zigbee-herdsman-converters 21.33.0 → 21.35.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/devices/efekta.js CHANGED
@@ -39,6 +39,9 @@ const defaultReporting = { min: 0, max: 300, change: 0 };
39
39
  const normalReporting = { min: 0, max: 3600, change: 0 };
40
40
  const rareReporting = { min: 0, max: 21600, change: 0 };
41
41
  const rarestReporting = { min: 0, max: 64800, change: 0 };
42
+ const threeReporting = { min: 30, max: 1800, change: 1 };
43
+ const fourReporting = { min: 30, max: 1800, change: 10 };
44
+ const sixReporting = { min: 3600, max: 21600, change: 1 };
42
45
  const definitions = [
43
46
  {
44
47
  zigbeeModel: ['EFEKTA_iAQ3'],
@@ -1095,7 +1098,7 @@ const definitions = [
1095
1098
  }),
1096
1099
  m.enumLookup({
1097
1100
  name: 'tx_radio_power',
1098
- lookup: { '4': 4, '19': 19 },
1101
+ lookup: { '4dbm': 4, '19dbm': 19 },
1099
1102
  cluster: 'genPowerCfg',
1100
1103
  attribute: { ID: 0x0236, type: zigbee_herdsman_1.Zcl.DataType.INT8 },
1101
1104
  description: 'Set TX Radio Power, dbm',
@@ -1120,7 +1123,7 @@ const definitions = [
1120
1123
  }),
1121
1124
  m.enumLookup({
1122
1125
  name: 'fastmode',
1123
- lookup: { fast: 0, ultra_fast: 1 },
1126
+ lookup: { Fast: 0, 'Ultra Fast': 1 },
1124
1127
  cluster: 'genPowerCfg',
1125
1128
  attribute: { ID: 0xf005, type: zigbee_herdsman_1.Zcl.DataType.UINT8 },
1126
1129
  description: 'Display refresh mode',
@@ -1171,7 +1174,7 @@ const definitions = [
1171
1174
  }),
1172
1175
  m.enumLookup({
1173
1176
  name: 'tx_radio_power',
1174
- lookup: { '4': 4, '19': 19 },
1177
+ lookup: { '4dbm': 4, '19dbm': 19 },
1175
1178
  cluster: 'genPowerCfg',
1176
1179
  attribute: { ID: 0x0236, type: zigbee_herdsman_1.Zcl.DataType.INT8 },
1177
1180
  description: 'Set TX Radio Power, dbm',
@@ -1204,6 +1207,1426 @@ const definitions = [
1204
1207
  }),
1205
1208
  ],
1206
1209
  },
1210
+ {
1211
+ zigbeeModel: ['EFEKTA_T1_Y_LR'],
1212
+ model: 'EFEKTA_T1_Y_LR',
1213
+ vendor: 'EFEKTA',
1214
+ description: 'Temperature sensor DS18B20, AAA bsttery, signal amplifier, works in Tuya',
1215
+ extend: [
1216
+ m.temperature({
1217
+ reporting: false,
1218
+ access: 'STATE',
1219
+ }),
1220
+ m.battery({
1221
+ percentage: true,
1222
+ lowStatus: true,
1223
+ voltage: true,
1224
+ percentageReporting: false,
1225
+ voltageReporting: false,
1226
+ }),
1227
+ ],
1228
+ },
1229
+ {
1230
+ zigbeeModel: ['EFEKTA_T8_POW'],
1231
+ model: 'EFEKTA_T8_POW',
1232
+ vendor: 'EfektaLab',
1233
+ description: 'Temperature sensor with a signal amplifier, support up to 8 DS18B20',
1234
+ extend: [
1235
+ m.deviceEndpoints({
1236
+ endpoints: {
1237
+ '1': 1,
1238
+ '2': 2,
1239
+ '3': 3,
1240
+ '4': 4,
1241
+ '5': 5,
1242
+ '6': 6,
1243
+ '7': 7,
1244
+ '8': 8,
1245
+ },
1246
+ }),
1247
+ m.temperature({
1248
+ endpointNames: ['1'],
1249
+ description: 'Measured value of the 1 temperature sensor',
1250
+ reporting: fourReporting,
1251
+ access: 'STATE',
1252
+ }),
1253
+ m.temperature({
1254
+ endpointNames: ['2'],
1255
+ description: 'Measured value of the 2 temperature sensor',
1256
+ reporting: fourReporting,
1257
+ access: 'STATE',
1258
+ }),
1259
+ m.temperature({
1260
+ endpointNames: ['3'],
1261
+ description: 'Measured value of the 3 temperature sensor',
1262
+ reporting: fourReporting,
1263
+ access: 'STATE',
1264
+ }),
1265
+ m.temperature({
1266
+ endpointNames: ['4'],
1267
+ description: 'Measured value of the 4 temperature sensor',
1268
+ reporting: fourReporting,
1269
+ access: 'STATE',
1270
+ }),
1271
+ m.temperature({
1272
+ endpointNames: ['5'],
1273
+ description: 'Measured value of the 5 temperature sensor',
1274
+ reporting: fourReporting,
1275
+ access: 'STATE',
1276
+ }),
1277
+ m.temperature({
1278
+ endpointNames: ['6'],
1279
+ description: 'Measured value of the 6 temperature sensor',
1280
+ reporting: fourReporting,
1281
+ access: 'STATE',
1282
+ }),
1283
+ m.temperature({
1284
+ endpointNames: ['7'],
1285
+ description: 'Measured value of the 7 temperature sensor',
1286
+ reporting: fourReporting,
1287
+ access: 'STATE',
1288
+ }),
1289
+ m.temperature({
1290
+ endpointNames: ['8'],
1291
+ description: 'Measured value of the 8 temperature sensor',
1292
+ reporting: fourReporting,
1293
+ access: 'STATE',
1294
+ }),
1295
+ m.battery({
1296
+ percentage: true,
1297
+ lowStatus: true,
1298
+ voltage: false,
1299
+ percentageReporting: true,
1300
+ percentageReportingConfig: sixReporting,
1301
+ }),
1302
+ m.numeric({
1303
+ name: 'number_of_sensors',
1304
+ cluster: 'msTemperatureMeasurement',
1305
+ attribute: { ID: 0xa199, type: zigbee_herdsman_1.Zcl.DataType.UINT8 },
1306
+ description: 'Number of ds18b20 sensors per data bus',
1307
+ access: 'STATE',
1308
+ }),
1309
+ m.numeric({
1310
+ name: 'uptime',
1311
+ unit: 'Hours',
1312
+ cluster: 'genTime',
1313
+ attribute: 'localTime',
1314
+ description: 'Uptime',
1315
+ access: 'STATE',
1316
+ }),
1317
+ m.numeric({
1318
+ name: 'mains_voltage',
1319
+ unit: 'V',
1320
+ cluster: 'genPowerCfg',
1321
+ attribute: 'mainsVoltage',
1322
+ description: 'Mains voltage',
1323
+ scale: 10,
1324
+ precision: 1,
1325
+ access: 'STATE_GET',
1326
+ }),
1327
+ m.numeric({
1328
+ name: 'reading_interval',
1329
+ unit: 'sec',
1330
+ valueMin: 3,
1331
+ valueMax: 360,
1332
+ cluster: 'genPowerCfg',
1333
+ attribute: { ID: 0x0201, type: zigbee_herdsman_1.Zcl.DataType.UINT16 },
1334
+ description: 'Setting the sensor reading interval in seconds, by default 15 seconds',
1335
+ }),
1336
+ m.enumLookup({
1337
+ name: 'tx_radio_power',
1338
+ lookup: { '4dbm': 4, '19dbm': 19 },
1339
+ cluster: 'genPowerCfg',
1340
+ attribute: { ID: 0x0236, type: zigbee_herdsman_1.Zcl.DataType.INT8 },
1341
+ description: 'Set TX Radio Power, dbm',
1342
+ access: 'STATE_SET',
1343
+ }),
1344
+ m.binary({
1345
+ name: 'smart_sleep',
1346
+ valueOn: ['ON', 1],
