svkt 0.1.0__py3-none-any.whl
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- svkt/__init__.py +226 -0
- svkt/_clock.py +237 -0
- svkt/_core.py +1916 -0
- svkt/_discovery.py +308 -0
- svkt/_encode.py +540 -0
- svkt/_lock.py +152 -0
- svkt/_logging.py +54 -0
- svkt/_proto.py +179 -0
- svkt/_save.py +456 -0
- svkt/_server.py +702 -0
- svkt/_sysinfo.py +310 -0
- svkt/_wsgi.py +118 -0
- svkt-0.1.0.dist-info/METADATA +312 -0
- svkt-0.1.0.dist-info/RECORD +17 -0
- svkt-0.1.0.dist-info/WHEEL +5 -0
- svkt-0.1.0.dist-info/licenses/LICENSE +21 -0
- svkt-0.1.0.dist-info/top_level.txt +1 -0
svkt/__init__.py
ADDED
|
@@ -0,0 +1,226 @@
|
|
|
1
|
+
"""SVKT pure-Python producer client.
|
|
2
|
+
|
|
3
|
+
Records zones, instants, counters, messages, frames and program-flow arrows
|
|
4
|
+
into shared multi-tier in-memory history, streams them live to an SVKT viewer
|
|
5
|
+
over TCP (docs/PROTOCOL.md) and saves snapshots as ``.svkt`` or Chrome Trace
|
|
6
|
+
Event JSON. Standard library only, Python >= 3.8.
|
|
7
|
+
|
|
8
|
+
Quick start::
|
|
9
|
+
|
|
10
|
+
import svkt
|
|
11
|
+
svkt.init(process_name="my_service")
|
|
12
|
+
|
|
13
|
+
with svkt.zone("load", path=p) as z:
|
|
14
|
+
data = load(p)
|
|
15
|
+
z.arg("bytes", len(data))
|
|
16
|
+
|
|
17
|
+
@svkt.traced
|
|
18
|
+
async def handle(req): ...
|
|
19
|
+
|
|
20
|
+
Everything is a cheap no-op before :func:`init` and after :func:`shutdown`.
|
|
21
|
+
"""
|
|
22
|
+
|
|
23
|
+
import atexit
|
|
24
|
+
import os
|
|
25
|
+
import time
|
|
26
|
+
|
|
27
|
+
from . import _core
|
|
28
|
+
from . import _proto as P
|
|
29
|
+
from ._core import ( # noqa: F401 - public re-exports
|
|
30
|
+
CRITICAL, DETAIL, ERROR, IMPORTANT, INFO, NORMAL, WARNING, Config, __version__, error,
|
|
31
|
+
error_message, flow_begin, flow_end, flow_step, frame, instant, message, new_flow_id,
|
|
32
|
+
now_ticks, plot, set_min_level, set_thread_name, traced, warn, warn_message, zone,
|
|
33
|
+
)
|
|
34
|
+
from . import _sysinfo
|
|
35
|
+
from ._sysinfo import set_system_info # noqa: F401
|
|
36
|
+
from ._wsgi import wsgi_middleware # noqa: F401
|
|
37
|
+
from ._logging import LoggingHandler # noqa: F401
|
|
38
|
+
|
|
39
|
+
__all__ = [
|
|
40
|
+
"init", "shutdown", "is_active", "port", "stats", "zone", "traced", "instant", "warn",
|
|
41
|
+
"error", "plot", "message", "warn_message", "error_message", "frame", "flow_begin",
|
|
42
|
+
"flow_step", "flow_end", "new_flow_id", "save", "export_chrome_json", "wsgi_middleware",
|
|
43
|
+
"set_thread_name", "set_min_level", "set_system_info", "now_ticks", "LoggingHandler",
|
|
44
|
+
"Config", "DETAIL", "NORMAL", "IMPORTANT", "CRITICAL", "INFO", "WARNING", "ERROR", "__version__",
|
|
45
|
+
]
|
|
46
|
+
|
|
47
|
+
# init() / shutdown() run under this lock. A _TracerLock: a signal handler that
|
|
48
|
+
# calls shutdown() (or init()) while this thread is already inside one of them,
|
|
49
|
+
# e.g. a second Ctrl+C while the first shutdown joins the server thread, finds
|
|
50
|
+
# the lock held by its own thread and returns instead of deadlocking, and an
|
|
51
|
+
# asynchronous exception never leaves it held.
|
|
52
|
+
_init_lock = _core._TracerLock()
|
|
53
|
+
_atexit_registered = False
|
|
54
|
+
|
|
55
|
+
|
|
56
|
+
def init(process_name=None, port=P.DEFAULT_PORT, **options):
|
|
57
|
+
"""Starts recording (and, unless disabled, the streaming server).
