pulumi-oci 1.37.0a1715927489__py3-none-any.whl → 1.37.0a1716526633__py3-none-any.whl

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (307) hide show
  1. pulumi_oci/__init__.py +40 -0
  2. pulumi_oci/adm/_inputs.py +6 -6
  3. pulumi_oci/adm/outputs.py +6 -6
  4. pulumi_oci/aianomalydetection/_inputs.py +10 -8
  5. pulumi_oci/aianomalydetection/outputs.py +22 -8
  6. pulumi_oci/aidocument/_inputs.py +22 -18
  7. pulumi_oci/aidocument/outputs.py +36 -18
  8. pulumi_oci/ailanguage/_inputs.py +4 -20
  9. pulumi_oci/ailanguage/model.py +4 -4
  10. pulumi_oci/ailanguage/outputs.py +4 -20
  11. pulumi_oci/aivision/_inputs.py +0 -16
  12. pulumi_oci/aivision/outputs.py +0 -16
  13. pulumi_oci/analytics/_inputs.py +2 -2
  14. pulumi_oci/analytics/outputs.py +2 -2
  15. pulumi_oci/apigateway/_inputs.py +206 -414
  16. pulumi_oci/apigateway/outputs.py +206 -414
  17. pulumi_oci/apmconfig/_inputs.py +4 -4
  18. pulumi_oci/apmconfig/config.py +7 -7
  19. pulumi_oci/apmconfig/outputs.py +4 -4
  20. pulumi_oci/apmsynthetics/_inputs.py +18 -26
  21. pulumi_oci/apmsynthetics/config.py +7 -7
  22. pulumi_oci/apmsynthetics/outputs.py +18 -26
  23. pulumi_oci/autoscaling/_inputs.py +14 -16
  24. pulumi_oci/autoscaling/auto_scaling_configuration.py +20 -7
  25. pulumi_oci/autoscaling/outputs.py +14 -16
  26. pulumi_oci/bigdataservice/_inputs.py +32 -44
  27. pulumi_oci/bigdataservice/bds_instance.py +4 -4
  28. pulumi_oci/bigdataservice/outputs.py +32 -44
  29. pulumi_oci/certificatesmanagement/_inputs.py +16 -16
  30. pulumi_oci/certificatesmanagement/certificate.py +16 -16
  31. pulumi_oci/certificatesmanagement/certificate_authority.py +8 -8
  32. pulumi_oci/certificatesmanagement/outputs.py +16 -16
  33. pulumi_oci/cloudbridge/_inputs.py +18 -18
  34. pulumi_oci/cloudbridge/outputs.py +18 -18
  35. pulumi_oci/cloudguard/__init__.py +9 -0
  36. pulumi_oci/cloudguard/_inputs.py +1066 -488
  37. pulumi_oci/cloudguard/adhoc_query.py +596 -0
  38. pulumi_oci/cloudguard/cloud_guard_configuration.py +25 -57
  39. pulumi_oci/cloudguard/cloud_guard_data_source.py +54 -38
  40. pulumi_oci/cloudguard/data_mask_rule.py +62 -62
  41. pulumi_oci/cloudguard/detector_recipe.py +95 -53
  42. pulumi_oci/cloudguard/get_adhoc_queries.py +253 -0
  43. pulumi_oci/cloudguard/get_adhoc_query.py +249 -0
  44. pulumi_oci/cloudguard/get_cloud_guard_configuration.py +9 -7
  45. pulumi_oci/cloudguard/get_data_mask_rule.py +14 -14
  46. pulumi_oci/cloudguard/get_data_mask_rules.py +17 -17
  47. pulumi_oci/cloudguard/get_data_source.py +10 -10
  48. pulumi_oci/cloudguard/get_data_source_events.py +11 -7
  49. pulumi_oci/cloudguard/get_data_sources.py +24 -20
  50. pulumi_oci/cloudguard/get_detector_recipe.py +28 -15
  51. pulumi_oci/cloudguard/get_detector_recipes.py +13 -13
  52. pulumi_oci/cloudguard/get_guard_target.py +14 -14
  53. pulumi_oci/cloudguard/get_guard_targets.py +19 -17
  54. pulumi_oci/cloudguard/get_managed_list.py +14 -14
  55. pulumi_oci/cloudguard/get_managed_lists.py +16 -16
  56. pulumi_oci/cloudguard/get_problem_entities.py +5 -3
  57. pulumi_oci/cloudguard/get_responder_recipe.py +13 -13
  58. pulumi_oci/cloudguard/get_responder_recipes.py +15 -13
  59. pulumi_oci/cloudguard/get_saved_queries.py +190 -0
  60. pulumi_oci/cloudguard/get_saved_query.py +235 -0
  61. pulumi_oci/cloudguard/get_security_policies.py +14 -12
  62. pulumi_oci/cloudguard/get_security_policy.py +12 -8
  63. pulumi_oci/cloudguard/get_security_recipe.py +9 -9
  64. pulumi_oci/cloudguard/get_security_recipes.py +14 -12
  65. pulumi_oci/cloudguard/get_security_zone.py +8 -8
  66. pulumi_oci/cloudguard/get_security_zones.py +17 -15
  67. pulumi_oci/cloudguard/get_wlp_agent.py +258 -0
  68. pulumi_oci/cloudguard/get_wlp_agents.py +136 -0
  69. pulumi_oci/cloudguard/managed_list.py +57 -57
  70. pulumi_oci/cloudguard/outputs.py +3493 -1808
  71. pulumi_oci/cloudguard/responder_recipe.py +41 -39
  72. pulumi_oci/cloudguard/saved_query.py +595 -0
  73. pulumi_oci/cloudguard/security_recipe.py +43 -27
  74. pulumi_oci/cloudguard/security_zone.py +22 -20
  75. pulumi_oci/cloudguard/target.py +54 -54
  76. pulumi_oci/cloudguard/wlp_agent.py +654 -0
  77. pulumi_oci/cloudmigrations/_inputs.py +222 -496
  78. pulumi_oci/cloudmigrations/outputs.py +222 -496
  79. pulumi_oci/cloudmigrations/target_asset.py +15 -15
  80. pulumi_oci/clusterplacementgroups/_inputs.py +2 -2
  81. pulumi_oci/clusterplacementgroups/outputs.py +2 -2
  82. pulumi_oci/computecloud/at_customer_ccc_upgrade_schedule.py +7 -7
  83. pulumi_oci/containerengine/_inputs.py +22 -22
  84. pulumi_oci/containerengine/container_instance.py +21 -21
  85. pulumi_oci/containerengine/outputs.py +22 -22
  86. pulumi_oci/containerengine/virtual_node_pool.py +7 -35
  87. pulumi_oci/core/_inputs.py +404 -670
  88. pulumi_oci/core/boot_volume.py +7 -7
  89. pulumi_oci/core/cluster_network.py +22 -22
  90. pulumi_oci/core/cross_connect_group.py +4 -20
  91. pulumi_oci/core/drg_route_table_route_rule.py +7 -0
  92. pulumi_oci/core/get_image.py +4 -0
  93. pulumi_oci/core/get_instance.py +4 -0
  94. pulumi_oci/core/get_public_ip.py +4 -0
  95. pulumi_oci/core/get_public_ips.py +8 -0
  96. pulumi_oci/core/get_vtap.py +2 -0
  97. pulumi_oci/core/get_vtaps.py +2 -0
  98. pulumi_oci/core/image.py +56 -0
  99. pulumi_oci/core/instance.py +48 -48
  100. pulumi_oci/core/instance_configuration.py +70 -28
  101. pulumi_oci/core/instance_pool.py +7 -7
  102. pulumi_oci/core/ipsec_connection_tunnel_management.py +8 -8
  103. pulumi_oci/core/network_security_group_security_rule.py +28 -105
  104. pulumi_oci/core/outputs.py +748 -668
  105. pulumi_oci/core/public_ip.py +8 -0
  106. pulumi_oci/core/vnic_attachment.py +8 -24
  107. pulumi_oci/core/volume.py +7 -7
  108. pulumi_oci/core/volume_group.py +7 -7
  109. pulumi_oci/core/vtap.py +14 -0
  110. pulumi_oci/database/_inputs.py +188 -220
  111. pulumi_oci/database/autonomous_database.py +21 -7
  112. pulumi_oci/database/autonomous_database_wallet.py +28 -0
  113. pulumi_oci/database/backup_destination.py +11 -11
  114. pulumi_oci/database/cloud_database_management.py +14 -0
  115. pulumi_oci/database/database.py +28 -44
  116. pulumi_oci/database/database_upgrade.py +4 -4
  117. pulumi_oci/database/db_home.py +0 -13
  118. pulumi_oci/database/get_autonomous_database_wallet.py +8 -0
  119. pulumi_oci/database/outputs.py +188 -220
  120. pulumi_oci/database/vm_cluster_network.py +4 -4
  121. pulumi_oci/databasemanagement/_inputs.py +8 -8
  122. pulumi_oci/databasemanagement/outputs.py +8 -8
  123. pulumi_oci/databasemigration/_inputs.py +34 -34
  124. pulumi_oci/databasemigration/connection.py +7 -7
  125. pulumi_oci/databasemigration/migration.py +7 -7
  126. pulumi_oci/databasemigration/outputs.py +34 -34
  127. pulumi_oci/databasetools/_inputs.py +12 -36
  128. pulumi_oci/databasetools/database_tools_connection.py +4 -4
  129. pulumi_oci/databasetools/database_tools_private_endpoint.py +4 -4
  130. pulumi_oci/databasetools/outputs.py +12 -36
  131. pulumi_oci/dataintegration/_inputs.py +318 -330
  132. pulumi_oci/dataintegration/outputs.py +318 -330
  133. pulumi_oci/dataintegration/workspace_application.py +7 -7
  134. pulumi_oci/dataintegration/workspace_application_patch.py +7 -7
  135. pulumi_oci/dataintegration/workspace_application_schedule.py +11 -11
  136. pulumi_oci/dataintegration/workspace_application_task_schedule.py +29 -29
  137. pulumi_oci/dataintegration/workspace_folder.py +7 -7
  138. pulumi_oci/dataintegration/workspace_project.py +7 -7
  139. pulumi_oci/dataintegration/workspace_task.py +47 -47
  140. pulumi_oci/datalabellingservice/_inputs.py +10 -10
  141. pulumi_oci/datalabellingservice/outputs.py +10 -10
  142. pulumi_oci/datasafe/__init__.py +2 -0
  143. pulumi_oci/datasafe/_inputs.py +72 -80
  144. pulumi_oci/datasafe/library_masing_format.py +7 -7
  145. pulumi_oci/datasafe/masking_policies_masking_column.py +7 -7
  146. pulumi_oci/datasafe/masking_policy.py +7 -7
  147. pulumi_oci/datasafe/outputs.py +72 -80
  148. pulumi_oci/datasafe/report_definition.py +8 -24
  149. pulumi_oci/datasafe/set_security_assessment_baseline_management.py +304 -0
  150. pulumi_oci/datasafe/set_user_assessment_baseline_management.py +304 -0
  151. pulumi_oci/datasafe/target_database.py +21 -21
  152. pulumi_oci/datascience/_inputs.py +337 -65
  153. pulumi_oci/datascience/get_job_run.py +11 -1
  154. pulumi_oci/datascience/get_model_deployment.py +11 -1
  155. pulumi_oci/datascience/get_pipeline.py +3 -0
  156. pulumi_oci/datascience/get_pipeline_run.py +14 -1
  157. pulumi_oci/datascience/job_run.py +52 -3
  158. pulumi_oci/datascience/model_deployment.py +51 -2
  159. pulumi_oci/datascience/outputs.py +767 -104
  160. pulumi_oci/datascience/pipeline.py +34 -14
  161. pulumi_oci/datascience/pipeline_run.py +65 -0
  162. pulumi_oci/devops/_inputs.py +80 -462
  163. pulumi_oci/devops/deploy_stage.py +4 -4
  164. pulumi_oci/devops/deployment.py +7 -7
  165. pulumi_oci/devops/outputs.py +208 -1141
  166. pulumi_oci/disasterrecovery/_inputs.py +6 -6
  167. pulumi_oci/disasterrecovery/dr_plan_execution.py +4 -4
  168. pulumi_oci/disasterrecovery/dr_protection_group.py +4 -4
  169. pulumi_oci/disasterrecovery/outputs.py +6 -6
  170. pulumi_oci/dns/_inputs.py +20 -8
  171. pulumi_oci/dns/outputs.py +42 -8
  172. pulumi_oci/dns/rrset.py +7 -7
  173. pulumi_oci/dns/steering_policy.py +42 -0
