zigbee-herdsman 0.36.2 → 0.38.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (35) hide show
  1. package/.release-please-manifest.json +1 -1
  2. package/CHANGELOG.md +29 -0
  3. package/dist/adapter/ember/adapter/emberAdapter.d.ts +1 -1
  4. package/dist/adapter/ember/adapter/emberAdapter.d.ts.map +1 -1
  5. package/dist/adapter/ember/adapter/emberAdapter.js +37 -36
  6. package/dist/adapter/ember/adapter/emberAdapter.js.map +1 -1
  7. package/dist/adapter/ember/ezsp/ezsp.d.ts.map +1 -1
  8. package/dist/adapter/ember/ezsp/ezsp.js +3 -1
  9. package/dist/adapter/ember/ezsp/ezsp.js.map +1 -1
  10. package/dist/adapter/events.d.ts +12 -9
  11. package/dist/adapter/events.d.ts.map +1 -1
  12. package/dist/controller/controller.d.ts.map +1 -1
  13. package/dist/controller/controller.js +7 -5
  14. package/dist/controller/controller.js.map +1 -1
  15. package/dist/controller/events.d.ts +1 -1
  16. package/dist/controller/events.d.ts.map +1 -1
  17. package/dist/controller/events.js +2 -0
  18. package/dist/controller/events.js.map +1 -1
  19. package/dist/controller/helpers/zclFrameConverter.js +1 -1
  20. package/dist/controller/helpers/zclFrameConverter.js.map +1 -1
  21. package/dist/controller/model/group.d.ts.map +1 -1
  22. package/dist/controller/model/group.js +3 -0
  23. package/dist/controller/model/group.js.map +1 -1
  24. package/dist/zcl/definition/cluster.d.ts.map +1 -1
  25. package/dist/zcl/definition/cluster.js +241 -231
  26. package/dist/zcl/definition/cluster.js.map +1 -1
  27. package/dist/zcl/definition/manufacturerCode.d.ts +724 -1077
  28. package/dist/zcl/definition/manufacturerCode.d.ts.map +1 -1
  29. package/dist/zcl/definition/manufacturerCode.js +727 -1080
  30. package/dist/zcl/definition/manufacturerCode.js.map +1 -1
  31. package/dist/zcl/definition/status.d.ts +46 -15
  32. package/dist/zcl/definition/status.d.ts.map +1 -1
  33. package/dist/zcl/definition/status.js +36 -4
  34. package/dist/zcl/definition/status.js.map +1 -1
  35. package/package.json +2 -2
@@ -29,7 +29,7 @@ const Cluster = {
29
29
  develcoPrimarySwVersion: { ID: 0x8000, type: dataType_1.default.octetStr, manufacturerCode: manufacturerCode_1.default.DEVELCO },
30
30
  develcoPrimaryHwVersion: { ID: 0x8020, type: dataType_1.default.octetStr, manufacturerCode: manufacturerCode_1.default.DEVELCO },
31
31
  develcoLedControl: { ID: 0x8100, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.DEVELCO },
32
- schneiderMeterRadioPower: { ID: 0xE200, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
32
+ schneiderMeterRadioPower: { ID: 0xE200, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
33
33
  },
34
34
  commands: {
35
35
  resetFactDefault: {
@@ -429,9 +429,9 @@ const Cluster = {
429
429
  tuyaBacklightMode: { ID: 0x8001, type: dataType_1.default.enum8 },
430
430
  moesStartUpOnOff: { ID: 0x8002, type: dataType_1.default.enum8 },
431
431
  tuyaOperationMode: { ID: 0x8004, type: dataType_1.default.enum8 },
432
- elkoPreWarningTime: { ID: 0xE000, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ELKO },
433
- elkoOnTimeReload: { ID: 0xE001, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.ELKO },
434
- elkoOnTimeReloadOptions: { ID: 0xE002, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.ELKO },
432
+ elkoPreWarningTime: { ID: 0xE000, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ADEO },
433
+ elkoOnTimeReload: { ID: 0xE001, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.ADEO },
434
+ elkoOnTimeReloadOptions: { ID: 0xE002, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.ADEO },
435
435
  nodonTransitionTime: { ID: 0x0001, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.NODON },
436
436
  },
437
437
  commands: {
@@ -466,6 +466,12 @@ const Cluster = {
466
466
  { name: 'offwaittime', type: dataType_1.default.uint16 },
467
467
  ],
468
468
  },
469
+ tuyaAction: {
470
+ ID: 0xFD,
471
+ parameters: [
472
+ { name: 'value', type: dataType_1.default.uint8 },
473
+ ],
474
+ },
469
475
  },
470
476
  commandsResponse: {},
471
477
  },
@@ -493,21 +499,21 @@ const Cluster = {
493
499
  offTransitionTime: { ID: 19, type: dataType_1.default.uint16 },
494
500
  defaultMoveRate: { ID: 20, type: dataType_1.default.uint16 },
495
501
  startUpCurrentLevel: { ID: 16384, type: dataType_1.default.uint8 },
496
- elkoStartUpCurrentLevel: { ID: 0x4000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.ELKO },
497
- ubisysMinimumOnLevel: { ID: 0x0000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
498
- ubisysValveType: { ID: 0x0001, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.Ubisys },
499
- ubisysCyclePeriod: { ID: 0x0002, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
500
- ubisysSeason: { ID: 0x0003, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.Ubisys },
501
- ubisysBackupLevel: { ID: 0x0004, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
502
- ubisysAlternateBackupLevel: { ID: 0x0005, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
503
- ubisysLowerRange: { ID: 0x0006, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
504
- ubisysUpperRange: { ID: 0x0007, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
505
- ubisysPumpThresholdOn: { ID: 0x0008, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
506
- ubisysPumpThresholdOff: { ID: 0x0009, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
507
- ubisysHeatingDemandEnableThreshold: { ID: 0x000A, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
508
- ubisysHeatingDemandDisableThreshold: { ID: 0x000B, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
509
- ubisysCoolingDemandEnableThreshold: { ID: 0x000C, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
510
- ubisysCoolingDemandDisableThreshold: { ID: 0x000D, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
502
+ elkoStartUpCurrentLevel: { ID: 0x4000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.ADEO },
503
+ ubisysMinimumOnLevel: { ID: 0x0000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
504
+ ubisysValveType: { ID: 0x0001, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
505
+ ubisysCyclePeriod: { ID: 0x0002, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
506
+ ubisysSeason: { ID: 0x0003, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
507
+ ubisysBackupLevel: { ID: 0x0004, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
508
+ ubisysAlternateBackupLevel: { ID: 0x0005, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
509
+ ubisysLowerRange: { ID: 0x0006, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
510
+ ubisysUpperRange: { ID: 0x0007, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
511
+ ubisysPumpThresholdOn: { ID: 0x0008, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
512
+ ubisysPumpThresholdOff: { ID: 0x0009, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
513
+ ubisysHeatingDemandEnableThreshold: { ID: 0x000A, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
514
+ ubisysHeatingDemandDisableThreshold: { ID: 0x000B, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
515
+ ubisysCoolingDemandEnableThreshold: { ID: 0x000C, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
516
+ ubisysCoolingDemandDisableThreshold: { ID: 0x000D, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
511
517
  },
512
518
  commands: {
513
519
  moveToLevel: {
@@ -1746,30 +1752,30 @@ const Cluster = {
1746
1752
  windowCoveringMode: { ID: 23, type: dataType_1.default.bitmap8 },
1747
1753
  intermediateSetpointsLift: { ID: 24, type: dataType_1.default.octetStr },
1748
1754
  intermediateSetpointsTilt: { ID: 25, type: dataType_1.default.octetStr },
1749
- ubisysTurnaroundGuardTime: { ID: 0x1000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
1750
- ubisysLiftToTiltTransitionSteps: { ID: 0x1001, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1751