1347
+ valueOff: ['OFF', 0],
1348
+ cluster: 'genPowerCfg',
1349
+ attribute: { ID: 0x0216, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
1350
+ description: 'Enable Smart Sleep, short wakeup every 2-7 seconds',
1351
+ }),
1352
+ ],
1353
+ },
1354
+ {
1355
+ zigbeeModel: ['EFEKTA_PST_V1_LR'],
1356
+ model: 'EFEKTA_PST_V1_LR',
1357
+ vendor: 'EFEKTA',
1358
+ description: 'Water, gas smart pressure monitor with signal amplifier',
1359
+ extend: [
1360
+ m.pressure({
1361
+ unit: 'kPa',
1362
+ description: 'Measured pressure value in kPa',
1363
+ scale: 10,
1364
+ reporting: threeReporting,
1365
+ access: 'STATE',
1366
+ }),
1367
+ m.numeric({
1368
+ name: 'bar',
1369
+ unit: 'bar',
1370
+ cluster: 'msPressureMeasurement',
1371
+ attribute: 'measuredValue',
1372
+ description: 'Measured pressure value in bar',
1373
+ scale: 1000,
1374
+ precision: 2,
1375
+ access: 'STATE',
1376
+ }),
1377
+ m.numeric({
1378
+ name: 'psi',
1379
+ unit: 'psi',
1380
+ cluster: 'msPressureMeasurement',
1381
+ attribute: 'measuredValue',
1382
+ description: 'Measured pressure value in psi',
1383
+ scale: 68.94757,
1384
+ precision: 2,
1385
+ access: 'STATE',
1386
+ }),
1387
+ m.temperature({
1388
+ reporting: fourReporting,
1389
+ access: 'STATE',
1390
+ }),
1391
+ m.numeric({
1392
+ name: 'pressure_offset',
1393
+ unit: 'kPa',
1394
+ valueMin: -100.0,
1395
+ valueMax: 100.0,
1396
+ cluster: 'msPressureMeasurement',
1397
+ attribute: { ID: 0x0210, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
1398
+ description: 'Adjust first pressure sensor',
1399
+ access: 'STATE_SET',
1400
+ }),
1401
+ m.numeric({
1402
+ name: 'raw_temperature_calibration',
1403
+ unit: 'raw unit',
1404
+ valueMin: -8192,
1405
+ valueMax: 8192,
1406
+ cluster: 'msTemperatureMeasurement',
1407
+ attribute: { ID: 0x0008, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
1408
+ description: 'Adjust first temperature sensor',
1409
+ access: 'STATE_SET',
1410
+ }),
1411
+ m.numeric({
1412
+ name: 'raw_temperature',
1413
+ unit: 'raw unit',
1414
+ cluster: 'msTemperatureMeasurement',
1415
+ attribute: { ID: 0x0007, type: zigbee_herdsman_1.Zcl.DataType.UINT16 },
1416
+ description: 'Sensor raw temperature',
1417
+ access: 'STATE',
1418
+ }),
1419
+ m.numeric({
1420
+ name: 'raw_temperature_recalibrated',
1421
+ unit: 'raw unit',
1422
+ cluster: 'msTemperatureMeasurement',
1423
+ attribute: { ID: 0x0009, type: zigbee_herdsman_1.Zcl.DataType.UINT16 },
1424
+ description: 'Recalibrated sensor raw temperature',
1425
+ access: 'STATE',
1426
+ }),
1427
+ m.battery({
1428
+ percentage: true,
1429
+ lowStatus: true,
1430
+ voltage: true,
1431
+ percentageReporting: true,
1432
+ voltageReporting: false,
1433
+ percentageReportingConfig: sixReporting,
1434
+ }),
1435
+ m.numeric({
1436
+ name: 'uptime',
1437
+ unit: 'Hours',
1438
+ cluster: 'genTime',
1439
+ attribute: 'localTime',
1440
+ description: 'Uptime',
1441
+ access: 'STATE',
1442
+ }),
1443
+ m.numeric({
1444
+ name: 'reading_interval',
1445
+ unit: 'sec',
1446
+ valueMin: 10,
1447
+ valueMax: 300,
1448
+ cluster: 'genPowerCfg',
1449
+ attribute: { ID: 0x0201, type: zigbee_herdsman_1.Zcl.DataType.UINT16 },
1450
+ description: 'Setting the sensor reading interval in seconds, by default 15 seconds',
1451
+ access: 'STATE_SET',
1452
+ }),
1453
+ m.enumLookup({
1454
+ name: 'tx_radio_power',
1455
+ lookup: { '4dbm': 4, '19dbm': 19 },
1456
+ cluster: 'genPowerCfg',
1457
+ attribute: { ID: 0x0236, type: zigbee_herdsman_1.Zcl.DataType.INT8 },
1458
+ description: 'Set TX Radio Power, dbm',
1459
+ access: 'STATE_SET',
1460
+ }),
1461
+ m.binary({
1462
+ name: 'smart_sleep',
1463
+ valueOn: ['ON', 1],
1464
+ valueOff: ['OFF', 0],
1465
+ cluster: 'genPowerCfg',
1466
+ attribute: { ID: 0x0216, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
1467
+ description: 'Enable Smart Sleep, short wakeup every 7 seconds',
1468
+ access: 'STATE_SET',
1469
+ }),
1470
+ m.binary({
1471
+ name: 'config_report_enable',
1472
+ valueOn: ['ON', 1],
1473
+ valueOff: ['OFF', 0],
1474
+ cluster: 'genPowerCfg',
1475
+ attribute: { ID: 0x0275, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
1476
+ description: 'Enable reporting based on reporting configuration',
1477
+ access: 'STATE_SET',
1478
+ }),
1479
+ m.binary({
1480
+ name: 'comparison_previous_data',
1481
+ valueOn: ['ON', 1],
1482
+ valueOff: ['OFF', 0],
1483
+ cluster: 'genPowerCfg',
1484
+ attribute: { ID: 0x0205, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
1485
+ description: 'Enable сontrol of comparison with previous data',
1486
+ access: 'STATE_SET',
1487
+ }),
1488
+ ],
1489
+ },
1490
+ {
1491
+ zigbeeModel: ['EFEKTA_PST_POW_V1_LR'],
1492
+ model: 'EFEKTA_PST_POW_V1_LR',
1493
+ vendor: 'EFEKTA',
1494
+ description: 'Water, gas smart pressure monitor with two types of power supply',
1495
+ extend: [
1496
+ m.pressure({
1497
+ unit: 'kPa',
1498
+ description: 'Measured pressure value in kPa',
1499
+ scale: 10,
1500
+ reporting: threeReporting,
1501
+ access: 'STATE',
1502
+ }),
1503
+ m.numeric({
1504
+ name: 'bar',
1505
+ unit: 'bar',
1506
+ cluster: 'msPressureMeasurement',
1507
+ attribute: 'measuredValue',
1508
+ description: 'Measured pressure value in bar',
1509
+ scale: 1000,
1510
+ precision: 2,
1511
+ access: 'STATE',
1512
+ }),
1513
+ m.numeric({
1514
+ name: 'psi',
1515
+ unit: 'psi',
1516
+ cluster: 'msPressureMeasurement',
1517
+ attribute: 'measuredValue',
1518
+ description: 'Measured pressure value in psi',
1519
+ scale: 68.94757,
1520
+ precision: 2,
1521
+ access: 'STATE',
1522
+ }),
1523
+ m.temperature({
1524
+ reporting: fourReporting,
1525
+ access: 'STATE',
1526
+ }),
1527
+ m.numeric({
1528
+ name: 'pressure_offset',
1529
+ unit: 'kPa',
1530
+ valueMin: -100.0,
1531
+ valueMax: 100.0,
1532
+ cluster: 'msPressureMeasurement',
1533
