zigbee-herdsman-converters 25.76.0 → 25.78.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (62) hide show
  1. package/CHANGELOG.md +42 -0
  2. package/dist/converters/actions.d.ts.map +1 -1
  3. package/dist/converters/actions.js +7 -3
  4. package/dist/converters/actions.js.map +1 -1
  5. package/dist/devices/engo.d.ts.map +1 -1
  6. package/dist/devices/engo.js +118 -0
  7. package/dist/devices/engo.js.map +1 -1
  8. package/dist/devices/eurotronic.js +2 -2
  9. package/dist/devices/eurotronic.js.map +1 -1
  10. package/dist/devices/hej.d.ts.map +1 -1
  11. package/dist/devices/hej.js +21 -0
  12. package/dist/devices/hej.js.map +1 -1
  13. package/dist/devices/hive.d.ts.map +1 -1
  14. package/dist/devices/hive.js +7 -0
  15. package/dist/devices/hive.js.map +1 -1
  16. package/dist/devices/lixee.d.ts.map +1 -1
  17. package/dist/devices/lixee.js +86 -25
  18. package/dist/devices/lixee.js.map +1 -1
  19. package/dist/devices/lumi.d.ts.map +1 -1
  20. package/dist/devices/lumi.js +63 -20
  21. package/dist/devices/lumi.js.map +1 -1
  22. package/dist/devices/lytko.d.ts.map +1 -1
  23. package/dist/devices/lytko.js +854 -0
  24. package/dist/devices/lytko.js.map +1 -1
  25. package/dist/devices/moes.d.ts.map +1 -1
  26. package/dist/devices/moes.js +21 -0
  27. package/dist/devices/moes.js.map +1 -1
  28. package/dist/devices/multir.js +2 -2
  29. package/dist/devices/multir.js.map +1 -1
  30. package/dist/devices/namron.d.ts.map +1 -1
  31. package/dist/devices/namron.js +2 -1
  32. package/dist/devices/namron.js.map +1 -1
  33. package/dist/devices/philips.d.ts.map +1 -1
  34. package/dist/devices/philips.js +14 -0
  35. package/dist/devices/philips.js.map +1 -1
  36. package/dist/devices/profalux.d.ts.map +1 -1
  37. package/dist/devices/profalux.js +2 -1
  38. package/dist/devices/profalux.js.map +1 -1
  39. package/dist/devices/slacky_diy.js +1 -1
  40. package/dist/devices/slacky_diy.js.map +1 -1
  41. package/dist/devices/sonoff.d.ts.map +1 -1
  42. package/dist/devices/sonoff.js +4 -1
  43. package/dist/devices/sonoff.js.map +1 -1
  44. package/dist/devices/sunricher.d.ts.map +1 -1
  45. package/dist/devices/sunricher.js +13 -0
  46. package/dist/devices/sunricher.js.map +1 -1
  47. package/dist/devices/third_reality.d.ts.map +1 -1
  48. package/dist/devices/third_reality.js +111 -3
  49. package/dist/devices/third_reality.js.map +1 -1
  50. package/dist/devices/tuya.d.ts.map +1 -1
  51. package/dist/devices/tuya.js +10 -4
  52. package/dist/devices/tuya.js.map +1 -1
  53. package/dist/lib/lumi.d.ts +6 -0
  54. package/dist/lib/lumi.d.ts.map +1 -1
  55. package/dist/lib/lumi.js +77 -0
  56. package/dist/lib/lumi.js.map +1 -1
  57. package/dist/lib/modernExtend.d.ts +2 -1
  58. package/dist/lib/modernExtend.d.ts.map +1 -1
  59. package/dist/lib/modernExtend.js +39 -9
  60. package/dist/lib/modernExtend.js.map +1 -1
  61. package/dist/models-index.json +1 -1
  62. package/package.json +1 -1
@@ -39,6 +39,7 @@ const fz = __importStar(require("../converters/fromZigbee"));
39
39
  const tz = __importStar(require("../converters/toZigbee"));
40
40
  const constants = __importStar(require("../lib/constants"));
41
41
  const exposes = __importStar(require("../lib/exposes"));
42
+ const modernExtend_1 = require("../lib/modernExtend");
42
43
  const reporting = __importStar(require("../lib/reporting"));
43
44
  const utils_1 = require("../lib/utils");
44
45
  const e = exposes.presets;
@@ -782,5 +783,858 @@ exports.definitions = [
782
783
  await endpoint4.read("hvacThermostat", ["localTemp", "occupiedHeatingSetpoint", "systemMode", "runningMode"]);
783
784
  },
784
785
  },
786
+ {
787
+ zigbeeModel: ["L101Ze-SLN"],
788
+ model: "L101Ze-SLN",
789
+ vendor: "LYTKO",
790
+ description: "Lytko single chanel thermostat without display",
791
+ ota: true,
792
+ meta: { multiEndpoint: true },
793
+ extend: [
794
+ (0, modernExtend_1.deviceAddCustomCluster)("hvacThermostat", {
795