  174. pulumi_oci/events/_inputs.py +4 -12
  175. pulumi_oci/events/outputs.py +4 -12
  176. pulumi_oci/events/rule.py +7 -7
  177. pulumi_oci/functions/_inputs.py +2 -2
  178. pulumi_oci/functions/outputs.py +2 -2
  179. pulumi_oci/goldengate/_inputs.py +2 -4
  180. pulumi_oci/goldengate/outputs.py +2 -4
  181. pulumi_oci/identity/_inputs.py +4860 -5954
  182. pulumi_oci/identity/domains_api_key.py +70 -70
  183. pulumi_oci/identity/domains_app.py +119 -140
  184. pulumi_oci/identity/domains_auth_token.py +21 -21
  185. pulumi_oci/identity/domains_cloud_gate.py +49 -49
  186. pulumi_oci/identity/domains_customer_secret_key.py +21 -21
  187. pulumi_oci/identity/domains_my_api_key.py +70 -70
  188. pulumi_oci/identity/domains_my_auth_token.py +21 -21
  189. pulumi_oci/identity/domains_my_customer_secret_key.py +21 -21
  190. pulumi_oci/identity/domains_my_oauth2client_credential.py +49 -70
  191. pulumi_oci/identity/domains_my_smtp_credential.py +21 -21
  192. pulumi_oci/identity/domains_my_support_account.py +21 -21
  193. pulumi_oci/identity/domains_my_user_db_credential.py +37 -41
  194. pulumi_oci/identity/domains_oauth2client_credential.py +49 -70
  195. pulumi_oci/identity/domains_policy.py +35 -49
  196. pulumi_oci/identity/domains_rule.py +28 -21
  197. pulumi_oci/identity/domains_setting.py +35 -21
  198. pulumi_oci/identity/domains_smtp_credential.py +21 -21
  199. pulumi_oci/identity/domains_user.py +189 -175
  200. pulumi_oci/identity/domains_user_db_credential.py +37 -41
  201. pulumi_oci/identity/outputs.py +4913 -6007
  202. pulumi_oci/integration/_inputs.py +4 -0
  203. pulumi_oci/integration/outputs.py +16 -4
  204. pulumi_oci/jms/_inputs.py +0 -8
  205. pulumi_oci/jms/outputs.py +0 -8
  206. pulumi_oci/kms/_inputs.py +6 -6
  207. pulumi_oci/kms/outputs.py +6 -6
  208. pulumi_oci/loadbalancer/_inputs.py +14 -30
  209. pulumi_oci/loadbalancer/load_balancer_routing_policy.py +7 -35
  210. pulumi_oci/loadbalancer/outputs.py +14 -30
  211. pulumi_oci/loganalytics/_inputs.py +26 -34
  212. pulumi_oci/loganalytics/outputs.py +26 -34
  213. pulumi_oci/logging/_inputs.py +60 -60
  214. pulumi_oci/logging/outputs.py +60 -60
  215. pulumi_oci/managementagent/_inputs.py +2 -46
  216. pulumi_oci/managementagent/outputs.py +2 -46
  217. pulumi_oci/marketplace/_inputs.py +6 -6
  218. pulumi_oci/marketplace/outputs.py +6 -6
  219. pulumi_oci/marketplace/publication.py +11 -11
  220. pulumi_oci/mediaservices/_inputs.py +8 -32
  221. pulumi_oci/mediaservices/media_asset.py +18 -18
  222. pulumi_oci/mediaservices/media_workflow.py +22 -38
  223. pulumi_oci/mediaservices/media_workflow_configuration.py +11 -11
  224. pulumi_oci/mediaservices/media_workflow_job.py +11 -11
  225. pulumi_oci/mediaservices/outputs.py +8 -32
  226. pulumi_oci/mediaservices/stream_cdn_config.py +4 -4
  227. pulumi_oci/mediaservices/stream_distribution_channel.py +11 -11
  228. pulumi_oci/mediaservices/stream_packaging_config.py +4 -4
  229. pulumi_oci/meteringcomputation/_inputs.py +2 -2
  230. pulumi_oci/meteringcomputation/outputs.py +2 -2
  231. pulumi_oci/meteringcomputation/usage_statement_email_recipients_group.py +4 -4
  232. pulumi_oci/monitoring/_inputs.py +4 -4
  233. pulumi_oci/monitoring/alarm.py +21 -0
  234. pulumi_oci/monitoring/get_alarm.py +3 -0
  235. pulumi_oci/monitoring/outputs.py +10 -4
  236. pulumi_oci/mysql/_inputs.py +30 -22
  237. pulumi_oci/mysql/outputs.py +30 -22
  238. pulumi_oci/mysql/replica.py +12 -28
  239. pulumi_oci/networkfirewall/get_network_firewall_policy_mapped_secret.py +2 -0
  240. pulumi_oci/networkfirewall/network_firewall_policy_mapped_secret.py +14 -0
  241. pulumi_oci/networkfirewall/outputs.py +4 -0
  242. pulumi_oci/networkloadbalancer/_inputs.py +10 -26
  243. pulumi_oci/networkloadbalancer/outputs.py +10 -26
  244. pulumi_oci/nosql/_inputs.py +4 -12
  245. pulumi_oci/nosql/outputs.py +4 -12
  246. pulumi_oci/objectstorage/_inputs.py +4 -4
  247. pulumi_oci/objectstorage/outputs.py +4 -4
  248. pulumi_oci/ocvp/_inputs.py +86 -42
  249. pulumi_oci/ocvp/get_retrieve_password.py +1 -0
  250. pulumi_oci/ocvp/outputs.py +86 -42
  251. pulumi_oci/ocvp/sddc.py +49 -77
  252. pulumi_oci/ons/subscription.py +63 -0
  253. pulumi_oci/opa/_inputs.py +6 -2
  254. pulumi_oci/opa/outputs.py +18 -6
  255. pulumi_oci/opsi/_inputs.py +6 -6
  256. pulumi_oci/opsi/exadata_insight.py +28 -28
  257. pulumi_oci/opsi/outputs.py +6 -6
  258. pulumi_oci/optimizer/_inputs.py +4 -4
  259. pulumi_oci/optimizer/outputs.py +4 -4
  260. pulumi_oci/osmanagement/_inputs.py +2 -10
  261. pulumi_oci/osmanagement/outputs.py +2 -10
  262. pulumi_oci/osmanagementhub/_inputs.py +24 -8
  263. pulumi_oci/osmanagementhub/event.py +32 -0
  264. pulumi_oci/osmanagementhub/get_event.py +8 -0
  265. pulumi_oci/osmanagementhub/get_events.py +8 -0
  266. pulumi_oci/osmanagementhub/lifecycle_environment.py +14 -14
  267. pulumi_oci/osmanagementhub/outputs.py +40 -8
  268. pulumi_oci/osmanagementhub/software_source.py +7 -7
  269. pulumi_oci/ospgateway/_inputs.py +96 -96
  270. pulumi_oci/ospgateway/outputs.py +96 -96
  271. pulumi_oci/ospgateway/subscription.py +80 -80
  272. pulumi_oci/psql/_inputs.py +10 -18
  273. pulumi_oci/psql/db_system.py +14 -14
  274. pulumi_oci/psql/outputs.py +10 -18
  275. pulumi_oci/pulumi-plugin.json +1 -1
  276. pulumi_oci/queue/get_queue.py +9 -9
  277. pulumi_oci/queue/outputs.py +5 -5
  278. pulumi_oci/queue/queue.py +77 -26
  279. pulumi_oci/sch/_inputs.py +26 -26
  280. pulumi_oci/sch/connector.py +7 -7
  281. pulumi_oci/sch/outputs.py +26 -26
  282. pulumi_oci/servicecatalog/private_application.py +4 -4
  283. pulumi_oci/servicemesh/_inputs.py +8 -24
  284. pulumi_oci/servicemesh/ingress_gateway_route_table.py +7 -7
  285. pulumi_oci/servicemesh/outputs.py +8 -24
  286. pulumi_oci/stackmonitoring/_inputs.py +40 -56
  287. pulumi_oci/stackmonitoring/metric_extension.py +18 -18
  288. pulumi_oci/stackmonitoring/monitored_resource.py +7 -7
  289. pulumi_oci/stackmonitoring/outputs.py +40 -56
  290. pulumi_oci/visualbuilder/_inputs.py +6 -2
  291. pulumi_oci/visualbuilder/outputs.py +18 -6
  292. pulumi_oci/vnmonitoring/_inputs.py +10 -42
  293. pulumi_oci/vnmonitoring/outputs.py +10 -42
  294. pulumi_oci/vulnerabilityscanning/_inputs.py +4 -4
  295. pulumi_oci/vulnerabilityscanning/container_scan_target.py +7 -7
  296. pulumi_oci/vulnerabilityscanning/outputs.py +4 -4
  297. pulumi_oci/waas/_inputs.py +133 -205
  298. pulumi_oci/waas/outputs.py +133 -205
  299. pulumi_oci/waas/policy.py +7 -7
  300. pulumi_oci/waas/protection_rule.py +7 -7
  301. pulumi_oci/waf/_inputs.py +36 -30
  302. pulumi_oci/waf/network_address_list.py +7 -7
  303. pulumi_oci/waf/outputs.py +36 -30
  304. {pulumi_oci-1.37.0a1715927489.dist-info → pulumi_oci-1.37.0a1716526633.dist-info}/METADATA +1 -1
  305. {pulumi_oci-1.37.0a1715927489.dist-info → pulumi_oci-1.37.0a1716526633.dist-info}/RECORD +307 -296
  306. {pulumi_oci-1.37.0a1715927489.dist-info → pulumi_oci-1.37.0a1716526633.dist-info}/WHEEL +0 -0
  307. {pulumi_oci-1.37.0a1715927489.dist-info → pulumi_oci-1.37.0a1716526633.dist-info}/top_level.txt +0 -0
@@ -562,18 +562,14 @@ class SddcInitialConfigurationInitialClusterConfigurationArgs:
562
562
  :param pulumi.Input[Sequence[pulumi.Input['SddcInitialConfigurationInitialClusterConfigurationDatastoreArgs']]] datastores: A list of datastore info for the Cluster. This value is required only when `initialHostShapeName` is a standard shape.
563
563
  :param pulumi.Input[str] display_name: A descriptive name for the Cluster. Cluster name requirements are 1-16 character length limit, Must start with a letter, Must be English letters, numbers, - only, No repeating hyphens, Must be unique within the region. Avoid entering confidential information.
564
564
  :param pulumi.Input[str] initial_commitment: The billing option selected during Cluster creation. [ListSupportedCommitments](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/SupportedCommitmentSummary/ListSupportedCommitments).
565
- :param pulumi.Input[float] initial_host_ocpu_count: (Optional) The initial OCPU count of the SDDC's ESXi hosts. **Deprecated**. Please use `initial_host_ocpu_count` of `initial_cluster_configurations` instead.
566
- :param pulumi.Input[str] initial_host_shape_name: (Optional) The initial compute shape of the SDDC's ESXi hosts. [ListSupportedHostShapes](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/SupportedHostShapes/ListSupportedHostShapes). **Deprecated**. Please use `initial_host_shape_name` of `initial_cluster_configurations` instead.
567
- :param pulumi.Input[str] instance_display_name_prefix: (Optional) A prefix used in the name of each ESXi host and Compute instance in the SDDC. If this isn't set, the SDDC's `displayName` is used as the prefix.
565
+ :param pulumi.Input[float] initial_host_ocpu_count: The initial OCPU count of the Cluster's ESXi hosts.
566
+ :param pulumi.Input[str] initial_host_shape_name: The initial compute shape of the Cluster's ESXi hosts. [ListSupportedHostShapes](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/SupportedHostShapes/ListSupportedHostShapes).
567
+ :param pulumi.Input[str] instance_display_name_prefix: A prefix used in the name of each ESXi host and Compute instance in the Cluster. If this isn't set, the Cluster's `displayName` is used as the prefix.
568
568
 
