datex2-xml2json 0.0.1__py3-none-any.whl
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- datex2_xml2json/__init__.py +0 -0
- datex2_xml2json/json_validator.py +36 -0
- datex2_xml2json/merge.py +39 -0
- datex2_xml2json/schema/Baustellen-4-00-00.sch +7 -0
- datex2_xml2json/schema/DATEXIISchema_2_2_0.xsd +4707 -0
- datex2_xml2json/schema/DATEXIISchema_2_2_3.xsd +6783 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/.DS_Store +0 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_AfirEnergyInfrastructure.json +2455 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_AfirFacilities.json +2809 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_Common.json +3651 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_CommonExtension.json +919 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_ControlledZone.json +1070 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_D2Payload.json +11 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_EnergyInfrastructure.json +1924 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_Facilities.json +2858 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_FaultAndStatus.json +1415 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_LocationExtension.json +186 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_LocationReferencing.json +4847 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_Parking.json +5314 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_ReroutingManagementEnhanced.json +1160 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_RoadTrafficData.json +1938 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_Situation.json +8040 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_TrafficManagementPlan.json +2358 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_TrafficRegulation.json +3377 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_UrbanExtensions.json +194 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/DATEXII_3_Vms.json +2544 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/.DS_Store +0 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_AfirEnergyInfrastructure.xsd +2102 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_AfirFacilities.xsd +2060 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_Common.xsd +4152 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_CommonExtension.xsd +1102 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_ControlledZone.xsd +601 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_D2Payload.xsd +280 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_EnergyInfrastructure.xsd +1761 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_Facilities.xsd +2037 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_FaultAndStatus.xsd +1076 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_LocationExtension.xsd +196 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_LocationReferencing.xsd +4132 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_Parking.xsd +4025 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_ReroutingManagementEnhanced.xsd +997 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_RoadTrafficData.xsd +1273 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_Situation.xsd +5777 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_TrafficManagementPlan.xsd +1184 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_TrafficRegulation.xsd +2611 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_UrbanExtensions.xsd +148 -0
- datex2_xml2json/schema/DATEXII_3.7_Profile/xml/DATEXII_3_Vms.xsd +2290 -0
- datex2_xml2json/schema/MDM_BaustellenInfoDigitalRoadworksProfile_04-03-00.xsd +2401 -0
- datex2_xml2json/schema/MDM_Datenmodell_Baustellen_04-00-00.xsd +3232 -0
- datex2_xml2json/schema/cifs_schema.json +161 -0
- datex2_xml2json/transform/.DS_Store +0 -0
- datex2_xml2json/transform/__init__.py +13 -0
- datex2_xml2json/transform/base.py +79 -0
- datex2_xml2json/transform/cifs_transformer.py +275 -0
- datex2_xml2json/transform/geojson_geometry_transformer.py +159 -0
- datex2_xml2json/transform/geoparquet_transformer.py +160 -0
- datex2_xml2json/transform/jsonata_transformer.py +100 -0
- datex2_xml2json/transform/roads_regio_transformer.py +88 -0
- datex2_xml2json/transform/source_setter.py +42 -0
- datex2_xml2json/transform/transformation_rules.py +526 -0
- datex2_xml2json/transformer.py +197 -0
- datex2_xml2json/util.py +141 -0
- datex2_xml2json-0.0.1.dist-info/METADATA +176 -0
- datex2_xml2json-0.0.1.dist-info/RECORD +65 -0
- datex2_xml2json-0.0.1.dist-info/WHEEL +4 -0
- datex2_xml2json-0.0.1.dist-info/licenses/LICENSE.md +179 -0
|
@@ -0,0 +1,2102 @@
|
|
|
1
|
+
<?xml version="1.0" encoding="utf-8" standalone="no"?>
|
|
2
|
+
<xs:schema elementFormDefault="qualified" attributeFormDefault="unqualified" xmlns:aegi="http://datex2.eu/schema/3/afirEnergyInfrastructure" version="3.7" targetNamespace="http://datex2.eu/schema/3/afirEnergyInfrastructure" xmlns:com="http://datex2.eu/schema/3/common" xmlns:afac="http://datex2.eu/schema/3/afirFacilities" xmlns:loc="http://datex2.eu/schema/3/locationReferencing" xmlns:xs="http://www.w3.org/2001/XMLSchema">
|
|
3
|
+
<xs:import namespace="http://datex2.eu/schema/3/locationReferencing" schemaLocation="DATEXII_3_LocationReferencing.xsd" />
|
|
4
|
+
<xs:import namespace="http://datex2.eu/schema/3/afirFacilities" schemaLocation="DATEXII_3_AfirFacilities.xsd" />
|
|
5
|
+
<xs:import namespace="http://datex2.eu/schema/3/common" schemaLocation="DATEXII_3_Common.xsd" />
|
|
6
|
+
<xs:complexType name="_AuthenticationAndIdentificationEnum">
|
|
7
|
+
<xs:simpleContent>
|
|
8
|
+
<xs:extension base="aegi:AuthenticationAndIdentificationEnum">
|
|
9
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
10
|
+
</xs:extension>
|
|
11
|
+
</xs:simpleContent>
|
|
12
|
+
</xs:complexType>
|
|
13
|
+
<xs:complexType name="_BioethanolTypeEnum">
|
|
14
|
+
<xs:simpleContent>
|
|
15
|
+
<xs:extension base="aegi:BioethanolTypeEnum">
|
|
16
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
17
|
+
</xs:extension>
|
|
18
|
+
</xs:simpleContent>
|
|
19
|
+
</xs:complexType>
|
|
20
|
+
<xs:complexType name="_ChargingModeEnum">
|
|
21
|
+
<xs:simpleContent>
|
|
22
|
+
<xs:extension base="aegi:ChargingModeEnum">
|
|
23
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
24
|
+
</xs:extension>
|
|
25
|
+
</xs:simpleContent>
|
|
26
|
+
</xs:complexType>
|
|
27
|
+
<xs:complexType name="_ChargingPointUsageTypeEnum">
|
|
28
|
+
<xs:simpleContent>
|
|
29
|
+
<xs:extension base="aegi:ChargingPointUsageTypeEnum">
|
|
30
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
31
|
+
</xs:extension>
|
|
32
|
+
</xs:simpleContent>
|
|
33
|
+
</xs:complexType>
|
|
34
|
+
<xs:complexType name="_ConnectorFormatTypeEnum">
|
|
35
|
+
<xs:simpleContent>
|
|
36
|
+
<xs:extension base="aegi:ConnectorFormatTypeEnum">
|
|
37
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
38
|
+
</xs:extension>
|
|
39
|
+
</xs:simpleContent>
|
|
40
|
+
</xs:complexType>
|
|
41
|
+
<xs:complexType name="_ConnectorTypeEnum">
|
|
42
|
+
<xs:simpleContent>
|
|
43
|
+
<xs:extension base="aegi:ConnectorTypeEnum">
|
|
44
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
45
|
+
</xs:extension>
|
|
46
|
+
</xs:simpleContent>
|
|
47
|
+
</xs:complexType>
|
|
48
|
+
<xs:complexType name="_CurrentTypeEnum">
|
|
49
|
+
<xs:simpleContent>
|
|
50
|
+
<xs:extension base="aegi:CurrentTypeEnum">
|
|
51
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
52
|
+
</xs:extension>
|
|
53
|
+
</xs:simpleContent>
|
|
54
|
+
</xs:complexType>
|
|
55
|
+
<xs:complexType name="_DeliveryUnitEnum">
|
|
56
|
+
<xs:simpleContent>
|
|
57
|
+
<xs:extension base="aegi:DeliveryUnitEnum">
|
|
58
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
59
|
+
</xs:extension>
|
|
60
|
+
</xs:simpleContent>
|
|
61
|
+
</xs:complexType>
|
|
62
|
+
<xs:complexType name="_DieselVehicleTypeEnum">
|
|
63
|
+
<xs:simpleContent>
|
|
64
|
+
<xs:extension base="aegi:DieselVehicleTypeEnum">
|
|
65
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
66
|
+
</xs:extension>
|
|
67
|
+
</xs:simpleContent>
|
|
68
|
+
</xs:complexType>
|
|
69
|
+
<xs:complexType name="_ElectricEnergySourceTypeEnum">
|
|
70
|
+
<xs:simpleContent>
|
|
71
|
+
<xs:extension base="aegi:ElectricEnergySourceTypeEnum">
|
|
72
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
73
|
+
</xs:extension>
|
|
74
|
+
</xs:simpleContent>
|
|
75
|
+
</xs:complexType>
|
|
76
|
+
<xs:complexType name="_EnergyInfrastructureSiteTypeEnum">
|
|
77
|
+
<xs:simpleContent>
|
|
78
|
+
<xs:extension base="aegi:EnergyInfrastructureSiteTypeEnum">
|
|
79
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
80
|
+
</xs:extension>
|
|
81
|
+
</xs:simpleContent>
|
|
82
|
+
</xs:complexType>
|
|
83
|
+
<xs:complexType name="_EnergyInfrastructureTableVersionedReference">
|
|
84
|
+
<xs:complexContent>
|
|
85
|
+
<xs:extension base="com:VersionedReference">
|
|
86
|
+
<xs:attribute name="targetClass" type="xs:string" use="required" fixed="aegi:EnergyInfrastructureTable" />
|
|
87
|
+
</xs:extension>
|
|
88
|
+
</xs:complexContent>
|
|
89
|
+
</xs:complexType>
|
|
90
|
+
<xs:complexType name="_EnergyRateReference">
|
|
91
|
+
<xs:complexContent>
|
|
92
|
+
<xs:extension base="com:Reference">
|
|
93
|
+
<xs:attribute name="targetClass" type="xs:string" use="required" fixed="aegi:EnergyRate" />
|
|
94
|
+
</xs:extension>
|
|
95
|
+
</xs:complexContent>
|
|
96
|
+
</xs:complexType>
|
|
97
|
+
<xs:complexType name="_GasConnectorTypeEnum">
|
|
98
|
+
<xs:simpleContent>
|
|
99
|
+
<xs:extension base="aegi:GasConnectorTypeEnum">
|
|
100
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
101
|
+
</xs:extension>
|
|
102
|
+
</xs:simpleContent>
|
|
103
|
+
</xs:complexType>
|
|
104
|
+
<xs:complexType name="_HydrogenFuellingProcessProtocolEnum">
|
|
105
|
+
<xs:simpleContent>
|
|
106
|
+
<xs:extension base="aegi:HydrogenFuellingProcessProtocolEnum">
|
|
107
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
108
|
+
</xs:extension>
|
|
109
|
+
</xs:simpleContent>
|
|
110
|
+
</xs:complexType>
|
|
111
|
+
<xs:complexType name="_HydrogenRefuellingModeEnum">
|
|
112
|
+
<xs:simpleContent>
|
|
113
|
+
<xs:extension base="aegi:HydrogenRefuellingModeEnum">
|
|
114
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
115
|
+
</xs:extension>
|
|
116
|
+
</xs:simpleContent>
|
|
117
|
+
</xs:complexType>
|
|
118
|
+
<xs:complexType name="_OctaneTypeEnum">
|
|
119
|
+
<xs:simpleContent>
|
|
120
|
+
<xs:extension base="aegi:OctaneTypeEnum">
|
|
121
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
122
|
+
</xs:extension>
|
|
123
|
+
</xs:simpleContent>
|
|
124
|
+
</xs:complexType>
|
|
125
|
+
<xs:complexType name="_PetrolTypeEnum">
|
|
126
|
+
<xs:simpleContent>
|
|
127
|
+
<xs:extension base="aegi:PetrolTypeEnum">
|
|
128
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
129
|
+
</xs:extension>
|
|
130
|
+
</xs:simpleContent>
|
|
131
|
+
</xs:complexType>
|
|
132
|
+
<xs:complexType name="_PriceTypeEnum">
|
|
133
|
+
<xs:simpleContent>
|
|
134
|
+
<xs:extension base="aegi:PriceTypeEnum">
|
|
135
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
136
|
+
</xs:extension>
|
|
137
|
+
</xs:simpleContent>
|
|
138
|
+
</xs:complexType>
|
|
139
|
+
<xs:complexType name="_RatePolicyEnum">
|
|
140
|
+
<xs:simpleContent>
|
|
141
|
+
<xs:extension base="aegi:RatePolicyEnum">
|
|
142
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
143
|
+
</xs:extension>
|
|
144
|
+
</xs:simpleContent>
|
|
145
|
+
</xs:complexType>
|
|
146
|
+
<xs:complexType name="_RefillPointStatusEnum">
|
|
147
|
+
<xs:simpleContent>
|
|
148
|
+
<xs:extension base="aegi:RefillPointStatusEnum">
|
|
149
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
150
|
+
</xs:extension>
|
|
151
|
+
</xs:simpleContent>
|
|
152
|
+
</xs:complexType>
|
|
153
|
+
<xs:complexType name="_ServiceTypeEnum">
|
|
154
|
+
<xs:simpleContent>
|
|
155
|
+
<xs:extension base="aegi:ServiceTypeEnum">
|
|
156
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
157
|
+
</xs:extension>
|
|
158
|
+
</xs:simpleContent>
|
|
159
|
+
</xs:complexType>
|
|
160
|
+
<xs:complexType name="_SmartRechargingServicesEnum">
|
|
161
|
+
<xs:simpleContent>
|
|
162
|
+
<xs:extension base="aegi:SmartRechargingServicesEnum">
|
|
163
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
164
|
+
</xs:extension>
|
|
165
|
+
</xs:simpleContent>
|
|
166
|
+
</xs:complexType>
|
|
167
|
+
<xs:complexType name="_VehicleToGridCommunicationTypeEnum">
|
|
168
|
+
<xs:simpleContent>
|
|
169
|
+
<xs:extension base="aegi:VehicleToGridCommunicationTypeEnum">
|
|
170
|
+
<xs:attribute name="_extendedValue" type="xs:string" />
|
|
171
|
+
</xs:extension>
|
|
172
|
+
</xs:simpleContent>
|
|
173
|
+
</xs:complexType>
|
|
174
|
+
<xs:complexType name="AlternativeFuelsRefillPoint">
|
|
175
|
+
<xs:annotation>
|
|
176
|
+
<xs:documentation>A refill point for alternative fules like CNG,LNG,LPG,biogas or hydrogen (liquid or gaseous).</xs:documentation>
|
|
177
|
+
</xs:annotation>
|
|
178
|
+
<xs:complexContent>
|
|
179
|
+
<xs:extension base="aegi:RefillPoint">
|
|
180
|
+
<xs:sequence>
|
|
181
|
+
<xs:element name="connector" type="aegi:_GasConnectorTypeEnum" minOccurs="0" maxOccurs="unbounded">
|
|
182
|
+
<xs:annotation>
|
|
183
|
+
<xs:documentation>Information on the alternative fuels type connector at the refill point.</xs:documentation>
|
|
184
|
+
</xs:annotation>
|
|
185
|
+
</xs:element>
|
|
186
|
+
<xs:element name="otherConnector" type="com:String" minOccurs="0" maxOccurs="unbounded">
|
|
187
|
+
<xs:annotation>
|
|
188
|
+
<xs:documentation>Any other type of alternative fuels connector.</xs:documentation>
|
|
189
|
+
</xs:annotation>
|
|
190
|
+
</xs:element>
|
|
191
|
+
<xs:element name="hydrogenProcessProtocol" type="aegi:_HydrogenFuellingProcessProtocolEnum" minOccurs="0" maxOccurs="1">
|
|
192
|
+
<xs:annotation>
|
|
193
|
+
<xs:documentation>Information on which protocol is used for the fuelling process for hydrogen.</xs:documentation>
|
|
194
|
+
</xs:annotation>
|
|
195
|
+
</xs:element>
|
|
196
|
+
<xs:element name="renewableSourcesRatio" type="com:Percentage" minOccurs="0" maxOccurs="1">