+ attribute: { ID: 0x0210, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
1534
+ description: 'Adjust first pressure sensor',
1535
+ access: 'STATE_SET',
1536
+ }),
1537
+ m.numeric({
1538
+ name: 'raw_temperature_calibration',
1539
+ unit: 'raw unit',
1540
+ valueMin: -8192,
1541
+ valueMax: 8192,
1542
+ cluster: 'msTemperatureMeasurement',
1543
+ attribute: { ID: 0x0008, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
1544
+ description: 'Adjust first temperature sensor',
1545
+ access: 'STATE_SET',
1546
+ }),
1547
+ m.numeric({
1548
+ name: 'mains_voltage',
1549
+ unit: 'V',
1550
+ cluster: 'genPowerCfg',
1551
+ attribute: 'mainsVoltage',
1552
+ description: 'Mains voltage',
1553
+ scale: 10,
1554
+ precision: 1,
1555
+ access: 'STATE_GET',
1556
+ }),
1557
+ m.battery({
1558
+ percentage: true,
1559
+ lowStatus: true,
1560
+ voltage: false,
1561
+ percentageReporting: true,
1562
+ percentageReportingConfig: sixReporting,
1563
+ }),
1564
+ m.numeric({
1565
+ name: 'uptime',
1566
+ unit: 'Hours',
1567
+ cluster: 'genTime',
1568
+ attribute: 'localTime',
1569
+ description: 'Uptime',
1570
+ access: 'STATE',
1571
+ }),
1572
+ m.numeric({
1573
+ name: 'reading_interval',
1574
+ unit: 'sec',
1575
+ valueMin: 10,
1576
+ valueMax: 360,
1577
+ cluster: 'genPowerCfg',
1578
+ attribute: { ID: 0x0201, type: zigbee_herdsman_1.Zcl.DataType.UINT16 },
1579
+ description: 'Setting the sensor reading interval in seconds, by default 10 seconds',
1580
+ access: 'STATE_SET',
1581
+ }),
1582
+ m.enumLookup({
1583
+ name: 'tx_radio_power',
1584
+ lookup: { '4dbm': 4, '19dbm': 19 },
1585
+ cluster: 'genPowerCfg',
1586
+ attribute: { ID: 0x0236, type: zigbee_herdsman_1.Zcl.DataType.INT8 },
1587
+ description: 'Set TX Radio Power, dbm',
1588
+ access: 'STATE_SET',
1589
+ }),
1590
+ m.binary({
1591
+ name: 'smart_sleep',
1592
+ valueOn: ['ON', 1],
1593
+ valueOff: ['OFF', 0],
1594
+ cluster: 'genPowerCfg',
1595
+ attribute: { ID: 0x0216, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
1596
+ description: 'Enable Smart Sleep, short wakeup every 2-7 seconds',
1597
+ access: 'STATE_SET',
1598
+ }),
1599
+ m.binary({
1600
+ name: 'config_report_enable',
1601
+ valueOn: ['ON', 1],
1602
+ valueOff: ['OFF', 0],
1603
+ cluster: 'genPowerCfg',
1604
+ attribute: { ID: 0x0275, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
1605
+ description: 'Enable reporting based on reporting configuration',
1606
+ access: 'STATE_SET',
1607
+ }),
1608
+ m.binary({
1609
+ name: 'comparison_previous_data',
1610
+ valueOn: ['ON', 1],
1611
+ valueOff: ['OFF', 0],
1612
+ cluster: 'genPowerCfg',
1613
+ attribute: { ID: 0x0205, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
1614
+ description: 'Enable сontrol of comparison with previous data',
1615
+ access: 'STATE_SET',
1616
+ }),
1617
+ ],
1618
+ },
1619
+ {
1620
+ zigbeeModel: ['EFEKTA_PST_POW_V2_LR'],
1621
+ model: 'EFEKTA_PST_POW_V2_LR',
1622
+ vendor: 'EFEKTA',
1623
+ description: 'Water, gas smart pressure monitor with two types of power supply V2',
1624
+ extend: [
1625
+ m.pressure({
1626
+ unit: 'kPa',
1627
+ description: 'Measured pressure value in kPa',
1628
+ scale: 10,
1629
+ reporting: threeReporting,
1630
+ access: 'STATE',
1631
+ }),
1632
+ m.numeric({
1633
+ name: 'bar',
1634
+ unit: 'bar',
1635
+ cluster: 'msPressureMeasurement',
1636
+ attribute: 'measuredValue',
1637
+ description: 'Measured pressure value in bar',
1638
+ scale: 1000,
1639
+ precision: 2,
1640
+ access: 'STATE',
1641
+ }),
1642
+ m.numeric({
1643
+ name: 'psi',
1644
+ unit: 'psi',
1645
+ cluster: 'msPressureMeasurement',
1646
+ attribute: 'measuredValue',
1647
+ description: 'Measured pressure value in psi',
1648
+ scale: 68.94757,
1649
+ precision: 2,
1650
+ access: 'STATE',
1651
+ }),
1652
+ m.temperature({
1653
+ reporting: fourReporting,
1654
+ access: 'STATE',
1655
+ }),
1656
+ m.numeric({
1657
+ name: 'pressure_offset',
1658
+ unit: 'kPa',
1659
+ valueMin: -100.0,
1660
+ valueMax: 100.0,
1661
+ cluster: 'msPressureMeasurement',
1662
+ attribute: { ID: 0x0210, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
1663
+ description: 'Adjust first pressure sensor',
1664
+ access: 'STATE_SET',
1665
+ }),
1666
+ m.numeric({
1667
+ name: 'raw_temperature_calibration',
1668
+ unit: 'raw unit',
1669
+ valueMin: -8192,
1670
+ valueMax: 8192,
1671
+ cluster: 'msTemperatureMeasurement',
1672
+ attribute: { ID: 0x0008, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
1673
+ description: 'Adjust first temperature sensor',
1674
+ access: 'STATE_SET',
1675
+ }),
1676
+ m.numeric({
1677
+ name: 'mains_voltage',
1678
+ unit: 'V',
1679
+ cluster: 'genPowerCfg',
1680
+ attribute: 'mainsVoltage',
1681
+ description: 'Mains voltage',
1682
+ scale: 10,
1683
+ precision: 1,
1684
+ access: 'STATE_GET',
1685
+ }),
1686
+ m.battery({
1687
+ percentage: true,
1688
+ lowStatus: true,
1689
+ voltage: false,
1690
+ percentageReporting: true,
1691
+ percentageReportingConfig: sixReporting,
1692
+ }),
1693
+ m.numeric({
1694
+ name: 'uptime',
1695
+ unit: 'Hours',
1696
+ cluster: 'genTime',
1697
+ attribute: 'localTime',
1698
+ description: 'Uptime',
1699
+ access: 'STATE',
1700
+ }),
1701
+ m.numeric({
1702
+ name: 'reading_interval',
1703
+ unit: 'sec',
1704
+ valueMin: 10,
1705
+ valueMax: 360,
1706
+ cluster: 'genPowerCfg',
1707
+ attribute: { ID: 0x0201, type: zigbee_herdsman_1.Zcl.DataType.UINT16 },
1708
+ description: 'Setting the sensor reading interval in seconds, by default 10 seconds',
1709
+ access: 'STATE_SET',
1710
+ }),
1711
+ m.enumLookup({
1712
+ name: 'tx_radio_power',
1713
+ lookup: { '4dbm': 4, '19dbm': 19 },
1714
+ cluster: 'genPowerCfg',
1715
+ attribute: { ID: 0x0236, type: zigbee_herdsman_1.Zcl.DataType.INT8 },
1716
+ description: 'Set TX Radio Power, dbm',
1717
+ access: 'STATE_SET',
1718
+ }),
1719
+ m.binary({
1720
