DLMS-SPODES 0.87.16__py3-none-any.whl → 0.88.1__py3-none-any.whl

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (103) hide show
  1. DLMS_SPODES/Values/EN/__init__.py +1 -1
  2. DLMS_SPODES/Values/EN/actors.py +8 -8
  3. DLMS_SPODES/Values/EN/relation_to_obis_names.py +387 -387
  4. DLMS_SPODES/Values/RU/__init__.py +1 -1
  5. DLMS_SPODES/Values/RU/actors.py +8 -8
  6. DLMS_SPODES/Values/RU/relation_to_obis_names.py +396 -396
  7. DLMS_SPODES/__init__.py +6 -6
  8. DLMS_SPODES/configEN.ini +126 -126
  9. DLMS_SPODES/config_parser.py +53 -53
  10. DLMS_SPODES/cosem_interface_classes/Overview/__init__.py +0 -0
  11. DLMS_SPODES/cosem_interface_classes/Overview/class_id.py +107 -0
  12. DLMS_SPODES/cosem_interface_classes/__class_init__.py +3 -3
  13. DLMS_SPODES/cosem_interface_classes/__init__.py +3 -2
  14. DLMS_SPODES/cosem_interface_classes/activity_calendar.py +210 -254
  15. DLMS_SPODES/cosem_interface_classes/arbitrator.py +78 -105
  16. DLMS_SPODES/cosem_interface_classes/association_ln/abstract.py +50 -34
  17. DLMS_SPODES/cosem_interface_classes/association_ln/authentication_mechanism_name.py +25 -25
  18. DLMS_SPODES/cosem_interface_classes/association_ln/mechanism_id.py +25 -25
  19. DLMS_SPODES/cosem_interface_classes/association_ln/method.py +5 -5
  20. DLMS_SPODES/cosem_interface_classes/association_ln/ver0.py +440 -485
  21. DLMS_SPODES/cosem_interface_classes/association_ln/ver1.py +126 -133
  22. DLMS_SPODES/cosem_interface_classes/association_ln/ver2.py +30 -36
  23. DLMS_SPODES/cosem_interface_classes/association_ln/ver3.py +3 -4
  24. DLMS_SPODES/cosem_interface_classes/association_sn/ver0.py +14 -12
  25. DLMS_SPODES/cosem_interface_classes/clock.py +81 -131
  26. DLMS_SPODES/cosem_interface_classes/collection.py +2106 -2122
  27. DLMS_SPODES/cosem_interface_classes/cosem_interface_class.py +525 -583
  28. DLMS_SPODES/cosem_interface_classes/data.py +12 -21
  29. DLMS_SPODES/cosem_interface_classes/demand_register/ver0.py +32 -59
  30. DLMS_SPODES/cosem_interface_classes/disconnect_control.py +56 -74
  31. DLMS_SPODES/cosem_interface_classes/extended_register.py +18 -27
  32. DLMS_SPODES/cosem_interface_classes/gprs_modem_setup.py +33 -43
  33. DLMS_SPODES/cosem_interface_classes/gsm_diagnostic/ver0.py +78 -103
  34. DLMS_SPODES/cosem_interface_classes/gsm_diagnostic/ver1.py +42 -40
  35. DLMS_SPODES/cosem_interface_classes/gsm_diagnostic/ver2.py +6 -9
  36. DLMS_SPODES/cosem_interface_classes/iec_hdlc_setup/ver0.py +11 -11
  37. DLMS_SPODES/cosem_interface_classes/iec_hdlc_setup/ver1.py +27 -53
  38. DLMS_SPODES/cosem_interface_classes/iec_local_port_setup.py +9 -11
  39. DLMS_SPODES/cosem_interface_classes/image_transfer/image_transfer_status.py +15 -15
  40. DLMS_SPODES/cosem_interface_classes/image_transfer/ver0.py +54 -126
  41. DLMS_SPODES/cosem_interface_classes/implementations/__init__.py +3 -3
  42. DLMS_SPODES/cosem_interface_classes/implementations/arbitrator.py +19 -19
  43. DLMS_SPODES/cosem_interface_classes/implementations/data.py +491 -487
  44. DLMS_SPODES/cosem_interface_classes/implementations/profile_generic.py +85 -83
  45. DLMS_SPODES/cosem_interface_classes/ipv4_setup.py +42 -72
  46. DLMS_SPODES/cosem_interface_classes/limiter.py +77 -111
  47. DLMS_SPODES/cosem_interface_classes/ln_pattern.py +334 -333
  48. DLMS_SPODES/cosem_interface_classes/modem_configuration/ver0.py +51 -65
  49. DLMS_SPODES/cosem_interface_classes/modem_configuration/ver1.py +27 -39