|
|
197
|
+
<xs:annotation>
|
|
198
|
+
<xs:documentation>Percentage of renewable energy sources for the alternative fluel, to be indicated in %.</xs:documentation>
|
|
199
|
+
</xs:annotation>
|
|
200
|
+
</xs:element>
|
|
201
|
+
<xs:element name="pressure" type="aegi:Bar" minOccurs="0" maxOccurs="1">
|
|
202
|
+
<xs:annotation>
|
|
203
|
+
<xs:documentation>The pressure which is used for gaseous fuel.</xs:documentation>
|
|
204
|
+
</xs:annotation>
|
|
205
|
+
</xs:element>
|
|
206
|
+
<xs:element name="_alternativeFuelsRefillPointExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
207
|
+
</xs:sequence>
|
|
208
|
+
</xs:extension>
|
|
209
|
+
</xs:complexContent>
|
|
210
|
+
</xs:complexType>
|
|
211
|
+
<xs:simpleType name="Ampere">
|
|
212
|
+
<xs:annotation>
|
|
213
|
+
<xs:documentation>Ampere.</xs:documentation>
|
|
214
|
+
</xs:annotation>
|
|
215
|
+
<xs:restriction base="com:Float" />
|
|
216
|
+
</xs:simpleType>
|
|
217
|
+
<xs:simpleType name="AuthenticationAndIdentificationEnum">
|
|
218
|
+
<xs:annotation>
|
|
219
|
+
<xs:documentation>A table of authentication and/or identification methods.</xs:documentation>
|
|
220
|
+
</xs:annotation>
|
|
221
|
+
<xs:restriction base="xs:string">
|
|
222
|
+
<xs:enumeration value="activeRFIDChip">
|
|
223
|
+
<xs:annotation>
|
|
224
|
+
<xs:documentation>Phone (active RFID chip).</xs:documentation>
|
|
225
|
+
</xs:annotation>
|
|
226
|
+
</xs:enumeration>
|
|
227
|
+
<xs:enumeration value="apps">
|
|
228
|
+
<xs:annotation>
|
|
229
|
+
<xs:documentation>Apps</xs:documentation>
|
|
230
|
+
</xs:annotation>
|
|
231
|
+
</xs:enumeration>
|
|
232
|
+
<xs:enumeration value="calypso">
|
|
233
|
+
<xs:annotation>
|
|
234
|
+
<xs:documentation>RFID Calypso.</xs:documentation>
|
|
235
|
+
</xs:annotation>
|
|
236
|
+
</xs:enumeration>
|
|
237
|
+
<xs:enumeration value="cashPayment">
|
|
238
|
+
<xs:annotation>
|
|
239
|
+
<xs:documentation>No specific authentication by using cash.</xs:documentation>
|
|
240
|
+
</xs:annotation>
|
|
241
|
+
</xs:enumeration>
|
|
242
|
+
<xs:enumeration value="creditCard">
|
|
243
|
+
<xs:annotation>
|
|
244
|
+
<xs:documentation>Credit card.</xs:documentation>
|
|
245
|
+
</xs:annotation>
|
|
246
|
+
</xs:enumeration>
|
|
247
|
+
<xs:enumeration value="debitCard">
|
|
248
|
+
<xs:annotation>
|
|
249
|
+
<xs:documentation>Debit card.</xs:documentation>
|
|
250
|
+
</xs:annotation>
|
|
251
|
+
</xs:enumeration>
|
|
252
|
+
<xs:enumeration value="mifareClassic">
|
|
253
|
+
<xs:annotation>
|
|
254
|
+
<xs:documentation>RFID Card / Phone NFC - Mifare Classic.</xs:documentation>
|
|
255
|
+
</xs:annotation>
|
|
256
|
+
</xs:enumeration>
|
|
257
|
+
<xs:enumeration value="mifareDesfire">
|
|
258
|
+
<xs:annotation>
|
|
259
|
+
<xs:documentation>RFID Card / Phone NFC - Mifare Desfire.</xs:documentation>
|
|
260
|
+
</xs:annotation>
|
|
261
|
+
</xs:enumeration>
|
|
262
|
+
<xs:enumeration value="nfc">
|
|
263
|
+
<xs:annotation>
|
|
264
|
+
<xs:documentation>Nearfield communication.</xs:documentation>
|
|
265
|
+
</xs:annotation>
|
|
266
|
+
</xs:enumeration>
|
|
267
|
+
<xs:enumeration value="overTheAir">
|
|
268
|
+
<xs:annotation>
|
|
269
|
+
<xs:documentation>Over the air according to ISO 15118-2 and -20.</xs:documentation>
|
|
270
|
+
</xs:annotation>
|
|
271
|
+
</xs:enumeration>
|
|
272
|
+
<xs:enumeration value="phoneDialog">
|
|
273
|
+
<xs:annotation>
|
|
274
|
+
<xs:documentation>Phone (dialog with platform).</xs:documentation>
|
|
275
|
+
</xs:annotation>
|
|
276
|
+
</xs:enumeration>
|
|
277
|
+
<xs:enumeration value="phoneSMS">
|
|
278
|
+
<xs:annotation>
|
|
279
|
+
<xs:documentation>Phone (SMS).</xs:documentation>
|
|
280
|
+
</xs:annotation>
|
|
281
|
+
</xs:enumeration>
|
|
282
|
+
<xs:enumeration value="pinpad">
|
|
283
|
+
<xs:annotation>
|
|
284
|
+
<xs:documentation>PINPAD</xs:documentation>
|
|
285
|
+
</xs:annotation>
|
|
286
|
+
</xs:enumeration>
|
|
287
|
+
<xs:enumeration value="plc">
|
|
288
|
+
<xs:annotation>
|
|
289
|
+
<xs:documentation>PLC according to ISO 15118.</xs:documentation>
|
|
290
|
+
</xs:annotation>
|
|
291
|
+
</xs:enumeration>
|
|
292
|
+
<xs:enumeration value="prepaidCard">
|
|
293
|
+
<xs:annotation>
|
|
294
|
+
<xs:documentation>Prepaid card.</xs:documentation>
|
|
295
|
+
</xs:annotation>
|
|
296
|
+
</xs:enumeration>
|
|
297
|
+
<xs:enumeration value="rfid">
|
|
298
|
+
<xs:annotation>
|
|
299
|
+
<xs:documentation>RFID</xs:documentation>
|
|
300
|
+
</xs:annotation>
|
|
301
|
+
</xs:enumeration>
|
|
302
|
+
<xs:enumeration value="website">
|
|
303
|
+
<xs:annotation>
|
|
304
|
+
<xs:documentation>Using a website.</xs:documentation>
|
|
305
|
+
</xs:annotation>
|
|
306
|
+
</xs:enumeration>
|
|
307
|
+
<xs:enumeration value="unlimitedAccess">
|
|
308
|
+
<xs:annotation>
|
|
309
|
+
<xs:documentation>No authentication/identification required.</xs:documentation>
|
|
310
|
+
</xs:annotation>
|
|
311
|
+
</xs:enumeration>
|
|
312
|
+
<xs:enumeration value="noAccess">
|
|
313
|
+
<xs:annotation>
|
|
314
|
+
<xs:documentation>No access granted.</xs:documentation>
|
|
315
|
+
</xs:annotation>
|
|
316
|
+
</xs:enumeration>
|
|
317
|
+
<xs:enumeration value="_extended" />
|
|
318
|
+
</xs:restriction>
|
|
319
|
+
</xs:simpleType>
|
|
320
|
+
<xs:simpleType name="Bar">
|
|
321
|
+
<xs:annotation>
|
|
322
|
+
<xs:documentation>A measure of pressure defined in bar.</xs:documentation>
|
|
323
|
+
</xs:annotation>
|
|
324
|
+
<xs:restriction base="com:Float" />
|
|
325
|
+
</xs:simpleType>
|
|
326
|
+
<xs:simpleType name="BioethanolTypeEnum">
|
|
327
|
+
<xs:annotation>
|
|
328
|
+
<xs:documentation>A table of different types of petrol with a share of bioethanol.</xs:documentation>
|
|
329
|
+
</xs:annotation>
|
|
330
|
+
<xs:restriction base="xs:string">
|
|
331
|
+
<xs:enumeration value="superE5">
|
|
332
|
+
<xs:annotation>
|
|
333
|
+
<xs:documentation>Petrol with 5% bioethanol.</xs:documentation>
|
|
334
|
+
</xs:annotation>
|
|
335
|
+
</xs:enumeration>
|
|
336
|
+
<xs:enumeration value="superE10">
|
|
337
|
+
<xs:annotation>
|
|
338
|
+
<xs:documentation>Petrol with 10% bioethanol.</xs:documentation>
|
|
339
|
+
</xs:annotation>
|
|
340
|
+
</xs:enumeration>
|
|
341
|
+
<xs:enumeration value="e15">
|
|
342
|
+
<xs:annotation>
|
|
343
|
+
<xs:documentation>Petrol with 15% bioethanol.</xs:documentation>
|
|
344
|
+
</xs:annotation>
|
|
345
|
+
</xs:enumeration>
|
|
346
|
+
<xs:enumeration value="e85">
|
|
347
|
+
<xs:annotation>
|
|
348
|
+
<xs:documentation>Petrol with 85% bioethanol.</xs:documentation>
|
|
349
|
+
</xs:annotation>
|
|
350
|
+
</xs:enumeration>
|
|
351
|
+
<xs:enumeration value="e100">
|
|
352
|
+
<xs:annotation>
|
|
353
|
+
<xs:documentation>Petrol with 100% bioethanol.</xs:documentation>
|
|
354
|
+
</xs:annotation>
|
|
355
|
+
</xs:enumeration>
|
|
356
|
+
<xs:enumeration value="unknown">
|
|
357
|
+
<xs:annotation>
|
|
358
|
+
<xs:documentation>The share of bioethanol is unknown.</xs:documentation>
|
|
359
|
+
</xs:annotation>
|
|
360
|
+
</xs:enumeration>
|
|
361
|
+
<xs:enumeration value="other">
|
|
362
|
+
<xs:annotation>
|
|
363
|
+
<xs:documentation>Other, less common, types of Petrol with bioethanol.</xs:documentation>
|
|
364
|
+
</xs:annotation>
|
|
365
|
+
</xs:enumeration>
|
|
366
|
+
<xs:enumeration value="_extended" />
|
|
367
|
+
</xs:restriction>
|
|
368
|
+
</xs:simpleType>
|
|
369
|
+
<xs:simpleType name="ChargingModeEnum">
|
|
370
|
+
<xs:annotation>
|
|
371
|
+
<xs:documentation>Charging mode according to IEC 61851-1 terminology.</xs:documentation>
|
|
372
|
+
</xs:annotation>
|
|
373
|
+
<xs:restriction base="xs:string">
|
|
374
|
+
<xs:enumeration value="mode1AC1p">
|
|
375
|
+
<xs:annotation>
|
|
376
|
+
<xs:documentation>Mode 1, AC 1 phase.</xs:documentation>
|
|
377
|
+
</xs:annotation>
|
|
378
|
+
</xs:enumeration>
|
|
379
|
+
<xs:enumeration value="mode1AC3p">
|
|
380
|
+
<xs:annotation>
|
|
381
|
+
<xs:documentation>Mode 1, AC 3 phases.</xs:documentation>
|
|
382
|
+
</xs:annotation>
|
|
383
|
+
</xs:enumeration>
|
|
384
|
+
<xs:enumeration value="mode2AC1p">
|
|
385
|
+
<xs:annotation>
|
|
386
|
+
<xs:documentation>Mode 2, AC 1 phase.</xs:documentation>
|
|
387
|
+
</xs:annotation>
|
|
388
|
+
</xs:enumeration>
|
|
389
|
+
<xs:enumeration value="mode2AC3p">
|
|
390
|
+
<xs:annotation>
|
|
391
|
+
<xs:documentation>Mode 2, AC 3 phases.</xs:documentation>
|
|
392
|
+
</xs:annotation>
|
|
393
|
+
</xs:enumeration>
|
|
394
|
+
<xs:enumeration value="mode3AC3p">
|
|
395
|
+
<xs:annotation>
|
|
396
|
+
<xs:documentation>Mode 3, AC 3 phases.</xs:documentation>
|
|
397
|
+
</xs:annotation>
|
|
398
|
+
</xs:enumeration>
|
|
399
|
+
<xs:enumeration value="mode4DC">
|
|
400
|
+
<xs:annotation>
|
|
401
|
+
<xs:documentation>Mode 4, DC.</xs:documentation>
|
|
402
|
+
</xs:annotation>
|
|
403
|
+
</xs:enumeration>
|
|
404
|
+
<xs:enumeration value="legacyInductive">
|
|
405
|
+
<xs:annotation>
|
|
406
|
+
<xs:documentation>Legacy-Inductive</xs:documentation>
|
|
407
|
+
</xs:annotation>
|
|
408
|
+
</xs:enumeration>
|
|
409
|
+
<xs:enumeration value="ccs">
|
|
410
|
+
<xs:annotation>
|
|
411
|
+
<xs:documentation>Charging with a combined charging solution (CCS). AC and DC are used simultaneously.</xs:documentation>
|
|
412
|
+
</xs:annotation>
|
|
413
|
+
</xs:enumeration>
|
|
414
|
+
<xs:enumeration value="other">
|
|
415
|
+
<xs:annotation>
|
|
416
|
+
<xs:documentation>Some other charging mode.</xs:documentation>
|
|
417
|
+
</xs:annotation>
|
|
418
|
+
</xs:enumeration>
|
|
419
|
+
<xs:enumeration value="unknown">
|
|
420
|
+
<xs:annotation>
|
|
421
|
+
<xs:documentation>The type of the charging mode is unknown.</xs:documentation>
|
|
422
|
+
</xs:annotation>
|
|
423
|
+
</xs:enumeration>
|
|
424
|
+
<xs:enumeration value="_extended" />
|
|
425
|
+
</xs:restriction>
|
|
426
|
+
</xs:simpleType>
|
|
427
|
+
<xs:simpleType name="ChargingPointUsageTypeEnum">
|
|
428
|
+
<xs:annotation>
|
|
429
|
+
<xs:documentation>Type of usage for an electric charging point..</xs:documentation>
|
|
430
|
+
</xs:annotation>
|
|
431
|
+
<xs:restriction base="xs:string">
|
|
432
|
+
<xs:enumeration value="electricBoat">
|
|
433
|
+
<xs:annotation>
|
|
434
|
+
<xs:documentation>Charging of electric boats.</xs:documentation>
|
|
435
|
+
</xs:annotation>
|
|
436
|
+
</xs:enumeration>
|
|
437
|
+
<xs:enumeration value="electricBike">
|
|
438
|
+
<xs:annotation>
|
|
439
|
+
<xs:documentation>Charging of E-Bikes.</xs:documentation>
|
|
440
|
+
</xs:annotation>
|
|
441
|
+
</xs:enumeration>
|
|
442
|
+
<xs:enumeration value="electricalDevices">
|
|
443
|
+
<xs:annotation>
|
|
444
|
+
<xs:documentation>Provides a plug for electrical devices (e.g. shaver, mobile phones, hair dryer, ...).</xs:documentation>
|
|
445
|
+
</xs:annotation>
|
|
446
|
+
</xs:enumeration>
|
|
447
|
+
<xs:enumeration value="electricMotorcycle">
|
|
448
|
+
<xs:annotation>
|
|
449
|
+
<xs:documentation>Charging of E-Motorcycles.</xs:documentation>
|
|
450
|
+
</xs:annotation>
|
|
451
|
+
</xs:enumeration>
|
|
452
|
+
<xs:enumeration value="electricVehicle">
|
|
453
|
+
<xs:annotation>
|
|
454
|
+
<xs:documentation>Charging of electric vehicles.</xs:documentation>
|
|
455
|
+
</xs:annotation>
|
|
456
|
+
</xs:enumeration>
|
|
457
|
+
<xs:enumeration value="lorryPowerConsumption">
|
|
458
|
+
<xs:annotation>
|
|
459
|
+
<xs:documentation>Supply for lorries with power consumption, e.g. for refrigerated goods transports.</xs:documentation>
|
|
460
|
+
</xs:annotation>
|
|
461
|
+
</xs:enumeration>
|
|
462
|
+
<xs:enumeration value="motorhomeOrCaravanSupply">
|
|
463
|
+
<xs:annotation>
|
|
464
|
+
<xs:documentation>Supply for motorhomes or caravans.</xs:documentation>
|
|
465
|
+
</xs:annotation>
|
|
466
|
+
</xs:enumeration>
|
|
467
|
+
<xs:enumeration value="overheadLineDrivenVehicles">
|
|
468
|
+
<xs:annotation>
|
|
469
|
+
<xs:documentation>The charging point supplies a overhead line, usually connected via pantographs.</xs:documentation>
|
|
470
|
+
</xs:annotation>
|
|
471
|
+
</xs:enumeration>
|
|
472
|
+
<xs:enumeration value="other">
|
|
473
|
+
<xs:annotation>
|
|
474
|
+
<xs:documentation>Other usage for the electric charging stations.</xs:documentation>
|
|
475
|
+
</xs:annotation>
|
|
476
|
+
</xs:enumeration>
|
|
477
|
+
<xs:enumeration value="_extended" />
|
|
478
|
+
</xs:restriction>
|
|
479
|
+
</xs:simpleType>
|
|
480
|
+
<xs:complexType name="Connector">
|
|
481
|
+
<xs:annotation>
|
|
482
|
+
<xs:documentation>Parameters and description of an interface that is available at the given electric charging point to connect vehicles.</xs:documentation>
|
|
483
|
+
</xs:annotation>
|
|
484
|
+
<xs:sequence>
|
|
485
|
+
<xs:element name="connectorType" type="aegi:_ConnectorTypeEnum" minOccurs="1" maxOccurs="1">
|
|
486
|
+
<xs:annotation>
|
|
487
|
+
<xs:documentation>Specification of the connector, i.e. the charging interface type.</xs:documentation>
|
|
488
|
+
</xs:annotation>
|
|
489
|
+
</xs:element>
|
|
490
|
+
<xs:element name="otherConnector" type="com:String" minOccurs="0" maxOccurs="1">
|
|
491
|
+
<xs:annotation>
|
|
492
|
+
<xs:documentation>Some other connector / charging interface.</xs:documentation>
|
|
493
|
+
</xs:annotation>
|
|
494
|
+
</xs:element>
|
|
495
|
+
<xs:element name="countryOfDomesticSocket" type="com:CountryCode" minOccurs="0" maxOccurs="unbounded">
|
|
496
|
+
<xs:annotation>
|
|
497
|
+
<xs:documentation>Countries for which the domestic socket is applicable. Only needed if explicit type of a domestic socket is not specified.</xs:documentation>
|
|
498
|
+
</xs:annotation>
|
|
499
|
+
</xs:element>
|
|
500
|
+
<xs:element name="connectorFormat" type="aegi:_ConnectorFormatTypeEnum" minOccurs="0" maxOccurs="1">
|
|
501
|
+
<xs:annotation>
|
|
502
|
+
<xs:documentation>Information on the cable type used.</xs:documentation>
|
|
503
|
+
</xs:annotation>
|
|
504
|
+
</xs:element>
|
|
505
|
+
<xs:element name="maxPowerAtSocket" type="aegi:Watt" minOccurs="1" maxOccurs="1">
|
|
506
|
+
<xs:annotation>
|
|
507
|
+
<xs:documentation>Maximum power at the socket in watts.</xs:documentation>
|
|
508
|
+
