epb_view_models 1.2.3 → 2.0.0

Sign up to get free protection for your applications and to get access to all the features.
Files changed (152) hide show
  1. checksums.yaml +4 -4
  2. data/Gemfile +1 -1
  3. data/Gemfile.lock +38 -28
  4. data/epb_view_models.gemspec +1 -1
  5. data/lib/epb_view_models.rb +1 -1
  6. data/lib/presenter/cepc/report.rb +11 -15
  7. data/lib/presenter/cepc/summary.rb +5 -14
  8. data/lib/presenter/dec/report.rb +5 -9
  9. data/lib/presenter/dec/summary.rb +3 -11
  10. data/lib/presenter/dec/xml_summary.rb +2 -2
  11. data/lib/presenter/export/base.rb +4 -4
  12. data/lib/presenter/export/commercial.rb +16 -27
  13. data/lib/presenter/export/domestic.rb +30 -39
  14. data/lib/presenter/rd_sap/domestic_digest.rb +2 -4
  15. data/lib/presenter/rd_sap/report.rb +47 -57
  16. data/lib/presenter/rd_sap/summary.rb +13 -21
  17. data/lib/presenter/sap/domestic_digest.rb +2 -4
  18. data/lib/presenter/sap/report.rb +49 -59
  19. data/lib/presenter/sap/summary.rb +27 -41
  20. data/lib/view_model/cepc31/cepc.rb +4 -44
  21. data/lib/view_model/cepc31/common_schema.rb +1 -1
  22. data/lib/view_model/cepc31/dec.rb +14 -34
  23. data/lib/view_model/cepc40/ac_report.rb +1 -1
  24. data/lib/view_model/cepc40/cepc.rb +6 -30
  25. data/lib/view_model/cepc40/common_schema.rb +1 -1
  26. data/lib/view_model/cepc40/dec.rb +16 -16
  27. data/lib/view_model/cepc50/ac_report.rb +1 -1
  28. data/lib/view_model/cepc50/cepc.rb +6 -10
  29. data/lib/view_model/cepc50/common_schema.rb +1 -1
  30. data/lib/view_model/cepc50/dec.rb +16 -16
  31. data/lib/view_model/cepc51/ac_report.rb +1 -1
  32. data/lib/view_model/cepc51/cepc.rb +6 -6
  33. data/lib/view_model/cepc51/common_schema.rb +1 -1
  34. data/lib/view_model/cepc51/dec.rb +16 -16
  35. data/lib/view_model/cepc60/ac_report.rb +1 -1
  36. data/lib/view_model/cepc60/cepc.rb +6 -10
  37. data/lib/view_model/cepc60/common_schema.rb +1 -1
  38. data/lib/view_model/cepc60/dec.rb +17 -17
  39. data/lib/view_model/cepc70/ac_cert.rb +3 -3
  40. data/lib/view_model/cepc70/ac_report.rb +1 -1
  41. data/lib/view_model/cepc70/cepc.rb +6 -10
  42. data/lib/view_model/cepc70/common_schema.rb +1 -1
  43. data/lib/view_model/cepc70/dec.rb +17 -17
  44. data/lib/view_model/cepc71/ac_cert.rb +3 -3
  45. data/lib/view_model/cepc71/ac_report.rb +1 -1
  46. data/lib/view_model/cepc71/cepc.rb +6 -6
  47. data/lib/view_model/cepc71/common_schema.rb +1 -1
  48. data/lib/view_model/cepc71/dec.rb +17 -17
  49. data/lib/view_model/cepc800/ac_cert.rb +3 -3
  50. data/lib/view_model/cepc800/ac_report.rb +1 -1
  51. data/lib/view_model/cepc800/cepc.rb +6 -11
  52. data/lib/view_model/cepc800/common_schema.rb +1 -1
  53. data/lib/view_model/cepc800/dec.rb +17 -17
  54. data/lib/view_model/cepc_ni800/ac_cert.rb +3 -3
  55. data/lib/view_model/cepc_ni800/ac_report.rb +1 -1
  56. data/lib/view_model/cepc_ni800/cepc.rb +6 -10
  57. data/lib/view_model/cepc_ni800/common_schema.rb +1 -1
  58. data/lib/view_model/cepc_ni800/dec.rb +17 -17
  59. data/lib/view_model/rd_sap_schema_170/common_schema.rb +17 -25
  60. data/lib/view_model/rd_sap_schema_171/common_schema.rb +17 -25
  61. data/lib/view_model/rd_sap_schema_180/common_schema.rb +17 -25
  62. data/lib/view_model/rd_sap_schema_190/common_schema.rb +17 -25
  63. data/lib/view_model/rd_sap_schema_200/common_schema.rb +17 -25
  64. data/lib/view_model/rd_sap_schema_210/common_schema.rb +14 -34
  65. data/lib/view_model/rd_sap_schema_ni_173/common_schema.rb +17 -25
  66. data/lib/view_model/rd_sap_schema_ni_174/common_schema.rb +17 -25
  67. data/lib/view_model/rd_sap_schema_ni_180/common_schema.rb +17 -25
  68. data/lib/view_model/rd_sap_schema_ni_190/common_schema.rb +17 -25
  69. data/lib/view_model/rd_sap_schema_ni_200/common_schema.rb +17 -25
  70. data/lib/view_model/sap_schema_102/common_schema.rb +13 -85
  71. data/lib/view_model/sap_schema_102/rdsap.rb +3 -3
  72. data/lib/view_model/sap_schema_110/common_schema.rb +13 -65
  73. data/lib/view_model/sap_schema_110/rdsap.rb +3 -19
  74. data/lib/view_model/sap_schema_110/sap.rb +1 -1
  75. data/lib/view_model/sap_schema_112/common_schema.rb +13 -65
  76. data/lib/view_model/sap_schema_112/rdsap.rb +3 -19
  77. data/lib/view_model/sap_schema_112/sap.rb +1 -1
  78. data/lib/view_model/sap_schema_120/common_schema.rb +13 -61
  79. data/lib/view_model/sap_schema_120/rdsap.rb +3 -19
  80. data/lib/view_model/sap_schema_120/sap.rb +1 -1
