This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -0,0 +1,570 @@
1
+ """The 1-second resistance of the pack from the current steps of normal operation, and its growth.
2
+
3
+ "1-second" names the field data's sampling interval: the value is the resistance over one
4
+ sampling interval of the record, whatever that interval is, and every output carries it.
5
+
6
+ Annex VII of Regulation (EU) 2023/1542 asks, "where possible", for the ohmic resistance
7
+ and its increase. besslib measures a DC resistance the way a current-step test does
8
+ (Barai et al., Sci. Rep. 8, 21 (2018), doi:10.1038/s41598-017-18424-5; Schweiger et al.,
9
+ Sensors 10, 5604 (2010), doi:10.3390/s100605604): the change of the terminal voltage
10
+ divided by the change of the current, over one sampling interval. Normal operation
11
+ holds many such steps (the inverter follows the load and the sun), so no test is needed.
12
+
13
+ A *current step* is a row of the step table (``besslib.soh.reduce``): two consecutive
14
+ samples whose current differs by at least ``min_step_c_rate`` x the nominal capacity,
15
+ after ``steady_s`` seconds in which the current stayed within ``steady_tolerance`` x the
16
+ step of its value before the step. ``dI`` and ``dV`` are the value after minus the value
17
+ before. Steps inside a ``mask`` interval (for example a capacity test) are left out.
18
+
19
+ Event: one calendar day in one pack-temperature band, ``a = sum dI^2``, ``b = sum dI dV``
20
+ over its steps, at the end of that day. Bands are ``temp_band_c`` wide and centred on
21
+ ``temp_ref_c + n temp_band_c``; a step's band is that of its pack temperature (lower
22
+ edge included). Steps without a temperature reading are counted and left out.
23
+
24
+ Estimate in each band: ``R = sum lambda b / sum lambda a`` over the days in memory,
25
+ ``lambda = exp(-age / tau_days)``: the least-squares slope of dV on dI through the
26
+ origin, over all steps of those days. Its statistical band is the sandwich of the
27
+ through-origin ratio fit (``besslib.soh._core``) on the day scores ``b - R a``; days are
28
+ not linked (no two days share a measurement), so it is the heteroskedasticity-consistent
29
+ form. The sensors' gain errors are added as a systematic term
30
+ (``RecordConfig.resistance_sigma``): a gain error moves every step of the record the same
31
+ way, so averaging does not reduce it. Half-width:
32
+ ``sqrt((t sigma_stat)^2 + (z resistance_sigma R)^2)``. No model of temperature is
33
+ applied; each band stands for itself, and ``headline`` marks the band centred on
34
+ ``temp_ref_c``.
35
+
36
+ Limits. At a sampling interval of about one second the value holds the ohmic part and
37
+ a part of the charge-transfer resistance: Barai et al. (2018) measured 1.35 mOhm at
38
+ 0.1 s and 1.61 mOhm at 1 s on the same 20 Ah LFP cell. It is therefore not the ohmic
39
+ resistance of an impedance spectrum, and values from records with different sampling
40
+ intervals are not comparable; every output carries the interval (``sample_s``). It is
41
+ an average over the states of charge and the currents the system visits in its band
42
+ (the resistance depends on both, Schweiger et al. 2010), not a value at a fixed state
43
+ of charge. With memory time ``tau_days`` it lags a growing resistance by about
44
+ ``tau_days``.
45
+ """
46
+
47
+ from __future__ import annotations
48
+
49
+ import math
50
+ from statistics import NormalDist
51
+
52
+ import numpy as np
53
+ import pandas as pd
54
+
55
+ from besslib.frames import PackSpec
56
+ from besslib.soh import _core, _ratio
57
+ from besslib.soh.capacity import days
58
+ from besslib.soh.config import CapacityConfig, RecordConfig, config_hash
59
+ from besslib.soh.reduce import LOOSEST_MIN_STEP_C_RATE, LOOSEST_STEADY_S, STEADY_CAP_S, STEADY_TOLERANCE, reduce_frame
60
+ from besslib.soh.rests import operating_rests
61
+
62
+ #: Columns of the day-band event table.
63
+ EVENT_COLUMNS = ["day", "temp_band_c", "t_days", "a", "b", "n_steps", "n_unrefreshed", "resistance_ohm"]
64
+
65
+ #: Columns of the estimate table.