</xs:annotation>
|
|
509
|
+
</xs:element>
|
|
510
|
+
<xs:element name="voltage" type="aegi:Volt" minOccurs="0" maxOccurs="1">
|
|
511
|
+
<xs:annotation>
|
|
512
|
+
<xs:documentation>Voltage at the connector.</xs:documentation>
|
|
513
|
+
</xs:annotation>
|
|
514
|
+
</xs:element>
|
|
515
|
+
<xs:element name="maximumCurrent" type="aegi:Ampere" minOccurs="0" maxOccurs="1">
|
|
516
|
+
<xs:annotation>
|
|
517
|
+
<xs:documentation>Maximum current in ampere.</xs:documentation>
|
|
518
|
+
</xs:annotation>
|
|
519
|
+
</xs:element>
|
|
520
|
+
<xs:element name="externalIdentifier" type="afac:ExternalIdentifier" minOccurs="0" maxOccurs="unbounded" />
|
|
521
|
+
<xs:element name="_connectorExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
522
|
+
</xs:sequence>
|
|
523
|
+
</xs:complexType>
|
|
524
|
+
<xs:simpleType name="ConnectorFormatTypeEnum">
|
|
525
|
+
<xs:annotation>
|
|
526
|
+
<xs:documentation>A list of cable types used during the charging process.</xs:documentation>
|
|
527
|
+
</xs:annotation>
|
|
528
|
+
<xs:restriction base="xs:string">
|
|
529
|
+
<xs:enumeration value="cableMode2">
|
|
530
|
+
<xs:annotation>
|
|
531
|
+
<xs:documentation>The connector is an attached cable; the EV users car needs to have a fitting inlet for a mode 2 cable, common for most domestic sockets.</xs:documentation>
|
|
532
|
+
</xs:annotation>
|
|
533
|
+
</xs:enumeration>
|
|
534
|
+
<xs:enumeration value="cableMode3">
|
|
535
|
+
<xs:annotation>
|
|
536
|
+
<xs:documentation>The connector is an attached cable; the EV users car needs to have a fitting inlet for a mode 3 cable, can be used for Type 1 and Type 2 sockets.</xs:documentation>
|
|
537
|
+
</xs:annotation>
|
|
538
|
+
</xs:enumeration>
|
|
539
|
+
<xs:enumeration value="otherCable">
|
|
540
|
+
<xs:annotation>
|
|
541
|
+
<xs:documentation>The connector is an attached cable; the EV users car needs to have a fitting inlet.</xs:documentation>
|
|
542
|
+
</xs:annotation>
|
|
543
|
+
</xs:enumeration>
|
|
544
|
+
<xs:enumeration value="socket">
|
|
545
|
+
<xs:annotation>
|
|
546
|
+
<xs:documentation>The connector is a socket; the EV user needs to bring a fitting plug.</xs:documentation>
|
|
547
|
+
</xs:annotation>
|
|
548
|
+
</xs:enumeration>
|
|
549
|
+
<xs:enumeration value="_extended" />
|
|
550
|
+
</xs:restriction>
|
|
551
|
+
</xs:simpleType>
|
|
552
|
+
<xs:simpleType name="ConnectorTypeEnum">
|
|
553
|
+
<xs:annotation>
|
|
554
|
+
<xs:documentation>A table of commonly used connectors / charging interfaces.</xs:documentation>
|
|
555
|
+
</xs:annotation>
|
|
556
|
+
<xs:restriction base="xs:string">
|
|
557
|
+
<xs:enumeration value="chademo">
|
|
558
|
+
<xs:annotation>
|
|
559
|
+
<xs:documentation>CHAdeMO, 600 V DC. Used mostly in Japan.</xs:documentation>
|
|
560
|
+
</xs:annotation>
|
|
561
|
+
</xs:enumeration>
|
|
562
|
+
<xs:enumeration value="cee3">
|
|
563
|
+
<xs:annotation>
|
|
564
|
+
<xs:documentation>CEE3, 230 V, 16 A.</xs:documentation>
|
|
565
|
+
</xs:annotation>
|
|
566
|
+
</xs:enumeration>
|
|
567
|
+
<xs:enumeration value="cee5">
|
|
568
|
+
<xs:annotation>
|
|
569
|
+
<xs:documentation>CEE5, 400 V, 16-63 A.</xs:documentation>
|
|
570
|
+
</xs:annotation>
|
|
571
|
+
</xs:enumeration>
|
|
572
|
+
<xs:enumeration value="yazaki">
|
|
573
|
+
<xs:annotation>
|
|
574
|
+
<xs:documentation>Yazaki, 400 VDC, 125 A, Asian standard.</xs:documentation>
|
|
575
|
+
</xs:annotation>
|
|
576
|
+
</xs:enumeration>
|
|
577
|
+
<xs:enumeration value="domestic">
|
|
578
|
+
<xs:annotation>
|
|
579
|
+
<xs:documentation>A domestic socket of unspecified type. Applicable countries should be specified in separate attribute.</xs:documentation>
|
|
580
|
+
</xs:annotation>
|
|
581
|
+
</xs:enumeration>
|
|
582
|
+
<xs:enumeration value="domesticAType">
|
|
583
|
+
<xs:annotation>
|
|
584
|
+
<xs:documentation>Domestic socket type A (mainly used in the USA, Canada, Mexico & Japan).</xs:documentation>
|
|
585
|
+
</xs:annotation>
|
|
586
|
+
</xs:enumeration>
|
|
587
|
+
<xs:enumeration value="domesticBType">
|
|
588
|
+
<xs:annotation>
|
|
589
|
+
<xs:documentation>Domestic socket type B (mainly used in the USA, Canada & Mexico).</xs:documentation>
|
|
590
|
+
</xs:annotation>
|
|
591
|
+
</xs:enumeration>
|
|
592
|
+
<xs:enumeration value="domesticCType">
|
|
593
|
+
<xs:annotation>
|
|
594
|
+
<xs:documentation>Domestic socket type C (commonly used in Europe, South America & Asia).</xs:documentation>
|
|
595
|
+
</xs:annotation>
|
|
596
|
+
</xs:enumeration>
|
|
597
|
+
<xs:enumeration value="domesticDType">
|
|
598
|
+
<xs:annotation>
|
|
599
|
+
<xs:documentation>Domestic socket type D (mainly used in India).</xs:documentation>
|
|
600
|
+
</xs:annotation>
|
|
601
|
+
</xs:enumeration>
|
|
602
|
+
<xs:enumeration value="domesticEType">
|
|
603
|
+
<xs:annotation>
|
|
604
|
+
<xs:documentation>Domestic socket type E (primarily used in France, Belgium, Poland, Slovakia & Czechia).</xs:documentation>
|
|
605
|
+
</xs:annotation>
|
|
606
|
+
</xs:enumeration>
|
|
607
|
+
<xs:enumeration value="domesticFType">
|
|
608
|
+
<xs:annotation>
|
|
609
|
+
<xs:documentation>Domestic socket type F (used almost everywhere in Europe & Russia, except for the UK & Ireland).</xs:documentation>
|
|
610
|
+
</xs:annotation>
|
|
611
|
+
</xs:enumeration>
|
|
612
|
+
<xs:enumeration value="domesticGType">
|
|
613
|
+
<xs:annotation>
|
|
614
|
+
<xs:documentation>Domestic socket type G (mainly used in the United Kingdom, Ireland, Malta, Malaysia, Singapore & the Arabian Peninsula).</xs:documentation>
|
|
615
|
+
</xs:annotation>
|
|
616
|
+
</xs:enumeration>
|
|
617
|
+
<xs:enumeration value="domesticHType">
|
|
618
|
+
<xs:annotation>
|
|
619
|
+
<xs:documentation>Domestic socket type H (used exclusively in Israel, the West Bank & the Gaza Strip).</xs:documentation>
|
|
620
|
+
</xs:annotation>
|
|
621
|
+
</xs:enumeration>
|
|
622
|
+
<xs:enumeration value="domesticIType">
|
|
623
|
+
<xs:annotation>
|
|
624
|
+
<xs:documentation>Domestic socket type I (mainly used in Australia, New Zealand, China & Argentina).</xs:documentation>
|
|
625
|
+
</xs:annotation>
|
|
626
|
+
</xs:enumeration>
|
|
627
|
+
<xs:enumeration value="domesticJType">
|
|
628
|
+
<xs:annotation>
|
|
629
|
+
<xs:documentation>Domestic socket type J (used almost exclusively in Switzerland & Liechtenstein).</xs:documentation>
|
|
630
|
+
</xs:annotation>
|
|
631
|
+
</xs:enumeration>
|
|
632
|
+
<xs:enumeration value="domesticKType">
|
|
633
|
+
<xs:annotation>
|
|
634
|
+
<xs:documentation>Domestic socket type K (used almost exclusively in Denmark & Greenland).</xs:documentation>
|
|
635
|
+
</xs:annotation>
|
|
636
|
+
</xs:enumeration>
|
|
637
|
+
<xs:enumeration value="domesticLType">
|
|
638
|
+
<xs:annotation>
|
|
639
|
+
<xs:documentation>Domestic socket type L (used almost exclusively in Italy & Chile).</xs:documentation>
|
|
640
|
+
</xs:annotation>
|
|
641
|
+
</xs:enumeration>
|
|
642
|
+
<xs:enumeration value="domesticMType">
|
|
643
|
+
<xs:annotation>
|
|
644
|
+
<xs:documentation>Domestic socket type M (mainly used in South Africa).</xs:documentation>
|
|
645
|
+
</xs:annotation>
|
|
646
|
+
</xs:enumeration>
|
|
647
|
+
<xs:enumeration value="domesticNType">
|
|
648
|
+
<xs:annotation>
|
|
649
|
+
<xs:documentation>Domestic socket type N (used in Brazil and South Africa).</xs:documentation>
|
|
650
|
+
</xs:annotation>
|
|
651
|
+
</xs:enumeration>
|
|
652
|
+
<xs:enumeration value="domesticOType">
|
|
653
|
+
<xs:annotation>
|
|
654
|
+
<xs:documentation>Domestic socket type O (used exclusively in Thailand).</xs:documentation>
|
|
655
|
+
</xs:annotation>
|
|
656
|
+
</xs:enumeration>
|
|
657
|
+
<xs:enumeration value="iec60309x2single16">
|
|
658
|
+
<xs:annotation>
|
|
659
|
+
<xs:documentation> IEC 60309-2 Industrial Connector single phase 16 amperes (usually blue).</xs:documentation>
|
|
660
|
+
</xs:annotation>
|
|
661
|
+
</xs:enumeration>
|
|
662
|
+
<xs:enumeration value="iec60309x2three16">
|
|
663
|
+
<xs:annotation>
|
|
664
|
+
<xs:documentation>IEC 60309-2 Industrial Connector three phase 16 amperes (usually red).</xs:documentation>
|
|
665
|
+
</xs:annotation>
|
|
666
|
+
</xs:enumeration>
|
|
667
|
+
<xs:enumeration value="iec60309x2three32">
|
|
668
|
+
<xs:annotation>
|
|
669
|
+
<xs:documentation>IEC 60309-2 Industrial Connector three phase 32 amperes (usually red).</xs:documentation>
|
|
670
|
+
</xs:annotation>
|
|
671
|
+
</xs:enumeration>
|
|
672
|
+
<xs:enumeration value="iec60309x2three64">
|
|
673
|
+
<xs:annotation>
|
|
674
|
+
<xs:documentation>IEC 60309-2 Industrial Connector three phase 64 amperes (usually red).</xs:documentation>
|
|
675
|
+
</xs:annotation>
|
|
676
|
+
</xs:enumeration>
|
|
677
|
+
<xs:enumeration value="iec62196T1">
|
|
678
|
+
<xs:annotation>
|
|
679
|
+
<xs:documentation>IEC 62196 Type 1 "SAE J1772". Mostly used in USA and Asia.</xs:documentation>
|
|
680
|
+
</xs:annotation>
|
|
681
|
+
</xs:enumeration>
|
|
682
|
+
<xs:enumeration value="iec62196T1COMBO">
|
|
683
|
+
<xs:annotation>
|
|
684
|
+
<xs:documentation>Combo Type 1 based, DC.</xs:documentation>
|
|
685
|
+
</xs:annotation>
|
|
686
|
+
</xs:enumeration>
|
|
687
|
+
<xs:enumeration value="iec62196T2">
|
|
688
|
+
<xs:annotation>
|
|
689
|
+
<xs:documentation>IEC 62196 Type 2 "Mennekes" - 400 V, 16-63 A. Mandatory in Europe; EN 17186 identifier "C".</xs:documentation>
|
|
690
|
+
</xs:annotation>
|
|
691
|
+
</xs:enumeration>
|
|
692
|
+
<xs:enumeration value="iec62196T2COMBO">
|
|
693
|
+
<xs:annotation>
|
|
694
|
+
<xs:documentation>Combo Type 2 based, DC, Type 2 connector with extension for simultaneous DC-charging.</xs:documentation>
|
|
695
|
+
</xs:annotation>
|
|
696
|
+
</xs:enumeration>
|
|
697
|
+
<xs:enumeration value="iec62196T3A">
|
|
698
|
+
<xs:annotation>
|
|
699
|
+
<xs:documentation>IEC 62196 Type 3A; EN 17186 identifier "D".</xs:documentation>
|
|
700
|
+
</xs:annotation>
|
|
701
|
+
</xs:enumeration>
|
|
702
|
+
<xs:enumeration value="iec62196T3C">
|
|
703
|
+
<xs:annotation>
|
|
704
|
+
<xs:documentation> IEC 62196 Type 3C "Scame"; EN 17186 identifier "E".</xs:documentation>
|
|
705
|
+
</xs:annotation>
|
|
706
|
+
</xs:enumeration>
|
|
707
|
+
<xs:enumeration value="mcs">
|
|
708
|
+
<xs:annotation>
|
|
709
|
+
<xs:documentation>MCS</xs:documentation>
|
|
710
|
+
</xs:annotation>
|
|
711
|
+
</xs:enumeration>
|
|
712
|
+
<xs:enumeration value="pantographBottomUp">
|
|
713
|
+
<xs:annotation>
|
|
714
|
+
<xs:documentation>On-board Bottom-up-Pantograph typically for bus charging.</xs:documentation>
|
|
715
|
+
</xs:annotation>
|
|
716
|
+
</xs:enumeration>
|
|
717
|
+
<xs:enumeration value="pantographTopDown">
|
|
718
|
+
<xs:annotation>
|
|
719
|
+
<xs:documentation>Off-board Top-down-Pantograph typically for bus charging.</xs:documentation>
|
|
720
|
+
</xs:annotation>
|
|
721
|
+
</xs:enumeration>
|
|
722
|
+
<xs:enumeration value="teslaConnectorEurope">
|
|
723
|
+
<xs:annotation>
|
|
724
|
+
<xs:documentation>Tesla Connector EU (modification of the Type 2 connector).</xs:documentation>
|
|
725
|
+
</xs:annotation>
|
|
726
|
+
</xs:enumeration>
|
|
727
|
+
<xs:enumeration value="teslaConnectorAmerica">
|
|
728
|
+
<xs:annotation>
|
|
729
|
+
<xs:documentation>Tesla connector used in America (Tesla specific).</xs:documentation>
|
|
730
|
+
</xs:annotation>
|
|
731
|
+
</xs:enumeration>
|
|
732
|
+
<xs:enumeration value="teslaR">
|
|
733
|
+
<xs:annotation>
|
|
734
|
+
<xs:documentation>Tesla Connector "Roadster"-type (round, 4 pin).</xs:documentation>
|
|
735
|
+
</xs:annotation>
|
|
736
|
+
</xs:enumeration>
|
|
737
|
+
<xs:enumeration value="teslaS">
|
|
738
|
+
<xs:annotation>
|
|
739
|
+
<xs:documentation>Tesla Connector "Model-S"-type (oval, 5 pin).</xs:documentation>
|
|
740
|
+
</xs:annotation>
|
|
741
|
+
</xs:enumeration>
|
|
742
|
+
<xs:enumeration value="other">
|
|
743
|
+
<xs:annotation>
|
|
744
|
+
<xs:documentation>Other charging interface.</xs:documentation>
|
|
745
|
+
</xs:annotation>
|
|
746
|
+
</xs:enumeration>
|
|
747
|
+
<xs:enumeration value="_extended" />
|
|
748
|
+
</xs:restriction>
|
|
749
|
+
</xs:simpleType>
|
|
750
|
+
<xs:simpleType name="CurrentTypeEnum">
|
|
751
|
+
<xs:annotation>
|
|
752
|
+
<xs:documentation>The type of current (AC/DC).</xs:documentation>
|
|
753
|
+
</xs:annotation>
|
|
754
|
+
<xs:restriction base="xs:string">
|
|
755
|
+
<xs:enumeration value="ac">
|
|
756
|
+
<xs:annotation>
|
|
757
|
+
<xs:documentation>Alternating current.</xs:documentation>
|
|
758
|
+
</xs:annotation>
|
|
759
|
+
</xs:enumeration>
|
|
760
|
+
<xs:enumeration value="dc">
|
|
761
|
+
<xs:annotation>
|
|
762
|
+
<xs:documentation>Direct current.</xs:documentation>
|
|
763
|
+
</xs:annotation>
|
|
764
|
+
</xs:enumeration>
|
|
765
|
+
<xs:enumeration value="_extended" />
|
|
766
|
+
</xs:restriction>
|
|
767
|
+
</xs:simpleType>
|
|
768
|
+
<xs:simpleType name="DeliveryUnitEnum">
|
|
769
|
+
<xs:annotation>
|
|
770
|
+
<xs:documentation>Table with diffrent units in which the delivery is measured.</xs:documentation>
|
|
771
|
+
</xs:annotation>
|
|
772
|
+
<xs:restriction base="xs:string">
|
|
773
|
+
<xs:enumeration value="litre">
|
|
774
|
+
<xs:annotation>
|
|
775
|
+
<xs:documentation>Litre</xs:documentation>
|
|
776
|
+
</xs:annotation>
|
|
777
|
+
</xs:enumeration>
|
|
778
|
+
<xs:enumeration value="kWh">
|
|
779
|
+
<xs:annotation>
|
|
780
|
+
<xs:documentation>Kilowatt hour.</xs:documentation>
|
|
781
|
+
</xs:annotation>
|
|
782
|
+
</xs:enumeration>
|
|
783
|
+
<xs:enumeration value="kg">
|
|
784
|
+
<xs:annotation>
|
|
785
|
+
<xs:documentation>Kilogram</xs:documentation>
|
|
786
|
+
</xs:annotation>
|
|
787
|
+
</xs:enumeration>
|
|
788
|
+
<xs:enumeration value="m3">
|
|
789
|
+
<xs:annotation>
|
|
790
|
+
<xs:documentation>Cubic metre.</xs:documentation>
|
|
791
|
+
</xs:annotation>
|
|
792
|
+
</xs:enumeration>
|
|
793
|
+
<xs:enumeration value="imperialGallon">
|
|
794
|
+
<xs:annotation>
|
|
795
|
+
<xs:documentation>Imperial gallon (4.54609 litres).</xs:documentation>
|
|
796
|
+
</xs:annotation>
|
|
797
|
+
</xs:enumeration>
|
|
798
|
+
<xs:enumeration value="usGallon">
