cimhub-gridlabd 2.0.0a1__py3-none-any.whl
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- cimhub_gridlabd/__init__.py +3 -0
- cimhub_gridlabd/exporter/__init__.py +10 -0
- cimhub_gridlabd/exporter/base/__init__.py +1 -0
- cimhub_gridlabd/exporter/base/node.py +220 -0
- cimhub_gridlabd/exporter/cim_to_glm.py +232 -0
- cimhub_gridlabd/exporter/generators/__init__.py +14 -0
- cimhub_gridlabd/exporter/generators/battery.py +66 -0
- cimhub_gridlabd/exporter/generators/inverter.py +237 -0
- cimhub_gridlabd/exporter/generators/machine.py +180 -0
- cimhub_gridlabd/exporter/generators/machine_dynamics.py +100 -0
- cimhub_gridlabd/exporter/generators/solar.py +49 -0
- cimhub_gridlabd/exporter/glm_registry.py +8 -0
- cimhub_gridlabd/exporter/glm_text_writer.py +323 -0
- cimhub_gridlabd/exporter/glm_writer.py +167 -0
- cimhub_gridlabd/exporter/lines/__init__.py +9 -0
- cimhub_gridlabd/exporter/lines/line.py +205 -0
- cimhub_gridlabd/exporter/lines/line_configuration.py +299 -0
- cimhub_gridlabd/exporter/lines/line_spacing.py +245 -0
- cimhub_gridlabd/exporter/lines/underground_line_conductor.py +257 -0
- cimhub_gridlabd/exporter/loads/__init__.py +1 -0
- cimhub_gridlabd/exporter/loads/load.py +210 -0
- cimhub_gridlabd/exporter/shunts/__init__.py +2 -0
- cimhub_gridlabd/exporter/shunts/capacitor.py +72 -0
- cimhub_gridlabd/exporter/switches/__init__.py +3 -0
- cimhub_gridlabd/exporter/switches/_common.py +98 -0
- cimhub_gridlabd/exporter/switches/fuse.py +32 -0
- cimhub_gridlabd/exporter/switches/recloser.py +32 -0
- cimhub_gridlabd/exporter/switches/switch.py +35 -0
- cimhub_gridlabd/exporter/transformers/__init__.py +6 -0
- cimhub_gridlabd/exporter/transformers/regulator.py +345 -0
- cimhub_gridlabd/exporter/transformers/transformer.py +146 -0
- cimhub_gridlabd/exporter/transformers/transformer_configuration.py +520 -0
- cimhub_gridlabd/exporter/utils/__init__.py +4 -0
- cimhub_gridlabd/exporter/utils/phasing.py +163 -0
- cimhub_gridlabd/exporter/utils/ratings.py +36 -0
- cimhub_gridlabd/importer/__init__.py +15 -0
- cimhub_gridlabd/importer/base/__init__.py +15 -0
- cimhub_gridlabd/importer/base/node.py +87 -0
- cimhub_gridlabd/importer/base/substation.py +47 -0
- cimhub_gridlabd/importer/base/triplex_node.py +52 -0
- cimhub_gridlabd/importer/capacitors/__init__.py +2 -0
- cimhub_gridlabd/importer/capacitors/capacitor.py +93 -0
- cimhub_gridlabd/importer/common.py +105 -0
- cimhub_gridlabd/importer/glm_reader.py +495 -0
- cimhub_gridlabd/importer/glm_registry.py +7 -0
- cimhub_gridlabd/importer/glm_serialization.py +219 -0
- cimhub_gridlabd/importer/glm_text_reader.py +346 -0
- cimhub_gridlabd/importer/glm_to_cim.py +212 -0
- cimhub_gridlabd/importer/lines/__init__.py +13 -0
- cimhub_gridlabd/importer/lines/_wire_assembly.py +90 -0
- cimhub_gridlabd/importer/lines/line_configuration.py +56 -0
- cimhub_gridlabd/importer/lines/line_spacing.py +59 -0
- cimhub_gridlabd/importer/lines/overhead_line.py +47 -0
- cimhub_gridlabd/importer/lines/overhead_line_conductor.py +33 -0
- cimhub_gridlabd/importer/lines/triplex_line.py +62 -0
- cimhub_gridlabd/importer/lines/underground_line.py +37 -0
- cimhub_gridlabd/importer/lines/underground_line_conductor.py +45 -0
- cimhub_gridlabd/importer/loads/__init__.py +2 -0
- cimhub_gridlabd/importer/loads/load.py +63 -0
- cimhub_gridlabd/importer/switches/__init__.py +2 -0
- cimhub_gridlabd/importer/switches/switch.py +31 -0
- cimhub_gridlabd/importer/transformers/__init__.py +4 -0
- cimhub_gridlabd/importer/transformers/regulator.py +128 -0
- cimhub_gridlabd/importer/transformers/transformer.py +164 -0
- cimhub_gridlabd/importer/transformers/transformer_configuration.py +161 -0
- cimhub_gridlabd/schema/cpp_parser.py +269 -0
- cimhub_gridlabd/schema/gridlabd.py +27136 -0
- cimhub_gridlabd/schema/linkml/_directives/define.yaml +19 -0
- cimhub_gridlabd/schema/linkml/_directives/set.yaml +19 -0
- cimhub_gridlabd/schema/linkml/generators/battery.yaml +780 -0
- cimhub_gridlabd/schema/linkml/generators/central_dg_control.yaml +112 -0
- cimhub_gridlabd/schema/linkml/generators/controller_dg.yaml +262 -0
- cimhub_gridlabd/schema/linkml/generators/diesel_dg.yaml +2881 -0
- cimhub_gridlabd/schema/linkml/generators/energy_storage.yaml +244 -0
- cimhub_gridlabd/schema/linkml/generators/inverter.yaml +2708 -0
- cimhub_gridlabd/schema/linkml/generators/inverter_dyn.yaml +2087 -0