+ ID: zigbee_herdsman_1.Zcl.Clusters.hvacThermostat.ID,
796
+ attributes: {
797
+ occupiedSetback: {
798
+ ID: 0x0034,
799
+ type: zigbee_herdsman_1.Zcl.DataType.UINT8,
800
+ },
801
+ lytkoSensor: {
802
+ ID: 0xff00,
803
+ type: zigbee_herdsman_1.Zcl.DataType.ENUM8,
804
+ manufacturerCode: manufacturerOptions.manufacturerCode,
805
+ },
806
+ },
807
+ commands: {},
808
+ commandsResponse: {},
809
+ }),
810
+ (0, modernExtend_1.deviceEndpoints)({
811
+ endpoints: { 1: 1, 3: 3 },
812
+ }),
813
+ (0, modernExtend_1.thermostat)({
814
+ setpoints: {
815
+ values: {
816
+ occupiedHeatingSetpoint: { min: 5, max: 40, step: 0.5 },
817
+ },
818
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
819
+ },
820
+ systemMode: {
821
+ values: ["off", "heat"],
822
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
823
+ },
824
+ runningMode: {
825
+ values: ["off", "heat"],
826
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
827
+ },
828
+ localTemperatureCalibration: {
829
+ values: { min: -2.5, max: 2.5, step: 0.1 },
830
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
831
+ },
832
+ localTemperature: {
833
+ configure: { reporting: { min: "1_MINUTE", max: "2_MINUTES", change: 50 } },
834
+ },
835
+ endpoint: "3",
836
+ }),
837
+ (0, modernExtend_1.identify)(),
838
+ (0, modernExtend_1.numeric)({
839
+ name: "occupied_setback",
840
+ description: "Hysteresis",
841
+ unit: "°C",
842
+ cluster: "hvacThermostat",
843
+ attribute: "occupiedSetback",
844
+ scale: 10,
845
+ valueMin: 1.0,
846
+ valueMax: 2.5,
847
+ valueStep: 0.1,
848
+ precision: 1,
849
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
850
+ endpointNames: ["3"],
851
+ entityCategory: "config",
852
+ }),
853
+ (0, modernExtend_1.enumLookup)({
854
+ name: "remote_sensing",
855
+ label: "Remote sensing",
856
+ description: "",
857
+ lookup: { internally: 0, remotely: 1 },
858
+ cluster: "hvacThermostat",
859
+ attribute: "remoteSensing",
860
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
861
+ endpointName: "3",
862
+ entityCategory: "config",
863
+ }),
864
+ (0, modernExtend_1.enumLookup)({
865
+ name: "sensor_type",
866
+ label: "Sensor",
867
+ description: "Sensor type",
868
+ lookup: { "3.3K": 0, "5.0K": 1, "6.8K": 2, "10.0K": 3, "12.0K": 4, "14.8K": 5, "15.0K": 6, "20.0K": 7, "33.0K": 8, "47.0K": 9 },
869
+ cluster: "hvacThermostat",
870
+ attribute: "lytkoSensor",
871
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
872
+ endpointName: "3",
873
+ zigbeeCommandOptions: manufacturerOptions,
874
+ entityCategory: "config",
875
+ }),
876
+ ],
877
+ },
878
+ {
879
+ zigbeeModel: ["L101Ze-SLM"],
880
+ model: "L101Ze-SLM",
881
+ vendor: "LYTKO",
882
+ description: "Lytko single chanel thermostat without display",
883
+ ota: true,
884
+ meta: { multiEndpoint: true },
885
+ extend: [
886
+ (0, modernExtend_1.deviceAddCustomCluster)("hvacThermostat", {
887
+ ID: zigbee_herdsman_1.Zcl.Clusters.hvacThermostat.ID,
888
+ attributes: {
889
+ occupiedSetback: {
890
+ ID: 0x0034,
891
+ type: zigbee_herdsman_1.Zcl.DataType.UINT8,
892
+ },
893
+ lytkoSensor: {
894
+ ID: 0xff00,
895
+ type: zigbee_herdsman_1.Zcl.DataType.ENUM8,
896
+ manufacturerCode: manufacturerOptions.manufacturerCode,
897
+ },
898
+ },
899
+ commands: {},
900
+ commandsResponse: {},
901
+ }),
902
+ (0, modernExtend_1.deviceEndpoints)({
903
+ endpoints: { 1: 1, 3: 3 },
904
+ }),
905
+ (0, modernExtend_1.thermostat)({
906
+ setpoints: {
907
+ values: {
908
+ occupiedHeatingSetpoint: { min: 5, max: 40, step: 0.5 },
909
+ },
910
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
911
+ },
912
+ systemMode: {
913
+ values: ["off", "heat"],
914
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
915
+ },
916
+ runningMode: {
917
+ values: ["off", "heat"],
918
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
919
+ },
920
+ localTemperatureCalibration: {
921
+ values: { min: -2.5, max: 2.5, step: 0.1 },
922
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
923
+ },
924