- ubisysTotalSteps: { ID: 0x1002, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1752
- ubisysLiftToTiltTransitionSteps2: { ID: 0x1003, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1753
- ubisysTotalSteps2: { ID: 0x1004, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1754
- ubisysAdditionalSteps: { ID: 0x1005, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
1755
- ubisysInactivePowerThreshold: { ID: 0x1006, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1756
- ubisysStartupSteps: { ID: 0x1007, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1755
+ ubisysTurnaroundGuardTime: { ID: 0x1000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1756
+ ubisysLiftToTiltTransitionSteps: { ID: 0x1001, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1757
+ ubisysTotalSteps: { ID: 0x1002, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1758
+ ubisysLiftToTiltTransitionSteps2: { ID: 0x1003, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1759
+ ubisysTotalSteps2: { ID: 0x1004, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1760
+ ubisysAdditionalSteps: { ID: 0x1005, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1761
+ ubisysInactivePowerThreshold: { ID: 0x1006, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1762
+ ubisysStartupSteps: { ID: 0x1007, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1757
1763
  tuyaMovingState: { ID: 0xf000, type: dataType_1.default.enum8 },
1758
1764
  tuyaCalibration: { ID: 0xf001, type: dataType_1.default.enum8 },
1759
- stepPositionLift: { ID: 0xf001, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LegrandNetatmo },
1765
+ stepPositionLift: { ID: 0xf001, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LEGRAND_GROUP },
1760
1766
  tuyaMotorReversal: { ID: 0xf002, type: dataType_1.default.enum8 },
1761
- calibrationMode: { ID: 0xf002, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LegrandNetatmo },
1767
+ calibrationMode: { ID: 0xf002, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LEGRAND_GROUP },
1762
1768
  moesCalibrationTime: { ID: 0xf003, type: dataType_1.default.uint16 },
1763
- targetPositionTiltPercentage: { ID: 0xf003, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LegrandNetatmo },
1764
- stepPositionTilt: { ID: 0xf004, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LegrandNetatmo },
1765
- elkoDriveCloseDuration: { ID: 0xE000, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ELKO },
1766
- elkoProtectionStatus: { ID: 0xE010, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.ELKO },
1767
- elkoProtectionSensor: { ID: 0xE013, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.ELKO },
1768
- elkoSunProtectionIlluminanceThreshold: { ID: 0xE012, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ELKO },
1769
- elkoLiftDriveUpTime: { ID: 0xE014, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ELKO },
1770
- elkoLiftDriveDownTime: { ID: 0xE015, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ELKO },
1771
- elkoTiltOpenCloseAndStepTime: { ID: 0xE016, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ELKO },
1772
- elkoTiltPositionPercentageAfterMoveToLevel: { ID: 0xE017, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.ELKO },
1769
+ targetPositionTiltPercentage: { ID: 0xf003, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LEGRAND_GROUP },
1770
+ stepPositionTilt: { ID: 0xf004, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LEGRAND_GROUP },
1771
+ elkoDriveCloseDuration: { ID: 0xE000, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ADEO },
1772
+ elkoProtectionStatus: { ID: 0xE010, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.ADEO },
1773
+ elkoProtectionSensor: { ID: 0xE013, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.ADEO },
1774
+ elkoSunProtectionIlluminanceThreshold: { ID: 0xE012, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ADEO },
1775
+ elkoLiftDriveUpTime: { ID: 0xE014, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ADEO },
1776
+ elkoLiftDriveDownTime: { ID: 0xE015, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ADEO },
1777
+ elkoTiltOpenCloseAndStepTime: { ID: 0xE016, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ADEO },
1778
+ elkoTiltPositionPercentageAfterMoveToLevel: { ID: 0xE017, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.ADEO },
1773
1779
  },
1774
1780
  commands: {
1775
1781
  upOpen: {
@@ -1923,43 +1929,43 @@ const Cluster = {
1923
1929
  acLouverPosition: { ID: 69, type: dataType_1.default.enum8 },
1924
1930
  acCollTemp: { ID: 70, type: dataType_1.default.int16 },
1925
1931
  acCapacityFormat: { ID: 71, type: dataType_1.default.enum8 },
1926
- SinopeOccupancy: { ID: 1024, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.Sinope },
1927
- SinopeMainCycleOutput: { ID: 1025, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Sinope },
1928
- SinopeBacklight: { ID: 1026, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.Sinope },
1929
- SinopeAuxCycleOutput: { ID: 1028, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Sinope },
1932
+ SinopeOccupancy: { ID: 1024, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.SINOPE_TECHNOLOGIES },
1933
+ SinopeMainCycleOutput: { ID: 1025, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SINOPE_TECHNOLOGIES },
1934
+ SinopeBacklight: { ID: 1026, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.SINOPE_TECHNOLOGIES },
1935
+ SinopeAuxCycleOutput: { ID: 1028, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SINOPE_TECHNOLOGIES },
1930
1936
  StelproSystemMode: { ID: 0x401c, type: dataType_1.default.enum8 },
1931
1937
  StelproOutdoorTemp: { ID: 0x4001, type: dataType_1.default.int16 },
1932
- viessmannWindowOpenInternal: { ID: 0x4000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.VIESSMAN_ELEKTRO },
1933
- viessmannWindowOpenForce: { ID: 0x4003, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.VIESSMAN_ELEKTRO },
1934
- viessmannAssemblyMode: { ID: 0x4012, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.VIESSMAN_ELEKTRO },
1935
- schneiderWiserSpecific: { ID: 0xe110, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
1936
- danfossWindowOpenInternal: { ID: 0x4000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1937
- danfossWindowOpenExternal: { ID: 0x4003, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1938
- danfossDayOfWeek: { ID: 0x4010, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1939
- danfossTriggerTime: { ID: 0x4011, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1940
- danfossMountedModeActive: { ID: 0x4012, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1941
- danfossMountedModeControl: { ID: 0x4013, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1942
- danfossThermostatOrientation: { ID: 0x4014, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1943
- danfossExternalMeasuredRoomSensor: { ID: 0x4015, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1944
- danfossRadiatorCovered: { ID: 0x4016, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1945
- danfossAlgorithmScaleFactor: { ID: 0x4020, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1946
- danfossHeatAvailable: { ID: 0x4030, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1947
- danfossHeatRequired: { ID: 0x4031, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1948
- danfossLoadBalancingEnable: { ID: 0x4032, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1949
- danfossLoadRoomMean: { ID: 0x4040, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1950
- danfossLoadEstimate: { ID: 0x404a, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1951
- danfossRegulationSetpointOffset: { ID: 0x404b, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1952
- danfossAdaptionRunControl: { ID: 0x404c, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1953
- danfossAdaptionRunStatus: { ID: 0x404d, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1954