569
- For example, if the value is `mySDDC`, the ESXi hosts are named `mySDDC-1`, `mySDDC-2`, and so on. **Deprecated**. Please use `instance_display_name_prefix` of `initial_cluster_configurations` instead.
570
- :param pulumi.Input[bool] is_shielded_instance_enabled: (Optional) Indicates whether shielded instance is enabled for this SDDC. **Deprecated**. Please use `is_shielded_instance_enabled` of `initial_cluster_configurations` instead.
569
+ For example, if the value is `myCluster`, the ESXi hosts are named `myCluster-1`, `myCluster-2`, and so on.
570
+ :param pulumi.Input[bool] is_shielded_instance_enabled: Indicates whether shielded instance is enabled for this Cluster.
571
571
  :param pulumi.Input['SddcInitialConfigurationInitialClusterConfigurationNetworkConfigurationArgs'] network_configuration: The network configurations used by Cluster, including [OCIDs](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the management subnet and VLANs.
572
- :param pulumi.Input[str] workload_network_cidr: (Optional) The CIDR block for the IP addresses that VMware VMs in the SDDC use to run application workloads. **Deprecated**. Please use `workload_network_cidr` of `initial_cluster_configurations` instead.
573
-
574
-
575
- ** IMPORTANT **
576
- Any change to a property that does not support update will force the destruction and recreation of the resource with the new property values
572
+ :param pulumi.Input[str] workload_network_cidr: The CIDR block for the IP addresses that VMware VMs in the Cluster use to run application workloads.
577
573
  """
578
574
  pulumi.set(__self__, "compute_availability_domain", compute_availability_domain)
579
575
  pulumi.set(__self__, "esxi_hosts_count", esxi_hosts_count)
@@ -703,7 +699,7 @@ class SddcInitialConfigurationInitialClusterConfigurationArgs:
703
699
  @pulumi.getter(name="initialHostOcpuCount")
704
700
  def initial_host_ocpu_count(self) -> Optional[pulumi.Input[float]]:
705
701
  """
706
- (Optional) The initial OCPU count of the SDDC's ESXi hosts. **Deprecated**. Please use `initial_host_ocpu_count` of `initial_cluster_configurations` instead.
702
+ The initial OCPU count of the Cluster's ESXi hosts.
707
703
  """
708
704
  return pulumi.get(self, "initial_host_ocpu_count")
709
705
 