|
|
799
|
+
<xs:annotation>
|
|
800
|
+
<xs:documentation>US gallon (3.785411784 litres).</xs:documentation>
|
|
801
|
+
</xs:annotation>
|
|
802
|
+
</xs:enumeration>
|
|
803
|
+
<xs:enumeration value="gasGallonEquivalent">
|
|
804
|
+
<xs:annotation>
|
|
805
|
+
<xs:documentation>The amount of alternative fuel it takes to equal the energy content of one liquid gallon of gasoline. Used mostly in the US.</xs:documentation>
|
|
806
|
+
</xs:annotation>
|
|
807
|
+
</xs:enumeration>
|
|
808
|
+
<xs:enumeration value="_extended" />
|
|
809
|
+
</xs:restriction>
|
|
810
|
+
</xs:simpleType>
|
|
811
|
+
<xs:complexType name="DieselRefillPoint">
|
|
812
|
+
<xs:annotation>
|
|
813
|
+
<xs:documentation>A refill point for diesel.</xs:documentation>
|
|
814
|
+
</xs:annotation>
|
|
815
|
+
<xs:complexContent>
|
|
816
|
+
<xs:extension base="aegi:RefillPoint">
|
|
817
|
+
<xs:sequence>
|
|
818
|
+
<xs:element name="dieselVehicleType" type="aegi:_DieselVehicleTypeEnum" minOccurs="0" maxOccurs="1">
|
|
819
|
+
<xs:annotation>
|
|
820
|
+
<xs:documentation>Specifies the type of diesel in terms of the applicable vehicle type.</xs:documentation>
|
|
821
|
+
</xs:annotation>
|
|
822
|
+
</xs:element>
|
|
823
|
+
<xs:element name="cetane" type="com:NonNegativeInteger" minOccurs="0" maxOccurs="1">
|
|
824
|
+
<xs:annotation>
|
|
825
|
+
<xs:documentation>Diesel's cetane value.</xs:documentation>
|
|
826
|
+
</xs:annotation>
|
|
827
|
+
</xs:element>
|
|
828
|
+
<xs:element name="bioDieselShare" type="com:Percentage" minOccurs="0" maxOccurs="1">
|
|
829
|
+
<xs:annotation>
|
|
830
|
+
<xs:documentation>Share of vegetable oil or animal fat-based diesel fuel.</xs:documentation>
|
|
831
|
+
</xs:annotation>
|
|
832
|
+
</xs:element>
|
|
833
|
+
<xs:element name="_dieselRefillPointExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
834
|
+
</xs:sequence>
|
|
835
|
+
</xs:extension>
|
|
836
|
+
</xs:complexContent>
|
|
837
|
+
</xs:complexType>
|
|
838
|
+
<xs:simpleType name="DieselVehicleTypeEnum">
|
|
839
|
+
<xs:annotation>
|
|
840
|
+
<xs:documentation>Car or truck diesel.</xs:documentation>
|
|
841
|
+
</xs:annotation>
|
|
842
|
+
<xs:restriction base="xs:string">
|
|
843
|
+
<xs:enumeration value="carDiesel">
|
|
844
|
+
<xs:annotation>
|
|
845
|
+
<xs:documentation>Diesel for cars.</xs:documentation>
|
|
846
|
+
</xs:annotation>
|
|
847
|
+
</xs:enumeration>
|
|
848
|
+
<xs:enumeration value="truckDiesel">
|
|
849
|
+
<xs:annotation>
|
|
850
|
+
<xs:documentation>Diesel for trucks.</xs:documentation>
|
|
851
|
+
</xs:annotation>
|
|
852
|
+
</xs:enumeration>
|
|
853
|
+
<xs:enumeration value="_extended" />
|
|
854
|
+
</xs:restriction>
|
|
855
|
+
</xs:simpleType>
|
|
856
|
+
<xs:complexType name="ElectricChargingPoint">
|
|
857
|
+
<xs:annotation>
|
|
858
|
+
<xs:documentation>Technical infrastructure at a specific location that facilitates electric charging of one vehicle at a time.</xs:documentation>
|
|
859
|
+
</xs:annotation>
|
|
860
|
+
<xs:complexContent>
|
|
861
|
+
<xs:extension base="aegi:RefillPoint">
|
|
862
|
+
<xs:sequence>
|
|
863
|
+
<xs:element name="currentType" type="aegi:_CurrentTypeEnum" minOccurs="1" maxOccurs="1">
|
|
864
|
+
<xs:annotation>
|
|
865
|
+
<xs:documentation>The type of current (AC/DC).</xs:documentation>
|
|
866
|
+
</xs:annotation>
|
|
867
|
+
</xs:element>
|
|
868
|
+
<xs:element name="usageType" type="aegi:_ChargingPointUsageTypeEnum" minOccurs="0" maxOccurs="unbounded">
|
|
869
|
+
<xs:annotation>
|
|
870
|
+
<xs:documentation>Usage type of the electric charging point.</xs:documentation>
|
|
871
|
+
</xs:annotation>
|
|
872
|
+
</xs:element>
|
|
873
|
+
<xs:element name="vehicleToGridCommunicationType" type="aegi:_VehicleToGridCommunicationTypeEnum" minOccurs="0" maxOccurs="unbounded">
|
|
874
|
+
<xs:annotation>
|
|
875
|
+
<xs:documentation>Type of vehicle to grid communication used.</xs:documentation>
|
|
876
|
+
</xs:annotation>
|
|
877
|
+
</xs:element>
|
|
878
|
+
<xs:element name="numberOfConnectors" type="com:NonNegativeInteger" minOccurs="0" maxOccurs="1">
|
|
879
|
+
<xs:annotation>
|
|
880
|
+
<xs:documentation>Information on the numberof connectors at this charging point.</xs:documentation>
|
|
881
|
+
</xs:annotation>
|
|
882
|
+
</xs:element>
|
|
883
|
+
<xs:element name="availableVoltage" type="aegi:Volt" minOccurs="0" maxOccurs="unbounded">
|
|
884
|
+
<xs:annotation>
|
|
885
|
+
<xs:documentation>Possible degrees of voltage.</xs:documentation>
|
|
886
|
+
</xs:annotation>
|
|
887
|
+
</xs:element>
|
|
888
|
+
<xs:element name="availableChargingPower" type="aegi:Watt" minOccurs="0" maxOccurs="unbounded">
|
|
889
|
+
<xs:annotation>
|
|
890
|
+
<xs:documentation>Possible degrees of charging power in watts.</xs:documentation>
|
|
891
|
+
</xs:annotation>
|
|
892
|
+
</xs:element>
|
|
893
|
+
<xs:element name="chargingMode" type="aegi:_ChargingModeEnum" minOccurs="0" maxOccurs="1">
|
|
894
|
+
<xs:annotation>
|
|
895
|
+
<xs:documentation>Available charging mode.</xs:documentation>
|
|
896
|
+
</xs:annotation>
|
|
897
|
+
</xs:element>
|
|
898
|
+
<xs:element name="smartRechargingServices" type="aegi:_SmartRechargingServicesEnum" minOccurs="0" maxOccurs="unbounded">
|
|
899
|
+
<xs:annotation>
|
|
900
|
+
<xs:documentation>Smart recharging services that are available.</xs:documentation>
|
|
901
|
+
</xs:annotation>
|
|
902
|
+
</xs:element>
|
|
903
|
+
<xs:element name="otherSmartRechargingServices" type="com:MultilingualString" minOccurs="0" maxOccurs="unbounded">
|
|
904
|
+
<xs:annotation>
|
|
905
|
+
<xs:documentation>Other smart recharging services that are available.</xs:documentation>
|
|
906
|
+
</xs:annotation>
|
|
907
|
+
</xs:element>
|
|
908
|
+
<xs:element name="connector" type="aegi:Connector" minOccurs="0" maxOccurs="unbounded">
|
|
909
|
+
<xs:annotation>
|
|
910
|
+
<xs:documentation>Specify the connector(s).</xs:documentation>
|
|
911
|
+
</xs:annotation>
|
|
912
|
+
</xs:element>
|
|
913
|
+
<xs:element name="_electricChargingPointExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
914
|
+
</xs:sequence>
|
|
915
|
+
</xs:extension>
|
|
916
|
+
</xs:complexContent>
|
|
917
|
+
</xs:complexType>
|
|
918
|
+
<xs:complexType name="ElectricChargingPointStatus">
|
|
919
|
+
<xs:annotation>
|
|
920
|
+
<xs:documentation>Dynamic information on the status of the charging point.</xs:documentation>
|
|
921
|
+
</xs:annotation>
|
|
922
|
+
<xs:complexContent>
|
|
923
|
+
<xs:extension base="aegi:RefillPointStatus">
|
|
924
|
+
<xs:sequence>
|
|
925
|
+
<xs:element name="remainingChargingTime" type="com:Seconds" minOccurs="0" maxOccurs="1">
|
|
926
|
+
<xs:annotation>
|
|
927
|
+
<xs:documentation>If known, the approximate remaining charging time for the current vehicle on this refill point can be specified.</xs:documentation>
|
|
928
|
+
</xs:annotation>
|
|
929
|
+
</xs:element>
|
|
930
|
+
<xs:element name="currentVoltage" type="aegi:Volt" minOccurs="0" maxOccurs="1">
|
|
931
|
+
<xs:annotation>
|
|
932
|
+
<xs:documentation>Currently used voltage.</xs:documentation>
|
|
933
|
+
</xs:annotation>
|
|
934
|
+
</xs:element>
|
|
935
|
+
<xs:element name="currentChargingPower" type="aegi:Watt" minOccurs="0" maxOccurs="1">
|
|
936
|
+
<xs:annotation>
|
|
937
|
+
<xs:documentation>The current power in watts.</xs:documentation>
|
|
938
|
+
</xs:annotation>
|
|
939
|
+
</xs:element>
|
|
940
|
+
<xs:element name="nextAvailableChargingSlots" type="com:DateTime" minOccurs="0" maxOccurs="unbounded">
|
|
941
|
+
<xs:annotation>
|
|
942
|
+
<xs:documentation>One or more points of time in the future, at which the charging point will be available (not occupied and not reserved).</xs:documentation>
|
|
943
|
+
</xs:annotation>
|
|
944
|
+
</xs:element>
|
|
945
|
+
<xs:element name="_electricChargingPointStatusExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
946
|
+
</xs:sequence>
|
|
947
|
+
</xs:extension>
|
|
948
|
+
</xs:complexContent>
|
|
949
|
+
</xs:complexType>
|
|
950
|
+
<xs:complexType name="ElectricEnergy">
|
|
951
|
+
<xs:annotation>
|
|
952
|
+
<xs:documentation>An electric energy product that is offered,optional described with its electrical mix and its rates.</xs:documentation>
|
|
953
|
+
</xs:annotation>
|
|
954
|
+
<xs:complexContent>
|
|
955
|
+
<xs:extension base="aegi:EnergyProduct">
|
|
956
|
+
<xs:sequence>
|
|
957
|
+
<xs:element name="carbonDioxideImpact" type="aegi:GramsPerKilowattHour" minOccurs="0" maxOccurs="1">
|
|
958
|
+
<xs:annotation>
|
|
959
|
+
<xs:documentation>Exhausted carbon dioxide in grams per kilowatt hour.</xs:documentation>
|
|
960
|
+
</xs:annotation>
|
|
961
|
+
</xs:element>
|
|
962
|
+
<xs:element name="nuclearWasteImpact" type="aegi:GramsPerKilowattHour" minOccurs="0" maxOccurs="1">
|
|
963
|
+
<xs:annotation>
|
|
964
|
+
<xs:documentation>Produced nuclear waste in grams per kilowatt hour.</xs:documentation>
|
|
965
|
+
</xs:annotation>
|
|
966
|
+
</xs:element>
|
|
967
|
+
<xs:element name="electricEnergySourceRatio" type="aegi:ElectricEnergySourceRatio" minOccurs="0" maxOccurs="unbounded" />
|
|
968
|
+
<xs:element name="_electricEnergyExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
969
|
+
</xs:sequence>
|
|
970
|
+
</xs:extension>
|
|
971
|
+
</xs:complexContent>
|
|
972
|
+
</xs:complexType>
|
|
973
|
+
<xs:complexType name="ElectricEnergySourceRatio">
|
|
974
|
+
<xs:annotation>
|
|
975
|
+
<xs:documentation>Ratio for the specified energy source.</xs:documentation>
|
|
976
|
+
</xs:annotation>
|
|
977
|
+
<xs:sequence>
|
|
978
|
+
<xs:element name="energySource" type="aegi:_ElectricEnergySourceTypeEnum" minOccurs="1" maxOccurs="1">
|
|
979
|
+
<xs:annotation>
|
|
980
|
+
<xs:documentation>An electric energy source.</xs:documentation>
|
|
981
|
+
</xs:annotation>
|
|
982
|
+
</xs:element>
|
|
983
|
+
<xs:element name="otherEnergySource" type="com:String" minOccurs="0" maxOccurs="1">
|
|
984
|
+
<xs:annotation>
|
|
985
|
+
<xs:documentation>Some other energy source.</xs:documentation>
|
|
986
|
+
</xs:annotation>
|
|
987
|
+
</xs:element>
|
|
988
|
+
<xs:element name="sourceRatioValue" type="com:PercentageValue">
|
|
989
|
+
<xs:annotation>
|
|
990
|
+
<xs:documentation>The percentage ratio value of this energy source.</xs:documentation>
|
|
991
|
+
</xs:annotation>
|
|
992
|
+
</xs:element>
|
|
993
|
+
<xs:element name="_electricEnergySourceRatioExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
994
|
+
</xs:sequence>
|
|
995
|
+
</xs:complexType>
|
|
996
|
+
<xs:simpleType name="ElectricEnergySourceTypeEnum">
|
|
997
|
+
<xs:annotation>
|
|
998
|
+
<xs:documentation>Electric energy sources.</xs:documentation>
|
|
999
|
+
</xs:annotation>
|
|
1000
|
+
<xs:restriction base="xs:string">
|
|
1001
|
+
<xs:enumeration value="biogas">
|
|
1002
|
+
<xs:annotation>
|
|
1003
|
+
<xs:documentation>Biogas energy source.</xs:documentation>
|
|
1004
|
+
</xs:annotation>
|
|
1005
|
+
</xs:enumeration>
|
|
1006
|
+
<xs:enumeration value="coal">
|
|
1007
|
+
<xs:annotation>
|
|
1008
|
+
<xs:documentation>Coal energy source.</xs:documentation>
|
|
1009
|
+
</xs:annotation>
|
|
1010
|
+
</xs:enumeration>
|
|
1011
|
+
<xs:enumeration value="gas">
|
|
1012
|
+
<xs:annotation>
|
|
1013
|
+
<xs:documentation>Gas energy source.</xs:documentation>
|
|
1014
|
+
</xs:annotation>
|
|
1015
|
+
</xs:enumeration>
|
|
1016
|
+
<xs:enumeration value="nuclear">
|
|
1017
|
+
<xs:annotation>
|
|
1018
|
+
<xs:documentation>Nuclear power sources.</xs:documentation>
|
|
1019
|
+
</xs:annotation>
|
|
1020
|
+
</xs:enumeration>
|
|
1021
|
+
<xs:enumeration value="solar">
|
|
1022
|
+
<xs:annotation>
|
|
1023
|
+
<xs:documentation>Solar energy source.</xs:documentation>
|
|
1024
|
+
</xs:annotation>
|
|
1025
|
+
</xs:enumeration>
|
|
1026
|
+
<xs:enumeration value="water">
|
|
1027
|
+
<xs:annotation>
|
|
1028
|
+
<xs:documentation>Water energy source.</xs:documentation>
|
|
1029
|
+
</xs:annotation>
|
|
1030
|
+
</xs:enumeration>
|
|
1031
|
+
<xs:enumeration value="wind">
|
|
1032
|
+
<xs:annotation>
|
|
1033
|
+
<xs:documentation>Wind energy source.</xs:documentation>
|
|
1034
|
+
</xs:annotation>
|
|
1035
|
+
</xs:enumeration>
|
|
1036
|
+
<xs:enumeration value="generalGreen">
|
|
1037
|
+
<xs:annotation>
|
|
1038
|
+
<xs:documentation>All kinds of green energy sources.</xs:documentation>
|
|
1039
|
+
</xs:annotation>
|
|
1040
|
+
</xs:enumeration>
|
|
1041
|
+
<xs:enumeration value="generalFossil">
|
|
1042
|
+
<xs:annotation>
|
|
1043
|
+
<xs:documentation>All kinds of fossil power sources.</xs:documentation>
|
|
1044
|
+
</xs:annotation>
|
|
1045
|
+
</xs:enumeration>
|
|
1046
|
+
<xs:enumeration value="other">
|
|
1047
|
+
<xs:annotation>
|
|
1048
|
+
<xs:documentation>Any other energy source.</xs:documentation>
|
|
1049
|
+
</xs:annotation>
|
|
1050
|
+
</xs:enumeration>
|
|
1051
|
+
<xs:enumeration value="_extended" />
|
|
1052
|
+
</xs:restriction>
|
|
1053
|
+
</xs:simpleType>
|
|
1054
|
+
<xs:complexType name="EnergyBasedApplicability">
|
|
1055
|
+
<xs:annotation>
|
|
1056
|
+
<xs:documentation>Price is only valid within the given charging boundaries in kWh.</xs:documentation>
|
|
1057
|
+
</xs:annotation>
|
|
1058
|
+
<xs:sequence>
|
|
1059
|
+
<xs:element name="fromKWh" type="com:NonNegativeInteger" minOccurs="0" maxOccurs="1">
|
|
1060
|
+
<xs:annotation>
|
|
1061
|
+
<xs:documentation>Price is valid from the given amount of kWh.</xs:documentation>
|
|
1062
|
+
</xs:annotation>
|
|
1063
|
+
</xs:element>
|
|
1064
|
+
<xs:element name="toKWh" type="com:NonNegativeInteger" minOccurs="0" maxOccurs="1">
|
|
1065
|
+
<xs:annotation>
|
|
1066
|
+
<xs:documentation>Price is valid up to the given amount of kWh.</xs:documentation>
|
|
1067
|
+
</xs:annotation>
|
|
1068
|
+
</xs:element>
|
|
1069
|
+
<xs:element name="_energyBasedApplicabilityExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1070
|
+
</xs:sequence>
|
|
1071
|
+
</xs:complexType>
|
|
1072
|
+
<xs:complexType name="EnergyInfrastructureSite">
|
|
1073
|
+
<xs:annotation>
|
|
1074
|
+
<xs:documentation>A site where vehicles can be supplied with energy,including all buildings,stations,parking spaces and other associated services.</xs:documentation>