- danfossAdaptionRunSettings: { ID: 0x404e, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1955
- danfossPreheatStatus: { ID: 0x404f, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1956
- danfossPreheatTime: { ID: 0x4050, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1957
- danfossWindowOpenFeatureEnable: { ID: 0x4051, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1958
- danfossRoomStatusCode: { ID: 0x4100, type: dataType_1.default.bitmap16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1959
- danfossOutputStatus: { ID: 0x4110, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1960
- danfossRoomFloorSensorMode: { ID: 0x4120, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1961
- danfossFloorMinSetpoint: { ID: 0x4121, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1962
- danfossFloorMaxSetpoint: { ID: 0x4122, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1938
+ viessmannWindowOpenInternal: { ID: 0x4000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.VIESSMANN_ELEKTRONIK_GMBH },
1939
+ viessmannWindowOpenForce: { ID: 0x4003, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.VIESSMANN_ELEKTRONIK_GMBH },
1940
+ viessmannAssemblyMode: { ID: 0x4012, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.VIESSMANN_ELEKTRONIK_GMBH },
1941
+ schneiderWiserSpecific: { ID: 0xe110, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
1942
+ danfossWindowOpenInternal: { ID: 0x4000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1943
+ danfossWindowOpenExternal: { ID: 0x4003, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1944
+ danfossDayOfWeek: { ID: 0x4010, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1945
+ danfossTriggerTime: { ID: 0x4011, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1946
+ danfossMountedModeActive: { ID: 0x4012, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1947
+ danfossMountedModeControl: { ID: 0x4013, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1948
+ danfossThermostatOrientation: { ID: 0x4014, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1949
+ danfossExternalMeasuredRoomSensor: { ID: 0x4015, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1950
+ danfossRadiatorCovered: { ID: 0x4016, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1951
+ danfossAlgorithmScaleFactor: { ID: 0x4020, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1952
+ danfossHeatAvailable: { ID: 0x4030, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1953
+ danfossHeatRequired: { ID: 0x4031, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1954
+ danfossLoadBalancingEnable: { ID: 0x4032, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1955
+ danfossLoadRoomMean: { ID: 0x4040, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1956
+ danfossLoadEstimate: { ID: 0x404a, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1957
+ danfossRegulationSetpointOffset: { ID: 0x404b, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1958
+ danfossAdaptionRunControl: { ID: 0x404c, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1959
+ danfossAdaptionRunStatus: { ID: 0x404d, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1960
+ danfossAdaptionRunSettings: { ID: 0x404e, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1961
+ danfossPreheatStatus: { ID: 0x404f, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1962
+ danfossPreheatTime: { ID: 0x4050, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1963
+ danfossWindowOpenFeatureEnable: { ID: 0x4051, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1964
+ danfossRoomStatusCode: { ID: 0x4100, type: dataType_1.default.bitmap16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1965
+ danfossOutputStatus: { ID: 0x4110, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1966
+ danfossRoomFloorSensorMode: { ID: 0x4120, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1967
+ danfossFloorMinSetpoint: { ID: 0x4121, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1968
+ danfossFloorMaxSetpoint: { ID: 0x4122, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1963
1969
  elkoLoad: { ID: 0x0401, type: dataType_1.default.uint16 },
1964
1970
  elkoDisplayText: { ID: 0x0402, type: dataType_1.default.charStr },
1965
1971
  elkoSensor: { ID: 0x0403, type: dataType_1.default.enum8 },
@@ -1978,24 +1984,24 @@ const Cluster = {
1978
1984
  elkoCalibration: { ID: 0x0417, type: dataType_1.default.int8 },
1979
1985
  elkoLastMessageId: { ID: 0x0418, type: dataType_1.default.uint8 },
1980
1986
  elkoLastMessageStatus: { ID: 0x0419, type: dataType_1.default.uint8 },
1981
- fourNoksHysteresisHigh: { ID: 0x0101, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default._4_NOKS },
1982
- fourNoksHysteresisLow: { ID: 0x0102, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default._4_NOKS },
1983
- ubisysClassBTemperatureOffset: { ID: 0x0000, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.Ubisys },
1984
- ubisysReturnFlowTemperatureWeight: { ID: 0x0001, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.Ubisys },
1985
- ubisysRawOutdoorTemperature: { ID: 0x0002, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.Ubisys },
1986
- ubisysRawLocalTemperatureA: { ID: 0x0003, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.Ubisys },
1987
- ubisysRawLocalTemperatureB: { ID: 0x0004, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.Ubisys },
1988
- ubisysRawForwardFlowTemperature: { ID: 0x0005, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.Ubisys },
1989
- ubisysRawReturnFlowTemperature: { ID: 0x0006, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.Ubisys },
1990
- ubisysInstalledExtensions: { ID: 0x0007, type: dataType_1.default.bitmap64, manufacturerCode: manufacturerCode_1.default.Ubisys },
1991
- ubisysTemperatureOffset: { ID: 0x0010, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.Ubisys },
1992
- ubisysDefaultOccupiedHeatingSetpoint: { ID: 0x0011, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1993
- ubisysVacationMode: { ID: 0x0012, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.Ubisys },
1994
- ubisysRemoteTemperature: { ID: 0x0013, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1995
- ubisysRemoteTemperatureValidDuration: { ID: 0x0014, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
1996
- ubisysProportionalGain: { ID: 0x0020, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1997
- ubisysProportionalShift: { ID: 0x0021, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.Ubisys },
1998
- ubisysIntegralFactor: { ID: 0x0022, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1987
+ fourNoksHysteresisHigh: { ID: 0x0101, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ASTREL_GROUP_SRL },
1988
+ fourNoksHysteresisLow: { ID: 0x0102, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ASTREL_GROUP_SRL },
1989
+ ubisysClassBTemperatureOffset: { ID: 0x0000, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1990
+ ubisysReturnFlowTemperatureWeight: { ID: 0x0001, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1991
+ ubisysRawOutdoorTemperature: { ID: 0x0002, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1992
+ ubisysRawLocalTemperatureA: { ID: 0x0003, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1993
+ ubisysRawLocalTemperatureB: { ID: 0x0004, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1994
+ ubisysRawForwardFlowTemperature: { ID: 0x0005, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1995
+ ubisysRawReturnFlowTemperature: { ID: 0x0006, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1996
+ ubisysInstalledExtensions: { ID: 0x0007, type: dataType_1.default.bitmap64, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1997
+ ubisysTemperatureOffset: { ID: 0x0010, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1998
+ ubisysDefaultOccupiedHeatingSetpoint: { ID: 0x0011, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1999
