zigbee-herdsman-converters 26.93.0 → 26.94.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/CHANGELOG.md CHANGED
@@ -1,5 +1,26 @@
1
1
  # Changelog
2
2
 
3
+ ## [26.94.0](https://github.com/Koenkk/zigbee-herdsman-converters/compare/v26.93.0...v26.94.0) (2026-08-10)
4
+
5
+
6
+ ### Features
7
+
8
+ * **add:** AY204T ([#12875](https://github.com/Koenkk/zigbee-herdsman-converters/issues/12875)) ([aa07ad7](https://github.com/Koenkk/zigbee-herdsman-converters/commit/aa07ad76ed0e3205aa4053604a9a3a37fa3c46f2))
9
+ * **add:** S1-TL, HS2VTD, HS2TD, HS2HT ([#12855](https://github.com/Koenkk/zigbee-herdsman-converters/issues/12855)) ([d2f92ba](https://github.com/Koenkk/zigbee-herdsman-converters/commit/d2f92ba265eee4368c919c6456f51bcc45f12845))
10
+ * **add:** Z20-IK03F ([#12864](https://github.com/Koenkk/zigbee-herdsman-converters/issues/12864)) ([09ac23f](https://github.com/Koenkk/zigbee-herdsman-converters/commit/09ac23f8b45bbb62edb2e4f8039e49852beb065d))
11
+ * Ubisys J1: Add `operational_status` converter ([#12872](https://github.com/Koenkk/zigbee-herdsman-converters/issues/12872)) ([a13da3e](https://github.com/Koenkk/zigbee-herdsman-converters/commit/a13da3eeb32381c73e21b80d058ecccb9059ddaf))
12
+
13
+
14
+ ### Bug Fixes
15
+
16
+ * AOYAN AY205Z: fix white label matching ([#12874](https://github.com/Koenkk/zigbee-herdsman-converters/issues/12874)) ([e8b7a43](https://github.com/Koenkk/zigbee-herdsman-converters/commit/e8b7a4339580c1669d19459ae7ca5403d1d002ab))
17
+ * **detect:** Detect `_TZE204_qujphad5` as Tuya TYBAC-006 ([#12869](https://github.com/Koenkk/zigbee-herdsman-converters/issues/12869)) ([fbb9a03](https://github.com/Koenkk/zigbee-herdsman-converters/commit/fbb9a030a1247e7461e143d671644956afb3c4f1))
18
+ * **ignore:** bump the minor-patch group with 2 updates ([#12866](https://github.com/Koenkk/zigbee-herdsman-converters/issues/12866)) ([20af545](https://github.com/Koenkk/zigbee-herdsman-converters/commit/20af545d917fd98d8b1fa49f3c3178fbb51f0359))
19
+ * Moes ZHT-002: improve `programming_mode` ([#12877](https://github.com/Koenkk/zigbee-herdsman-converters/issues/12877)) ([9f4b8a6](https://github.com/Koenkk/zigbee-herdsman-converters/commit/9f4b8a63881b2ebcc573fa8c87db81e4006e6a13))
20
+ * Moes ZHT-S03: remove forceTimeUpdates ([#12867](https://github.com/Koenkk/zigbee-herdsman-converters/issues/12867)) ([1f58a50](https://github.com/Koenkk/zigbee-herdsman-converters/commit/1f58a5056a82d007102956e09c54fd70b6bbc975))
21
+ * Namron 4512758: fix `away_mode` https://github.com/Koenkk/zigbee-herdsman-converters/issues/12856 ([ee68ac9](https://github.com/Koenkk/zigbee-herdsman-converters/commit/ee68ac90a7896753a15bb15f15504d033d7af86b))
22
