oceanstream-echopype 0.11.1a3__py3-none-any.whl

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (102) hide show
  1. _echopype_version.py +1 -0
  2. echopype/__init__.py +33 -0
  3. echopype/calibrate/__init__.py +3 -0
  4. echopype/calibrate/api.py +424 -0
  5. echopype/calibrate/cal_params.py +522 -0
  6. echopype/calibrate/calibrate_azfp.py +117 -0
  7. echopype/calibrate/calibrate_base.py +128 -0
  8. echopype/calibrate/calibrate_ek.py +672 -0
  9. echopype/calibrate/ecs.py +475 -0
  10. echopype/calibrate/ek80_complex.py +414 -0
  11. echopype/calibrate/env_params.py +363 -0
  12. echopype/calibrate/env_params_old.py +205 -0
  13. echopype/calibrate/gpu_cal.py +204 -0
  14. echopype/calibrate/range.py +236 -0
  15. echopype/clean/__init__.py +17 -0
  16. echopype/clean/api.py +717 -0
  17. echopype/clean/gpu_noise_est.py +161 -0
  18. echopype/clean/noise_est.py +134 -0
  19. echopype/clean/transient_noise/transient_fielding.py +235 -0
  20. echopype/clean/transient_noise/transient_matecho.py +287 -0
  21. echopype/clean/utils.py +402 -0
  22. echopype/colormap/__init__.py +9 -0
  23. echopype/colormap/cm.py +83 -0
  24. echopype/commongrid/__init__.py +7 -0
  25. echopype/commongrid/api.py +527 -0
  26. echopype/commongrid/gpu_mvbs.py +172 -0
  27. echopype/commongrid/utils.py +697 -0
  28. echopype/consolidate/__init__.py +3 -0
  29. echopype/consolidate/api.py +540 -0
  30. echopype/consolidate/ek_depth_utils.py +112 -0
  31. echopype/consolidate/loc_utils.py +159 -0
  32. echopype/consolidate/split_beam_angle.py +277 -0
  33. echopype/convert/__init__.py +23 -0
  34. echopype/convert/ad2cp_fields.yaml +1307 -0
  35. echopype/convert/api.py +946 -0
  36. echopype/convert/from_ping_data.py +720 -0
  37. echopype/convert/parse_ad2cp.py +1856 -0
  38. echopype/convert/parse_azfp.py +582 -0
  39. echopype/convert/parse_azfp6.py +698 -0
  40. echopype/convert/parse_base.py +716 -0
  41. echopype/convert/parse_ek60.py +16 -0
  42. echopype/convert/parse_ek80.py +17 -0
  43. echopype/convert/set_groups_ad2cp.py +532 -0
  44. echopype/convert/set_groups_azfp.py +860 -0
  45. echopype/convert/set_groups_azfp6.py +746 -0
  46. echopype/convert/set_groups_base.py +531 -0
  47. echopype/convert/set_groups_ek60.py +779 -0
  48. echopype/convert/set_groups_ek80.py +1462 -0
  49. echopype/convert/utils/__init__.py +0 -0
  50. echopype/convert/utils/ek_date_conversion.py +163 -0
  51. echopype/convert/utils/ek_duplicates.py +44 -0
  52. echopype/convert/utils/ek_raw_io.py +679 -0
  53. echopype/convert/utils/ek_raw_parsers.py +1817 -0
  54. echopype/convert/utils/ek_swap.py +93 -0
  55. echopype/core.py +111 -0
  56. echopype/echodata/__init__.py +9 -0
  57. echopype/echodata/api.py +134 -0
  58. echopype/echodata/combine.py +976 -0
  59. echopype/echodata/convention/1.0.yml +160 -0
  60. echopype/echodata/convention/__init__.py +6 -0
  61. echopype/echodata/convention/conv.py +29 -0
  62. echopype/echodata/convention/utils.py +16 -0
  63. echopype/echodata/echodata.py +748 -0
  64. echopype/echodata/sensor_ep_version_mapping/ep_version_mapper.py +30 -0
  65. echopype/echodata/sensor_ep_version_mapping/v05x_to_v06x.py +1156 -0
  66. echopype/echodata/simrad.py +230 -0
  67. echopype/echodata/utils_platform.py +143 -0
  68. echopype/echodata/widgets/__init__.py +0 -0
  69. echopype/echodata/widgets/static/css/style.css +360 -0
  70. echopype/echodata/widgets/static/html/icons-svg-inline.html +15 -0