  81. data/lib/view_model/sap_schema_130/common_schema.rb +13 -61
  82. data/lib/view_model/sap_schema_130/rdsap.rb +3 -19
  83. data/lib/view_model/sap_schema_130/sap.rb +1 -1
  84. data/lib/view_model/sap_schema_140/common_schema.rb +14 -58
  85. data/lib/view_model/sap_schema_140/rdsap.rb +3 -19
  86. data/lib/view_model/sap_schema_140/sap.rb +1 -1
  87. data/lib/view_model/sap_schema_141/common_schema.rb +14 -58
  88. data/lib/view_model/sap_schema_141/rdsap.rb +3 -19
  89. data/lib/view_model/sap_schema_141/sap.rb +1 -1
  90. data/lib/view_model/sap_schema_142/common_schema.rb +14 -58
  91. data/lib/view_model/sap_schema_142/rdsap.rb +3 -19
  92. data/lib/view_model/sap_schema_142/sap.rb +1 -1
  93. data/lib/view_model/sap_schema_150/common_schema.rb +14 -58
  94. data/lib/view_model/sap_schema_150/rdsap.rb +3 -19
  95. data/lib/view_model/sap_schema_150/sap.rb +1 -1
  96. data/lib/view_model/sap_schema_160/common_schema.rb +14 -58
  97. data/lib/view_model/sap_schema_160/rdsap.rb +3 -19
  98. data/lib/view_model/sap_schema_160/sap.rb +1 -1
  99. data/lib/view_model/sap_schema_161/common_schema.rb +14 -58
  100. data/lib/view_model/sap_schema_161/rdsap.rb +3 -19
  101. data/lib/view_model/sap_schema_161/sap.rb +1 -1
  102. data/lib/view_model/sap_schema_162/common_schema.rb +14 -58
  103. data/lib/view_model/sap_schema_162/rdsap.rb +3 -19
  104. data/lib/view_model/sap_schema_162/sap.rb +1 -1
  105. data/lib/view_model/sap_schema_163/common_schema.rb +13 -53
  106. data/lib/view_model/sap_schema_163/rdsap.rb +3 -19
  107. data/lib/view_model/sap_schema_163/sap.rb +1 -1
  108. data/lib/view_model/sap_schema_170/common_schema.rb +13 -65
  109. data/lib/view_model/sap_schema_171/common_schema.rb +13 -65
  110. data/lib/view_model/sap_schema_1800/common_schema.rb +12 -64
  111. data/lib/view_model/sap_schema_1900/common_schema.rb +10 -50
  112. data/lib/view_model/sap_schema_1910/common_schema.rb +10 -50
  113. data/lib/view_model/sap_schema_ni_112/common_schema.rb +13 -61
  114. data/lib/view_model/sap_schema_ni_112/rdsap.rb +3 -19
  115. data/lib/view_model/sap_schema_ni_112/sap.rb +1 -1
  116. data/lib/view_model/sap_schema_ni_120/common_schema.rb +13 -61
  117. data/lib/view_model/sap_schema_ni_120/rdsap.rb +3 -19
  118. data/lib/view_model/sap_schema_ni_120/sap.rb +1 -1
  119. data/lib/view_model/sap_schema_ni_130/common_schema.rb +13 -61
  120. data/lib/view_model/sap_schema_ni_130/rdsap.rb +3 -19
  121. data/lib/view_model/sap_schema_ni_130/sap.rb +1 -1
  122. data/lib/view_model/sap_schema_ni_140/common_schema.rb +14 -58
  123. data/lib/view_model/sap_schema_ni_140/rdsap.rb +3 -19
  124. data/lib/view_model/sap_schema_ni_140/sap.rb +1 -1
  125. data/lib/view_model/sap_schema_ni_141/common_schema.rb +14 -58
  126. data/lib/view_model/sap_schema_ni_141/rdsap.rb +3 -19
  127. data/lib/view_model/sap_schema_ni_141/sap.rb +1 -1
  128. data/lib/view_model/sap_schema_ni_142/common_schema.rb +14 -58
  129. data/lib/view_model/sap_schema_ni_142/rdsap.rb +3 -19
  130. data/lib/view_model/sap_schema_ni_142/sap.rb +1 -1
  131. data/lib/view_model/sap_schema_ni_150/common_schema.rb +14 -58
  132. data/lib/view_model/sap_schema_ni_150/rdsap.rb +3 -19
  133. data/lib/view_model/sap_schema_ni_150/sap.rb +1 -1
  134. data/lib/view_model/sap_schema_ni_160/common_schema.rb +14 -54
  135. data/lib/view_model/sap_schema_ni_160/rdsap.rb +3 -19
  136. data/lib/view_model/sap_schema_ni_160/sap.rb +1 -1
  137. data/lib/view_model/sap_schema_ni_161/common_schema.rb +14 -50
  138. data/lib/view_model/sap_schema_ni_161/rdsap.rb +3 -19
  139. data/lib/view_model/sap_schema_ni_161/sap.rb +1 -1
  140. data/lib/view_model/sap_schema_ni_170/common_schema.rb +14 -54
  141. data/lib/view_model/sap_schema_ni_170/rdsap.rb +3 -19
  142. data/lib/view_model/sap_schema_ni_170/sap.rb +1 -1
  143. data/lib/view_model/sap_schema_ni_171/common_schema.rb +14 -54
  144. data/lib/view_model/sap_schema_ni_171/rdsap.rb +3 -19
  145. data/lib/view_model/sap_schema_ni_171/sap.rb +1 -1
  146. data/lib/view_model/sap_schema_ni_172/common_schema.rb +14 -54
  147. data/lib/view_model/sap_schema_ni_172/rdsap.rb +3 -23
  148. data/lib/view_model/sap_schema_ni_172/sap.rb +1 -1
  149. data/lib/view_model/sap_schema_ni_173/common_schema.rb +10 -78
  150. data/lib/view_model/sap_schema_ni_174/common_schema.rb +10 -78
  151. data/lib/view_model/sap_schema_ni_1800/common_schema.rb +10 -78
  152. metadata +4 -4
@@ -160,11 +160,11 @@ module ViewModel
160
160
  end
161
161
 