|
|
58
|
+
|
|
59
|
+
Options (keyword arguments, see :class:`svkt.Config`):
|
|
60
|
+
|
|
61
|
+
* ``bind_address`` ("127.0.0.1": only consumers on this machine can connect; the
|
|
62
|
+
stream is neither authenticated nor encrypted, so "0.0.0.0" or an interface
|
|
63
|
+
address is an explicit choice; for a remote viewer prefer an SSH tunnel; "" is
|
|
64
|
+
refused: no server, a line on stderr),
|
|
65
|
+
``port`` (47474; 0 = ephemeral), ``port_range`` (16)
|
|
66
|
+
* ``enable_server`` (True), ``enable_discovery`` (True: the local registry file),
|
|
67
|
+
``discovery_multicast`` (True: also announces by multicast, only on the
|
|
68
|
+
interface(s) ``bind_address`` listens on, PROTOCOL 7.1; False: registry file only)
|
|
69
|
+
* ``tiers``: list of ``(capacity_in_records, min_level)``; shared by all threads.
|
|
70
|
+
Default ``[(100000, DETAIL), (50000, NORMAL), (25000, IMPORTANT)]``.
|
|
71
|
+
* ``min_level`` (DETAIL): runtime recording filter.
|
|
72
|
+
* ``stream_interval_ms`` (10), ``max_live_records`` (200000, per consumer)
|
|
73
|
+
* ``max_consumers`` (4, clamped to 1..64): consumers served at once; one more
|
|
74
|
+
gets ``Error{Busy}`` unless a consumer has been silent for 5 s (it is replaced)
|
|
75
|
+
* ``allow_remote_save`` (True, loopback peers only),
|
|
76
|
+
``allow_remote_save_from_network`` (False), ``save_directory`` (Windows %TEMP%/svkt;
|
|
77
|
+
POSIX <TMPDIR or /tmp>/svkt-<euid>, private),
|
|
78
|
+
``save_max_files`` (50), ``save_max_bytes`` (2 GiB)
|
|
79
|
+
|
|
80
|
+
Returns True if started, False if already active (also when called from a
|
|
81
|
+
signal handler while this thread is inside init() or shutdown()). Raises
|
|
82
|
+
ValueError / TypeError on invalid options.
|
|
83
|
+
"""
|
|
84
|
+
try:
|
|
85
|
+
return _init_lock.run(_init_locked, process_name, port, options)
|
|
86
|
+
except _core._Reentrant:
|
|
87
|
+
return False
|
|
88
|
+
|
|
89
|
+
|
|
90
|
+
def _init_locked(process_name, port, options):
|
|
91
|
+
global _atexit_registered
|
|
92
|
+
if _core._tracer is not None:
|
|
93
|
+
return False
|
|
94
|
+
cfg = Config(process_name=process_name, port=port, **options)
|
|
95
|
+
tr = _core.Tracer(cfg)
|
|
96
|
+
listener, bound_port = None, 0
|
|
97
|
+
if cfg.enable_server:
|
|
98
|
+
from ._server import bind_listener
|
|
99
|
+
listener, bound_port = bind_listener(cfg)
|
|
100
|
+
announcer = None
|
|
101
|
+
if cfg.enable_server and cfg.enable_discovery and listener is not None:
|
|
102
|
+
from ._discovery import Announcer
|
|
103
|
+
try:
|
|
104
|
+
listen_address = listener.getsockname()[0]
|
|
105
|
+
except OSError:
|
|
106
|
+
listen_address = None
|
|
107
|
+
# Announced only where the listener listens (PROTOCOL 7.1).
|
|
108
|
+
announcer = Announcer(tr, listen_address)
|
|
109
|
+
from ._server import Server
|
|
110
|
+
srv = Server(tr, listener, bound_port, announcer)
|
|
111
|
+
tr.server = srv
|
|
112
|
+
_core._set_tracer(tr)
|
|
113
|
+
srv.start()
|
|
114
|
+
if cfg.install_atexit and not _atexit_registered:
|
|
115
|
+
atexit.register(_atexit_shutdown)
|
|
116
|
+
_atexit_registered = True
|
|
117
|
+
return True
|
|
118
|
+
|
|
119
|
+
|
|
120
|
+
def _atexit_shutdown():
|
|
121
|
+
try:
|
|
122
|
+
shutdown()
|
|
123
|
+
except Exception: # noqa: BLE001
|
|
124
|
+
pass
|
|
125
|
+
|
|
126
|
+
|
|
127
|
+
def shutdown(timeout=5.0):
|
|
128
|
+
"""Stops recording and the server thread (a connected consumer receives the
|
|
129
|
+
remaining live data and Goodbye); removes the registry file.
|
|
130
|
+
|
|
131
|
+
Called from a signal handler while this thread is already inside
|
|
132
|
+
shutdown() (or init()), it returns at once: the outer call finishes."""
|
|
133
|
+
try:
|
|
134
|
+
_init_lock.run(_shutdown_locked, timeout)
|
|
135
|
+
except _core._Reentrant:
|
|
136
|
+
pass
|
|
137
|
+
|
|
138
|
+
|
|
139
|
+
def _shutdown_locked(timeout):
|
|
140
|
+
tr = _core._tracer
|
|
141
|
+
if tr is None:
|
|
142
|
+
return
|
|
143
|
+
_core._set_tracer(None)
|
|
144
|
+
tr.active = False
|
|
145
|
+
if tr.server is not None:
|
|
146
|
+
tr.server.stop(timeout)
|
|
147
|
+
|
|
148
|
+
|
|
149
|
+
def is_active():
|
|
150
|
+
return _core._tracer is not None
|
|
151
|
+
|
|
152
|
+
|
|
153
|
+
def port():
|
|
154
|
+
"""The TCP port the server listens on (0 if not listening / not active)."""
|
|
155
|
+
tr = _core._tracer
|
|
156
|
+
if tr is None or tr.server is None:
|
|
157
|
+
return 0
|
|
158
|
+
return tr.server.port
|
|
159
|
+
|
|
160
|
+
|
|
161
|
+
def stats():
|
|
162
|
+
"""Counters (events written/demoted/discarded/streamed/dropped, tier fill, ...)."""
|
|
163
|
+
tr = _core._tracer
|
|
164
|
+
if tr is None:
|
|
165
|
+
return {}
|
|
166
|
+
return tr.stats()
|
|
167
|
+
|
|
168
|
+
|
|
169
|
+
def _require():
|
|
170
|
+
tr = _core._tracer
|
|
171
|
+
if tr is None:
|
|
172
|
+
raise RuntimeError("svkt is not initialised (call svkt.init() first)")
|
|
173
|
+
return tr
|
|
174
|
+
|
|
175
|
+
|
|
176
|
+
def save(path=None):
|
|
177
|
+
"""Saves all retained data (all tiers, open zones, clock log) as a native
|
|
178
|
+
``.svkt`` file. Without ``path`` a name ``<process>_<pid>_<UTC time>.svkt``
|
|
179
|
+
in the save directory is used. Runs on the calling thread. Returns the path."""
|
|
180
|
+
from ._save import default_save_directory, prepare_save_directory, save_file_name, save_to_path
|
|
181
|
+
tr = _require()
|
|
182
|
+
if path is not None:
|
|
183
|
+
return save_to_path(tr, path, P.SAVE_NATIVE)
|
|
184
|
+
# Default name: created exclusively, never overwriting an earlier save
|
|
185
|
+
# (a numeric tag is added when two saves fall into the same second).
|
|
186
|
+
d = tr.cfg.save_directory or default_save_directory()
|
|
187
|
+
prepare_save_directory(d, not tr.cfg.save_directory)
|
|
188
|
+
when = time.time()
|
|
189
|
+
for i in range(1000):
|
|
190
|
+
name = save_file_name(tr.process_name, tr.pid, str(i) if i else "", P.SAVE_NATIVE, when)
|
|
191
|
+
try:
|
|
192
|
+
return save_to_path(tr, os.path.join(d, name), P.SAVE_NATIVE, exclusive=True)
|
|
193
|
+
except FileExistsError:
|
|
194
|
+
continue
|
|
195
|
+
raise FileExistsError("no free save file name in %s" % d)
|
|
196
|
+
|
|
197
|
+
|
|
198
|
+
def export_chrome_json(path):
|
|
199
|
+
"""Exports all retained data as Chrome Trace Event JSON (Perfetto UI,
|
|
200
|
+
chrome://tracing). Returns the path."""