+ name: 'smart_sleep',
1721
+ valueOn: ['ON', 1],
1722
+ valueOff: ['OFF', 0],
1723
+ cluster: 'genPowerCfg',
1724
+ attribute: { ID: 0x0216, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
1725
+ description: 'Enable Smart Sleep, short wakeup every 2-7 seconds',
1726
+ access: 'STATE_SET',
1727
+ }),
1728
+ m.binary({
1729
+ name: 'config_report_enable',
1730
+ valueOn: ['ON', 1],
1731
+ valueOff: ['OFF', 0],
1732
+ cluster: 'genPowerCfg',
1733
+ attribute: { ID: 0x0275, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
1734
+ description: 'Enable reporting based on reporting configuration',
1735
+ access: 'STATE_SET',
1736
+ }),
1737
+ m.binary({
1738
+ name: 'comparison_previous_data',
1739
+ valueOn: ['ON', 1],
1740
+ valueOff: ['OFF', 0],
1741
+ cluster: 'genPowerCfg',
1742
+ attribute: { ID: 0x0205, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
1743
+ description: 'Enable сontrol of comparison with previous data',
1744
+ access: 'STATE_SET',
1745
+ }),
1746
+ ],
1747
+ },
1748
+ {
1749
+ zigbeeModel: ['EFEKTA_PST_V1'],
1750
+ model: 'EFEKTA_PST_V1',
1751
+ vendor: 'EFEKTA',
1752
+ description: 'Water, gas smart pressure monitor',
1753
+ extend: [
1754
+ m.pressure({
1755
+ unit: 'kPa',
1756
+ description: 'Measured pressure value in kPa',
1757
+ scale: 10,
1758
+ reporting: threeReporting,
1759
+ access: 'STATE',
1760
+ }),
1761
+ m.numeric({
1762
+ name: 'bar',
1763
+ unit: 'bar',
1764
+ cluster: 'msPressureMeasurement',
1765
+ attribute: 'measuredValue',
1766
+ description: 'Measured pressure value in bar',
1767
+ scale: 1000,
1768
+ precision: 2,
1769
+ access: 'STATE',
1770
+ }),
1771
+ m.numeric({
1772
+ name: 'psi',
1773
+ unit: 'psi',
1774
+ cluster: 'msPressureMeasurement',
1775
+ attribute: 'measuredValue',
1776
+ description: 'Measured pressure value in psi',
1777
+ scale: 68.94757,
1778
+ precision: 2,
1779
+ access: 'STATE',
1780
+ }),
1781
+ m.temperature({
1782
+ reporting: fourReporting,
1783
+ access: 'STATE',
1784
+ }),
1785
+ m.numeric({
1786
+ name: 'pressure_offset',
1787
+ unit: 'kPa',
1788
+ valueMin: -100.0,
1789
+ valueMax: 100.0,
1790
+ cluster: 'msPressureMeasurement',
1791
+ attribute: { ID: 0x0210, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
1792
+ description: 'Adjust first pressure sensor',
1793
+ access: 'STATE_SET',
1794
+ }),
1795
+ m.numeric({
1796
+ name: 'raw_temperature_calibration',
1797
+ unit: 'raw unit',
1798
+ valueMin: -8192,
1799
+ valueMax: 8192,
1800
+ cluster: 'msTemperatureMeasurement',
1801
+ attribute: { ID: 0x0008, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
1802
+ description: 'Adjust first temperature sensor',
1803
+ access: 'STATE_SET',
1804
+ }),
1805
+ m.numeric({
1806
+ name: 'raw_temperature',
1807
+ unit: 'raw unit',
1808
+ cluster: 'msTemperatureMeasurement',
1809
+ attribute: { ID: 0x0007, type: zigbee_herdsman_1.Zcl.DataType.UINT16 },
1810
+ description: 'Sensor raw temperature',
1811
+ access: 'STATE',
1812
+ }),
1813
+ m.numeric({
1814
+ name: 'raw_temperature_recalibrated',
1815
+ unit: 'raw unit',
1816
+ cluster: 'msTemperatureMeasurement',
1817
+ attribute: { ID: 0x0009, type: zigbee_herdsman_1.Zcl.DataType.UINT16 },
1818
+ description: 'Recalibrated sensor raw temperature',
1819
+ access: 'STATE',
1820
+ }),
1821
+ m.battery({
1822
+ percentage: true,
1823
+ lowStatus: true,
1824
+ voltage: true,
1825
+ percentageReporting: true,
1826
+ voltageReporting: false,
1827
+ percentageReportingConfig: sixReporting,
1828
+ }),
1829
+ m.numeric({
1830
+ name: 'uptime',
1831
+ unit: 'Hours',
1832
+ cluster: 'genTime',
1833
+ attribute: 'localTime',
1834
+ description: 'Uptime',
1835
+ access: 'STATE',
1836
+ }),
1837
+ m.numeric({
1838
+ name: 'reading_interval',
1839
+ unit: 'sec',
1840
+ valueMin: 10,
1841
+ valueMax: 300,
1842
+ cluster: 'genPowerCfg',
1843
+ attribute: { ID: 0x0201, type: zigbee_herdsman_1.Zcl.DataType.INT8 },
1844
+ description: 'Setting the sensor reading interval in seconds, by default 15 seconds',
1845
+ access: 'STATE_SET',
1846
+ }),
1847
+ m.binary({
1848
+ name: 'smart_sleep',
1849
+ valueOn: ['ON', 1],
1850
+ valueOff: ['OFF', 0],
1851
+ cluster: 'genPowerCfg',
1852
+ attribute: { ID: 0x0216, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
1853
+ description: 'Enable Smart Sleep, short wakeup every 7 seconds',
1854
+ access: 'STATE_SET',
1855
+ }),
1856
+ m.binary({
1857
+ name: 'config_report_enable',
1858
+ valueOn: ['ON', 1],
1859
+ valueOff: ['OFF', 0],
1860
+ cluster: 'genPowerCfg',
1861
+ attribute: { ID: 0x0275, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
1862
+ description: 'Enable reporting based on reporting configuration',
1863
+ access: 'STATE_SET',
1864
+ }),
1865
+ m.binary({
1866
+ name: 'comparison_previous_data',
1867
+ valueOn: ['ON', 1],
1868
+ valueOff: ['OFF', 0],
1869
+ cluster: 'genPowerCfg',
1870
+ attribute: { ID: 0x0205, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
1871
+ description: 'Enable сontrol of comparison with previous data',
1872
+ access: 'STATE_SET',
1873
+ }),
1874
+ ],
1875
+ },
1876
+ {
1877
+ zigbeeModel: ['EFEKTA_PST_DUO_V1'],
1878
+ model: 'EFEKTA_PST_DUO_V1',
1879
+ vendor: 'EFEKTA',
1880
+ description: 'Water, gas smart pressure monitor with two sensors',
1881
+ extend: [
1882
+ m.deviceEndpoints({ endpoints: { '1': 1, '2': 2 } }),
1883
+ m.pressure({
1884
+ endpointNames: ['1'],
1885
+ unit: 'kPa',
1886
+ description: 'Measured pressure value оf the first sensor in kPa',
1887
+ scale: 10,
1888
+ reporting: threeReporting,
1889
+ access: 'STATE',
1890
+ }),
1891
+ m.numeric({
1892
+ endpointNames: ['1'],
1893
+ name: 'bar',
1894
+ unit: 'bar',
1895
+ cluster: 'msPressureMeasurement',
1896
+ attribute: 'measuredValue',
1897
+ description: 'Measured pressure value оf the first sensor in bar',
1898
+ scale: 1000,
1899
+ precision: 2,