162
162
  def potential_energy_rating
163
- xpath(%w[Energy-Rating-Potential]).to_i
163
+ xpath(%w[Energy-Rating-Potential])&.to_i
164
164
  end
165
165
 
166
166
  def current_energy_rating
167
- xpath(%w[Energy-Rating-Current]).to_i
167
+ xpath(%w[Energy-Rating-Current])&.to_i
168
168
  end
169
169
 
170
170
  def estimated_energy_cost; end
@@ -201,40 +201,40 @@ module ViewModel
201
201
 
202
202
  def impact_of_cavity_insulation
203
203
  if xpath(%w[Impact-Of-Cavity-Insulation])
204
- xpath(%w[Impact-Of-Cavity-Insulation]).to_i
204
+ xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
205
205
  end
206
206
  end
207
207
 
208
208
  def impact_of_loft_insulation
209
209
  if xpath(%w[Impact-Of-Loft-Insulation])
210
- xpath(%w[Impact-Of-Loft-Insulation]).to_i
210
+ xpath(%w[Impact-Of-Loft-Insulation])&.to_i
211
211
  end
212
212
  end
213
213
 
214
214
  def impact_of_solid_wall_insulation
215
215
  if xpath(%w[Impact-Of-Solid-Wall-Insulation])
216
- xpath(%w[Impact-Of-Solid-Wall-Insulation]).to_i
216
+ xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
217
217
  end
218
218
  end
219
219
 
