nisync 0.1__py3-none-any.whl

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
nisync/__init__.py ADDED
@@ -0,0 +1,6 @@
1
+ """NI-Sync Python API."""
2
+
3
+ from nisync import constants # noqa: F401
4
+ from nisync import enums # noqa: F401
5
+ from nisync import errors # noqa: F401
6
+ from nisync.session import Session # noqa: F401
nisync/_attributes.py ADDED
@@ -0,0 +1,35 @@
1
+ class Attribute(object):
2
+ def __init__(self, attribute_id):
3
+ self._attribute_id = attribute_id
4
+
5
+
6
+ class AttributeViInt32(Attribute):
7
+ def __get__(self, session, session_type):
8
+ return session._get_attribute_vi_int32(self._attribute_id)
9
+
10
+ def __set__(self, session, value):
11
+ session._set_attribute_vi_int32(self._attribute_id, value)
12
+
13
+
14
+ class AttributeViReal64(Attribute):
15
+ def __get__(self, session, session_type):
16
+ return session._get_attribute_vi_real64(self._attribute_id)
17
+
18
+ def __set__(self, session, value):
19
+ session._set_attribute_vi_real64(self._attribute_id, value)
20
+
21
+
22
+ class AttributeViBoolean(Attribute):
23
+ def __get__(self, session, session_type):
24
+ return session._get_attribute_vi_boolean(self._attribute_id)
25
+
26
+ def __set__(self, session, value):
27
+ session._set_attribute_vi_boolean(self._attribute_id, value)
28
+
29
+
30
+ class AttributeViString(Attribute):
31
+ def __get__(self, session, session_type):
32
+ return session._get_attribute_vi_string(self._attribute_id)
33
+
34
+ def __set__(self, session, value):
35
+ session._set_attribute_vi_string(self._attribute_id, value)
nisync/_errorcodes.py ADDED
@@ -0,0 +1,636 @@
1
+ # This file was generated
2
+
3
+ from nisync.enums import CtypesEnum
4
+
5
+
6
+ class Status(CtypesEnum):
7
+
8
+ #: This device is not properly calibrated.
9
+ #:
10
+ #: #define NISYNC_ERROR_CAL_UNCALIBRATED = NISYNC_WARN_BASE + 60
11
+ #:
12
+ #: nisyncerr_calUncalibrated = 1073365052
13
+ UNCALIBRATED = 1073365052
14
+
15
+ #: The request has been accepted by the remote device but processing has not been completed. Wait and attempt to query the property again.
16
+ #:
17
+ #: #define NISYNC_ERROR_NETWORK_CLIENT_IN_PROGRESS = NISYNC_WARN_BASE + 100
18
+ #:
19
+ #: nisyncerr_networkClientInProgress = 1073365092
20
+ NETWORK_CLIENT_IN_PROGRESS = 1073365092
21
+
22
+ #: The status code passed to the operation could not be interpreted.
23
+ #:
24
+ #: #define NISYNC_ERROR_UNKNOWN_STATUS = VI_WARN_UNKNOWN_STATUS
25
+ #:
26
+ #: nisyncerr_unknownStatus = 1073676421
27
+ UNKNOWN_STATUS = 1073676421
28
+
29
+ #: The specified instrument descriptor is invalid.
30
+ #:
31
+ #: #define NISYNC_ERROR_INVALID_DESCRIPTOR = NISYNC_ERROR_BASE + 1
32
+ #:
33
+ #: nisyncerr_invalidDescriptor = -1074118655
34
+ DESCRIPTOR_INVALID = -1074118655
35
+
36
+ #: The mode for this operation is invalid.
37
+ #:
38
+ #: #define NISYNC_ERROR_INVALID_MODE = NISYNC_ERROR_BASE + 2
39
+ #:
40
+ #: nisyncerr_invalidMode = -1074118654
41
+ MODE_INVALID = -1074118654
42
+
43
+ #: This operation requires a feature that is not supported.
44
+ #:
45
+ #: #define NISYNC_ERROR_FEATURE_NOT_SUPPORTED = NISYNC_ERROR_BASE + 3
46
+ #:
47
+ #: nisyncerr_featureNotSupported = -1074118653
48
+ FEATURE_NOT_SUPPORTED = -1074118653
49
+
50
+ #: There is a version mismatch.
51
+ #:
52
+ #: #define NISYNC_ERROR_VERSION_MISMATCH = NISYNC_ERROR_BASE + 4
53
+ #:
54
+ #: nisyncerr_versionMismatch = -1074118652
55
+ VERSION_MISMATCH = -1074118652
56
+
57
+ #: An internal software error occurred.
58
+ #:
59
+ #: #define NISYNC_ERROR_INTERNAL_SOFTWARE = NISYNC_ERROR_BASE + 5
60
+ #:
61
+ #: nisyncerr_internalSoftware = -1074118651
62
+ INTERNAL_SOFTWARE = -1074118651
63
+
64
+ #: An error occurred while reading or writing a file.