1900
+ access: 'STATE',
1901
+ }),
1902
+ m.numeric({
1903
+ endpointNames: ['1'],
1904
+ name: 'psi',
1905
+ unit: 'psi',
1906
+ cluster: 'msPressureMeasurement',
1907
+ attribute: 'measuredValue',
1908
+ description: 'Measured pressure value оf the first sensor in psi',
1909
+ scale: 68.94757,
1910
+ precision: 2,
1911
+ access: 'STATE',
1912
+ }),
1913
+ m.temperature({
1914
+ endpointNames: ['1'],
1915
+ description: 'Measured value of the first temperature sensor',
1916
+ reporting: fourReporting,
1917
+ access: 'STATE',
1918
+ }),
1919
+ m.numeric({
1920
+ endpointNames: ['1'],
1921
+ name: 'pressure_offset',
1922
+ unit: 'kPa',
1923
+ valueMin: -100.0,
1924
+ valueMax: 100.0,
1925
+ cluster: 'msPressureMeasurement',
1926
+ attribute: { ID: 0x0210, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
1927
+ description: 'Adjust first pressure sensor',
1928
+ access: 'STATE_SET',
1929
+ }),
1930
+ m.numeric({
1931
+ endpointNames: ['1'],
1932
+ name: 'raw_temperature_calibration',
1933
+ unit: 'raw unit',
1934
+ valueMin: -8192,
1935
+ valueMax: 8192,
1936
+ cluster: 'msTemperatureMeasurement',
1937
+ attribute: { ID: 0x0008, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
1938
+ description: 'Adjust first temperature sensor',
1939
+ access: 'STATE_SET',
1940
+ }),
1941
+ m.pressure({
1942
+ endpointNames: ['2'],
1943
+ unit: 'kPa',
1944
+ description: 'Measured pressure value оf the second sensor in kPa',
1945
+ scale: 10,
1946
+ reporting: threeReporting,
1947
+ access: 'STATE',
1948
+ }),
1949
+ m.numeric({
1950
+ endpointNames: ['2'],
1951
+ name: 'bar',
1952
+ unit: 'bar',
1953
+ cluster: 'msPressureMeasurement',
1954
+ attribute: 'measuredValue',
1955
+ description: 'Measured pressure value оf the second sensor in bar',
1956
+ scale: 1000,
1957
+ precision: 2,
1958
+ access: 'STATE',
1959
+ }),
1960
+ m.numeric({
1961
+ endpointNames: ['2'],
1962
+ name: 'psi',
1963
+ unit: 'psi',
1964
+ cluster: 'msPressureMeasurement',
1965
+ attribute: 'measuredValue',
1966
+ description: 'pressure in psi',
1967
+ scale: 68.94757,
1968
+ precision: 2,
1969
+ access: 'STATE',
1970
+ }),
1971
+ m.temperature({
1972
+ endpointNames: ['2'],
1973
+ description: 'Measured value of the second temperature sensor',
1974
+ reporting: fourReporting,
1975
+ access: 'STATE',
1976
+ }),
1977
+ m.numeric({
1978
+ endpointNames: ['2'],
1979
+ name: 'pressure_offset',
1980
+ unit: 'kPa',
1981
+ valueMin: -100.0,
1982
+ valueMax: 100.0,
1983
+ cluster: 'msPressureMeasurement',
1984
+ attribute: { ID: 0x0210, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
1985
+ description: 'Adjust second pressure sensor',
1986
+ access: 'STATE_SET',
1987
+ }),
1988
+ m.numeric({
1989
+ endpointNames: ['2'],
1990
+ name: 'raw_temperature_cal',
1991
+ unit: 'raw unit',
1992
+ valueMin: -8192,
1993
+ valueMax: 8192,
1994
+ cluster: 'msTemperatureMeasurement',
1995
+ attribute: { ID: 0x0008, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
1996
+ description: 'Adjust second temperature sensor',
1997
+ access: 'STATE_SET',
1998
+ }),
1999
+ m.battery({
2000
+ percentage: true,
2001
+ lowStatus: true,
2002
+ voltage: true,
2003
+ percentageReporting: true,
2004
+ voltageReporting: false,
2005
+ percentageReportingConfig: sixReporting,
2006
+ }),
2007
+ m.numeric({
2008
+ name: 'uptime',
2009
+ unit: 'Hours',
2010
+ cluster: 'genTime',
2011
+ attribute: 'localTime',
2012
+ description: 'Uptime',
2013
+ access: 'STATE',
2014
+ }),
2015
+ m.numeric({
2016
+ name: 'reading_interval',
2017
+ unit: 'sec',
2018
+ valueMin: 10,
2019
+ valueMax: 360,
2020
+ cluster: 'genPowerCfg',
2021
+ attribute: { ID: 0x0201, type: zigbee_herdsman_1.Zcl.DataType.UINT16 },
2022
+ description: 'Setting sensor reading interval in seconds, by default 20 seconds',
2023
+ access: 'STATE_SET',
2024
+ }),
2025
+ m.binary({
2026
+ name: 'smart_sleep',
2027
+ valueOn: ['ON', 1],
2028
+ valueOff: ['OFF', 0],
2029
+ cluster: 'genPowerCfg',
2030
+ attribute: { ID: 0x0216, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
2031
+ description: 'Enable Smart Sleep, short wakeup every 7 seconds',
2032
+ access: 'STATE_SET',
2033
+ }),
2034
+ m.binary({
2035
+ name: 'config_report_enable',
2036
+ valueOn: ['ON', 1],
2037
+ valueOff: ['OFF', 0],
2038
+ cluster: 'genPowerCfg',
2039
+ attribute: { ID: 0x0275, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
2040
+ description: 'Enable reporting based on reporting configuration',
2041
+ access: 'STATE_SET',
2042
+ }),
2043
+ m.binary({
2044
+ name: 'comparison_previous_data',
2045
+ valueOn: ['ON', 1],
2046
+ valueOff: ['OFF', 0],
2047
+ cluster: 'genPowerCfg',
2048
+ attribute: { ID: 0x0205, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
2049
+ description: 'Enable сontrol of comparison with previous data',
2050
+ access: 'STATE_SET',
2051
+ }),
2052
+ ],
2053
+ },
2054
+ {
2055
+ zigbeeModel: ['EFEKTA_PST_DUO_V1_LR'],
2056
+ model: 'EFEKTA_PST_DUO_V1_LR',
2057
+ vendor: 'EFEKTA',
2058
+ description: 'Water, gas smart pressure monitor with two sensors and signal amplifier',
2059
+ extend: [
2060
+ m.deviceEndpoints({ endpoints: { '1': 1, '2': 2 } }),
2061
+ m.pressure({
2062
+ endpointNames: ['1'],
2063
+ unit: 'kPa',
2064
+ description: 'Measured pressure value оf the first sensor in kPa',
2065
+ scale: 10,
2066
+ reporting: threeReporting,
2067
+ access: 'STATE',
2068
+ }),
2069
+ m.numeric({
2070
+ endpointNames: ['1'],
2071
+ name: 'bar',
2072
+ unit: 'bar',
2073
+ cluster: 'msPressureMeasurement',
2074
+ attribute: 'measuredValue',
2075
+ description: 'Measured pressure value оf the first sensor in bar',
2076
+ scale: 1000,
2077
+ precision: 2,
2078
+ access: 'STATE',
2079
+ }),
2080
+ m.numeric({
2081
+ endpointNames: ['1'],
2082
+ name: 'psi',
2083
+ unit: 'psi',
2084
+ cluster: 'msPressureMeasurement',
2085
+ attribute: 'measuredValue',