  71. echopype/echodata/widgets/templates/echodata.html.j2 +44 -0
  72. echopype/echodata/widgets/templates/style.html.j2 +1 -0
  73. echopype/echodata/widgets/utils.py +74 -0
  74. echopype/echodata/widgets/widgets.py +56 -0
  75. echopype/mask/__init__.py +3 -0
  76. echopype/mask/api.py +801 -0
  77. echopype/mask/freq_diff.py +148 -0
  78. echopype/mask/gpu_mask.py +173 -0
  79. echopype/mask/seafloor_detection/bottom_basic.py +100 -0
  80. echopype/mask/seafloor_detection/bottom_blackwell.py +173 -0
  81. echopype/mask/seafloor_detection/utils.py +64 -0
  82. echopype/mask/shoal_detection/shoal_echoview.py +144 -0
  83. echopype/mask/shoal_detection/shoal_weill.py +160 -0
  84. echopype/metrics/__init__.py +13 -0
  85. echopype/metrics/summary_statistics.py +151 -0
  86. echopype/qc/__init__.py +3 -0
  87. echopype/qc/api.py +267 -0
  88. echopype/utils/__init__.py +0 -0
  89. echopype/utils/align.py +61 -0
  90. echopype/utils/coding.py +303 -0
  91. echopype/utils/compute.py +53 -0
  92. echopype/utils/gpu.py +241 -0
  93. echopype/utils/io.py +508 -0
  94. echopype/utils/log.py +115 -0
  95. echopype/utils/misc.py +87 -0
  96. echopype/utils/prov.py +331 -0
  97. echopype/utils/uwa.py +189 -0
  98. oceanstream_echopype-0.11.1a3.dist-info/METADATA +216 -0
  99. oceanstream_echopype-0.11.1a3.dist-info/RECORD +102 -0
  100. oceanstream_echopype-0.11.1a3.dist-info/WHEEL +5 -0
  101. oceanstream_echopype-0.11.1a3.dist-info/licenses/LICENSE +201 -0
  102. oceanstream_echopype-0.11.1a3.dist-info/top_level.txt +2 -0
_echopype_version.py ADDED
@@ -0,0 +1 @@
1
+ version = "0.11.1a3" # noqa
echopype/__init__.py ADDED
@@ -0,0 +1,33 @@
1
+ from __future__ import absolute_import, division, print_function
2
+
3
+ from _echopype_version import version as __version__ # noqa
4
+
5
+ from . import calibrate, clean, commongrid, consolidate, mask, utils
6
+ from .convert.api import open_raw, open_raw_multi
7
+ from .convert.from_ping_data import PingAccumulator, from_ping_data
8
+ from .echodata.api import open_converted
9
+ from .echodata.combine import combine_echodata
10
+ from .utils.io import init_ep_dir
11
+ from .utils.log import verbose
12
+
13
+ # Turn off verbosity for echopype
14
+ verbose(override=True)
15
+
16
+ init_ep_dir()
17
+
18
+ __all__ = [
19
+ "calibrate",
20
+ "clean",
21
+ "combine_echodata",
22
+ "commongrid",
23
+ "consolidate",
24
+ "from_ping_data",
25
+ "mask",
26
+ "metrics",
27
+ "open_converted",
28
+ "open_raw",
29
+ "open_raw_multi",
30
+ "PingAccumulator",
31
+ "utils",
32
+ "verbose",
33
+ ]
@@ -0,0 +1,3 @@
1
+ from .api import compute_Sv, compute_TS
2
+
3
+ __all__ = ["compute_Sv", "compute_TS"]
@@ -0,0 +1,424 @@
1
+ import numpy as np
2
+ import xarray as xr
3
+
4
+ from ..echodata import EchoData
5
+ from ..echodata.simrad import check_input_args_combination
6
+ from ..utils.log import _init_logger
7
+ from ..utils.prov import echopype_prov_attrs, source_files_vars
8
+ from .calibrate_azfp import CalibrateAZFP
9
+ from .calibrate_ek import CalibrateEK60, CalibrateEK80
10
+
11
+ CALIBRATOR = {
12
+ "EK60": CalibrateEK60,
13
+ "EK80": CalibrateEK80,
14
+ "AZFP": CalibrateAZFP,
15
+ "ES70": CalibrateEK60,
16
+ "ES80": CalibrateEK80,
17
+ "EA640": CalibrateEK80,
18
+ }
19
+
20
+ logger = _init_logger(__name__)
21
+
22
+
23
+ def _to_vec(da, ch_idx, n_pings):
24
+ """Extract a 1-D ``(n_pings,)`` float64 vector from an xarray DataArray.