65
+ #:
66
+ #: #define NISYNC_ERROR_FILE_IO = NISYNC_ERROR_BASE + 6
67
+ #:
68
+ #: nisyncerr_fileIo = -1074118650
69
+ FILE_IO = -1074118650
70
+
71
+ #: This device does not support Reset.
72
+ #:
73
+ #: #define NISYNC_ERROR_RESET_NOT_SUPPORTED = NISYNC_ERROR_BASE + 7
74
+ #:
75
+ #: nisyncerr_resetNotSupported = -1074118649
76
+ RESET_NOT_SUPPORTED = -1074118649
77
+
78
+ #: A parameter for this operation is of an invalid type.
79
+ #:
80
+ #: #define NISYNC_ERROR_INVALID_TYPE = NISYNC_ERROR_BASE + 8
81
+ #:
82
+ #: nisyncerr_invalidType = -1074118648
83
+ TYPE_INVALID = -1074118648
84
+
85
+ #: The NI-Sync API Support is unable to communicate with the NI-Sync Runtime. To resolve this issue, install NI-Sync 18.0 or later.
86
+ #:
87
+ #: #define NISYNC_ERROR_API_SUPPORT_INCOMPATIBLE_WITH_RUNTIME = NISYNC_ERROR_BASE + 9
88
+ #:
89
+ #: nisyncerr_apiSupportIncompatibleWithRuntime = -1074118647
90
+ API_SUPPORT_INCOMPATIBLE_WITH_RUNTIME = -1074118647
91
+
92
+ #: An error occurred while initializing the driver.
93
+ #:
94
+ #: #define NISYNC_ERROR_DRIVER_INITIALIZATION = NISYNC_ERROR_BASE + 10
95
+ #:
96
+ #: nisyncerr_driverInitialization = -1074118646
97
+ DRIVER_INITIALIZATION = -1074118646
98
+
99
+ #: The driver timed out while performing an operation.
100
+ #:
101
+ #: #define NISYNC_ERROR_DRIVER_TIMEOUT = NISYNC_ERROR_BASE + 11
102
+ #:
103
+ #: nisyncerr_driverTimeout = -1074118645
104
+ DRIVER_TIMEOUT = -1074118645
105
+
106
+ #: A failure occurred while reading from the device.
107
+ #:
108
+ #: #define NISYNC_ERROR_READ_FAILURE = NISYNC_ERROR_BASE + 20
109
+ #:
110
+ #: nisyncerr_readFailure = -1074118636
111
+ READ_FAILED = -1074118636
112
+
113
+ #: A failure occurred while writing to the device.
114
+ #:
115
+ #: #define NISYNC_ERROR_WRITE_FAILURE = NISYNC_ERROR_BASE + 21
116
+ #:
117
+ #: nisyncerr_writeFailure = -1074118635
118
+ WRITE_FAILED = -1074118635
119
+
120
+ #: The specified device was not found.
121
+ #:
122
+ #: #define NISYNC_ERROR_DEVICE_NOT_FOUND = NISYNC_ERROR_BASE + 22
123
+ #:
124
+ #: nisyncerr_deviceNotFound = -1074118634
125
+ DEVICE_NOT_FOUND = -1074118634
126
+
127
+ #: The specified device is not ready.
128
+ #:
129
+ #: #define NISYNC_ERROR_DEVICE_NOT_READY = NISYNC_ERROR_BASE + 23
130
+ #:
131
+ #: nisyncerr_deviceNotReady = -1074118633
132
+ DEVICE_NOT_READY = -1074118633
133
+
134
+ #: An internal hardware error occurred.
135
+ #:
136
+ #: #define NISYNC_ERROR_INTERNAL_HARDWARE = NISYNC_ERROR_BASE + 24
137
+ #:
138
+ #: nisyncerr_internalHardware = -1074118632
139
+ INTERNAL_HARDWARE = -1074118632
140
+
141
+ #: An overflow condition occurred.
142
+ #:
143
+ #: #define NISYNC_ERROR_OVERFLOW = NISYNC_ERROR_BASE + 25
144
+ #:
145
+ #: nisyncerr_overflow = -1074118631
146
+ OVERFLOW = -1074118631
147
+
148
+ #: The specified device is a remote device. Remote devices are not allowed.
149
+ #:
150
+ #: #define NISYNC_ERROR_REMOTE_DEVICE = NISYNC_ERROR_BASE + 26
151
+ #:
152
+ #: nisyncerr_remoteDevice = -1074118630
153
+ REMOTE_DEVICE = -1074118630
154
+
155
+ #: The firmware failed to load.