2086
+ description: 'Measured pressure value оf the first sensor in psi',
2087
+ scale: 68.94757,
2088
+ precision: 2,
2089
+ access: 'STATE',
2090
+ }),
2091
+ m.temperature({
2092
+ endpointNames: ['1'],
2093
+ description: 'Measured value of the first temperature sensor',
2094
+ reporting: fourReporting,
2095
+ access: 'STATE',
2096
+ }),
2097
+ m.numeric({
2098
+ endpointNames: ['1'],
2099
+ name: 'pressure_offset',
2100
+ unit: 'kPa',
2101
+ valueMin: -100.0,
2102
+ valueMax: 100.0,
2103
+ cluster: 'msPressureMeasurement',
2104
+ attribute: { ID: 0x0210, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
2105
+ description: 'Adjust first pressure sensor',
2106
+ access: 'STATE_SET',
2107
+ }),
2108
+ m.numeric({
2109
+ endpointNames: ['1'],
2110
+ name: 'raw_temperature_cal',
2111
+ unit: 'raw unit',
2112
+ valueMin: -8192,
2113
+ valueMax: 8192,
2114
+ cluster: 'msTemperatureMeasurement',
2115
+ attribute: { ID: 0x0008, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
2116
+ description: 'Adjust first temperature sensor',
2117
+ access: 'STATE_SET',
2118
+ }),
2119
+ m.pressure({
2120
+ endpointNames: ['2'],
2121
+ unit: 'kPa',
2122
+ description: 'Measured pressure value оf the second sensor in kPa',
2123
+ scale: 10,
2124
+ reporting: threeReporting,
2125
+ access: 'STATE',
2126
+ }),
2127
+ m.numeric({
2128
+ endpointNames: ['2'],
2129
+ name: 'bar',
2130
+ unit: 'bar',
2131
+ cluster: 'msPressureMeasurement',
2132
+ attribute: 'measuredValue',
2133
+ description: 'Measured pressure value оf the second sensor in bar',
2134
+ scale: 1000,
2135
+ precision: 2,
2136
+ access: 'STATE',
2137
+ }),
2138
+ m.numeric({
2139
+ endpointNames: ['2'],
2140
+ name: 'psi',
2141
+ unit: 'psi',
2142
+ cluster: 'msPressureMeasurement',
2143
+ attribute: 'measuredValue',
2144
+ description: 'Measured pressure value оf the second sensor in psi',
2145
+ scale: 68.94757,
2146
+ precision: 2,
2147
+ access: 'STATE',
2148
+ }),
2149
+ m.temperature({
2150
+ endpointNames: ['2'],
2151
+ description: 'Measured value of the second temperature sensor',
2152
+ reporting: fourReporting,
2153
+ access: 'STATE',
2154
+ }),
2155
+ m.numeric({
2156
+ endpointNames: ['2'],
2157
+ name: 'pressure_offset',
2158
+ unit: 'kPa',
2159
+ valueMin: -100.0,
2160
+ valueMax: 100.0,
2161
+ cluster: 'msPressureMeasurement',
2162
+ attribute: { ID: 0x0210, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
2163
+ description: 'Adjust second pressure sensor',
2164
+ access: 'STATE_SET',
2165
+ }),
2166
+ m.numeric({
2167
+ endpointNames: ['2'],
2168
+ name: 'raw_temperature_calibration',
2169
+ unit: 'raw unit',
2170
+ valueMin: -8192,
2171
+ valueMax: 8192,
2172
+ cluster: 'msTemperatureMeasurement',
2173
+ attribute: { ID: 0x0008, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
2174
+ description: 'Adjust second temperature sensor',
2175
+ access: 'STATE_SET',
2176
+ }),
2177
+ m.battery({
2178
+ percentage: true,
2179
+ lowStatus: true,
2180
+ voltage: true,
2181
+ percentageReporting: true,
2182
+ voltageReporting: false,
2183
+ percentageReportingConfig: sixReporting,
2184
+ }),
2185
+ m.numeric({
2186
+ name: 'uptime',
2187
+ unit: 'Hours',
2188
+ cluster: 'genTime',
2189
+ attribute: 'localTime',
2190
+ description: 'Uptime',
2191
+ access: 'STATE',
2192
+ }),
2193
+ m.numeric({
2194
+ name: 'reading_interval',
2195
+ unit: 'sec',
2196
+ valueMin: 10,
2197
+ valueMax: 360,
2198
+ cluster: 'genPowerCfg',
2199
+ attribute: { ID: 0x0201, type: zigbee_herdsman_1.Zcl.DataType.UINT16 },
2200
+ description: 'Setting the sensor reading interval in seconds, by default 40 seconds',
2201
+ access: 'STATE_SET',
2202
+ }),
2203
+ m.enumLookup({
2204
+ name: 'tx_radio_power',
2205
+ lookup: { '4dbm': 4, '19dbm': 19 },
2206
+ cluster: 'genPowerCfg',
2207
+ attribute: { ID: 0x0236, type: zigbee_herdsman_1.Zcl.DataType.INT8 },
2208
+ description: 'Set TX Radio Power, dbm',
2209
+ access: 'STATE_SET',
2210
+ }),
2211
+ m.binary({
2212
+ name: 'smart_sleep',
2213
+ valueOn: ['ON', 1],
2214
+ valueOff: ['OFF', 0],
2215
+ cluster: 'genPowerCfg',
2216
+ attribute: { ID: 0x0216, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
2217
+ description: 'Enable Smart Sleep, short wakeup every 7 seconds',
2218
+ access: 'STATE_SET',
2219
+ }),
2220
+ m.binary({
2221
+ name: 'config_report_enable',
2222
+ valueOn: ['ON', 1],
2223
+ valueOff: ['OFF', 0],
2224
+ cluster: 'genPowerCfg',
2225
+ attribute: { ID: 0x0275, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
2226
+ description: 'Enable reporting based on reporting configuration',
2227
+ access: 'STATE_SET',
2228
+ }),
2229
+ m.binary({
2230
+ name: 'comparison_previous_data',
2231
+ valueOn: ['ON', 1],
2232
+ valueOff: ['OFF', 0],
2233
+ cluster: 'genPowerCfg',
2234
+ attribute: { ID: 0x0205, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
2235
+ description: 'Enable сontrol of comparison with previous data',
2236
+ access: 'STATE_SET',
2237
+ }),
2238
+ ],
2239
+ },
2240
+ {
2241
+ zigbeeModel: ['EFEKTA_PST_POW_DUO_V1_LR'],
2242
+ model: 'EFEKTA_PST_POW_DUO_V1_LR',
2243
+ vendor: 'EFEKTA',
2244
+ description: 'Water, gas smart pressure monitor with two sensors, two power supply',
2245
+ extend: [
2246
+ m.deviceEndpoints({ endpoints: { '1': 1, '2': 2 } }),
2247
+ m.pressure({
2248
+ endpointNames: ['1'],
2249
+ unit: 'kPa',
2250
+ description: 'Measured pressure value оf the first sensor in kPa',
2251
+ scale: 10,
2252
+ reporting: threeReporting,
2253
+ access: 'STATE',
2254
+ }),
2255
+ m.numeric({
2256
+ endpointNames: ['1'],
2257
+ name: 'bar',
2258
+ unit: 'bar',
2259
+ cluster: 'msPressureMeasurement',
2260
+ attribute: 'measuredValue',
2261
+ description: 'Measured pressure value оf the first sensor in bar',
2262
+ scale: 1000,
2263
+ precision: 2,
2264
+ access: 'STATE',
2265
+ }),
