zigbee-herdsman 0.36.1 → 0.37.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (36) hide show
  1. package/.release-please-manifest.json +1 -1
  2. package/CHANGELOG.md +24 -0
  3. package/dist/adapter/ember/adapter/emberAdapter.d.ts +0 -15
  4. package/dist/adapter/ember/adapter/emberAdapter.d.ts.map +1 -1
  5. package/dist/adapter/ember/adapter/emberAdapter.js +12 -110
  6. package/dist/adapter/ember/adapter/emberAdapter.js.map +1 -1
  7. package/dist/adapter/ember/adapter/endpoints.d.ts +5 -3
  8. package/dist/adapter/ember/adapter/endpoints.d.ts.map +1 -1
  9. package/dist/adapter/ember/adapter/endpoints.js +4 -0
  10. package/dist/adapter/ember/adapter/endpoints.js.map +1 -1
  11. package/dist/adapter/ember/enums.d.ts +12 -14
  12. package/dist/adapter/ember/enums.d.ts.map +1 -1
  13. package/dist/adapter/ember/enums.js +12 -14
  14. package/dist/adapter/ember/enums.js.map +1 -1
  15. package/dist/adapter/ember/types.d.ts +9 -9
  16. package/dist/adapter/ember/types.d.ts.map +1 -1
  17. package/dist/controller/controller.d.ts.map +1 -1
  18. package/dist/controller/controller.js +5 -3
  19. package/dist/controller/controller.js.map +1 -1
  20. package/dist/controller/helpers/zclFrameConverter.js +1 -1
  21. package/dist/controller/helpers/zclFrameConverter.js.map +1 -1
  22. package/dist/controller/model/group.d.ts.map +1 -1
  23. package/dist/controller/model/group.js +3 -0
  24. package/dist/controller/model/group.js.map +1 -1
  25. package/dist/zcl/definition/cluster.d.ts.map +1 -1
  26. package/dist/zcl/definition/cluster.js +233 -230
  27. package/dist/zcl/definition/cluster.js.map +1 -1
  28. package/dist/zcl/definition/manufacturerCode.d.ts +724 -1077
  29. package/dist/zcl/definition/manufacturerCode.d.ts.map +1 -1
  30. package/dist/zcl/definition/manufacturerCode.js +727 -1080
  31. package/dist/zcl/definition/manufacturerCode.js.map +1 -1
  32. package/dist/zcl/definition/status.d.ts +46 -15
  33. package/dist/zcl/definition/status.d.ts.map +1 -1
  34. package/dist/zcl/definition/status.js +36 -4
  35. package/dist/zcl/definition/status.js.map +1 -1
  36. package/package.json +2 -2
@@ -29,7 +29,7 @@ const Cluster = {
29
29
  develcoPrimarySwVersion: { ID: 0x8000, type: dataType_1.default.octetStr, manufacturerCode: manufacturerCode_1.default.DEVELCO },
30
30
  develcoPrimaryHwVersion: { ID: 0x8020, type: dataType_1.default.octetStr, manufacturerCode: manufacturerCode_1.default.DEVELCO },
31
31
  develcoLedControl: { ID: 0x8100, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.DEVELCO },
32
- schneiderMeterRadioPower: { ID: 0xE200, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
32
+ schneiderMeterRadioPower: { ID: 0xE200, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
33
33
  },
34
34
  commands: {
35
35
  resetFactDefault: {
@@ -429,9 +429,9 @@ const Cluster = {
429
429
  tuyaBacklightMode: { ID: 0x8001, type: dataType_1.default.enum8 },
430
430
  moesStartUpOnOff: { ID: 0x8002, type: dataType_1.default.enum8 },
431
431
  tuyaOperationMode: { ID: 0x8004, type: dataType_1.default.enum8 },
432
- elkoPreWarningTime: { ID: 0xE000, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ELKO },
433
- elkoOnTimeReload: { ID: 0xE001, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.ELKO },
434
- elkoOnTimeReloadOptions: { ID: 0xE002, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.ELKO },
432
+ elkoPreWarningTime: { ID: 0xE000, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ADEO },
433
+ elkoOnTimeReload: { ID: 0xE001, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.ADEO },
434
+ elkoOnTimeReloadOptions: { ID: 0xE002, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.ADEO },
435
435
  nodonTransitionTime: { ID: 0x0001, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.NODON },
436
436
  },
437
437
  commands: {
@@ -493,21 +493,21 @@ const Cluster = {
493
493
  offTransitionTime: { ID: 19, type: dataType_1.default.uint16 },
494
494
  defaultMoveRate: { ID: 20, type: dataType_1.default.uint16 },
495
495
  startUpCurrentLevel: { ID: 16384, type: dataType_1.default.uint8 },
496
- elkoStartUpCurrentLevel: { ID: 0x4000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.ELKO },
497
- ubisysMinimumOnLevel: { ID: 0x0000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
498
- ubisysValveType: { ID: 0x0001, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.Ubisys },
499
- ubisysCyclePeriod: { ID: 0x0002, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
500
- ubisysSeason: { ID: 0x0003, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.Ubisys },
501
- ubisysBackupLevel: { ID: 0x0004, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
502
- ubisysAlternateBackupLevel: { ID: 0x0005, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
503
- ubisysLowerRange: { ID: 0x0006, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
504
- ubisysUpperRange: { ID: 0x0007, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
505
- ubisysPumpThresholdOn: { ID: 0x0008, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
506
- ubisysPumpThresholdOff: { ID: 0x0009, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
507
- ubisysHeatingDemandEnableThreshold: { ID: 0x000A, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
508
- ubisysHeatingDemandDisableThreshold: { ID: 0x000B, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
509
- ubisysCoolingDemandEnableThreshold: { ID: 0x000C, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
510
- ubisysCoolingDemandDisableThreshold: { ID: 0x000D, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
496
+ elkoStartUpCurrentLevel: { ID: 0x4000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.ADEO },
497
+ ubisysMinimumOnLevel: { ID: 0x0000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
498
+ ubisysValveType: { ID: 0x0001, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
499
+ ubisysCyclePeriod: { ID: 0x0002, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
500
+ ubisysSeason: { ID: 0x0003, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
501
+ ubisysBackupLevel: { ID: 0x0004, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
502
+ ubisysAlternateBackupLevel: { ID: 0x0005, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
503
+ ubisysLowerRange: { ID: 0x0006, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
504
+ ubisysUpperRange: { ID: 0x0007, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
505
+ ubisysPumpThresholdOn: { ID: 0x0008, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
506
+ ubisysPumpThresholdOff: { ID: 0x0009, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
507
+ ubisysHeatingDemandEnableThreshold: { ID: 0x000A, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
508
+ ubisysHeatingDemandDisableThreshold: { ID: 0x000B, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
509
+ ubisysCoolingDemandEnableThreshold: { ID: 0x000C, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
510
+ ubisysCoolingDemandDisableThreshold: { ID: 0x000D, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
511
511
  },
512
512
  commands: {
513
513
  moveToLevel: {
@@ -1746,30 +1746,30 @@ const Cluster = {
1746
1746
  windowCoveringMode: { ID: 23, type: dataType_1.default.bitmap8 },
1747
1747
  intermediateSetpointsLift: { ID: 24, type: dataType_1.default.octetStr },
1748
1748
  intermediateSetpointsTilt: { ID: 25, type: dataType_1.default.octetStr },
1749
- ubisysTurnaroundGuardTime: { ID: 0x1000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
1750
- ubisysLiftToTiltTransitionSteps: { ID: 0x1001, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1751
- ubisysTotalSteps: { ID: 0x1002, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1752
- ubisysLiftToTiltTransitionSteps2: { ID: 0x1003, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1753