25
+
26
+ Handles DataArrays with or without a ``channel`` dimension and varying
27
+ dim order (e.g. ``transmit_power`` is ``(channel, ping_time)``).
28
+ """
29
+ if "channel" in da.dims:
30
+ v = da.isel(channel=ch_idx)
31
+ else:
32
+ v = da
33
+ val = np.atleast_1d(v.values.ravel()).astype(np.float64)
34
+ if val.size == 1:
35
+ val = np.full(n_pings, val[0])
36
+ return val
37
+
38
+
39
+ def _compute_sv_gpu_ek80(echodata, cal_obj):
40
+ """GPU-accelerated Sv for EK80 CW complex mode.
41
+
42
+ Uses the already-initialised *cal_obj* (``CalibrateEK80``) to read
43
+ calibration parameters, then computes Sv per channel on GPU via
44
+ :func:`~echopype.calibrate.gpu_cal.compute_sv_from_complex_gpu`.
45
+
46
+ Returns an ``xr.Dataset`` with the same structure as the standard path.
47
+ """
48
+ from .ek80_complex import get_filter_coeff, get_tau_effective, get_transmit_signal
49
+ from .gpu_cal import compute_sv_from_complex_gpu
50
+ from .range import range_mod_TVG_EK
51
+
52
+ beam = echodata[cal_obj.ed_beam_group].sel(channel=cal_obj.chan_sel)
53
+ vend = echodata["Vendor_specific"].sel(channel=cal_obj.chan_sel)
54
+
55
+ # Calibration scalars
56
+ z_et = float(cal_obj.cal_params["impedance_transducer"].values.flat[0])
57
+ z_er = float(cal_obj.cal_params["impedance_transceiver"].values.flat[0])
58
+ n_beams = int(beam["beam"].size)
59
+
60
+ sound_speed_da = cal_obj.env_params["sound_speed"]
61
+ absorption_da = cal_obj.env_params["sound_absorption"]
62
+ range_meter = cal_obj.range_meter
63
+ tvg_mod = range_mod_TVG_EK(echodata, cal_obj.ed_beam_group, range_meter, sound_speed_da)
64
+
65
+ # Effective pulse length
66
+ tx_coeff = get_filter_coeff(vend)
67
+ fs = cal_obj.cal_params["receiver_sampling_frequency"]
68
+ tx, tx_time = get_transmit_signal(beam, tx_coeff, "CW", fs)
69
+ tau_eff = get_tau_effective(
70
+ ytx_dict=tx,
71
+ fs_deci_dict={k: 1 / np.diff(v[:2]) for (k, v) in tx_time.items()},
72
+ waveform_mode="CW",
73
+ channel=cal_obj.chan_sel,
74
+ ping_time=beam["ping_time"],
75
+ )
76
+ ch_GPT = (vend["transceiver_type"] == "GPT").compute()
77
+ tau_eff[ch_GPT] = beam["transmit_duration_nominal"][ch_GPT].isel(ping_time=0)
78
+
79
+ # Per-channel GPU Sv
80
+ n_channels = beam.sizes["channel"]
81
+ n_pings = beam.sizes["ping_time"]
82
+ n_range = beam.sizes["range_sample"]
83
+ sv_all = np.empty((n_channels, n_pings, n_range), dtype=np.float64)
84
+
85
+ for ch in range(n_channels):
86
+ sv_all[ch] = compute_sv_from_complex_gpu(
87
+ beam["backscatter_r"].isel(channel=ch).values,
88
+ beam["backscatter_i"].isel(channel=ch).values,
89
+ tvg_mod.isel(channel=ch).values,
90
+ _to_vec(sound_speed_da, ch, n_pings),
91
+ _to_vec(absorption_da, ch, n_pings),
92
+ _to_vec(cal_obj.freq_center, ch, n_pings),
93
+ _to_vec(beam["transmit_power"], ch, n_pings),
94
+ _to_vec(cal_obj.cal_params["gain_correction"], ch, n_pings),
95
+ _to_vec(cal_obj.cal_params["equivalent_beam_angle"], ch, n_pings),
96