@@ -715,7 +711,7 @@ class SddcInitialConfigurationInitialClusterConfigurationArgs:
715
711
  @pulumi.getter(name="initialHostShapeName")
716
712
  def initial_host_shape_name(self) -> Optional[pulumi.Input[str]]:
717
713
  """
718
- (Optional) The initial compute shape of the SDDC's ESXi hosts. [ListSupportedHostShapes](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/SupportedHostShapes/ListSupportedHostShapes). **Deprecated**. Please use `initial_host_shape_name` of `initial_cluster_configurations` instead.
714
+ The initial compute shape of the Cluster's ESXi hosts. [ListSupportedHostShapes](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/SupportedHostShapes/ListSupportedHostShapes).
719
715
  """
720
716
  return pulumi.get(self, "initial_host_shape_name")
721
717
 
@@ -727,9 +723,9 @@ class SddcInitialConfigurationInitialClusterConfigurationArgs:
727
723
  @pulumi.getter(name="instanceDisplayNamePrefix")
728
724
  def instance_display_name_prefix(self) -> Optional[pulumi.Input[str]]:
729
725
  """
730
- (Optional) A prefix used in the name of each ESXi host and Compute instance in the SDDC. If this isn't set, the SDDC's `displayName` is used as the prefix.
726
+ A prefix used in the name of each ESXi host and Compute instance in the Cluster. If this isn't set, the Cluster's `displayName` is used as the prefix.
731
727
 
732
- For example, if the value is `mySDDC`, the ESXi hosts are named `mySDDC-1`, `mySDDC-2`, and so on. **Deprecated**. Please use `instance_display_name_prefix` of `initial_cluster_configurations` instead.
728
+ For example, if the value is `myCluster`, the ESXi hosts are named `myCluster-1`, `myCluster-2`, and so on.
733
729
  """
734
730
  return pulumi.get(self, "instance_display_name_prefix")
735
731
 
@@ -741,7 +737,7 @@ class SddcInitialConfigurationInitialClusterConfigurationArgs:
741
737
  @pulumi.getter(name="isShieldedInstanceEnabled")
742
738
  def is_shielded_instance_enabled(self) -> Optional[pulumi.Input[bool]]:
743
739
  """
744
- (Optional) Indicates whether shielded instance is enabled for this SDDC. **Deprecated**. Please use `is_shielded_instance_enabled` of `initial_cluster_configurations` instead.
740
+ Indicates whether shielded instance is enabled for this Cluster.
745
741
  """
746
742
  return pulumi.get(self, "is_shielded_instance_enabled")
747
743
 
@@ -765,11 +761,7 @@ class SddcInitialConfigurationInitialClusterConfigurationArgs:
765
761
  @pulumi.getter(name="workloadNetworkCidr")
766
762
  def workload_network_cidr(self) -> Optional[pulumi.Input[str]]:
767
763
  """
768
- (Optional) The CIDR block for the IP addresses that VMware VMs in the SDDC use to run application workloads. **Deprecated**. Please use `workload_network_cidr` of `initial_cluster_configurations` instead.
769
-
770
-
771
- ** IMPORTANT **
772
- Any change to a property that does not support update will force the destruction and recreation of the resource with the new property values
764
+ The CIDR block for the IP addresses that VMware VMs in the Cluster use to run application workloads.
773
765
  """
774
766
  return pulumi.get(self, "workload_network_cidr")
775
767
 
@@ -830,23 +822,49 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfigurationArg
830
822
  replication_vlan_id: Optional[pulumi.Input[str]] = None,
831
823
  vsphere_vlan_id: Optional[pulumi.Input[str]] = None):
832
824
  """
833
- :param pulumi.Input[str] nsx_edge_vtep_vlan_id: (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX Edge VTEP component of the VMware environment. **Deprecated**. Please use `nsx_edge_vtep_vlan_id` of `network_configuration` instead.
834
- :param pulumi.Input[str] nsx_vtep_vlan_id: (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX VTEP component of the VMware environment. **Deprecated**. Please use `nsx_vtep_vlan_id` of `network_configuration` instead.
835
- :param pulumi.Input[str] provisioning_subnet_id: (Required) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the management subnet to use for provisioning the SDDC. **Deprecated**. Please use `provisioning_subnet_id` of `network_configuration` instead.
836
- :param pulumi.Input[str] vmotion_vlan_id: (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the vMotion component of the VMware environment. **Deprecated**. Please use `vmotion_vlan_id` of `network_configuration` instead.
837
- :param pulumi.Input[str] vsan_vlan_id: (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the vSAN component of the VMware environment. **Deprecated**. Please use `vsan_vlan_id` of `network_configuration` instead.
825
+ :param pulumi.Input[str] nsx_edge_vtep_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the NSX Edge VTEP component of the VMware environment.
826
+
827
+ This attribute is not guaranteed to reflect the NSX Edge VTEP VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX Edge VTEP VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
828
+
829
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX Edge VTEP component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxEdgeVTepVlanId` with that new VLAN's OCID.
830
+ :param pulumi.Input[str] nsx_vtep_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the NSX VTEP component of the VMware environment.
831
+
832
+ This attribute is not guaranteed to reflect the NSX VTEP VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX VTEP VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
833
+
834
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX VTEP component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxVTepVlanId` with that new VLAN's OCID.
835
+ :param pulumi.Input[str] provisioning_subnet_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the management subnet used to provision the Cluster.
836
+ :param pulumi.Input[str] vmotion_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the vMotion component of the VMware environment.
837
+
838
+ This attribute is not guaranteed to reflect the vMotion VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the vMotion VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
839
+
840
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the vMotion component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Sddc/UpdateCluster) to update the Cluster's `vmotionVlanId` with that new VLAN's OCID.
841
+ :param pulumi.Input[str] vsan_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the vSAN component of the VMware environment.
842
+
843
+ This attribute is not guaranteed to reflect the vSAN VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the vSAN VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
844
+
845
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the vSAN component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `vsanVlanId` with that new VLAN's OCID.
838
846
  :param pulumi.Input[str] hcx_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the HCX component of the VMware environment. This VLAN is a mandatory attribute for Management Cluster when HCX is enabled.
839
847
 