- ubisysTotalSteps2: { ID: 0x1004, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1754
- ubisysAdditionalSteps: { ID: 0x1005, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
1755
- ubisysInactivePowerThreshold: { ID: 0x1006, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1756
- ubisysStartupSteps: { ID: 0x1007, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1749
+ ubisysTurnaroundGuardTime: { ID: 0x1000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1750
+ ubisysLiftToTiltTransitionSteps: { ID: 0x1001, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1751
+ ubisysTotalSteps: { ID: 0x1002, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1752
+ ubisysLiftToTiltTransitionSteps2: { ID: 0x1003, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1753
+ ubisysTotalSteps2: { ID: 0x1004, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1754
+ ubisysAdditionalSteps: { ID: 0x1005, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1755
+ ubisysInactivePowerThreshold: { ID: 0x1006, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1756
+ ubisysStartupSteps: { ID: 0x1007, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1757
1757
  tuyaMovingState: { ID: 0xf000, type: dataType_1.default.enum8 },
1758
1758
  tuyaCalibration: { ID: 0xf001, type: dataType_1.default.enum8 },
1759
- stepPositionLift: { ID: 0xf001, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LegrandNetatmo },
1759
+ stepPositionLift: { ID: 0xf001, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LEGRAND_GROUP },
1760
1760
  tuyaMotorReversal: { ID: 0xf002, type: dataType_1.default.enum8 },
1761
- calibrationMode: { ID: 0xf002, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LegrandNetatmo },
1761
+ calibrationMode: { ID: 0xf002, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LEGRAND_GROUP },
1762
1762
  moesCalibrationTime: { ID: 0xf003, type: dataType_1.default.uint16 },
1763
- targetPositionTiltPercentage: { ID: 0xf003, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LegrandNetatmo },
1764
- stepPositionTilt: { ID: 0xf004, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LegrandNetatmo },
1765
- elkoDriveCloseDuration: { ID: 0xE000, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ELKO },
1766
- elkoProtectionStatus: { ID: 0xE010, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.ELKO },
1767
- elkoProtectionSensor: { ID: 0xE013, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.ELKO },
1768
- elkoSunProtectionIlluminanceThreshold: { ID: 0xE012, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ELKO },
1769
- elkoLiftDriveUpTime: { ID: 0xE014, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ELKO },
1770
- elkoLiftDriveDownTime: { ID: 0xE015, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ELKO },
1771
- elkoTiltOpenCloseAndStepTime: { ID: 0xE016, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ELKO },
1772
- elkoTiltPositionPercentageAfterMoveToLevel: { ID: 0xE017, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.ELKO },
1763
+ targetPositionTiltPercentage: { ID: 0xf003, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LEGRAND_GROUP },
1764
+ stepPositionTilt: { ID: 0xf004, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.LEGRAND_GROUP },
1765
+ elkoDriveCloseDuration: { ID: 0xE000, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ADEO },
1766
+ elkoProtectionStatus: { ID: 0xE010, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.ADEO },
1767
+ elkoProtectionSensor: { ID: 0xE013, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.ADEO },
1768
+ elkoSunProtectionIlluminanceThreshold: { ID: 0xE012, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ADEO },
1769
+ elkoLiftDriveUpTime: { ID: 0xE014, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ADEO },
1770
+ elkoLiftDriveDownTime: { ID: 0xE015, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ADEO },
1771
+ elkoTiltOpenCloseAndStepTime: { ID: 0xE016, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ADEO },
1772
+ elkoTiltPositionPercentageAfterMoveToLevel: { ID: 0xE017, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.ADEO },
1773
1773
  },
1774
1774
  commands: {
1775
1775
  upOpen: {
@@ -1923,43 +1923,43 @@ const Cluster = {
1923
1923
  acLouverPosition: { ID: 69, type: dataType_1.default.enum8 },
1924
1924
  acCollTemp: { ID: 70, type: dataType_1.default.int16 },
1925
1925
  acCapacityFormat: { ID: 71, type: dataType_1.default.enum8 },
1926
- SinopeOccupancy: { ID: 1024, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.Sinope },
1927
- SinopeMainCycleOutput: { ID: 1025, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Sinope },
1928
- SinopeBacklight: { ID: 1026, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.Sinope },
1929
- SinopeAuxCycleOutput: { ID: 1028, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.Sinope },
1926
+ SinopeOccupancy: { ID: 1024, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.SINOPE_TECHNOLOGIES },
1927
+ SinopeMainCycleOutput: { ID: 1025, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SINOPE_TECHNOLOGIES },
1928
+ SinopeBacklight: { ID: 1026, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.SINOPE_TECHNOLOGIES },
1929
+ SinopeAuxCycleOutput: { ID: 1028, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SINOPE_TECHNOLOGIES },
1930
1930
  StelproSystemMode: { ID: 0x401c, type: dataType_1.default.enum8 },
1931
1931
  StelproOutdoorTemp: { ID: 0x4001, type: dataType_1.default.int16 },
1932
- viessmannWindowOpenInternal: { ID: 0x4000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.VIESSMAN_ELEKTRO },
1933
- viessmannWindowOpenForce: { ID: 0x4003, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.VIESSMAN_ELEKTRO },
1934
- viessmannAssemblyMode: { ID: 0x4012, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.VIESSMAN_ELEKTRO },
1935
- schneiderWiserSpecific: { ID: 0xe110, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
1936
- danfossWindowOpenInternal: { ID: 0x4000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1937
- danfossWindowOpenExternal: { ID: 0x4003, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1938
- danfossDayOfWeek: { ID: 0x4010, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1939
- danfossTriggerTime: { ID: 0x4011, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1940
- danfossMountedModeActive: { ID: 0x4012, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1941
- danfossMountedModeControl: { ID: 0x4013, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1942
- danfossThermostatOrientation: { ID: 0x4014, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1943
- danfossExternalMeasuredRoomSensor: { ID: 0x4015, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1944
- danfossRadiatorCovered: { ID: 0x4016, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1945
- danfossAlgorithmScaleFactor: { ID: 0x4020, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1946
- danfossHeatAvailable: { ID: 0x4030, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1947
- danfossHeatRequired: { ID: 0x4031, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1948
- danfossLoadBalancingEnable: { ID: 0x4032, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1949
- danfossLoadRoomMean: { ID: 0x4040, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1950
- danfossLoadEstimate: { ID: 0x404a, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1951
- danfossRegulationSetpointOffset: { ID: 0x404b, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1952
- danfossAdaptionRunControl: { ID: 0x404c, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1953
- danfossAdaptionRunStatus: { ID: 0x404d, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1954
- danfossAdaptionRunSettings: { ID: 0x404e, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1955
- danfossPreheatStatus: { ID: 0x404f, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1956