156
+ #:
157
+ #: #define NISYNC_ERROR_FIRMWARE_LOAD = NISYNC_ERROR_BASE + 30
158
+ #:
159
+ #: nisyncerr_firmwareLoad = -1074118626
160
+ FIRMWARE_LOAD = -1074118626
161
+
162
+ #: The device is not initialized.
163
+ #:
164
+ #: #define NISYNC_ERROR_DEVICE_NOT_INITIALIZED = NISYNC_ERROR_BASE + 31
165
+ #:
166
+ #: nisyncerr_deviceNotInitialized = -1074118625
167
+ DEVICE_NOT_INITIALIZED = -1074118625
168
+
169
+ #: PXI_Clk10 is not present.
170
+ #:
171
+ #: #define NISYNC_ERROR_CLK10_NOT_PRESENT = NISYNC_ERROR_BASE + 32
172
+ #:
173
+ #: nisyncerr_clk10NotPresent = -1074118624
174
+ CLK10_NOT_PRESENT = -1074118624
175
+
176
+ #: This device does not support a PLL.
177
+ #:
178
+ #: #define NISYNC_ERROR_PLL_NOT_PRESENT = NISYNC_ERROR_BASE + 40
179
+ #:
180
+ #: nisyncerr_pllNotPresent = -1074118616
181
+ PLL_NOT_PRESENT = -1074118616
182
+
183
+ #: The device does not support a DDS.
184
+ #:
185
+ #: #define NISYNC_ERROR_DDS_NOT_PRESENT = NISYNC_ERROR_BASE + 41
186
+ #:
187
+ #: nisyncerr_ddsNotPresent = -1074118615
188
+ DDS_NOT_PRESENT = -1074118615
189
+
190
+ #: The specified attribute cannot be set because the DDS is already running.
191
+ #:
192
+ #: #define NISYNC_ERROR_DDS_ALREADY_STARTED = NISYNC_ERROR_BASE + 42
193
+ #:
194
+ #: nisyncerr_ddsAlreadyStarted = -1074118614
195
+ DDS_ALREADY_STARTED = -1074118614
196
+
197
+ #: The current DDS frequency is incompatible as a synchronization clock, either the DDS is off or running too fast.
198
+ #:
199
+ #: #define NISYNC_ERROR_DDS_SYNC_CLK_COMBO_INVALID = NISYNC_ERROR_BASE + 43
200
+ #:
201
+ #: nisyncerr_ddsSyncClkComboInvalid = -1074118613
202
+ DDS_SYNC_CLOCK_COMBO_INVALID = -1074118613
203
+
204
+ #: The specified source terminal is invalid for this operation.
205
+ #:
206
+ #: #define NISYNC_ERROR_SRC_TERMINAL_INVALID = NISYNC_ERROR_BASE + 50
207
+ #:
208
+ #: nisyncerr_srcTerminalInvalid = -1074118606
209
+ SOURCE_TERMINAL_INVALID = -1074118606
210
+
211
+ #: The specified destination terminal is invalid for this operation.
212
+ #:
213
+ #: #define NISYNC_ERROR_DEST_TERMINAL_INVALID = NISYNC_ERROR_BASE + 51
214
+ #:
215
+ #: nisyncerr_destTerminalInvalid = -1074118605
216
+ DESTINATION_TERMINAL_INVALID = -1074118605
217
+
218
+ #: The specified terminal is not connected.
219
+ #:
220
+ #: #define NISYNC_ERROR_TERMINAL_NOT_CONNECTED = NISYNC_ERROR_BASE + 52
221
+ #:
222
+ #: nisyncerr_terminalNotConnected = -1074118604
223
+ TERMINAL_NOT_CONNECTED = -1074118604
224
+
225
+ #: The specified synchronization clock is invalid for this operation.
226
+ #:
227
+ #: #define NISYNC_ERROR_SYNC_CLK_INVALID = NISYNC_ERROR_BASE + 53
228
+ #:
229
+ #: nisyncerr_syncClkInvalid = -1074118603
230
+ SYNC_CLOCK_INVALID = -1074118603
231
+
232
+ #: Terminal for the device is invalid.
233
+ #:
234
+ #: #define NISYNC_ERROR_TERMINAL_INVALID = NISYNC_ERROR_BASE + 54
235
+ #:
236
+ #: nisyncerr_terminalInvalid = -1074118602
237
+ TERMINAL_INVALID = -1074118602
238
+
239
+ #: Route failed because the PXI chassis is not identified. The existence of the source terminal depends on the chassis being identified. Use the Measurements & Automation Explorer (MAX) to identify your chassis.
240
+ #:
241
+ #: #define NISYNC_ERROR_SRC_TERMINAL_PXI_CHASSIS_NOT_IDENTIFIED = NISYNC_ERROR_BASE + 55
242
+ #:
243
+ #: nisyncerr_srcTerminalPxiChassisNotIdentified = -1074118601
244
+ SOURCE_TERMINAL_PXI_CHASSIS_NOT_IDENTIFIED = -1074118601
245
+
246
+ #: Route failed because the PXI chassis is not identified. The existence of the destination terminal depends on the chassis being identified. Use the Measurements & Automation Explorer (MAX) to identify your chassis.