- cimhub_gridlabd/schema/linkml/generators/rectifier.yaml +190 -0
- cimhub_gridlabd/schema/linkml/generators/solar.yaml +645 -0
- cimhub_gridlabd/schema/linkml/generators/sync_ctrl.yaml +297 -0
- cimhub_gridlabd/schema/linkml/generators/windturb_dg.yaml +1075 -0
- cimhub_gridlabd/schema/linkml/main.yaml +115 -0
- cimhub_gridlabd/schema/linkml/powerflow/billdump.yaml +73 -0
- cimhub_gridlabd/schema/linkml/powerflow/capacitor.yaml +376 -0
- cimhub_gridlabd/schema/linkml/powerflow/currdump.yaml +72 -0
- cimhub_gridlabd/schema/linkml/powerflow/emissions.yaml +1069 -0
- cimhub_gridlabd/schema/linkml/powerflow/fault_check.yaml +89 -0
- cimhub_gridlabd/schema/linkml/powerflow/fuse.yaml +103 -0
- cimhub_gridlabd/schema/linkml/powerflow/impedance_dump.yaml +63 -0
- cimhub_gridlabd/schema/linkml/powerflow/jsondump.yaml +133 -0
- cimhub_gridlabd/schema/linkml/powerflow/line.yaml +111 -0
- cimhub_gridlabd/schema/linkml/powerflow/line_configuration.yaml +312 -0
- cimhub_gridlabd/schema/linkml/powerflow/line_spacing.yaml +148 -0
- cimhub_gridlabd/schema/linkml/powerflow/link.yaml +711 -0
- cimhub_gridlabd/schema/linkml/powerflow/load.yaml +1470 -0
- cimhub_gridlabd/schema/linkml/powerflow/load_tracker.yaml +111 -0
- cimhub_gridlabd/schema/linkml/powerflow/meter.yaml +1248 -0
- cimhub_gridlabd/schema/linkml/powerflow/motor.yaml +893 -0
- cimhub_gridlabd/schema/linkml/powerflow/node.yaml +1170 -0
- cimhub_gridlabd/schema/linkml/powerflow/overhead_line.yaml +31 -0
- cimhub_gridlabd/schema/linkml/powerflow/overhead_line_conductor.yaml +118 -0
- cimhub_gridlabd/schema/linkml/powerflow/performance_motor.yaml +407 -0
- cimhub_gridlabd/schema/linkml/powerflow/power_metrics.yaml +193 -0
- cimhub_gridlabd/schema/linkml/powerflow/powerflow_object.yaml +112 -0
- cimhub_gridlabd/schema/linkml/powerflow/pqload.yaml +603 -0
- cimhub_gridlabd/schema/linkml/powerflow/recloser.yaml +68 -0
- cimhub_gridlabd/schema/linkml/powerflow/regulator.yaml +168 -0
- cimhub_gridlabd/schema/linkml/powerflow/regulator_configuration.yaml +306 -0
- cimhub_gridlabd/schema/linkml/powerflow/restoration.yaml +163 -0
- cimhub_gridlabd/schema/linkml/powerflow/sectionalizer.yaml +31 -0
- cimhub_gridlabd/schema/linkml/powerflow/series_compensator.yaml +549 -0
- cimhub_gridlabd/schema/linkml/powerflow/series_reactor.yaml +144 -0
- cimhub_gridlabd/schema/linkml/powerflow/substation.yaml +297 -0
- cimhub_gridlabd/schema/linkml/powerflow/switch.yaml +109 -0
- cimhub_gridlabd/schema/linkml/powerflow/sync_check.yaml +372 -0
- cimhub_gridlabd/schema/linkml/powerflow/transformer.yaml +230 -0
- cimhub_gridlabd/schema/linkml/powerflow/transformer_configuration.yaml +512 -0
- cimhub_gridlabd/schema/linkml/powerflow/triplex_line.yaml +31 -0
- cimhub_gridlabd/schema/linkml/powerflow/triplex_line_conductor.yaml +106 -0
- cimhub_gridlabd/schema/linkml/powerflow/triplex_line_configuration.yaml +187 -0
- cimhub_gridlabd/schema/linkml/powerflow/triplex_load.yaml +729 -0
- cimhub_gridlabd/schema/linkml/powerflow/triplex_meter.yaml +812 -0
- cimhub_gridlabd/schema/linkml/powerflow/triplex_node.yaml +822 -0
- cimhub_gridlabd/schema/linkml/powerflow/underground_line.yaml +31 -0
- cimhub_gridlabd/schema/linkml/powerflow/underground_line_conductor.yaml +236 -0
- cimhub_gridlabd/schema/linkml/powerflow/vfd.yaml +156 -0
- cimhub_gridlabd/schema/linkml/powerflow/volt_var_control.yaml +217 -0
- cimhub_gridlabd/schema/linkml/powerflow/voltdump.yaml +82 -0
- cimhub_gridlabd/schema/linkml/residential/ZIPload.yaml +372 -0
- cimhub_gridlabd/schema/linkml/residential/appliance.yaml +83 -0
- cimhub_gridlabd/schema/linkml/residential/clotheswasher.yaml +596 -0
- cimhub_gridlabd/schema/linkml/residential/dishwasher.yaml +882 -0
- cimhub_gridlabd/schema/linkml/residential/dryer.yaml +601 -0
- cimhub_gridlabd/schema/linkml/residential/evcharger.yaml +192 -0
- cimhub_gridlabd/schema/linkml/residential/evcharger_det.yaml +557 -0
- cimhub_gridlabd/schema/linkml/residential/freezer.yaml +179 -0
- cimhub_gridlabd/schema/linkml/residential/house.yaml +2171 -0
- cimhub_gridlabd/schema/linkml/residential/house_a.yaml +480 -0
- cimhub_gridlabd/schema/linkml/residential/lights.yaml +122 -0
- cimhub_gridlabd/schema/linkml/residential/microwave.yaml +126 -0
- cimhub_gridlabd/schema/linkml/residential/occupantload.yaml +68 -0
- cimhub_gridlabd/schema/linkml/residential/plugload.yaml +82 -0
- cimhub_gridlabd/schema/linkml/residential/range.yaml +711 -0