- danfossPreheatTime: { ID: 0x4050, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1957
- danfossWindowOpenFeatureEnable: { ID: 0x4051, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1958
- danfossRoomStatusCode: { ID: 0x4100, type: dataType_1.default.bitmap16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1959
- danfossOutputStatus: { ID: 0x4110, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1960
- danfossRoomFloorSensorMode: { ID: 0x4120, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1961
- danfossFloorMinSetpoint: { ID: 0x4121, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1962
- danfossFloorMaxSetpoint: { ID: 0x4122, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
1932
+ viessmannWindowOpenInternal: { ID: 0x4000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.VIESSMANN_ELEKTRONIK_GMBH },
1933
+ viessmannWindowOpenForce: { ID: 0x4003, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.VIESSMANN_ELEKTRONIK_GMBH },
1934
+ viessmannAssemblyMode: { ID: 0x4012, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.VIESSMANN_ELEKTRONIK_GMBH },
1935
+ schneiderWiserSpecific: { ID: 0xe110, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
1936
+ danfossWindowOpenInternal: { ID: 0x4000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1937
+ danfossWindowOpenExternal: { ID: 0x4003, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1938
+ danfossDayOfWeek: { ID: 0x4010, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1939
+ danfossTriggerTime: { ID: 0x4011, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1940
+ danfossMountedModeActive: { ID: 0x4012, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1941
+ danfossMountedModeControl: { ID: 0x4013, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1942
+ danfossThermostatOrientation: { ID: 0x4014, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1943
+ danfossExternalMeasuredRoomSensor: { ID: 0x4015, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1944
+ danfossRadiatorCovered: { ID: 0x4016, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1945
+ danfossAlgorithmScaleFactor: { ID: 0x4020, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1946
+ danfossHeatAvailable: { ID: 0x4030, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1947
+ danfossHeatRequired: { ID: 0x4031, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1948
+ danfossLoadBalancingEnable: { ID: 0x4032, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1949
+ danfossLoadRoomMean: { ID: 0x4040, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1950
+ danfossLoadEstimate: { ID: 0x404a, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1951
+ danfossRegulationSetpointOffset: { ID: 0x404b, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1952
+ danfossAdaptionRunControl: { ID: 0x404c, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1953
+ danfossAdaptionRunStatus: { ID: 0x404d, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1954
+ danfossAdaptionRunSettings: { ID: 0x404e, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1955
+ danfossPreheatStatus: { ID: 0x404f, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1956
+ danfossPreheatTime: { ID: 0x4050, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1957
+ danfossWindowOpenFeatureEnable: { ID: 0x4051, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1958
+ danfossRoomStatusCode: { ID: 0x4100, type: dataType_1.default.bitmap16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1959
+ danfossOutputStatus: { ID: 0x4110, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1960
+ danfossRoomFloorSensorMode: { ID: 0x4120, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1961
+ danfossFloorMinSetpoint: { ID: 0x4121, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1962
+ danfossFloorMaxSetpoint: { ID: 0x4122, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
1963
1963
  elkoLoad: { ID: 0x0401, type: dataType_1.default.uint16 },
1964
1964
  elkoDisplayText: { ID: 0x0402, type: dataType_1.default.charStr },
1965
1965
  elkoSensor: { ID: 0x0403, type: dataType_1.default.enum8 },
@@ -1978,24 +1978,24 @@ const Cluster = {
1978
1978
  elkoCalibration: { ID: 0x0417, type: dataType_1.default.int8 },
1979
1979
  elkoLastMessageId: { ID: 0x0418, type: dataType_1.default.uint8 },
1980
1980
  elkoLastMessageStatus: { ID: 0x0419, type: dataType_1.default.uint8 },
1981
- fourNoksHysteresisHigh: { ID: 0x0101, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default._4_NOKS },
1982
- fourNoksHysteresisLow: { ID: 0x0102, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default._4_NOKS },
1983
- ubisysClassBTemperatureOffset: { ID: 0x0000, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.Ubisys },
1984
- ubisysReturnFlowTemperatureWeight: { ID: 0x0001, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.Ubisys },
1985
- ubisysRawOutdoorTemperature: { ID: 0x0002, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.Ubisys },
1986
- ubisysRawLocalTemperatureA: { ID: 0x0003, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.Ubisys },
1987
- ubisysRawLocalTemperatureB: { ID: 0x0004, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.Ubisys },
1988
- ubisysRawForwardFlowTemperature: { ID: 0x0005, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.Ubisys },
1989
- ubisysRawReturnFlowTemperature: { ID: 0x0006, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.Ubisys },
1990
- ubisysInstalledExtensions: { ID: 0x0007, type: dataType_1.default.bitmap64, manufacturerCode: manufacturerCode_1.default.Ubisys },
1991
- ubisysTemperatureOffset: { ID: 0x0010, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.Ubisys },
1992
- ubisysDefaultOccupiedHeatingSetpoint: { ID: 0x0011, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1993
- ubisysVacationMode: { ID: 0x0012, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.Ubisys },
1994
- ubisysRemoteTemperature: { ID: 0x0013, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1995
- ubisysRemoteTemperatureValidDuration: { ID: 0x0014, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.Ubisys },
1996
- ubisysProportionalGain: { ID: 0x0020, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1997
- ubisysProportionalShift: { ID: 0x0021, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.Ubisys },
1998
- ubisysIntegralFactor: { ID: 0x0022, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.Ubisys },
1981
+ fourNoksHysteresisHigh: { ID: 0x0101, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ASTREL_GROUP_SRL },
1982
+ fourNoksHysteresisLow: { ID: 0x0102, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ASTREL_GROUP_SRL },
1983
+ ubisysClassBTemperatureOffset: { ID: 0x0000, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1984
+ ubisysReturnFlowTemperatureWeight: { ID: 0x0001, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1985
+ ubisysRawOutdoorTemperature: { ID: 0x0002, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1986
+ ubisysRawLocalTemperatureA: { ID: 0x0003, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1987
+ ubisysRawLocalTemperatureB: { ID: 0x0004, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1988
+ ubisysRawForwardFlowTemperature: { ID: 0x0005, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1989
+ ubisysRawReturnFlowTemperature: { ID: 0x0006, type: dataType_1.default.struct, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1990
+ ubisysInstalledExtensions: { ID: 0x0007, type: dataType_1.default.bitmap64, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1991
+ ubisysTemperatureOffset: { ID: 0x0010, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1992
+ ubisysDefaultOccupiedHeatingSetpoint: { ID: 0x0011, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1993
+ ubisysVacationMode: { ID: 0x0012, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1994