  50. DLMS_SPODES/cosem_interface_classes/ntp_setup/ver0.py +48 -67
  51. DLMS_SPODES/cosem_interface_classes/obis.py +28 -23
  52. DLMS_SPODES/cosem_interface_classes/overview.py +198 -197
  53. DLMS_SPODES/cosem_interface_classes/parameter.py +548 -547
  54. DLMS_SPODES/cosem_interface_classes/parameters.py +172 -172
  55. DLMS_SPODES/cosem_interface_classes/profile_generic/ver0.py +90 -122
  56. DLMS_SPODES/cosem_interface_classes/profile_generic/ver1.py +268 -277
  57. DLMS_SPODES/cosem_interface_classes/push_setup/ver0.py +13 -12
  58. DLMS_SPODES/cosem_interface_classes/push_setup/ver1.py +9 -10
  59. DLMS_SPODES/cosem_interface_classes/push_setup/ver2.py +124 -166
  60. DLMS_SPODES/cosem_interface_classes/register.py +18 -45
  61. DLMS_SPODES/cosem_interface_classes/register_activation/ver0.py +45 -80
  62. DLMS_SPODES/cosem_interface_classes/register_monitor.py +33 -46
  63. DLMS_SPODES/cosem_interface_classes/reports.py +72 -70
  64. DLMS_SPODES/cosem_interface_classes/schedule.py +88 -176
  65. DLMS_SPODES/cosem_interface_classes/script_table.py +54 -87
  66. DLMS_SPODES/cosem_interface_classes/security_setup/ver0.py +45 -68
  67. DLMS_SPODES/cosem_interface_classes/security_setup/ver1.py +122 -158
  68. DLMS_SPODES/cosem_interface_classes/single_action_schedule.py +34 -50
  69. DLMS_SPODES/cosem_interface_classes/special_days_table.py +54 -84
  70. DLMS_SPODES/cosem_interface_classes/tcp_udp_setup.py +20 -42
  71. DLMS_SPODES/cosem_pdu.py +93 -93
  72. DLMS_SPODES/enums.py +625 -625
  73. DLMS_SPODES/exceptions.py +106 -106
  74. DLMS_SPODES/firmwares.py +99 -99
  75. DLMS_SPODES/hdlc/frame.py +875 -875
  76. DLMS_SPODES/hdlc/sub_layer.py +54 -54
  77. DLMS_SPODES/literals.py +17 -17
  78. DLMS_SPODES/obis/__init__.py +1 -1
  79. DLMS_SPODES/obis/media_id.py +931 -931
  80. DLMS_SPODES/pardata.py +22 -22
  81. DLMS_SPODES/pdu_enums.py +98 -98
  82. DLMS_SPODES/relation_to_OBIS.py +463 -465
  83. DLMS_SPODES/settings.py +551 -551
  84. DLMS_SPODES/types/choices.py +140 -142
  85. DLMS_SPODES/types/common_data_types.py +2379 -2401
  86. DLMS_SPODES/types/cosem_service_types.py +109 -109
  87. DLMS_SPODES/types/implementations/arrays.py +25 -25
  88. DLMS_SPODES/types/implementations/bitstrings.py +97 -97
  89. DLMS_SPODES/types/implementations/double_long_usingneds.py +35 -35
  90. DLMS_SPODES/types/implementations/enums.py +57 -57
  91. DLMS_SPODES/types/implementations/integers.py +12 -11
  92. DLMS_SPODES/types/implementations/long_unsigneds.py +127 -127
  93. DLMS_SPODES/types/implementations/octet_string.py +11 -11
  94. DLMS_SPODES/types/implementations/structs.py +64 -64
  95. DLMS_SPODES/types/type_alias.py +74 -0
  96. DLMS_SPODES/types/useful_types.py +627 -677
  97. {dlms_spodes-0.87.16.dist-info → dlms_spodes-0.88.1.dist-info}/METADATA +30 -30
  98. dlms_spodes-0.88.1.dist-info/RECORD +118 -0
  99. {dlms_spodes-0.87.16.dist-info → dlms_spodes-0.88.1.dist-info}/WHEEL +1 -1
  100. DLMS_SPODES/cosem_interface_classes/a_parameter.py +0 -20
  101. DLMS_SPODES/cosem_interface_classes/attr_indexes.py +0 -12
  102. dlms_spodes-0.87.16.dist-info/RECORD +0 -117
  103. {dlms_spodes-0.87.16.dist-info → dlms_spodes-0.88.1.dist-info}/top_level.txt +0 -0
DLMS_SPODES/__init__.py CHANGED
@@ -1,6 +1,6 @@
1
- from . import settings
2
- from .cosem_interface_classes import collection
3
- from importlib.metadata import version
4
- from .pardata import ParData
5
-
6