- cimhub_gridlabd/schema/linkml/residential/refrigerator.yaml +598 -0
- cimhub_gridlabd/schema/linkml/residential/thermal_storage.yaml +212 -0
- cimhub_gridlabd/schema/linkml/residential/waterheater.yaml +640 -0
- cimhub_gridlabd/schema/linkml/types/common.yaml +2014 -0
- cimhub_gridlabd/schema/linkml_generator.py +496 -0
- cimhub_gridlabd/schema/property_parser.py +460 -0
- cimhub_gridlabd-2.0.0a1.dist-info/METADATA +110 -0
- cimhub_gridlabd-2.0.0a1.dist-info/RECORD +152 -0
- cimhub_gridlabd-2.0.0a1.dist-info/WHEEL +5 -0
- cimhub_gridlabd-2.0.0a1.dist-info/top_level.txt +1 -0
|
@@ -0,0 +1,10 @@
|
|
|
1
|
+
from cimhub_gridlabd.exporter.glm_writer import GlmJsonWriter
|
|
2
|
+
|
|
3
|
+
__all__ = ["GlmJsonWriter"]
|
|
4
|
+
|
|
5
|
+
# CIM conversion functions require cimgraph — only export when available
|
|
6
|
+
try:
|
|
7
|
+
from cimhub_gridlabd.exporter.cim_to_glm import cim_to_glm, cim_to_glm_json # noqa: F401
|
|
8
|
+
__all__ += ["cim_to_glm", "cim_to_glm_json"]
|
|
9
|
+
except ImportError:
|
|
10
|
+
pass
|
|
@@ -0,0 +1 @@
|
|
|
1
|
+
from cimhub_gridlabd.exporter.base.node import convert_connectivity_node
|
|
@@ -0,0 +1,220 @@
|
|
|
1
|
+
from __future__ import annotations
|
|
2
|
+
|
|
3
|
+
import importlib
|
|
4
|
+
import logging
|
|
5
|
+
import math
|
|
6
|
+
|
|
7
|
+
import cimgraph.data_profile.cimhub_2026 as cim
|
|
8
|
+
|
|
9
|
+
from cimhub_core import GraphModel
|
|
10
|
+
from cimhub_gridlabd.schema import gridlabd as glm_schema
|
|
11
|
+
from cimhub_gridlabd.exporter.glm_registry import glm_exporter_registry
|
|
12
|
+
from cimhub_gridlabd.exporter.utils.phasing import collect_phases
|
|
13
|
+
|
|
14
|
+
_log = logging.getLogger(__name__)
|
|
15
|
+
|
|
16
|
+
|
|
17
|
+
def _voltage_from_transformer(terminal, xfmr, cim_mod) -> float | None:
|
|
18
|
+
"""Return the rated voltage (V, line-to-line) for this terminal's side of xfmr.
|
|
19
|
+
|
|
20
|
+
Walks PowerTransformerEnds + TransformerTankEnds looking for an end whose
|
|
21
|
+
Terminal matches *terminal*. Returns ``ratedU`` (in V) if found.
|
|
22
|
+
"""
|
|
23
|
+
for end in getattr(xfmr, "PowerTransformerEnd", []):
|
|
24
|
+
if getattr(end, "Terminal", None) is terminal:
|
|
25
|
+
v = getattr(end, "ratedU", None)
|
|
26
|
+
if v is not None:
|
|
27
|
+
return float(v)
|
|
28
|
+
for tank in getattr(xfmr, "TransformerTanks", []):
|
|
29
|
+
for end in getattr(tank, "TransformerTankEnds", []):
|
|
30
|
+
if getattr(end, "Terminal", None) is terminal:
|
|
31
|
+
v = getattr(end, "ratedU", None)
|
|
32
|
+
if v is not None:
|
|
33
|
+
return float(v)
|
|
34
|
+
return None
|
|
35
|
+
|
|
36
|
+
|
|
37
|
+
@glm_exporter_registry.register(cim.ConnectivityNode)
|
|
38
|
+
def convert_connectivity_node(node: cim.ConnectivityNode, glm_model: GraphModel) -> dict:
|
|
39
|
+
cim: cim = importlib.import_module(node.__module__)
|
|
40
|
+
|
|
41
|
+
phases = []
|
|
42
|
+
ll_voltages: list[float] = [] # line-to-line (from BaseVoltage) — divide by sqrt(3)
|
|
43
|
+
ln_voltages: list[float] = [] # line-to-neutral (from transformer ratedU) — use as-is
|
|
44
|
+
is_swing_bus = False
|
|
45
|
+
is_swing_pq = False
|
|
46
|
+
is_triplex = False
|
|
47
|
+
glm_node = {}
|
|
48
|
+
glm_node["name"] = node.name or node.uri()
|
|
49
|
+
|
|
50
|
+
# Collect phasing and nominal voltage
|
|
51
|
+
for terminal in node.Terminals:
|
|
52
|
+
equipment = terminal.ConductingEquipment
|
|
53
|
+
if equipment is None:
|
|
54
|
+
continue
|
|
55
|
+
|
|
56
|
+
# Swing bus detection: EnergySource or a regulating network injection.
|
|
57
|
+
# CIM17 calls it EquivalentInjection; CIM18/cimhub_2026 renamed it
|
|
58
|
+
# ExternalNetworkInjection. Match whichever the profile defines.
|
|
59
|
+
injection_cls = getattr(cim, "ExternalNetworkInjection", None) or getattr(
|
|
60
|
+
cim, "EquivalentInjection", None
|
|
61
|
+
)
|
|
62
|
+
if isinstance(equipment, cim.EnergySource):
|
|
63
|
+
is_swing_bus = True
|
|
64
|
+
elif injection_cls is not None and isinstance(equipment, injection_cls):
|
|
65
|
+
if getattr(equipment, "regulationStatus", False):
|
|
66
|
+
is_swing_bus = True
|
|
67
|
+
|
|
68
|
+
if equipment.BaseVoltage is not None:
|
|
69
|
+
# BaseVoltage.nominalVoltage is line-to-line — convert to LN later
|
|
70
|
+
ll_voltages.append(float(equipment.BaseVoltage.nominalVoltage))
|
|
71
|
+
elif isinstance(equipment, cim.PowerTransformer):