66
+ RESISTANCE_COLUMNS = [
67
+ "time", "temp_band_c", "headline", "resistance_ohm", "resistance_ohm_low", "resistance_ohm_high",
68
+ "n_days", "n_steps", "status",
69
+ ]
70
+
71
+ def power_label(sample_s: float) -> str:
72
+ """The label of every power capability value, with the record's sampling interval."""
73
+ return f"derived from the {sample_s:g}-second resistance, not measured"
74
+
75
+ _OK = _core.STATUS_TEXT[_core.OK]
76
+ _NOT = "not possible from this data: "
77
+
78
+
79
+ def _z(level: float) -> float:
80
+ return NormalDist().inv_cdf(0.5 + level / 2.0)
81
+
82
+
83
+ def _check_setting(config: RecordConfig) -> None:
84
+ """The step table holds the steps of the loosest setting only, with a fixed steady tolerance."""
85
+ if config.min_step_c_rate < LOOSEST_MIN_STEP_C_RATE:
86
+ raise ValueError(f"min_step_c_rate below {LOOSEST_MIN_STEP_C_RATE}: the step table does not hold those steps")
87
+ if not LOOSEST_STEADY_S <= config.steady_s <= STEADY_CAP_S:
88
+ raise ValueError(f"steady_s must lie within {LOOSEST_STEADY_S} to {STEADY_CAP_S} s for the step table")
89
+ if config.steady_tolerance != STEADY_TOLERANCE:
90
+ raise ValueError(f"the step table was made with steady_tolerance {STEADY_TOLERANCE}")
91
+
92
+
93
+ def qualifying_steps(
94
+ steps: pd.DataFrame, spec: PackSpec, config: RecordConfig | None = None, mask=None
95
+ ) -> pd.DataFrame:
96
+ """The rows of a step table that qualify for ``(config.min_step_c_rate, config.steady_s)``,
97
+ outside every ``mask`` interval, with ``d_current_a`` and ``d_voltage_v`` (after - before)."""
98
+ config = config or RecordConfig()
99
+ _check_setting(config)
100
+ d_i = (steps["current_after_a"] - steps["current_before_a"]).to_numpy(float)
101
+ d_v = (steps["voltage_after_v"] - steps["voltage_before_v"]).to_numpy(float)
102
+ keep = (
103
+ (np.abs(d_i) >= config.min_step_c_rate * spec.nominal_capacity_ah)
104
+ & (steps["steady_s"].to_numpy(float) >= config.steady_s)
105
+ & np.isfinite(d_i)
106
+ & np.isfinite(d_v)
107
+ )
108
+ time = pd.DatetimeIndex(steps["time"])
109
+ for begin, end in mask or []:
110
+ keep &= ~((time >= pd.Timestamp(begin)) & (time <= pd.Timestamp(end)))
111
+ out = steps.loc[keep].copy()
112
+ out["d_current_a"] = d_i[keep]
113
+ out["d_voltage_v"] = d_v[keep]
114
+ return out
115
+
116
+
117
+ def band_centre(temp_c, temp_ref_c: float = 25.0, width_c: float = 5.0) -> np.ndarray:
118
+ """The centre of the temperature band of each temperature: ``temp_ref_c + n width_c``,
119
+ with the band ``[centre - width_c / 2, centre + width_c / 2)``. NaN stays NaN."""
120
+ t = np.asarray(temp_c, dtype=float)
121
+ return temp_ref_c + width_c * np.floor((t - temp_ref_c + 0.5 * width_c) / width_c)
122
+
123
+
124
+ def day_band_events(
125
+ steps: pd.DataFrame, spec: PackSpec, config: RecordConfig | None = None, temp_ref_c: float = 25.0, mask=None
126
+ ) -> tuple[pd.DataFrame, dict]:
127
+ """The events of the estimator: one row per calendar day and temperature band.
128
+
129
+ Columns ``day``, ``temp_band_c`` (band centre), ``t_days`` (the end of the day, days
130
+ since 2000-01-01), ``a = sum dI^2``, ``b = sum dI dV``, ``n_steps``,
131
+ ``n_unrefreshed`` (steps whose voltage did not change at all) and the day's own
132
+ ``resistance_ohm = b / a``.
133
+
134
+ A band-day is kept only when at most ``config.unrefreshed_max_share`` of its steps
135
+ show no voltage change: a current step of at least ``min_step_c_rate`` x C moves the
136
+ terminal voltage by far more than the sensor's resolution, so an exact zero means the
137
+ voltage was not refreshed together with the current, and the day's ratio would mix
138
+ real steps with steps that measure nothing.