|
|
201
|
+
from ._save import save_to_path
|
|
202
|
+
tr = _require()
|
|
203
|
+
return save_to_path(tr, path, P.SAVE_CHROME_JSON)
|
|
204
|
+
|
|
205
|
+
|
|
206
|
+
def _after_fork_in_child():
|
|
207
|
+
# The child has no server thread and possibly a lock held by a thread that
|
|
208
|
+
# does not exist there: tracing is off in the child until init() is called.
|
|
209
|
+
# The child's copies of the parent's sockets are closed (no traffic), so a
|
|
210
|
+
# long-lived child does not keep the parent's port listening.
|
|
211
|
+
# set_system_info() entries stay (process state); only their lock is renewed.
|
|
212
|
+
global _init_lock
|
|
213
|
+
_init_lock = _core._TracerLock()
|
|
214
|
+
_sysinfo._after_fork_in_child()
|
|
215
|
+
tr = _core._tracer
|
|
216
|
+
_core._set_tracer(None)
|
|
217
|
+
srv = getattr(tr, "server", None)
|
|
218
|
+
if srv is not None:
|
|
219
|
+
try:
|
|
220
|
+
srv.close_fds_after_fork()
|
|
221
|
+
except Exception: # noqa: BLE001 - never break the child's fork
|
|
222
|
+
pass
|
|
223
|
+
|
|
224
|
+
|
|
225
|
+
if hasattr(os, "register_at_fork"):
|
|
226
|
+
os.register_at_fork(after_in_child=_after_fork_in_child)
|
svkt/_clock.py
ADDED
|
@@ -0,0 +1,237 @@
|
|
|
1
|
+
"""Timestamps, clock samples, the retained clock log and clock_domain_id.
|
|
2
|
+
|
|
3
|
+
Ticks are ``time.perf_counter_ns()`` (PROTOCOL 2.1: QPC on Windows with the
|
|
4
|
+
exact integer formula, CLOCK_MONOTONIC on Linux) and ``ns_per_tick == 1.0``.
|
|
5
|
+
``monotonic_ns = ticks + MONO_OFFSET``; ``MONO_OFFSET`` is 0 except on Windows
|
|
6
|
+
with Python < 3.10, where ``perf_counter_ns()`` counts from interpreter start
|
|
7
|
+
(CPython subtracts the QPC value it read first) instead of being system-wide:
|
|
8
|
+
there the offset back to the system-wide QPC clock is measured once at import
|
|
9
|
+
(:func:`_windows_qpc_offset`), so ClockSync, Pong, ``clock_domain_id`` and the
|
|
10
|
+
Chrome export report the system-wide clock while the recording path keeps
|
|
11
|
+
calling ``perf_counter_ns`` directly.
|
|
12
|
+
"""
|
|
13
|
+
|
|
14
|
+
import collections
|
|
15
|
+
import sys
|
|
16
|
+
import time
|
|
17
|
+
|
|
18
|
+
from ._lock import _TracerLock
|
|
19
|
+
|
|
20
|
+
now = time.perf_counter_ns
|
|
21
|
+
|
|
22
|
+
|
|
23
|
+
def _windows_qpc_offset(trials=200):
|
|
24
|
+
"""System-wide QPC ns minus ``perf_counter_ns()`` (Windows, Python < 3.10).
|
|
25
|
+
|
|
26
|
+
QPC ns use the PROTOCOL 2.1 integer formula. Each trial reads QPC, then
|
|
27
|
+
``perf_counter_ns``, then QPC again; the offset lies inside every trial's
|
|
28
|
+
interval [lo, hi], so it lies in the intersection of all of them, which is
|
|
29
|
+
at most as wide as the narrowest bracket. The midpoint is returned; when
|
|
30
|
+
the QPC period is a whole number of ns (1e9 % f == 0, e.g. 10 MHz) the
|
|
31
|
+
offset is a multiple of the period and the midpoint is rounded to one
|
|
32
|
+
(still inside the intersection, whose ends are multiples too).