+ ubisysRemoteTemperature: { ID: 0x0013, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1995
+ ubisysRemoteTemperatureValidDuration: { ID: 0x0014, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1996
+ ubisysProportionalGain: { ID: 0x0020, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1997
+ ubisysProportionalShift: { ID: 0x0021, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1998
+ ubisysIntegralFactor: { ID: 0x0022, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH },
1999
1999
  },
2000
2000
  commands: {
2001
2001
  setpointRaiseLower: {
@@ -2128,7 +2128,7 @@ const Cluster = {
2128
2128
  tempDisplayMode: { ID: 0, type: dataType_1.default.enum8 },
2129
2129
  keypadLockout: { ID: 1, type: dataType_1.default.enum8 },
2130
2130
  programmingVisibility: { ID: 2, type: dataType_1.default.enum8 },
2131
- danfossViewingDirection: { ID: 0x4000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
2131
+ danfossViewingDirection: { ID: 0x4000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
2132
2132
  },
2133
2133
  commands: {},
2134
2134
  commandsResponse: {},
@@ -2412,8 +2412,8 @@ const Cluster = {
2412
2412
  lampBurnHours: { ID: 51, type: dataType_1.default.uint24 },
2413
2413
  lampAlarmMode: { ID: 52, type: dataType_1.default.bitmap8 },
2414
2414
  lampBurnHoursTripPoint: { ID: 53, type: dataType_1.default.uint24 },
2415
- elkoControlMode: { ID: 0xE000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.ELKO },
2416
- wiserControlMode: { ID: 0xE000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
2415
+ elkoControlMode: { ID: 0xE000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.ADEO },
2416
+ wiserControlMode: { ID: 0xE000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
2417
2417
  },
2418
2418
  commands: {},
2419
2419
  commandsResponse: {},
@@ -2449,7 +2449,7 @@ const Cluster = {
2449
2449
  tolerance: { ID: 3, type: dataType_1.default.uint16 },
2450
2450
  minPercentChange: { ID: 16, type: dataType_1.default.unknown },
2451
2451
  minAbsoluteChange: { ID: 17, type: dataType_1.default.unknown },
2452
- sprutTemperatureOffset: { ID: 0x6600, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.SprutDevice },
2452
+ sprutTemperatureOffset: { ID: 0x6600, type: dataType_1.default.int16, manufacturerCode: manufacturerCode_1.default.SPRUT_DEVICE },
2453
2453
  },
2454
2454
  commands: {},
2455
2455
  commandsResponse: {},
@@ -2488,7 +2488,7 @@ const Cluster = {
2488
2488
  minMeasuredValue: { ID: 1, type: dataType_1.default.uint16 },
2489
2489
  maxMeasuredValue: { ID: 2, type: dataType_1.default.uint16 },
2490
2490
  tolerance: { ID: 3, type: dataType_1.default.uint16 },
2491
- sprutHeater: { ID: 0x6600, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.SprutDevice },
2491
+ sprutHeater: { ID: 0x6600, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.SPRUT_DEVICE },
2492
2492
  },
2493
2493
  commands: {},
2494
2494
  commandsResponse: {},
@@ -2504,12 +2504,12 @@ const Cluster = {
2504
2504
  ultrasonicOToUDelay: { ID: 32, type: dataType_1.default.uint16 },
2505
2505
  ultrasonicUToODelay: { ID: 33, type: dataType_1.default.uint16 },
2506
2506
  ultrasonicUToOThreshold: { ID: 34, type: dataType_1.default.uint8 },
2507
- elkoOccupancyDfltOperationMode: { ID: 0xE000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.ELKO },
2508
- elkoOccupancyOperationMode: { ID: 0xE001, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.ELKO },
2509
- elkoForceOffTimeout: { ID: 0xE002, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ELKO },
2510
- elkoOccupancySensitivity: { ID: 0xE003, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.ELKO },
2511
- sprutOccupancyLevel: { ID: 0x6600, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SprutDevice },
2512
- sprutOccupancySensitivity: { ID: 0x6601, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SprutDevice },
2507
+ elkoOccupancyDfltOperationMode: { ID: 0xE000, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.ADEO },
2508
+ elkoOccupancyOperationMode: { ID: 0xE001, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.ADEO },
2509
+ elkoForceOffTimeout: { ID: 0xE002, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.ADEO },
2510
+ elkoOccupancySensitivity: { ID: 0xE003, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.ADEO },
2511
+ sprutOccupancyLevel: { ID: 0x6600, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SPRUT_DEVICE },
2512
+ sprutOccupancySensitivity: { ID: 0x6601, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SPRUT_DEVICE },
2513
2513
  },
2514
2514
  commands: {},
2515
2515
  commandsResponse: {},
@@ -2542,8 +2542,8 @@ const Cluster = {
2542
2542
  measuredValue: { ID: 0, type: dataType_1.default.singlePrec },
2543
2543
  minMeasuredValue: { ID: 1, type: dataType_1.default.singlePrec },
2544
2544
  maxMeasuredValue: { ID: 2, type: dataType_1.default.singlePrec },
2545
- sprutCO2Calibration: { ID: 0x6600, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.SprutDevice },
2546
- sprutCO2AutoCalibration: { ID: 0x6601, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.SprutDevice },
2545
+ sprutCO2Calibration: { ID: 0x6600, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.SPRUT_DEVICE },
2546
+ sprutCO2AutoCalibration: { ID: 0x6601, type: dataType_1.default.boolean, manufacturerCode: manufacturerCode_1.default.SPRUT_DEVICE },
2547
2547
  },
2548
2548
  commands: {},
2549
2549
  commandsResponse: {},
@@ -3314,73 +3314,73 @@ const Cluster = {
3314
3314
  develcoPulseConfiguration: { ID: 0x0300, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.DEVELCO },
3315
3315
  develcoCurrentSummation: { ID: 0x0301, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.DEVELCO },
3316
3316
  develcoInterfaceMode: { ID: 0x0302, type: dataType_1.default.enum16, manufacturerCode: manufacturerCode_1.default.DEVELCO },
3317
- owonL1PhasePower: { ID: 0x2000, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON },
3318
- owonL2PhasePower: { ID: 0x2001, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON },
3319
- owonL3PhasePower: { ID: 0x2002, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON },
3320
- owonL1PhaseReactivePower: { ID: 0x2100, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON },
3321
- owonL2PhaseReactivePower: { ID: 0x2101, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON },
3322
- owonL3PhaseReactivePower: { ID: 0x2102, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON },
3323
- owonReactivePowerSum: { ID: 0x2103, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON },
3324
- owonL1PhaseVoltage: { ID: 0x3000, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3325
- owonL2PhaseVoltage: { ID: 0x3001, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3326
- owonL3PhaseVoltage: { ID: 0x3002, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3327
- owonL1PhaseCurrent: { ID: 0x3100, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3328
- owonL2PhaseCurrent: { ID: 0x3101, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3329
- owonL3PhaseCurrent: { ID: 0x3102, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3330
- owonCurrentSum: { ID: 0x3103, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3331
- owonLeakageCurrent: { ID: 0x3104, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON },
3332
- owonL1Energy: { ID: 0x4000, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON },
3333
- owonL2Energy: { ID: 0x4001, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON },
3334
- owonL3Energy: { ID: 0x4002, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON },
3335
- owonL1ReactiveEnergy: { ID: 0x4100, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON },
3336
- owonL2ReactiveEnergy: { ID: 0x4101, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON },
3337
- owonL3ReactiveEnergy: { ID: 0x4102, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON },
3338
- owonReactiveEnergySum: { ID: 0x4103, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON },
3339
- owonL1PowerFactor: { ID: 0x4104, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.OWON },
3340
- owonL2PowerFactor: { ID: 0x4105, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.OWON },
3341
- owonL3PowerFactor: { ID: 0x4106, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.OWON },
3342
- owonFrequency: { ID: 0x5005, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON },
3343
- owonReportMap: { ID: 0x1000, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.OWON },
3344
- owonLastHistoricalRecordTime: { ID: 0x5000, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON },
3345
- owonOldestHistoricalRecordTime: { ID: 0x5001, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON },
3346
- owonMinimumReportCycle: { ID: 0x5002, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON },
3347
- owonMaximumReportCycle: { ID: 0x5003, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON },
3348
- owonSentHistoricalRecordState: { ID: 0x5004, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON },
3349
- owonAccumulativeEnergyThreshold: { ID: 0x5006, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON },
3350
- owonReportMode: { ID: 0x5007, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON },
3351
- owonPercentChangeInPower: { ID: 0x5007, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON },
3352
- schneiderActiveEnergyTotal: { ID: 0x4010, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3353
- schneiderReactiveEnergyTotal: { ID: 0x4011, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3354
- schneiderApparentEnergyTotal: { ID: 0x4012, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3355
- schneiderPartialActiveEnergyTotal: { ID: 0x4014, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3356
- schneiderPartialReactiveEnergyTotal: { ID: 0x4015, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3357
- schneiderPartialApparentEnergyTotal: { ID: 0x4016, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3358
- schneiderPartialActiveEnergyL1Phase: { ID: 0x4100, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3359
- schneiderPartialReactiveEnergyL1Phase: { ID: 0x4101, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3360
- schneiderPartialApparentEnergyL1Phase: { ID: 0x4102, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3361
- schneiderActiveEnergyL1Phase: { ID: 0x4103, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3362
- schneiderReactiveEnergyL1Phase: { ID: 0x4104, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3363
- schneiderApparentEnergyL1Phase: { ID: 0x4105, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3364
- schneiderPartialActiveEnergyL2Phase: { ID: 0x4200, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3365
- schneiderPartialReactiveEnergyL2Phase: { ID: 0x4201, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3366
- schneiderPartialApparentEnergyL2Phase: { ID: 0x4202, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3367
- schneiderActiveEnergyL2Phase: { ID: 0x4203, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3368
- schneiderReactiveEnergyL2Phase: { ID: 0x4204, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3369
- schneiderApparentEnergyL2Phase: { ID: 0x4205, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3370
- schneiderPartialActiveEnergyL3Phase: { ID: 0x4300, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3371
- schneiderPartialReactiveEnergyL3Phase: { ID: 0x4301, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3372
- schneiderPartialApparentEnergyL3Phase: { ID: 0x4302, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3373
- schneiderActiveEnergyL3Phase: { ID: 0x4303, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3374
- schneiderReactiveEnergyL3Phase: { ID: 0x4304, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3375
- schneiderApparentEnergyL3Phase: { ID: 0x4305, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3376
- schneiderActiveEnergyMultiplier: { ID: 0x4400, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3377
- schneiderActiveEnergyDivisor: { ID: 0x4401, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3378
- schneiderReactiveEnergyMultiplier: { ID: 0x4402, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3379
- schneiderReactiveEnergyDivisor: { ID: 0x4403, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3380
- schneiderApparentEnergyMultiplier: { ID: 0x4404, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3381
- schneiderApparentEnergyDivisor: { ID: 0x4405, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3382
- schneiderEnergyResetDateTime: { ID: 0x4501, type: dataType_1.default.utc, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3383
- schneiderEnergyCountersReportingPeriod: { ID: 0x4600, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3317
+ owonL1PhasePower: { ID: 0x2000, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3318
+ owonL2PhasePower: { ID: 0x2001, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3319
+ owonL3PhasePower: { ID: 0x2002, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3320
+ owonL1PhaseReactivePower: { ID: 0x2100, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3321
+ owonL2PhaseReactivePower: { ID: 0x2101, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3322
+ owonL3PhaseReactivePower: { ID: 0x2102, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3323
+ owonReactivePowerSum: { ID: 0x2103, type: dataType_1.default.int24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3324
+ owonL1PhaseVoltage: { ID: 0x3000, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3325
+ owonL2PhaseVoltage: { ID: 0x3001, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3326
+ owonL3PhaseVoltage: { ID: 0x3002, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3327
+ owonL1PhaseCurrent: { ID: 0x3100, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3328
+ owonL2PhaseCurrent: { ID: 0x3101, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3329
+ owonL3PhaseCurrent: { ID: 0x3102, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3330
+ owonCurrentSum: { ID: 0x3103, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3331
+ owonLeakageCurrent: { ID: 0x3104, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3332
+ owonL1Energy: { ID: 0x4000, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3333
+ owonL2Energy: { ID: 0x4001, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3334
+ owonL3Energy: { ID: 0x4002, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3335
+ owonL1ReactiveEnergy: { ID: 0x4100, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3336
+ owonL2ReactiveEnergy: { ID: 0x4101, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3337
+ owonL3ReactiveEnergy: { ID: 0x4102, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3338
+ owonReactiveEnergySum: { ID: 0x4103, type: dataType_1.default.uint48, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3339
+ owonL1PowerFactor: { ID: 0x4104, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3340
+ owonL2PowerFactor: { ID: 0x4105, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3341
+ owonL3PowerFactor: { ID: 0x4106, type: dataType_1.default.int8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3342
+ owonFrequency: { ID: 0x5005, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3343
+ owonReportMap: { ID: 0x1000, type: dataType_1.default.bitmap8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3344
+ owonLastHistoricalRecordTime: { ID: 0x5000, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3345
+ owonOldestHistoricalRecordTime: { ID: 0x5001, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3346
+ owonMinimumReportCycle: { ID: 0x5002, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3347