220
220
  def habitable_room_count
221
- xpath(%w[Habitable-Room-Count])
221
+ xpath(%w[Habitable-Room-Count])&.to_i
222
222
  end
223
223
 
224
224
  def energy_rating_current
225
- xpath(%w[Energy-Rating-Current])
225
+ xpath(%w[Energy-Rating-Current])&.to_i
226
226
  end
227
227
 
228
228
  def energy_rating_potential
229
- xpath(%w[Energy-Rating-Potential])
229
+ xpath(%w[Energy-Rating-Potential])&.to_i
230
230
  end
231
231
 
232
232
  def environmental_impact_current
233
- xpath(%w[Environmental-Impact-Current])
233
+ xpath(%w[Environmental-Impact-Current])&.to_i
234
234
  end
235
235
 
236
236
  def environmental_impact_potential
237
- xpath(%w[Environmental-Impact-Potential])
237
+ xpath(%w[Environmental-Impact-Potential])&.to_i
238
238
  end
239
239
 
240
240
  def primary_energy_use
@@ -328,7 +328,7 @@ module ViewModel
328
328
  end
329
329
 
330
330
  def storey_count
331
- xpath(%w[Storey-Count])
331
+ xpath(%w[Storey-Count])&.to_i
332
332
  end
333
333
 
334
334
  def main_heating_controls
@@ -344,7 +344,7 @@ module ViewModel
344
344
  end
345
345
 
346
346
  def heated_room_count
347
- xpath(%w[Heated-Room-Count])
347
+ xpath(%w[Heated-Room-Count])&.to_i
348
348
  end
349
349
 
350
350
  def low_energy_lighting
@@ -352,15 +352,15 @@ module ViewModel
352
352
  end
353
353
 
354
354
  def fixed_lighting_outlets_count
355
- xpath(%w[Fixed-Lighting-Outlets-Count])
355
+ xpath(%w[Fixed-Lighting-Outlets-Count])&.to_i
356
356
  end
357
357
 
358
358
  def low_energy_fixed_lighting_outlets_count
359
- xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])
359
+ xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])&.to_i
360
360
  end
361
361
 
362
362
  def open_fireplaces_count
363
- xpath(%w[Open-Fireplaces-Count])
363
+ xpath(%w[Open-Fireplaces-Count])&.to_i
364
364
  end
365
365
 
366
366
  def hot_water_description
@@ -376,7 +376,7 @@ module ViewModel
376
376
  end
377
377
 
378
378
  def wind_turbine_count
379
- xpath(%w[Wind-Turbines-Count])
379
+ xpath(%w[Wind-Turbines-Count])&.to_i
380
380
  end
381
381
 
382
382
  def heat_loss_corridor
@@ -432,7 +432,7 @@ module ViewModel
432
432
  end
433
433
 
434
434
  def extensions_count
435
- xpath(%w[Extensions-Count])
435
+ xpath(%w[Extensions-Count])&.to_i
436
436
  end
437
437
 
438
438
  def report_type
@@ -528,14 +528,6 @@ module ViewModel
528
528
  def has_cylinder_thermostat
529
529
  xpath(%w[Cylinder-Thermostat])
530
530
  end
531
-
532
- def gas_smart_meter_present
533
- nil
534
- end
535
-
536
- def electricity_smart_meter_present
537
- nil
538
- end
539
531
  end
540
532
  end
541
533
  end
@@ -160,11 +160,11 @@ module ViewModel
160
160
  end
161
161
 
162
162
  def potential_energy_rating
163
- xpath(%w[Energy-Rating-Potential]).to_i
163
+ xpath(%w[Energy-Rating-Potential])&.to_i
164
164
  end
165
165
 
166
166
  def current_energy_rating
167
- xpath(%w[Energy-Rating-Current]).to_i
167
+ xpath(%w[Energy-Rating-Current])&.to_i
168
168
  end
169
169
 
170
170
  def estimated_energy_cost; end
@@ -201,40 +201,40 @@ module ViewModel
201
201
 
202
202
  def impact_of_cavity_insulation
203
203
  if xpath(%w[Impact-Of-Cavity-Insulation])
204
- xpath(%w[Impact-Of-Cavity-Insulation]).to_i
204
+ xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
205
205
  end
206
206
  end
207
207
 
208
208
  def impact_of_loft_insulation
209
209
  if xpath(%w[Impact-Of-Loft-Insulation])
210
- xpath(%w[Impact-Of-Loft-Insulation]).to_i
210
+ xpath(%w[Impact-Of-Loft-Insulation])&.to_i
211
211
  end
212
212
  end
213
213
 