+ localTemperature: {
925
+ configure: { reporting: { min: "1_MINUTE", max: "2_MINUTES", change: 50 } },
926
+ },
927
+ endpoint: "3",
928
+ }),
929
+ (0, modernExtend_1.identify)(),
930
+ (0, modernExtend_1.numeric)({
931
+ name: "occupied_setback",
932
+ description: "Hysteresis",
933
+ unit: "°C",
934
+ cluster: "hvacThermostat",
935
+ attribute: "occupiedSetback",
936
+ scale: 10,
937
+ valueMin: 1.0,
938
+ valueMax: 2.5,
939
+ valueStep: 0.1,
940
+ precision: 1,
941
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
942
+ endpointNames: ["3"],
943
+ entityCategory: "config",
944
+ }),
945
+ (0, modernExtend_1.enumLookup)({
946
+ name: "remote_sensing",
947
+ label: "Remote sensing",
948
+ description: "",
949
+ lookup: { internally: 0, remotely: 1 },
950
+ cluster: "hvacThermostat",
951
+ attribute: "remoteSensing",
952
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
953
+ endpointName: "3",
954
+ entityCategory: "config",
955
+ }),
956
+ (0, modernExtend_1.enumLookup)({
957
+ name: "sensor_type",
958
+ label: "Sensor",
959
+ description: "Sensor type",
960
+ lookup: { "3.3K": 0, "5.0K": 1, "6.8K": 2, "10.0K": 3, "12.0K": 4, "14.8K": 5, "15.0K": 6, "20.0K": 7, "33.0K": 8, "47.0K": 9 },
961
+ cluster: "hvacThermostat",
962
+ attribute: "lytkoSensor",
963
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
964
+ endpointName: "3",
965
+ zigbeeCommandOptions: manufacturerOptions,
966
+ entityCategory: "config",
967
+ }),
968
+ (0, modernExtend_1.numeric)({
969
+ name: "power_apparent",
970
+ label: "Power Apparent",
971
+ description: "Power apparent",
972
+ unit: "VA",
973
+ cluster: "haElectricalMeasurement",
974
+ attribute: "apparentPower",
975
+ precision: 1,
976
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
977
+ access: "STATE_GET",
978
+ endpointNames: ["3"],
979
+ }),
980
+ (0, modernExtend_1.electricityMeter)({
981
+ type: "electricity",
982
+ cluster: "both",
983
+ voltage: false,
984
+ power: false,
985
+ endpointNames: ["3"],
986
+ configureReporting: true,
987
+ }),
988
+ ],
989
+ },
990
+ {
991
+ zigbeeModel: ["L101Ze-SBN"],
992
+ model: "L101Ze-SBN",
993
+ vendor: "LYTKO",
994
+ description: "Lytko single chanel thermostat with big display",
995
+ ota: true,
996
+ meta: { multiEndpoint: true },
997
+ extend: [
998
+ (0, modernExtend_1.deviceAddCustomCluster)("hvacThermostat", {
999
+ ID: zigbee_herdsman_1.Zcl.Clusters.hvacThermostat.ID,
1000
+ attributes: {
1001
+ occupiedSetback: {
1002
+ ID: 0x0034,
1003
+ type: zigbee_herdsman_1.Zcl.DataType.UINT8,
1004
+ },
1005
+ lytkoSensor: {
1006
+ ID: 0xff00,
1007
+ type: zigbee_herdsman_1.Zcl.DataType.ENUM8,
1008
+ manufacturerCode: manufacturerOptions.manufacturerCode,
1009
+ },
1010
+ lytkoTargetFirst: {
1011
+ ID: 0xff01,
1012
+ type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN,
1013
+ manufacturerCode: manufacturerOptions.manufacturerCode,
1014
+ },
1015
+ },
1016
+ commands: {},
1017
+ commandsResponse: {},
1018
+ }),
1019
+ (0, modernExtend_1.deviceAddCustomCluster)("hvacUserInterfaceCfg", {
1020
+ ID: zigbee_herdsman_1.Zcl.Clusters.hvacUserInterfaceCfg.ID,
1021
+ attributes: {
1022
+ brignessActive: {
1023
+ ID: 0xff00,
1024
+ type: zigbee_herdsman_1.Zcl.DataType.ENUM8,
1025
+ manufacturerCode: manufacturerOptions.manufacturerCode,
1026
+ },
1027
+ brignessStandby: {
1028
+ ID: 0xff01,
1029
+ type: zigbee_herdsman_1.Zcl.DataType.ENUM8,
1030
+ manufacturerCode: manufacturerOptions.manufacturerCode,
1031
+ },
1032
+ },
1033
+ commands: {},
1034
+ commandsResponse: {},
1035
+ }),
1036
+ (0, modernExtend_1.deviceEndpoints)({
1037
+ endpoints: { 1: 1, 3: 3 },
1038
+ }),
1039
+ (0, modernExtend_1.thermostat)({
1040
+ setpoints: {
1041
+ values: {
1042
+ occupiedHeatingSetpoint: { min: 5, max: 40, step: 0.5 },
1043
+ },
1044
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1045
+ },
1046
+ systemMode: {
1047
+ values: ["off", "heat"],
1048
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1049
+ },
1050