139
+
140
+ Also returns a dict of counts: ``n_steps`` (qualifying, with a temperature),
141
+ ``n_steps_no_temperature`` and ``n_steps_masked`` (left out), ``n_days_unrefreshed``
142
+ and ``n_steps_unrefreshed_days`` (band-days left out by the rule and their steps),
143
+ ``unrefreshed_share_by_band`` (band centre -> share of its qualifying steps without
144
+ voltage change, over the record) and ``dropped`` (the band-days left out, same columns).
145
+ """
146
+ config = config or RecordConfig()
147
+ every = qualifying_steps(steps, spec, config)
148
+ use = qualifying_steps(steps, spec, config, mask)
149
+ temp = use["temp_pack_c"].to_numpy(float)
150
+ has_temp = np.isfinite(temp)
151
+ counts = {
152
+ "n_steps": int(has_temp.sum()),
153
+ "n_steps_no_temperature": int((~has_temp).sum()),
154
+ "n_steps_masked": int(len(every) - len(use)),
155
+ }
156
+ use = use.loc[has_temp]
157
+ frame = pd.DataFrame(
158
+ {
159
+ "day": pd.DatetimeIndex(use["time"]).normalize(),
160
+ "temp_band_c": band_centre(use["temp_pack_c"].to_numpy(float), temp_ref_c, config.temp_band_c),
161
+ "a": use["d_current_a"].to_numpy(float) ** 2,
162
+ "b": (use["d_current_a"] * use["d_voltage_v"]).to_numpy(float),
163
+ "n_steps": 1,
164
+ "n_unrefreshed": (use["d_voltage_v"].to_numpy(float) == 0.0).astype(int),
165
+ }
166
+ )
167
+ events = frame.groupby(["day", "temp_band_c"], sort=True, as_index=False).sum()
168
+ events["t_days"] = days(events["day"]) + 1.0
169
+ events["resistance_ohm"] = events["b"] / events["a"]
170
+ events = events[EVENT_COLUMNS]
171
+ kept = (events["n_unrefreshed"] <= config.unrefreshed_max_share * events["n_steps"]).to_numpy()
172
+ by_band = events.groupby("temp_band_c")[["n_unrefreshed", "n_steps"]].sum()
173
+ counts.update(
174
+ n_days_unrefreshed=int((~kept).sum()),
175
+ n_steps_unrefreshed_days=int(events.loc[~kept, "n_steps"].sum()),
176
+ unrefreshed_share_by_band={float(c): float(r["n_unrefreshed"] / r["n_steps"]) for c, r in by_band.iterrows()},
177
+ dropped=events.loc[~kept].reset_index(drop=True),
178
+ )
179
+ return events.loc[kept].reset_index(drop=True), counts
180
+
181
+
182
+ def _refresh_status(kept: pd.DataFrame, dropped: pd.DataFrame, tq: float, tau_days: float, min_days: float):
183
+ """The refresh status of a band whose kept days in memory are too few, or None.
184
+
185
+ The rule is the reason when the band-days it left out would have brought the band to
186
+ ``min_days`` (decayed counts with memory ``tau_days``; no forgetting for 0). X is the
187
+ share of steps without voltage change among all qualifying steps of the band in
188
+ memory, with the same weights.
189
+ """
190
+ def weighted(table):
191
+ t = table["t_days"].to_numpy(float)
192
+ use = t <= tq
193
+ lam = np.exp(-(tq - t[use]) / tau_days) if tau_days > 0 else np.ones(int(use.sum()))
194
+ return (float(lam.sum()), float((lam * table["n_steps"].to_numpy(float)[use]).sum()),
195
+ float((lam * table["n_unrefreshed"].to_numpy(float)[use]).sum()))
196
+
197
+ k_days, k_steps, k_unref = weighted(kept)
198
+ d_days, d_steps, d_unref = weighted(dropped)
199
+ if d_days <= 0.0 or k_days >= min_days or k_days + d_days < min_days:
200
+ return None
201
+ return unrefreshed_text((k_unref + d_unref) / (k_steps + d_steps))
202
+
203
+
204
+ def unrefreshed_text(share: float) -> str:
205
+ """The status of an estimate the voltage-refresh rule made impossible."""