- __version__ = version("DLMS_SPODES")
1
+ from . import settings
2
+ from .cosem_interface_classes import collection
3
+ from importlib.metadata import version
4
+ from .pardata import ParData
5
+
6
+ __version__ = version("DLMS_SPODES")
DLMS_SPODES/configEN.ini CHANGED
@@ -1,126 +1,126 @@
1
- [values.common]
2
- reserved = reserved
3
-
4
- [values.prefix]
5
- kilo = k
6
-
7
- [values.enum]
8
- # cdt.units
9
- time_year = a
10
- time_month = mo
11
- time_week = wk
12
- time_day = d
13
- time_hour = h
14
- time_minute = min
15
- time_second = s
16
- phase_angle_degree = °
17
- temperature = °c
18
- local_currency = currency
19
- length_metre = m
20
- speed_metre_per_second = m/s
21
- volume_value_cubic_metre = m³
22
- corrected_volume_cubic_metre = m³*
23
- volume_flux_cubic_metre_per_hour = m³/h
24
- corrected_volume_flux_cubic_metre_per_hour = m³/h*
25
- volume_flux_cubic_metre_per_day = m³/d
26
- corrected_volume_flux_cubic_metre_per_day = m³/d
27
- volume_litre = l
28
- mass_kilogram = kg
29
- force_newton = n
30
- energy_newton_meter = nm
31
- pressure_pascal = pa
32
- pressure_bar = bar
33
- energy_joule = j
34
- thermal_power_rate_of_change_joule_per_hour = j/h
35
- active_power_watt = w
36
- apparent_power_volt_ampere = va
37
- reactive_power_var = var
38
- active_energy_value_watt_hour = wh
39
- apparent_energy_value_volt_ampere_hour = vah
40
- reactive_energy_value_var_hour = varh
41
- current_ampere = a
42
- electrical_charge_coulomb = c
43
- voltage_volt = v
44
- electric_field_strength_volt_per_metre = v/m
45
- capacitance_farad = f
46
- resistance_ohm = ω
47
- resistivity = ωm²/m
48
- magnetic_flux_weber = wb
49
- magnetic_flux_density_tesla = t
50
- magnetic_field_strength_ampere_per_metre = a/m
51
- inductance_henry = h
52
- frequency_hertz = hz
53
- rw_active_energy_value = 1/(wh)
54
- rb_reactive_energy_value = 1/(varh)
55
- rs_apparent_energy_value = 1/(vah)
56
- volt_squared_hour_volt_squared_hour_meter = v²h
57
- ampere_squared_hour = a²h
58
- mass_flux_kilogram_per_second = kg/s
59
- conductance_siemens = s, mho
60
- temperature_kelvin = k
61
- ru2h_volt_squared_hour_meter = 1/(v²h)
62
- ri2h_ampere_squared_hour_meter = 1/(a²h)
63
- rv_meter = 1/m³
64
- percentage = %%
65
- ampere_hours = ah
66
- energy_per_volume = wh/m³
67
- calorific_value_wobbe = j/m³
68
- molar_fraction_of_gas_composition_mole_percent = mol %%
69
- mass_density_quantity_of_material = g/m³
70
- dynamic_viscosity_pascal_second = pa s
71
- specific_energy_joule_kilogram = j/kg
72
- pressure_gram_per_square_centimeter = g/cm²
73
- pressure_atmosphere = atm
74
- signal_strength_milliwatt = dbm
75
- signal_strength_microvolt = dbµv
76
- logarithmic_unit = db
77
- length_inch = in
78
- length_foot = ft
79
- mass_pound = lb
80
- temperature_fahrenheit = °f
81
- temperature_rankine = °r
82
- area_square_inch = sq. in
83
- area_square_foot = sq ft
84
- area_acre = ac
85
- volume_cubic_inch = cu in
86
- volume_cubic_foot = cu ft
87
- volume_acre_foot = ac ft
88
- volume_gallon_imperial = gal(imp)
89
- volume_gallon_us = gal(us)
90
- force_pound_force = lbf
91
- pressure_pound_force_per_square_inch = psi
92
- density_pound_per_cubic_foot = lb/cu ft
93
- dynamic_viscosity = lb/(ft .s)
94
- kinematic_viscosity_square_foot_per_second = sq ft/s
95
- energy_british_thermal_unit = btu
96
- energy_therm_eu = thm(ec)
97
- energy_therm_us = thm(us)
98
- calorific_value_of_mass_lenthalpy = btu/lb
99