+ runningMode: {
1051
+ values: ["off", "heat"],
1052
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1053
+ },
1054
+ localTemperatureCalibration: {
1055
+ values: { min: -2.5, max: 2.5, step: 0.1 },
1056
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1057
+ },
1058
+ localTemperature: {
1059
+ configure: { reporting: { min: "1_MINUTE", max: "2_MINUTES", change: 50 } },
1060
+ },
1061
+ endpoint: "3",
1062
+ }),
1063
+ (0, modernExtend_1.identify)(),
1064
+ (0, modernExtend_1.binary)({
1065
+ name: "child_lock",
1066
+ cluster: "hvacUserInterfaceCfg",
1067
+ attribute: "keypadLockout",
1068
+ description: "Enables/disables physical input on the device",
1069
+ access: "ALL",
1070
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1071
+ valueOn: ["lock", 1],
1072
+ valueOff: ["unlock", 0],
1073
+ entityCategory: "config",
1074
+ }),
1075
+ (0, modernExtend_1.numeric)({
1076
+ name: "brigness_Active",
1077
+ label: "Brigness Active",
1078
+ description: "Display brightness in work mode",
1079
+ unit: "%",
1080
+ cluster: "hvacUserInterfaceCfg",
1081
+ attribute: "brignessActive",
1082
+ valueMin: 0,
1083
+ valueMax: 100,
1084
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1085
+ access: "ALL",
1086
+ entityCategory: "config",
1087
+ }),
1088
+ (0, modernExtend_1.numeric)({
1089
+ name: "brigness_Standby",
1090
+ label: "Brigness Standby",
1091
+ description: "Display brightness in standby mode",
1092
+ unit: "%",
1093
+ cluster: "hvacUserInterfaceCfg",
1094
+ attribute: "brignessStandby",
1095
+ valueMin: 0,
1096
+ valueMax: 100,
1097
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1098
+ access: "ALL",
1099
+ entityCategory: "config",
1100
+ }),
1101
+ (0, modernExtend_1.numeric)({
1102
+ name: "occupied_setback",
1103
+ description: "Hysteresis",
1104
+ unit: "°C",
1105
+ cluster: "hvacThermostat",
1106
+ attribute: "occupiedSetback",
1107
+ scale: 10,
1108
+ valueMin: 1.0,
1109
+ valueMax: 2.5,
1110
+ valueStep: 0.1,
1111
+ precision: 1,
1112
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1113
+ endpointNames: ["3"],
1114
+ entityCategory: "config",
1115
+ }),
1116
+ (0, modernExtend_1.enumLookup)({
1117
+ name: "sensor_type",
1118
+ label: "Sensor",
1119
+ description: "Sensor type",
1120
+ lookup: { "3.3K": 0, "5.0K": 1, "6.8K": 2, "10.0K": 3, "12.0K": 4, "14.8K": 5, "15.0K": 6, "20.0K": 7, "33.0K": 8, "47.0K": 9 },
1121
+ cluster: "hvacThermostat",
1122
+ attribute: "lytkoSensor",
1123
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1124
+ endpointName: "3",
1125
+ zigbeeCommandOptions: manufacturerOptions,
1126
+ entityCategory: "config",
1127
+ }),
1128
+ (0, modernExtend_1.enumLookup)({
1129
+ name: "target_first",
1130
+ label: "First temperature",
1131
+ description: "Display target/current temperature first",
1132
+ lookup: { Target: 0, Current: 1 },
1133
+ cluster: "hvacThermostat",
1134
+ attribute: "lytkoTargetFirst",
1135
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1136
+ endpointName: "3",
1137
+ zigbeeCommandOptions: manufacturerOptions,
1138
+ entityCategory: "config",
1139
+ }),
1140
+ ],
1141
+ },
1142
+ {
1143
+ zigbeeModel: ["L101Ze-DLN"],
1144
+ model: "L101Ze-DLN",
1145
+ vendor: "LYTKO",
1146
+ description: "Lytko dual chanel thermostat without display",
1147
+ ota: true,
1148
+ meta: { multiEndpoint: true },
1149
+ extend: [
1150
+ (0, modernExtend_1.deviceAddCustomCluster)("hvacThermostat", {
1151
+ ID: zigbee_herdsman_1.Zcl.Clusters.hvacThermostat.ID,
1152
+ attributes: {
1153
+ occupiedSetback: {
1154
+ ID: 0x0034,
1155
+ type: zigbee_herdsman_1.Zcl.DataType.UINT8,
1156
+ },
1157
+ lytkoSensor: {
1158
+ ID: 0xff00,
1159
+ type: zigbee_herdsman_1.Zcl.DataType.ENUM8,
1160
+ manufacturerCode: manufacturerOptions.manufacturerCode,
1161
+ },
1162
+ },
1163
+ commands: {},
1164
+ commandsResponse: {},
1165
+ }),
1166
+ (0, modernExtend_1.deviceEndpoints)({
1167
+ endpoints: { 1: 1, 3: 3, 4: 4 },
1168
+ }),
1169
+ (0, modernExtend_1.thermostat)({