|
|
1075
|
+
</xs:annotation>
|
|
1076
|
+
<xs:complexContent>
|
|
1077
|
+
<xs:extension base="afac:Facility">
|
|
1078
|
+
<xs:sequence>
|
|
1079
|
+
<xs:element name="typeOfSite" type="aegi:_EnergyInfrastructureSiteTypeEnum" minOccurs="0" maxOccurs="1">
|
|
1080
|
+
<xs:annotation>
|
|
1081
|
+
<xs:documentation>Specifies the type of the site.</xs:documentation>
|
|
1082
|
+
</xs:annotation>
|
|
1083
|
+
</xs:element>
|
|
1084
|
+
<xs:element name="brand" type="com:MultilingualString" minOccurs="0" maxOccurs="1">
|
|
1085
|
+
<xs:annotation>
|
|
1086
|
+
<xs:documentation>The brand of the site.</xs:documentation>
|
|
1087
|
+
</xs:annotation>
|
|
1088
|
+
</xs:element>
|
|
1089
|
+
<xs:element name="exclusiveUsers" type="afac:_UserTypeEnum" minOccurs="0" maxOccurs="unbounded">
|
|
1090
|
+
<xs:annotation>
|
|
1091
|
+
<xs:documentation>Limitation to a set of users (exclusive).</xs:documentation>
|
|
1092
|
+
</xs:annotation>
|
|
1093
|
+
</xs:element>
|
|
1094
|
+
<xs:element name="preferredUsers" type="afac:_UserTypeEnum" minOccurs="0" maxOccurs="unbounded">
|
|
1095
|
+
<xs:annotation>
|
|
1096
|
+
<xs:documentation>Users that are preferred at this site (but not exclusive).</xs:documentation>
|
|
1097
|
+
</xs:annotation>
|
|
1098
|
+
</xs:element>
|
|
1099
|
+
<xs:element name="serviceType" type="aegi:ServiceType" minOccurs="0" maxOccurs="unbounded">
|
|
1100
|
+
<xs:annotation>
|
|
1101
|
+
<xs:documentation>Specify the type of service available at a EnergyInfrastructureSite</xs:documentation>
|
|
1102
|
+
</xs:annotation>
|
|
1103
|
+
</xs:element>
|
|
1104
|
+
<xs:element name="entrance" type="loc:Location" minOccurs="0" maxOccurs="unbounded">
|
|
1105
|
+
<xs:annotation>
|
|
1106
|
+
<xs:documentation>Possibility to specify the location of the site's entrance.</xs:documentation>
|
|
1107
|
+
</xs:annotation>
|
|
1108
|
+
</xs:element>
|
|
1109
|
+
<xs:element name="exit" type="loc:Location" minOccurs="0" maxOccurs="unbounded">
|
|
1110
|
+
<xs:annotation>
|
|
1111
|
+
<xs:documentation>Possibility to specify the location of the site's exit.</xs:documentation>
|
|
1112
|
+
</xs:annotation>
|
|
1113
|
+
</xs:element>
|
|
1114
|
+
<xs:element name="energyInfrastructureStation" type="aegi:EnergyInfrastructureStation" minOccurs="0" maxOccurs="unbounded">
|
|
1115
|
+
<xs:annotation>
|
|
1116
|
+
<xs:documentation>Specifications of charging stations on the site.</xs:documentation>
|
|
1117
|
+
</xs:annotation>
|
|
1118
|
+
</xs:element>
|
|
1119
|
+
<xs:element name="energyDistributor" type="afac:Organisation" minOccurs="0">
|
|
1120
|
+
<xs:annotation>
|
|
1121
|
+
<xs:documentation>The distributor of the energy. Valid for all attached EnergyInfrastructureStations.</xs:documentation>
|
|
1122
|
+
</xs:annotation>
|
|
1123
|
+
</xs:element>
|
|
1124
|
+
<xs:element name="mobilityServiceProvider" type="afac:Organisation" minOccurs="0" maxOccurs="unbounded">
|
|
1125
|
+
<xs:annotation>
|
|
1126
|
+
<xs:documentation>Mobility service providers offering contract-based recharging. Valid for all attached EnergyInfrastructureStations.</xs:documentation>
|
|
1127
|
+
</xs:annotation>
|
|
1128
|
+
</xs:element>
|
|
1129
|
+
<xs:element name="roamingPlatform" type="afac:Organisation" minOccurs="0" maxOccurs="unbounded">
|
|
1130
|
+
<xs:annotation>
|
|
1131
|
+
<xs:documentation>Supported roaming platforms. Valid for all attached EnergyInfrastructureStations.</xs:documentation>
|
|
1132
|
+
</xs:annotation>
|
|
1133
|
+
</xs:element>
|
|
1134
|
+
<xs:element name="_energyInfrastructureSiteExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1135
|
+
</xs:sequence>
|
|
1136
|
+
</xs:extension>
|
|
1137
|
+
</xs:complexContent>
|
|
1138
|
+
</xs:complexType>
|
|
1139
|
+
<xs:complexType name="EnergyInfrastructureSiteStatus">
|
|
1140
|
+
<xs:annotation>
|
|
1141
|
+
<xs:documentation>Dynamic information on the status of the energy supplying site.</xs:documentation>
|
|
1142
|
+
</xs:annotation>
|
|
1143
|
+
<xs:complexContent>
|
|
1144
|
+
<xs:extension base="afac:FacilityStatus">
|
|
1145
|
+
<xs:sequence>
|
|
1146
|
+
<xs:element name="availableCarParkingPlaces" type="com:NonNegativeInteger" minOccurs="0" maxOccurs="1">
|
|
1147
|
+
<xs:annotation>
|
|
1148
|
+
<xs:documentation>Parking places available for cars.</xs:documentation>
|
|
1149
|
+
</xs:annotation>
|
|
1150
|
+
</xs:element>
|
|
1151
|
+
<xs:element name="availableTruckParkingPlaces" type="com:NonNegativeInteger" minOccurs="0" maxOccurs="1">
|
|
1152
|
+
<xs:annotation>
|
|
1153
|
+
<xs:documentation>Parking places available for trucks.</xs:documentation>
|
|
1154
|
+
</xs:annotation>
|
|
1155
|
+
</xs:element>
|
|
1156
|
+
<xs:element name="energyInfrastructureStationStatus" type="aegi:EnergyInfrastructureStationStatus" minOccurs="0" maxOccurs="unbounded">
|
|
1157
|
+
<xs:annotation>
|
|
1158
|
+
<xs:documentation>Specify the status of a charging station with dynamic information.</xs:documentation>
|
|
1159
|
+
</xs:annotation>
|
|
1160
|
+
</xs:element>
|
|
1161
|
+
<xs:element name="serviceType" type="aegi:ServiceType" minOccurs="0" maxOccurs="unbounded">
|
|
1162
|
+
<xs:annotation>
|
|
1163
|
+
<xs:documentation>The service type for the site. If no period is given, the currently available service is meant.</xs:documentation>
|
|
1164
|
+
</xs:annotation>
|
|
1165
|
+
</xs:element>
|
|
1166
|
+
<xs:element name="_energyInfrastructureSiteStatusExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1167
|
+
</xs:sequence>
|
|
1168
|
+
</xs:extension>
|
|
1169
|
+
</xs:complexContent>
|
|
1170
|
+
</xs:complexType>
|
|
1171
|
+
<xs:simpleType name="EnergyInfrastructureSiteTypeEnum">
|
|
1172
|
+
<xs:annotation>
|
|
1173
|
+
<xs:documentation>The type of an energy infrastructure site.</xs:documentation>
|
|
1174
|
+
</xs:annotation>
|
|
1175
|
+
<xs:restriction base="xs:string">
|
|
1176
|
+
<xs:enumeration value="inBuilding">
|
|
1177
|
+
<xs:annotation>
|
|
1178
|
+
<xs:documentation>The energy infrastructure site is located inside some building for example in a car park.</xs:documentation>
|
|
1179
|
+
</xs:annotation>
|
|
1180
|
+
</xs:enumeration>
|
|
1181
|
+
<xs:enumeration value="openSpace">
|
|
1182
|
+
<xs:annotation>
|
|
1183
|
+
<xs:documentation>The energy infrastructure site is an open space, for example a parking site.</xs:documentation>
|
|
1184
|
+
</xs:annotation>
|
|
1185
|
+
</xs:enumeration>
|
|
1186
|
+
<xs:enumeration value="onstreet">
|
|
1187
|
+
<xs:annotation>
|
|
1188
|
+
<xs:documentation>The energy infrastructure site is located alongside a street, for example some singular charging stations.</xs:documentation>
|
|
1189
|
+
</xs:annotation>
|
|
1190
|
+
</xs:enumeration>
|
|
1191
|
+
<xs:enumeration value="onCompanySite">
|
|
1192
|
+
<xs:annotation>
|
|
1193
|
+
<xs:documentation>The energy infrastructure site is located on a company site.</xs:documentation>
|
|
1194
|
+
</xs:annotation>
|
|
1195
|
+
</xs:enumeration>
|
|
1196
|
+
<xs:enumeration value="other">
|
|
1197
|
+
<xs:annotation>
|
|
1198
|
+
<xs:documentation>Other types of energy infrastructure sites.</xs:documentation>
|
|
1199
|
+
</xs:annotation>
|
|
1200
|
+
</xs:enumeration>
|
|
1201
|
+
<xs:enumeration value="_extended" />
|
|
1202
|
+
</xs:restriction>
|
|
1203
|
+
</xs:simpleType>
|
|
1204
|
+
<xs:complexType name="EnergyInfrastructureStation">
|
|
1205
|
+
<xs:annotation>
|
|
1206
|
+
<xs:documentation>A collection of associated refill points (which can be of different type). An example would be a fuel dispenser that serves different types of fuel. Often the vehicle space of the station is shared between the different refill points.</xs:documentation>
|
|
1207
|
+
</xs:annotation>
|
|
1208
|
+
<xs:complexContent>
|
|
1209
|
+
<xs:extension base="afac:Facility">
|
|
1210
|
+
<xs:sequence>
|
|
1211
|
+
<xs:element name="totalMaximumPower" type="aegi:Watt" minOccurs="0" maxOccurs="1">
|
|
1212
|
+
<xs:annotation>
|
|
1213
|
+
<xs:documentation>The total maximum power of the station.</xs:documentation>
|
|
1214
|
+
</xs:annotation>
|
|
1215
|
+
</xs:element>
|
|
1216
|
+
<xs:element name="authenticationAndIdentificationMethods" type="aegi:_AuthenticationAndIdentificationEnum" minOccurs="0" maxOccurs="unbounded">
|
|
1217
|
+
<xs:annotation>
|
|
1218
|
+
<xs:documentation>Information on what methods of identification and/or authentication are accepted.</xs:documentation>
|
|
1219
|
+
</xs:annotation>
|
|
1220
|
+
</xs:element>
|
|
1221
|
+
<xs:element name="numberOfRefillPoints" type="com:NonNegativeInteger" minOccurs="0" maxOccurs="1">
|
|
1222
|
+
<xs:annotation>
|
|
1223
|
+
<xs:documentation>Number of refill points that can be used at the same time in this energy infrastructure station.</xs:documentation>
|
|
1224
|
+
</xs:annotation>
|
|
1225
|
+
</xs:element>
|
|
1226
|
+
<xs:element name="userInterfaceLanguage" type="com:Language" minOccurs="0" maxOccurs="unbounded">
|
|
1227
|
+
<xs:annotation>
|
|
1228
|
+
<xs:documentation>Languages, in which a user interface is available.</xs:documentation>
|
|
1229
|
+
</xs:annotation>
|
|
1230
|
+
</xs:element>
|
|
1231
|
+
<xs:element name="renewableSources" type="com:Boolean" minOccurs="0" maxOccurs="1">
|
|
1232
|
+
<xs:annotation>
|
|
1233
|
+
<xs:documentation>Specifies, if the energy sources (e.g. hydrogen or liquid methane) are 100 % renewable in accordance with rules established under Directive (EU) 2018/2001 and relevant secondary legislation (EU Guarantee of Origin (GO) scheme).</xs:documentation>
|
|
1234
|
+
</xs:annotation>
|
|
1235
|
+
</xs:element>
|
|
1236
|
+
<xs:element name="energyDistributor" type="afac:Organisation" minOccurs="0">
|
|
1237
|
+
<xs:annotation>
|
|
1238
|
+
<xs:documentation>The distributor of the energy.</xs:documentation>
|
|
1239
|
+
</xs:annotation>
|
|
1240
|
+
</xs:element>
|
|
1241
|
+
<xs:element name="mobilityServiceProvider" type="afac:Organisation" minOccurs="0" maxOccurs="unbounded">
|
|
1242
|
+
<xs:annotation>
|
|
1243
|
+
<xs:documentation>Mobility service providers offering contract-based recharging</xs:documentation>
|
|
1244
|
+
</xs:annotation>
|
|
1245
|
+
</xs:element>
|
|
1246
|
+
<xs:element name="roamingPlatform" type="afac:Organisation" minOccurs="0" maxOccurs="unbounded">
|
|
1247
|
+
<xs:annotation>
|
|
1248
|
+
<xs:documentation>Supported roaming platforms</xs:documentation>
|
|
1249
|
+
</xs:annotation>
|
|
1250
|
+
</xs:element>
|
|
1251
|
+
<xs:element name="hydrogen" type="aegi:Hydrogen" minOccurs="0" />
|
|
1252
|
+
<xs:element name="serviceType" type="aegi:ServiceType" minOccurs="0" maxOccurs="unbounded">
|
|
1253
|
+
<xs:annotation>
|
|
1254
|
+
<xs:documentation>Specify the type of service available at the EnergyInfrastructureStation.</xs:documentation>
|
|
1255
|
+
</xs:annotation>
|
|
1256
|
+
</xs:element>
|
|
1257
|
+
<xs:element name="refillPoint" type="aegi:RefillPoint" minOccurs="0" maxOccurs="unbounded">
|
|
1258
|
+
<xs:annotation>
|
|
1259
|
+
<xs:documentation>Specifications of refill points at a charging station. Note that the refillPointIndex must be unique within the complete site!</xs:documentation>
|
|
1260
|
+
</xs:annotation>
|
|
1261
|
+
</xs:element>
|
|
1262
|
+
<xs:element name="energyProduct" type="aegi:EnergyProduct" minOccurs="0" maxOccurs="unbounded" />
|
|
1263
|
+
<xs:element name="_energyInfrastructureStationExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1264
|
+
</xs:sequence>
|
|
1265
|
+
</xs:extension>
|
|
1266
|
+
</xs:complexContent>
|
|
1267
|
+
</xs:complexType>
|
|
1268
|
+
<xs:complexType name="EnergyInfrastructureStationStatus">
|
|
1269
|
+
<xs:annotation>
|
|
1270
|
+
<xs:documentation>Dynamic information on the status of the station.</xs:documentation>
|
|
1271
|
+
</xs:annotation>
|
|
1272
|
+
<xs:complexContent>
|
|
1273
|
+
<xs:extension base="afac:FacilityStatus">
|
|
1274
|
+
<xs:sequence>
|
|
1275
|
+
<xs:element name="isAvailable" type="com:Boolean" minOccurs="0" maxOccurs="1">
|
|
1276
|
+
<xs:annotation>
|
|
1277
|
+
<xs:documentation>Information whether the specific station is available or not. It might be unavailable for example because of a fault, damage or maintenance. It does not inform, if the corresponding refill points are currently occupied or not.</xs:documentation>
|
|
1278
|
+
</xs:annotation>
|
|
1279
|
+
</xs:element>
|
|
1280
|
+
<xs:element name="limitedHydrogenAmount" type="com:Boolean" minOccurs="0" maxOccurs="1">
|
|
1281
|
+
<xs:annotation>
|
|
1282
|
+
<xs:documentation>Indication about limited amount of hydrogen available (less than 100 kg) in the refuelling station.</xs:documentation>
|
|
1283
|
+
</xs:annotation>
|
|
1284
|
+
</xs:element>
|
|
1285
|
+
<xs:element name="refillPointStatus" type="aegi:RefillPointStatus" minOccurs="0" maxOccurs="unbounded">
|
|
1286
|
+
<xs:annotation>
|
|
1287
|
+
<xs:documentation>Specify the status of a refill point with dynamic information.</xs:documentation>
|
|
1288
|
+
</xs:annotation>
|
|
1289
|
+
</xs:element>
|
|
1290
|
+
<xs:element name="serviceType" type="aegi:ServiceType" minOccurs="0" maxOccurs="unbounded">
|
|
1291
|
+
<xs:annotation>
|
|
1292
|
+
<xs:documentation>The service type for the station. If no period is given, the currently available service is meant.</xs:documentation>
|
|
1293
|
+
</xs:annotation>
|
|
1294
|
+
</xs:element>
|
|
1295
|
+
<xs:element name="energyRateUpdate" type="aegi:EnergyRateUpdate" minOccurs="0" maxOccurs="unbounded" />
|
|
1296
|
+
<xs:element name="_energyInfrastructureStationStatusExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1297
|
+
</xs:sequence>
|
|
1298
|
+
</xs:extension>
|
|
1299
|
+
</xs:complexContent>
|
|
1300
|
+
</xs:complexType>
|
|
1301
|
+
<xs:complexType name="EnergyInfrastructureStatusPublication">
|
|
1302
|
+
<xs:annotation>
|
|
1303
|
+
<xs:documentation>Dynamic information on the status of energy supplying sites.</xs:documentation>
|
|
1304
|
+
</xs:annotation>
|
|
1305
|
+
<xs:complexContent>
|
|
1306
|
+
<xs:extension base="com:PayloadPublication">
|
|
1307
|
+
<xs:sequence>
|
|
1308
|
+