+ ubisysVacationMode: { ID: 0x0012, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
2000
+ ubisysRemoteTemperature: { ID: 0x0013, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
2001
+ ubisysRemoteTemperatureValidDuration: { ID: 0x0014, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
2002
+ ubisysProportionalGain: { ID: 0x0020, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
2003
+ ubisysProportionalShift: { ID: 0x0021, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
2004
+ ubisysIntegralFactor: { ID: 0x0022, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1999
2005
  },
2000
2006
  commands: {
2001
2007
  setpointRaiseLower: {
@@ -2128,7 +2134,7 @@ const Cluster = {
2128
2134
  tempDisplayMode: { ID: 0, type: dataType_1.default.enum8 },
2129
2135
  keypadLockout: { ID: 1, type: dataType_1.default.enum8 },
2130
2136
  programmingVisibility: { ID: 2, type: dataType_1.default.enum8 },
2131
- danfossViewingDirection: { ID: 0x4000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
2137
+ danfossViewingDirection: { ID: 0x4000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
2132
2138
  },
2133
2139
  commands: {},
2134
2140
  commandsResponse: {},
@@ -2412,8 +2418,8 @@ const Cluster = {
2412
2418
  lampBurnHours: { ID: 51, type: dataType_1.default.uint24 },
2413
2419
  lampAlarmMode: { ID: 52, type: dataType_1.default.bitmap8 },
2414
2420
  lampBurnHoursTripPoint: { ID: 53, type: dataType_1.default.uint24 },
2415
- elkoControlMode: { ID: 0xE000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.ELKO },
2416
- wiserControlMode: { ID: 0xE000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
2421
+ elkoControlMode: { ID: 0xE000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.ADEO },
2422
+ wiserControlMode: { ID: 0xE000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
2417
2423
  },
2418
2424
  commands: {},
2419
2425
  commandsResponse: {},
@@ -2449,7 +2455,7 @@ const Cluster = {
2449
2455
  tolerance: { ID: 3, type: dataType_1.default.uint16 },
2450
2456
  minPercentChange: { ID: 16, type: dataType_1.default.unknown },
2451
2457
  minAbsoluteChange: { ID: 17, type: dataType_1.default.unknown },
2452
- sprutTemperatureOffset: { ID: 0x6600, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.SprutDevice },
2458
+ sprutTemperatureOffset: { ID: 0x6600, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.SPRUT_DEVICE },
2453
2459
  },
2454
2460
  commands: {},
2455
2461
  commandsResponse: {},
@@ -2488,7 +2494,7 @@ const Cluster = {
2488
2494
  minMeasuredValue: { ID: 1, type: dataType_1.default.uint16 },
2489
2495
  maxMeasuredValue: { ID: 2, type: dataType_1.default.uint16 },
2490
2496
  tolerance: { ID: 3, type: dataType_1.default.uint16 },
2491
- sprutHeater: { ID: 0x6600, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.SprutDevice },
2497
+ sprutHeater: { ID: 0x6600, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.SPRUT_DEVICE },
2492
2498
  },
2493
2499
  commands: {},
2494
2500
  commandsResponse: {},
@@ -2504,12 +2510,12 @@ const Cluster = {
2504
2510
  ultrasonicOToUDelay: { ID: 32, type: dataType_1.default.uint16 },
2505
2511
  ultrasonicUToODelay: { ID: 33, type: dataType_1.default.uint16 },
2506
2512
  ultrasonicUToOThreshold: { ID: 34, type: dataType_1.default.uint8 },
2507
- elkoOccupancyDfltOperationMode: { ID: 0xE000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.ELKO },
2508
- elkoOccupancyOperationMode: { ID: 0xE001, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.ELKO },
2509
- elkoForceOffTimeout: { ID: 0xE002, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ELKO },
2510
- elkoOccupancySensitivity: { ID: 0xE003, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.ELKO },
2511
- sprutOccupancyLevel: { ID: 0x6600, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SprutDevice },
2512
- sprutOccupancySensitivity: { ID: 0x6601, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SprutDevice },
2513
+ elkoOccupancyDfltOperationMode: { ID: 0xE000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.ADEO },
2514
+ elkoOccupancyOperationMode: { ID: 0xE001, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.ADEO },
2515
+ elkoForceOffTimeout: { ID: 0xE002, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ADEO },
2516
+ elkoOccupancySensitivity: { ID: 0xE003, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.ADEO },
2517
+ sprutOccupancyLevel: { ID: 0x6600, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SPRUT_DEVICE },
2518
+ sprutOccupancySensitivity: { ID: 0x6601, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SPRUT_DEVICE },
2513
2519
  },
2514
2520
  commands: {},
2515
2521
  commandsResponse: {},
@@ -2542,8 +2548,8 @@ const Cluster = {
2542
2548
  measuredValue: { ID: 0, type: dataType_1.default.singlePrec },
2543
2549
  minMeasuredValue: { ID: 1, type: dataType_1.default.singlePrec },
2544
2550
  maxMeasuredValue: { ID: 2, type: dataType_1.default.singlePrec },
2545
- sprutCO2Calibration: { ID: 0x6600, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.SprutDevice },
2546
- sprutCO2AutoCalibration: { ID: 0x6601, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.SprutDevice },
2551
+ sprutCO2Calibration: { ID: 0x6600, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.SPRUT_DEVICE },
2552
+ sprutCO2AutoCalibration: { ID: 0x6601, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.SPRUT_DEVICE },
2547
2553
  },
2548
2554
  commands: {},
2549
2555
  commandsResponse: {},
@@ -3314,73 +3320,73 @@ const Cluster = {
3314
3320
  develcoPulseConfiguration: { ID: 0x0300, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.DEVELCO },
3315
3321
  develcoCurrentSummation: { ID: 0x0301, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.DEVELCO },
3316
3322
  develcoInterfaceMode: { ID: 0x0302, type: dataType_1.default.enum16, manufacturerCode: manufacturerCode_1.default.DEVELCO },
3317
- owonL1PhasePower: { ID: 0x2000, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON },
3318
- owonL2PhasePower: { ID: 0x2001, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON },
3319
- owonL3PhasePower: { ID: 0x2002, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON },
3320
- owonL1PhaseReactivePower: { ID: 0x2100, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON },
3321
- owonL2PhaseReactivePower: { ID: 0x2101, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON },
3322
- owonL3PhaseReactivePower: { ID: 0x2102, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON },
3323
- owonReactivePowerSum: { ID: 0x2103, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON },
3324
- owonL1PhaseVoltage: { ID: 0x3000, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3325
- owonL2PhaseVoltage: { ID: 0x3001, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3326
- owonL3PhaseVoltage: { ID: 0x3002, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3327
- owonL1PhaseCurrent: { ID: 0x3100, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3328
- owonL2PhaseCurrent: { ID: 0x3101, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3329
- owonL3PhaseCurrent: { ID: 0x3102, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3330
- owonCurrentSum: { ID: 0x3103, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3331
- owonLeakageCurrent: { ID: 0x3104, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3332
- owonL1Energy: { ID: 0x4000, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON },
3333
- owonL2Energy: { ID: 0x4001, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON },
3334
- owonL3Energy: { ID: 0x4002, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON },
3335
- owonL1ReactiveEnergy: { ID: 0x4100, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON },
3336
- owonL2ReactiveEnergy: { ID: 0x4101, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON },
3337