|
|
33
|
+
|
|
34
|
+
Not exact, and no exact method exists: CPython 3.8 / 3.9 compute
|
|
35
|
+
``perf_counter_ns = muldiv(QPC - t0, 1e9, f)`` with t0, the QPC value read
|
|
36
|
+
at interpreter start, kept in a private C static, so the offset (t0 x the
|
|
37
|
+
period at 10 MHz) can only be bracketed, and a bracket of two ctypes QPC
|
|
38
|
+
calls is wider than one QPC period. Bound: the error is at most the
|
|
39
|
+
distance to the farther end of the intersection, about half its width
|
|
40
|
+
rounded up to one QPC period. Measured on a 10 MHz QPC: intersections 200
|
|
41
|
+
to 300 ns wide on 3.8, so the error is at most 200 ns (in practice 0 or
|
|
42
|
+
one period, varying from process to process). Python 3.8 / 3.9 events can
|
|
43
|
+
thus be up to that far off against other processes on the host.
|
|
44
|
+
Returns None if QPC cannot be read."""
|
|
45
|
+
import ctypes
|
|
46
|
+
k32 = ctypes.WinDLL("kernel32")
|
|
47
|
+
freq = ctypes.c_int64()
|
|
48
|
+
if not k32.QueryPerformanceFrequency(ctypes.byref(freq)) or freq.value <= 0:
|
|
49
|
+
return None
|
|
50
|
+
f = freq.value
|
|
51
|
+
c = ctypes.c_int64()
|
|
52
|
+
ref = ctypes.byref(c)
|
|
53
|
+
qpc = k32.QueryPerformanceCounter
|
|
54
|
+
pc = time.perf_counter_ns
|
|
55
|
+
lo = hi = None
|
|
56
|
+
for _ in range(trials):
|
|
57
|
+
qpc(ref)
|
|
58
|
+
c1 = c.value
|
|
59
|
+
p = pc()
|
|
60
|
+
qpc(ref)
|
|
61
|
+
c2 = c.value
|
|
62
|
+
a = (c1 // f) * 1_000_000_000 + (c1 % f) * 1_000_000_000 // f - p
|
|
63
|
+
b = (c2 // f) * 1_000_000_000 + (c2 % f) * 1_000_000_000 // f - p
|
|
64
|
+
lo = a if lo is None else max(lo, a)
|
|
65
|
+
hi = b if hi is None else min(hi, b)
|
|
66
|
+
if lo > hi: # only possible through +-1 ns conversion rounding
|
|
67
|
+
lo, hi = hi, lo
|
|
68
|
+
off = (lo + hi) // 2
|
|
69
|
+
if 1_000_000_000 % f == 0:
|
|
70
|
+
period = 1_000_000_000 // f
|
|
71
|
+
off = (off + period // 2) // period * period
|
|
72
|
+
return off
|
|
73
|
+
|
|
74
|
+
|
|
75
|
+
# ticks + MONO_OFFSET == system-wide monotonic ns (PROTOCOL 2.1). MONO_OK is
|
|
76
|
+
# False if the offset is needed but could not be measured (then the clock
|
|
77
|
+
# domain is reported as unknown).
|
|
78
|
+
MONO_OFFSET = 0
|
|
79
|
+
MONO_OK = True
|
|
80
|
+
if sys.platform == "win32" and sys.version_info < (3, 10):
|
|
81
|
+
try:
|
|
82
|
+
_off = _windows_qpc_offset()
|
|
83
|
+
except (OSError, AttributeError, ImportError): # pragma: no cover
|
|
84
|
+
_off = None
|
|
85
|
+
if _off is None: # pragma: no cover
|
|
86
|
+
MONO_OK = False
|
|
87
|
+
else:
|
|
88
|
+
MONO_OFFSET = _off
|
|
89
|
+
|
|
90
|
+
|
|
91
|
+
def sample_interval_ns():
|
|
92
|
+
"""Spacing of the retained and live clock samples (PROTOCOL 2.2). 1 s while
|
|
93
|
+
ticks are the monotonic clock (identity: consumers map events exactly
|
|
94
|
+
without waiting for a sample). 100 ms when they are not (``MONO_OFFSET !=
|
|
95
|
+
0``: Windows, Python 3.8 / 3.9), as PROTOCOL 2.2 asks of such producers:
|
|
96
|
+
a live consumer holds events newer than the newest sample back until the
|
|
97
|
+
next one, so this bounds that wait to about 100 ms (the C++ reader's own
|
|
98
|
+
bound is 250 ms)."""