+ * Shelly BLU TRV: implement external temperature management ([#12853](https://github.com/Koenkk/zigbee-herdsman-converters/issues/12853)) ([5076471](https://github.com/Koenkk/zigbee-herdsman-converters/commit/50764716dc12fd6858b333adb631dd1e50546c14))
23
+
3
24
  ## [26.93.0](https://github.com/Koenkk/zigbee-herdsman-converters/compare/v26.92.0...v26.93.0) (2026-08-08)
4
25
 
5
26
 
@@ -1 +1 @@
1
- {"version":3,"file":"heiman.d.ts","sourceRoot":"","sources":["../../src/devices/heiman.ts"],"names":[],"mappings":"AAmBA,OAAO,KAAK,EAAC,oBAAoB,EAAmD,MAAM,cAAc,CAAC;AA0wDzG,eAAO,MAAM,WAAW,EAAE,oBAAoB,EAi7D7C,CAAC"}
1
+ {"version":3,"file":"heiman.d.ts","sourceRoot":"","sources":["../../src/devices/heiman.ts"],"names":[],"mappings":"AAmBA,OAAO,KAAK,EAAC,oBAAoB,EAAmD,MAAM,cAAc,CAAC;AA0wDzG,eAAO,MAAM,WAAW,EAAE,oBAAoB,EAqmE7C,CAAC"}
@@ -2888,6 +2888,64 @@ exports.definitions = [
2888
2888
  ],
2889
2889
  ota: true,
2890
2890
  },
2891
+ {
2892
+ zigbeeModel: ["S1-TL"],
2893
+ model: "S1-TL",
2894
+ vendor: "Heiman",
2895
+ description: "Smart smoke alarm",
2896
+ fromZigbee: [fzLocal.heimanClusterSpecialfz],
2897
+ toZigbee: [tz.warning],
2898
+ configure: async (device, coordinatorEndpoint) => {
2899
+ const endpoint = device.getEndpoint(1);
2900
+ const endpoint2 = device.getEndpoint(2);
2901
+ await reporting.bind(endpoint, coordinatorEndpoint, ["genPowerCfg", "heimanClusterSpecial"]);
2902
+ await reporting.batteryPercentageRemaining(endpoint);
2903
+ await endpoint.read("ssIasZone", ["zoneStatus", "zoneState", "iasCieAddr", "zoneId"]);
2904
+ await endpoint.read("msTemperatureMeasurement", ["measuredValue"]);
2905
+ await endpoint.read("heimanClusterSpecial", [
2906
+ "sensorFaultState",
2907
+ "deviceMuteControl",
2908
+ "deviceMuteState",
2909
+ "indicatorLightLevelControlOf1",
2910
+ "interconnectable",
2911
+ "smokeConcentrationLevel",
2912
+ "smokeChamberContaminationLevel",
2913
+ "smokeConcentationUnit",
2914
+ "rebootedCount",
2915
+ "rejoinedCount",
2916
+ "reportedPackages",
2917
+ "temperatureOffset",
2918
+ ], {
2919
+ manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.HEIMAN_TECHNOLOGY_CO_LTD,
2920
+ });
2921
+ await endpoint2.read("msRelativeHumidity", ["measuredValue"]);
2922
+ },
2923
+ exposes: [],
2924
+ extend: [
2925
+ m.battery(),
2926
+ m.identify(),
2927
+ m.temperature({ reporting: { min: 10, max: 3600, change: 200 } }),
2928
+ m.humidity({ reporting: { min: 10, max: 3600, change: 500 } }),
2929
+ m.iasZoneAlarm({ zoneType: "smoke", zoneAttributes: ["alarm_1", "battery_low", "test"] }),
2930
+ heimanExtend.heimanClusterSpecial(),
2931
+ heimanExtend.heimanClusterSensorFaultState(),
2932
+ heimanExtend.heimanClusterDeviceMuteState(),
2933
+ heimanExtend.iasZoneInitiateTestMode(),
2934
+ heimanExtend.heimanClusterSensorMutable(),
2935
+ heimanExtend.heimanClusterIndicatorLight(),
2936
+ heimanExtend.heimanClusterSensorInterconnectable(),
2937