1170
+ setpoints: {
1171
+ values: {
1172
+ occupiedHeatingSetpoint: { min: 5, max: 40, step: 0.5 },
1173
+ },
1174
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1175
+ },
1176
+ systemMode: {
1177
+ values: ["off", "heat"],
1178
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1179
+ },
1180
+ runningMode: {
1181
+ values: ["off", "heat"],
1182
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1183
+ },
1184
+ localTemperatureCalibration: {
1185
+ values: { min: -2.5, max: 2.5, step: 0.1 },
1186
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1187
+ },
1188
+ localTemperature: {
1189
+ configure: { reporting: { min: "1_MINUTE", max: "2_MINUTES", change: 50 } },
1190
+ },
1191
+ endpoint: "3",
1192
+ }),
1193
+ (0, modernExtend_1.thermostat)({
1194
+ setpoints: {
1195
+ values: {
1196
+ occupiedHeatingSetpoint: { min: 5, max: 40, step: 0.5 },
1197
+ },
1198
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1199
+ },
1200
+ systemMode: {
1201
+ values: ["off", "heat"],
1202
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1203
+ },
1204
+ runningMode: {
1205
+ values: ["off", "heat"],
1206
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1207
+ },
1208
+ localTemperatureCalibration: {
1209
+ values: { min: -2.5, max: 2.5, step: 0.1 },
1210
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1211
+ },
1212
+ localTemperature: {
1213
+ configure: { reporting: { min: "1_MINUTE", max: "2_MINUTES", change: 50 } },
1214
+ },
1215
+ endpoint: "4",
1216
+ }),
1217
+ (0, modernExtend_1.identify)(),
1218
+ (0, modernExtend_1.numeric)({
1219
+ name: "occupied_setback",
1220
+ description: "Hysteresis",
1221
+ unit: "°C",
1222
+ cluster: "hvacThermostat",
1223
+ attribute: "occupiedSetback",
1224
+ scale: 10,
1225
+ valueMin: 1.0,
1226
+ valueMax: 2.5,
1227
+ valueStep: 0.1,
1228
+ precision: 1,
1229
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1230
+ endpointNames: ["3", "4"],
1231
+ entityCategory: "config",
1232
+ }),
1233
+ (0, modernExtend_1.enumLookup)({
1234
+ name: "remote_sensing",
1235
+ label: "Remote sensing",
1236
+ description: "",
1237
+ lookup: { internally: 0, remotely: 1 },
1238
+ cluster: "hvacThermostat",
1239
+ attribute: "remoteSensing",
1240
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1241
+ endpointName: "3",
1242
+ entityCategory: "config",
1243
+ }),
1244
+ (0, modernExtend_1.enumLookup)({
1245
+ name: "remote_sensing",
1246
+ label: "Remote sensing",
1247
+ description: "",
1248
+ lookup: { internally: 0, remotely: 1 },
1249
+ cluster: "hvacThermostat",
1250
+ attribute: "remoteSensing",
1251
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1252
+ endpointName: "4",
1253
+ entityCategory: "config",
1254
+ }),
1255
+ (0, modernExtend_1.enumLookup)({
1256
+ name: "sensor_type",
1257
+ label: "Sensor",
1258
+ description: "Sensor type",
1259
+ lookup: { "3.3K": 0, "5.0K": 1, "6.8K": 2, "10.0K": 3, "12.0K": 4, "14.8K": 5, "15.0K": 6, "20.0K": 7, "33.0K": 8, "47.0K": 9 },
1260
+ cluster: "hvacThermostat",
1261
+ attribute: "lytkoSensor",
1262
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1263
+ endpointName: "3",
1264
+ zigbeeCommandOptions: manufacturerOptions,
1265
+ entityCategory: "config",
1266
+ }),
1267
+ (0, modernExtend_1.enumLookup)({
1268
+ name: "sensor_type",
1269
+ label: "Sensor",
1270
+ description: "Sensor type",
1271
+ lookup: { "3.3K": 0, "5.0K": 1, "6.8K": 2, "10.0K": 3, "12.0K": 4, "14.8K": 5, "15.0K": 6, "20.0K": 7, "33.0K": 8, "47.0K": 9 },
1272
+ cluster: "hvacThermostat",
1273
+ attribute: "lytkoSensor",
1274
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1275
+ endpointName: "4",
1276
+ zigbeeCommandOptions: manufacturerOptions,
1277
+ entityCategory: "config",
1278
+ }),
1279
+ ],
1280
+ },
1281
+ {
1282
+ zigbeeModel: ["L101Ze-DLM"],
1283
+ model: "L101Ze-DLM",
1284
+ vendor: "LYTKO",
1285
+ description: "Lytko dual chanel thermostat without display",
1286
+ ota: true,
1287