- calorific_value_of_volume_wobbe = btu/cu ft
100
- volume_meter_cubic_feet_rv = cu ft rv
101
- speed_foot_per_second = ft/s
102
- volume_flux_cubic_foot_per_second = cu ft/s
103
- volume_flux_cubic_foot_per_min = cu ft/min
104
- volume_flux_cubic_foot_per_hour = cu ft/h
105
- volume_flux_cubic_foot_per_day = cu ft/d
106
- volume_flux_acre_foot_per_second = ac ft/s
107
- volume_flux_acre_foot_per_min = ac ft/min
108
- volume_flux_acre_foot_per_hour = ac ft/h
109
- volume_flux_acre_foot_per_day = ac ft/d
110
- volume_imperial_gallon_meter_rv = gal(imp) rv
111
- volume_flux_imperial_gallon_per_second = gal(imp)/s
112
- volume_flux_imperial_gallon_per_min = gal(imp)/min
113
- volume_flux_imperial_gallon_per_hour = gal(imp)/h
114
- volume_flux_imperial_gallon_per_day = gal(imp)/d
115
- volume_us_gallon_rv = gal(us) rv
116
- volume_flux_us_gallon_per_second = gal(us)/s
117
- volume_flux_us_gallon_per_min = gal(us)/min
118
- volume_flux_us_gallon_per_hour = gal(us)/h
119
- volume_flux_us_gallon_per_day = gal(us)/d
120
- energy_flow_british_thermal_unit_per_second = btu/s
121
- energy_flow_british_thermal_unit_per_minute = btu/min
122
- energy_flow_british_thermal_unit_per_hour = btu/h
123
- energy_flow_british_thermal_unit_per_day = btu/d
124
- extended_table_of_units = extended
125
- other_unit = other
126
- no_unit_unitless_count = count
1
+ [values.common]
2
+ reserved = reserved
3
+
4
+ [values.prefix]
5
+ kilo = k
6
+
7
+ [values.enum]
8
+ # cdt.units
9
+ time_year = a
10
+ time_month = mo
11
+ time_week = wk
12
+ time_day = d
13
+ time_hour = h
14
+ time_minute = min
15
+ time_second = s
16
+ phase_angle_degree = °
17
+ temperature = °c
18
+ local_currency = currency
19
+ length_metre = m
20
+ speed_metre_per_second = m/s
21
+ volume_value_cubic_metre = m³
22
+ corrected_volume_cubic_metre = m³*
23
+ volume_flux_cubic_metre_per_hour = m³/h
24
+ corrected_volume_flux_cubic_metre_per_hour = m³/h*
25
+ volume_flux_cubic_metre_per_day = m³/d
26
+ corrected_volume_flux_cubic_metre_per_day = m³/d
27
+ volume_litre = l
28
+ mass_kilogram = kg
29
+ force_newton = n
30
+ energy_newton_meter = nm
31
+ pressure_pascal = pa
32
+ pressure_bar = bar
33
+ energy_joule = j
34
+ thermal_power_rate_of_change_joule_per_hour = j/h
35
+ active_power_watt = w
36
+ apparent_power_volt_ampere = va
37
+ reactive_power_var = var
38
+ active_energy_value_watt_hour = wh
39
+ apparent_energy_value_volt_ampere_hour = vah
40
+ reactive_energy_value_var_hour = varh
41
+ current_ampere = a
42
+ electrical_charge_coulomb = c
43
+ voltage_volt = v
44
+ electric_field_strength_volt_per_metre = v/m
45
+ capacitance_farad = f
46
+ resistance_ohm = ω
47
+ resistivity = ωm²/m
48
+ magnetic_flux_weber = wb
49
+ magnetic_flux_density_tesla = t
50
+ magnetic_field_strength_ampere_per_metre = a/m
51
+ inductance_henry = h
52
+ frequency_hertz = hz
53
+ rw_active_energy_value = 1/(wh)
54
+ rb_reactive_energy_value = 1/(varh)
55
+ rs_apparent_energy_value = 1/(vah)
56
+ volt_squared_hour_volt_squared_hour_meter = v²h
57
+ ampere_squared_hour = a²h
58
+ mass_flux_kilogram_per_second = kg/s
59
+ conductance_siemens = s, mho
60
+ temperature_kelvin = k
61
+ ru2h_volt_squared_hour_meter = 1/(v²h)
62
+ ri2h_ampere_squared_hour_meter = 1/(a²h)
63
+ rv_meter = 1/m³
64
+ percentage = %%
65
+ ampere_hours = ah
66
+ energy_per_volume = wh/m³
67
+ calorific_value_wobbe = j/m³
68
+ molar_fraction_of_gas_composition_mole_percent = mol %%
69
+ mass_density_quantity_of_material = g/m³
