil
|
|
527
|
-
end
|
|
528
520
|
end
|
|
529
521
|
end
|
|
530
522
|
end
|
|
@@ -145,11 +145,11 @@ module ViewModel
|
|
|
145
145
|
end
|
|
146
146
|
|
|
147
147
|
def potential_energy_rating
|
|
148
|
-
xpath(%w[Energy-Rating-Potential])
|
|
148
|
+
xpath(%w[Energy-Rating-Potential])&.to_i
|
|
149
149
|
end
|
|
150
150
|
|
|
151
151
|
def current_energy_rating
|
|
152
|
-
xpath(%w[Energy-Rating-Current])
|
|
152
|
+
xpath(%w[Energy-Rating-Current])&.to_i
|
|
153
153
|
end
|
|
154
154
|
|
|
155
155
|
def estimated_energy_cost; end
|
|
@@ -186,40 +186,40 @@ module ViewModel
|
|
|
186
186
|
|
|
187
187
|
def impact_of_cavity_insulation
|
|
188
188
|
if xpath(%w[Impact-Of-Cavity-Insulation])
|
|
189
|
-
xpath(%w[Impact-Of-Cavity-Insulation])
|
|
189
|
+
xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
|
|
190
190
|
end
|
|
191
191
|
end
|
|
192
192
|
|
|
193
193
|
def impact_of_loft_insulation
|
|
194
194
|
if xpath(%w[Impact-Of-Loft-Insulation])
|
|
195
|
-
xpath(%w[Impact-Of-Loft-Insulation])
|
|
195
|
+
xpath(%w[Impact-Of-Loft-Insulation])&.to_i
|
|
196
196
|
end
|
|
197
197
|
end
|
|
198
198
|
|
|
199
199
|
def impact_of_solid_wall_insulation
|
|
200
200
|
if xpath(%w[Impact-Of-Solid-Wall-Insulation])
|
|
201
|
-
xpath(%w[Impact-Of-Solid-Wall-Insulation])
|
|
201
|
+
xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
|
|
202
202
|
end
|
|
203
203
|
end
|
|
204
204
|
|
|
205
205
|
def habitable_room_count
|
|
206
|
-
xpath(%w[Habitable-Room-Count])
|
|
206
|
+
xpath(%w[Habitable-Room-Count])&.to_i
|
|
207
207
|
end
|
|
208
208
|
|
|
209
209
|
def energy_rating_current
|
|
210
|
-
xpath(%w[Energy-Rating-Current])
|
|
210
|
+
xpath(%w[Energy-Rating-Current])&.to_i
|
|
211
211
|
end
|
|
212
212
|
|
|
213
213
|
def energy_rating_potential
|
|
214
|
-
xpath(%w[Energy-Rating-Potential])
|
|
214
|
+
xpath(%w[Energy-Rating-Potential])&.to_i
|
|
215
215
|
end
|
|
216
216
|
|
|
217
217
|
def environmental_impact_current
|
|
218
|
-
xpath(%w[Environmental-Impact-Current])
|
|
218
|
+
xpath(%w[Environmental-Impact-Current])&.to_i
|
|
219
219
|
end
|
|
220
220
|
|
|
221
221
|
def environmental_impact_potential
|
|
222
|
-
xpath(%w[Environmental-Impact-Potential])
|
|
222
|
+
xpath(%w[Environmental-Impact-Potential])&.to_i
|
|
223
223
|
end
|
|
224
224
|
|
|
225
225
|
def primary_energy_use
|
|
@@ -309,7 +309,7 @@ module ViewModel
|
|
|
309
309
|
end
|
|
310
310
|
|
|
311
311
|
def storey_count
|
|
312
|
-
xpath(%w[Storey-Count])
|
|
312
|
+
xpath(%w[Storey-Count])&.to_i
|
|
313
313
|
end
|
|
314
314
|
|
|
315
315
|
def main_heating_controls
|
|
@@ -325,7 +325,7 @@ module ViewModel
|
|
|
325
325
|
end
|
|
326
326
|
|
|
327
327
|
def heated_room_count
|
|
328
|
-
xpath(%w[Heated-Room-Count])
|
|
328
|
+
xpath(%w[Heated-Room-Count])&.to_i
|
|
329
329
|
end
|
|
330
330
|
|
|
331
331
|
def low_energy_lighting
|
|
@@ -333,15 +333,15 @@ module ViewModel
|
|
|
333
333
|
end
|
|
334
334
|
|
|
335
335
|
