zwave-js-server-python 0.31.0__py3-none-any.whl → 0.32.0__py3-none-any.whl
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- zwave_js_server/client.py +2 -0
- zwave_js_server/const/__init__.py +23 -2
- zwave_js_server/const/command_class/barrier_operator.py +2 -0
- zwave_js_server/const/command_class/lock.py +4 -0
- zwave_js_server/const/command_class/meter.py +27 -0
- zwave_js_server/const/command_class/multilevel_sensor.py +509 -349
- zwave_js_server/const/command_class/notification.py +3 -0
- zwave_js_server/const/command_class/protection.py +4 -0
- zwave_js_server/const/command_class/sound_switch.py +4 -0
- zwave_js_server/dump.py +1 -1
- zwave_js_server/model/controller.py +263 -34
- zwave_js_server/model/log_config.py +1 -1
- zwave_js_server/model/log_message.py +91 -0
- zwave_js_server/model/node.py +8 -0
- zwave_js_server/model/utils.py +13 -0
- {zwave_js_server_python-0.31.0.dist-info → zwave_js_server_python-0.32.0.dist-info}/METADATA +2 -1
- {zwave_js_server_python-0.31.0.dist-info → zwave_js_server_python-0.32.0.dist-info}/RECORD +21 -18
- {zwave_js_server_python-0.31.0.dist-info → zwave_js_server_python-0.32.0.dist-info}/LICENSE +0 -0
- {zwave_js_server_python-0.31.0.dist-info → zwave_js_server_python-0.32.0.dist-info}/WHEEL +0 -0
- {zwave_js_server_python-0.31.0.dist-info → zwave_js_server_python-0.32.0.dist-info}/entry_points.txt +0 -0
- {zwave_js_server_python-0.31.0.dist-info → zwave_js_server_python-0.32.0.dist-info}/top_level.txt +0 -0
zwave_js_server/client.py
CHANGED
|
@@ -2,18 +2,23 @@
|
|
|
2
2
|
from enum import Enum, IntEnum
|
|
3
3
|
|
|
4
4
|
# minimal server schema version we can handle
|
|
5
|
-
MIN_SERVER_SCHEMA_VERSION =
|
|
5
|
+
MIN_SERVER_SCHEMA_VERSION = 11
|
|
6
6
|
# max server schema version we can handle (and our code is compatible with)
|
|
7
|
-
MAX_SERVER_SCHEMA_VERSION =
|
|
7
|
+
MAX_SERVER_SCHEMA_VERSION = 11
|
|
8
8
|
|
|
9
9
|
VALUE_UNKNOWN = "unknown"
|
|
10
10
|
|
|
11
11
|
INTERVIEW_FAILED = "Failed"
|
|
12
12
|
|
|
13
|
+
CURRENT_STATE_PROPERTY = "currentState"
|
|
13
14
|
TARGET_STATE_PROPERTY = "targetState"
|
|
15
|
+
CURRENT_VALUE_PROPERTY = "currentValue"
|
|
14
16
|
TARGET_VALUE_PROPERTY = "targetValue"
|
|
15
17
|
DURATION_PROPERTY = "duration"
|
|
16
18
|
|
|
19
|
+
TRANSITION_DURATION_OPTION = "transitionDuration"
|
|
20
|
+
VOLUME_OPTION = "volume"
|
|
21
|
+
|
|
17
22
|
|
|
18
23
|
class CommandStatus(str, Enum):
|
|
19
24
|
"""Status of a command sent to zwave-js-server."""
|
|
@@ -216,3 +221,19 @@ class SecurityClass(IntEnum):
|
|
|
216
221
|
S2_AUTHENTICATED = 1
|
|
217
222
|
S2_ACCESS_CONTROL = 2
|
|
218
223
|
S0_LEGACY = 7
|
|
224
|
+
|
|
225
|
+
|
|
226
|
+
class QRCodeVersion(IntEnum):
|
|
227
|
+
"""Enum for all known QR Code versions."""
|
|
228
|
+
|
|
229
|
+
# https://github.com/zwave-js/node-zwave-js/blob/master/packages/core/src/security/QR.ts#L43-L46
|
|
230
|
+
S2 = 0
|
|
231
|
+
SMART_START = 1
|
|
232
|
+
|
|
233
|
+
|
|
234
|
+
class Protocols(IntEnum):
|
|
235
|
+
"""Enum for all known protocols."""