+ _to_vec(cal_obj.cal_params["sa_correction"], ch, n_pings),
97
+ _to_vec(tau_eff, ch, n_pings),
98
+ z_et, z_er, n_beams,
99
+ )
100
+
101
+ # Assemble output Dataset matching the standard calibration format
102
+ sv_da = xr.DataArray(
103
+ sv_all,
104
+ dims=["channel", "ping_time", "range_sample"],
105
+ coords={
106
+ "channel": beam["channel"],
107
+ "ping_time": beam["ping_time"],
108
+ "range_sample": beam["range_sample"],
109
+ },
110
+ name="Sv",
111
+ )
112
+ ds = sv_da.to_dataset()
113
+ ds = ds.merge(range_meter)
114
+ ds["frequency_nominal"] = beam["frequency_nominal"]
115
+ ds = cal_obj._add_params_to_output(ds)
116
+
117
+ return ds
118
+
119
+
120
+ def _compute_cal(
121
+ cal_type,
122
+ echodata: EchoData,
123
+ env_params=None,
124
+ cal_params=None,
125
+ ecs_file=None,
126
+ waveform_mode=None,
127
+ encode_mode=None,
128
+ use_gpu="auto",
129
+ ):
130
+ # Make waveform_mode "FM" equivalent to "BB"
131
+ waveform_mode = "BB" if waveform_mode == "FM" else waveform_mode
132
+
133
+ # Check on waveform_mode and encode_mode inputs
134
+ if echodata.sonar_model == "EK80":
135
+ if waveform_mode is None or encode_mode is None:
136
+ raise ValueError("waveform_mode and encode_mode must be specified for EK80 calibration")
137
+ check_input_args_combination(waveform_mode=waveform_mode, encode_mode=encode_mode)
138
+ elif echodata.sonar_model in ("EK60", "AZFP"):
139
+ if waveform_mode is not None and waveform_mode != "CW":
140
+ logger.warning(
141
+ "This sonar model transmits only narrowband signals (waveform_mode='CW'). "
142
+ "Calibration will be in CW mode",
143
+ )
144
+ if encode_mode is not None and encode_mode != "power":
145
+ logger.warning(
146
+ "This sonar model only record data as power or power/angle samples "
147
+ "(encode_mode='power'). Calibration will be done on the power samples.",
148
+ )
149
+
150
+ # Set up calibration object
151
+ cal_obj = CALIBRATOR[echodata.sonar_model](
152
+ echodata,
153
+ env_params=env_params,
154
+ cal_params=cal_params,
155
+ ecs_file=ecs_file,
156
+ waveform_mode=waveform_mode,
157
+ encode_mode=encode_mode,
158
+ )
159
+
160
+ # Check Echodata Backscatter Size
161
+ cal_obj._check_echodata_backscatter_size()
162
+
163
+ # Perform calibration — optionally via GPU
164
+ from ..utils.gpu import resolve_use_gpu
165
+
166
+ _do_gpu = resolve_use_gpu(use_gpu)
167
+ if (
168
+ _do_gpu
169
+ and cal_type == "Sv"
170
+ and echodata.sonar_model in ("EK80", "ES80", "EA640")
171
+ and waveform_mode == "CW"
172
+ and encode_mode == "complex"
173
+ ):
174
+ cal_ds = _compute_sv_gpu_ek80(echodata, cal_obj)
175
+ logger.info("compute_Sv: used GPU path (EK80 CW complex)")
176
+ elif cal_type == "Sv":
177
+ cal_ds = cal_obj.compute_Sv()
178
+ elif cal_type == "TS":
179
+ cal_ds = cal_obj.compute_TS()
180
+ else:
181
+ raise ValueError("cal_type must be Sv or TS")
182
+
183
+ # Add attributes
184
+ def add_attrs(cal_type, ds):
185
+ """Add attributes to backscattering strength dataset.