|
|
72
|
+
# TransformerEnd.Terminal back-ref may be empty — walk the transformer
|
|
73
|
+
# ends directly and match by terminal to find the rated voltage.
|
|
74
|
+
# TransformerEnd.ratedU is line-to-line for multi-phase ends; for single-
|
|
75
|
+
# phase (center-tap) ends it's line-to-neutral. Both are stored as V.
|
|
76
|
+
# We track these separately so we can later pick the right one.
|
|
77
|
+
v = _voltage_from_transformer(terminal, equipment, cim)
|
|
78
|
+
if v is not None:
|
|
79
|
+
ln_voltages.append(float(v))
|
|
80
|
+
else:
|
|
81
|
+
# For switches/lines with no BaseVoltage, look through the OTHER terminal
|
|
82
|
+
# of the same equipment to its connectivity node's equipment BaseVoltage.
|
|
83
|
+
for other_t in getattr(equipment, "Terminals", []):
|
|
84
|
+
if other_t is terminal:
|
|
85
|
+
continue
|
|
86
|
+
other_cn = getattr(other_t, "ConnectivityNode", None)
|
|
87
|
+
if other_cn is None:
|
|
88
|
+
continue
|
|
89
|
+
for other_t2 in getattr(other_cn, "Terminals", []):
|
|
90
|
+
eq2 = other_t2.ConductingEquipment
|
|
91
|
+
if eq2 is equipment:
|
|
92
|
+
continue
|
|
93
|
+
if getattr(eq2, "BaseVoltage", None) is not None:
|
|
94
|
+
ll_voltages.append(float(eq2.BaseVoltage.nominalVoltage))
|
|
95
|
+
break
|
|
96
|
+
if ll_voltages:
|
|
97
|
+
break
|
|
98
|
+
|
|
99
|
+
phases.append(collect_phases(equipment))
|
|
100
|
+
|
|
101
|
+
# Detect triplex (secondary system) nodes
|
|
102
|
+
if "S" in "".join(phases):
|
|
103
|
+
is_triplex = True
|
|
104
|
+
|
|
105
|
+
# Detect DER types connected to this node — used for sub-meter emission and
|
|
106
|
+
# SWING_PQ classification (matches Java GldNode.bSolarInverters / bStorageInverters
|
|
107
|
+
# / bSyncMachines flags).
|
|
108
|
+
has_pv = False
|
|
109
|
+
has_storage = False
|
|
110
|
+
has_sync = False
|
|
111
|
+
for terminal in node.Terminals:
|
|
112
|
+
eq = terminal.ConductingEquipment
|
|
113
|
+
if isinstance(eq, cim.PowerElectronicsConnection):
|
|
114
|
+
for unit in (eq.PowerElectronicsUnit or []):
|
|
115
|
+
if isinstance(unit, cim.PhotoVoltaicUnit):
|
|
116
|
+
has_pv = True
|
|
117
|
+
elif isinstance(unit, cim.BatteryUnit):
|
|
118
|
+
has_storage = True
|
|
119
|
+
elif isinstance(eq, cim.SynchronousMachine):
|
|
120
|
+
has_sync = True
|
|
121
|
+
|
|
122
|
+
# Assign phases to node. Java appends "N" for primary nodes via GetPhases(false)
|
|
123
|
+
# and "S" for secondary. Python replicates that here.
|
|
124
|
+
sorted_phases = sorted("".join(set(sorted("".join(phases)))))
|
|
125
|
+
if is_triplex:
|
|
126
|
+
# collect_phases already returns the secondary form as "<letter>S", so the
|
|
127
|
+
# letters here may already carry the S — appending another would emit "CSS".
|
|
128
|
+
# GridLAB-D needs "<letter>S" ("CS"), never a bare "S": a bare S compiles
|
|
129
|
+
# but leaves the triplex with no primary phase, which surfaces as wrong
|
|
130
|
+
# secondary voltages at run time rather than as a load-time error.
|
|
131
|
+
letters = "".join(p for p in sorted_phases if p != "S")
|
|
132
|
+
if not letters:
|
|
133
|
+
raise ValueError(
|
|
134
|
+
f"node {node.name}: triplex node has no primary phase letter "
|
|
135
|
+
f"(collected {phases!r}); GridLAB-D requires 'AS'/'BS'/'CS'"
|
|
136
|
+
)
|
|
137
|
+
glm_node["phases"] = letters + "S"
|
|
138
|
+
elif sorted_phases:
|
|
139
|
+
glm_node["phases"] = "".join(sorted_phases) + "N"
|
|
140
|
+
else:
|
|
141
|
+
glm_node["phases"] = "ABCN"