840
848
  This attribute is not guaranteed to reflect the HCX VLAN currently used by the ESXi hosts in the SDDC. The purpose of this attribute is to show the HCX VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this SDDC in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20230701/EsxiHost/CreateEsxiHost).
841
849
 
842
850
  Therefore, if you change the existing ESXi hosts in the SDDC to use a different VLAN for the HCX component of the VMware environment, you should use [UpdateSddc](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20230701/Sddc/UpdateSddc) to update the SDDC's `hcxVlanId` with that new VLAN's OCID.
843
- :param pulumi.Input[str] nsx_edge_uplink1vlan_id: (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX Edge Uplink 1 component of the VMware environment. **Deprecated**. Please use `nsx_edge_uplink1vlan_id` of `network_configuration` instead.
844
- :param pulumi.Input[str] nsx_edge_uplink2vlan_id: (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX Edge Uplink 2 component of the VMware environment. **Deprecated**. Please use `nsx_edge_uplink2vlan_id` of `network_configuration` instead.
851
+ :param pulumi.Input[str] nsx_edge_uplink1vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the NSX Edge Uplink 1 component of the VMware environment. This VLAN is a mandatory attribute for Management Cluster.
852
+
853
+ This attribute is not guaranteed to reflect the NSX Edge Uplink 1 VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX Edge Uplink 1 VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
854
+
855
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX Edge Uplink 1 component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxEdgeUplink1VlanId` with that new VLAN's OCID.
856
+ :param pulumi.Input[str] nsx_edge_uplink2vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the NSX Edge Uplink 2 component of the VMware environment. This VLAN is a mandatory attribute for Management Cluster.
857
+
858
+ This attribute is not guaranteed to reflect the NSX Edge Uplink 2 VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX Edge Uplink 2 VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
859
+
860
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX Edge Uplink 2 component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxEdgeUplink2VlanId` with that new VLAN's OCID.
861
+ :param pulumi.Input[str] provisioning_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the Provisioning component of the VMware environment.
862
+ :param pulumi.Input[str] replication_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the vSphere Replication component of the VMware environment.
863
+ :param pulumi.Input[str] vsphere_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the vSphere component of the VMware environment. This VLAN is a mandatory attribute for Management Cluster.
864
+
865
+ This attribute is not guaranteed to reflect the vSphere VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the vSphere VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
845
866
 
846
- **Note:** This VLAN is reserved for future use to deploy public-facing applications on the VMware SDDC.
847
- :param pulumi.Input[str] provisioning_vlan_id: (Optional) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the Provisioning component of the VMware environment. **Deprecated**. Please use `provisioning_vlan_id` of `network_configuration` instead.
848
- :param pulumi.Input[str] replication_vlan_id: (Optional) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the vSphere Replication component of the VMware environment. **Deprecated**. Please use `replication_vlan_id` of `network_configuration` instead.
849
- :param pulumi.Input[str] vsphere_vlan_id: (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the vSphere component of the VMware environment. **Deprecated**. Please use `vsphere_vlan_id` of `network_configuration` instead.
867
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the vSphere component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Sddc/UpdateSddc) to update the Cluster's `vsphereVlanId` with that new VLAN's OCID.
850
868
  """
851
869
  pulumi.set(__self__, "nsx_edge_vtep_vlan_id", nsx_edge_vtep_vlan_id)
852
870
  pulumi.set(__self__, "nsx_vtep_vlan_id", nsx_vtep_vlan_id)
@@ -870,7 +888,11 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfigurationArg
870
888
  @pulumi.getter(name="nsxEdgeVtepVlanId")
871
889
  def nsx_edge_vtep_vlan_id(self) -> pulumi.Input[str]:
872
890
  """
873
- (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX Edge VTEP component of the VMware environment. **Deprecated**. Please use `nsx_edge_vtep_vlan_id` of `network_configuration` instead.
891
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the NSX Edge VTEP component of the VMware environment.
892
+
893
+ This attribute is not guaranteed to reflect the NSX Edge VTEP VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX Edge VTEP VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
894
+
895
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX Edge VTEP component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxEdgeVTepVlanId` with that new VLAN's OCID.
874
896
  """
875
897
  return pulumi.get(self, "nsx_edge_vtep_vlan_id")
876
898
 
@@ -882,7 +904,11 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfigurationArg
882
904
  @pulumi.getter(name="nsxVtepVlanId")
883
905
  def nsx_vtep_vlan_id(self) -> pulumi.Input[str]:
884
906
  """
885
- (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX VTEP component of the VMware environment. **Deprecated**. Please use `nsx_vtep_vlan_id` of `network_configuration` instead.
907
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the NSX VTEP component of the VMware environment.
908
+
909
+ This attribute is not guaranteed to reflect the NSX VTEP VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX VTEP VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
910
+
911
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX VTEP component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxVTepVlanId` with that new VLAN's OCID.
886
912
  """
887
913
  return pulumi.get(self, "nsx_vtep_vlan_id")
888
914
 
@@ -894,7 +920,7 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfigurationArg
894
920
  @pulumi.getter(name="provisioningSubnetId")
895
921
  def provisioning_subnet_id(self) -> pulumi.Input[str]:
896
922
  """
897
- (Required) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the management subnet to use for provisioning the SDDC. **Deprecated**. Please use `provisioning_subnet_id` of `network_configuration` instead.
923
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the management subnet used to provision the Cluster.
898
924
  """
899
925
  return pulumi.get(self, "provisioning_subnet_id")
900
926
 
@@ -906,7 +932,11 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfigurationArg
906
932
  @pulumi.getter(name="vmotionVlanId")
907
933
  def vmotion_vlan_id(self) -> pulumi.Input[str]:
908
934
  """
909
- (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the vMotion component of the VMware environment. **Deprecated**. Please use `vmotion_vlan_id` of `network_configuration` instead.
935
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the vMotion component of the VMware environment.
936
+
937
+ This attribute is not guaranteed to reflect the vMotion VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the vMotion VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
938
+
939
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the vMotion component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Sddc/UpdateCluster) to update the Cluster's `vmotionVlanId` with that new VLAN's OCID.
910
940
  """
911
941
  return pulumi.get(self, "vmotion_vlan_id")
912
942
 
@@ -918,7 +948,11 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfigurationArg
918
948
  @pulumi.getter(name="vsanVlanId")
919
949
  def vsan_vlan_id(self) -> pulumi.Input[str]:
920
950
  """
921
- (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the vSAN component of the VMware environment. **Deprecated**. Please use `vsan_vlan_id` of `network_configuration` instead.
951
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the vSAN component of the VMware environment.
952
+
953
+ This attribute is not guaranteed to reflect the vSAN VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the vSAN VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
954
+
955
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the vSAN component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `vsanVlanId` with that new VLAN's OCID.
922
956
  """
923
957
  return pulumi.get(self, "vsan_vlan_id")
924
958
 
@@ -946,7 +980,11 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfigurationArg
946
980
  @pulumi.getter(name="nsxEdgeUplink1vlanId")
947
981
  def nsx_edge_uplink1vlan_id(self) -> Optional[pulumi.Input[str]]:
948
982
  """
949
- (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX Edge Uplink 1 component of the VMware environment. **Deprecated**. Please use `nsx_edge_uplink1vlan_id` of `network_configuration` instead.
983
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the NSX Edge Uplink 1 component of the VMware environment. This VLAN is a mandatory attribute for Management Cluster.
984
+
985
+ This attribute is not guaranteed to reflect the NSX Edge Uplink 1 VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX Edge Uplink 1 VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
986
+
987
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX Edge Uplink 1 component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxEdgeUplink1VlanId` with that new VLAN's OCID.
950
988
  """
951
989
  return pulumi.get(self, "nsx_edge_uplink1vlan_id")
952
990
 