70
+ dynamic_viscosity_pascal_second = pa s
71
+ specific_energy_joule_kilogram = j/kg
72
+ pressure_gram_per_square_centimeter = g/cm²
73
+ pressure_atmosphere = atm
74
+ signal_strength_milliwatt = dbm
75
+ signal_strength_microvolt = dbµv
76
+ logarithmic_unit = db
77
+ length_inch = in
78
+ length_foot = ft
79
+ mass_pound = lb
80
+ temperature_fahrenheit = °f
81
+ temperature_rankine = °r
82
+ area_square_inch = sq. in
83
+ area_square_foot = sq ft
84
+ area_acre = ac
85
+ volume_cubic_inch = cu in
86
+ volume_cubic_foot = cu ft
87
+ volume_acre_foot = ac ft
88
+ volume_gallon_imperial = gal(imp)
89
+ volume_gallon_us = gal(us)
90
+ force_pound_force = lbf
91
+ pressure_pound_force_per_square_inch = psi
92
+ density_pound_per_cubic_foot = lb/cu ft
93
+ dynamic_viscosity = lb/(ft .s)
94
+ kinematic_viscosity_square_foot_per_second = sq ft/s
95
+ energy_british_thermal_unit = btu
96
+ energy_therm_eu = thm(ec)
97
+ energy_therm_us = thm(us)
98
+ calorific_value_of_mass_lenthalpy = btu/lb
99
+ calorific_value_of_volume_wobbe = btu/cu ft
100
+ volume_meter_cubic_feet_rv = cu ft rv
101
+ speed_foot_per_second = ft/s
102
+ volume_flux_cubic_foot_per_second = cu ft/s
103
+ volume_flux_cubic_foot_per_min = cu ft/min
104
+ volume_flux_cubic_foot_per_hour = cu ft/h
105
+ volume_flux_cubic_foot_per_day = cu ft/d
106
+ volume_flux_acre_foot_per_second = ac ft/s
107
+ volume_flux_acre_foot_per_min = ac ft/min
108
+ volume_flux_acre_foot_per_hour = ac ft/h
109
+ volume_flux_acre_foot_per_day = ac ft/d
110
+ volume_imperial_gallon_meter_rv = gal(imp) rv
111
+ volume_flux_imperial_gallon_per_second = gal(imp)/s
112
+ volume_flux_imperial_gallon_per_min = gal(imp)/min
113
+ volume_flux_imperial_gallon_per_hour = gal(imp)/h
114
+ volume_flux_imperial_gallon_per_day = gal(imp)/d
115
+ volume_us_gallon_rv = gal(us) rv
116
+ volume_flux_us_gallon_per_second = gal(us)/s
117
+ volume_flux_us_gallon_per_min = gal(us)/min
118
+ volume_flux_us_gallon_per_hour = gal(us)/h
119
+ volume_flux_us_gallon_per_day = gal(us)/d
120
+ energy_flow_british_thermal_unit_per_second = btu/s
121
+ energy_flow_british_thermal_unit_per_minute = btu/min
122
+ energy_flow_british_thermal_unit_per_hour = btu/h
123
+ energy_flow_british_thermal_unit_per_day = btu/d
124
+ extended_table_of_units = extended
125
+ other_unit = other
126
+ no_unit_unitless_count = count
@@ -1,53 +1,53 @@
1
- import os
2
- import tomllib
3
- from typing_extensions import deprecated
4
-
5
-
6
- print("Path: ", os.getcwd())
7
-
8
-
9
- @deprecated("use settings.settings")
10
- def get_values(*args: str) -> dict | None:
11
- args = list(args)
12
- par = config
13
- while args:
14
- key = args.pop(0)
15
- try:
16
- par = par[key]
17
- continue
18
- except KeyError as e:
19
- print(f"error: {e.args[0]}")
20
- return None
21
- return par
22
-
23
-
24
- if not os.path.isfile(path := ".//config.toml"):
25
- path = F"{os.path.dirname(__file__)}{path}"
26
- elif not os.path.isfile(path):
27
- print("NOT FIND CONFIGURATION: <config.toml>")
28
- with open(path, "rb") as f:
29
- config = tomllib.load(f)
30
- print(F"Find configuration <config.toml> with path: {f}")
31
-
32
- _messages = get_values("DLMS", "messages")
33
-
34
-
35
- def get_message(value: str) -> str:
36
- """translate %... from config.toml"""
37
- value: bytearray = bytearray(value, "utf-8")
38
- ret: bytearray = bytearray()
39
- while value:
40
- if value.startswith(b"$$"):
41