247
+ #:
248
+ #: #define NISYNC_ERROR_DEST_TERMINAL_PXI_CHASSIS_NOT_IDENTIFIED = NISYNC_ERROR_BASE + 56
249
+ #:
250
+ #: nisyncerr_destTerminalPxiChassisNotIdentified = -1074118600
251
+ DESTINATION_TERMINAL_PXI_CHASSIS_NOT_IDENTIFIED = -1074118600
252
+
253
+ #: PXI_Star<n> is available as a source terminal only for devices in a system timing slot. To use PXI_Star<n>, move your device to a system timing slot.
254
+ #:
255
+ #: #define NISYNC_ERROR_SRC_TERMINAL_PXI_STARX_NOT_IN_SYS_TIMING_SLOT = NISYNC_ERROR_BASE + 57
256
+ #:
257
+ #: nisyncerr_srcTerminalPxiStarxNotInSysTimingSlot = -1074118599
258
+ SOURCE_TERMINAL_PXI_STARX_NOT_IN_SYS_TIMING_SLOT = -1074118599
259
+
260
+ #: PXI_Star<n> is available as a destination terminal only for devices in a system timing slot. To use PXI_Star<n>, move your device to a system timing slot.
261
+ #:
262
+ #: #define NISYNC_ERROR_DEST_TERMINAL_PXI_STARX_NOT_IN_SYS_TIMING_SLOT = NISYNC_ERROR_BASE + 58
263
+ #:
264
+ #: nisyncerr_destTerminalPxiStarxNotInSysTimingSlot = -1074118598
265
+ DESTINATION_TERMINAL_PXI_STARX_NOT_IN_SYS_TIMING_SLOT = -1074118598
266
+
267
+ #: PXI_Clk10_In is available as a destination terminal only for devices in a system timing slot. Move your device to a system timing slot.
268
+ #:
269
+ #: #define NISYNC_ERROR_DEST_TERMINAL_PXI_CLK10_IN_NOT_IN_SYS_TIMING_SLOT = NISYNC_ERROR_BASE + 59
270
+ #:
271
+ #: nisyncerr_destTerminalPxiClk10InNotInSysTimingSlot = -1074118597
272
+ DESTINATION_TERMINAL_PXI_CLK10_IN_NOT_IN_SYS_TIMING_SLOT = -1074118597
273
+
274
+ #: The supplied external calibration password is incorrect.
275
+ #:
276
+ #: #define NISYNC_ERROR_CAL_INCORRECT_PASSWORD = NISYNC_ERROR_BASE + 60
277
+ #:
278
+ #: nisyncerr_calIncorrectPassword = -1074118596
279
+ INCORRECT_PASSWORD = -1074118596
280
+
281
+ #: The external calibration password contains too many characters.
282
+ #:
283
+ #: #define NISYNC_ERROR_CAL_PASSWORD_TOO_LARGE = NISYNC_ERROR_BASE + 61
284
+ #:
285
+ #: nisyncerr_calPasswordTooLarge = -1074118595
286
+ PASSWORD_TOO_LARGE = -1074118595
287
+
288
+ #: The specified calibration operation is not permitted on this session type.
289
+ #:
290
+ #: #define NISYNC_ERROR_CAL_NOT_PERMITTED = NISYNC_ERROR_BASE + 62
291
+ #:
292
+ #: nisyncerr_calNotPermitted = -1074118594
293
+ NOT_PERMITTED = -1074118594
294
+
295
+ #: A resource necessary to complete the specified operation is not available; therefore, the operation cannot be completed.
296
+ #:
297
+ #: #define NISYNC_ERROR_RSRC_UNAVAILABLE = NISYNC_ERROR_BASE + 70
298
+ #:
299
+ #: nisyncerr_rsrcUnavailable = -1074118586
300
+ RESOURCE_UNAVAILABLE = -1074118586
301
+
302
+ #: A resource necessary to complete the specified operation is already reserved by a previous operation and cannot be shared; therefore, the operation cannot be completed.
303
+ #:
304
+ #: #define NISYNC_ERROR_RSRC_RESERVED = NISYNC_ERROR_BASE + 71
305
+ #:
306
+ #: nisyncerr_rsrcReserved = -1074118585
307
+ RESOURCE_RESERVED = -1074118585
308
+
309
+ #: A resource necessary to complete the specified operation is not reserved and should have already been; therefore, the operation cannot be completed
310
+ #:
311
+ #: #define NISYNC_ERROR_RSRC_NOT_RESERVED = NISYNC_ERROR_BASE + 72
312
+ #:
313
+ #: nisyncerr_rsrcNotReserved = -1074118584
314
+ RESOURCE_NOT_RESERVED = -1074118584
315
+
316
+ #: A hardware buffer necessary to complete the specified operation is unexpectedly full; therefore, the operation cannot be completed.