214
214
  def impact_of_solid_wall_insulation
215
215
  if xpath(%w[Impact-Of-Solid-Wall-Insulation])
216
- xpath(%w[Impact-Of-Solid-Wall-Insulation]).to_i
216
+ xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
217
217
  end
218
218
  end
219
219
 
220
220
  def habitable_room_count
221
- xpath(%w[Habitable-Room-Count])
221
+ xpath(%w[Habitable-Room-Count])&.to_i
222
222
  end
223
223
 
224
224
  def energy_rating_current
225
- xpath(%w[Energy-Rating-Current])
225
+ xpath(%w[Energy-Rating-Current])&.to_i
226
226
  end
227
227
 
228
228
  def energy_rating_potential
229
- xpath(%w[Energy-Rating-Potential])
229
+ xpath(%w[Energy-Rating-Potential])&.to_i
230
230
  end
231
231
 
232
232
  def environmental_impact_current
233
- xpath(%w[Environmental-Impact-Current])
233
+ xpath(%w[Environmental-Impact-Current])&.to_i
234
234
  end
235
235
 
236
236
  def environmental_impact_potential
237
- xpath(%w[Environmental-Impact-Potential])
237
+ xpath(%w[Environmental-Impact-Potential])&.to_i
238
238
  end
239
239
 
240
240
  def primary_energy_use
@@ -324,7 +324,7 @@ module ViewModel
324
324
  end
325
325
 
326
326
  def storey_count
327
- xpath(%w[Storey-Count])
327
+ xpath(%w[Storey-Count])&.to_i
328
328
  end
329
329
 
330
330
  def main_heating_controls
@@ -340,7 +340,7 @@ module ViewModel
340
340
  end
341
341
 
342
342
  def heated_room_count
343
- xpath(%w[Heated-Room-Count])
343
+ xpath(%w[Heated-Room-Count])&.to_i
344
344
  end
345
345
 
346
346
  def low_energy_lighting
@@ -348,15 +348,15 @@ module ViewModel
348
348
  end
349
349
 
350
350
  def fixed_lighting_outlets_count
351
- xpath(%w[Fixed-Lighting-Outlets-Count])
351
+ xpath(%w[Fixed-Lighting-Outlets-Count])&.to_i
352
352
  end
353
353
 
354
354
  def low_energy_fixed_lighting_outlets_count
355
- xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])
355
+ xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])&.to_i
356
356
  end
357
357
 
358
358
  def open_fireplaces_count
359
- xpath(%w[Open-Fireplaces-Count])
359
+ xpath(%w[Open-Fireplaces-Count])&.to_i
360
360
  end
361
361
 
362
362
  def hot_water_description
@@ -372,7 +372,7 @@ module ViewModel
372
372
  end
373
373
 
374
374
  def wind_turbine_count
375
- xpath(%w[Wind-Turbines-Count])
375
+ xpath(%w[Wind-Turbines-Count])&.to_i
376
376
  end
377
377
 
378
378
  def heat_loss_corridor
@@ -428,7 +428,7 @@ module ViewModel
428
428
  end
429
429
 
430
430
  def extensions_count
431
- xpath(%w[Extensions-Count])
431
+ xpath(%w[Extensions-Count])&.to_i
432
432
  end
433
433
 
434
434
  def report_type
@@ -528,14 +528,6 @@ module ViewModel
528
528
  def has_cylinder_thermostat
529
529
  xpath(%w[Cylinder-Thermostat])
530
530
  end
531
-
532
- def gas_smart_meter_present
533
- nil
534
- end
535
-
536
- def electricity_smart_meter_present
537
- nil
538
- end
539
531
  end
540
532
  end
541
533
  end
@@ -160,11 +160,11 @@ module ViewModel
160
160
  end
161
161
 
162
162
  def potential_energy_rating
163
- xpath(%w[Energy-Rating-Potential]).to_i
163
+ xpath(%w[Energy-Rating-Potential])&.to_i
164
164
  end
165
165
 
166
166
  def current_energy_rating
167
- xpath(%w[Energy-Rating-Current]).to_i
167
+ xpath(%w[Energy-Rating-Current])&.to_i
168
168
  end
169
169
 
170
170
  def estimated_energy_cost; end
@@ -201,40 +201,40 @@ module ViewModel
201
201
 
202
202
  def impact_of_cavity_insulation
203
203
  if xpath(%w[Impact-Of-Cavity-Insulation])
204
- xpath(%w[Impact-Of-Cavity-Insulation]).to_i
204
+ xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
205
205
  end
206
206
  end
207
207
 