- owonL3ReactiveEnergy: { ID: 0x4102, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON },
3338
- owonReactiveEnergySum: { ID: 0x4103, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON },
3339
- owonL1PowerFactor: { ID: 0x4104, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.OWON },
3340
- owonL2PowerFactor: { ID: 0x4105, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.OWON },
3341
- owonL3PowerFactor: { ID: 0x4106, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.OWON },
3342
- owonFrequency: { ID: 0x5005, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON },
3343
- owonReportMap: { ID: 0x1000, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.OWON },
3344
- owonLastHistoricalRecordTime: { ID: 0x5000, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON },
3345
- owonOldestHistoricalRecordTime: { ID: 0x5001, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON },
3346
- owonMinimumReportCycle: { ID: 0x5002, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON },
3347
- owonMaximumReportCycle: { ID: 0x5003, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON },
3348
- owonSentHistoricalRecordState: { ID: 0x5004, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON },
3349
- owonAccumulativeEnergyThreshold: { ID: 0x5006, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON },
3350
- owonReportMode: { ID: 0x5007, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON },
3351
- owonPercentChangeInPower: { ID: 0x5007, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON },
3352
- schneiderActiveEnergyTotal: { ID: 0x4010, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3353
- schneiderReactiveEnergyTotal: { ID: 0x4011, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3354
- schneiderApparentEnergyTotal: { ID: 0x4012, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3355
- schneiderPartialActiveEnergyTotal: { ID: 0x4014, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3356
- schneiderPartialReactiveEnergyTotal: { ID: 0x4015, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3357
- schneiderPartialApparentEnergyTotal: { ID: 0x4016, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3358
- schneiderPartialActiveEnergyL1Phase: { ID: 0x4100, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3359
- schneiderPartialReactiveEnergyL1Phase: { ID: 0x4101, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3360
- schneiderPartialApparentEnergyL1Phase: { ID: 0x4102, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3361
- schneiderActiveEnergyL1Phase: { ID: 0x4103, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3362
- schneiderReactiveEnergyL1Phase: { ID: 0x4104, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3363
- schneiderApparentEnergyL1Phase: { ID: 0x4105, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3364
- schneiderPartialActiveEnergyL2Phase: { ID: 0x4200, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3365
- schneiderPartialReactiveEnergyL2Phase: { ID: 0x4201, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3366
- schneiderPartialApparentEnergyL2Phase: { ID: 0x4202, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3367
- schneiderActiveEnergyL2Phase: { ID: 0x4203, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3368
- schneiderReactiveEnergyL2Phase: { ID: 0x4204, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3369
- schneiderApparentEnergyL2Phase: { ID: 0x4205, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3370
- schneiderPartialActiveEnergyL3Phase: { ID: 0x4300, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3371
- schneiderPartialReactiveEnergyL3Phase: { ID: 0x4301, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3372
- schneiderPartialApparentEnergyL3Phase: { ID: 0x4302, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3373
- schneiderActiveEnergyL3Phase: { ID: 0x4303, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3374
- schneiderReactiveEnergyL3Phase: { ID: 0x4304, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3375
- schneiderApparentEnergyL3Phase: { ID: 0x4305, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3376
- schneiderActiveEnergyMultiplier: { ID: 0x4400, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3377
- schneiderActiveEnergyDivisor: { ID: 0x4401, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3378
- schneiderReactiveEnergyMultiplier: { ID: 0x4402, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3379
- schneiderReactiveEnergyDivisor: { ID: 0x4403, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3380
- schneiderApparentEnergyMultiplier: { ID: 0x4404, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3381
- schneiderApparentEnergyDivisor: { ID: 0x4405, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3382
- schneiderEnergyResetDateTime: { ID: 0x4501, type: dataType_1.default.utc, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3383
- schneiderEnergyCountersReportingPeriod: { ID: 0x4600, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3323
+ owonL1PhasePower: { ID: 0x2000, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3324
+ owonL2PhasePower: { ID: 0x2001, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3325
+ owonL3PhasePower: { ID: 0x2002, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3326
+ owonL1PhaseReactivePower: { ID: 0x2100, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3327
+ owonL2PhaseReactivePower: { ID: 0x2101, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3328
+ owonL3PhaseReactivePower: { ID: 0x2102, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3329
+ owonReactivePowerSum: { ID: 0x2103, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3330
+ owonL1PhaseVoltage: { ID: 0x3000, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3331
+ owonL2PhaseVoltage: { ID: 0x3001, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3332
+ owonL3PhaseVoltage: { ID: 0x3002, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3333
+ owonL1PhaseCurrent: { ID: 0x3100, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3334
+ owonL2PhaseCurrent: { ID: 0x3101, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3335
+ owonL3PhaseCurrent: { ID: 0x3102, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3336
+ owonCurrentSum: { ID: 0x3103, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3337
+ owonLeakageCurrent: { ID: 0x3104, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3338
+ owonL1Energy: { ID: 0x4000, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3339
+ owonL2Energy: { ID: 0x4001, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3340
+ owonL3Energy: { ID: 0x4002, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3341
+ owonL1ReactiveEnergy: { ID: 0x4100, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3342
+ owonL2ReactiveEnergy: { ID: 0x4101, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3343
+ owonL3ReactiveEnergy: { ID: 0x4102, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3344
+ owonReactiveEnergySum: { ID: 0x4103, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3345
+ owonL1PowerFactor: { ID: 0x4104, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3346
+ owonL2PowerFactor: { ID: 0x4105, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3347
+ owonL3PowerFactor: { ID: 0x4106, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3348
+ owonFrequency: { ID: 0x5005, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3349
+ owonReportMap: { ID: 0x1000, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3350
+ owonLastHistoricalRecordTime: { ID: 0x5000, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3351
+ owonOldestHistoricalRecordTime: { ID: 0x5001, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3352
+ owonMinimumReportCycle: { ID: 0x5002, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3353
+ owonMaximumReportCycle: { ID: 0x5003, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3354