def fixed_lighting_outlets_count
|
|
336
|
-
xpath(%w[Fixed-Lighting-Outlets-Count])
|
|
336
|
+
xpath(%w[Fixed-Lighting-Outlets-Count])&.to_i
|
|
337
337
|
end
|
|
338
338
|
|
|
339
339
|
def low_energy_fixed_lighting_outlets_count
|
|
340
|
-
xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])
|
|
340
|
+
xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])&.to_i
|
|
341
341
|
end
|
|
342
342
|
|
|
343
343
|
def open_fireplaces_count
|
|
344
|
-
xpath(%w[Open-Fireplaces-Count])
|
|
344
|
+
xpath(%w[Open-Fireplaces-Count])&.to_i
|
|
345
345
|
end
|
|
346
346
|
|
|
347
347
|
def hot_water_description
|
|
@@ -357,7 +357,7 @@ module ViewModel
|
|
|
357
357
|
end
|
|
358
358
|
|
|
359
359
|
def wind_turbine_count
|
|
360
|
-
xpath(%w[Wind-Turbines-Count])
|
|
360
|
+
xpath(%w[Wind-Turbines-Count])&.to_i
|
|
361
361
|
end
|
|
362
362
|
|
|
363
363
|
def heat_loss_corridor
|
|
@@ -413,7 +413,7 @@ module ViewModel
|
|
|
413
413
|
end
|
|
414
414
|
|
|
415
415
|
def extensions_count
|
|
416
|
-
xpath(%w[Extensions-Count])
|
|
416
|
+
xpath(%w[Extensions-Count])&.to_i
|
|
417
417
|
end
|
|
418
418
|
|
|
419
419
|
def report_type
|
|
@@ -517,14 +517,6 @@ module ViewModel
|
|
|
517
517
|
def has_cylinder_thermostat
|
|
518
518
|
xpath(%w[Cylinder-Thermostat])
|
|
519
519
|
end
|
|
520
|
-
|
|
521
|
-
def gas_smart_meter_present
|
|
522
|
-
nil
|
|
523
|
-
end
|
|
524
|
-
|
|
525
|
-
def electricity_smart_meter_present
|
|
526
|
-
nil
|
|
527
|
-
end
|
|
528
520
|
end
|
|
529
521
|
end
|
|
530
522
|
end
|
|
@@ -145,11 +145,11 @@ module ViewModel
|
|
|
145
145
|
end
|
|
146
146
|
|
|
147
147
|
def potential_energy_rating
|
|
148
|
-
xpath(%w[Energy-Rating-Potential])
|
|
148
|
+
xpath(%w[Energy-Rating-Potential])&.to_i
|
|
149
149
|
end
|
|
150
150
|
|
|
151
151
|
def current_energy_rating
|
|
152
|
-
xpath(%w[Energy-Rating-Current])
|
|
152
|
+
xpath(%w[Energy-Rating-Current])&.to_i
|
|
153
153
|
end
|
|
154
154
|
|
|
155
155
|
def estimated_energy_cost; end
|
|
@@ -186,40 +186,40 @@ module ViewModel
|
|
|
186
186
|
|
|
187
187
|
def impact_of_cavity_insulation
|
|
188
188
|
if xpath(%w[Impact-Of-Cavity-Insulation])
|
|
189
|
-
xpath(%w[Impact-Of-Cavity-Insulation])
|
|
189
|
+
xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
|
|
190
190
|
end
|
|
191
191
|
end
|
|
192
192
|
|
|
193
193
|
def impact_of_loft_insulation
|
|
194
194
|
if xpath(%w[Impact-Of-Loft-Insulation])
|
|
195
|
-
xpath(%w[Impact-Of-Loft-Insulation])
|
|
195
|
+
xpath(%w[Impact-Of-Loft-Insulation])&.to_i
|
|
196
196
|
end
|
|
197
197
|
end
|
|
198
198
|
|
|
199
199
|
def impact_of_solid_wall_insulation
|
|
200
200
|
if xpath(%w[Impact-Of-Solid-Wall-Insulation])
|
|
201
|
-
xpath(%w[Impact-Of-Solid-Wall-Insulation])
|
|
201
|
+
xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
|
|
202
202
|
end
|
|
203
203
|
end
|
|
204
204
|
|
|
205
205
|
def habitable_room_count
|
|
206
|
-
xpath(%w[Habitable-Room-Count])
|
|
206
|
+
xpath(%w[Habitable-Room-Count])&.to_i