208
208
  def impact_of_loft_insulation
209
209
  if xpath(%w[Impact-Of-Loft-Insulation])
210
- xpath(%w[Impact-Of-Loft-Insulation]).to_i
210
+ xpath(%w[Impact-Of-Loft-Insulation])&.to_i
211
211
  end
212
212
  end
213
213
 
214
214
  def impact_of_solid_wall_insulation
215
215
  if xpath(%w[Impact-Of-Solid-Wall-Insulation])
216
- xpath(%w[Impact-Of-Solid-Wall-Insulation]).to_i
216
+ xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
217
217
  end
218
218
  end
219
219
 
220
220
  def habitable_room_count
221
- xpath(%w[Habitable-Room-Count])
221
+ xpath(%w[Habitable-Room-Count])&.to_i
222
222
  end
223
223
 
224
224
  def energy_rating_current
225
- xpath(%w[Energy-Rating-Current])
225
+ xpath(%w[Energy-Rating-Current])&.to_i
226
226
  end
227
227
 
228
228
  def energy_rating_potential
229
- xpath(%w[Energy-Rating-Potential])
229
+ xpath(%w[Energy-Rating-Potential])&.to_i
230
230
  end
231
231
 
232
232
  def environmental_impact_current
233
- xpath(%w[Environmental-Impact-Current])
233
+ xpath(%w[Environmental-Impact-Current])&.to_i
234
234
  end
235
235
 
236
236
  def environmental_impact_potential
237
- xpath(%w[Environmental-Impact-Potential])
237
+ xpath(%w[Environmental-Impact-Potential])&.to_i
238
238
  end
239
239
 
240
240
  def primary_energy_use
@@ -314,7 +314,7 @@ module ViewModel
314
314
  end
315
315
 
316
316
  def storey_count
317
- xpath(%w[Storey-Count])
317
+ xpath(%w[Storey-Count])&.to_i
318
318
  end
319
319
 
320
320
  def main_heating_controls
@@ -330,7 +330,7 @@ module ViewModel
330
330
  end
331
331
 
332
332
  def heated_room_count
333
- xpath(%w[Heated-Room-Count])
333
+ xpath(%w[Heated-Room-Count])&.to_i
334
334
  end
335
335
 
336
336
  def low_energy_lighting
@@ -338,15 +338,15 @@ module ViewModel
338
338
  end
339
339
 
340
340
  def fixed_lighting_outlets_count
341
- xpath(%w[Fixed-Lighting-Outlets-Count])
341
+ xpath(%w[Fixed-Lighting-Outlets-Count])&.to_i
342
342
  end
343
343
 
344
344
  def low_energy_fixed_lighting_outlets_count
345
- xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])
345
+ xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])&.to_i
346
346
  end
347
347
 
348
348
  def open_fireplaces_count
349
- xpath(%w[Open-Fireplaces-Count])
349
+ xpath(%w[Open-Fireplaces-Count])&.to_i
350
350
  end
351
351
 
352
352
  def hot_water_description
@@ -372,7 +372,7 @@ module ViewModel
372
372
  end
373
373
 
374
374
  def wind_turbine_count
375
- xpath(%w[Wind-Turbines-Count])
375
+ xpath(%w[Wind-Turbines-Count])&.to_i
376
376
  end
377
377
 
378
378
  def heat_loss_corridor
@@ -428,7 +428,7 @@ module ViewModel
428
428
  end
429
429
 
430
430
  def extensions_count
431
- xpath(%w[Extensions-Count])
431
+ xpath(%w[Extensions-Count])&.to_i
432
432
  end
433
433
 
434
434
  def report_type
@@ -528,14 +528,6 @@ module ViewModel
528
528
  def has_cylinder_thermostat
529
529
  xpath(%w[Cylinder-Thermostat])
530
530
  end
531
-
532
- def gas_smart_meter_present
533
- nil
534
- end
535
-
536
- def electricity_smart_meter_present
537
- nil
538
- end
539
531
  end
540
532
  end
541
533
  end
@@ -160,11 +160,11 @@ module ViewModel
160
160
  end
161
161
 
162
162
  def potential_energy_rating
163
- xpath(%w[Energy-Rating-Potential]).to_i
163
+ xpath(%w[Energy-Rating-Potential])&.to_i
164
164
  end
165
165
 
166
166
  def current_energy_rating
167
- xpath(%w[Energy-Rating-Current]).to_i
167
+ xpath(%w[Energy-Rating-Current])&.to_i
168
168
  end
169
169
 
170
170
  def estimated_energy_cost; end
@@ -201,40 +201,40 @@ module ViewModel
201
201
 