@@ -958,9 +996,11 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfigurationArg
958
996
  @pulumi.getter(name="nsxEdgeUplink2vlanId")
959
997
  def nsx_edge_uplink2vlan_id(self) -> Optional[pulumi.Input[str]]:
960
998
  """
961
- (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX Edge Uplink 2 component of the VMware environment. **Deprecated**. Please use `nsx_edge_uplink2vlan_id` of `network_configuration` instead.
999
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the NSX Edge Uplink 2 component of the VMware environment. This VLAN is a mandatory attribute for Management Cluster.
962
1000
 
963
- **Note:** This VLAN is reserved for future use to deploy public-facing applications on the VMware SDDC.
1001
+ This attribute is not guaranteed to reflect the NSX Edge Uplink 2 VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX Edge Uplink 2 VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
1002
+
1003
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX Edge Uplink 2 component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxEdgeUplink2VlanId` with that new VLAN's OCID.
964
1004
  """
965
1005
  return pulumi.get(self, "nsx_edge_uplink2vlan_id")
966
1006
 
@@ -972,7 +1012,7 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfigurationArg
972
1012
  @pulumi.getter(name="provisioningVlanId")
973
1013
  def provisioning_vlan_id(self) -> Optional[pulumi.Input[str]]:
974
1014
  """
975
- (Optional) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the Provisioning component of the VMware environment. **Deprecated**. Please use `provisioning_vlan_id` of `network_configuration` instead.
1015
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the Provisioning component of the VMware environment.
976
1016
  """
977
1017
  return pulumi.get(self, "provisioning_vlan_id")
978
1018
 
@@ -984,7 +1024,7 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfigurationArg
984
1024
  @pulumi.getter(name="replicationVlanId")
985
1025
  def replication_vlan_id(self) -> Optional[pulumi.Input[str]]:
986
1026
  """
987
- (Optional) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the vSphere Replication component of the VMware environment. **Deprecated**. Please use `replication_vlan_id` of `network_configuration` instead.
1027
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the vSphere Replication component of the VMware environment.
988
1028
  """
989
1029
  return pulumi.get(self, "replication_vlan_id")
990
1030
 
@@ -996,7 +1036,11 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfigurationArg
996
1036
  @pulumi.getter(name="vsphereVlanId")
997
1037
  def vsphere_vlan_id(self) -> Optional[pulumi.Input[str]]:
998
1038
  """
999
- (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the vSphere component of the VMware environment. **Deprecated**. Please use `vsphere_vlan_id` of `network_configuration` instead.
1039
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the vSphere component of the VMware environment. This VLAN is a mandatory attribute for Management Cluster.
1040
+
1041
+ This attribute is not guaranteed to reflect the vSphere VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the vSphere VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
1042
+
1043
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the vSphere component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Sddc/UpdateSddc) to update the Cluster's `vsphereVlanId` with that new VLAN's OCID.
1000
1044
  """
1001
1045
  return pulumi.get(self, "vsphere_vlan_id")
1002
1046
 
@@ -53,6 +53,7 @@ class GetRetrievePasswordResult:
53
53
  def sddc_password(self) -> Mapping[str, Any]:
54
54
  """
55
55
  SDDC vCenter/NSX/HCX password.
56
+ * `passwordType` - SDDC password type.
56
57
  """
57
58
  return pulumi.get(self, "sddc_password")
58
59
 
@@ -686,18 +686,14 @@ class SddcInitialConfigurationInitialClusterConfiguration(dict):
686
686
  :param Sequence['SddcInitialConfigurationInitialClusterConfigurationDatastoreArgs'] datastores: A list of datastore info for the Cluster. This value is required only when `initialHostShapeName` is a standard shape.
687
687
  :param str display_name: A descriptive name for the Cluster. Cluster name requirements are 1-16 character length limit, Must start with a letter, Must be English letters, numbers, - only, No repeating hyphens, Must be unique within the region. Avoid entering confidential information.
688
688
  :param str initial_commitment: The billing option selected during Cluster creation. [ListSupportedCommitments](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/SupportedCommitmentSummary/ListSupportedCommitments).
689
- :param float initial_host_ocpu_count: (Optional) The initial OCPU count of the SDDC's ESXi hosts. **Deprecated**. Please use `initial_host_ocpu_count` of `initial_cluster_configurations` instead.
690
- :param str initial_host_shape_name: (Optional) The initial compute shape of the SDDC's ESXi hosts. [ListSupportedHostShapes](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/SupportedHostShapes/ListSupportedHostShapes). **Deprecated**. Please use `initial_host_shape_name` of `initial_cluster_configurations` instead.
691
- :param str instance_display_name_prefix: (Optional) A prefix used in the name of each ESXi host and Compute instance in the SDDC. If this isn't set, the SDDC's `displayName` is used as the prefix.
689
+ :param float initial_host_ocpu_count: The initial OCPU count of the Cluster's ESXi hosts.
690
+ :param str initial_host_shape_name: The initial compute shape of the Cluster's ESXi hosts. [ListSupportedHostShapes](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/SupportedHostShapes/ListSupportedHostShapes).
691
+ :param str instance_display_name_prefix: A prefix used in the name of each ESXi host and Compute instance in the Cluster. If this isn't set, the Cluster's `displayName` is used as the prefix.
692
692
 
693
- For example, if the value is `mySDDC`, the ESXi hosts are named `mySDDC-1`, `mySDDC-2`, and so on. **Deprecated**. Please use `instance_display_name_prefix` of `initial_cluster_configurations` instead.
694
- :param bool is_shielded_instance_enabled: (Optional) Indicates whether shielded instance is enabled for this SDDC. **Deprecated**. Please use `is_shielded_instance_enabled` of `initial_cluster_configurations` instead.
693
+ For example, if the value is `myCluster`, the ESXi hosts are named `myCluster-1`, `myCluster-2`, and so on.
694
+ :param bool is_shielded_instance_enabled: Indicates whether shielded instance is enabled for this Cluster.
695
695
  :param 'SddcInitialConfigurationInitialClusterConfigurationNetworkConfigurationArgs' network_configuration: The network configurations used by Cluster, including [OCIDs](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the management subnet and VLANs.
696
- :param str workload_network_cidr: (Optional) The CIDR block for the IP addresses that VMware VMs in the SDDC use to run application workloads. **Deprecated**. Please use `workload_network_cidr` of `initial_cluster_configurations` instead.
697
-
698
-
699
- ** IMPORTANT **
700
- Any change to a property that does not support update will force the destruction and recreation of the resource with the new property values
696
+ :param str workload_network_cidr: The CIDR block for the IP addresses that VMware VMs in the Cluster use to run application workloads.
701
697
  """
702
698
  pulumi.set(__self__, "compute_availability_domain", compute_availability_domain)
703
699
  pulumi.set(__self__, "esxi_hosts_count", esxi_hosts_count)
@@ -795,7 +791,7 @@ class SddcInitialConfigurationInitialClusterConfiguration(dict):
795
791
  @pulumi.getter(name="initialHostOcpuCount")
796
792
  def initial_host_ocpu_count(self) -> Optional[float]:
797
793
  """
798
- (Optional) The initial OCPU count of the SDDC's ESXi hosts. **Deprecated**. Please use `initial_host_ocpu_count` of `initial_cluster_configurations` instead.
794
+ The initial OCPU count of the Cluster's ESXi hosts.
799
795
  """
800
796
  return pulumi.get(self, "initial_host_ocpu_count")
801
797
 
@@ -803,7 +799,7 @@ class SddcInitialConfigurationInitialClusterConfiguration(dict):
803
799
  @pulumi.getter(name="initialHostShapeName")
804
800
  def initial_host_shape_name(self) -> Optional[str]:
805
801
  """
806
- (Optional) The initial compute shape of the SDDC's ESXi hosts. [ListSupportedHostShapes](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/SupportedHostShapes/ListSupportedHostShapes). **Deprecated**. Please use `initial_host_shape_name` of `initial_cluster_configurations` instead.
802
+ The initial compute shape of the Cluster's ESXi hosts. [ListSupportedHostShapes](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/SupportedHostShapes/ListSupportedHostShapes).
807
803
  """
808
804
  return pulumi.get(self, "initial_host_shape_name")
809
805
 