+ owonMaximumReportCycle: { ID: 0x5003, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3348
+ owonSentHistoricalRecordState: { ID: 0x5004, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3349
+ owonAccumulativeEnergyThreshold: { ID: 0x5006, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3350
+ owonReportMode: { ID: 0x5007, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3351
+ owonPercentChangeInPower: { ID: 0x5007, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC },
3352
+ schneiderActiveEnergyTotal: { ID: 0x4010, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3353
+ schneiderReactiveEnergyTotal: { ID: 0x4011, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3354
+ schneiderApparentEnergyTotal: { ID: 0x4012, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3355
+ schneiderPartialActiveEnergyTotal: { ID: 0x4014, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3356
+ schneiderPartialReactiveEnergyTotal: { ID: 0x4015, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3357
+ schneiderPartialApparentEnergyTotal: { ID: 0x4016, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3358
+ schneiderPartialActiveEnergyL1Phase: { ID: 0x4100, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3359
+ schneiderPartialReactiveEnergyL1Phase: { ID: 0x4101, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3360
+ schneiderPartialApparentEnergyL1Phase: { ID: 0x4102, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3361
+ schneiderActiveEnergyL1Phase: { ID: 0x4103, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3362
+ schneiderReactiveEnergyL1Phase: { ID: 0x4104, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3363
+ schneiderApparentEnergyL1Phase: { ID: 0x4105, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3364
+ schneiderPartialActiveEnergyL2Phase: { ID: 0x4200, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3365
+ schneiderPartialReactiveEnergyL2Phase: { ID: 0x4201, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3366
+ schneiderPartialApparentEnergyL2Phase: { ID: 0x4202, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3367
+ schneiderActiveEnergyL2Phase: { ID: 0x4203, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3368
+ schneiderReactiveEnergyL2Phase: { ID: 0x4204, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3369
+ schneiderApparentEnergyL2Phase: { ID: 0x4205, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3370
+ schneiderPartialActiveEnergyL3Phase: { ID: 0x4300, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3371
+ schneiderPartialReactiveEnergyL3Phase: { ID: 0x4301, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3372
+ schneiderPartialApparentEnergyL3Phase: { ID: 0x4302, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3373
+ schneiderActiveEnergyL3Phase: { ID: 0x4303, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3374
+ schneiderReactiveEnergyL3Phase: { ID: 0x4304, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3375
+ schneiderApparentEnergyL3Phase: { ID: 0x4305, type: dataType_1.default.int48, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3376
+ schneiderActiveEnergyMultiplier: { ID: 0x4400, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3377
+ schneiderActiveEnergyDivisor: { ID: 0x4401, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3378
+ schneiderReactiveEnergyMultiplier: { ID: 0x4402, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3379
+ schneiderReactiveEnergyDivisor: { ID: 0x4403, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3380
+ schneiderApparentEnergyMultiplier: { ID: 0x4404, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3381
+ schneiderApparentEnergyDivisor: { ID: 0x4405, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3382
+ schneiderEnergyResetDateTime: { ID: 0x4501, type: dataType_1.default.utc, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3383
+ schneiderEnergyCountersReportingPeriod: { ID: 0x4600, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3384
3384
  },
3385
3385
  commands: {
3386
3386
  getProfile: {
@@ -3768,27 +3768,27 @@ const Cluster = {
3768
3768
  rmsExtremeUnderVoltagePeriodPhC: { ID: 2581, type: dataType_1.default.uint16 },
3769
3769
  rmsVoltageSagPeriodPhC: { ID: 2582, type: dataType_1.default.uint16 },
3770
3770
  rmsVoltageSwellPeriodPhC: { ID: 2583, type: dataType_1.default.uint16 },
3771
- schneiderActivePowerDemandTotal: { ID: 0x4300, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3772
- schneiderReactivePowerDemandTotal: { ID: 0x4303, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3773
- schneiderApparentPowerDemandTotal: { ID: 0x4318, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3774
- schneiderDemandIntervalDuration: { ID: 0x4319, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3775
- schneiderDemandDateTime: { ID: 0x4320, type: dataType_1.default.utc, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3776
- schneiderActivePowerDemandPhase1: { ID: 0x4509, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3777
- schneiderReactivePowerDemandPhase1: { ID: 0x450A, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3778
- schneiderApparentPowerDemandPhase1: { ID: 0x450B, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3779
- schneiderDemandIntervalMinimalVoltageL1: { ID: 0x4510, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3780
- schneiderDemandIntervalMaximalCurrentI1: { ID: 0x4513, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3781
- schneiderActivePowerDemandPhase2: { ID: 0x4909, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3782
- schneiderReactivePowerDemandPhase2: { ID: 0x490A, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3783
- schneiderApparentPowerDemandPhase2: { ID: 0x490B, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3784
- schneiderDemandIntervalMinimalVoltageL2: { ID: 0x4910, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3785
- schneiderDemandIntervalMaximalCurrentI2: { ID: 0x4913, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3786
- schneiderActivePowerDemandPhase3: { ID: 0x4A09, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3787
- schneiderReactivePowerDemandPhase3: { ID: 0x4A0A, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3788
- schneiderApparentPowerDemandPhase3: { ID: 0x4A0B, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3789
- schneiderDemandIntervalMinimalVoltageL3: { ID: 0x4A10, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3790
- schneiderDemandIntervalMaximalCurrentI3: { ID: 0x4A13, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3791
- schneiderCurrentSensorMultiplier: { ID: 0x4E00, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3771
+ schneiderActivePowerDemandTotal: { ID: 0x4300, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3772
+ schneiderReactivePowerDemandTotal: { ID: 0x4303, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3773
+ schneiderApparentPowerDemandTotal: { ID: 0x4318, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3774
+ schneiderDemandIntervalDuration: { ID: 0x4319, type: dataType_1.default.uint24, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3775
+ schneiderDemandDateTime: { ID: 0x4320, type: dataType_1.default.utc, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3776
+ schneiderActivePowerDemandPhase1: { ID: 0x4509, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3777
+ schneiderReactivePowerDemandPhase1: { ID: 0x450A, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3778
+ schneiderApparentPowerDemandPhase1: { ID: 0x450B, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3779
+ schneiderDemandIntervalMinimalVoltageL1: { ID: 0x4510, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3780
+ schneiderDemandIntervalMaximalCurrentI1: { ID: 0x4513, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3781