+ heimanExtend.smokeConcentrationLevel(),
2938
+ heimanExtend.smokeConcentationUnit(),
2939
+ heimanExtend.smokeChamberContaminationLevel(),
2940
+ heimanExtend.linkAvailable(),
2941
+ heimanExtend.sirenForAutomationOnly(),
2942
+ heimanExtend.temperatureOffset(),
2943
+ heimanExtend.reportedPackages(),
2944
+ heimanExtend.rejoinedCount(),
2945
+ heimanExtend.rebootedCount(),
2946
+ ],
2947
+ ota: true,
2948
+ },
2891
2949
  {
2892
2950
  zigbeeModel: ["HM-722ESY-E-PLUS"],
2893
2951
  model: "HM-722ESY-E Plus",
@@ -3436,5 +3494,111 @@ exports.definitions = [
3436
3494
  ],
3437
3495
  ota: true,
3438
3496
  },
3497
+ {
3498
+ zigbeeModel: ["HS2VTD"],
3499
+ model: "HS2VTD",
3500
+ vendor: "Heiman",
3501
+ description: "Smart 4 in 1 door sensor",
3502
+ fromZigbee: [fzLocal.heimanClusterSpecialfz],
3503
+ toZigbee: [tz.warning],
3504
+ configure: async (device, coordinatorEndpoint) => {
3505
+ const endpoint = device.getEndpoint(1);
3506
+ const endpoint2 = device.getEndpoint(2);
3507
+ await reporting.bind(endpoint, coordinatorEndpoint, ["genPowerCfg", "heimanClusterSpecial"]);
3508
+ await reporting.batteryPercentageRemaining(endpoint);
3509
+ await endpoint.read("ssIasZone", ["zoneStatus", "zoneState", "iasCieAddr", "zoneId"]);
3510
+ await endpoint.read("msTemperatureMeasurement", ["measuredValue"]);
3511
+ await endpoint.read("heimanClusterSpecial", ["indicatorLightLevelControlOf1", "rebootedCount", "rejoinedCount", "reportedPackages", "temperatureOffset", "humidityOffset"], {
3512
+ manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.HEIMAN_TECHNOLOGY_CO_LTD,
3513
+ });
3514
+ await endpoint2.read("msRelativeHumidity", ["measuredValue"]);
3515
+ },
3516
+ exposes: [],
3517
+ extend: [
3518
+ m.battery(),
3519
+ m.identify(),
3520
+ m.temperature({ reporting: { min: 10, max: 3600, change: 200 } }),
3521
+ m.humidity({ reporting: { min: 10, max: 3600, change: 500 } }),
3522
+ m.iasZoneAlarm({ zoneType: "contact", zoneAttributes: ["alarm_1", "alarm_2", "battery_low"] }),
3523
+ heimanExtend.heimanClusterSpecial(),
3524
+ heimanExtend.heimanClusterIndicatorLight(),
3525
+ heimanExtend.temperatureOffset(),
3526
+ heimanExtend.humidityOffset(),
3527
+ heimanExtend.reportedPackages(),
3528
+ heimanExtend.rejoinedCount(),
3529
+ heimanExtend.rebootedCount(),
3530
+ ],
3531
+ ota: true,
3532
+ },
3533
+ {
3534
+ zigbeeModel: ["HS2TD"],
3535
+ model: "HS2TD",
3536
+ vendor: "Heiman",
3537
+ description: "Smart 3 in 1 door sensor",
3538
+ fromZigbee: [fzLocal.heimanClusterSpecialfz],
3539
+ toZigbee: [tz.warning],
3540
+ configure: async (device, coordinatorEndpoint) => {
3541
+ const endpoint = device.getEndpoint(1);
3542
+ const endpoint2 = device.getEndpoint(2);
3543
+ await reporting.bind(endpoint, coordinatorEndpoint, ["genPowerCfg", "heimanClusterSpecial"]);
3544