@@ -811,9 +807,9 @@ class SddcInitialConfigurationInitialClusterConfiguration(dict):
811
807
  @pulumi.getter(name="instanceDisplayNamePrefix")
812
808
  def instance_display_name_prefix(self) -> Optional[str]:
813
809
  """
814
- (Optional) A prefix used in the name of each ESXi host and Compute instance in the SDDC. If this isn't set, the SDDC's `displayName` is used as the prefix.
810
+ A prefix used in the name of each ESXi host and Compute instance in the Cluster. If this isn't set, the Cluster's `displayName` is used as the prefix.
815
811
 
816
- For example, if the value is `mySDDC`, the ESXi hosts are named `mySDDC-1`, `mySDDC-2`, and so on. **Deprecated**. Please use `instance_display_name_prefix` of `initial_cluster_configurations` instead.
812
+ For example, if the value is `myCluster`, the ESXi hosts are named `myCluster-1`, `myCluster-2`, and so on.
817
813
  """
818
814
  return pulumi.get(self, "instance_display_name_prefix")
819
815
 
@@ -821,7 +817,7 @@ class SddcInitialConfigurationInitialClusterConfiguration(dict):
821
817
  @pulumi.getter(name="isShieldedInstanceEnabled")
822
818
  def is_shielded_instance_enabled(self) -> Optional[bool]:
823
819
  """
824
- (Optional) Indicates whether shielded instance is enabled for this SDDC. **Deprecated**. Please use `is_shielded_instance_enabled` of `initial_cluster_configurations` instead.
820
+ Indicates whether shielded instance is enabled for this Cluster.
825
821
  """
826
822
  return pulumi.get(self, "is_shielded_instance_enabled")
827
823
 
@@ -837,11 +833,7 @@ class SddcInitialConfigurationInitialClusterConfiguration(dict):
837
833
  @pulumi.getter(name="workloadNetworkCidr")
838
834
  def workload_network_cidr(self) -> Optional[str]:
839
835
  """
840
- (Optional) The CIDR block for the IP addresses that VMware VMs in the SDDC use to run application workloads. **Deprecated**. Please use `workload_network_cidr` of `initial_cluster_configurations` instead.
841
-
842
-
843
- ** IMPORTANT **
844
- Any change to a property that does not support update will force the destruction and recreation of the resource with the new property values
836
+ The CIDR block for the IP addresses that VMware VMs in the Cluster use to run application workloads.
845
837
  """
846
838
  return pulumi.get(self, "workload_network_cidr")
847
839
 
@@ -946,23 +938,49 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfiguration(di
946
938
  replication_vlan_id: Optional[str] = None,
947
939
  vsphere_vlan_id: Optional[str] = None):
948
940
  """
949
- :param str nsx_edge_vtep_vlan_id: (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX Edge VTEP component of the VMware environment. **Deprecated**. Please use `nsx_edge_vtep_vlan_id` of `network_configuration` instead.
950
- :param str nsx_vtep_vlan_id: (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX VTEP component of the VMware environment. **Deprecated**. Please use `nsx_vtep_vlan_id` of `network_configuration` instead.
951
- :param str provisioning_subnet_id: (Required) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the management subnet to use for provisioning the SDDC. **Deprecated**. Please use `provisioning_subnet_id` of `network_configuration` instead.
952
- :param str vmotion_vlan_id: (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the vMotion component of the VMware environment. **Deprecated**. Please use `vmotion_vlan_id` of `network_configuration` instead.
953
- :param str vsan_vlan_id: (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the vSAN component of the VMware environment. **Deprecated**. Please use `vsan_vlan_id` of `network_configuration` instead.
941
+ :param str nsx_edge_vtep_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the NSX Edge VTEP component of the VMware environment.
942
+
943
+ This attribute is not guaranteed to reflect the NSX Edge VTEP VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX Edge VTEP VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
944
+
945
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX Edge VTEP component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxEdgeVTepVlanId` with that new VLAN's OCID.
946
+ :param str nsx_vtep_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the NSX VTEP component of the VMware environment.
947
+
948
+ This attribute is not guaranteed to reflect the NSX VTEP VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX VTEP VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
949
+
950
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX VTEP component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxVTepVlanId` with that new VLAN's OCID.
951
+ :param str provisioning_subnet_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the management subnet used to provision the Cluster.
952
+ :param str vmotion_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the vMotion component of the VMware environment.
953
+
954
+ This attribute is not guaranteed to reflect the vMotion VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the vMotion VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
955
+
956
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the vMotion component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Sddc/UpdateCluster) to update the Cluster's `vmotionVlanId` with that new VLAN's OCID.
957
+ :param str vsan_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the vSAN component of the VMware environment.
958
+
959
+ This attribute is not guaranteed to reflect the vSAN VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the vSAN VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
960
+
961
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the vSAN component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `vsanVlanId` with that new VLAN's OCID.
954
962
  :param str hcx_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the HCX component of the VMware environment. This VLAN is a mandatory attribute for Management Cluster when HCX is enabled.
955
963
 
956
964
  This attribute is not guaranteed to reflect the HCX VLAN currently used by the ESXi hosts in the SDDC. The purpose of this attribute is to show the HCX VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this SDDC in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20230701/EsxiHost/CreateEsxiHost).
957
965
 
958
966
  Therefore, if you change the existing ESXi hosts in the SDDC to use a different VLAN for the HCX component of the VMware environment, you should use [UpdateSddc](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20230701/Sddc/UpdateSddc) to update the SDDC's `hcxVlanId` with that new VLAN's OCID.
959
- :param str nsx_edge_uplink1vlan_id: (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX Edge Uplink 1 component of the VMware environment. **Deprecated**. Please use `nsx_edge_uplink1vlan_id` of `network_configuration` instead.
960
- :param str nsx_edge_uplink2vlan_id: (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX Edge Uplink 2 component of the VMware environment. **Deprecated**. Please use `nsx_edge_uplink2vlan_id` of `network_configuration` instead.
967
+ :param str nsx_edge_uplink1vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the NSX Edge Uplink 1 component of the VMware environment. This VLAN is a mandatory attribute for Management Cluster.
968
+
969
+ This attribute is not guaranteed to reflect the NSX Edge Uplink 1 VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX Edge Uplink 1 VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
970
+
971
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX Edge Uplink 1 component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxEdgeUplink1VlanId` with that new VLAN's OCID.
972
+ :param str nsx_edge_uplink2vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the NSX Edge Uplink 2 component of the VMware environment. This VLAN is a mandatory attribute for Management Cluster.
973
+
974
+ This attribute is not guaranteed to reflect the NSX Edge Uplink 2 VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX Edge Uplink 2 VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
975
+
976
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX Edge Uplink 2 component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxEdgeUplink2VlanId` with that new VLAN's OCID.
977
+ :param str provisioning_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the Provisioning component of the VMware environment.
978
+ :param str replication_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the vSphere Replication component of the VMware environment.
979
+ :param str vsphere_vlan_id: The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the vSphere component of the VMware environment. This VLAN is a mandatory attribute for Management Cluster.
980
+
981
+ This attribute is not guaranteed to reflect the vSphere VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the vSphere VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
961
982
 
962
- **Note:** This VLAN is reserved for future use to deploy public-facing applications on the VMware SDDC.
963
- :param str provisioning_vlan_id: (Optional) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the Provisioning component of the VMware environment. **Deprecated**. Please use `provisioning_vlan_id` of `network_configuration` instead.
964
- :param str replication_vlan_id: (Optional) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the vSphere Replication component of the VMware environment. **Deprecated**. Please use `replication_vlan_id` of `network_configuration` instead.
965
- :param str vsphere_vlan_id: (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the vSphere component of the VMware environment. **Deprecated**. Please use `vsphere_vlan_id` of `network_configuration` instead.
983
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the vSphere component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Sddc/UpdateSddc) to update the Cluster's `vsphereVlanId` with that new VLAN's OCID.
966
984
  """
967
985
  pulumi.set(__self__, "nsx_edge_vtep_vlan_id", nsx_edge_vtep_vlan_id)
968
986
  pulumi.set(__self__, "nsx_vtep_vlan_id", nsx_vtep_vlan_id)
@@ -986,7 +1004,11 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfiguration(di
986
1004
  @pulumi.getter(name="nsxEdgeVtepVlanId")
987
1005
  def nsx_edge_vtep_vlan_id(self) -> str:
988
1006
  """
989
- (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX Edge VTEP component of the VMware environment. **Deprecated**. Please use `nsx_edge_vtep_vlan_id` of `network_configuration` instead.
1007
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the NSX Edge VTEP component of the VMware environment.
1008
+
1009
+ This attribute is not guaranteed to reflect the NSX Edge VTEP VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX Edge VTEP VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
1010
+
1011
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX Edge VTEP component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxEdgeVTepVlanId` with that new VLAN's OCID.
990
1012
  """
991
1013
  return pulumi.get(self, "nsx_edge_vtep_vlan_id")
992
1014
 