- value.pop(0)
42
- ret.append(value.pop(0))
43
- elif value.startswith(b"$"):
44
- key, sep, value = value[1:].partition(b"$")
45
- if key:
46
- if _messages and (translate := _messages.get(key.decode("utf-8"))):
47
- val = bytes(translate, "utf-8")
48
- else:
49
- val = key
50
- ret.extend(val)
51
- else:
52
- ret.append(value.pop(0))
53
- return ret.decode("utf-8", errors="strict")
1
+ import os
2
+ import tomllib
3
+ from typing_extensions import deprecated
4
+
5
+
6
+ print("Path: ", os.getcwd())
7
+
8
+
9
+ @deprecated("use settings.settings")
10
+ def get_values(*args: str) -> dict | None:
11
+ args = list(args)
12
+ par = config
13
+ while args:
14
+ key = args.pop(0)
15
+ try:
16
+ par = par[key]
17
+ continue
18
+ except KeyError as e:
19
+ print(f"error: {e.args[0]}")
20
+ return None
21
+ return par
22
+
23
+
24
+ if not os.path.isfile(path := ".//config.toml"):
25
+ path = F"{os.path.dirname(__file__)}{path}"
26
+ elif not os.path.isfile(path):
27
+ print("NOT FIND CONFIGURATION: <config.toml>")
28
+ with open(path, "rb") as f:
29
+ config = tomllib.load(f)
30
+ print(F"Find configuration <config.toml> with path: {f}")
31
+
32
+ _messages = get_values("DLMS", "messages")
33
+
34
+
35
+ def get_message(value: str) -> str:
36
+ """translate %... from config.toml"""
37
+ value: bytearray = bytearray(value, "utf-8")
38
+ ret: bytearray = bytearray()
39
+ while value:
40
+ if value.startswith(b"$$"):
41
+ value.pop(0)
42
+ ret.append(value.pop(0))
43
+ elif value.startswith(b"$"):
44
+ key, sep, value = value[1:].partition(b"$")
45
+ if key:
46
+ if _messages and (translate := _messages.get(key.decode("utf-8"))):
47
+ val = bytes(translate, "utf-8")
48
+ else:
49
+ val = key
50
+ ret.extend(val)
51
+ else:
52
+ ret.append(value.pop(0))
53
+ return ret.decode("utf-8", errors="strict")
@@ -0,0 +1,107 @@
1
+ from ...types import ut
2
+ from typing import Final
3
+
4
+
5
+ DATA: Final[ut.CosemClassId] = ut.CosemClassId(1)
6
+ REGISTER: Final[ut.CosemClassId] = ut.CosemClassId(3)
7
+ EXT_REGISTER: Final[ut.CosemClassId] = ut.CosemClassId(4)
8
+ DEMAND_REGISTER: Final[ut.CosemClassId] = ut.CosemClassId(5)
9
+ REGISTER_ACTIVATION: Final[ut.CosemClassId] = ut.CosemClassId(6)
10
+ PROFILE_GENERIC: Final[ut.CosemClassId] = ut.CosemClassId(7)
11
+ CLOCK: Final[ut.CosemClassId] = ut.CosemClassId(8)
12
+ SCRIPT_TABLE: Final[ut.CosemClassId] = ut.CosemClassId(9)
13
+ SCHEDULE: Final[ut.CosemClassId] = ut.CosemClassId(10)
14
+ SPECIAL_DAYS_TABLE: Final[ut.CosemClassId] = ut.CosemClassId(11)
15
+ ASSOCIATION_SN: Final[ut.CosemClassId] = ut.CosemClassId(12)
16
+ ASSOCIATION_LN: Final[ut.CosemClassId] = ut.CosemClassId(15)
17
+ SAP_ASSIGNMENT: Final[ut.CosemClassId] = ut.CosemClassId(17)
18
+ IMAGE_TRANSFER: Final[ut.CosemClassId] = ut.CosemClassId(18)
19
+ IEC_LOCAL_PORT_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(19)
20
+ ACTIVITY_CALENDAR: Final[ut.CosemClassId] = ut.CosemClassId(20)
21
+ REGISTER_MONITOR: Final[ut.CosemClassId] = ut.CosemClassId(21)
22
+ SINGLE_ACTION_SCHEDULE: Final[ut.CosemClassId] = ut.CosemClassId(22)
23
+ IEC_HDLC_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(23)
24
+ IEC_TWISTED_PAIR_1_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(24)
25
+ M_BUS_SLAVE_PORT_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(25)
26
+ UTILITY_TABLES: Final[ut.CosemClassId] = ut.CosemClassId(26)
27
+ MODEM_CONFIGURATION: Final[ut.CosemClassId] = ut.CosemClassId(27)