317
+ #:
318
+ #: #define NISYNC_ERROR_HW_BUFFER_FULL = NISYNC_ERROR_BASE + 73
319
+ #:
320
+ #: nisyncerr_hwBufferFull = -1074118583
321
+ HARDWARE_BUFFER_FULL = -1074118583
322
+
323
+ #: A software buffer necessary to complete the specified operation is unexpectedly full; therefore, the operation cannot be completed.
324
+ #:
325
+ #: #define NISYNC_ERROR_SW_BUFFER_FULL = NISYNC_ERROR_BASE + 74
326
+ #:
327
+ #: nisyncerr_swBufferFull = -1074118582
328
+ SOFTWARE_BUFFER_FULL = -1074118582
329
+
330
+ #: A network socket necessary to complete the specified operation has generated a failure; therefore, the operation cannot be completed.
331
+ #:
332
+ #: #define NISYNC_ERROR_SOCKET_FAILURE = NISYNC_ERROR_BASE + 75
333
+ #:
334
+ #: nisyncerr_socketFailure = -1074118581
335
+ SOCKET_FAILED = -1074118581
336
+
337
+ #: The specified operation cannot be performed because a session has been aborted or a device has been removed from the system. Handle this situation as required by the application and then, if appropriate, attempt to perform the operation again.
338
+ #:
339
+ #: #define NISYNC_ERROR_SESSION_ABORTED = NISYNC_ERROR_BASE + 76
340
+ #:
341
+ #: nisyncerr_sessionAborted = -1074118580
342
+ SESSION_ABORTED = -1074118580
343
+
344
+ #: The specified operation cannot be performed because a session is in the process of being aborted or a device is in the process of being removed from the system. Wait until the abort operation is complete, and attempt to perform the operation again.
345
+ #:
346
+ #: #define NISYNC_ERROR_SESSION_ABORTING = NISYNC_ERROR_BASE + 77
347
+ #:
348
+ #: nisyncerr_sessionAborting = -1074118579
349
+ SESSION_ABORTING = -1074118579
350
+
351
+ #: The specified operation cannot be performed since the Active Item was not specified.
352
+ #:
353
+ #: #define NISYNC_ERROR_TERMINAL_NOT_SPECIFIED = NISYNC_ERROR_BASE + 78
354
+ #:
355
+ #: nisyncerr_terminalNotSpecified = -1074118578
356
+ TERMINAL_NOT_SPECIFIED = -1074118578
357
+
358
+ #: A 1588 time value has overflowed. The resulting value is not accurate.
359
+ #:
360
+ #: #define NISYNC_ERROR_TIME_OVERFLOW = NISYNC_ERROR_BASE + 80
361
+ #:
362
+ #: nisyncerr_timeOverflow = -1074118576
363
+ TIME_OVERFLOW = -1074118576
364
+
365
+ #: The specified time value is too early to be represented as a 1588 time value.
366
+ #:
367
+ #: #define NISYNC_ERROR_TIME_TOO_EARLY = NISYNC_ERROR_BASE + 81
368
+ #:
369
+ #: nisyncerr_timeTooEarly = -1074118575
370
+ TIME_TOO_EARLY = -1074118575
371
+
372
+ #: The specified time value is too late to be represetned as a 1588 time value.
373
+ #:
374
+ #: #define NISYNC_ERROR_TIME_TOO_LATE = NISYNC_ERROR_BASE + 82
375
+ #:
376
+ #: nisyncerr_timeTooLate = -1074118574
377
+ TIME_TOO_LATE = -1074118574
378
+
379
+ #: The Precision Time Protocol (PTP) has already been started on this device; therefore, it cannot be started again.
380
+ #:
381
+ #: #define NISYNC_ERROR_PTP_ALREADY_STARTED = NISYNC_ERROR_BASE + 83
382
+ #:
383
+ #: nisyncerr_ptpAlreadyStarted = -1074118573
384
+ PTP_ALREADY_STARTED = -1074118573
385
+
386
+ #: The Precision Time Protocol (PTP) has not been started on this device; therefore, it cannot be stopped.
387
+ #:
388
+ #: #define NISYNC_ERROR_PTP_NOT_STARTED = NISYNC_ERROR_BASE + 84
389
+ #:
390
+ #: nisyncerr_ptpNotStarted = -1074118572
391
+ PTP_NOT_STARTED = -1074118572
392
+
393
+ #: The specified attribute cannot be set when the Precision Time Protocol (PTP) is in its current state.