+ await reporting.batteryPercentageRemaining(endpoint);
3545
+ await endpoint.read("ssIasZone", ["zoneStatus", "zoneState", "iasCieAddr", "zoneId"]);
3546
+ await endpoint.read("msTemperatureMeasurement", ["measuredValue"]);
3547
+ await endpoint.read("heimanClusterSpecial", ["indicatorLightLevelControlOf1", "rebootedCount", "rejoinedCount", "reportedPackages", "temperatureOffset", "humidityOffset"], {
3548
+ manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.HEIMAN_TECHNOLOGY_CO_LTD,
3549
+ });
3550
+ await endpoint2.read("msRelativeHumidity", ["measuredValue"]);
3551
+ },
3552
+ exposes: [],
3553
+ extend: [
3554
+ m.battery(),
3555
+ m.identify(),
3556
+ m.temperature({ reporting: { min: 10, max: 3600, change: 200 } }),
3557
+ m.humidity({ reporting: { min: 10, max: 3600, change: 500 } }),
3558
+ m.iasZoneAlarm({ zoneType: "contact", zoneAttributes: ["alarm_1", "battery_low"] }),
3559
+ heimanExtend.heimanClusterSpecial(),
3560
+ heimanExtend.heimanClusterIndicatorLight(),
3561
+ heimanExtend.temperatureOffset(),
3562
+ heimanExtend.humidityOffset(),
3563
+ heimanExtend.reportedPackages(),
3564
+ heimanExtend.rejoinedCount(),
3565
+ heimanExtend.rebootedCount(),
3566
+ ],
3567
+ ota: true,
3568
+ },
3569
+ {
3570
+ zigbeeModel: ["HS2HT"],
3571
+ model: "HS2HT",
3572
+ vendor: "Heiman",
3573
+ description: "Smart temperature & humidity sensor",
3574
+ fromZigbee: [fzLocal.heimanClusterSpecialfz],
3575
+ toZigbee: [tz.warning],
3576
+ configure: async (device, coordinatorEndpoint) => {
3577
+ const endpoint = device.getEndpoint(1);
3578
+ const endpoint2 = device.getEndpoint(2);
3579
+ await reporting.bind(endpoint, coordinatorEndpoint, ["genPowerCfg", "heimanClusterSpecial"]);
3580
+ await reporting.batteryPercentageRemaining(endpoint);
3581
+ await endpoint.read("msTemperatureMeasurement", ["measuredValue"]);
3582
+ await endpoint.read("heimanClusterSpecial", ["indicatorLightLevelControlOf1", "rebootedCount", "rejoinedCount", "reportedPackages", "temperatureOffset", "humidityOffset"], {
3583
+ manufacturerCode: zigbee_herdsman_1.Zcl.ManufacturerCode.HEIMAN_TECHNOLOGY_CO_LTD,
3584
+ });
3585
+ await endpoint2.read("msRelativeHumidity", ["measuredValue"]);
3586
+ },
3587
+ exposes: [],
3588
+ extend: [
3589
+ m.battery(),
3590
+ m.identify(),
3591
+ m.temperature({ reporting: { min: 10, max: 3600, change: 200 } }),
3592
+ m.humidity({ reporting: { min: 10, max: 3600, change: 500 } }),
3593
+ heimanExtend.heimanClusterSpecial(),
3594
+ heimanExtend.heimanClusterIndicatorLight(),
3595
+ heimanExtend.temperatureOffset(),
3596
+ heimanExtend.humidityOffset(),
3597
+ heimanExtend.reportedPackages(),
3598
+ heimanExtend.rejoinedCount(),
3599
+ heimanExtend.rebootedCount(),
3600
+ ],
3601
+ ota: true,
3602
+ },
3439
3603
  ];
3440
3604
  //# sourceMappingURL=heiman.js.map