|
|
99
|
+
return 1_000_000_000 if MONO_OFFSET == 0 else 100_000_000
|
|
100
|
+
|
|
101
|
+
|
|
102
|
+
def sample():
|
|
103
|
+
"""One tightly bracketed (ticks, monotonic_ns, realtime_ns) sample.
|
|
104
|
+
|
|
105
|
+
Takes the minimum-latency bracket of several ``tick, wall, tick`` reads and
|
|
106
|
+
uses the midpoint tick (PROTOCOL 2.2)."""
|
|
107
|
+
best = None
|
|
108
|
+
pc = time.perf_counter_ns
|
|
109
|
+
wall = time.time_ns
|
|
110
|
+
for _ in range(5):
|
|
111
|
+
a = pc()
|
|
112
|
+
r = wall()
|
|
113
|
+
b = pc()
|
|
114
|
+
if best is None or b - a < best[0]:
|
|
115
|
+
best = (b - a, (a + b) // 2, r)
|
|
116
|
+
mid = best[1]
|
|
117
|
+
return (mid, mid + MONO_OFFSET, best[2])
|
|
118
|
+
|
|
119
|
+
|
|
120
|
+
class ClockLog:
|
|
121
|
+
"""Retained clock samples, independent of any consumer (PROTOCOL 2.2).
|
|
122
|
+
|
|
123
|
+
Keeps the init sample, one sample per :func:`sample_interval_ns` (1 s, or
|
|
124
|
+
100 ms on Windows with Python 3.8 / 3.9) for the last 60 s and one per
|
|
125
|
+
minute in a 1024-entry ring. (Python ticks are the monotonic clock, or
|
|
126
|
+
differ from it by the constant MONO_OFFSET, so mapping is exact at any
|
|
127
|
+
spacing; the 100 ms spacing only shortens how long a live consumer holds
|
|
128
|
+
events back, see :func:`sample_interval_ns`.) Each new sample is also
|
|
129
|
+
streamed to the consumer. Maintained by the background thread via
|
|
130
|
+
:meth:`tick`; thread safe.
|
|
131
|
+
|
|
132
|
+
The lock is a ``_TracerLock`` (sections run through ``run``): saves take
|
|
133
|
+
it on the application's thread, so a signal handler that saves while the
|
|
134
|
+
same thread is inside a section gets ``_Reentrant`` instead of a deadlock,
|
|
135
|
+
and an asynchronous exception (Ctrl+C) never leaves it held, which would
|
|
136
|
+
stop the server thread at its next tick."""
|
|
137
|
+
|
|
138
|
+
def __init__(self, interval_ns=None):
|
|
139
|
+
self._lock = _TracerLock()
|
|
140
|
+
self.interval_ns = sample_interval_ns() if interval_ns is None else int(interval_ns)
|
|
141
|
+
self._init = sample()
|
|
142
|
+
self._seconds = collections.deque(maxlen=max(1, 60_000_000_000 // self.interval_ns))
|
|
143
|
+
self._minutes = collections.deque(maxlen=1024)
|
|
144
|
+
self._last_sec_tick = self._init[0]
|
|
145
|
+
self._last_min_tick = self._init[0]
|
|
146
|
+
self._latest = self._init
|
|
147
|
+
|
|
148
|
+
def tick(self, force=False):
|
|
149
|
+
"""Takes a new sample if >= interval_ns passed since the last periodic
|
|
150
|
+
one (or force). Returns the new sample or None. A forced sample (for a
|
|
151
|
+
handshake or a save) is retained but does not move the periodic
|
|
152
|
+
schedule: the next periodic sample, the one streamed to the consumers
|
|
153
|
+
already connected, is still due interval_ns after the previous one, however
|
|
154
|
+
often forced samples are taken (PROTOCOL 2.2)."""
