optocalib-lab 0.1.0__py3-none-any.whl
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
optocalib/__init__.py
ADDED
optocalib/core.py
ADDED
|
@@ -0,0 +1,61 @@
|
|
|
1
|
+
import cv2
|
|
2
|
+
import numpy as np
|
|
3
|
+
|
|
4
|
+
def calibrate_image(bgr_img: np.ndarray, out_w: int = 820, out_h: int = 360, ref_box=(35, 85, 95, 275)):
|
|
5
|
+
h, w = bgr_img.shape[:2]
|
|
6
|
+
target_w = 600
|
|
7
|
+
scale = target_w / float(w) if w > target_w else 1.0
|
|
8
|
+
small = cv2.resize(bgr_img, (int(w * scale), int(h * scale)), interpolation=cv2.INTER_AREA) if scale < 1.0 else bgr_img
|
|
9
|
+
gray = cv2.cvtColor(small, cv2.COLOR_BGR2GRAY)
|
|
10
|
+
|
|
11
|
+
aruco_dict = cv2.aruco.getPredefinedDictionary(cv2.aruco.DICT_4X4_50)
|
|
12
|
+
params = cv2.aruco.DetectorParameters()
|
|
13
|
+
params.cornerRefinementMethod = cv2.aruco.CORNER_REFINE_NONE
|
|
14
|
+
detector = cv2.aruco.ArucoDetector(aruco_dict, params)
|
|
15
|
+
corners, ids, _ = detector.detectMarkers(gray)
|
|
16
|
+
|
|
17
|
+
locked = False
|
|
18
|
+
aligned = cv2.resize(bgr_img, (out_w, out_h))
|
|
19
|
+
|
|
20
|
+
if ids is not None and len(ids) >= 4:
|
|
21
|
+
centers = {}
|
|
22
|
+
for i, mid in enumerate(ids.flatten()):
|
|
23
|
+
if int(mid) in (0, 1, 2, 3):
|
|
24
|
+
pts = corners[i].reshape(4, 2) / scale
|
|
25
|
+
centers[int(mid)] = pts.mean(axis=0)
|
|
26
|
+
if all(k in centers for k in (0, 1, 2, 3)):
|
|
27
|
+
src_pts = np.array((centers[0], centers[1], centers[2], centers[3]), dtype=np.float32)
|
|
28
|
+
dst_pts = np.array(((0, 0), (out_w - 1, 0), (out_w - 1, out_h - 1), (0, out_h - 1)), dtype=np.float32)
|
|
29
|
+
matrix = cv2.getPerspectiveTransform(src_pts, dst_pts)
|
|
30
|
+
aligned = cv2.warpPerspective(bgr_img, matrix, (out_w, out_h))
|
|
31
|
+
locked = True
|
|
32
|
+
|
|
33
|
+
x1, y1, x2, y2 = ref_box
|
|
34
|
+
ref_patch = aligned[y1:y2, x1:x2].astype(np.float32)
|
|
35
|
+
mean_bgr = np.maximum(ref_patch.mean(axis=(0, 1)), 1.0)
|
|
36
|
+
gains = 240.0 / mean_bgr
|
|
37
|
+
calibrated = np.clip(aligned.astype(np.float32) * gains, 0, 255).astype(np.uint8)
|
|
38
|
+
|
|
39
|
+
lab_before = cv2.cvtColor(aligned[y1:y2, x1:x2], cv2.COLOR_BGR2LAB).astype(np.float32).mean(axis=(0, 1))
|
|
40
|
+
lab_after = cv2.cvtColor(calibrated[y1:y2, x1:x2], cv2.COLOR_BGR2LAB).astype(np.float32).mean(axis=(0, 1))
|
|
41
|
+
target_lab = np.array([240.0, 128.0, 128.0])
|
|
42
|
+
de_before = float(np.linalg.norm(lab_before - target_lab))
|
|
43
|
+
de_after = float(np.linalg.norm(lab_after - target_lab))
|
|
44
|
+
|
|
45
|
+
return {
|
|
46
|
+
"image": calibrated,
|
|
47
|
+
"aruco_locked": locked,
|
|
48
|
+
"delta_e_before": round(de_before, 2),
|
|
49
|
+
"delta_e_after": round(de_after, 2),
|
|
50
|
+
"gains_bgr": [round(float(g), 3) for g in gains]
|
|
51
|
+
}
|
|
52
|
+
|
|
53
|
+
def measure_roi_lab(calibrated_bgr: np.ndarray, box: tuple):
|
|
54
|
+
x1, y1, x2, y2 = box
|
|
55
|
+
roi = calibrated_bgr[y1:y2, x1:x2]
|
|
56
|
+
lab = cv2.cvtColor(roi, cv2.COLOR_BGR2LAB).astype(np.float32).mean(axis=(0, 1))
|
|
57
|
+
return {
|
|
58
|
+
"L": round(float(lab[0] * 100.0 / 255.0), 2),
|
|
59
|
+
"a": round(float(lab[1] - 128.0), 2),
|
|
60
|
+
"b": round(float(lab[2] - 128.0), 2),
|
|
61
|
+
}
|
optocalib/generator.py
ADDED
|
@@ -0,0 +1,17 @@
|
|
|
1
|
+
import cv2
|
|
2
|
+
import numpy as np
|
|
3
|
+
|
|
4
|
+
def generate_calibration_card(filename: str = "calibration_card.png", width: int = 820, height: int = 360):
|
|
5
|
+
"""Generates a printable calibration mat with 4 ArUco markers and a white reference strip."""