+ owonSentHistoricalRecordState: { ID: 0x5004, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3355
+ owonAccumulativeEnergyThreshold: { ID: 0x5006, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3356
+ owonReportMode: { ID: 0x5007, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3357
+ owonPercentChangeInPower: { ID: 0x5007, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3358
+ schneiderActiveEnergyTotal: { ID: 0x4010, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3359
+ schneiderReactiveEnergyTotal: { ID: 0x4011, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3360
+ schneiderApparentEnergyTotal: { ID: 0x4012, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3361
+ schneiderPartialActiveEnergyTotal: { ID: 0x4014, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3362
+ schneiderPartialReactiveEnergyTotal: { ID: 0x4015, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3363
+ schneiderPartialApparentEnergyTotal: { ID: 0x4016, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3364
+ schneiderPartialActiveEnergyL1Phase: { ID: 0x4100, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3365
+ schneiderPartialReactiveEnergyL1Phase: { ID: 0x4101, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3366
+ schneiderPartialApparentEnergyL1Phase: { ID: 0x4102, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3367
+ schneiderActiveEnergyL1Phase: { ID: 0x4103, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3368
+ schneiderReactiveEnergyL1Phase: { ID: 0x4104, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3369
+ schneiderApparentEnergyL1Phase: { ID: 0x4105, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3370
+ schneiderPartialActiveEnergyL2Phase: { ID: 0x4200, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3371
+ schneiderPartialReactiveEnergyL2Phase: { ID: 0x4201, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3372
+ schneiderPartialApparentEnergyL2Phase: { ID: 0x4202, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3373
+ schneiderActiveEnergyL2Phase: { ID: 0x4203, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3374
+ schneiderReactiveEnergyL2Phase: { ID: 0x4204, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3375
+ schneiderApparentEnergyL2Phase: { ID: 0x4205, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3376
+ schneiderPartialActiveEnergyL3Phase: { ID: 0x4300, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3377
+ schneiderPartialReactiveEnergyL3Phase: { ID: 0x4301, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3378
+ schneiderPartialApparentEnergyL3Phase: { ID: 0x4302, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3379
+ schneiderActiveEnergyL3Phase: { ID: 0x4303, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3380
+ schneiderReactiveEnergyL3Phase: { ID: 0x4304, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3381
+ schneiderApparentEnergyL3Phase: { ID: 0x4305, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3382
+ schneiderActiveEnergyMultiplier: { ID: 0x4400, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3383
+ schneiderActiveEnergyDivisor: { ID: 0x4401, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3384
+ schneiderReactiveEnergyMultiplier: { ID: 0x4402, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3385
+ schneiderReactiveEnergyDivisor: { ID: 0x4403, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3386
+ schneiderApparentEnergyMultiplier: { ID: 0x4404, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3387
+ schneiderApparentEnergyDivisor: { ID: 0x4405, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3388
+ schneiderEnergyResetDateTime: { ID: 0x4501, type: dataType_1.default.utc, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3389
+ schneiderEnergyCountersReportingPeriod: { ID: 0x4600, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3384
3390
  },
3385
3391
  commands: {
3386
3392
  getProfile: {
@@ -3768,27 +3774,27 @@ const Cluster = {
3768
3774
  rmsExtremeUnderVoltagePeriodPhC: { ID: 2581, type: dataType_1.default.uint16 },
3769
3775
  rmsVoltageSagPeriodPhC: { ID: 2582, type: dataType_1.default.uint16 },
3770
3776
  rmsVoltageSwellPeriodPhC: { ID: 2583, type: dataType_1.default.uint16 },
3771
- schneiderActivePowerDemandTotal: { ID: 0x4300, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3772
- schneiderReactivePowerDemandTotal: { ID: 0x4303, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3773
- schneiderApparentPowerDemandTotal: { ID: 0x4318, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3774
- schneiderDemandIntervalDuration: { ID: 0x4319, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3775
- schneiderDemandDateTime: { ID: 0x4320, type: dataType_1.default.utc, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3776
- schneiderActivePowerDemandPhase1: { ID: 0x4509, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3777
- schneiderReactivePowerDemandPhase1: { ID: 0x450A, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3778
- schneiderApparentPowerDemandPhase1: { ID: 0x450B, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3779
- schneiderDemandIntervalMinimalVoltageL1: { ID: 0x4510, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3780
- schneiderDemandIntervalMaximalCurrentI1: { ID: 0x4513, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3781
- schneiderActivePowerDemandPhase2: { ID: 0x4909, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3782
- schneiderReactivePowerDemandPhase2: { ID: 0x490A, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3783
- schneiderApparentPowerDemandPhase2: { ID: 0x490B, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3784
- schneiderDemandIntervalMinimalVoltageL2: { ID: 0x4910, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3785
- schneiderDemandIntervalMaximalCurrentI2: { ID: 0x4913, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3786
- schneiderActivePowerDemandPhase3: { ID: 0x4A09, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3787
- schneiderReactivePowerDemandPhase3: { ID: 0x4A0A, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3788
- schneiderApparentPowerDemandPhase3: { ID: 0x4A0B, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3789
- schneiderDemandIntervalMinimalVoltageL3: { ID: 0x4A10, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3790
- schneiderDemandIntervalMaximalCurrentI3: { ID: 0x4A13, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3791
- schneiderCurrentSensorMultiplier: { ID: 0x4E00, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3777
+ schneiderActivePowerDemandTotal: { ID: 0x4300, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3778
+ schneiderReactivePowerDemandTotal: { ID: 0x4303, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3779
+ schneiderApparentPowerDemandTotal: { ID: 0x4318, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3780
+ schneiderDemandIntervalDuration: { ID: 0x4319, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3781
+ schneiderDemandDateTime: { ID: 0x4320, type: dataType_1.default.utc, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3782
+ schneiderActivePowerDemandPhase1: { ID: 0x4509, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3783
+ schneiderReactivePowerDemandPhase1: { ID: 0x450A, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3784
+ schneiderApparentPowerDemandPhase1: { ID: 0x450B, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3785
+ schneiderDemandIntervalMinimalVoltageL1: { ID: 0x4510, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3786
+ schneiderDemandIntervalMaximalCurrentI1: { ID: 0x4513, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3787
+ schneiderActivePowerDemandPhase2: { ID: 0x4909, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3788
+ schneiderReactivePowerDemandPhase2: { ID: 0x490A, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3789