206
+ share_text = f"{100.0 * share:.1f} % of steps show no voltage change"
207
+ return f"{_NOT}the voltage is not refreshed with the current ({share_text})"
208
+
209
+
210
+ def _status(code: int, centre: float) -> str:
211
+ if code == _core.OK:
212
+ return _OK
213
+ if code == _core.TOO_FEW_EVENTS:
214
+ return f"{_NOT}too few current steps near {centre:g} °C"
215
+ if code == _core.OUT_OF_RANGE:
216
+ return f"{_NOT}the current steps near {centre:g} °C give a resistance at or below zero"
217
+ if code == _core.SHORT_SPAN:
218
+ return f"{_NOT}the days with current steps near {centre:g} °C span too short a time for a growth rate"
219
+ return _core.STATUS_TEXT.get(code, f"{_NOT}status {code}")
220
+
221
+
222
+ def _systematic_half(stat_half: float, value: float, level: float, config: RecordConfig) -> float:
223
+ """``sqrt(stat_half^2 + (z resistance_sigma value)^2)``: the statistical half-width plus
224
+ the sensors' gain errors as a systematic term."""
225
+ return math.hypot(stat_half, _z(level) * config.resistance_sigma * value)
226
+
227
+
228
+ def _reduced(frame, spec, reduced, capacity_config):
229
+ if reduced is not None:
230
+ return reduced
231
+ if frame is None:
232
+ raise ValueError("give a frame or reduced tables")
233
+ return reduce_frame(frame, spec, capacity_config)
234
+
235
+
236
+ def estimate_resistance(
237
+ frame: pd.DataFrame | None,
238
+ spec: PackSpec,
239
+ temp_ref_c: float = 25.0,
240
+ level: float = 0.90,
241
+ *,
242
+ config: RecordConfig | None = None,
243
+ capacity_config: CapacityConfig | None = None,
244
+ reduced=None,
245
+ at=None,
246
+ mask=None,
247
+ ) -> pd.DataFrame:
248
+ """The 1-second resistance with its band, per temperature band, at each time in ``at`` (module docstring).
249
+
250
+ Parameters
251
+ ----------
252
+ frame
253
+ Operating data in the besslib frame format; may be ``None`` when ``reduced`` is given.
254
+ spec
255
+ The pack; its nominal capacity sets the smallest current step.
256
+ temp_ref_c
257
+ Centre of the headline band.
258
+ level
259
+ Band level.
260
+ config, capacity_config
261
+ Settings of the record and of the reduction; defaults are the frozen ones.
262
+ reduced
263
+ A ``reduce.Reduced`` of the record (its step table is used).
264
+ at
265
+ Times of the estimate. Default: the end of every calendar month in the data.
266
+ mask
267
+ Intervals ``(start, end)`` whose steps are left out.
268
+
269
+ Returns
270
+ -------
271
+ DataFrame, one row per time and temperature band (every band with at least one day,
272
+ and always the headline band): ``time``, ``temp_band_c`` (band centre), ``headline``,
273
+ ``resistance_ohm`` with ``_low`` and ``_high`` (statistical and systematic part),
274
+ ``n_days`` and ``n_steps`` (in memory, decayed), ``status``. A value is given only
275
+ when the status is ``estimated``. When a band has too few days in memory because the
276
+ voltage-refresh rule left band-days out (they would have brought it to
277
+ ``resistance_min_days``), the status says so, with the share of steps without voltage
278
+ change among the band's qualifying steps in memory (decayed weights). ``attrs``:
279
+ ``config_hash``, ``capacity_config_hash``, ``sample_s``, ``events`` (the kept
280
+ day-band table) and the counts of ``day_band_events`` (``dropped``,
281
+ ``n_days_unrefreshed``, ``unrefreshed_share_by_band``, ...).