+ meta: { multiEndpoint: true },
1288
+ extend: [
1289
+ (0, modernExtend_1.deviceAddCustomCluster)("hvacThermostat", {
1290
+ ID: zigbee_herdsman_1.Zcl.Clusters.hvacThermostat.ID,
1291
+ attributes: {
1292
+ occupiedSetback: {
1293
+ ID: 0x0034,
1294
+ type: zigbee_herdsman_1.Zcl.DataType.UINT8,
1295
+ },
1296
+ lytkoSensor: {
1297
+ ID: 0xff00,
1298
+ type: zigbee_herdsman_1.Zcl.DataType.ENUM8,
1299
+ manufacturerCode: manufacturerOptions.manufacturerCode,
1300
+ },
1301
+ },
1302
+ commands: {},
1303
+ commandsResponse: {},
1304
+ }),
1305
+ (0, modernExtend_1.deviceEndpoints)({
1306
+ endpoints: { 1: 1, 3: 3, 4: 4 },
1307
+ }),
1308
+ (0, modernExtend_1.thermostat)({
1309
+ setpoints: {
1310
+ values: {
1311
+ occupiedHeatingSetpoint: { min: 5, max: 40, step: 0.5 },
1312
+ },
1313
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1314
+ },
1315
+ systemMode: {
1316
+ values: ["off", "heat"],
1317
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1318
+ },
1319
+ runningMode: {
1320
+ values: ["off", "heat"],
1321
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1322
+ },
1323
+ localTemperatureCalibration: {
1324
+ values: { min: -2.5, max: 2.5, step: 0.1 },
1325
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1326
+ },
1327
+ localTemperature: {
1328
+ configure: { reporting: { min: "1_MINUTE", max: "2_MINUTES", change: 50 } },
1329
+ },
1330
+ endpoint: "3",
1331
+ }),
1332
+ (0, modernExtend_1.thermostat)({
1333
+ setpoints: {
1334
+ values: {
1335
+ occupiedHeatingSetpoint: { min: 5, max: 40, step: 0.5 },
1336
+ },
1337
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1338
+ },
1339
+ systemMode: {
1340
+ values: ["off", "heat"],
1341
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1342
+ },
1343
+ runningMode: {
1344
+ values: ["off", "heat"],
1345
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1346
+ },
1347
+ localTemperatureCalibration: {
1348
+ values: { min: -2.5, max: 2.5, step: 0.1 },
1349
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1350
+ },
1351
+ localTemperature: {
1352
+ configure: { reporting: { min: "1_MINUTE", max: "2_MINUTES", change: 50 } },
1353
+ },
1354
+ endpoint: "4",
1355
+ }),
1356
+ (0, modernExtend_1.identify)(),
1357
+ (0, modernExtend_1.numeric)({
1358
+ name: "occupied_setback",
1359
+ description: "Hysteresis",
1360
+ unit: "°C",
1361
+ cluster: "hvacThermostat",
1362
+ attribute: "occupiedSetback",
1363
+ scale: 10,
1364
+ valueMin: 1.0,
1365
+ valueMax: 2.5,
1366
+ valueStep: 0.1,
1367
+ precision: 1,
1368
+ reporting: { min: "1_MINUTE", max: "1_HOUR", change: 1 },
1369
+ endpointNames: ["3", "4"],
1370
+ entityCategory: "config",
1371
+ }),
1372
+ (0, modernExtend_1.enumLookup)({
1373
+ name: "remote_sensing",
1374
+ label: "Remote sensing",
1375
+ description: "",
1376
+ lookup: { internally: 0, remotely: 1 },
1377
+ cluster: "hvacThermostat",
1378
+ attribute: "remoteSensing",
1379
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1380
+ endpointName: "3",
1381
+ entityCategory: "config",
1382
+ }),
1383
+ (0, modernExtend_1.enumLookup)({
1384
+ name: "remote_sensing",
1385
+ label: "Remote sensing",
1386
+ description: "",
1387
+ lookup: { internally: 0, remotely: 1 },
1388
+ cluster: "hvacThermostat",
1389
+ attribute: "remoteSensing",
1390
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1391
+ endpointName: "4",
1392
+ entityCategory: "config",
1393
+ }),
1394
+ (0, modernExtend_1.enumLookup)({
1395
+ name: "sensor_type",
1396
+ label: "Sensor",
1397
+ description: "Sensor type",
1398
+ lookup: { "3.3K": 0, "5.0K": 1, "6.8K": 2, "10.0K": 3, "12.0K": 4, "14.8K": 5, "15.0K": 6, "20.0K": 7, "33.0K": 8, "47.0K": 9 },
1399
+ cluster: "hvacThermostat",
1400
+ attribute: "lytkoSensor",
1401
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1402
+ endpointName: "3",
1403
+ zigbeeCommandOptions: manufacturerOptions,
1404
+ entityCategory: "config",
1405
+ }),
1406
+ (0, modernExtend_1.enumLookup)({
1407
+ name: "sensor_type",