+ schneiderApparentPowerDemandPhase2: { ID: 0x490B, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3790
+ schneiderDemandIntervalMinimalVoltageL2: { ID: 0x4910, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3791
+ schneiderDemandIntervalMaximalCurrentI2: { ID: 0x4913, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3792
+ schneiderActivePowerDemandPhase3: { ID: 0x4A09, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3793
+ schneiderReactivePowerDemandPhase3: { ID: 0x4A0A, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3794
+ schneiderApparentPowerDemandPhase3: { ID: 0x4A0B, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3795
+ schneiderDemandIntervalMinimalVoltageL3: { ID: 0x4A10, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3796
+ schneiderDemandIntervalMaximalCurrentI3: { ID: 0x4A13, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3797
+ schneiderCurrentSensorMultiplier: { ID: 0x4E00, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3792
3798
  },
3793
3799
  commands: {
3794
3800
  getProfileInfo: {
@@ -3863,12 +3869,12 @@ const Cluster = {
3863
3869
  averageMacRetryPerApsMessageSent: { ID: 283, type: dataType_1.default.uint16 },
3864
3870
  lastMessageLqi: { ID: 284, type: dataType_1.default.uint8 },
3865
3871
  lastMessageRssi: { ID: 285, type: dataType_1.default.int8 },
3866
- danfossSystemStatusCode: { ID: 0x4000, type: dataType_1.default.bitmap16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
3867
- danfossSystemStatusWater: { ID: 0x4200, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
3868
- danfossMultimasterRole: { ID: 0x4201, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
3869
- schneiderMeterStatus: { ID: 0xFF01, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3870
- schneiderDiagnosticRegister1: { ID: 0xFF02, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3871
- schneiderCommunicationQuality: { ID: 0x4000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3872
+ danfossSystemStatusCode: { ID: 0x4000, type: dataType_1.default.bitmap16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
3873
+ danfossSystemStatusWater: { ID: 0x4200, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
3874
+ danfossMultimasterRole: { ID: 0x4201, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
3875
+ schneiderMeterStatus: { ID: 0xFF01, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3876
+ schneiderDiagnosticRegister1: { ID: 0xFF02, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3877
+ schneiderCommunicationQuality: { ID: 0x4000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3872
3878
  },
3873
3879
  commands: {},
3874
3880
  commandsResponse: {},
@@ -3991,7 +3997,7 @@ const Cluster = {
3991
3997
  },
3992
3998
  manuSpecificPhilips: {
3993
3999
  ID: 0xFC00,
3994
- manufacturerCode: manufacturerCode_1.default.PHILIPS,
4000
+ manufacturerCode: manufacturerCode_1.default.SIGNIFY_NETHERLANDS_B_V,
3995
4001
  attributes: {
3996
4002
  config: { ID: 49, type: dataType_1.default.bitmap16 },
3997
4003
  },
@@ -4012,7 +4018,7 @@ const Cluster = {
4012
4018
  },
4013
4019
  manuSpecificPhilips2: {
4014
4020
  ID: 0xFC03,
4015
- manufacturerCode: manufacturerCode_1.default.PHILIPS,
4021
+ manufacturerCode: manufacturerCode_1.default.SIGNIFY_NETHERLANDS_B_V,
4016
4022
  attributes: {
4017
4023
  state: { ID: 0x0002, type: dataType_1.default.octetStr },
4018
4024
  },
@@ -4028,7 +4034,7 @@ const Cluster = {
4028
4034
  },
4029
4035
  manuSpecificSinope: {
4030
4036
  ID: 65281,
4031
- manufacturerCode: manufacturerCode_1.default.Sinope,
4037
+ manufacturerCode: manufacturerCode_1.default.SINOPE_TECHNOLOGIES,
4032
4038
  attributes: {
4033
4039
  // attribute ID :1's readable
4034
4040
  keypadLockout: { ID: 2, type: dataType_1.default.enum8 },
@@ -4094,7 +4100,7 @@ const Cluster = {
4094
4100
  },
4095
4101
  manuSpecificUbisysDimmerSetup: {
4096
4102
  ID: 0xfc01,
4097
- manufacturerCode: manufacturerCode_1.default.Ubisys,
4103
+ manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH,
4098
4104
  attributes: {
4099
4105
  capabilities: { ID: 0x0000, type: dataType_1.default.bitmap8 },
4100
4106
  status: { ID: 0x0001, type: dataType_1.default.bitmap8 },
@@ -4105,7 +4111,7 @@ const Cluster = {
4105
4111
  },
4106
4112
  manuSpecificLegrandDevices: {
4107
4113
  ID: 0xfc01,
4108
- manufacturerCode: manufacturerCode_1.default.LegrandNetatmo,
4114
+ manufacturerCode: manufacturerCode_1.default.LEGRAND_GROUP,
4109
4115
  attributes: {
4110
4116
  // attributes seems to vary depending on the device. Can't be static
4111
4117
  },
@@ -4114,7 +4120,7 @@ const Cluster = {
4114
4120
  },
4115
4121
  manuSpecificLegrandDevices2: {
4116
4122
  ID: 0xfc40,
4117
- manufacturerCode: manufacturerCode_1.default.LegrandNetatmo,
4123
+ manufacturerCode: manufacturerCode_1.default.LEGRAND_GROUP,
4118
4124
  attributes: {},
4119
4125
  commands: {
4120
4126
  command0: {
@@ -4128,7 +4134,7 @@ const Cluster = {
4128
4134
  },
4129
4135
  manuSpecificLegrandDevices3: {
4130
4136
  ID: 0xfc41,
4131
- manufacturerCode: manufacturerCode_1.default.LegrandNetatmo,
4137
+ manufacturerCode: manufacturerCode_1.default.LEGRAND_GROUP,
4132
4138
  attributes: {},
4133
4139
  commands: {
4134
4140
  command0: {
@@ -4388,19 +4394,22 @@ const Cluster = {
4388
4394
  },
4389
4395
  manuSpecificLumi: {
4390
4396
  ID: 0xFCC0,
4391
- manufacturerCode: manufacturerCode_1.default.LUMI_UNITED_TECH,
4397
+ manufacturerCode: manufacturerCode_1.default.LUMI_UNITED_TECHOLOGY_LTD_SHENZHEN,
4392
4398
  attributes: {
4393
4399
  mode: { ID: 0x0009, type: dataType_1.default.uint8 },
4394
4400
  illuminance: { ID: 0x0112, type: dataType_1.default.uint32 },
4395
4401
  displayUnit: { ID: 0x0114, type: dataType_1.default.uint8 },
4396
4402
  airQuality: { ID: 0x0129, type: dataType_1.default.uint8 },
4403
+ curtainReverse: { ID: 0x0400, type: dataType_1.default.boolean },
4404
+ curtainHandOpen: { ID: 0x0401, type: dataType_1.default.boolean },
4405
+ curtainCalibrated: { ID: 0x0402, type: dataType_1.default.boolean },
4397
4406
  },
4398
4407
  commands: {},
4399
4408
  commandsResponse: {}
4400
4409
  },
4401
4410
  liXeePrivate: {
4402
4411
  ID: 0xFF66,
4403
- manufacturerCode: manufacturerCode_1.default.JENNIC,
4412
+ manufacturerCode: manufacturerCode_1.default.NXP_SEMICONDUCTORS,
4404
4413
  attributes: {
4405
4414
  currentTarif: { ID: 0x0000, type: dataType_1.default.charStr },
4406
4415
  tomorrowColor: { ID: 0x0001, type: dataType_1.default.charStr },
@@ -4462,8 +4471,9 @@ const Cluster = {
4462
4471
  manuSpecificTuya_3: {
4463
4472
  ID: 0xe001,
4464
4473
  attributes: {
4465
- switchType: { ID: 0xd030, type: dataType_1.default.enum8 },
4466
4474
  powerOnBehavior: { ID: 0xd010, type: dataType_1.default.enum8 },
4475
+ switchMode: { ID: 0xd020, type: dataType_1.default.enum8 },
4476
+ switchType: { ID: 0xd030, type: dataType_1.default.enum8 },
4467
4477
  },
4468
4478
  commands: {
4469
4479
  setOptions1: {
@@ -4489,7 +4499,7 @@ const Cluster = {
4489
4499
  },
4490
4500
  manuSpecificCentraliteHumidity: {
4491
4501
  ID: 0xFC45,
4492
- manufacturerCode: manufacturerCode_1.default.Centralite,
4502
+ manufacturerCode: manufacturerCode_1.default.CENTRALITE_SYSTEMS_INC,
4493
4503
  attributes: {
4494
4504
  measuredValue: { ID: 0, type: dataType_1.default.uint16 },
4495
4505
  },
@@ -4498,7 +4508,7 @@ const Cluster = {
4498
4508
  },
4499
4509
  manuSpecificSmartThingsArrivalSensor: {
4500
4510
  ID: 0xFC05,
4501
- manufacturerCode: manufacturerCode_1.default.SmartThings,
4511
+ manufacturerCode: manufacturerCode_1.default.SMARTTHINGS_INC,
4502
4512
  attributes: {},
4503
4513
  commands: {},
4504
4514
  commandsResponse: {
@@ -4510,7 +4520,7 @@ const Cluster = {
4510
4520
  },
4511
4521
  manuSpecificSamsungAccelerometer: {
4512
4522
  ID: 0xFC02,
4513
- manufacturerCode: manufacturerCode_1.default.SmartThings,
4523