282
+ """
283
+ config = config or RecordConfig()
284
+ capacity_config = capacity_config or CapacityConfig()
285
+ reduced = _reduced(frame, spec, reduced, capacity_config)
286
+ events, counts = day_band_events(reduced.steps, spec, config, temp_ref_c, mask)
287
+ if at is None:
288
+ known = pd.DatetimeIndex(reduced.daily["day"]) if len(reduced.daily) else pd.DatetimeIndex([])
289
+ if len(known) == 0:
290
+ raise ValueError("no data to estimate from")
291
+ at = pd.date_range(known.min(), known.max() + pd.Timedelta(days=1), freq="ME")
292
+ at = pd.DatetimeIndex(at)
293
+ at_days = days(at)
294
+ dropped = counts["dropped"]
295
+ bands = sorted(set(events["temp_band_c"].tolist()) | set(dropped["temp_band_c"].tolist()) | {float(temp_ref_c)})
296
+ rows = []
297
+ for centre in bands:
298
+ sel = events[events["temp_band_c"] == centre]
299
+ sel_dropped = dropped[dropped["temp_band_c"] == centre]
300
+ t = sel["t_days"].to_numpy(float)
301
+ n_steps = sel["n_steps"].to_numpy(float)
302
+ est = _ratio.estimate_ratio(
303
+ t, sel["a"].to_numpy(float), sel["b"].to_numpy(float), np.zeros(len(sel), dtype=int), at_days,
304
+ config.tau_days, level, config.resistance_min_days, 0.0, math.inf,
305
+ )
306
+ for k, (when, tq) in enumerate(zip(at, at_days)):
307
+ e = est.iloc[k]
308
+ use = t <= tq
309
+ lam = np.exp(-(tq - t[use]) / config.tau_days) if config.tau_days > 0 else np.ones(int(use.sum()))
310
+ row = {
311
+ "time": when, "temp_band_c": float(centre), "headline": bool(centre == float(temp_ref_c)),
312
+ "resistance_ohm": math.nan, "resistance_ohm_low": math.nan, "resistance_ohm_high": math.nan,
313
+ "n_days": float(e["n_events"]), "n_steps": float((lam * n_steps[use]).sum()),
314
+ "status": _status(int(e["status"]), centre),
315
+ }
316
+ if int(e["status"]) == _core.TOO_FEW_EVENTS:
317
+ refresh = _refresh_status(sel, sel_dropped, tq, config.tau_days, config.resistance_min_days)
318
+ row["status"] = refresh or row["status"]
319
+ if int(e["status"]) == _core.OK:
320
+ r = float(e["value"])
321
+ half = _systematic_half(float(e["high"]) - r, r, level, config)
322
+ row.update(resistance_ohm=r, resistance_ohm_low=r - half, resistance_ohm_high=r + half)
323
+ rows.append(row)
324
+ out = pd.DataFrame(rows, columns=RESISTANCE_COLUMNS)
325
+ out.attrs.update(
326
+ config_hash=config_hash(config),
327
+ capacity_config_hash=config_hash(capacity_config),
328
+ sample_s=float(reduced.sample_s),
329
+ events=events,
330
+ **counts,
331
+ )
332
+ return out
333
+
334
+
335
+ def _delta_half(grad, cov, k_t: float) -> float:
336
+ """``k_t sqrt(grad' cov grad)``; NaN when that variance is negative (the sandwich is not
337
+ positive by construction)."""
338
+ var = 0.0
339
+ for r in range(2):
340
+ for s in range(2):
341
+ var += grad[r] * cov[r][s] * grad[s]
342
+ return k_t * math.sqrt(var) if var >= 0.0 else math.nan
343
+
344
+
345
+ def resistance_growth(
346
+ frame: pd.DataFrame | None,
347
+ spec: PackSpec,
348
+ temp_ref_c: float = 25.0,
349
+ level: float = 0.90,
350
+ *,
351
+ config: RecordConfig | None = None,
352
+ capacity_config: CapacityConfig | None = None,
353
+ reduced=None,
354
+ at=None,
355
+ mask=None,
356
+ ) -> dict:
357
+ """The growth of the 1-second resistance over the whole record, and the remaining power capability.
358
+
359
+ Fit: ``R = k0 + k1 y`` over every kept day of the headline band (``day_band_events``:
360
+ band-days whose voltage was not refreshed with the current are left out) up to ``at`` (default: the
361
+ end of the record's last day), no forgetting, ``y`` in years since the first day with
362
+ a step in that band (the through-origin growth fit of ``besslib.soh._core``: ``b =
363
+ (k0 + k1 y) a``, the lag-1 sandwich without links, Student-t quantile). It needs days
364
+ spanning ``growth_min_span_years``.
365
+
366
+ ``growth_percent_per_year = 100 k1 / k0``, the growth as a share of the start value.