|
|
142
|
+
|
|
143
|
+
# Assign base voltage to node.
|
|
144
|
+
# BaseVoltage.nominalVoltage is line-to-line (LL); divide by sqrt(3) or 2.
|
|
145
|
+
# TransformerEnd.ratedU is used as-is (already LN for the relevant end).
|
|
146
|
+
# Prefer the LL source (more common/reliable) when available.
|
|
147
|
+
ll_to_ln = 2.0 if is_triplex else math.sqrt(3)
|
|
148
|
+
if ll_voltages:
|
|
149
|
+
ln_cand = [v / ll_to_ln for v in set(ll_voltages)]
|
|
150
|
+
elif ln_voltages:
|
|
151
|
+
ln_cand = list(set(ln_voltages))
|
|
152
|
+
else:
|
|
153
|
+
ln_cand = []
|
|
154
|
+
|
|
155
|
+
if len(ln_cand) == 0:
|
|
156
|
+
_log.warning(f"Unable to determine base voltage of Node {node.name}")
|
|
157
|
+
glm_node["nominal_voltage"] = None
|
|
158
|
+
else:
|
|
159
|
+
if len(ln_cand) > 1:
|
|
160
|
+
_log.warning(f"Node {node.name} has multiple voltages; using lowest")
|
|
161
|
+
glm_node["nominal_voltage"] = min(ln_cand)
|
|
162
|
+
|
|
163
|
+
node_name = glm_node["name"]
|
|
164
|
+
|
|
165
|
+
# Convert dict to appropriate GLM schema dataclass
|
|
166
|
+
if is_swing_bus:
|
|
167
|
+
glm_node["bustype"] = "SWING"
|
|
168
|
+
# These values were hard-coded previously, keeping the same
|
|
169
|
+
glm_node["base_power"] = "12MVA"
|
|
170
|
+
glm_node["positive_sequence_voltage"] = "${VSOURCE}"
|
|
171
|
+
glm_node["power_convergence_value"] = "100VA"
|
|
172
|
+
glm_node["outside_comments"] = [f"EnergySource Name:{node.name}"]
|
|
173
|
+
|
|
174
|
+
# Create Substation dataclass instance
|
|
175
|
+
substation = glm_schema.Substation()
|
|
176
|
+
for key, value in glm_node.items():
|
|
177
|
+
setattr(substation, key, value)
|
|
178
|
+
glm_model.add_to_graph(substation)
|
|
179
|
+
|
|
180
|
+
elif is_triplex:
|
|
181
|
+
glm_node["outside_comments"] = [f"Name:{node.name}"]
|
|
182
|
+
|
|
183
|
+
# Create TriplexNode dataclass instance
|
|
184
|
+
triplex_node = glm_schema.TriplexNode()
|
|
185
|
+
for key, value in glm_node.items():
|
|
186
|
+
setattr(triplex_node, key, value)
|
|
187
|
+
glm_model.add_to_graph(triplex_node)
|
|
188
|
+
|
|
189
|
+
# Sub-meters for DER at triplex (secondary) nodes — mirrors Java AppendSubMeter
|
|
190
|
+
for suffix, present in (("_pvmtr", has_pv), ("_stmtr", has_storage), ("_dgmtr", has_sync)):
|
|
191
|
+
if not present:
|
|
192
|
+
continue
|
|
193
|
+
sub = glm_schema.TriplexMeter()
|
|
194
|
+
sub.name = node_name + suffix
|
|
195
|
+
sub.parent = node_name
|
|
196
|
+
sub.phases = glm_node["phases"]
|
|
197
|
+
sub.nominal_voltage = glm_node["nominal_voltage"]
|
|
198
|
+
glm_model.add_to_graph(sub)
|
|
199
|
+
|
|
200
|
+
else:
|
|
201
|
+
if has_storage or has_sync:
|
|
202
|
+
glm_node["bustype"] = "SWING_PQ"
|
|
203
|
+
glm_node["outside_comments"] = [f"Name:{node.name}"]
|
|
204
|
+
|
|
205
|
+
# Create Node dataclass instance
|
|
206
|
+
node_obj = glm_schema.Node()
|
|
207
|
+
for key, value in glm_node.items():
|
|
208
|
+
setattr(node_obj, key, value)
|
|
209
|
+
glm_model.add_to_graph(node_obj)
|
|
210
|
+
|
|
211
|
+
# Sub-meters for DER at primary nodes — mirrors Java AppendSubMeter
|
|
212
|
+
for suffix, present in (("_pvmtr", has_pv), ("_stmtr", has_storage), ("_dgmtr", has_sync)):
|
|
213
|
+
if not present:
|
|
214
|
+
continue
|
|
215
|
+
sub = glm_schema.Meter()
|
|
216
|
+
sub.name = node_name + suffix
|
|
217
|
+
sub.parent = node_name
|
|
218
|
+
sub.phases = glm_node["phases"]
|
|
219
|
+
sub.nominal_voltage = glm_node["nominal_voltage"]
|
|
220
|
+
glm_model.add_to_graph(sub)
|
|
@@ -0,0 +1,232 @@
|
|
|
1
|
+
"""CIM to GridLAB-D GLM converter orchestrator.
|
|
2
|
+
|
|
3
|
+
This module coordinates the conversion from CIM (cimgraph) to GridLAB-D GLM format
|
|
4
|
+
following the cimhub architecture pattern (mirrors ``cimhub_opendss.cim_to_dss``):
|
|
5
|
+
|
|
6
|
+
CIM FeederModel -> registered converters -> GLM schema dataclasses
|
|
7
|
+
-> GraphModel -> GlmJsonWriter -> GLM-JSON file
|
|
8
|
+
|
|
9
|
+
The conversion process:
|
|
10
|
+
1. Iterate CIM classes in dependency order (``EXPORT_ORDER``)
|
|
11
|
+
2. Dispatch each instance to its registered converter via ``glm_exporter_registry``
|
|
12
|
+
3. Converters add GLM schema dataclasses to the GraphModel
|
|
13
|
+
4. Return the GraphModel (serialization handled by ``GlmJsonWriter``)
|
|
14
|
+
"""
|
|
15
|
+
from __future__ import annotations
|
|
16
|
+
|
|
17
|
+
import logging
|
|
18
|
+
|
|
19
|
+
import cimgraph.data_profile.cimhub_2026 as cim
|
|
20
|
+
from cimgraph.models import FeederModel
|
|
21
|
+
|
|
22
|
+
from cimhub_core import FormatExporter, GraphModel, get_base_frequency, set_base_frequency
|
|
23
|
+
from cimhub_gridlabd.exporter.glm_registry import glm_exporter_registry
|
|
24
|
+
from cimhub_gridlabd.exporter.loads.load import flush_load_accumulators
|
|
25
|
+
|
|
26
|
+
# Trigger converter registration by importing domain packages.
|
|
27
|
+
import cimhub_gridlabd.exporter.base # noqa: F401
|
|
28
|
+
import cimhub_gridlabd.exporter.lines # noqa: F401
|
|
29
|
+
import cimhub_gridlabd.exporter.switches # noqa: F401
|
|
30
|
+
import cimhub_gridlabd.exporter.transformers # noqa: F401
|
|
31
|
+
import cimhub_gridlabd.exporter.shunts # noqa: F401
|
|
32
|
+
import cimhub_gridlabd.exporter.generators # noqa: F401
|
|
33
|
+
import cimhub_gridlabd.exporter.loads # noqa: F401
|
|
34
|
+
|
|
35
|
+
_log = logging.getLogger(__name__)