186
+ cal_type: Sv or TS
187
+ """
188
+ ds["range_sample"].attrs = {"long_name": "Along-range sample number, base 0"}
189
+ ds["echo_range"].attrs = {"long_name": "Range distance", "units": "m"}
190
+ ds[cal_type].attrs = {
191
+ "long_name": {
192
+ "Sv": "Volume backscattering strength (Sv re 1 m-1)",
193
+ "TS": "Target strength (TS re 1 m^2)",
194
+ }[cal_type],
195
+ "units": "dB",
196
+ }
197
+ if echodata.sonar_model == "EK80":
198
+ ds[cal_type] = ds[cal_type].assign_attrs(
199
+ {
200
+ "waveform_mode": waveform_mode,
201
+ "encode_mode": encode_mode,
202
+ }
203
+ )
204
+
205
+ add_attrs(cal_type, cal_ds)
206
+
207
+ # Add provinance
208
+ # Provenance source files may originate from raw files (echodata.source_files)
209
+ # or converted files (echodata.converted_raw_path)
210
+ if echodata.source_file is not None:
211
+ source_file = echodata.source_file
212
+ elif echodata.converted_raw_path is not None:
213
+ source_file = echodata.converted_raw_path
214
+ else:
215
+ source_file = "SOURCE FILE NOT IDENTIFIED"
216
+
217
+ prov_dict = echopype_prov_attrs(process_type="processing")
218
+ prov_dict["processing_function"] = f"calibrate.compute_{cal_type}"
219
+ files_vars = source_files_vars(source_file)
220
+ cal_ds = (
221
+ cal_ds.assign(**files_vars["source_files_var"])
222
+ .assign_coords(**files_vars["source_files_coord"])
223
+ .assign_attrs(prov_dict)
224
+ )
225
+
226
+ # Add water_level to the created xr.Dataset
227
+ if "water_level" in echodata["Platform"].data_vars.keys():
228
+ cal_ds["water_level"] = echodata["Platform"].water_level
229
+
230
+ return cal_ds
231
+
232
+
233
+ def compute_Sv(echodata: EchoData, use_gpu="auto", **kwargs) -> xr.Dataset:
234
+ """
235
+ Compute volume backscattering strength (Sv) from raw data.
236
+
237
+ The calibration routine varies depending on the sonar type.
238
+ Currently this operation is supported for the following ``sonar_model``:
239
+ EK60, AZFP, EK80 (see Notes below for detail).
240
+
241
+ Parameters
242
+ ----------
243
+ echodata : EchoData
244
+ An `EchoData` object created by using `open_raw` or `open_converted`
245
+
246
+ use_gpu : bool or {"auto"}, default "auto"
247
+ GPU acceleration strategy:
248
+
249
+ * ``"auto"`` — use GPU when CuPy + CUDA are available (transparent).
250
+ * ``True`` — require GPU; raises ``RuntimeError`` if unavailable.
251
+ * ``False`` — force CPU-only computation.
252
+
253
+ Currently GPU-accelerated for EK80/ES80/EA640 with
254
+ ``waveform_mode="CW"`` and ``encode_mode="complex"``.