+ schneiderActivePowerDemandPhase2: { ID: 0x4909, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3782
+ schneiderReactivePowerDemandPhase2: { ID: 0x490A, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3783
+ schneiderApparentPowerDemandPhase2: { ID: 0x490B, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3784
+ schneiderDemandIntervalMinimalVoltageL2: { ID: 0x4910, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3785
+ schneiderDemandIntervalMaximalCurrentI2: { ID: 0x4913, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3786
+ schneiderActivePowerDemandPhase3: { ID: 0x4A09, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3787
+ schneiderReactivePowerDemandPhase3: { ID: 0x4A0A, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3788
+ schneiderApparentPowerDemandPhase3: { ID: 0x4A0B, type: dataType_1.default.int32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3789
+ schneiderDemandIntervalMinimalVoltageL3: { ID: 0x4A10, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3790
+ schneiderDemandIntervalMaximalCurrentI3: { ID: 0x4A13, type: dataType_1.default.uint16, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3791
+ schneiderCurrentSensorMultiplier: { ID: 0x4E00, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3792
3792
  },
3793
3793
  commands: {
3794
3794
  getProfileInfo: {
@@ -3863,12 +3863,12 @@ const Cluster = {
3863
3863
  averageMacRetryPerApsMessageSent: { ID: 283, type: dataType_1.default.uint16 },
3864
3864
  lastMessageLqi: { ID: 284, type: dataType_1.default.uint8 },
3865
3865
  lastMessageRssi: { ID: 285, type: dataType_1.default.int8 },
3866
- danfossSystemStatusCode: { ID: 0x4000, type: dataType_1.default.bitmap16, manufacturerCode: manufacturerCode_1.default.DANFOSS },
3867
- danfossSystemStatusWater: { ID: 0x4200, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
3868
- danfossMultimasterRole: { ID: 0x4201, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS },
3869
- schneiderMeterStatus: { ID: 0xFF01, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3870
- schneiderDiagnosticRegister1: { ID: 0xFF02, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3871
- schneiderCommunicationQuality: { ID: 0x4000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER },
3866
+ danfossSystemStatusCode: { ID: 0x4000, type: dataType_1.default.bitmap16, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
3867
+ danfossSystemStatusWater: { ID: 0x4200, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
3868
+ danfossMultimasterRole: { ID: 0x4201, type: dataType_1.default.enum8, manufacturerCode: manufacturerCode_1.default.DANFOSS_A_S },
3869
+ schneiderMeterStatus: { ID: 0xFF01, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3870
+ schneiderDiagnosticRegister1: { ID: 0xFF02, type: dataType_1.default.uint32, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3871
+ schneiderCommunicationQuality: { ID: 0x4000, type: dataType_1.default.uint8, manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC },
3872
3872
  },
3873
3873
  commands: {},
3874
3874
  commandsResponse: {},
@@ -3991,7 +3991,7 @@ const Cluster = {
3991
3991
  },
3992
3992
  manuSpecificPhilips: {
3993
3993
  ID: 0xFC00,
3994
- manufacturerCode: manufacturerCode_1.default.PHILIPS,
3994
+ manufacturerCode: manufacturerCode_1.default.SIGNIFY_NETHERLANDS_B_V,
3995
3995
  attributes: {
3996
3996
  config: { ID: 49, type: dataType_1.default.bitmap16 },
3997
3997
  },
@@ -4012,7 +4012,7 @@ const Cluster = {
4012
4012
  },
4013
4013
  manuSpecificPhilips2: {
4014
4014
  ID: 0xFC03,
4015
- manufacturerCode: manufacturerCode_1.default.PHILIPS,
4015
+ manufacturerCode: manufacturerCode_1.default.SIGNIFY_NETHERLANDS_B_V,
4016
4016
  attributes: {
4017
4017
  state: { ID: 0x0002, type: dataType_1.default.octetStr },
4018
4018
  },
@@ -4028,7 +4028,7 @@ const Cluster = {
4028
4028
  },
4029
4029
  manuSpecificSinope: {
4030
4030
  ID: 65281,
4031
- manufacturerCode: manufacturerCode_1.default.Sinope,
4031
+ manufacturerCode: manufacturerCode_1.default.SINOPE_TECHNOLOGIES,
4032
4032
  attributes: {
4033
4033
  // attribute ID :1's readable
4034
4034
  keypadLockout: { ID: 2, type: dataType_1.default.enum8 },
@@ -4094,7 +4094,7 @@ const Cluster = {
4094
4094
  },
4095
4095
  manuSpecificUbisysDimmerSetup: {
4096
4096
  ID: 0xfc01,
4097
- manufacturerCode: manufacturerCode_1.default.Ubisys,
4097
+ manufacturerCode: manufacturerCode_1.default.UBISYS_TECHNOLOGIES_GMBH,
4098
4098
  attributes: {
4099
4099
  capabilities: { ID: 0x0000, type: dataType_1.default.bitmap8 },
4100
4100
  status: { ID: 0x0001, type: dataType_1.default.bitmap8 },
@@ -4105,7 +4105,7 @@ const Cluster = {
4105
4105
  },
4106
4106
  manuSpecificLegrandDevices: {
4107
4107
  ID: 0xfc01,
4108
- manufacturerCode: manufacturerCode_1.default.LegrandNetatmo,
4108
+ manufacturerCode: manufacturerCode_1.default.LEGRAND_GROUP,
4109
4109
  attributes: {
4110
4110
  // attributes seems to vary depending on the device. Can't be static
4111
4111
  },
@@ -4114,7 +4114,7 @@ const Cluster = {
4114
4114
  },
4115
4115
  manuSpecificLegrandDevices2: {
4116
4116
  ID: 0xfc40,
4117
- manufacturerCode: manufacturerCode_1.default.LegrandNetatmo,
4117
+ manufacturerCode: manufacturerCode_1.default.LEGRAND_GROUP,
4118
4118
  attributes: {},
4119
4119
  commands: {
4120
4120
  command0: {
@@ -4128,7 +4128,7 @@ const Cluster = {
4128
4128
  },
4129
4129
  manuSpecificLegrandDevices3: {
4130
4130
  ID: 0xfc41,
4131
- manufacturerCode: manufacturerCode_1.default.LegrandNetatmo,
4131
+ manufacturerCode: manufacturerCode_1.default.LEGRAND_GROUP,
4132
4132
  attributes: {},
4133
4133
  commands: {
4134
4134
  command0: {
@@ -4388,19 +4388,22 @@ const Cluster = {
4388
4388
  },
4389
4389
  manuSpecificLumi: {
4390
4390
  ID: 0xFCC0,
4391
- manufacturerCode: manufacturerCode_1.default.LUMI_UNITED_TECH,
4391
+ manufacturerCode: manufacturerCode_1.default.LUMI_UNITED_TECHOLOGY_LTD_SHENZHEN,
4392
4392
  attributes: {
4393
4393
  mode: { ID: 0x0009, type: dataType_1.default.uint8 },
4394
4394
  illuminance: { ID: 0x0112, type: dataType_1.default.uint32 },
4395
4395
  displayUnit: { ID: 0x0114, type: dataType_1.default.uint8 },
4396
4396
  airQuality: { ID: 0x0129, type: dataType_1.default.uint8 },
4397
+ curtainReverse: { ID: 0x0400, type: dataType_1.default.boolean },
4398
+ curtainHandOpen: { ID: 0x0401, type: dataType_1.default.boolean },
4399
+ curtainCalibrated: { ID: 0x0402, type: dataType_1.default.boolean },
4397
4400
  },
4398
4401
  commands: {},
4399
4402
  commandsResponse: {}
4400
4403
  },
4401
4404
  liXeePrivate: {
4402
4405
  ID: 0xFF66,
4403
- manufacturerCode: manufacturerCode_1.default.JENNIC,
4406
+ manufacturerCode: manufacturerCode_1.default.NXP_SEMICONDUCTORS,
4404
4407
  attributes: {
4405
4408
  currentTarif: { ID: 0x0000, type: dataType_1.default.charStr },
4406
4409
  tomorrowColor: { ID: 0x0001, type: dataType_1.default.charStr },
@@ -4489,7 +4492,7 @@ const Cluster = {
4489
4492
  },
4490
4493
  manuSpecificCentraliteHumidity: {
4491
4494
  ID: 0xFC45,
4492
- manufacturerCode: manufacturerCode_1.default.Centralite,
4495
+ manufacturerCode: manufacturerCode_1.default.CENTRALITE_SYSTEMS_INC,
4493
4496
  attributes: {
4494
4497
  measuredValue: { ID: 0, type: dataType_1.default.uint16 },
4495
4498
  },
@@ -4498,7 +4501,7 @@ const Cluster = {
4498
4501
  },
4499
4502
  manuSpecificSmartThingsArrivalSensor: {
4500
4503
  ID: 0xFC05,
4501
- manufacturerCode: manufacturerCode_1.default.SmartThings,
4504
+ manufacturerCode: manufacturerCode_1.default.SMARTTHINGS_INC,
4502
4505
  attributes: {},
4503
4506
  commands: {},
4504
4507
  commandsResponse: {
@@ -4510,7 +4513,7 @@ const Cluster = {
4510
4513
  },
4511
4514
  manuSpecificSamsungAccelerometer: {
4512
4515
  ID: 0xFC02,
4513
- manufacturerCode: manufacturerCode_1.default.SmartThings,
4516