|
|
36
|
+
|
|
37
|
+
__all__ = ["cim_to_glm", "cim_to_glm_json", "GlmExporter"]
|
|
38
|
+
|
|
39
|
+
|
|
40
|
+
# Conversion order: (CIM class to iterate, registry key for its converter).
|
|
41
|
+
#
|
|
42
|
+
# Most rows use the class itself as the registry key. Switch *subclasses*
|
|
43
|
+
# (Breaker, ProtectedSwitch, ...) have no converter of their own, so they route
|
|
44
|
+
# to a registered base converter. Note Breaker routes to the Recloser converter
|
|
45
|
+
# (a substation breaker is modeled as a recloser in GridLAB-D), preserving the
|
|
46
|
+
# historical hand-written behavior.
|
|
47
|
+
#
|
|
48
|
+
# Dependency rules baked into the ordering:
|
|
49
|
+
# - line/cable/impedance configs before ACLineSegment
|
|
50
|
+
# - TransformerMeshImpedance (-> transformer_configuration) before PowerTransformer
|
|
51
|
+
# - RatioTapChanger (regulator) after PowerTransformer
|
|
52
|
+
EXPORT_ORDER: list[tuple[type, type]] = [
|
|
53
|
+
# Connectivity
|
|
54
|
+
(cim.ConnectivityNode, cim.ConnectivityNode),
|
|
55
|
+
|
|
56
|
+
# Wire info (conductors) — must precede spacing and line configs
|
|
57
|
+
(cim.OverheadWireInfo, cim.OverheadWireInfo),
|
|
58
|
+
# cim.CableInfo is the abstract base of the two cable classes below and is
|
|
59
|
+
# never instantiated -- Java's DistCable likewise has no GetGLM (S04).
|
|
60
|
+
(cim.ConcentricNeutralCableInfo, cim.ConcentricNeutralCableInfo),
|
|
61
|
+
(cim.TapeShieldCableInfo, cim.TapeShieldCableInfo),
|
|
62
|
+
|
|
63
|
+
# Spacing — ConductorDistanceSpacing is the current path; WireSpacingInfo deprecated
|
|
64
|
+
(cim.ConductorDistanceSpacing, cim.ConductorDistanceSpacing),
|
|
65
|
+
(cim.WireSpacingInfo, cim.WireSpacingInfo),
|
|
66
|
+
|
|
67
|
+
# Impedance-matrix path (kept for models that use it)
|
|
68
|
+
(cim.WireAssemblyInfo, cim.WireAssemblyInfo),
|
|
69
|
+
(cim.PerLengthPhaseImpedance, cim.PerLengthPhaseImpedance),
|
|
70
|
+
(cim.PerLengthSequenceImpedance, cim.PerLengthSequenceImpedance),
|
|
71
|
+
|
|
72
|
+
# Lines — LineConfiguration emitted inline by the ACLineSegment converter
|
|
73
|
+
(cim.ACLineSegment, cim.ACLineSegment),
|
|
74
|
+
|
|
75
|
+
# Switches — reclosers (and substation breakers treated as reclosers)
|
|
76
|
+
(cim.Recloser, cim.Recloser),
|
|
77
|
+
(cim.Breaker, cim.Recloser),
|
|
78
|
+
# Fuses
|
|
79
|
+
(cim.Fuse, cim.Fuse),
|
|
80
|
+
# Other switch types route to the generic Switch converter
|
|
81
|
+
(cim.Switch, cim.Switch),
|
|
82
|
+
(cim.ProtectedSwitch, cim.Switch),
|
|
83
|
+
(cim.LoadBreakSwitch, cim.Switch),
|
|
84
|
+
(cim.Sectionaliser, cim.Switch),
|
|
85
|
+
(cim.Disconnector, cim.Switch),
|
|
86
|
+
|
|
87
|
+
# Transformers (config before the transformer that references it)
|
|
88
|
+
(cim.TransformerMeshImpedance, cim.TransformerMeshImpedance),
|
|
89
|
+
(cim.TransformerTankInfo, cim.TransformerTankInfo),
|
|
90
|
+
(cim.PowerTransformer, cim.PowerTransformer),
|
|
91
|
+
(cim.RatioTapChanger, cim.RatioTapChanger),
|
|
92
|
+
|
|
93
|
+
# Shunt devices
|
|
94
|
+
(cim.LinearShuntCompensator, cim.LinearShuntCompensator),
|
|
95
|
+
|
|
96
|
+
# Inverter-coupled DER
|
|
97
|
+
(cim.PowerElectronicsConnection, cim.PowerElectronicsConnection),
|
|
98
|
+
(cim.PhotoVoltaicUnit, cim.PhotoVoltaicUnit),
|
|
99
|
+
(cim.BatteryUnit, cim.BatteryUnit),
|
|
100
|
+
|
|
101
|
+
# Loads — accumulate-only; flush_load_accumulators() emits after the loop
|
|
102
|
+
(cim.EnergyConsumer, cim.EnergyConsumer),
|
|
103
|
+
|
|
104
|
+
# Rotating-machine DER — steady-state (EQ + SSH).
|
|
105
|
+
# Dynamics (IEC 61970-457) are a separate pass below, after EQ/SSH.
|
|
106
|
+
(cim.SynchronousMachine, cim.SynchronousMachine),
|
|
107
|
+
(cim.AsynchronousMachine, cim.AsynchronousMachine),
|
|
108
|
+
(cim.PowerElectronicsWindUnit, cim.PowerElectronicsWindUnit),
|
|
109
|
+
|
|
110
|
+
# Machine dynamics (DY) — must run AFTER the steady-state machines above so
|
|
111
|
+
# the DieselDg/WindturbDg objects already exist for dynamics to augment.
|
|
112
|
+
(cim.SynchronousMachineDynamics, cim.SynchronousMachineDynamics),
|
|
113
|
+
(cim.AsynchronousMachineDynamics, cim.AsynchronousMachineDynamics),
|
|
114
|
+
]
|
|
115
|
+
|
|
116
|
+
# --------------------------------------------------------------------------
|
|
117
|
+
# TODO: CIM classes not yet mapped to GLM converters
|
|
118
|
+
# --------------------------------------------------------------------------
|
|
119
|
+
# s223.PhysicalSpace -> house objects (ASHRAE s223 replacement for
|
|
120
|
+
# the legacy CIM house objects)
|
|
121
|
+
|
|
122
|
+
|
|
123
|
+
def _convert_class(
|
|
124
|
+
cim_class: type,
|
|
125
|
+
registry_key: type,
|
|
126
|
+
network: FeederModel,
|
|
127
|
+
glm_model: GraphModel,
|
|
128
|
+
) -> int:
|
|
129
|
+
"""Convert all instances of *cim_class* using the *registry_key* converter.