2266
+ m.numeric({
2267
+ endpointNames: ['1'],
2268
+ name: 'psi',
2269
+ unit: 'psi',
2270
+ cluster: 'msPressureMeasurement',
2271
+ attribute: 'measuredValue',
2272
+ description: 'Measured pressure value оf the first sensor in psi',
2273
+ scale: 68.94757,
2274
+ precision: 2,
2275
+ access: 'STATE',
2276
+ }),
2277
+ m.temperature({
2278
+ endpointNames: ['1'],
2279
+ description: 'Measured value of the first temperature sensor',
2280
+ reporting: fourReporting,
2281
+ access: 'STATE',
2282
+ }),
2283
+ m.numeric({
2284
+ endpointNames: ['1'],
2285
+ name: 'pressure_offset',
2286
+ unit: 'kPa',
2287
+ valueMin: -100.0,
2288
+ valueMax: 100.0,
2289
+ cluster: 'msPressureMeasurement',
2290
+ attribute: { ID: 0x0210, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
2291
+ description: 'Adjust first pressure sensor',
2292
+ access: 'STATE_SET',
2293
+ }),
2294
+ m.numeric({
2295
+ endpointNames: ['1'],
2296
+ name: 'raw_temperature_calibration',
2297
+ unit: 'raw unit',
2298
+ valueMin: -8192,
2299
+ valueMax: 8192,
2300
+ cluster: 'msTemperatureMeasurement',
2301
+ attribute: { ID: 0x0008, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
2302
+ description: 'Adjust first temperature sensor',
2303
+ access: 'STATE_SET',
2304
+ }),
2305
+ m.pressure({
2306
+ endpointNames: ['2'],
2307
+ unit: 'kPa',
2308
+ description: 'Measured pressure value оf the second sensor in kPa',
2309
+ scale: 10,
2310
+ reporting: threeReporting,
2311
+ access: 'STATE',
2312
+ }),
2313
+ m.numeric({
2314
+ endpointNames: ['2'],
2315
+ name: 'bar',
2316
+ unit: 'bar',
2317
+ cluster: 'msPressureMeasurement',
2318
+ attribute: 'measuredValue',
2319
+ description: 'Measured pressure value оf the second sensor in bar',
2320
+ scale: 1000,
2321
+ precision: 2,
2322
+ access: 'STATE',
2323
+ }),
2324
+ m.numeric({
2325
+ endpointNames: ['2'],
2326
+ name: 'psi',
2327
+ unit: 'psi',
2328
+ cluster: 'msPressureMeasurement',
2329
+ attribute: 'measuredValue',
2330
+ description: 'Measured pressure value оf the second sensor in psi',
2331
+ scale: 68.94757,
2332
+ precision: 2,
2333
+ access: 'STATE',
2334
+ }),
2335
+ m.temperature({
2336
+ endpointNames: ['2'],
2337
+ description: 'Measured value of the second temperature sensor',
2338
+ reporting: fourReporting,
2339
+ access: 'STATE',
2340
+ }),
2341
+ m.numeric({
2342
+ endpointNames: ['2'],
2343
+ name: 'pressure_offset',
2344
+ unit: 'kPa',
2345
+ valueMin: -100.0,
2346
+ valueMax: 100.0,
2347
+ cluster: 'msPressureMeasurement',
2348
+ attribute: { ID: 0x0210, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
2349
+ description: 'Adjust second pressure sensor',
2350
+ access: 'STATE_SET',
2351
+ }),
2352
+ m.numeric({
2353
+ endpointNames: ['2'],
2354
+ name: 'raw_temperature_calibration',
2355
+ unit: 'raw unit',
2356
+ valueMin: -8192,
2357
+ valueMax: 8192,
2358
+ cluster: 'msTemperatureMeasurement',
2359
+ attribute: { ID: 0x0008, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
2360
+ description: 'Adjust second temperature sensor',
2361
+ access: 'STATE_SET',
2362
+ }),
2363
+ m.numeric({
2364
+ name: 'mains_voltage',
2365
+ unit: 'V',
2366
+ cluster: 'genPowerCfg',
2367
+ attribute: 'mainsVoltage',
2368
+ description: 'Mains voltage',
2369
+ scale: 10,
2370
+ precision: 1,
2371
+ access: 'STATE_GET',
2372
+ }),
2373
+ m.battery({
2374
+ percentage: true,
2375
+ lowStatus: true,
2376
+ voltage: false,
2377
+ percentageReporting: true,
2378
+ percentageReportingConfig: sixReporting,
2379
+ }),
2380
+ m.numeric({
2381
+ name: 'uptime',
2382
+ unit: 'Hours',
2383
+ cluster: 'genTime',
2384
+ attribute: 'localTime',
2385
+ description: 'Uptime',
2386
+ access: 'STATE',
2387
+ }),
2388
+ m.numeric({
2389
+ name: 'reading_interval',
2390
+ unit: 'sec',
2391
+ valueMin: 10,
2392
+ valueMax: 360,
2393
+ cluster: 'genPowerCfg',
2394
+ attribute: { ID: 0x0201, type: zigbee_herdsman_1.Zcl.DataType.UINT16 },
2395
+ description: 'Setting the sensor reading interval in seconds, by default 10 seconds',
2396
+ access: 'STATE_SET',
2397
+ }),
2398
+ m.enumLookup({
2399
+ name: 'tx_radio_power',
2400
+ lookup: { '4dbm': 4, '19dbm': 19 },
2401
+ cluster: 'genPowerCfg',
2402
+ attribute: { ID: 0x0236, type: zigbee_herdsman_1.Zcl.DataType.INT8 },
2403
+ description: 'Set TX Radio Power, dbm',
2404
+ access: 'STATE_SET',
2405
+ }),
2406
+ m.binary({
2407
+ name: 'smart_sleep',
2408
+ valueOn: ['ON', 1],
2409
+ valueOff: ['OFF', 0],
2410
+ cluster: 'genPowerCfg',
2411
+ attribute: { ID: 0x0216, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
2412
+ description: 'Enable Smart Sleep, short wakeup every 2-7 seconds',
2413
+ access: 'STATE_SET',
2414
+ }),
2415
+ m.binary({
2416
+ name: 'config_report_enable',
2417
+ valueOn: ['ON', 1],
2418
+ valueOff: ['OFF', 0],
2419
+ cluster: 'genPowerCfg',
2420
+ attribute: { ID: 0x0275, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
2421
+ description: 'Enable reporting based on reporting configuration',
2422
+ access: 'STATE_SET',
2423
+ }),
2424
+ m.binary({
2425
+ name: 'comparison_previous_data',
2426
+ valueOn: ['ON', 1],
2427
+ valueOff: ['OFF', 0],
2428
+ cluster: 'genPowerCfg',
2429
+ attribute: { ID: 0x0205, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
2430
+ description: 'Enable сontrol of comparison with previous data',
2431
+ access: 'STATE_SET',
2432
+ }),
2433
+ ],
2434
+ },
2435
+ {
2436
+ zigbeeModel: ['EFEKTA_PST_POW_DUO_V2_LR'],
2437
+ model: 'EFEKTA_PST_POW_DUO_V2_LR',
2438
+ vendor: 'EFEKTA',
2439
+ description: 'Water, gas smart pressure monitor with two sensors, power supply, V2',
2440
+ extend: [
2441
+ m.deviceEndpoints({ endpoints: { '1': 1, '2': 2 } }),
2442
+ m.pressure({
2443
+ endpointNames: ['1'],
2444
+ unit: 'kPa',
2445
+ description: 'Measured pressure value оf the first sensor in kPa',
2446
+ scale: 10,
2447