367
+ ``power_capability_share = k0 / (k0 + k1 y_at)``: the share of the start power
368
+ capability that remains at ``at``, *derived from the resistance over one sampling
369
+ interval, not measured* (``power_capability_label`` names the interval). Reason:
370
+ with an ohmic model the power a pack can give at a fixed voltage limit is ``V_lim
371
+ (OCV - V_lim) / R``, proportional to ``1 / R`` (Regulation (EU) 2023/1542, Annex IV
372
+ (4), defines the power fade by that power). Both bands are by
373
+ the delta method from the fit's covariance, with the t quantile; a negative
374
+ delta-method variance gives no band (status). A constant gain error of either sensor
375
+ scales ``k0`` and ``k1`` by the same factor and cancels in both ratios, so no
376
+ systematic term is added to them.
377
+
378
+ Both ratios are linearised around their denominators, ``k0`` and ``R_at = k0 + k1
379
+ y_at``. When the band of either reaches zero or below, the ratio has no finite
380
+ variance and its linear band means nothing (a share band below zero, a growth band of
381
+ thousands of per cent); the status is then *not possible*, with the reason, and no
382
+ ratio is given. This happens when a straight line is a poor model of the record, for
383
+ example when the resistance triples, or when the voltage signal changes its timing
384
+ within the record.
385
+
386
+ ``power_capability_w = V_min (OCV - V_min) / R_at`` with ``V_min = spec.voltage_min_v``
387
+ (the pack's lower voltage limit), ``R_at = k0 + k1 y_at``, and the open-circuit
388
+ voltage of the last ``full`` rest before ``at`` (``rests.operating_rests``): the
389
+ discharge power at full charge at which the terminal voltage would reach the limit.
390
+ It has its own status; without ``spec.voltage_min_v`` it is not computed. Its band
391
+ holds the statistical part of ``R_at`` (t quantile), the open-circuit voltage's own
392
+ uncertainty (``ocv_sigma_v``, normal quantile) and the gain errors as a systematic
393
+ term: relative ``sqrt(sigma_I^2 + (sigma_V V_min / (OCV - V_min))^2)``, because a
394
+ voltage gain error scales the open-circuit voltage and the resistance alike.
395
+
396
+ Returns a dict: ``resistance_start_ohm`` (``k0``), ``resistance_at_ohm``,
397
+ ``growth_percent_per_year`` with ``_low`` and ``_high``, ``power_capability_share``
398
+ with ``_low`` and ``_high``, ``power_capability_w`` with ``_low``, ``_high`` and
399
+ ``power_capability_w_status``, ``power_capability_label``, ``temp_band_c``,
400
+ ``first_day``, ``at``, ``n_days``, ``n_days_unrefreshed`` (band-days left out by the
401
+ voltage-refresh rule), ``span_years``, ``dof``, ``status``, ``sample_s``,
402
+ ``config_hash``, ``capacity_config_hash``.
403
+ """
404
+ config = config or RecordConfig()
405
+ capacity_config = capacity_config or CapacityConfig()
406
+ reduced = _reduced(frame, spec, reduced, capacity_config)
407
+ events, counts = day_band_events(reduced.steps, spec, config, temp_ref_c, mask)
408
+ sel = events[events["temp_band_c"] == float(temp_ref_c)]
409
+ sel_dropped = counts["dropped"][counts["dropped"]["temp_band_c"] == float(temp_ref_c)]
410
+ nan = math.nan
411
+ out = {
412
+ "resistance_start_ohm": nan, "resistance_at_ohm": nan,
413
+ "growth_percent_per_year": nan, "growth_percent_per_year_low": nan, "growth_percent_per_year_high": nan,
414
+ "power_capability_share": nan, "power_capability_share_low": nan, "power_capability_share_high": nan,
415