|
|
130
|
+
|
|
131
|
+
GLM converters mutate *glm_model* in place (calling ``add_to_graph``), so
|
|
132
|
+
there is no return value to collect. Returns the number of instances
|
|
133
|
+
converted, for logging.
|
|
134
|
+
"""
|
|
135
|
+
converter = glm_exporter_registry.get(registry_key)
|
|
136
|
+
if converter is None:
|
|
137
|
+
_log.warning("No converter registered for %s", registry_key.__name__)
|
|
138
|
+
return 0
|
|
139
|
+
|
|
140
|
+
try:
|
|
141
|
+
instances = network.graph.get(cim_class, {}).values()
|
|
142
|
+
except (AttributeError, TypeError):
|
|
143
|
+
return 0
|
|
144
|
+
|
|
145
|
+
count = 0
|
|
146
|
+
for obj in instances:
|
|
147
|
+
try:
|
|
148
|
+
converter(obj, glm_model)
|
|
149
|
+
count += 1
|
|
150
|
+
except Exception as e: # noqa: BLE001 — log and continue per object
|
|
151
|
+
_log.error(
|
|
152
|
+
"Failed to convert %s '%s': %s",
|
|
153
|
+
cim_class.__name__,
|
|
154
|
+
getattr(obj, "name", "?"),
|
|
155
|
+
e,
|
|
156
|
+
exc_info=True,
|
|
157
|
+
)
|
|
158
|
+
return count
|
|
159
|
+
|
|
160
|
+
|
|
161
|
+
def cim_to_glm(network: FeederModel) -> GraphModel:
|
|
162
|
+
"""Convert a CIM network to a GLM ``GraphModel``.
|
|
163
|
+
|
|
164
|
+
Iterates CIM classes in dependency order (``EXPORT_ORDER``), dispatches each
|
|
165
|
+
object to its registered converter, and returns the populated GraphModel of
|
|
166
|
+
GLM schema dataclass instances. Serialization is handled separately by
|
|
167
|
+
:class:`~cimhub_gridlabd.exporter.glm_writer.GlmJsonWriter`.
|
|
168
|
+
|
|
169
|
+
This is the implementation behind :meth:`GlmExporter.to_model`; both are
|
|
170
|
+
public and equivalent.
|
|
171
|
+
|
|
172
|
+
Args:
|
|
173
|
+
network: CIM network model (FeederModel).
|
|
174
|
+
|
|
175
|
+
Returns:
|
|
176
|
+
GraphModel containing GLM schema dataclass instances.
|
|
177
|
+
"""
|
|
178
|
+
glm_model = GraphModel()
|
|
179
|
+
|
|
180
|
+
# Carry the CIM system frequency onto the output model — converters need it
|
|
181
|
+
# for susceptance→capacitance conversions and the GLM graph has no
|
|
182
|
+
# BaseFrequency of its own.
|
|
183
|
+
set_base_frequency(glm_model, get_base_frequency(network, cim))
|
|
184
|
+
|
|
185
|
+
for cim_class, registry_key in EXPORT_ORDER:
|
|
186
|
+
count = _convert_class(cim_class, registry_key, network, glm_model)
|
|
187
|
+
if count:
|
|
188
|
+
_log.info("Converted %d %s", count, cim_class.__name__)
|
|
189
|
+
|
|
190
|
+
# Flush per-node load accumulators — must run after all EnergyConsumers
|
|
191
|
+
n_loads = flush_load_accumulators(glm_model)
|
|
192
|
+
if n_loads:
|
|
193
|
+
_log.info("Emitted %d load objects from accumulators", n_loads)
|
|
194
|
+
|
|
195
|
+
return glm_model
|
|
196
|
+
|
|
197
|
+
|
|
198
|
+
class GlmExporter(FormatExporter):
|
|
199
|
+
"""CIM → GridLAB-D exporter implementing the :class:`FormatExporter` contract.
|
|
200
|
+
|
|
201
|
+
Returns a ``GraphModel`` of GLM objects; writing is the writers' job::
|
|
202
|
+
|
|
203
|
+
glm = GlmExporter().to_model(network)
|
|
204
|
+
GlmJsonWriter().write(glm, "out.json") # GLM-JSON
|
|
205
|
+
GlmTextWriter().write(glm, "out.glm") # GLM text
|
|
206
|
+
|
|
207
|
+
:func:`cim_to_glm_json` is the convenience wrapper for the JSON form. See
|
|
208
|
+
``cimhub_core/development/CONVERTER_API.md``.
|
|
209
|
+
"""
|
|
210
|
+
|
|
211
|
+
def to_model(self, network: FeederModel, **opts) -> GraphModel:
|
|
212
|
+
"""Convert *network* to a GraphModel of GLM schema dataclasses."""
|
|
213
|
+
return cim_to_glm(network)
|
|
214
|
+
|
|
215
|
+
|
|
216
|
+
def cim_to_glm_json(network: FeederModel, output_file: str) -> None:
|
|
217
|
+
"""Convert a CIM FeederModel to a GLM-JSON file.
|
|
218
|
+
|
|
219
|
+
Convenience wrapper that calls :func:`cim_to_glm` to build the GraphModel
|
|
220
|
+
and then serializes it with
|
|
221
|
+
:class:`~cimhub_gridlabd.exporter.glm_writer.GlmJsonWriter`.
|
|
222
|
+
|
|
223
|
+
Args:
|
|
224
|
+
network: CIM network model (FeederModel).