+ manufacturerCode: manufacturerCode_1.default.SMARTTHINGS_INC,
4514
4517
  attributes: {
4515
4518
  motion_threshold_multiplier: { ID: 0, type: dataType_1.default.uint8 },
4516
4519
  motion_threshold: { ID: 2, type: dataType_1.default.uint16 },
@@ -4525,7 +4528,7 @@ const Cluster = {
4525
4528
  heimanSpecificFormaldehydeMeasurement: {
4526
4529
  // from HS2AQ-3.0海曼智能空气质量检测仪API文档-V01
4527
4530
  ID: 0x042b,
4528
- manufacturerCode: manufacturerCode_1.default.Heiman,
4531
+ manufacturerCode: manufacturerCode_1.default.HEIMAN_TECHNOLOGY_CO_LTD,
4529
4532
  attributes: {
4530
4533
  measuredValue: { ID: 0x0000, type: dataType_1.default.uint16 },
4531
4534
  measuredMinValue: { ID: 0x0001, type: dataType_1.default.uint16 },
@@ -4538,7 +4541,7 @@ const Cluster = {
4538
4541
  heimanSpecificAirQuality: {
4539
4542
  // from HS2AQ-3.0海曼智能空气质量检测仪API文档-V01
4540
4543
  ID: 0xfc81,
4541
- manufacturerCode: manufacturerCode_1.default.Heiman,
4544
+ manufacturerCode: manufacturerCode_1.default.HEIMAN_TECHNOLOGY_CO_LTD,
4542
4545
  attributes: {
4543
4546
  language: { ID: 0xf000, type: dataType_1.default.uint8 },
4544
4547
  unitOfMeasure: { ID: 0xf001, type: dataType_1.default.uint8 },
@@ -4575,7 +4578,7 @@ const Cluster = {
4575
4578
  heimanSpecificScenes: {
4576
4579
  // from HS2SS-3.0海曼智能情景开关API文档-V01
4577
4580
  ID: 0xfc80,
4578
- manufacturerCode: manufacturerCode_1.default.Heiman,
4581
+ manufacturerCode: manufacturerCode_1.default.HEIMAN_TECHNOLOGY_CO_LTD,
4579
4582
  attributes: {},
4580
4583
  commands: {
4581
4584
  cinema: {
@@ -4642,7 +4645,7 @@ const Cluster = {
4642
4645
  heimanSpecificInfraRedRemote: {
4643
4646
  // from HS2IRC-3.0海曼智能红外转发控制器API-V01文档
4644
4647
  ID: 0xfc82,
4645
- manufacturerCode: manufacturerCode_1.default.Heiman,
4648
+ manufacturerCode: manufacturerCode_1.default.HEIMAN_TECHNOLOGY_CO_LTD,
4646
4649
  attributes: {},
4647
4650
  commands: {
4648
4651
  sendKey: {
@@ -4721,7 +4724,7 @@ const Cluster = {
4721
4724
  },
4722
4725
  develcoSpecificAirQuality: {
4723
4726
  ID: 0xFC03,
4724
- manufacturerCode: manufacturerCode_1.default.Develco,
4727
+ manufacturerCode: manufacturerCode_1.default.DEVELCO,
4725
4728
  attributes: {
4726
4729
  measuredValue: { ID: 0x0000, type: dataType_1.default.uint16 },
4727
4730
  minMeasuredValue: { ID: 0x0001, type: dataType_1.default.uint16 },
@@ -4733,7 +4736,7 @@ const Cluster = {
4733
4736
  },
4734
4737
  schneiderSpecificPilotMode: {
4735
4738
  ID: 0xFF23,
4736
- manufacturerCode: manufacturerCode_1.default.SCHNEIDER,
4739
+ manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC,
4737
4740
  attributes: {
4738
4741
  pilotMode: { ID: 0x0031, type: dataType_1.default.enum8 },
4739
4742
  },
@@ -4742,7 +4745,7 @@ const Cluster = {
4742
4745
  },
4743
4746
  elkoOccupancySettingClusterServer: {
4744
4747
  ID: 0xFF19,
4745
- manufacturerCode: manufacturerCode_1.default.ELKO,
4748
+ manufacturerCode: manufacturerCode_1.default.ADEO,
4746
4749
  attributes: {
4747
4750
  AmbienceLightThreshold: { ID: 0x0000, type: dataType_1.default.uint16 },
4748
4751
  OccupancyActions: { ID: 0x0001, type: dataType_1.default.enum8 },
@@ -4754,7 +4757,7 @@ const Cluster = {
4754
4757
  },
4755
4758
  elkoSwitchConfigurationClusterServer: {
4756
4759
  ID: 0xFF17,
4757
- manufacturerCode: manufacturerCode_1.default.ELKO,
4760
+ manufacturerCode: manufacturerCode_1.default.ADEO,
4758
4761
  attributes: {
4759
4762
  SwitchIndication: { ID: 0x0000, type: dataType_1.default.enum8 },
4760
4763
  UpSceneID: { ID: 0x0010, type: dataType_1.default.uint8 },
@@ -4768,7 +4771,7 @@ const Cluster = {
4768
4771
  },
4769
4772
  manuSpecificSchneiderLightSwitchConfiguration: {
4770
4773
  ID: 0xFF17,
4771
- manufacturerCode: manufacturerCode_1.default.SCHNEIDER,
4774
+ manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC,
4772
4775
  attributes: {
4773
4776
  ledIndication: { ID: 0x0000, type: dataType_1.default.enum8 },
4774
4777
  upSceneID: { ID: 0x0010, type: dataType_1.default.uint8 },
@@ -4782,7 +4785,7 @@ const Cluster = {
4782
4785
  },
4783
4786
  manuSpecificSchneiderFanSwitchConfiguration: {
4784
4787
  ID: 0xFC04,
4785
- manufacturerCode: manufacturerCode_1.default.SCHNEIDER,
4788
+ manufacturerCode: manufacturerCode_1.default.SCHNEIDER_ELECTRIC,
4786
4789
  attributes: {
4787
4790
  ledIndication: { ID: 0x0002, type: dataType_1.default.uint8 },
4788
4791
  ledOrientation: { ID: 0x0060, type: dataType_1.default.uint8 },
@@ -4996,7 +4999,7 @@ const Cluster = {
4996
4999
  },
4997
5000
  owonClearMetering: {
4998
5001
  ID: 0xFFE0,
4999
- manufacturerCode: manufacturerCode_1.default.OWON,
5002
+ manufacturerCode: manufacturerCode_1.default.OWON_TECHNOLOGY_INC,
5000
5003
  attributes: {},
5001
5004
  commands: {
5002
5005
  owonClearMeasurementData: {
@@ -5105,7 +5108,7 @@ const Cluster = {
5105
5108
  },
5106
5109
  manuSpecificBosch: {
5107
5110
  ID: 0xe000,
5108
- manufacturerCode: manufacturerCode_1.default.Bosch,
5111
+ manufacturerCode: manufacturerCode_1.default.BOSCH_SECURITY_SYSTEMS_INC,
5109
5112
  attributes: {
5110
5113
  sensitivity: { ID: 0x4003, type: 0x21 },
5111
5114
  },
@@ -5119,7 +5122,7 @@ const Cluster = {
5119
5122
  },
5120
5123
  manuSpecificBosch3: {
5121
5124
  ID: 0xe002,
5122
- manufacturerCode: manufacturerCode_1.default.Bosch,
5125
+ manufacturerCode: manufacturerCode_1.default.BOSCH_SECURITY_SYSTEMS_INC,
5123
5126
  attributes: {
5124
5127
  humidity: { ID: 0x4000, type: 0x21 },
5125
5128
  unknown1: { ID: 0x4001, type: 0x21 },
@@ -5140,7 +5143,7 @@ const Cluster = {
5140
5143
  },
5141
5144
  manuSpecificBosch5: {
5142
5145
  ID: 0xe004,
5143
- manufacturerCode: manufacturerCode_1.default.Bosch,
5146
+ manufacturerCode: manufacturerCode_1.default.BOSCH_SECURITY_SYSTEMS_INC,
5144
5147
  attributes: {
5145
5148
  unknown_attribute: { ID: 0x4000, type: dataType_1.default.bitmap8 }, // 0,1 ??? read during pairing
5146
5149
  pre_alarm: { ID: 0x4001, type: dataType_1.default.bitmap8 }, // 0,1 on/off
@@ -5150,7 +5153,7 @@ const Cluster = {
5150
5153
  },
5151
5154
  manuSpecificBosch7: {
5152
5155
  ID: 0xe006,
5153
- manufacturerCode: manufacturerCode_1.default.Bosch,
5156
+ manufacturerCode: manufacturerCode_1.default.BOSCH_SECURITY_SYSTEMS_INC,
5154
5157
  attributes: {
5155
5158
  unknown1: { ID: 0x5003, type: 0x28 }, // perhaps signal strength? -7?
5156
5159
  unknown2: { ID: 0x5004, type: 0x20 }, // ????
@@ -5166,7 +5169,7 @@ const Cluster = {
5166
5169
  },
5167
5170
  manuSpecificBosch8: {
5168
5171
  ID: 0xe007,
5169
- manufacturerCode: manufacturerCode_1.default.Bosch,
5172
+ manufacturerCode: manufacturerCode_1.default.BOSCH_SECURITY_SYSTEMS_INC,
5170
5173
  attributes: {
5171
5174
  alarm_status: { ID: 0x5000, type: dataType_1.default.bitmap32 },
5172
5175
  },
@@ -5182,7 +5185,7 @@ const Cluster = {
5182
5185
  },
5183
5186
  manuSpecificBosch9: {
5184
5187
  ID: 0xfca1,
5185
- manufacturerCode: manufacturerCode_1.default.Bosch,
5188
+ manufacturerCode: manufacturerCode_1.default.BOSCH_SECURITY_SYSTEMS_INC,
5186
5189
  attributes: {},
5187
5190
  commands: {
5188
5191
  confirmButtonPressed: {
@@ -5202,7 +5205,7 @@ const Cluster = {
5202
5205
  },
5203
5206
  manuSpecificBosch10: {
5204
5207
  ID: 0xfca0,
5205
- manufacturerCode: manufacturerCode_1.default.Bosch,
5208
+ manufacturerCode: manufacturerCode_1.default.BOSCH_SECURITY_SYSTEMS_INC,
5206
5209
  attributes: {
5207
5210
  deviceMode: { ID: 0x0000, type: dataType_1.default.enum8 },
5208
5211
  switchType: { ID: 0x0001, type: dataType_1.default.enum8 },
@@ -5471,7 +5474,7 @@ const Cluster = {
5471
5474
  },
5472
5475
  manuSpecificNodOnPilotWire: {
5473
5476
  ID: 0xFC00,
5474
- manufacturerCode: manufacturerCode_1.default.NodOn,
5477
+ manufacturerCode: manufacturerCode_1.default.NODON,
5475
5478
  attributes: {
5476
5479
  mode: { ID: 0x0000, type: dataType_1.default.uint8 }
5477
5480
  },