28
+ PSTN_MODEM_CONFIGURATION: Final[ut.CosemClassId] = ut.CosemClassId(27)
29
+ AUTO_ANSWER: Final[ut.CosemClassId] = ut.CosemClassId(28)
30
+ AUTO_CONNECT: Final[ut.CosemClassId] = ut.CosemClassId(29)
31
+ PSTN_AUTO_DIAL: Final[ut.CosemClassId] = ut.CosemClassId(29)
32
+ COSEM_DATA_PROTECTION: Final[ut.CosemClassId] = ut.CosemClassId(30)
33
+ PUSH_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(40)
34
+ TCP_UDP_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(41)
35
+ IPV4_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(42)
36
+ PRIME_NB_OFDM_PLC_MAC_ADDRESS_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(43)
37
+ PPP_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(44)
38
+ GPRS_MODEM_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(45)
39
+ SMTP_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(46)
40
+ GSM_DIAGNOSTIC: Final[ut.CosemClassId] = ut.CosemClassId(47)
41
+ IPV6_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(48)
42
+ S_FSK_PHY_MAC_SET_UP: Final[ut.CosemClassId] = ut.CosemClassId(50)
43
+ S_FSK_ACTIVE_INITIATOR: Final[ut.CosemClassId] = ut.CosemClassId(51)
44
+ S_FSK_MAC_SYNCHRONIZATION_TIMEOUTS: Final[ut.CosemClassId] = ut.CosemClassId(52)
45
+ S_FSK_MAC_COUNTERS: Final[ut.CosemClassId] = ut.CosemClassId(53)
46
+ IEC_61334_4_32_LLC_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(55)
47
+ S_FSK_REPORTING_SYSTEM_LIST: Final[ut.CosemClassId] = ut.CosemClassId(56)
48
+ ISO_IEC_8802_2_LLC_TYPE_1_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(57)
49
+ ISO_IEC_8802_2_LLC_TYPE_2_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(58)
50
+ ISO_IEC_8802_2_LLC_TYPE_3_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(59)
51
+ REGISTER_TABLE: Final[ut.CosemClassId] = ut.CosemClassId(61)
52
+ COMPACT_DATA: Final[ut.CosemClassId] = ut.CosemClassId(62)
53
+ STATUS_MAPPING: Final[ut.CosemClassId] = ut.CosemClassId(63)
54
+ SECURITY_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(64)
55
+ PARAMETER_MONITOR: Final[ut.CosemClassId] = ut.CosemClassId(65)
56
+ SENSOR_MANAGER_INTERFACE_CLASS: Final[ut.CosemClassId] = ut.CosemClassId(67)
57
+ ARBITRATOR: Final[ut.CosemClassId] = ut.CosemClassId(68)
58
+ DISCONNECT_CONTROL: Final[ut.CosemClassId] = ut.CosemClassId(70)
59
+ LIMITER: Final[ut.CosemClassId] = ut.CosemClassId(71)
60
+ M_BUS_CLIENT: Final[ut.CosemClassId] = ut.CosemClassId(72)
61
+ WIRELESS_MODE_Q_CHANNEL: Final[ut.CosemClassId] = ut.CosemClassId(73)
62
+ M_BUS_MASTER_PORT_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(74)
63
+ DLMS_COSEM_SERVER_M_BUS_PORT_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(76)
64
+ M_BUS_DIAGNOSTIC: Final[ut.CosemClassId] = ut.CosemClassId(77)
65
+ _61334_4_32_LLC_SSCS_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(80)
66
+ PRIME_NB_OFDM_PLC_PHYSICAL_LAYER_COUNTERS: Final[ut.CosemClassId] = ut.CosemClassId(81)
67
+ PRIME_NB_OFDM_PLC_MAC_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(82)
68
+ PRIME_NB_OFDM_PLC_MAC_FUNCTIONAL_PARAMETERS: Final[ut.CosemClassId] = ut.CosemClassId(83)
69
+ PRIME_NB_OFDM_PLC_MAC_COUNTERS: Final[ut.CosemClassId] = ut.CosemClassId(84)
70
+ PRIME_NB_OFDM_PLC_MAC_NETWORK_ADMINISTRATION_DATA: Final[ut.CosemClassId] = ut.CosemClassId(85)
71
+ PRIME_NB_OFDM_PLC_APPLICATION_IDENTIFICATION: Final[ut.CosemClassId] = ut.CosemClassId(86)
72
+ G3_PLC_MAC_LAYER_COUNTERS: Final[ut.CosemClassId] = ut.CosemClassId(90)
73