|
|
225
|
+
output_file: Destination path for the GLM-JSON output file.
|
|
226
|
+
"""
|
|
227
|
+
from cimhub_gridlabd.exporter.glm_writer import GlmJsonWriter # noqa: PLC0415
|
|
228
|
+
|
|
229
|
+
glm_model = cim_to_glm(network)
|
|
230
|
+
writer = GlmJsonWriter()
|
|
231
|
+
writer.write(glm_model, output_file)
|
|
232
|
+
_log.info("Wrote GLM-JSON to %s", output_file)
|
|
@@ -0,0 +1,14 @@
|
|
|
1
|
+
from cimhub_gridlabd.exporter.generators.battery import convert_battery_unit
|
|
2
|
+
from cimhub_gridlabd.exporter.generators.inverter import \
|
|
3
|
+
convert_power_electronics_connection
|
|
4
|
+
from cimhub_gridlabd.exporter.generators.solar import \
|
|
5
|
+
convert_photovoltaic_unit
|
|
6
|
+
from cimhub_gridlabd.exporter.generators.machine import (
|
|
7
|
+
convert_synchronous_machine,
|
|
8
|
+
convert_asynchronous_machine,
|
|
9
|
+
convert_wind_unit,
|
|
10
|
+
)
|
|
11
|
+
from cimhub_gridlabd.exporter.generators.machine_dynamics import (
|
|
12
|
+
convert_synchronous_machine_dynamics,
|
|
13
|
+
convert_asynchronous_machine_dynamics,
|
|
14
|
+
)
|
|
@@ -0,0 +1,66 @@
|
|
|
1
|
+
"""Convert CIM BatteryUnit to a GridLAB-D battery object.
|
|
2
|
+
|
|
3
|
+
The battery object is the DC-side storage behind an inverter; its ``parent`` is
|
|
4
|
+
the inverter emitted from the owning :class:`PowerElectronicsConnection` (see
|
|
5
|
+
``inverter.py``).
|
|
6
|
+
|
|
7
|
+
CIM carries no cell chemistry, round-trip efficiency, or DC bus voltage, so
|
|
8
|
+
those come from the Java reference's hardcodes (``DistStorage.java:202-206``) and
|
|
9
|
+
are logged as X1 in ``docs/refactor/CIM_PROFILE_GAPS.md``.
|
|
10
|
+
"""
|
|
11
|
+
|
|
12
|
+
from __future__ import annotations
|
|
13
|
+
|
|
14
|
+
import logging
|
|
15
|
+
|
|
16
|
+
import cimgraph.data_profile.cimhub_2026 as cim
|
|
17
|
+
|
|
18
|
+
from cimhub_core import GraphModel
|
|
19
|
+
from cimhub_gridlabd.schema import gridlabd as glm_schema
|
|
20
|
+
from cimhub_gridlabd.exporter.glm_registry import glm_exporter_registry
|
|
21
|
+
from cimhub_gridlabd.exporter.generators.inverter import (
|
|
22
|
+
der_base_name,
|
|
23
|
+
inverter_name_for,
|
|
24
|
+
)
|
|
25
|
+
|
|
26
|
+
_log = logging.getLogger(__name__)
|
|
27
|
+
|
|
28
|
+
# DC bus voltage of the battery bank. Not the connection's ratedU, which is the
|
|
29
|
+
# AC side (DistStorage.java:202 hardcodes 48).
|
|
30
|
+
_DC_NOMINAL_VOLTAGE = 48
|
|
31
|
+
_BATTERY_TYPE = "LI_ION"
|
|
32
|
+
_ROUND_TRIP_EFFICIENCY = 0.86
|
|
33
|
+
|
|
34
|
+
|
|
35
|
+
@glm_exporter_registry.register(cim.BatteryUnit)
|
|
36
|
+
def convert_battery_unit(
|
|
37
|
+
battery_unit: cim.BatteryUnit, glm_model: GraphModel
|
|
38
|
+
) -> None:
|
|
39
|
+
"""Emit the GLM battery object for one battery unit."""
|
|
40
|
+
battery = glm_schema.Battery()
|
|
41
|
+
battery.name = f"bat_{der_base_name(battery_unit)}"
|
|
42
|
+
battery.parent = inverter_name_for(battery_unit)
|
|
43
|
+
battery.nominal_voltage = _DC_NOMINAL_VOLTAGE
|
|
44
|
+
|
|
45
|
+
# GLM battery_capacity is in watt-hours. RealEnergy's SI base is Wh, so
|
|
46
|
+
# .to("Wh") is the identity here — but state it explicitly rather than
|
|
47
|
+
# relying on the base unit, and never .to("J") (a 3600x inflation).
|
|
48
|
+
rated_e = battery_unit.ratedE
|
|
49
|
+
stored_e = battery_unit.storedE
|
|
50
|
+
battery.battery_capacity = rated_e.to("Wh") if rated_e is not None else None
|
|
51
|
+
if rated_e is not None and stored_e is not None:
|
|
52
|
+
rated_wh = rated_e.to("Wh")
|
|
53
|
+
battery.state_of_charge = stored_e.to("Wh") / rated_wh if rated_wh else None
|
|
54
|
+
|
|
55
|
+
# rated_power is the battery's power rating, max(maxP, |minP|) in the Java
|
|
56
|
+
# (DistStorage.java:86 ratedP, emitted at :207).
|
|
57
|
+
max_p = battery_unit.maxP.to("W") if battery_unit.maxP is not None else None
|
|
58
|
+
min_p = battery_unit.minP.to("W") if battery_unit.minP is not None else None
|
|
59
|
+
if max_p is not None or min_p is not None:
|
|
60
|
+
battery.rated_power = max(abs(max_p or 0.0), abs(min_p or 0.0))
|
|
61
|
+
|
|
62
|
+
battery.use_internal_battery_model = True
|
|
63
|
+
battery.battery_type = _BATTERY_TYPE
|
|
64
|
+
battery.round_trip_efficiency = _ROUND_TRIP_EFFICIENCY
|
|
65
|
+
|
|
66
|
+
glm_model.add_to_graph(battery)
|