202
202
  def impact_of_cavity_insulation
203
203
  if xpath(%w[Impact-Of-Cavity-Insulation])
204
- xpath(%w[Impact-Of-Cavity-Insulation]).to_i
204
+ xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
205
205
  end
206
206
  end
207
207
 
208
208
  def impact_of_loft_insulation
209
209
  if xpath(%w[Impact-Of-Loft-Insulation])
210
- xpath(%w[Impact-Of-Loft-Insulation]).to_i
210
+ xpath(%w[Impact-Of-Loft-Insulation])&.to_i
211
211
  end
212
212
  end
213
213
 
214
214
  def impact_of_solid_wall_insulation
215
215
  if xpath(%w[Impact-Of-Solid-Wall-Insulation])
216
- xpath(%w[Impact-Of-Solid-Wall-Insulation]).to_i
216
+ xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
217
217
  end
218
218
  end
219
219
 
220
220
  def habitable_room_count
221
- xpath(%w[Habitable-Room-Count])
221
+ xpath(%w[Habitable-Room-Count])&.to_i
222
222
  end
223
223
 
224
224
  def energy_rating_current
225
- xpath(%w[Energy-Rating-Current])
225
+ xpath(%w[Energy-Rating-Current])&.to_i
226
226
  end
227
227
 
228
228
  def energy_rating_potential
229
- xpath(%w[Energy-Rating-Potential])
229
+ xpath(%w[Energy-Rating-Potential])&.to_i
230
230
  end
231
231
 
232
232
  def environmental_impact_current
233
- xpath(%w[Environmental-Impact-Current])
233
+ xpath(%w[Environmental-Impact-Current])&.to_i
234
234
  end
235
235
 
236
236
  def environmental_impact_potential
237
- xpath(%w[Environmental-Impact-Potential])
237
+ xpath(%w[Environmental-Impact-Potential])&.to_i
238
238
  end
239
239
 
240
240
  def primary_energy_use
@@ -324,7 +324,7 @@ module ViewModel
324
324
  end
325
325
 
326
326
  def storey_count
327
- xpath(%w[Storey-Count])
327
+ xpath(%w[Storey-Count])&.to_i
328
328
  end
329
329
 
330
330
  def main_heating_controls
@@ -340,7 +340,7 @@ module ViewModel
340
340
  end
341
341
 
342
342
  def heated_room_count
343
- xpath(%w[Heated-Room-Count])
343
+ xpath(%w[Heated-Room-Count])&.to_i
344
344
  end
345
345
 
346
346
  def low_energy_lighting
@@ -348,15 +348,15 @@ module ViewModel
348
348
  end
349
349
 
350
350
  def fixed_lighting_outlets_count
351
- xpath(%w[Fixed-Lighting-Outlets-Count])
351
+ xpath(%w[Fixed-Lighting-Outlets-Count])&.to_i
352
352
  end
353
353
 
354
354
  def low_energy_fixed_lighting_outlets_count
355
- xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])
355
+ xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])&.to_i
356
356
  end
357
357
 
358
358
  def open_fireplaces_count
359
- xpath(%w[Open-Fireplaces-Count])
359
+ xpath(%w[Open-Fireplaces-Count])&.to_i
360
360
  end
361
361
 
362
362
  def hot_water_description
@@ -372,7 +372,7 @@ module ViewModel
372
372
  end
373
373
 
374
374
  def wind_turbine_count
375
- xpath(%w[Wind-Turbines-Count])
375
+ xpath(%w[Wind-Turbines-Count])&.to_i
376
376
  end
377
377
 
378
378
  def heat_loss_corridor
@@ -428,7 +428,7 @@ module ViewModel
428
428
  end
429
429
 
430
430
  def extensions_count
431
- xpath(%w[Extensions-Count])
431
+ xpath(%w[Extensions-Count])&.to_i
432
432
  end
433
433
 
434
434
  def report_type
@@ -528,14 +528,6 @@ module ViewModel
528
528
  def has_cylinder_thermostat
529
529
  xpath(%w[Cylinder-Thermostat])
530
530
  end
531
-
532
- def gas_smart_meter_present
533
- nil
534
- end
535
-
536
- def electricity_smart_meter_present
537
- nil
538
- end
539
531
  end
540
532
  end
541
533
  end
@@ -165,11 +165,11 @@ module ViewModel
165
165
  end
166
166
 
167
167
  def potential_energy_rating
168
- xpath(%w[Energy-Rating-Potential]).to_i
168
+ xpath(%w[Energy-Rating-Potential])&.to_i
169
169
  end
170
170
 
171
171
  def current_energy_rating
172
- xpath(%w[Energy-Rating-Current]).to_i
172
+ xpath(%w[Energy-Rating-Current])&.to_i
173
173
  end
174
174
 