255
+
256
+ env_params : dict, optional
257
+ Environmental parameters needed for calibration.
258
+ Users can supply `"sound speed"` and `"absorption"` directly,
259
+ or specify other variables that can be used to compute them,
260
+ including `"temperature"`, `"salinity"`, and `"pressure"`.
261
+
262
+ For EK60 and EK80 echosounders, by default echopype uses
263
+ environmental variables stored in the data files.
264
+ For AZFP echosounder, all environmental parameters need to be supplied.
265
+ AZFP echosounders typically are equipped with an internal temperature
266
+ sensor, and some are equipped with a pressure sensor, but automatically
267
+ using these pressure data is not currently supported.
268
+
269
+ cal_params : dict, optional
270
+ Intrument-dependent calibration parameters.
271
+
272
+ For EK60, EK80, and AZFP echosounders, by default echopype uses
273
+ environmental variables stored in the data files.
274
+ Users can optionally pass in custom values shown below.
275
+
276
+ - for EK60 echosounder, allowed parameters include:
277
+ `"sa_correction"`, `"gain_correction"`, `"equivalent_beam_angle"`
278
+ - for AZFP echosounder, allowed parameters include:
279
+ `"EL"`, `"DS"`, `"TVR"`, `"VTX0"`, `"equivalent_beam_angle"`, `"Sv_offset"`
280
+
281
+ Passing in calibration parameters for other echosounders
282
+ are not currently supported.
283
+
284
+ waveform_mode : {"CW", "BB", "FM"}, optional
285
+ Type of transmit waveform.
286
+ Required only for data from the EK80 echosounder
287
+ and not used with any other echosounder.
288
+
289
+ - `"CW"` for narrowband transmission,
290
+ returned echoes recorded either as complex or power/angle samples
291
+ - `"BB"` or `"FM"` for broadband transmission,
292
+ returned echoes recorded as complex samples
293
+
294
+ encode_mode : {"complex", "power"}, optional
295
+ Type of encoded return echo data.
296
+ Required only for data from the EK80 echosounder
297
+ and not used with any other echosounder.
298
+
299
+ - `"complex"` for complex samples
300
+ - `"power"` for power/angle samples, only allowed when
301
+ the echosounder is configured for narrowband transmission
302
+
303
+ Returns
304
+ -------
305
+ xr.Dataset
306
+ The calibrated Sv dataset, including calibration parameters
307
+ and environmental variables used in the calibration operations.
308
+
309
+ Notes
310
+ -----
311
+ The EK80 echosounder can be configured to transmit
312
+ either broadband/frequency modulated (``waveform_mode="BB"`` or ``waveform_mode="FM"``)
313
+ or narrowband (``waveform_mode="CW"``) signals.
314
+ When transmitting in broadband mode, the returned echoes are
315
+ encoded as complex samples (``encode_mode="complex"``).
316
+ When transmitting in narrowband mode, the returned echoes can be encoded
317
+ either as complex samples (``encode_mode="complex"``)
318
+ or as power/angle combinations (``encode_mode="power"``) in a format
319
+ similar to those recorded by EK60 echosounders.
320
+
321
+ The current calibration implemented for EK80 broadband complex data
322
+ uses band-integrated Sv with the gain computed at the center frequency
323
+ of the transmit signal.
324
+
325
+ The returned xr.Dataset will contain the variable `water_level` from the
326
+ EchoData object provided, if it exists. If `water_level` is not returned,
327
+ it must be set using `EchoData.update_platform()`.
328
+ """
329
+ return _compute_cal(cal_type="Sv", echodata=echodata, use_gpu=use_gpu, **kwargs)
330
+
331
+
332
+ def compute_TS(echodata: EchoData, **kwargs):
333
+ """
334
+ Compute target strength (TS) from raw data.
335
+
336
+ The calibration routine varies depending on the sonar type.
337
+ Currently this operation is supported for the following ``sonar_model``:
338
+ EK60, AZFP, EK80 (see Notes below for detail).