1408
+ label: "Sensor",
1409
+ description: "Sensor type",
1410
+ lookup: { "3.3K": 0, "5.0K": 1, "6.8K": 2, "10.0K": 3, "12.0K": 4, "14.8K": 5, "15.0K": 6, "20.0K": 7, "33.0K": 8, "47.0K": 9 },
1411
+ cluster: "hvacThermostat",
1412
+ attribute: "lytkoSensor",
1413
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1414
+ endpointName: "4",
1415
+ zigbeeCommandOptions: manufacturerOptions,
1416
+ entityCategory: "config",
1417
+ }),
1418
+ (0, modernExtend_1.numeric)({
1419
+ name: "power_apparent",
1420
+ label: "Power Apparent",
1421
+ description: "Power apparent",
1422
+ unit: "VA",
1423
+ cluster: "haElectricalMeasurement",
1424
+ attribute: "apparentPower",
1425
+ precision: 1,
1426
+ reporting: { min: "1_MINUTE", max: "1_HOUR", change: 1 },
1427
+ access: "STATE_GET",
1428
+ endpointNames: ["3", "4"],
1429
+ }),
1430
+ (0, modernExtend_1.electricityMeter)({
1431
+ type: "electricity",
1432
+ cluster: "both",
1433
+ voltage: false,
1434
+ power: false,
1435
+ endpointNames: ["3", "4"],
1436
+ configureReporting: true,
1437
+ }),
1438
+ ],
1439
+ },
1440
+ {
1441
+ zigbeeModel: ["L101Ze-DBN"],
1442
+ model: "L101Ze-DBN",
1443
+ vendor: "LYTKO",
1444
+ description: "Lytko dual chanel thermostat with big display",
1445
+ ota: true,
1446
+ meta: { multiEndpoint: true },
1447
+ extend: [
1448
+ (0, modernExtend_1.deviceAddCustomCluster)("hvacThermostat", {
1449
+ ID: zigbee_herdsman_1.Zcl.Clusters.hvacThermostat.ID,
1450
+ attributes: {
1451
+ occupiedSetback: {
1452
+ ID: 0x0034,
1453
+ type: zigbee_herdsman_1.Zcl.DataType.UINT8,
1454
+ },
1455
+ lytkoSensor: {
1456
+ ID: 0xff00,
1457
+ type: zigbee_herdsman_1.Zcl.DataType.ENUM8,
1458
+ manufacturerCode: manufacturerOptions.manufacturerCode,
1459
+ },
1460
+ lytkoTargetFirst: {
1461
+ ID: 0xff01,
1462
+ type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN,
1463
+ manufacturerCode: manufacturerOptions.manufacturerCode,
1464
+ },
1465
+ },
1466
+ commands: {},
1467
+ commandsResponse: {},
1468
+ }),
1469
+ (0, modernExtend_1.deviceAddCustomCluster)("hvacUserInterfaceCfg", {
1470
+ ID: zigbee_herdsman_1.Zcl.Clusters.hvacUserInterfaceCfg.ID,
1471
+ attributes: {
1472
+ brignessActive: {
1473
+ ID: 0xff00,
1474
+ type: zigbee_herdsman_1.Zcl.DataType.ENUM8,
1475
+ manufacturerCode: manufacturerOptions.manufacturerCode,
1476
+ },
1477
+ brignessStandby: {
1478
+ ID: 0xff01,
1479
+ type: zigbee_herdsman_1.Zcl.DataType.ENUM8,
1480
+ manufacturerCode: manufacturerOptions.manufacturerCode,
1481
+ },
1482
+ },
1483
+ commands: {},
1484
+ commandsResponse: {},
1485
+ }),
1486
+ (0, modernExtend_1.deviceEndpoints)({
1487
+ endpoints: { 1: 1, 3: 3, 4: 4 },
1488
+ }),
1489
+ (0, modernExtend_1.thermostat)({
1490
+ setpoints: {
1491
+ values: {
1492
+ occupiedHeatingSetpoint: { min: 5, max: 40, step: 0.5 },
1493
+ },
1494
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1495
+ },
1496
+ systemMode: {
1497
+ values: ["off", "heat"],
1498
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1499
+ },
1500
+ runningMode: {
1501
+ values: ["off", "heat"],
1502
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1503
+ },
1504
+ localTemperatureCalibration: {
1505
+ values: { min: -2.5, max: 2.5, step: 0.1 },
1506
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1507
+ },
1508
+ localTemperature: {
1509
+ configure: { reporting: { min: "1_MINUTE", max: "2_MINUTES", change: 50 } },
1510
+ },
1511
+ endpoint: "3",
1512
+ }),
1513
+ (0, modernExtend_1.thermostat)({
1514
+ setpoints: {
1515
+ values: {
1516
+ occupiedHeatingSetpoint: { min: 5, max: 40, step: 0.5 },
1517
+ },
1518
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1519
+ },
1520
+ systemMode: {
1521
+ values: ["off", "heat"],
1522
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1523
+ },
1524
+ runningMode: {
1525
+ values: ["off", "heat"],
1526
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1527
+ },
1528
+ localTemperatureCalibration: {
1529
+ values: { min: -2.5, max: 2.5, step: 0.1 },