|
|
6
|
+
card = np.full((height, width, 3), 255, dtype=np.uint8)
|
|
7
|
+
cv2.rectangle(card, (25, 70), (105, height - 70), (245, 245, 245), -1)
|
|
8
|
+
cv2.rectangle(card, (25, 70), (105, height - 70), (200, 200, 200), 1)
|
|
9
|
+
|
|
10
|
+
aruco_dict = cv2.aruco.getPredefinedDictionary(cv2.aruco.DICT_4X4_50)
|
|
11
|
+
markers = ((0, 4, 4), (1, width - 54, 4), (2, width - 54, height - 54), (3, 4, height - 54))
|
|
12
|
+
for mid, mx, my in markers:
|
|
13
|
+
m_img = cv2.cvtColor(cv2.aruco.generateImageMarker(aruco_dict, mid, 50), cv2.COLOR_GRAY2BGR)
|
|
14
|
+
card[my:my+50, mx:mx+50] = m_img
|
|
15
|
+
|
|
16
|
+
cv2.imwrite(filename, card)
|
|
17
|
+
return filename
|
|
@@ -0,0 +1,38 @@
|
|
|
1
|
+
Metadata-Version: 2.4
|
|
2
|
+
Name: optocalib-lab
|
|
3
|
+
Version: 0.1.0
|
|
4
|
+
Summary: Lightweight ArUco-locked perspective alignment and Delta-E76 colorimetric calibration for scientific and industrial computer vision.
|
|
5
|
+
Project-URL: Homepage, https://github.com
|
|
6
|
+
Requires-Python: >=3.8
|
|
7
|
+
Description-Content-Type: text/markdown
|
|
8
|
+
Requires-Dist: numpy
|
|
9
|
+
Requires-Dist: opencv-contrib-python-headless
|
|
10
|
+
|
|
11
|
+
# OptoCalib
|
|
12
|
+
|
|
13
|
+
**Lightweight ArUco-locked perspective alignment and Δ E₇₆ colorimetric calibration for scientific and industrial computer vision.**
|
|
14
|
+
|
|
15
|
+
`optocalib` solves two major challenges in smartphone-based optical sensing (microfluidics, LAMP/PCR assays, water quality strips, agriculture leaf colorimetry, and industrial QC):
|
|
16
|
+
1. **Perspective & Scale Drift:** Automatically locks onto 4 printed ArUco markers (`IDs 0–3`) and rectifies skewed images in `<5 ms`.
|
|
17
|
+
2. **Ambient Lighting Bias:** Normalizes illumination using a built-in white reference patch and quantifies color accuracy via perceptual Δ E₇₆ and CIELAB (\(L^*, a^*, b^*\)).
|
|
18
|
+
|
|
19
|
+
## Quick Start
|
|
20
|
+
|
|
21
|
+
```python
|
|
22
|
+
import cv2
|
|
23
|
+
from optocalib import calibrate_image, measure_roi_lab, generate_calibration_card
|
|
24
|
+
|
|
25
|
+
# 1. Generate a printable calibration template
|
|
26
|
+
generate_calibration_card("my_lab_mat.png")
|
|
27
|
+
|
|
28
|
+
# 2. Calibrate a skewed/unevenly lit photo
|
|
29
|
+
img = cv2.imread("sample_photo.jpg")
|
|
30
|
+
result = calibrate_image(img)
|
|
31
|
+
|
|
32
|
+
print("Locked:", result["aruco_locked"])
|
|
33
|
+
print("Delta-E76 Improved:", result["delta_e_before"], "->", result["delta_e_after"])
|
|
34
|
+
|
|
35
|
+
# 3. Measure perceptual CIELAB color in any ROI
|
|
36
|
+
lab_values = measure_roi_lab(result["image"], box=(145, 145, 199, 295))
|
|
37
|
+
print("CIELAB:", lab_values)
|
|
38
|
+
```
|
|
@@ -0,0 +1,7 @@
|
|
|
1
|
+
optocalib/__init__.py,sha256=SPrc6RCkFCKQzaAVel-gI91BzepoVWSlBEY2i6E1src,201
|
|
2
|
+
optocalib/core.py,sha256=_WwigMnrs4sBT4Cs6N96AmV4fC0KGNln-Szhe9-qhfk,2736
|
|
3
|
+
optocalib/generator.py,sha256=JWWFgDGcuRiqZdNb4FMS1ZbETZRO7HARNEp9mNTOqH8,845
|
|
4
|
+
optocalib_lab-0.1.0.dist-info/METADATA,sha256=KHAXYZDbc8laJ1Q2Hynfh94ZvTf7UrqsEF4Dt2-rvZA,1628
|
|
5
|
+
optocalib_lab-0.1.0.dist-info/WHEEL,sha256=mOdXR9C3wMVov7cSY8PY-XCzo3SmmWCHvGQr5csJoao,91
|
|
6
|
+
optocalib_lab-0.1.0.dist-info/top_level.txt,sha256=_1hVCpT8M42NsF0vyUqfVWPA5owSVj2KQwmvUgucQgE,10
|
|
7
|
+
optocalib_lab-0.1.0.dist-info/RECORD,,
|
|
@@ -0,0 +1 @@
|
|
|
1
|
+
optocalib
|