+ "power_capability_w": nan, "power_capability_w_low": nan, "power_capability_w_high": nan,
416
+ "power_capability_w_status": f"{_NOT}no growth fit",
417
+ "power_capability_label": power_label(float(reduced.sample_s)),
418
+ "temp_band_c": float(temp_ref_c), "first_day": pd.NaT, "at": pd.NaT,
419
+ "n_days": 0.0, "n_days_unrefreshed": 0, "span_years": 0.0, "dof": 0.0,
420
+ "status": _status(_core.TOO_FEW_EVENTS, float(temp_ref_c)),
421
+ "sample_s": float(reduced.sample_s),
422
+ "config_hash": config_hash(config), "capacity_config_hash": config_hash(capacity_config),
423
+ }
424
+ if at is None:
425
+ known = pd.DatetimeIndex(reduced.daily["day"]) if len(reduced.daily) else pd.DatetimeIndex([])
426
+ if len(known) == 0:
427
+ raise ValueError("no data to estimate from")
428
+ at = known.max() + pd.Timedelta(days=1)
429
+ at = pd.Timestamp(at)
430
+ out["at"] = at
431
+ tq = float(days([at])[0])
432
+ sel = sel[sel["t_days"] <= tq]
433
+ sel_dropped = sel_dropped[sel_dropped["t_days"] <= tq]
434
+ out["n_days_unrefreshed"] = int(len(sel_dropped))
435
+ refresh = _refresh_status(sel, sel_dropped, tq, 0.0, config.resistance_min_days)
436
+ if len(sel) == 0:
437
+ out["status"] = refresh or out["status"]
438
+ return out
439
+ t = sel["t_days"].to_numpy(float)
440
+ t0 = float(t[0])
441
+ out["first_day"] = pd.Timestamp(sel["day"].iloc[0])
442
+ fit = _ratio.estimate_growth(
443
+ t, sel["a"].to_numpy(float), sel["b"].to_numpy(float), np.zeros(len(sel), dtype=int), t0, tq, level,
444
+ config.resistance_min_days, config.growth_min_span_years, 0.0, math.inf,
445
+ )
446
+ code = int(fit["status"])
447
+ out.update(n_days=float(fit["n_events"]), span_years=float(fit["span_years"]), dof=float(fit["dof"]),
448
+ status=_status(code, float(temp_ref_c)))
449
+ if code == _core.TOO_FEW_EVENTS:
450
+ out["status"] = refresh or out["status"]
451
+ if code != _core.OK:
452
+ return out
453
+ k0, k1, cov = float(fit["k0"]), float(fit["k1"]), fit["cov"]
454
+ y = (tq - t0) / 365.25
455
+ r_at = k0 + k1 * y
456
+ k_t = _core.t_quantile(_z(level), float(fit["dof"]))
457
+ growth = k1 / k0
458
+ growth_half = _delta_half((-k1 / k0**2, 1.0 / k0), cov, k_t)
459
+ share = k0 / r_at
460
+ share_half = _delta_half((k1 * y / r_at**2, -k0 * y / r_at**2), cov, k_t)
461
+ k0_half = _delta_half((1.0, 0.0), cov, k_t)
462
+ r_at_half = _delta_half((1.0, y), cov, k_t)
463
+ if not (k0 - k0_half > 0.0 and r_at - r_at_half > 0.0):
464
+ out["status"] = (f"{_NOT}the growth fit near {float(temp_ref_c):g} °C does not separate the resistance "
465
+ "at the start or at the date from zero")
466
+ return out
467
+ if math.isnan(growth_half) or math.isnan(share_half):
468
+ out["status"] = _core.STATUS_TEXT[_core.NO_BAND]
469
+ return out
470
+ out.update(
471
+ resistance_start_ohm=k0,
472
+ resistance_at_ohm=r_at,
473
+ growth_percent_per_year=100.0 * growth,
474
+ growth_percent_per_year_low=100.0 * (growth - growth_half),
475
+ growth_percent_per_year_high=100.0 * (growth + growth_half),
476
+ power_capability_share=share,
477
+ power_capability_share_low=share - share_half,
478
+ power_capability_share_high=share + share_half,
479
+ )
480
+ out.update(_power_w(reduced, spec, capacity_config, config, mask, at, r_at, (1.0, y), cov, k_t, level))
481
+ return out
482
+
483
+
484
+ def _power_w(reduced, spec, capacity_config, config, mask, at, r_at, grad, cov, k_t, level) -> dict:
485
+ """``power_capability_w`` with its band and status (see ``resistance_growth``)."""