1530
+ configure: { reporting: { min: "1_SECOND", max: "2_MINUTES", change: 50 } },
1531
+ },
1532
+ localTemperature: {
1533
+ configure: { reporting: { min: "1_MINUTE", max: "2_MINUTES", change: 50 } },
1534
+ },
1535
+ endpoint: "4",
1536
+ }),
1537
+ (0, modernExtend_1.identify)(),
1538
+ (0, modernExtend_1.binary)({
1539
+ name: "child_lock",
1540
+ cluster: "hvacUserInterfaceCfg",
1541
+ attribute: "keypadLockout",
1542
+ description: "Enables/disables physical input on the device",
1543
+ access: "ALL",
1544
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1545
+ valueOn: ["lock", 1],
1546
+ valueOff: ["unlock", 0],
1547
+ entityCategory: "config",
1548
+ }),
1549
+ (0, modernExtend_1.numeric)({
1550
+ name: "brigness_Active",
1551
+ label: "Brigness Active",
1552
+ description: "Display brightness in work mode",
1553
+ unit: "%",
1554
+ cluster: "hvacUserInterfaceCfg",
1555
+ attribute: "brignessActive",
1556
+ valueMin: 0,
1557
+ valueMax: 100,
1558
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1559
+ access: "ALL",
1560
+ entityCategory: "config",
1561
+ }),
1562
+ (0, modernExtend_1.numeric)({
1563
+ name: "brigness_Standby",
1564
+ label: "Brigness Standby",
1565
+ description: "Display brightness in standby mode",
1566
+ unit: "%",
1567
+ cluster: "hvacUserInterfaceCfg",
1568
+ attribute: "brignessStandby",
1569
+ valueMin: 0,
1570
+ valueMax: 100,
1571
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1572
+ access: "ALL",
1573
+ entityCategory: "config",
1574
+ }),
1575
+ (0, modernExtend_1.numeric)({
1576
+ name: "occupied_setback",
1577
+ description: "Hysteresis",
1578
+ unit: "°C",
1579
+ cluster: "hvacThermostat",
1580
+ attribute: "occupiedSetback",
1581
+ scale: 10,
1582
+ valueMin: 1.0,
1583
+ valueMax: 2.5,
1584
+ valueStep: 0.1,
1585
+ precision: 1,
1586
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1587
+ endpointNames: ["3", "4"],
1588
+ }),
1589
+ (0, modernExtend_1.enumLookup)({
1590
+ name: "sensor_type_3",
1591
+ label: "Sensor",
1592
+ description: "Sensor type",
1593
+ lookup: { "3.3K": 0, "5.0K": 1, "6.8K": 2, "10.0K": 3, "12.0K": 4, "14.8K": 5, "15.0K": 6, "20.0K": 7, "33.0K": 8, "47.0K": 9 },
1594
+ cluster: "hvacThermostat",
1595
+ attribute: "lytkoSensor",
1596
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1597
+ endpointName: "3",
1598
+ zigbeeCommandOptions: manufacturerOptions,
1599
+ entityCategory: "config",
1600
+ }),
1601
+ (0, modernExtend_1.enumLookup)({
1602
+ name: "sensor_type_4",
1603
+ label: "Sensor",
1604
+ description: "Sensor type",
1605
+ lookup: { "3.3K": 0, "5.0K": 1, "6.8K": 2, "10.0K": 3, "12.0K": 4, "14.8K": 5, "15.0K": 6, "20.0K": 7, "33.0K": 8, "47.0K": 9 },
1606
+ cluster: "hvacThermostat",
1607
+ attribute: "lytkoSensor",
1608
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1609
+ endpointName: "4",
1610
+ zigbeeCommandOptions: manufacturerOptions,
1611
+ entityCategory: "config",
1612
+ }),
1613
+ (0, modernExtend_1.enumLookup)({
1614
+ name: "target_first_3",
1615
+ label: "First temperature",
1616
+ description: "Display target/current temperature first",
1617
+ lookup: { Target: 0, Current: 1 },
1618
+ cluster: "hvacThermostat",
1619
+ attribute: "lytkoTargetFirst",
1620
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1621
+ endpointName: "3",
1622
+ zigbeeCommandOptions: manufacturerOptions,
1623
+ entityCategory: "config",
1624
+ }),
1625
+ (0, modernExtend_1.enumLookup)({
1626
+ name: "target_first_4",
1627
+ label: "First temperature",
1628
+ description: "Display target/current temperature first",
1629
+ lookup: { Target: 0, Current: 1 },
1630
+ cluster: "hvacThermostat",
1631
+ attribute: "lytkoTargetFirst",
1632
+ reporting: { min: "1_SECOND", max: "1_HOUR", change: 1 },
1633
+ endpointName: "4",
1634
+ zigbeeCommandOptions: manufacturerOptions,
1635
+ entityCategory: "config",
1636
+ }),
1637
+ ],
1638
+ },
785
1639
  ];
786
1640
  //# sourceMappingURL=lytko.js.map