<xs:element name="tableReference" type="aegi:_EnergyInfrastructureTableVersionedReference" minOccurs="0" maxOccurs="unbounded">
|
|
1309
|
+
<xs:annotation>
|
|
1310
|
+
<xs:documentation>Reference to static tables containing the sites referenced in this publication.</xs:documentation>
|
|
1311
|
+
</xs:annotation>
|
|
1312
|
+
</xs:element>
|
|
1313
|
+
<xs:element name="headerInformation" type="com:HeaderInformation" minOccurs="0" />
|
|
1314
|
+
<xs:element name="energyInfrastructureSiteStatus" type="aegi:EnergyInfrastructureSiteStatus" minOccurs="0" maxOccurs="unbounded" />
|
|
1315
|
+
<xs:element name="_energyInfrastructureStatusPublicationExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1316
|
+
</xs:sequence>
|
|
1317
|
+
</xs:extension>
|
|
1318
|
+
</xs:complexContent>
|
|
1319
|
+
</xs:complexType>
|
|
1320
|
+
<xs:complexType name="EnergyInfrastructureTable">
|
|
1321
|
+
<xs:annotation>
|
|
1322
|
+
<xs:documentation>A table of sites where vehicles can be supplied with energy.</xs:documentation>
|
|
1323
|
+
</xs:annotation>
|
|
1324
|
+
<xs:sequence>
|
|
1325
|
+
<xs:element name="tableName" type="com:String" minOccurs="0" maxOccurs="1">
|
|
1326
|
+
<xs:annotation>
|
|
1327
|
+
<xs:documentation>The name of the Energy Infrastructure Table.</xs:documentation>
|
|
1328
|
+
</xs:annotation>
|
|
1329
|
+
</xs:element>
|
|
1330
|
+
<xs:element name="energyInfrastructureSite" type="aegi:EnergyInfrastructureSite" maxOccurs="unbounded" />
|
|
1331
|
+
<xs:element name="_energyInfrastructureTableExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1332
|
+
</xs:sequence>
|
|
1333
|
+
<xs:attribute name="id" type="xs:string" use="required" />
|
|
1334
|
+
<xs:attribute name="version" type="xs:string" use="required" />
|
|
1335
|
+
</xs:complexType>
|
|
1336
|
+
<xs:complexType name="EnergyInfrastructureTablePublication">
|
|
1337
|
+
<xs:annotation>
|
|
1338
|
+
<xs:documentation>A publication of static information on the infrastructure for vehicle energy supply.</xs:documentation>
|
|
1339
|
+
</xs:annotation>
|
|
1340
|
+
<xs:complexContent>
|
|
1341
|
+
<xs:extension base="com:PayloadPublication">
|
|
1342
|
+
<xs:sequence>
|
|
1343
|
+
<xs:element name="headerInformation" type="com:HeaderInformation" minOccurs="0" />
|
|
1344
|
+
<xs:element name="energyInfrastructureTable" type="aegi:EnergyInfrastructureTable" maxOccurs="unbounded" />
|
|
1345
|
+
<xs:element name="_energyInfrastructureTablePublicationExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1346
|
+
</xs:sequence>
|
|
1347
|
+
</xs:extension>
|
|
1348
|
+
</xs:complexContent>
|
|
1349
|
+
</xs:complexType>
|
|
1350
|
+
<xs:complexType name="EnergyPrice">
|
|
1351
|
+
<xs:annotation>
|
|
1352
|
+
<xs:documentation>A price definition for energy refueling. All prices (of a rate) with the same group index belong together (for example base price AND price per kWh). Prices with a different group index are alternative to each other (for example price per minute OR flat r</xs:documentation>
|
|
1353
|
+
</xs:annotation>
|
|
1354
|
+
<xs:sequence>
|
|
1355
|
+
<xs:element name="priceGroupIndex" type="com:NonNegativeInteger" minOccurs="1" maxOccurs="1">
|
|
1356
|
+
<xs:annotation>
|
|
1357
|
+
<xs:documentation>All prices (of a rate) with the same group index belong together (for example base price AND price per kWh). Prices with a different group index are alternative to each other (for example price per minute OR flat rate instead).</xs:documentation>
|
|
1358
|
+
</xs:annotation>
|
|
1359
|
+
</xs:element>
|
|
1360
|
+
<xs:element name="priceType" type="aegi:_PriceTypeEnum" minOccurs="1" maxOccurs="1">
|
|
1361
|
+
<xs:annotation>
|
|
1362
|
+
<xs:documentation>The type of price for the energy supply.</xs:documentation>
|
|
1363
|
+
</xs:annotation>
|
|
1364
|
+
</xs:element>
|
|
1365
|
+
<xs:element name="value" type="afac:AmountOfMoney" minOccurs="1" maxOccurs="1">
|
|
1366
|
+
<xs:annotation>
|
|
1367
|
+
<xs:documentation>The price for the energy according to the price type.</xs:documentation>
|
|
1368
|
+
</xs:annotation>
|
|
1369
|
+
</xs:element>
|
|
1370
|
+
<xs:element name="priceCap" type="afac:AmountOfMoney" minOccurs="0" maxOccurs="1">
|
|
1371
|
+
<xs:annotation>
|
|
1372
|
+
<xs:documentation>An upper cap for this price which will be charged at maximum.</xs:documentation>
|
|
1373
|
+
</xs:annotation>
|
|
1374
|
+
</xs:element>
|
|
1375
|
+
<xs:element name="taxIncluded" type="com:Boolean" minOccurs="0" maxOccurs="1">
|
|
1376
|
+
<xs:annotation>
|
|
1377
|
+
<xs:documentation>[TRUE] Indication that tax to be applied is included [FALSE] indicates that the tax is added additionally to the total.</xs:documentation>
|
|
1378
|
+
</xs:annotation>
|
|
1379
|
+
</xs:element>
|
|
1380
|
+
<xs:element name="taxRate" type="com:Percentage" minOccurs="0" maxOccurs="1">
|
|
1381
|
+
<xs:annotation>
|
|
1382
|
+
<xs:documentation>The percentage rate of tax to be applied.</xs:documentation>
|
|
1383
|
+
</xs:annotation>
|
|
1384
|
+
</xs:element>
|
|
1385
|
+
<xs:element name="additionalInformation" type="com:MultilingualString" minOccurs="0" maxOccurs="1">
|
|
1386
|
+
<xs:annotation>
|
|
1387
|
+
<xs:documentation>Free text field for additional information regarding the price.</xs:documentation>
|
|
1388
|
+
</xs:annotation>
|
|
1389
|
+
</xs:element>
|
|
1390
|
+
<xs:element name="overallPeriod" type="com:OverallPeriod" minOccurs="0" />
|
|
1391
|
+
<xs:element name="timeBasedApplicability" type="aegi:TimeBasedApplicability" minOccurs="0" />
|
|
1392
|
+
<xs:element name="energyBasedApplicability" type="aegi:EnergyBasedApplicability" minOccurs="0" />
|
|
1393
|
+
<xs:element name="_energyPriceExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1394
|
+
</xs:sequence>
|
|
1395
|
+
</xs:complexType>
|
|
1396
|
+
<xs:complexType name="EnergyProduct">
|
|
1397
|
+
<xs:annotation>
|
|
1398
|
+
<xs:documentation>Specification of an energy product that is offered. It can be applied to all types of energy sources.</xs:documentation>
|
|
1399
|
+
</xs:annotation>
|
|
1400
|
+
<xs:sequence>
|
|
1401
|
+
<xs:element name="energyProductName" type="com:MultilingualString" minOccurs="0" maxOccurs="1">
|
|
1402
|
+
<xs:annotation>
|
|
1403
|
+
<xs:documentation>A name for this energy product.</xs:documentation>
|
|
1404
|
+
</xs:annotation>
|
|
1405
|
+
</xs:element>
|
|
1406
|
+
<xs:element name="isGreenEnergy" type="com:Boolean" minOccurs="0" maxOccurs="1">
|
|
1407
|
+
<xs:annotation>
|
|
1408
|
+
<xs:documentation>True if 100% from regenerative sources (CO2 and nuclear waste is zero).</xs:documentation>
|
|
1409
|
+
</xs:annotation>
|
|
1410
|
+
</xs:element>
|
|
1411
|
+
<xs:element name="energyRateByReference" type="aegi:_EnergyRateReference" minOccurs="0" maxOccurs="unbounded">
|
|
1412
|
+
<xs:annotation>
|
|
1413
|
+
<xs:documentation>Specifies one ore more rates for this type of energy by reference to exisiting EnergyRate specification.</xs:documentation>
|
|
1414
|
+
</xs:annotation>
|
|
1415
|
+
</xs:element>
|
|
1416
|
+
<xs:element name="energyProductInformation" type="com:Url" minOccurs="0" maxOccurs="1">
|
|
1417
|
+
<xs:annotation>
|
|
1418
|
+
<xs:documentation>Further information on this energy product provided by a web link.</xs:documentation>
|
|
1419
|
+
</xs:annotation>
|
|
1420
|
+
</xs:element>
|
|
1421
|
+
<xs:element name="renewableEnergyEvidence" type="com:Url" minOccurs="0" maxOccurs="1">
|
|
1422
|
+
<xs:annotation>
|
|
1423
|
+
<xs:documentation>Proofs on the sources of renewable energy for this energy product provided by a web link.</xs:documentation>
|
|
1424
|
+
</xs:annotation>
|
|
1425
|
+
</xs:element>
|
|
1426
|
+
<xs:element name="mobilityServiceProvider" type="afac:Organisation" minOccurs="0" maxOccurs="unbounded">
|
|
1427
|
+
<xs:annotation>
|
|
1428
|
+
<xs:documentation>Mobility service providers offering contract-based recharging</xs:documentation>
|
|
1429
|
+
</xs:annotation>
|
|
1430
|
+
</xs:element>
|
|
1431
|
+
<xs:element name="energyRate" type="aegi:EnergyRate" minOccurs="0" maxOccurs="unbounded" />
|
|
1432
|
+
<xs:element name="_energyProductExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1433
|
+
</xs:sequence>
|
|
1434
|
+
</xs:complexType>
|
|
1435
|
+
<xs:complexType name="EnergyRate">
|
|
1436
|
+
<xs:annotation>
|
|
1437
|
+
<xs:documentation>A rate dedicated for the energy product.</xs:documentation>
|
|
1438
|
+
</xs:annotation>
|
|
1439
|
+
<xs:sequence>
|
|
1440
|
+
<xs:element name="ratePolicy" type="aegi:_RatePolicyEnum" minOccurs="1" maxOccurs="1">
|
|
1441
|
+
<xs:annotation>
|
|
1442
|
+
<xs:documentation>Indication if contract based or ad hoc price.</xs:documentation>
|
|
1443
|
+
</xs:annotation>
|
|
1444
|
+
</xs:element>
|
|
1445
|
+
<xs:element name="lastUpdated" type="com:DateTime" minOccurs="1" maxOccurs="1">
|
|
1446
|
+
<xs:annotation>
|
|
1447
|
+
<xs:documentation>The date/time at which this information was last updated.</xs:documentation>
|
|
1448
|
+
</xs:annotation>
|
|
1449
|
+
</xs:element>
|
|
1450
|
+
<xs:element name="applicableCurrency" type="afac:CurrencyCode" minOccurs="1" maxOccurs="unbounded">
|
|
1451
|
+
<xs:annotation>
|
|
1452
|
+
<xs:documentation>A general information on the applicable monetary currency.</xs:documentation>
|
|
1453
|
+
</xs:annotation>
|
|
1454
|
+
</xs:element>
|
|
1455
|
+
<xs:element name="rateName" type="com:MultilingualString" minOccurs="0" maxOccurs="1">
|
|
1456
|
+
<xs:annotation>
|
|
1457
|
+
<xs:documentation>A name for this rate, for example the name of the specific energy contract.</xs:documentation>
|
|
1458
|
+
</xs:annotation>
|
|
1459
|
+
</xs:element>
|
|
1460
|
+
<xs:element name="combinationWithParkingFee" type="com:Boolean" minOccurs="0" maxOccurs="1">
|
|
1461
|
+
<xs:annotation>
|
|
1462
|
+
<xs:documentation>Indicates whether vehicle charging and parking are included in one combined fee.</xs:documentation>
|
|
1463
|
+
</xs:annotation>
|
|
1464
|
+
</xs:element>
|
|
1465
|
+
<xs:element name="maximumDeliveryFee" type="afac:AmountOfMoney" minOccurs="0" maxOccurs="1">
|
|
1466
|
+
<xs:annotation>
|
|
1467
|
+
<xs:documentation>A maximum delivery fee.</xs:documentation>
|
|
1468
|
+
</xs:annotation>
|
|
1469
|
+
</xs:element>
|
|
1470
|
+
<xs:element name="minimumDeliveryFee" type="afac:AmountOfMoney" minOccurs="0" maxOccurs="1">
|
|
1471
|
+
<xs:annotation>
|
|
1472
|
+
<xs:documentation>A minimum delivery fee.</xs:documentation>
|
|
1473
|
+
</xs:annotation>
|
|
1474
|
+
</xs:element>
|
|
1475
|
+
<xs:element name="discount" type="com:Percentage" minOccurs="0" maxOccurs="1">
|
|
1476
|
+
<xs:annotation>
|
|
1477
|
+
<xs:documentation>Discount indicated in %.</xs:documentation>
|
|
1478
|
+
</xs:annotation>
|
|
1479
|
+
</xs:element>
|
|
1480
|
+
<xs:element name="additionalInformation" type="com:MultilingualString" minOccurs="0" maxOccurs="1">
|
|
1481
|
+
<xs:annotation>
|
|
1482
|
+
<xs:documentation>Free text field for additional information regarding the energy rates.</xs:documentation>
|
|
1483
|
+
</xs:annotation>
|
|
1484
|
+
</xs:element>
|
|
1485
|
+
<xs:element name="payment" type="afac:Payment" minOccurs="0" />
|
|
1486
|
+
<xs:element name="energyPrice" type="aegi:EnergyPrice" minOccurs="0" maxOccurs="unbounded" />
|
|
1487
|
+
<xs:element name="overallPeriod" type="com:OverallPeriod" minOccurs="0" />
|
|
1488
|
+
<xs:element name="_energyRateExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1489
|
+
</xs:sequence>
|
|
1490
|
+
<xs:attribute name="id" type="xs:string" use="required" />
|
|
1491
|
+
</xs:complexType>
|
|
1492
|
+
<xs:complexType name="EnergyRateUpdate">
|
|
1493
|
+
<xs:annotation>
|
|
1494
|
+
<xs:documentation>Updates a rate defined in the static part of the model.</xs:documentation>
|
|
1495
|
+
</xs:annotation>
|
|
1496
|
+
<xs:sequence>
|
|
1497
|
+
<xs:element name="lastUpdated" type="com:DateTime" minOccurs="1" maxOccurs="1">
|
|
1498
|
+
<xs:annotation>
|
|
1499
|
+
<xs:documentation>The date/time at which this information was last updated.</xs:documentation>
|
|
1500
|
+
</xs:annotation>
|
|
1501
|
+
</xs:element>
|
|
1502
|
+
<xs:element name="energyRateReference" type="aegi:_EnergyRateReference" minOccurs="1" maxOccurs="1">
|
|
1503
|
+
<xs:annotation>
|
|
1504
|
+
<xs:documentation>Specifies the EnergyRate that is updated here.</xs:documentation>
|
|
1505
|
+
</xs:annotation>
|
|
1506
|
+
</xs:element>
|
|
1507
|
+
<xs:element name="additionalInformation" type="com:MultilingualString" minOccurs="0" maxOccurs="1">
|
|
1508
|
+
<xs:annotation>
|
|
1509
|
+
<xs:documentation>Free text field for additional information regarding the energy rates.</xs:documentation>
|
|
1510
|
+
</xs:annotation>
|
|
1511
|
+
</xs:element>
|
|
1512
|
+
<xs:element name="energyPrice" type="aegi:EnergyPrice" minOccurs="0" maxOccurs="unbounded" />
|
|
1513
|
+
<xs:element name="_energyRateUpdateExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1514
|
+
</xs:sequence>
|
|
1515
|
+
</xs:complexType>
|
|
1516
|
+
<xs:simpleType name="GasConnectorTypeEnum">
|
|
1517
|
+
<xs:annotation>
|
|
1518
|
+
<xs:documentation>Available connectors that serve differen types of gas.</xs:documentation>
|
|
1519
|
+
</xs:annotation>
|
|
1520
|
+
<xs:restriction base="xs:string">
|
|
1521
|
+
<xs:enumeration value="gaseousHydrogen">
|
|
1522
|
+
<xs:annotation>
|
|
1523
|
+
<xs:documentation>Gaseous hydrogen.</xs:documentation>
|
|
1524
|
+
</xs:annotation>
|
|
1525
|
+
</xs:enumeration>
|
|
1526
|
+
<xs:enumeration value="liquidHydrogen">
|
|
1527
|
+
<xs:annotation>
|
|
1528
|
+
<xs:documentation>Liquid hydrogen.</xs:documentation>
|
|
1529
|
+
</xs:annotation>
|
|
1530
|
+
</xs:enumeration>
|
|
1531
|
+
<xs:enumeration value="cng">
|
|
1532
|
+
<xs:annotation>
|
|
1533
|
+
<xs:documentation>CNG (Compressed Natural Gas).</xs:documentation>
|
|
1534
|
+
</xs:annotation>
|
|
1535
|
+
</xs:enumeration>
|
|
1536
|
+
<xs:enumeration value="lng">
|
|
1537
|
+
<xs:annotation>
|
|
1538
|
+
<xs:documentation>LNG (Liquefied Natural Gas).</xs:documentation>
|
|
1539
|
+
</xs:annotation>
|
|
1540
|
+
</xs:enumeration>
|
|
1541
|
+
<xs:enumeration value="lpg">
|
|
1542
|
+
<xs:annotation>
|
|
1543
|
+