+ reporting: threeReporting,
2448
+ access: 'STATE',
2449
+ }),
2450
+ m.numeric({
2451
+ endpointNames: ['1'],
2452
+ name: 'bar',
2453
+ unit: 'bar',
2454
+ cluster: 'msPressureMeasurement',
2455
+ attribute: 'measuredValue',
2456
+ description: 'Measured pressure value оf the first sensor in bar',
2457
+ scale: 1000,
2458
+ precision: 2,
2459
+ access: 'STATE',
2460
+ }),
2461
+ m.numeric({
2462
+ endpointNames: ['1'],
2463
+ name: 'psi',
2464
+ unit: 'psi',
2465
+ cluster: 'msPressureMeasurement',
2466
+ attribute: 'measuredValue',
2467
+ description: 'Measured pressure value оf the first sensor in psi',
2468
+ scale: 68.94757,
2469
+ precision: 2,
2470
+ access: 'STATE',
2471
+ }),
2472
+ m.temperature({
2473
+ endpointNames: ['1'],
2474
+ description: 'Measured value of the first temperature sensor',
2475
+ reporting: fourReporting,
2476
+ access: 'STATE',
2477
+ }),
2478
+ m.numeric({
2479
+ endpointNames: ['1'],
2480
+ name: 'pressure_offset',
2481
+ unit: 'kPa',
2482
+ valueMin: -100.0,
2483
+ valueMax: 100.0,
2484
+ cluster: 'msPressureMeasurement',
2485
+ attribute: { ID: 0x0210, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
2486
+ description: 'Adjust first pressure sensor',
2487
+ access: 'STATE_SET',
2488
+ }),
2489
+ m.numeric({
2490
+ endpointNames: ['1'],
2491
+ name: 'raw_temperature_calibration',
2492
+ unit: 'raw unit',
2493
+ valueMin: -8192,
2494
+ valueMax: 8192,
2495
+ cluster: 'msTemperatureMeasurement',
2496
+ attribute: { ID: 0x0008, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
2497
+ description: 'Adjust first temperature sensor',
2498
+ access: 'STATE_SET',
2499
+ }),
2500
+ m.pressure({
2501
+ endpointNames: ['2'],
2502
+ unit: 'kPa',
2503
+ description: 'Measured pressure value оf the second sensor in kPa',
2504
+ scale: 10,
2505
+ reporting: threeReporting,
2506
+ access: 'STATE',
2507
+ }),
2508
+ m.numeric({
2509
+ endpointNames: ['2'],
2510
+ name: 'bar',
2511
+ unit: 'bar',
2512
+ cluster: 'msPressureMeasurement',
2513
+ attribute: 'measuredValue',
2514
+ description: 'Measured pressure value оf the second sensor in bar',
2515
+ scale: 1000,
2516
+ precision: 2,
2517
+ access: 'STATE',
2518
+ }),
2519
+ m.numeric({
2520
+ endpointNames: ['2'],
2521
+ name: 'psi',
2522
+ unit: 'psi',
2523
+ cluster: 'msPressureMeasurement',
2524
+ attribute: 'measuredValue',
2525
+ description: 'Measured pressure value оf the second sensor in psi',
2526
+ scale: 68.94757,
2527
+ precision: 2,
2528
+ access: 'STATE',
2529
+ }),
2530
+ m.temperature({
2531
+ endpointNames: ['2'],
2532
+ description: 'Measured value of the second temperature sensor',
2533
+ reporting: fourReporting,
2534
+ access: 'STATE',
2535
+ }),
2536
+ m.numeric({
2537
+ endpointNames: ['2'],
2538
+ name: 'pressure_offset',
2539
+ unit: 'kPa',
2540
+ valueMin: -100.0,
2541
+ valueMax: 100.0,
2542
+ cluster: 'msPressureMeasurement',
2543
+ attribute: { ID: 0x0210, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
2544
+ description: 'Adjust second pressure sensor',
2545
+ access: 'STATE_SET',
2546
+ }),
2547
+ m.numeric({
2548
+ endpointNames: ['2'],
2549
+ name: 'raw_temperature_calibration',
2550
+ unit: 'raw unit',
2551
+ valueMin: -8192,
2552
+ valueMax: 8192,
2553
+ cluster: 'msTemperatureMeasurement',
2554
+ attribute: { ID: 0x0008, type: zigbee_herdsman_1.Zcl.DataType.INT16 },
2555
+ description: 'Adjust second temperature sensor',
2556
+ access: 'STATE_SET',
2557
+ }),
2558
+ m.numeric({
2559
+ name: 'mains_voltage',
2560
+ unit: 'V',
2561
+ cluster: 'genPowerCfg',
2562
+ attribute: 'mainsVoltage',
2563
+ description: 'Mains voltage',
2564
+ scale: 10,
2565
+ precision: 1,
2566
+ access: 'STATE_GET',
2567
+ }),
2568
+ m.battery({
2569
+ percentage: true,
2570
+ lowStatus: true,
2571
+ voltage: false,
2572
+ percentageReporting: true,
2573
+ percentageReportingConfig: sixReporting,
2574
+ }),
2575
+ m.numeric({
2576
+ name: 'uptime',
2577
+ unit: 'Hours',
2578
+ cluster: 'genTime',
2579
+ attribute: 'localTime',
2580
+ description: 'Uptime',
2581
+ access: 'STATE',
2582
+ }),
2583
+ m.numeric({
2584
+ name: 'reading_interval',
2585
+ unit: 'sec',
2586
+ valueMin: 10,
2587
+ valueMax: 360,
2588
+ cluster: 'genPowerCfg',
2589
+ attribute: { ID: 0x0201, type: zigbee_herdsman_1.Zcl.DataType.UINT16 },
2590
+ description: 'Setting the sensor reading interval in seconds, by default 10 seconds',
2591
+ access: 'STATE_SET',
2592
+ }),
2593
+ m.enumLookup({
2594
+ name: 'tx_radio_power',
2595
+ lookup: { '4dbm': 4, '19dbm': 19 },
2596
+ cluster: 'genPowerCfg',
2597
+ attribute: { ID: 0x0236, type: zigbee_herdsman_1.Zcl.DataType.INT8 },
2598
+ description: 'Set TX Radio Power, dbm',
2599
+ access: 'STATE_SET',
2600
+ }),
2601
+ m.binary({
2602
+ name: 'smart_sleep',
2603
+ valueOn: ['ON', 1],
2604
+ valueOff: ['OFF', 0],
2605
+ cluster: 'genPowerCfg',
2606
+ attribute: { ID: 0x0216, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
2607
+ description: 'Enable Smart Sleep, short wakeup every 2-7 seconds',
2608
+ access: 'STATE_SET',
2609
+ }),
2610
+ m.binary({
2611
+ name: 'config_report_enable',
2612
+ valueOn: ['ON', 1],
2613
+ valueOff: ['OFF', 0],
2614
+ cluster: 'genPowerCfg',
2615
+ attribute: { ID: 0x0275, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
2616
+ description: 'Enable reporting based on reporting configuration',
2617
+ access: 'STATE_SET',
2618
+ }),
2619
+ m.binary({
2620
+ name: 'comparison_previous_data',
2621
+ valueOn: ['ON', 1],
2622
+ valueOff: ['OFF', 0],
2623
+ cluster: 'genPowerCfg',
2624
+ attribute: { ID: 0x0205, type: zigbee_herdsman_1.Zcl.DataType.BOOLEAN },
2625
+ description: 'Enable сontrol of comparison with previous data',
2626
+ access: 'STATE_SET',
2627
+ }),
2628
+ ],
2629
+ },
1207
2630
  ];
1208
2631
  exports.default = definitions;
1209
2632
  module.exports = definitions;