486
+ nan = math.nan
487
+ out = {"power_capability_w": nan, "power_capability_w_low": nan, "power_capability_w_high": nan}
488
+ v_min = spec.voltage_min_v
489
+ if v_min is None:
490
+ out["power_capability_w_status"] = f"{_NOT}voltage limits not given"
491
+ return out
492
+ rests = operating_rests(reduced.rests, spec, capacity_config, mask)
493
+ full = rests[(rests["kind"] == "full") & (rests["start"] <= at) & np.isfinite(rests["ocv_v"].to_numpy(float))]
494
+ if len(full) == 0:
495
+ out["power_capability_w_status"] = f"{_NOT}no full rest before the date"
496
+ return out
497
+ last = full.sort_values("start").iloc[-1]
498
+ ocv = float(last["ocv_v"])
499
+ ocv_sigma = float(last["ocv_sigma_v"]) if np.isfinite(last["ocv_sigma_v"]) else 0.0
500
+ if not ocv > v_min:
501
+ out["power_capability_w_status"] = f"{_NOT}the open-circuit voltage at full charge is not above the lower limit"
502
+ return out
503
+ power = v_min * (ocv - v_min) / r_at
504
+ r_half = _delta_half(grad, cov, k_t)
505
+ if math.isnan(r_half):
506
+ out["power_capability_w_status"] = _core.STATUS_TEXT[_core.NO_BAND]
507
+ return out
508
+ z = _z(level)
509
+ sigma_i = config.current_accuracy / math.sqrt(3.0)
510
+ sigma_v = config.voltage_accuracy / math.sqrt(3.0)
511
+ rel_sys = math.hypot(sigma_i, sigma_v * v_min / (ocv - v_min))
512
+ half = math.sqrt((power / r_at * r_half) ** 2 + (z * v_min / r_at * ocv_sigma) ** 2 + (z * rel_sys * power) ** 2)
513
+ out.update(
514
+ power_capability_w=power,
515
+ power_capability_w_low=power - half,
516
+ power_capability_w_high=power + half,
517
+ power_capability_w_status=_OK,
518
+ )
519
+ return out
520
+
521
+
522
+ def resistance_of_steps(steps: pd.DataFrame, spec: PackSpec, config: RecordConfig | None = None) -> dict:
523
+ """The same estimator on any short window: ``R = sum dI dV / sum dI^2`` over the qualifying rows of ``steps``.
524
+
525
+ For a window too short for days, such as the first minute of a capacity test. Each
526
+ step is one event of the through-origin fit, so with two steps or more the
527
+ statistical band is the heteroskedasticity-consistent sandwich over the steps, with
528
+ the t quantile on ``n_steps - 1`` degrees of freedom; one step gives no scatter, and
529
+ the band then holds the systematic term only (``band`` says which). The
530
+ voltage-refresh rule of ``day_band_events`` applies to the window as to a day: when
531
+ more than ``config.unrefreshed_max_share`` of its steps show no voltage change, no
532
+ value is given. Returns ``resistance_ohm`` with ``_low`` and ``_high``, ``n_steps``,
533
+ ``n_unrefreshed``, ``band`` (``"statistical and systematic"`` or ``"systematic only:
534
+ one step"``) and ``status``.
535
+ """
536
+ config = config or RecordConfig()
537
+ use = qualifying_steps(steps, spec, config)
538
+ d_i = use["d_current_a"].to_numpy(float)
539
+ d_v = use["d_voltage_v"].to_numpy(float)
540
+ n = int(len(use))
541
+ nan = math.nan
542
+ n_unref = int((d_v == 0.0).sum())
543
+ out = {"resistance_ohm": nan, "resistance_ohm_low": nan, "resistance_ohm_high": nan, "n_steps": n,
544
+ "n_unrefreshed": n_unref, "band": ""}
545
+ if n == 0:
546
+ out["status"] = f"{_NOT}no qualifying current step"
547
+ return out
548
+ if n_unref > config.unrefreshed_max_share * n:
549
+ out["status"] = unrefreshed_text(n_unref / n)
550
+ return out
551
+ a = d_i * d_i
552
+ b = d_i * d_v
553
+ r = float(b.sum() / a.sum())
554
+ if not r > 0.0:
555
+ out["status"] = f"{_NOT}the current steps give a resistance at or below zero"
556
+ return out
557
+ stat_half = 0.0
558
+ out["band"] = "systematic only: one step"
559
+ if n >= 2:
560
+ # Ordered placeholder times: the fit has no forgetting here, so only the order matters.
561
+ e = _ratio.estimate_ratio(np.arange(n, dtype=float), a, b, np.zeros(n, dtype=int), [float(n)], 0.0,
562
+ config.level, 2.0, 0.0, math.inf).iloc[0]
563
+ if int(e["status"]) != _core.OK:
564
+ out["status"] = _status(int(e["status"]), nan)
565
+ return out
566
+ stat_half = float(e["high"]) - r
567
+ out["band"] = "statistical and systematic"
568
+ half = _systematic_half(stat_half, r, config.level, config)
569
+ out.update(resistance_ohm=r, resistance_ohm_low=r - half, resistance_ohm_high=r + half, status=_OK)
570
+ return out