+ G3_NB_OFDM_PLC_MAC_LAYER_COUNTERS: Final[ut.CosemClassId] = ut.CosemClassId(90)
74
+ G3_PLC_MAC_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(91)
75
+ G3_NB_OFDM_PLC_MAC_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(91)
76
+ G3_PLC_MAC_6LOWPAN_ADAPTATION_LAYER_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(92)
77
+ G3_NB_OFDM_PLC_6LOWPAN_ADAPTATION_LAYER_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(92)
78
+ WI_SUN_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(95)
79
+ WI_SUN_DIAGNOSTIC: Final[ut.CosemClassId] = ut.CosemClassId(96)
80
+ RPL_DIAGNOSTIC: Final[ut.CosemClassId] = ut.CosemClassId(97)
81
+ MPL_DIAGNOSTIC: Final[ut.CosemClassId] = ut.CosemClassId(98)
82
+ NTP_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(100)
83
+ ZIGBEE_SAS_STARTUP: Final[ut.CosemClassId] = ut.CosemClassId(101)
84
+ ZIGBEE_SAS_JOIN: Final[ut.CosemClassId] = ut.CosemClassId(102)
85
+ ZIGBEE_SAS_APS_FRAGMENTATION: Final[ut.CosemClassId] = ut.CosemClassId(103)
86
+ ZIGBEE_NETWORK_CONTROL: Final[ut.CosemClassId] = ut.CosemClassId(104)
87
+ ZIGBEE_TUNNEL_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(105)
88
+ ACCOUNT: Final[ut.CosemClassId] = ut.CosemClassId(111)
89
+ CREDIT_INTERFACE_CLASS: Final[ut.CosemClassId] = ut.CosemClassId(112)
90
+ CHARGE: Final[ut.CosemClassId] = ut.CosemClassId(113)
91
+ TOKEN_GATEWAY: Final[ut.CosemClassId] = ut.CosemClassId(115)
92
+ FUNCTION_CONTROL: Final[ut.CosemClassId] = ut.CosemClassId(122)
93
+ ARRAY_MANAGER: Final[ut.CosemClassId] = ut.CosemClassId(123)
94
+ COMMUNICATION_PORT_PROTECTION: Final[ut.CosemClassId] = ut.CosemClassId(124)
95
+ SCHC_LPWAN_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(126)
96
+ SCHC_LPWAN_DIAGNOSTIC: Final[ut.CosemClassId] = ut.CosemClassId(127)
97
+ LoRaWAN_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(128)
98
+ LoRaWAN_DIAGNOSTIC: Final[ut.CosemClassId] = ut.CosemClassId(129)
99
+ ISO_IEC14908_IDENTIFICATION: Final[ut.CosemClassId] = ut.CosemClassId(130)
100
+ ISO_IEC14908_PROTOCOL_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(131)
101
+ ISO_IEC14908_PROTOCOL_STATUS: Final[ut.CosemClassId] = ut.CosemClassId(132)
102
+ ISO_IEC14908_PROTOCOL_DIAGNOSTIC: Final[ut.CosemClassId] = ut.CosemClassId(133)
103
+ HS_PLC_ISO_IEC_12139_1_MAC_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(140)
104
+ HS_PLC_ISO_IEC_12139_1_CPAS_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(141)
105
+ HS_PLC_ISO_IEC_12139_1_IP_SSAS_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(142)
106
+ HS_PLC_ISO_IEC_12139_1_HDLC_SSAS_SETUP: Final[ut.CosemClassId] = ut.CosemClassId(143)
107
+ LTE_MONITORING: Final[ut.CosemClassId] = ut.CosemClassId(151)
@@ -1,3 +1,3 @@
1
- from ..cosem_interface_classes import cosem_interface_class as ic, attr_indexes as ai
2
- from ..cosem_interface_classes.overview import ClassID
3
- from ..types import common_data_types as cdt, cosem_service_types as cst, useful_types as ut
1
+ from ..cosem_interface_classes import cosem_interface_class as ic
2
+ from ..cosem_interface_classes.overview import ClassID
3
+ from ..types import common_data_types as cdt, cosem_service_types as cst, useful_types as ut
@@ -1,2 +1,3 @@
1
- from . import collection, implementations as ic_impl, cosem_interface_class as ic
2
- from .parameter import Parameter
1
+ from . import collection, implementations as ic_impl, cosem_interface_class as ic
2
+ from .parameter import Parameter
3
+ from .Overview import class_id