394
+ #:
395
+ #: #define NISYNC_ERROR_INVALID_CLOCK_STATE = NISYNC_ERROR_BASE + 85
396
+ #:
397
+ #: nisyncerr_invalidClockState = -1074118571
398
+ CLOCK_STATE_INVALID = -1074118571
399
+
400
+ #: The IP address for the specified device cannot be determined; therefore, the specified operation cannot be completed.
401
+ #:
402
+ #: #define NISYNC_ERROR_IP_ADDRESS = NISYNC_ERROR_BASE + 86
403
+ #:
404
+ #: nisyncerr_ipAddress = -1074118570
405
+ IP_ADDRESS = -1074118570
406
+
407
+ #: The time for the specified future time event is too soon, or may be in the past, and cannot be programmed in the device before it would occur.
408
+ #:
409
+ #: #define NISYNC_ERROR_FUTURE_TIME_EVENT_TOO_SOON = NISYNC_ERROR_BASE + 87
410
+ #:
411
+ #: nisyncerr_futureTimeEventTooSoon = -1074118569
412
+ FUTURE_TIME_EVENT_TOO_SOON = -1074118569
413
+
414
+ #: A clock with the specified period is too short to be generated by the device.
415
+ #:
416
+ #: #define NISYNC_ERROR_CLOCK_PERIOD_TOO_SHORT = NISYNC_ERROR_BASE + 88
417
+ #:
418
+ #: nisyncerr_clockPeriodTooShort = -1074118568
419
+ CLOCK_PERIOD_TOO_SHORT = -1074118568
420
+
421
+ #: A future time event with the same time and same terminal as the specified future time event has already been created. Multiple future time events on the same terminal at the same time cannot be created.
422
+ #:
423
+ #: #define NISYNC_ERROR_DUP_FUTURE_TIME_EVENT = NISYNC_ERROR_BASE + 89
424
+ #:
425
+ #: nisyncerr_dupFutureTimeEvent = -1074118567
426
+ DUPLICATE_FUTURE_TIME_EVENT = -1074118567
427
+
428
+ #: The specified sync interval for this 1588 clock is different than the sync interval specified for other 1588 clocks participating in the PTP. Adjust the sync interval on this 1588 clock or the other 1588 clocks participating in the PTP to the same value.
429
+ #:
430
+ #: #define NISYNC_ERROR_SYNC_INTERVAL_MISMACH = NISYNC_ERROR_BASE + 90
431
+ #:
432
+ #: nisyncerr_syncIntervalMismach = -1074118566
433
+ SYNC_INTERVAL_MISMACH = -1074118566
434
+
435
+ #: The specified initial time is invalid. Initial times must be after 0 hours 1 January 2000 and before 0 hours 1 January 2100.
436
+ #:
437
+ #: #define NISYNC_ERROR_INVALID_INITIAL_TIME = NISYNC_ERROR_BASE + 91
438
+ #:
439
+ #: nisyncerr_invalidInitialTime = -1074118565
440
+ INITIAL_TIME_INVALID = -1074118565
441
+
442
+ #: The specified 1588 clock adjustment offset is too large. The clock adjustment cannot be more than +1 seconds or less than -1 seconds.
443
+ #:
444
+ #: #define NISYNC_ERROR_CLK_ADJ_TOO_LARGE = NISYNC_ERROR_BASE + 92
445
+ #:
446
+ #: nisyncerr_clkAdjTooLarge = -1074118564
447
+ CLOCK_ADJUSTMENT_TOO_LARGE = -1074118564
448
+
449
+ #: A clock with the specified period is too large to be generated by the device.
450
+ #:
451
+ #: #define NISYNC_ERROR_CLOCK_PERIOD_TOO_LARGE = NISYNC_ERROR_BASE + 93
452
+ #:
453
+ #: nisyncerr_clockPeriodTooLarge = -1074118563
454
+ CLOCK_PERIOD_TOO_LARGE = -1074118563
455
+
456
+ #: The network interface associated with the device was not found. Ensure that the associated NIC (network interface controller) is installed and enabled.
457
+ #:
458
+ #: #define NISYNC_ERROR_NETWORK_ADAPTER_NOT_FOUND = NISYNC_ERROR_BASE + 94
459
+ #:
460
+ #: nisyncerr_networkAdapterNotFound = -1074118562
461
+ NETWORK_ADAPTER_NOT_FOUND = -1074118562
462
+
463
+ #: There are no shared trigger lines between the two devices which are acceptable to both devices. Consider routing the signal through the I/O connectors of the two devices, if applicable.
464
+ #:
465
+ #: #define NISYNC_ERROR_NO_COMMON_TRIG_LINE_FOR_ROUTE = NISYNC_ERROR_BASE + 95
466
+ #:
467
+ #: nisyncerr_noCommonTrigLineForRoute = -1074118561
468
+ NO_COMMON_TRIGGER_LINE_FOR_ROUTE = -1074118561
469
+
470
+ #: This device does not support timestamp decimation.