<xs:documentation>LPG (Liquefied Petroleum Gas).</xs:documentation>
|
|
1544
|
+
</xs:annotation>
|
|
1545
|
+
</xs:enumeration>
|
|
1546
|
+
<xs:enumeration value="biogas">
|
|
1547
|
+
<xs:annotation>
|
|
1548
|
+
<xs:documentation>A mixture of different gases produced by the breakdown of organic matter.</xs:documentation>
|
|
1549
|
+
</xs:annotation>
|
|
1550
|
+
</xs:enumeration>
|
|
1551
|
+
<xs:enumeration value="unknown">
|
|
1552
|
+
<xs:annotation>
|
|
1553
|
+
<xs:documentation>The type of gas connector is unknown.</xs:documentation>
|
|
1554
|
+
</xs:annotation>
|
|
1555
|
+
</xs:enumeration>
|
|
1556
|
+
<xs:enumeration value="_extended" />
|
|
1557
|
+
</xs:restriction>
|
|
1558
|
+
</xs:simpleType>
|
|
1559
|
+
<xs:simpleType name="GramsPerKilowattHour">
|
|
1560
|
+
<xs:annotation>
|
|
1561
|
+
<xs:documentation>Grams per kWh (e.g. for carbon dioxide impact).</xs:documentation>
|
|
1562
|
+
</xs:annotation>
|
|
1563
|
+
<xs:restriction base="com:Float" />
|
|
1564
|
+
</xs:simpleType>
|
|
1565
|
+
<xs:complexType name="Hydrogen">
|
|
1566
|
+
<xs:annotation>
|
|
1567
|
+
<xs:documentation>Information for hydrogen stations.</xs:documentation>
|
|
1568
|
+
</xs:annotation>
|
|
1569
|
+
<xs:sequence>
|
|
1570
|
+
<xs:element name="refuellingMode" type="aegi:_HydrogenRefuellingModeEnum" minOccurs="1" maxOccurs="unbounded">
|
|
1571
|
+
<xs:annotation>
|
|
1572
|
+
<xs:documentation>Definition of the available refill solutions for hydrogen.</xs:documentation>
|
|
1573
|
+
</xs:annotation>
|
|
1574
|
+
</xs:element>
|
|
1575
|
+
<xs:element name="cumulativeCapacityperDay" type="aegi:KilogramPerDay" minOccurs="1" maxOccurs="1">
|
|
1576
|
+
<xs:annotation>
|
|
1577
|
+
<xs:documentation>Indication of the cumulative capacity per day (expressed in kg/day) of a hydrogen refuelling station.</xs:documentation>
|
|
1578
|
+
</xs:annotation>
|
|
1579
|
+
</xs:element>
|
|
1580
|
+
<xs:element name="_hydrogenExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1581
|
+
</xs:sequence>
|
|
1582
|
+
</xs:complexType>
|
|
1583
|
+
<xs:simpleType name="HydrogenFuellingProcessProtocolEnum">
|
|
1584
|
+
<xs:annotation>
|
|
1585
|
+
<xs:documentation>A table with different types of protocols that are used during the hydron fuelling process.</xs:documentation>
|
|
1586
|
+
</xs:annotation>
|
|
1587
|
+
<xs:restriction base="xs:string">
|
|
1588
|
+
<xs:enumeration value="saej2601v2010">
|
|
1589
|
+
<xs:annotation>
|
|
1590
|
+
<xs:documentation>Protocol according to SAE J2601 standard, version from 2010.</xs:documentation>
|
|
1591
|
+
</xs:annotation>
|
|
1592
|
+
</xs:enumeration>
|
|
1593
|
+
<xs:enumeration value="saej2601v2014">
|
|
1594
|
+
<xs:annotation>
|
|
1595
|
+
<xs:documentation>Protocol according to SAE J2601 standard, version from 2014.</xs:documentation>
|
|
1596
|
+
</xs:annotation>
|
|
1597
|
+
</xs:enumeration>
|
|
1598
|
+
<xs:enumeration value="saej2601v2016">
|
|
1599
|
+
<xs:annotation>
|
|
1600
|
+
<xs:documentation>Protocol according to SAE J2601 standard, version from 2016.</xs:documentation>
|
|
1601
|
+
</xs:annotation>
|
|
1602
|
+
</xs:enumeration>
|
|
1603
|
+
<xs:enumeration value="mcMethod">
|
|
1604
|
+
<xs:annotation>
|
|
1605
|
+
<xs:documentation>Protocol according to the MC method.</xs:documentation>
|
|
1606
|
+
</xs:annotation>
|
|
1607
|
+
</xs:enumeration>
|
|
1608
|
+
<xs:enumeration value="unknown">
|
|
1609
|
+
<xs:annotation>
|
|
1610
|
+
<xs:documentation>The protocol is unknown.</xs:documentation>
|
|
1611
|
+
</xs:annotation>
|
|
1612
|
+
</xs:enumeration>
|
|
1613
|
+
<xs:enumeration value="_extended" />
|
|
1614
|
+
</xs:restriction>
|
|
1615
|
+
</xs:simpleType>
|
|
1616
|
+
<xs:simpleType name="HydrogenRefuellingModeEnum">
|
|
1617
|
+
<xs:annotation>
|
|
1618
|
+
<xs:documentation>A table of different refilling solutions for hydrogen.</xs:documentation>
|
|
1619
|
+
</xs:annotation>
|
|
1620
|
+
<xs:restriction base="xs:string">
|
|
1621
|
+
<xs:enumeration value="gaseousHydrogen350barCar">
|
|
1622
|
+
<xs:annotation>
|
|
1623
|
+
<xs:documentation>Gaseous hydrogen with 350 bar pressure for cars.</xs:documentation>
|
|
1624
|
+
</xs:annotation>
|
|
1625
|
+
</xs:enumeration>
|
|
1626
|
+
<xs:enumeration value="gaseousHydrogen350barTruck">
|
|
1627
|
+
<xs:annotation>
|
|
1628
|
+
<xs:documentation>Gaseous hydrogen with 350 bar pressure for trucks.</xs:documentation>
|
|
1629
|
+
</xs:annotation>
|
|
1630
|
+
</xs:enumeration>
|
|
1631
|
+
<xs:enumeration value="gaseousHydrogen700barCar">
|
|
1632
|
+
<xs:annotation>
|
|
1633
|
+
<xs:documentation>Gaseous hydrogen with 700 bar pressure for cars.</xs:documentation>
|
|
1634
|
+
</xs:annotation>
|
|
1635
|
+
</xs:enumeration>
|
|
1636
|
+
<xs:enumeration value="gaseousHydrogen700barTruck">
|
|
1637
|
+
<xs:annotation>
|
|
1638
|
+
<xs:documentation>Gaseous hydrogen with 700 bar pressure for trucks.</xs:documentation>
|
|
1639
|
+
</xs:annotation>
|
|
1640
|
+
</xs:enumeration>
|
|
1641
|
+
<xs:enumeration value="liquidHydrogen">
|
|
1642
|
+
<xs:annotation>
|
|
1643
|
+
<xs:documentation>Liquid hydrogen.</xs:documentation>
|
|
1644
|
+
</xs:annotation>
|
|
1645
|
+
</xs:enumeration>
|
|
1646
|
+
<xs:enumeration value="cryoCompressedHydrogren">
|
|
1647
|
+
<xs:annotation>
|
|
1648
|
+
<xs:documentation>Cryo-compressed hydrogen.</xs:documentation>
|
|
1649
|
+
</xs:annotation>
|
|
1650
|
+
</xs:enumeration>
|
|
1651
|
+
<xs:enumeration value="unknown">
|
|
1652
|
+
<xs:annotation>
|
|
1653
|
+
<xs:documentation>The type of hydrogen is unknown.</xs:documentation>
|
|
1654
|
+
</xs:annotation>
|
|
1655
|
+
</xs:enumeration>
|
|
1656
|
+
<xs:enumeration value="other">
|
|
1657
|
+
<xs:annotation>
|
|
1658
|
+
<xs:documentation>Other hydrogen solution, especially another pressure.</xs:documentation>
|
|
1659
|
+
</xs:annotation>
|
|
1660
|
+
</xs:enumeration>
|
|
1661
|
+
<xs:enumeration value="_extended" />
|
|
1662
|
+
</xs:restriction>
|
|
1663
|
+
</xs:simpleType>
|
|
1664
|
+
<xs:simpleType name="KilogramPerDay">
|
|
1665
|
+
<xs:annotation>
|
|
1666
|
+
<xs:documentation>Kilogram per day (e.g. for hydrogen supply).</xs:documentation>
|
|
1667
|
+
</xs:annotation>
|
|
1668
|
+
<xs:restriction base="com:Float" />
|
|
1669
|
+
</xs:simpleType>
|
|
1670
|
+
<xs:simpleType name="OctaneTypeEnum">
|
|
1671
|
+
<xs:annotation>
|
|
1672
|
+
<xs:documentation>Types of octane rating.</xs:documentation>
|
|
1673
|
+
</xs:annotation>
|
|
1674
|
+
<xs:restriction base="xs:string">
|
|
1675
|
+
<xs:enumeration value="octane95">
|
|
1676
|
+
<xs:annotation>
|
|
1677
|
+
<xs:documentation>Petrol with an octane rating of 95.</xs:documentation>
|
|
1678
|
+
</xs:annotation>
|
|
1679
|
+
</xs:enumeration>
|
|
1680
|
+
<xs:enumeration value="octane98">
|
|
1681
|
+
<xs:annotation>
|
|
1682
|
+
<xs:documentation>Petrol with an octane rating of 98.</xs:documentation>
|
|
1683
|
+
</xs:annotation>
|
|
1684
|
+
</xs:enumeration>
|
|
1685
|
+
<xs:enumeration value="other">
|
|
1686
|
+
<xs:annotation>
|
|
1687
|
+
<xs:documentation>Other types of petrol.</xs:documentation>
|
|
1688
|
+
</xs:annotation>
|
|
1689
|
+
</xs:enumeration>
|
|
1690
|
+
<xs:enumeration value="_extended" />
|
|
1691
|
+
</xs:restriction>
|
|
1692
|
+
</xs:simpleType>
|
|
1693
|
+
<xs:complexType name="PetrolRefillPoint">
|
|
1694
|
+
<xs:annotation>
|
|
1695
|
+
<xs:documentation>A refill point for petrol.</xs:documentation>
|
|
1696
|
+
</xs:annotation>
|
|
1697
|
+
<xs:complexContent>
|
|
1698
|
+
<xs:extension base="aegi:RefillPoint">
|
|
1699
|
+
<xs:sequence>
|
|
1700
|
+
<xs:element name="petrolType" type="aegi:_PetrolTypeEnum" minOccurs="0" maxOccurs="1">
|
|
1701
|
+
<xs:annotation>
|
|
1702
|
+
<xs:documentation>Leaded or unleaded petrol.</xs:documentation>
|
|
1703
|
+
</xs:annotation>
|
|
1704
|
+
</xs:element>
|
|
1705
|
+
<xs:element name="octaneType" type="aegi:_OctaneTypeEnum" minOccurs="0" maxOccurs="1">
|
|
1706
|
+
<xs:annotation>
|
|
1707
|
+
<xs:documentation>Petrol's octane rating.</xs:documentation>
|
|
1708
|
+
</xs:annotation>
|
|
1709
|
+
</xs:element>
|
|
1710
|
+
<xs:element name="octane" type="com:NonNegativeInteger" minOccurs="0" maxOccurs="1">
|
|
1711
|
+
<xs:annotation>
|
|
1712
|
+
<xs:documentation>Petrol's octane value.</xs:documentation>
|
|
1713
|
+
</xs:annotation>
|
|
1714
|
+
</xs:element>
|
|
1715
|
+
<xs:element name="bioethanolShare" type="com:Percentage" minOccurs="0" maxOccurs="1">
|
|
1716
|
+
<xs:annotation>
|
|
1717
|
+
<xs:documentation>Share of bioethanol in petrol (typically 5% or 10%).</xs:documentation>
|
|
1718
|
+
</xs:annotation>
|
|
1719
|
+
</xs:element>
|
|
1720
|
+
<xs:element name="bioethanolType" type="aegi:_BioethanolTypeEnum" minOccurs="0" maxOccurs="1">
|
|
1721
|
+
<xs:annotation>
|
|
1722
|
+
<xs:documentation>Listing of common types of petrol with bioethanol.</xs:documentation>
|
|
1723
|
+
</xs:annotation>
|
|
1724
|
+
</xs:element>
|
|
1725
|
+
<xs:element name="_petrolRefillPointExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1726
|
+
</xs:sequence>
|
|
1727
|
+
</xs:extension>
|
|
1728
|
+
</xs:complexContent>
|
|
1729
|
+
</xs:complexType>
|
|
1730
|
+
<xs:simpleType name="PetrolTypeEnum">
|
|
1731
|
+
<xs:annotation>
|
|
1732
|
+
<xs:documentation>Leaded or unleaded petrol.</xs:documentation>
|
|
1733
|
+
</xs:annotation>
|
|
1734
|
+
<xs:restriction base="xs:string">
|
|
1735
|
+
<xs:enumeration value="leaded">
|
|
1736
|
+
<xs:annotation>
|
|
1737
|
+
<xs:documentation>Leaded petrol.</xs:documentation>
|
|
1738
|
+
</xs:annotation>
|
|
1739
|
+
</xs:enumeration>
|
|
1740
|
+
<xs:enumeration value="unleaded">
|
|
1741
|
+
<xs:annotation>
|
|
1742
|
+
<xs:documentation>Unleaded petrol.</xs:documentation>
|
|
1743
|
+
</xs:annotation>
|
|
1744
|
+
</xs:enumeration>
|
|
1745
|
+
<xs:enumeration value="_extended" />
|
|
1746
|
+
</xs:restriction>
|
|
1747
|
+
</xs:simpleType>
|
|
1748
|
+
<xs:complexType name="PlannedRefillPointStatus">
|
|
1749
|
+
<xs:annotation>
|
|
1750
|
+
<xs:documentation>Planned status information for a refill point,for example reservatons.</xs:documentation>
|
|
1751
|
+
</xs:annotation>
|
|
1752
|
+
<xs:sequence>
|
|
1753
|
+
<xs:element name="status" type="aegi:_RefillPointStatusEnum" minOccurs="1" maxOccurs="1">
|
|
1754
|
+
<xs:annotation>
|
|
1755
|
+
<xs:documentation>Status of the refill point.</xs:documentation>
|
|
1756
|
+
</xs:annotation>
|
|
1757
|
+
</xs:element>
|
|
1758
|
+
<xs:element name="overallPeriod" type="com:OverallPeriod" />
|
|
1759
|
+
<xs:element name="_plannedRefillPointStatusExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1760
|
+
</xs:sequence>
|
|
1761
|
+
</xs:complexType>
|
|
1762
|
+
<xs:simpleType name="PriceTypeEnum">
|
|
1763
|
+
<xs:annotation>
|
|
1764
|
+
<xs:documentation>The type of price for energy.</xs:documentation>
|
|
1765
|
+
</xs:annotation>
|
|
1766
|
+
<xs:restriction base="xs:string">
|
|
1767
|
+
<xs:enumeration value="pricePerMinute">
|
|
1768
|
+
<xs:annotation>
|
|
1769
|
+
<xs:documentation>The given price is per minute of charging.</xs:documentation>
|
|
1770
|
+
</xs:annotation>
|
|
1771
|
+
</xs:enumeration>
|
|
1772
|
+
<xs:enumeration value="pricePerKg">
|
|
1773
|
+
<xs:annotation>
|
|
1774
|
+
<xs:documentation>The given price is per kilogram of gas.</xs:documentation>
|
|
1775
|
+
</xs:annotation>
|
|
1776
|
+
</xs:enumeration>
|
|
1777
|
+
<xs:enumeration value="pricePerKWh">
|
|
1778
|
+
<xs:annotation>
|
|
1779
|
+
<xs:documentation>The given price is per kWh of electric energy.</xs:documentation>
|
|
1780
|
+
</xs:annotation>
|
|
1781
|
+
</xs:enumeration>
|
|
1782
|
+
<xs:enumeration value="basePrice">
|
|
1783
|
+
<xs:annotation>
|
|
1784
|
+
<xs:documentation>The given price is a base price, which has to be added.</xs:documentation>
|
|
1785
|
+
</xs:annotation>
|
|
1786
|
+
</xs:enumeration>
|
|
1787
|
+
<xs:enumeration value="flatRate">
|
|
1788
|
+
<xs:annotation>
|
|
1789
|
+
<xs:documentation>The given price is a flatrate price, independent of the fueled amunt.</xs:documentation>
|
|
1790
|
+
</xs:annotation>
|
|
1791
|
+
</xs:enumeration>
|
|
1792
|
+
<xs:enumeration value="free">
|
|
1793
|
+
<xs:annotation>
|
|
1794
|
+
<xs:documentation>Charging or refueling is free.</xs:documentation>
|
|
1795
|
+
</xs:annotation>
|
|
1796
|
+
</xs:enumeration>
|
|
1797
|
+
<xs:enumeration value="other">
|
|
1798
|
+
<xs:annotation>
|
|
1799
|
+
<xs:documentation>Other method of pricing.</xs:documentation>
|
|
1800
|
+
</xs:annotation>
|
|
1801
|
+
</xs:enumeration>
|
|
1802
|
+
<xs:enumeration value="_extended" />
|
|
1803
|
+
</xs:restriction>
|
|
1804
|
+
</xs:simpleType>
|
|
1805
|
+
<xs:simpleType name="RatePolicyEnum">
|
|
1806
|
+
<xs:annotation>
|
|
1807
|
+
<xs:documentation>Contract based or ad hoc prices for energy.</xs:documentation>
|
|
1808
|
+
</xs:annotation>
|
|
1809
|
+
<xs:restriction base="xs:string">
|
|
1810
|
+
<xs:enumeration value="contract">
|
|
1811
|
+
<xs:annotation>
|
|
1812
|
+
<xs:documentation>A contract defines the pricing.</xs:documentation>
|
|
1813
|
+
</xs:annotation>
|
|
1814
|
+
</xs:enumeration>
|
|
1815
|
+
<xs:enumeration value="adHoc">
|
|
1816
|
+
<xs:annotation>
|
|
1817
|
+
<xs:documentation>Prices are for ad hoc refueling.</xs:documentation>
|
|
1818
|
+
</xs:annotation>
|
|
1819
|
+
</xs:enumeration>
|
|
1820
|
+
<xs:enumeration value="_extended" />
|
|
1821
|
+
</xs:restriction>
|
|
1822
|
+
</xs:simpleType>
|
|
1823
|
+
<xs:complexType name="RefillPoint" abstract="true">
|
|
1824
|
+
<xs:annotation>
|
|
1825
|
+
<xs:documentation>Technical infrastructure at a specific location that facilitates an energy refilling process being connected to max. one vehicle at a time.</xs:documentation>
|
|
1826
|
+
</xs:annotation>
|
|
1827
|
+
<xs:complexContent>
|
|
1828
|
+
<xs:extension base="afac:Facility">
|
|
1829
|
+
<xs:sequence>
|
|
1830
|
+
<xs:element name="deliveryUnit" type="aegi:_DeliveryUnitEnum" minOccurs="1" maxOccurs="1">
|
|
1831
|
+
<xs:annotation>
|
|
1832
|
+
<xs:documentation>Measurement unit that is used for delivery and accounting the energy provided at this refill point.</xs:documentation>