|
|
207
207
|
end
|
|
208
208
|
|
|
209
209
|
def energy_rating_current
|
|
210
|
-
xpath(%w[Energy-Rating-Current])
|
|
210
|
+
xpath(%w[Energy-Rating-Current])&.to_i
|
|
211
211
|
end
|
|
212
212
|
|
|
213
213
|
def energy_rating_potential
|
|
214
|
-
xpath(%w[Energy-Rating-Potential])
|
|
214
|
+
xpath(%w[Energy-Rating-Potential])&.to_i
|
|
215
215
|
end
|
|
216
216
|
|
|
217
217
|
def environmental_impact_current
|
|
218
|
-
xpath(%w[Environmental-Impact-Current])
|
|
218
|
+
xpath(%w[Environmental-Impact-Current])&.to_i
|
|
219
219
|
end
|
|
220
220
|
|
|
221
221
|
def environmental_impact_potential
|
|
222
|
-
xpath(%w[Environmental-Impact-Potential])
|
|
222
|
+
xpath(%w[Environmental-Impact-Potential])&.to_i
|
|
223
223
|
end
|
|
224
224
|
|
|
225
225
|
def primary_energy_use
|
|
@@ -309,7 +309,7 @@ module ViewModel
|
|
|
309
309
|
end
|
|
310
310
|
|
|
311
311
|
def storey_count
|
|
312
|
-
xpath(%w[Storey-Count])
|
|
312
|
+
xpath(%w[Storey-Count])&.to_i
|
|
313
313
|
end
|
|
314
314
|
|
|
315
315
|
def main_heating_controls
|
|
@@ -325,7 +325,7 @@ module ViewModel
|
|
|
325
325
|
end
|
|
326
326
|
|
|
327
327
|
def heated_room_count
|
|
328
|
-
xpath(%w[Heated-Room-Count])
|
|
328
|
+
xpath(%w[Heated-Room-Count])&.to_i
|
|
329
329
|
end
|
|
330
330
|
|
|
331
331
|
def low_energy_lighting
|
|
@@ -333,15 +333,15 @@ module ViewModel
|
|
|
333
333
|
end
|
|
334
334
|
|
|
335
335
|
def fixed_lighting_outlets_count
|
|
336
|
-
xpath(%w[Fixed-Lighting-Outlets-Count])
|
|
336
|
+
xpath(%w[Fixed-Lighting-Outlets-Count])&.to_i
|
|
337
337
|
end
|
|
338
338
|
|
|
339
339
|
def low_energy_fixed_lighting_outlets_count
|
|
340
|
-
xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])
|
|
340
|
+
xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])&.to_i
|
|
341
341
|
end
|
|
342
342
|
|
|
343
343
|
def open_fireplaces_count
|
|
344
|
-
xpath(%w[Open-Fireplaces-Count])
|
|
344
|
+
xpath(%w[Open-Fireplaces-Count])&.to_i
|
|
345
345
|
end
|
|
346
346
|
|
|
347
347
|
def hot_water_description
|
|
@@ -357,7 +357,7 @@ module ViewModel
|
|
|
357
357
|
end
|
|
358
358
|
|
|
359
359
|
def wind_turbine_count
|
|
360
|
-
xpath(%w[Wind-Turbines-Count])
|
|
360
|
+
xpath(%w[Wind-Turbines-Count])&.to_i
|
|
361
361
|
end
|
|
362
362
|
|
|
363
363
|
def heat_loss_corridor
|
|
@@ -413,7 +413,7 @@ module ViewModel
|
|
|
413
413
|
end
|
|
414
414
|
|
|
415
415
|
def extensions_count
|
|
416
|
-
xpath(%w[Extensions-Count])
|
|
416
|
+
xpath(%w[Extensions-Count])&.to_i
|
|
417
417
|
end
|
|
418
418
|
|
|
419
419
|
def report_type
|
|
@@ -517,14 +517,6 @@ module ViewModel
|
|
|
517
517
|
def has_cylinder_thermostat
|
|
518
518
|
xpath(%w[Cylinder-Thermostat])
|
|
519
519
|
end
|
|
520
|
-
|
|
521
|
-
def gas_smart_meter_present
|
|
522
|
-
nil
|
|
523
|
-
end
|
|
524
|
-
|
|
525
|
-
def electricity_smart_meter_present
|
|
526
|
-
nil
|
|
527
|
-
end
|
|
528
520
|
end
|
|
529
521
|
end
|
|
530
522
|
end
|