471
+ #:
472
+ #: #define NISYNC_ERROR_TIMESTAMP_DECIMATION_NOT_SUPPORTED = NISYNC_ERROR_BASE + 96
473
+ #:
474
+ #: nisyncerr_timestampDecimationNotSupported = -1074118560
475
+ TIMESTAMP_DECIMATION_NOT_SUPPORTED = -1074118560
476
+
477
+ #: The timestamp decimation count must be greater than 0 for this device.
478
+ #:
479
+ #: #define NISYNC_ERROR_TIMESTAMP_DECIMATION_COUNT_TOO_SMALL = NISYNC_ERROR_BASE + 97
480
+ #:
481
+ #: nisyncerr_timestampDecimationCountTooSmall = -1074118559
482
+ TIMESTAMP_DECIMATION_COUNT_TOO_SMALL = -1074118559
483
+
484
+ #: The specified timestamp decimation count is too great for this device.
485
+ #:
486
+ #: #define NISYNC_ERROR_TIMESTAMP_DECIMATION_COUNT_TOO_LARGE = NISYNC_ERROR_BASE + 98
487
+ #:
488
+ #: nisyncerr_timestampDecimationCountTooLarge = -1074118558
489
+ TIMESTAMP_DECIMATION_COUNT_TOO_LARGE = -1074118558
490
+
491
+ #: The specified future time event violates the rearm time of the future time event engine.
492
+ #:
493
+ #: #define NISYNC_ERROR_FUTURE_TIME_EVENT_REARM_TIME_VIOLATION = NISYNC_ERROR_BASE + 99
494
+ #:
495
+ #: nisyncerr_futureTimeEventRearmTimeViolation = -1074118557
496
+ FUTURE_TIME_EVENT_REARM_TIME_VIOLATION = -1074118557
497
+
498
+ #: Board time was snapped back during measurement.
499
+ #:
500
+ #: #define NISYNC_ERROR_TIME_SNAPPED = NISYNC_ERROR_BASE + 100
501
+ #:
502
+ #: nisyncerr_timeSnapped = -1074118556
503
+ TIME_SNAPPED = -1074118556
504
+
505
+ #: The requested property is not supported by the time reference specified on the Active Item.
506
+ #:
507
+ #: #define NISYNC_ERROR_TR_TYPE_MISMATCH = NISYNC_ERROR_BASE + 101
508
+ #:
509
+ #: nisyncerr_trTypeMismatch = -1074118555
510
+ TIME_REFERENCE_TYPE_MISMATCH = -1074118555
511
+
512
+ #: The requested time reference instance was not found.
513
+ #:
514
+ #: #define NISYNC_ERROR_TR_INSTANCE_NOT_FOUND = NISYNC_ERROR_BASE + 102
515
+ #:
516
+ #: nisyncerr_trInstanceNotFound = -1074118554
517
+ TIME_REFERENCE_INSTANCE_NOT_FOUND = -1074118554
518
+
519
+ #: The data received from the remote device could not be interpreted. Try to perform the operation again.
520
+ #:
521
+ #: #define NISYNC_ERROR_REMOTE_DEVICE_READ_FAILURE = NISYNC_ERROR_BASE + 103
522
+ #:
523
+ #: nisyncerr_remoteDeviceReadFailure = -1074118553
524
+ REMOTE_DEVICE_READ_FAILED = -1074118553
525
+
526
+ #: A failure occured while communicating with the remote device. Ensure the remote device is accessible.
527
+ #:
528
+ #: #define NISYNC_ERROR_REMOTE_DEVICE_COMMUNICATION_FAILURE = NISYNC_ERROR_BASE + 104
529
+ #:
530
+ #: nisyncerr_remoteDeviceCommunicationFailure = -1074118552
531
+ REMOTE_DEVICE_COMMUNICATION_FAILED = -1074118552
532
+
533
+ #: Unable to load an internal library. If the error persists contact NI support.
534
+ #:
535
+ #: #define NISYNC_ERROR_LIB_LOAD_FAILURE = NISYNC_ERROR_BASE + 105
536
+ #:
537
+ #: nisyncerr_libLoadFailure = -1074118551
538
+ LIBRARY_LOAD_FAILED = -1074118551
539
+
540
+ #: The resource name format is invalid.
541
+ #:
542
+ #: #define NISYNC_ERROR_INVALID_RESOURCE_NAME_FORMAT = NISYNC_ERROR_BASE + 106
543
+ #:
544
+ #: nisyncerr_invalidResourceNameFormat = -1074118550
545
+ RESOURCE_NAME_FORMAT_INVALID = -1074118550
546
+
547
+ #: The specified time reference already exists.