|
|
155
|
+
t = now()
|
|
156
|
+
if not force and t - self._last_sec_tick < self.interval_ns:
|
|
157
|
+
return None
|
|
158
|
+
s = sample()
|
|
159
|
+
self._lock.run(self._add, s, force)
|
|
160
|
+
return s
|
|
161
|
+
|
|
162
|
+
def _add(self, s, force):
|
|
163
|
+
self._seconds.append(s)
|
|
164
|
+
if not force:
|
|
165
|
+
self._last_sec_tick = s[0]
|
|
166
|
+
if s[0] - self._last_min_tick >= 60_000_000_000:
|
|
167
|
+
self._minutes.append(s)
|
|
168
|
+
self._last_min_tick = s[0]
|
|
169
|
+
self._latest = s
|
|
170
|
+
|
|
171
|
+
def latest(self):
|
|
172
|
+
return self._latest # one attribute load: atomic
|
|
173
|
+
|
|
174
|
+
def _items(self):
|
|
175
|
+
items = [self._init]
|
|
176
|
+
items.extend(self._minutes)
|
|
177
|
+
items.extend(self._seconds)
|
|
178
|
+
return items
|
|
179
|
+
|
|
180
|
+
def samples(self):
|
|
181
|
+
"""All retained samples, sorted by ticks, without duplicates."""
|
|
182
|
+
items = self._lock.run(self._items)
|
|
183
|
+
seen = set()
|
|
184
|
+
out = []
|
|
185
|
+
for s in sorted(items):
|
|
186
|
+
if s[0] in seen:
|
|
187
|
+
continue
|
|
188
|
+
seen.add(s[0])
|
|
189
|
+
out.append(s)
|
|
190
|
+
return out
|
|
191
|
+
|
|
192
|
+
def to_realtime_ns(self, ticks):
|
|
193
|
+
"""Maps ticks to wall clock ns using the nearest retained sample
|
|
194
|
+
(ns_per_tick == 1, so this is a pure offset)."""
|
|
195
|
+
best = None
|
|
196
|
+
for s in self.samples():
|
|
197
|
+
d = abs(s[0] - ticks)
|
|
198
|
+
if best is None or d < best[0]:
|
|
199
|
+
best = (d, s)
|
|
200
|
+
s = best[1]
|
|
201
|
+
return s[2] + (ticks - s[0])
|
|
202
|
+
|
|
203
|
+
|
|
204
|
+
def _windows_machine_guid():
|
|
205
|
+
try:
|
|
206
|
+
import winreg
|
|
207
|
+
except ImportError: # pragma: no cover - not Windows
|
|
208
|
+
return ""
|
|
209
|
+
for access in (winreg.KEY_READ | getattr(winreg, "KEY_WOW64_64KEY", 0), winreg.KEY_READ):
|
|
210
|
+
try:
|
|
211
|
+
with winreg.OpenKey(winreg.HKEY_LOCAL_MACHINE,
|
|
212
|
+
r"SOFTWARE\Microsoft\Cryptography", 0, access) as k:
|
|
213
|
+
value, _ = winreg.QueryValueEx(k, "MachineGuid")
|
|
214
|
+
return str(value)
|
|
215
|
+
except OSError:
|
|
216
|
+
continue
|
|
217
|
+
return ""
|
|
218
|
+
|
|
219
|
+
|
|
220
|
+
def clock_domain_id():
|
|
221
|
+
"""PROTOCOL 2.3: Linux boot_id; Windows ``MachineGuid + "-" + boot time``
|
|
222
|
+
where boot time = (realtime_ns - monotonic_ns) rounded to seconds (decimal).
|
|
223
|
+
Empty if unknown."""
|
|
224
|
+
try:
|
|
225
|
+
if sys.platform.startswith("linux"):
|
|
226
|
+
with open("/proc/sys/kernel/random/boot_id", "r", encoding="ascii") as f:
|
|
227
|
+
return f.read().strip()
|
|
228
|
+
if sys.platform == "win32":
|
|
229
|
+
guid = _windows_machine_guid()
|
|
230
|
+
if not guid or not MONO_OK:
|
|
231
|
+
return ""
|
|
232
|
+
_, mono, real = sample()
|
|
233
|
+
boot_s = (real - mono + 500_000_000) // 1_000_000_000
|
|
234
|
+
return "%s-%d" % (guid, boot_s)
|
|
235
|
+
except OSError:
|
|
236
|
+
pass
|
|
237
|
+
return ""
|