339
+
340
+ Parameters
341
+ ----------
342
+ echodata : EchoData
343
+ An `EchoData` object created by using `open_raw` or `open_converted`
344
+
345
+ env_params : dict, optional
346
+ Environmental parameters needed for calibration.
347
+ Users can supply `"sound speed"` and `"absorption"` directly,
348
+ or specify other variables that can be used to compute them,
349
+ including `"temperature"`, `"salinity"`, and `"pressure"`.
350
+
351
+ For EK60 and EK80 echosounders, by default echopype uses
352
+ environmental variables stored in the data files.
353
+ For AZFP echosounder, all environmental parameters need to be supplied.
354
+ AZFP echosounders typically are equipped with an internal temperature
355
+ sensor, and some are equipped with a pressure sensor, but automatically
356
+ using these pressure data is not currently supported.
357
+
358
+ cal_params : dict, optional
359
+ Intrument-dependent calibration parameters.
360
+
361
+ For EK60, EK80, and AZFP echosounders, by default echopype uses
362
+ environmental variables stored in the data files.
363
+ Users can optionally pass in custom values shown below.
364
+
365
+ - for EK60 echosounder, allowed parameters include:
366
+ `"sa_correction"`, `"gain_correction"`, `"equivalent_beam_angle"`
367
+ - for AZFP echosounder, allowed parameters include:
368
+ `"EL"`, `"DS"`, `"TVR"`, `"VTX0"`, `"equivalent_beam_angle"`, `"Sv_offset"`
369
+
370
+ Passing in calibration parameters for other echosounders
371
+ are not currently supported.
372
+
373
+ waveform_mode : {"CW", "BB", "FM"}, optional
374
+ Type of transmit waveform.
375
+ Required only for data from the EK80 echosounder
376
+ and not used with any other echosounder.
377
+
378
+ - `"CW"` for narrowband transmission,
379
+ returned echoes recorded either as complex or power/angle samples
380
+ - `"BB"` or `"FM"` for broadband transmission,
381
+ returned echoes recorded as complex samples
382
+
383
+ encode_mode : {"complex", "power"}, optional
384
+ Type of encoded return echo data.
385
+ Required only for data from the EK80 echosounder
386
+ and not used with any other echosounder.
387
+
388
+ - `"complex"` for complex samples
389
+ - `"power"` for power/angle samples, only allowed when
390
+ the echosounder is configured for narrowband transmission
391
+
392
+ Returns
393
+ -------
394
+ xr.Dataset
395
+ The calibrated TS dataset, including calibration parameters
396
+ and environmental variables used in the calibration operations.
397
+
398
+ Notes
399
+ -----
400
+ The EK80 echosounder can be configured to transmit
401
+ either broadband/frequency modulated (``waveform_mode="BB"`` or ``waveform_mode="FM"``)
402
+ or narrowband (``waveform_mode="CW"``) signals.
403
+ When transmitting in broadband mode, the returned echoes are
404
+ encoded as complex samples (``encode_mode="complex"``).
405
+ When transmitting in narrowband mode, the returned echoes can be encoded
406
+ either as complex samples (``encode_mode="complex"``)
407
+ or as power/angle combinations (``encode_mode="power"``) in a format
408
+ similar to those recorded by EK60 echosounders.
409
+
410
+ The current calibration implemented for EK80 broadband complex data
411
+ uses band-integrated TS with the gain computed at the center frequency
412
+ of the transmit signal.
413
+
414
+ Note that in the fisheries acoustics context, it is customary to
415
+ associate TS to a single scatterer.
416
+ TS is defined as: TS = 10 * np.log10 (sigma_bs), where sigma_bs
417
+ is the backscattering cross-section.
418
+
419
+ For details, see:
420
+ MacLennan et al. 2002. A consistent approach to definitions and
421
+ symbols in fisheries acoustics. ICES J. Mar. Sci. 59: 365-369.
422
+ https://doi.org/10.1006/jmsc.2001.1158
423
+ """
424
+ return _compute_cal(cal_type="TS", echodata=echodata, **kwargs)