548
+ #:
549
+ #: #define NISYNC_ERROR_TR_INSTANCE_ALREADY_EXISTS = NISYNC_ERROR_BASE + 107
550
+ #:
551
+ #: nisyncerr_trInstanceAlreadyExists = -1074118549
552
+ TIME_REFERENCE_INSTANCE_ALREADY_EXISTS = -1074118549
553
+
554
+ #: Requested resource not found on a remote device. This may be because the device was not reachable or has experienced an internal error. It may also mean you need to update software or firmware on the remote device.
555
+ #:
556
+ #: #define NISYNC_ERROR_REMOTE_DEVICE_RESOURCE_NOT_FOUND = NISYNC_ERROR_BASE + 108
557
+ #:
558
+ #: nisyncerr_remoteDeviceResourceNotFound = -1074118548
559
+ REMOTE_DEVICE_RESOURCE_NOT_FOUND = -1074118548
560
+
561
+ #: The time reference you are trying to enable conflicts with a time reference already running on the same interface. Disable the conflicting time reference and retry the operation.
562
+ #:
563
+ #: #define NISYNC_ERROR_CONFLICTING_TR_INSTANCES = NISYNC_ERROR_BASE + 109
564
+ #:
565
+ #: nisyncerr_conflictingTrInstances = -1074118547
566
+ CONFLICTING_TIME_REFERENCE_INSTANCES = -1074118547
567
+
568
+ #: The requested attribute is not currently available. This may be because the time reference is disabled, not ready, or has encountered an error.
569
+ #:
570
+ #: #define NISYNC_ERROR_TR_ATTR_NOT_FOUND = NISYNC_ERROR_BASE + 110
571
+ #:
572
+ #: nisyncerr_trAttrNotFound = -1074118546
573
+ TIME_REFERENCE_ATTRIBUTE_NOT_FOUND = -1074118546
574
+
575
+ #: A failure occured while communicating with a required software service running on the device. Restart the device. If the error persists, contact NI support.
576
+ #:
577
+ #: #define NISYNC_ERROR_COMMUNICATIONS_FAULT = NISYNC_ERROR_BASE + 111
578
+ #:
579
+ #: nisyncerr_communicationsFault = -1074118545
580
+ COMMUNICATIONS_FAILED = -1074118545
581
+
582
+ #: The specified attribute is not supported.
583
+ #:
584
+ #: #define NISYNC_ERROR_NSUP_ATTR = VI_ERROR_NSUP_ATTR
585
+ #:
586
+ #: nisyncerr_nsupAttr = -1073807331
587
+ ATTRIBUTE_NOT_SUPPORTED = -1073807331
588
+
589
+ #: The specified attribute state is not supported.
590
+ #:
591
+ #: #define NISYNC_ERROR_NSUP_ATTR_STATE = VI_ERROR_NSUP_ATTR_STATE
592
+ #:
593
+ #: nisyncerr_nsupAttrState = -1073807330
594
+ ATTRIBUTE_STATE_NOT_SUPPORTED = -1073807330
595
+
596
+ #: The specified attribute is read-only.
597
+ #:
598
+ #: #define NISYNC_ERROR_ATTR_READONLY = VI_ERROR_ATTR_READONLY
599
+ #:
600
+ #: nisyncerr_attrReadonly = -1073807329
601
+ ATTRIBUTE_READONLY = -1073807329
602
+
603
+ #: The specified destination terminal is in use.
604
+ #:
605
+ #: #define NISYNC_ERROR_DEST_TERMINAL_IN_USE = VI_ERROR_LINE_IN_USE
606
+ #:
607
+ #: nisyncerr_destTerminalInUse = -1073807294
608
+ DESTINATION_TERMINAL_IN_USE = -1073807294
609
+
610
+ #: A parameter for this operation is invalid.
611
+ #:
612
+ #: #define NISYNC_ERROR_INV_PARAMETER = VI_ERROR_INV_PARAMETER
613
+ #:
614
+ #: nisyncerr_invParameter = -1073807240
615
+ PARAMETER_INVALID = -1073807240
616
+
617
+ #: Insufficient system resources to perform necessary memory allocation.
618
+ #:
619
+ #: #define NISYNC_ERROR_ALLOC = VI_ERROR_ALLOC
620
+ #:
621
+ #: nisyncerr_allocationFailed = -1073807300
622
+ ALLOCATION_FAILED = -1073807300
623
+
624
+ #: The given session or object reference is invalid.
625
+ #:
626
+ #: #define NISYNC_ERROR_INV_OBJECT = VI_ERROR_INV_OBJECT
627
+ #:
628
+ #: nisyncerr_invalidObject = -1073807346
629
+ OBJECT_INVALID = -1073807346
630
+
631
+ #: Unknown system error (miscellaneous error).
632
+ #:
633
+ #: #define NISYNC_ERROR_SYSTEM_ERROR = VI_ERROR_SYSTEM_ERROR
634
+ #:
635
+ #: nisyncerr_systemError = -1073807360
636
+ SYSTEM_ERROR = -1073807360