|
|
1833
|
+
</xs:annotation>
|
|
1834
|
+
</xs:element>
|
|
1835
|
+
<xs:element name="maximumDeliveryAmount" type="aegi:Units" minOccurs="0" maxOccurs="1">
|
|
1836
|
+
<xs:annotation>
|
|
1837
|
+
<xs:documentation>Maximum delivery amount.</xs:documentation>
|
|
1838
|
+
</xs:annotation>
|
|
1839
|
+
</xs:element>
|
|
1840
|
+
<xs:element name="minimumDeliveryAmount" type="aegi:Units" minOccurs="0" maxOccurs="1">
|
|
1841
|
+
<xs:annotation>
|
|
1842
|
+
<xs:documentation>Minimum delivery amount.</xs:documentation>
|
|
1843
|
+
</xs:annotation>
|
|
1844
|
+
</xs:element>
|
|
1845
|
+
<xs:element name="modelType" type="com:MultilingualString" minOccurs="0" maxOccurs="1">
|
|
1846
|
+
<xs:annotation>
|
|
1847
|
+
<xs:documentation>A description of the refill point model type.</xs:documentation>
|
|
1848
|
+
</xs:annotation>
|
|
1849
|
+
</xs:element>
|
|
1850
|
+
<xs:element name="reservation" type="afac:_ReservationTypeEnum" minOccurs="0" maxOccurs="1">
|
|
1851
|
+
<xs:annotation>
|
|
1852
|
+
<xs:documentation>Information regarding options for reservation of a time frame.</xs:documentation>
|
|
1853
|
+
</xs:annotation>
|
|
1854
|
+
</xs:element>
|
|
1855
|
+
<xs:element name="energyProduct" type="aegi:EnergyProduct" minOccurs="0" maxOccurs="unbounded" />
|
|
1856
|
+
<xs:element name="_refillPointExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1857
|
+
</xs:sequence>
|
|
1858
|
+
</xs:extension>
|
|
1859
|
+
</xs:complexContent>
|
|
1860
|
+
</xs:complexType>
|
|
1861
|
+
<xs:complexType name="RefillPointStatus">
|
|
1862
|
+
<xs:annotation>
|
|
1863
|
+
<xs:documentation>Dynamic information on the status of the refill point.</xs:documentation>
|
|
1864
|
+
</xs:annotation>
|
|
1865
|
+
<xs:complexContent>
|
|
1866
|
+
<xs:extension base="afac:FacilityStatus">
|
|
1867
|
+
<xs:sequence>
|
|
1868
|
+
<xs:element name="status" type="aegi:_RefillPointStatusEnum" minOccurs="1" maxOccurs="1">
|
|
1869
|
+
<xs:annotation>
|
|
1870
|
+
<xs:documentation>Status of the refill point.</xs:documentation>
|
|
1871
|
+
</xs:annotation>
|
|
1872
|
+
</xs:element>
|
|
1873
|
+
<xs:element name="unitsInStock" type="aegi:Units" minOccurs="0" maxOccurs="1">
|
|
1874
|
+
<xs:annotation>
|
|
1875
|
+
<xs:documentation>Amount of delivery units still in stock (with delivery units as defined in the static information model).</xs:documentation>
|
|
1876
|
+
</xs:annotation>
|
|
1877
|
+
</xs:element>
|
|
1878
|
+
<xs:element name="energyRateUpdate" type="aegi:EnergyRateUpdate" minOccurs="0" maxOccurs="unbounded" />
|
|
1879
|
+
<xs:element name="waitingTime" type="afac:DurationValue" minOccurs="0">
|
|
1880
|
+
<xs:annotation>
|
|
1881
|
+
<xs:documentation>Estimated waiting time for customers without reservation</xs:documentation>
|
|
1882
|
+
</xs:annotation>
|
|
1883
|
+
</xs:element>
|
|
1884
|
+
<xs:element name="plannedRefillPointStatus" type="aegi:PlannedRefillPointStatus" minOccurs="0" maxOccurs="unbounded" />
|
|
1885
|
+
<xs:element name="_refillPointStatusExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1886
|
+
</xs:sequence>
|
|
1887
|
+
</xs:extension>
|
|
1888
|
+
</xs:complexContent>
|
|
1889
|
+
</xs:complexType>
|
|
1890
|
+
<xs:simpleType name="RefillPointStatusEnum">
|
|
1891
|
+
<xs:annotation>
|
|
1892
|
+
<xs:documentation>The status of a refill point.</xs:documentation>
|
|
1893
|
+
</xs:annotation>
|
|
1894
|
+
<xs:restriction base="xs:string">
|
|
1895
|
+
<xs:enumeration value="available">
|
|
1896
|
+
<xs:annotation>
|
|
1897
|
+
<xs:documentation>The refill point is not occupied, has got enough energy resources and can be used.</xs:documentation>
|
|
1898
|
+
</xs:annotation>
|
|
1899
|
+
</xs:enumeration>
|
|
1900
|
+
<xs:enumeration value="blocked">
|
|
1901
|
+
<xs:annotation>
|
|
1902
|
+
<xs:documentation>The refill point is not accessible because of a physical barrier, e.g. a car.</xs:documentation>
|
|
1903
|
+
</xs:annotation>
|
|
1904
|
+
</xs:enumeration>
|
|
1905
|
+
<xs:enumeration value="charging">
|
|
1906
|
+
<xs:annotation>
|
|
1907
|
+
<xs:documentation>The refill point is currently in use for charging.</xs:documentation>
|
|
1908
|
+
</xs:annotation>
|
|
1909
|
+
</xs:enumeration>
|
|
1910
|
+
<xs:enumeration value="faulted">
|
|
1911
|
+
<xs:annotation>
|
|
1912
|
+
<xs:documentation>The refill point has got a fault.</xs:documentation>
|
|
1913
|
+
</xs:annotation>
|
|
1914
|
+
</xs:enumeration>
|
|
1915
|
+
<xs:enumeration value="inoperative">
|
|
1916
|
+
<xs:annotation>
|
|
1917
|
+
<xs:documentation>The refill point is not yet active or it is no longer available (deleted).</xs:documentation>
|
|
1918
|
+
</xs:annotation>
|
|
1919
|
+
</xs:enumeration>
|
|
1920
|
+
<xs:enumeration value="occupied">
|
|
1921
|
+
<xs:annotation>
|
|
1922
|
+
<xs:documentation>The refill point is in use, this might include vehicle charging activity.</xs:documentation>
|
|
1923
|
+
</xs:annotation>
|
|
1924
|
+
</xs:enumeration>
|
|
1925
|
+
<xs:enumeration value="outOfOrder">
|
|
1926
|
+
<xs:annotation>
|
|
1927
|
+
<xs:documentation>The refill point is currently out of order.</xs:documentation>
|
|
1928
|
+
</xs:annotation>
|
|
1929
|
+
</xs:enumeration>
|
|
1930
|
+
<xs:enumeration value="outOfStock">
|
|
1931
|
+
<xs:annotation>
|
|
1932
|
+
<xs:documentation>The refill point is out of stock, i.e. energy resources are empty.</xs:documentation>
|
|
1933
|
+
</xs:annotation>
|
|
1934
|
+
</xs:enumeration>
|
|
1935
|
+
<xs:enumeration value="planned">
|
|
1936
|
+
<xs:annotation>
|
|
1937
|
+
<xs:documentation>The refill point is planned, will be operating soon.</xs:documentation>
|
|
1938
|
+
</xs:annotation>
|
|
1939
|
+
</xs:enumeration>
|
|
1940
|
+
<xs:enumeration value="removed">
|
|
1941
|
+
<xs:annotation>
|
|
1942
|
+
<xs:documentation>The refill point was discontinued/removed.</xs:documentation>
|
|
1943
|
+
</xs:annotation>
|
|
1944
|
+
</xs:enumeration>
|
|
1945
|
+
<xs:enumeration value="reserved">
|
|
1946
|
+
<xs:annotation>
|
|
1947
|
+
<xs:documentation>The refill point is reserved by a customer, i.e. it is not available for other users right now.</xs:documentation>
|
|
1948
|
+
</xs:annotation>
|
|
1949
|
+
</xs:enumeration>
|
|
1950
|
+
<xs:enumeration value="unavailable">
|
|
1951
|
+
<xs:annotation>
|
|
1952
|
+
<xs:documentation>There is no energy available at this refill point. This could be because of a failure or damage or a longer lasting delivery failure (note that there is a literal 'outOfStock' for a short-term shortage).</xs:documentation>
|
|
1953
|
+
</xs:annotation>
|
|
1954
|
+
</xs:enumeration>
|
|
1955
|
+
<xs:enumeration value="unknown">
|
|
1956
|
+
<xs:annotation>
|
|
1957
|
+
<xs:documentation>The status of the refill point is unknown (can also be offline).</xs:documentation>
|
|
1958
|
+
</xs:annotation>
|
|
1959
|
+
</xs:enumeration>
|
|
1960
|
+
<xs:enumeration value="_extended" />
|
|
1961
|
+
</xs:restriction>
|
|
1962
|
+
</xs:simpleType>
|
|
1963
|
+
<xs:complexType name="ServiceType">
|
|
1964
|
+
<xs:annotation>
|
|
1965
|
+
<xs:documentation>A specification of service types for the fuelling/charging and payment process.</xs:documentation>
|
|
1966
|
+
</xs:annotation>
|
|
1967
|
+
<xs:sequence>
|
|
1968
|
+
<xs:element name="serviceType" type="aegi:_ServiceTypeEnum" minOccurs="1" maxOccurs="1">
|
|
1969
|
+
<xs:annotation>
|
|
1970
|
+
<xs:documentation>Information on different service types for the fuelling/charging and payment process.</xs:documentation>
|
|
1971
|
+
</xs:annotation>
|
|
1972
|
+
</xs:element>
|
|
1973
|
+
<xs:element name="overallPeriod" type="com:OverallPeriod" minOccurs="0" />
|
|
1974
|
+
<xs:element name="_serviceTypeExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
1975
|
+
</xs:sequence>
|
|
1976
|
+
</xs:complexType>
|
|
1977
|
+
<xs:simpleType name="ServiceTypeEnum">
|
|
1978
|
+
<xs:annotation>
|
|
1979
|
+
<xs:documentation>A table of different service levels to be expected for fuelling/charging and payment.</xs:documentation>
|
|
1980
|
+
</xs:annotation>
|
|
1981
|
+
<xs:restriction base="xs:string">
|
|
1982
|
+
<xs:enumeration value="fullService">
|
|
1983
|
+
<xs:annotation>
|
|
1984
|
+
<xs:documentation>Full fuelling service carried out by an employee.</xs:documentation>
|
|
1985
|
+
</xs:annotation>
|
|
1986
|
+
</xs:enumeration>
|
|
1987
|
+
<xs:enumeration value="physicalAttendance">
|
|
1988
|
+
<xs:annotation>
|
|
1989
|
+
<xs:documentation>Presence of physical persons attending the recharging or refuelling station.</xs:documentation>
|
|
1990
|
+
</xs:annotation>
|
|
1991
|
+
</xs:enumeration>
|
|
1992
|
+
<xs:enumeration value="selfService">
|
|
1993
|
+
<xs:annotation>
|
|
1994
|
+
<xs:documentation>Self-service for fuelling.</xs:documentation>
|
|
1995
|
+
</xs:annotation>
|
|
1996
|
+
</xs:enumeration>
|
|
1997
|
+
<xs:enumeration value="unattended">
|
|
1998
|
+
<xs:annotation>
|
|
1999
|
+
<xs:documentation>Unattended station, fuelling and payment to be done without assistance.</xs:documentation>
|
|
2000
|
+
</xs:annotation>
|
|
2001
|
+
</xs:enumeration>
|
|
2002
|
+
<xs:enumeration value="_extended" />
|
|
2003
|
+
</xs:restriction>
|
|
2004
|
+
</xs:simpleType>
|
|
2005
|
+
<xs:simpleType name="SmartRechargingServicesEnum">
|
|
2006
|
+
<xs:annotation>
|
|
2007
|
+
<xs:documentation>Smart recharging services.</xs:documentation>
|
|
2008
|
+
</xs:annotation>
|
|
2009
|
+
<xs:restriction base="xs:string">
|
|
2010
|
+
<xs:enumeration value="remoteMonitoring">
|
|
2011
|
+
<xs:annotation>
|
|
2012
|
+
<xs:documentation>Remote monitoring and control recharging (e.g. by app).</xs:documentation>
|
|
2013
|
+
</xs:annotation>
|
|
2014
|
+
</xs:enumeration>
|
|
2015
|
+
<xs:enumeration value="powerOptimisationByUser">
|
|
2016
|
+
<xs:annotation>
|
|
2017
|
+
<xs:documentation>User preference configuration for recharging power optimization.</xs:documentation>
|
|
2018
|
+
</xs:annotation>
|
|
2019
|
+
</xs:enumeration>
|
|
2020
|
+
<xs:enumeration value="bidirectionalRecharging">
|
|
2021
|
+
<xs:annotation>
|
|
2022
|
+
<xs:documentation>Bidirectional charging.</xs:documentation>
|
|
2023
|
+
</xs:annotation>
|
|
2024
|
+
</xs:enumeration>
|
|
2025
|
+
<xs:enumeration value="plugAndCharge">
|
|
2026
|
+
<xs:annotation>
|
|
2027
|
+
<xs:documentation>Possibility of conducting automatic authentication and authorisation of the recharging session an the basis of a contract-based payment concluded between the end user and the mobility service provider in a recharging point as defined in ISO 15118-2 and -2</xs:documentation>
|
|
2028
|
+
</xs:annotation>
|
|
2029
|
+
</xs:enumeration>
|
|
2030
|
+
<xs:enumeration value="_extended" />
|
|
2031
|
+
</xs:restriction>
|
|
2032
|
+
</xs:simpleType>
|
|
2033
|
+
<xs:complexType name="TimeBasedApplicability">
|
|
2034
|
+
<xs:annotation>
|
|
2035
|
+
<xs:documentation>Price is only valid within the given charging time boundaries in minutes.</xs:documentation>
|
|
2036
|
+
</xs:annotation>
|
|
2037
|
+
<xs:sequence>
|
|
2038
|
+
<xs:element name="fromMinute" type="com:NonNegativeInteger" minOccurs="0" maxOccurs="1">
|
|
2039
|
+
<xs:annotation>
|
|
2040
|
+
<xs:documentation>Price is valid from the given minute.</xs:documentation>
|
|
2041
|
+
</xs:annotation>
|
|
2042
|
+
</xs:element>
|
|
2043
|
+
<xs:element name="toMinute" type="com:NonNegativeInteger" minOccurs="0" maxOccurs="1">
|
|
2044
|
+
<xs:annotation>
|
|
2045
|
+
<xs:documentation>Price is valid up to the given minute.</xs:documentation>
|
|
2046
|
+
</xs:annotation>
|
|
2047
|
+
</xs:element>
|
|
2048
|
+
<xs:element name="_timeBasedApplicabilityExtension" type="com:_ExtensionType" minOccurs="0" />
|
|
2049
|
+
</xs:sequence>
|
|
2050
|
+
</xs:complexType>
|
|
2051
|
+
<xs:simpleType name="Units">
|
|
2052
|
+
<xs:annotation>
|
|
2053
|
+
<xs:documentation>Allows to specify amounts in generic terms of a Unit,which can be one of the elements in DeliveryUnitEnum.</xs:documentation>
|
|
2054
|
+
</xs:annotation>
|
|
2055
|
+
<xs:restriction base="com:Float" />
|
|
2056
|
+
</xs:simpleType>
|
|
2057
|
+
<xs:simpleType name="VehicleToGridCommunicationTypeEnum">
|
|
2058
|
+
<xs:annotation>
|
|
2059
|
+
<xs:documentation>A list of communication types for communication between vehicles and the grid.</xs:documentation>
|
|
2060
|
+
</xs:annotation>
|
|
2061
|
+
<xs:restriction base="xs:string">
|
|
2062
|
+
<xs:enumeration value="none">
|
|
2063
|
+
<xs:annotation>
|
|
2064
|
+
<xs:documentation>No communication between vehicle and the grid.</xs:documentation>
|
|
2065
|
+
</xs:annotation>
|
|
2066
|
+
</xs:enumeration>
|
|
2067
|
+
<xs:enumeration value="iso15118">
|
|
2068
|
+
<xs:annotation>
|
|
2069
|
+
<xs:documentation>Communication according to ISO15118-20.</xs:documentation>
|
|
2070
|
+
</xs:annotation>
|
|
2071
|
+
</xs:enumeration>
|
|
2072
|
+
<xs:enumeration value="iec619802">
|
|
2073
|
+
<xs:annotation>
|
|
2074
|
+
<xs:documentation>Communication according to IEC/TS 61980-2.</xs:documentation>
|
|
2075
|
+
</xs:annotation>
|
|
2076
|
+
</xs:enumeration>
|
|
2077
|
+
<xs:enumeration value="other">
|
|
2078
|
+
<xs:annotation>
|
|
2079
|
+
<xs:documentation>Communication according to other guidelines/specifications.</xs:documentation>
|
|
2080
|
+
</xs:annotation>
|
|
2081
|
+
</xs:enumeration>
|
|
2082
|
+
<xs:enumeration value="unknown">
|
|
2083
|
+
<xs:annotation>
|
|
2084
|
+
<xs:documentation>The type of communication is unknown.</xs:documentation>
|
|
2085
|
+
</xs:annotation>
|
|
2086
|
+
</xs:enumeration>
|
|
2087
|
+
<xs:enumeration value="_extended" />
|
|
2088
|
+
</xs:restriction>
|
|
2089
|
+
</xs:simpleType>
|
|
2090
|
+
<xs:simpleType name="Volt">
|
|
2091
|
+
<xs:annotation>
|
|
2092
|
+
<xs:documentation>Volt.</xs:documentation>
|
|
2093
|
+
</xs:annotation>
|
|
2094
|
+
<xs:restriction base="com:Float" />
|
|
2095
|
+
</xs:simpleType>
|
|
2096
|
+
<xs:simpleType name="Watt">
|
|
2097
|
+
<xs:annotation>
|
|
2098
|
+
<xs:documentation>Watt.</xs:documentation>
|
|
2099
|
+
</xs:annotation>
|
|
2100
|
+
<xs:restriction base="com:Float" />
|
|
2101
|
+
</xs:simpleType>
|
|
2102
|
+
</xs:schema>
|