@@ -994,7 +1016,11 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfiguration(di
994
1016
  @pulumi.getter(name="nsxVtepVlanId")
995
1017
  def nsx_vtep_vlan_id(self) -> str:
996
1018
  """
997
- (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX VTEP component of the VMware environment. **Deprecated**. Please use `nsx_vtep_vlan_id` of `network_configuration` instead.
1019
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the NSX VTEP component of the VMware environment.
1020
+
1021
+ This attribute is not guaranteed to reflect the NSX VTEP VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX VTEP VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
1022
+
1023
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX VTEP component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxVTepVlanId` with that new VLAN's OCID.
998
1024
  """
999
1025
  return pulumi.get(self, "nsx_vtep_vlan_id")
1000
1026
 
@@ -1002,7 +1028,7 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfiguration(di
1002
1028
  @pulumi.getter(name="provisioningSubnetId")
1003
1029
  def provisioning_subnet_id(self) -> str:
1004
1030
  """
1005
- (Required) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the management subnet to use for provisioning the SDDC. **Deprecated**. Please use `provisioning_subnet_id` of `network_configuration` instead.
1031
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the management subnet used to provision the Cluster.
1006
1032
  """
1007
1033
  return pulumi.get(self, "provisioning_subnet_id")
1008
1034
 
@@ -1010,7 +1036,11 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfiguration(di
1010
1036
  @pulumi.getter(name="vmotionVlanId")
1011
1037
  def vmotion_vlan_id(self) -> str:
1012
1038
  """
1013
- (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the vMotion component of the VMware environment. **Deprecated**. Please use `vmotion_vlan_id` of `network_configuration` instead.
1039
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the vMotion component of the VMware environment.
1040
+
1041
+ This attribute is not guaranteed to reflect the vMotion VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the vMotion VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
1042
+
1043
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the vMotion component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Sddc/UpdateCluster) to update the Cluster's `vmotionVlanId` with that new VLAN's OCID.
1014
1044
  """
1015
1045
  return pulumi.get(self, "vmotion_vlan_id")
1016
1046
 
@@ -1018,7 +1048,11 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfiguration(di
1018
1048
  @pulumi.getter(name="vsanVlanId")
1019
1049
  def vsan_vlan_id(self) -> str:
1020
1050
  """
1021
- (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the vSAN component of the VMware environment. **Deprecated**. Please use `vsan_vlan_id` of `network_configuration` instead.
1051
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the vSAN component of the VMware environment.
1052
+
1053
+ This attribute is not guaranteed to reflect the vSAN VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the vSAN VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
1054
+
1055
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the vSAN component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `vsanVlanId` with that new VLAN's OCID.
1022
1056
  """
1023
1057
  return pulumi.get(self, "vsan_vlan_id")
1024
1058
 
@@ -1038,7 +1072,11 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfiguration(di
1038
1072
  @pulumi.getter(name="nsxEdgeUplink1vlanId")
1039
1073
  def nsx_edge_uplink1vlan_id(self) -> Optional[str]:
1040
1074
  """
1041
- (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX Edge Uplink 1 component of the VMware environment. **Deprecated**. Please use `nsx_edge_uplink1vlan_id` of `network_configuration` instead.
1075
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the NSX Edge Uplink 1 component of the VMware environment. This VLAN is a mandatory attribute for Management Cluster.
1076
+
1077
+ This attribute is not guaranteed to reflect the NSX Edge Uplink 1 VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX Edge Uplink 1 VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
1078
+
1079
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX Edge Uplink 1 component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxEdgeUplink1VlanId` with that new VLAN's OCID.
1042
1080
  """
1043
1081
  return pulumi.get(self, "nsx_edge_uplink1vlan_id")
1044
1082
 
@@ -1046,9 +1084,11 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfiguration(di
1046
1084
  @pulumi.getter(name="nsxEdgeUplink2vlanId")
1047
1085
  def nsx_edge_uplink2vlan_id(self) -> Optional[str]:
1048
1086
  """
1049
- (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the NSX Edge Uplink 2 component of the VMware environment. **Deprecated**. Please use `nsx_edge_uplink2vlan_id` of `network_configuration` instead.
1087
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the NSX Edge Uplink 2 component of the VMware environment. This VLAN is a mandatory attribute for Management Cluster.
1050
1088
 
1051
- **Note:** This VLAN is reserved for future use to deploy public-facing applications on the VMware SDDC.
1089
+ This attribute is not guaranteed to reflect the NSX Edge Uplink 2 VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the NSX Edge Uplink 2 VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
1090
+
1091
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the NSX Edge Uplink 2 component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Cluster/UpdateCluster) to update the Cluster's `nsxEdgeUplink2VlanId` with that new VLAN's OCID.
1052
1092
  """
1053
1093
  return pulumi.get(self, "nsx_edge_uplink2vlan_id")
1054
1094
 
@@ -1056,7 +1096,7 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfiguration(di
1056
1096
  @pulumi.getter(name="provisioningVlanId")
1057
1097
  def provisioning_vlan_id(self) -> Optional[str]:
1058
1098
  """
1059
- (Optional) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the Provisioning component of the VMware environment. **Deprecated**. Please use `provisioning_vlan_id` of `network_configuration` instead.
1099
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the Provisioning component of the VMware environment.
1060
1100
  """
1061
1101
  return pulumi.get(self, "provisioning_vlan_id")
1062
1102
 
@@ -1064,7 +1104,7 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfiguration(di
1064
1104
  @pulumi.getter(name="replicationVlanId")
1065
1105
  def replication_vlan_id(self) -> Optional[str]:
1066
1106
  """
1067
- (Optional) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the vSphere Replication component of the VMware environment. **Deprecated**. Please use `replication_vlan_id` of `network_configuration` instead.
1107
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the Cluster for the vSphere Replication component of the VMware environment.
1068
1108
  """
1069
1109
  return pulumi.get(self, "replication_vlan_id")
1070
1110
 
@@ -1072,7 +1112,11 @@ class SddcInitialConfigurationInitialClusterConfigurationNetworkConfiguration(di
1072
1112
  @pulumi.getter(name="vsphereVlanId")
1073
1113
  def vsphere_vlan_id(self) -> Optional[str]:
1074
1114
  """
1075
- (Required) (Updatable) The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN to use for the vSphere component of the VMware environment. **Deprecated**. Please use `vsphere_vlan_id` of `network_configuration` instead.
1115
+ The [OCID](https://docs.cloud.oracle.com/iaas/Content/General/Concepts/identifiers.htm) of the VLAN used by the SDDC for the vSphere component of the VMware environment. This VLAN is a mandatory attribute for Management Cluster.
1116
+
1117
+ This attribute is not guaranteed to reflect the vSphere VLAN currently used by the ESXi hosts in the Cluster. The purpose of this attribute is to show the vSphere VLAN that the Oracle Cloud VMware Solution will use for any new ESXi hosts that you *add to this Cluster in the future* with [CreateEsxiHost](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/EsxiHost/CreateEsxiHost).
1118
+
1119
+ Therefore, if you change the existing ESXi hosts in the Cluster to use a different VLAN for the vSphere component of the VMware environment, you should use [UpdateCluster](https://docs.cloud.oracle.com/iaas/api/#/en/vmware/20200501/Sddc/UpdateSddc) to update the Cluster's `vsphereVlanId` with that new VLAN's OCID.
1076
1120
  """
1077
1121
  return pulumi.get(self, "vsphere_vlan_id")
1078
1122