175
175
  def estimated_energy_cost; end
@@ -206,40 +206,40 @@ module ViewModel
206
206
 
207
207
  def impact_of_cavity_insulation
208
208
  if xpath(%w[Impact-Of-Cavity-Insulation])
209
- xpath(%w[Impact-Of-Cavity-Insulation]).to_i
209
+ xpath(%w[Impact-Of-Cavity-Insulation])&.to_i
210
210
  end
211
211
  end
212
212
 
213
213
  def impact_of_loft_insulation
214
214
  if xpath(%w[Impact-Of-Loft-Insulation])
215
- xpath(%w[Impact-Of-Loft-Insulation]).to_i
215
+ xpath(%w[Impact-Of-Loft-Insulation])&.to_i
216
216
  end
217
217
  end
218
218
 
219
219
  def impact_of_solid_wall_insulation
220
220
  if xpath(%w[Impact-Of-Solid-Wall-Insulation])
221
- xpath(%w[Impact-Of-Solid-Wall-Insulation]).to_i
221
+ xpath(%w[Impact-Of-Solid-Wall-Insulation])&.to_i
222
222
  end
223
223
  end
224
224
 
225
225
  def habitable_room_count
226
- xpath(%w[Habitable-Room-Count])
226
+ xpath(%w[Habitable-Room-Count])&.to_i
227
227
  end
228
228
 
229
229
  def energy_rating_current
230
- xpath(%w[Energy-Rating-Current])
230
+ xpath(%w[Energy-Rating-Current])&.to_i
231
231
  end
232
232
 
233
233
  def energy_rating_potential
234
- xpath(%w[Energy-Rating-Potential])
234
+ xpath(%w[Energy-Rating-Potential])&.to_i
235
235
  end
236
236
 
237
237
  def environmental_impact_current
238
- xpath(%w[Environmental-Impact-Current])
238
+ xpath(%w[Environmental-Impact-Current])&.to_i
239
239
  end
240
240
 
241
241
  def environmental_impact_potential
242
- xpath(%w[Environmental-Impact-Potential])
242
+ xpath(%w[Environmental-Impact-Potential])&.to_i
243
243
  end
244
244
 
245
245
  def primary_energy_use
@@ -311,7 +311,7 @@ module ViewModel
311
311
  end
312
312
 
313
313
  def storey_count
314
- xpath(%w[Storey-Count])
314
+ xpath(%w[Storey-Count])&.to_i
315
315
  end
316
316
 
317
317
  def building_part_number
@@ -398,7 +398,7 @@ module ViewModel
398
398
  end
399
399
 
400
400
  def heated_room_count
401
- xpath(%w[Heated-Room-Count])
401
+ xpath(%w[Heated-Room-Count])&.to_i
402
402
  end
403
403
 
404
404
  def low_energy_lighting
@@ -406,15 +406,15 @@ module ViewModel
406
406
  end
407
407
 
408
408
  def fixed_lighting_outlets_count
409
- xpath(%w[Fixed-Lighting-Outlets-Count])
409
+ xpath(%w[Fixed-Lighting-Outlets-Count])&.to_i
410
410
  end
411
411
 
412
412
  def low_energy_fixed_lighting_outlets_count
413
- xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])
413
+ xpath(%w[Low-Energy-Fixed-Lighting-Outlets-Count])&.to_i
414
414
  end
415
415
 
416
416
  def open_fireplaces_count
417
- xpath(%w[Open-Fireplaces-Count])
417
+ xpath(%w[Open-Fireplaces-Count])&.to_i
418
418
  end
419
419
 
420
420
  def hot_water_description
@@ -430,7 +430,7 @@ module ViewModel
430
430
  end
431
431
 
432
432
  def wind_turbine_count
433
- xpath(%w[Wind-Turbines-Count])
433
+ xpath(%w[Wind-Turbines-Count])&.to_i
434
434
  end
435
435
 
436
436
  def heat_loss_corridor
@@ -486,7 +486,7 @@ module ViewModel
486
486
  end
487
487
 
488
488
  def extensions_count
489
- xpath(%w[Extensions-Count])
489
+ xpath(%w[Extensions-Count])&.to_i
490
490
  end
491
491
 
492
492
  def report_type
@@ -582,14 +582,6 @@ module ViewModel
582
582
  def has_cylinder_thermostat
583
583
  xpath(%w[Cylinder-Thermostat])
584
584
  end
585
-
586
- def gas_smart_meter_present
587
- nil
588
- end
589
-
590
- def electricity_smart_meter_present
591
- nil
592
- end
593
585
  end
594
586
  end
595
587
  end