+ manufacturerCode: manufacturerCode_1.default.SMARTTHINGS_INC,
4514
4524
  attributes: {
4515
4525
  motion_threshold_multiplier: { ID: 0, type: dataType_1.default.uint8 },
4516
4526
  motion_threshold: { ID: 2, type: dataType_1.default.uint16 },
@@ -4525,7 +4535,7 @@ const Cluster = {
4525
4535
  heimanSpecificFormaldehydeMeasurement: {
4526
4536
  // from HS2AQ-3.0海曼智能空气质量检测仪API文档-V01
4527
4537
  ID: 0x042b,
4528
- manufacturerCode: manufacturerCode_1.default.Heiman,
4538
+ manufacturerCode: manufacturerCode_1.default.HEIMAN_TECHNOLOGY_CO_LTD,
4529
4539
  attributes: {
4530
4540
  measuredValue: { ID: 0x0000, type: dataType_1.default.uint16 },
4531
4541
  measuredMinValue: { ID: 0x0001, type: dataType_1.default.uint16 },
@@ -4538,7 +4548,7 @@ const Cluster = {
4538
4548
  heimanSpecificAirQuality: {
4539
4549
  // from HS2AQ-3.0海曼智能空气质量检测仪API文档-V01
4540
4550
  ID: 0xfc81,
4541
- manufacturerCode: manufacturerCode_1.default.Heiman,
4551
+ manufacturerCode: manufacturerCode_1.default.HEIMAN_TECHNOLOGY_CO_LTD,
4542
4552
  attributes: {
4543
4553
  language: { ID: 0xf000, type: dataType_1.default.uint8 },
4544
4554
  unitOfMeasure: { ID: 0xf001, type: dataType_1.default.uint8 },
@@ -4575,7 +4585,7 @@ const Cluster = {
4575
4585
  heimanSpecificScenes: {
4576
4586
  // from HS2SS-3.0海曼智能情景开关API文档-V01
4577
4587
  ID: 0xfc80,
4578
- manufacturerCode: manufacturerCode_1.default.Heiman,
4588
+ manufacturerCode: manufacturerCode_1.default.HEIMAN_TECHNOLOGY_CO_LTD,
4579
4589
  attributes: {},
4580
4590
  commands: {
4581
4591
  cinema: {
@@ -4642,7 +4652,7 @@ const Cluster = {
4642
4652
  heimanSpecificInfraRedRemote: {
4643
4653
  // from HS2IRC-3.0海曼智能红外转发控制器API-V01文档
4644
4654
  ID: 0xfc82,
4645
- manufacturerCode: manufacturerCode_1.default.Heiman,
4655
+ manufacturerCode: manufacturerCode_1.default.HEIMAN_TECHNOLOGY_CO_LTD,
4646
4656
  attributes: {},
4647
4657
  commands: {
4648
4658
  sendKey: {
@@ -4721,7 +4731,7 @@ const Cluster = {
4721
4731
  },
4722
4732
  develcoSpecificAirQuality: {
4723
4733
  ID: 0xFC03,
4724
- manufacturerCode: manufacturerCode_1.default.Develco,
4734
+ manufacturerCode: manufacturerCode_1.default.DEVELCO,
4725
4735
  attributes: {
4726
4736
  measuredValue: { ID: 0x0000, type: dataType_1.default.uint16 },
4727
4737
  minMeasuredValue: { ID: 0x0001, type: dataType_1.default.uint16 },
@@ -4733,7 +4743,7 @@ const Cluster = {
4733
4743
  },
4734
4744
  schneiderSpecificPilotMode: {
4735
4745
  ID: 0xFF23,
4736
- manufacturerCode: manufacturerCode_1.default.SCHNEIDER,
4746
+ manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC,
4737
4747
  attributes: {
4738
4748
  pilotMode: { ID: 0x0031, type: dataType_1.default.enum8 },
4739
4749
  },
@@ -4742,7 +4752,7 @@ const Cluster = {
4742
4752
  },
4743
4753
  elkoOccupancySettingClusterServer: {
4744
4754
  ID: 0xFF19,
4745
- manufacturerCode: manufacturerCode_1.default.ELKO,
4755
+ manufacturerCode: manufacturerCode_1.default.ADEO,
4746
4756
  attributes: {
4747
4757
  AmbienceLightThreshold: { ID: 0x0000, type: dataType_1.default.uint16 },
4748
4758
  OccupancyActions: { ID: 0x0001, type: dataType_1.default.enum8 },
@@ -4754,7 +4764,7 @@ const Cluster = {
4754
4764
  },
4755
4765
  elkoSwitchConfigurationClusterServer: {
4756
4766
  ID: 0xFF17,
4757
- manufacturerCode: manufacturerCode_1.default.ELKO,
4767
+ manufacturerCode: manufacturerCode_1.default.ADEO,
4758
4768
  attributes: {
4759
4769
  SwitchIndication: { ID: 0x0000, type: dataType_1.default.enum8 },
4760
4770
  UpSceneID: { ID: 0x0010, type: dataType_1.default.uint8 },
@@ -4768,7 +4778,7 @@ const Cluster = {
4768
4778
  },
4769
4779
  manuSpecificSchneiderLightSwitchConfiguration: {
4770
4780
  ID: 0xFF17,
4771
- manufacturerCode: manufacturerCode_1.default.SCHNEIDER,
4781
+ manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC,
4772
4782
  attributes: {
4773
4783
  ledIndication: { ID: 0x0000, type: dataType_1.default.enum8 },
4774
4784
  upSceneID: { ID: 0x0010, type: dataType_1.default.uint8 },
@@ -4782,7 +4792,7 @@ const Cluster = {
4782
4792
  },
4783
4793
  manuSpecificSchneiderFanSwitchConfiguration: {
4784
4794
  ID: 0xFC04,
4785
- manufacturerCode: manufacturerCode_1.default.SCHNEIDER,
4795
+ manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC,
4786
4796
  attributes: {
4787
4797
  ledIndication: { ID: 0x0002, type: dataType_1.default.uint8 },
4788
4798
  ledOrientation: { ID: 0x0060, type: dataType_1.default.uint8 },
@@ -4996,7 +5006,7 @@ const Cluster = {
4996
5006
  },
4997
5007
  owonClearMetering: {
4998
5008
  ID: 0xFFE0,
4999
- manufacturerCode: manufacturerCode_1.default.OWON,
5009
+ manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC,
5000
5010
  attributes: {},
5001
5011
  commands: {
5002
5012
  owonClearMeasurementData: {
@@ -5105,7 +5115,7 @@ const Cluster = {
5105
5115
  },
5106
5116
  manuSpecificBosch: {
5107
5117
  ID: 0xe000,
5108
- manufacturerCode: manufacturerCode_1.default.Bosch,
5118
+ manufacturerCode: manufacturerCode_1.default.BOSCH_SECURITY_SYSTEMS_INC,
5109
5119
  attributes: {
5110
5120
  sensitivity: { ID: 0x4003, type: 0x21 },
5111
5121
  },
@@ -5119,7 +5129,7 @@ const Cluster = {
5119
5129
  },
5120
5130
  manuSpecificBosch3: {
5121
5131
  ID: 0xe002,
5122
- manufacturerCode: manufacturerCode_1.default.Bosch,
5132
+ manufacturerCode: manufacturerCode_1.default.BOSCH_SECURITY_SYSTEMS_INC,
5123
5133
  attributes: {
5124
5134
  humidity: { ID: 0x4000, type: 0x21 },
5125
5135
  unknown1: { ID: 0x4001, type: 0x21 },
@@ -5140,7 +5150,7 @@ const Cluster = {
5140
5150
  },
5141
5151
  manuSpecificBosch5: {
5142
5152
  ID: 0xe004,
5143
- manufacturerCode: manufacturerCode_1.default.Bosch,
5153
+ manufacturerCode: manufacturerCode_1.default.BOSCH_SECURITY_SYSTEMS_INC,
5144
5154
  attributes: {
5145
5155
  unknown_attribute: { ID: 0x4000, type: dataType_1.default.bitmap8 }, // 0,1 ??? read during pairing
5146
5156
  pre_alarm: { ID: 0x4001, type: dataType_1.default.bitmap8 }, // 0,1 on/off
@@ -5150,7 +5160,7 @@ const Cluster = {
5150
5160
  },
5151
5161
  manuSpecificBosch7: {
5152
5162
  ID: 0xe006,
5153
- manufacturerCode: manufacturerCode_1.default.Bosch,
5163
+ manufacturerCode: manufacturerCode_1.default.BOSCH_SECURITY_SYSTEMS_INC,
5154
5164
  attributes: {
5155
5165
  unknown1: { ID: 0x5003, type: 0x28 }, // perhaps signal strength? -7?
5156
5166
  unknown2: { ID: 0x5004, type: 0x20 }, // ????
@@ -5166,7 +5176,7 @@ const Cluster = {
5166
5176
  },
5167
5177
  manuSpecificBosch8: {
5168
5178
  ID: 0xe007,
5169
- manufacturerCode: manufacturerCode_1.default.Bosch,
5179
+ manufacturerCode: manufacturerCode_1.default.BOSCH_SECURITY_SYSTEMS_INC,
5170
5180
  attributes: {
5171
5181
  alarm_status: { ID: 0x5000, type: dataType_1.default.bitmap32 },
5172
5182
  },
@@ -5182,7 +5192,7 @@ const Cluster = {
5182
5192
  },
5183
5193
  manuSpecificBosch9: {
5184
5194
  ID: 0xfca1,
5185
- manufacturerCode: manufacturerCode_1.default.Bosch,
5195
+ manufacturerCode: manufacturerCode_1.default.BOSCH_SECURITY_SYSTEMS_INC,
5186
5196
  attributes: {},
5187
5197
  commands: {
5188
5198
  confirmButtonPressed: {
@@ -5202,7 +5212,7 @@ const Cluster = {
5202
5212
  },
5203
5213
  manuSpecificBosch10: {
5204
5214
  ID: 0xfca0,
5205
- manufacturerCode: manufacturerCode_1.default.Bosch,
5215
+ manufacturerCode: manufacturerCode_1.default.BOSCH_SECURITY_SYSTEMS_INC,
5206
5216
  attributes: {
5207
5217
  deviceMode: { ID: 0x0000, type: dataType_1.default.enum8 },
5208
5218
  switchType: { ID: 0x0001, type: dataType_1.default.enum8 },
@@ -5471,7 +5481,7 @@ const Cluster = {
5471
5481
  },
5472
5482
  manuSpecificNodOnPilotWire: {
5473
5483
  ID: 0xFC00,
5474
- manufacturerCode: manufacturerCode_1.default.NodOn,
5484
+ manufacturerCode: manufacturerCode_1.default.NODON,
5475
5485
  attributes: {
5476
5486
  mode: { ID: 0x0000, type: dataType_1.default.uint8 }
5477
5487
  },