|
|
236
|
+
|
|
237
|
+
# https://github.com/zwave-js/node-zwave-js/blob/master/packages/core/src/capabilities/Protocols.ts#L1-L4
|
|
238
|
+
ZWAVE = 0
|
|
239
|
+
ZWAVE_LONG_RANGE = 1
|
|
@@ -46,6 +46,10 @@ LOCK_CMD_CLASS_TO_PROPERTY_MAP = {
|
|
|
46
46
|
|
|
47
47
|
LOCK_USERCODE_PROPERTY = "userCode"
|
|
48
48
|
LOCK_USERCODE_STATUS_PROPERTY = "userIdStatus"
|
|
49
|
+
DOOR_STATUS_PROPERTY = "doorStatus"
|
|
50
|
+
CURRENT_MODE_PROPERTY = "currentMode"
|
|
51
|
+
LOCKED_PROPERTY = "locked"
|
|
52
|
+
|
|
49
53
|
ATTR_CODE_SLOT = "code_slot"
|
|
50
54
|
ATTR_IN_USE = "in_use"
|
|
51
55
|
ATTR_NAME = "name"
|
|
@@ -2,6 +2,8 @@
|
|
|
2
2
|
from enum import IntEnum
|
|
3
3
|
from typing import Dict, Set, Type, Union
|
|
4
4
|
|
|
5
|
+
VALUE_PROPERTY = "value"
|
|
6
|
+
|
|
5
7
|
CC_SPECIFIC_SCALE = "scale"
|
|
6
8
|
CC_SPECIFIC_METER_TYPE = "meterType"
|
|
7
9
|
CC_SPECIFIC_RATE_TYPE = "rateType"
|
|
@@ -100,3 +102,28 @@ WATER_METER_TYPES: Set[MeterScaleType] = {
|
|
|
100
102
|
WaterScale.US_GALLON,
|
|
101
103
|
WaterScale.PULSE_COUNT,
|
|
102
104
|
}
|
|
105
|
+
|
|
106
|
+
UNIT_KILOWATT_HOUR: Set[MeterScaleType] = {
|
|
107
|
+
ElectricScale.KILOWATT_HOUR,
|
|
108
|
+
HeatingScale.KILOWATT_HOUR,
|
|
109
|
+
CoolingScale.KILOWATT_HOUR,
|
|
110
|
+
}
|
|
111
|
+
UNIT_KILOVOLT_AMPERE_HOUR: Set[MeterScaleType] = {ElectricScale.KILOVOLT_AMPERE_HOUR}
|
|
112
|
+
UNIT_WATT: Set[MeterScaleType] = {ElectricScale.WATT}
|
|
113
|
+
UNIT_PULSE_COUNT: Set[MeterScaleType] = {
|
|
114
|
+
ElectricScale.PULSE_COUNT,
|
|
115
|
+
GasScale.PULSE_COUNT,
|
|
116
|
+
WaterScale.PULSE_COUNT,
|
|
117
|
+
}
|
|
118
|
+
UNIT_VOLT: Set[MeterScaleType] = {ElectricScale.VOLT}
|
|
119
|
+
UNIT_AMPERE: Set[MeterScaleType] = {ElectricScale.AMPERE}
|
|
120
|
+
UNIT_POWER_FACTOR: Set[MeterScaleType] = {ElectricScale.POWER_FACTOR}
|
|
121
|
+
UNIT_KILOVOLT_AMPERE_REACTIVE: Set[MeterScaleType] = {
|
|
122
|
+
ElectricScale.KILOVOLT_AMPERE_REACTIVE
|
|
123
|
+
}
|
|
124
|
+
UNIT_KILOVOLT_AMPERE_REACTIVE_HOUR: Set[MeterScaleType] = {
|
|
125
|
+
ElectricScale.KILOVOLT_AMPERE_REACTIVE_HOUR
|
|
126
|
+
}
|
|
127
|
+
UNIT_CUBIC_METER: Set[MeterScaleType] = {GasScale.CUBIC_METER, WaterScale.CUBIC_METER}
|
|
128
|
+
UNIT_CUBIC_FEET: Set[MeterScaleType] = {GasScale.CUBIC_FEET, WaterScale.CUBIC_FEET}
|
|
129
|
+
UNIT_US_GALLON: Set[MeterScaleType] = {WaterScale.US_GALLON}
|