periph 1.5.3 → 1.6.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/README.md +18 -0
- package/examples/color/isl29125/complete.js +57 -0
- package/examples/color/isl29125/demo.js +77 -0
- package/examples/color/isl29125/minimal.js +23 -0
- package/examples/environmental/bme688/complete.js +48 -0
- package/examples/environmental/bme688/demo.js +47 -0
- package/examples/environmental/bme688/minimal.js +21 -0
- package/examples/gas/ccs811/complete.js +87 -0
- package/examples/gas/ccs811/demo.js +108 -0
- package/examples/gas/ccs811/minimal.js +20 -0
- package/examples/gas/rrh46410/complete.js +78 -0
- package/examples/gas/rrh46410/demo.js +86 -0
- package/examples/gas/rrh46410/minimal.js +21 -0
- package/examples/humidity/hts221/complete.js +83 -0
- package/examples/humidity/hts221/demo.js +94 -0
- package/examples/humidity/hts221/minimal.js +22 -0
- package/examples/humidity/htu31d/complete.js +50 -0
- package/examples/humidity/htu31d/demo.js +65 -0
- package/examples/humidity/htu31d/minimal.js +22 -0
- package/examples/humidity/shtc3/complete.js +48 -0
- package/examples/humidity/shtc3/demo.js +45 -0
- package/examples/humidity/shtc3/minimal.js +22 -0
- package/examples/led/saa1064/complete.js +51 -0
- package/examples/led/saa1064/demo.js +54 -0
- package/examples/led/saa1064/minimal.js +23 -0
- package/examples/light/apds9250/complete.js +71 -0
- package/examples/light/apds9250/demo.js +79 -0
- package/examples/light/apds9250/minimal.js +23 -0
- package/examples/light/bh1750/complete.js +46 -0
- package/examples/light/bh1750/demo.js +52 -0
- package/examples/light/bh1750/minimal.js +22 -0
- package/examples/light/si1132/complete.js +70 -0
- package/examples/light/si1132/demo.js +73 -0
- package/examples/light/si1132/minimal.js +22 -0
- package/examples/light/si1133/complete.js +89 -0
- package/examples/light/si1133/demo.js +93 -0
- package/examples/light/si1133/minimal.js +22 -0
- package/examples/light/si1145/complete.js +93 -0
- package/examples/light/si1145/demo.js +98 -0
- package/examples/light/si1145/minimal.js +22 -0
- package/examples/pressure/mpl3115a2/complete.js +49 -0
- package/examples/pressure/mpl3115a2/demo.js +48 -0
- package/examples/pressure/mpl3115a2/minimal.js +22 -0
- package/examples/pressure/ms5607/complete.js +49 -0
- package/examples/pressure/ms5607/demo.js +65 -0
- package/examples/pressure/ms5607/minimal.js +22 -0
- package/examples/pressure/ms5611/complete.js +49 -0
- package/examples/pressure/ms5611/demo.js +65 -0
- package/examples/pressure/ms5611/minimal.js +22 -0
- package/examples/pressure/spl06/complete.js +81 -0
- package/examples/pressure/spl06/demo.js +106 -0
- package/examples/pressure/spl06/minimal.js +22 -0
- package/examples/rfid/pn532/complete.js +99 -0
- package/examples/rfid/pn532/demo.js +121 -0
- package/examples/rfid/pn532/minimal.js +22 -0
- package/package.json +1 -1
- package/src/chips/color/isl29125.js +379 -0
- package/src/chips/environmental/bme688.js +573 -0
- package/src/chips/gas/ccs811.js +400 -0
- package/src/chips/gas/rrh46410.js +534 -0
- package/src/chips/humidity/hts221.js +369 -0
- package/src/chips/humidity/htu31d.js +242 -0
- package/src/chips/humidity/shtc3.js +239 -0
- package/src/chips/led/saa1064.js +241 -0
- package/src/chips/light/apds9250.js +431 -0
- package/src/chips/light/bh1750.js +196 -0
- package/src/chips/light/si1132.js +416 -0
- package/src/chips/light/si1133.js +583 -0
- package/src/chips/light/si1145.js +630 -0
- package/src/chips/pressure/mpl3115a2.js +459 -0
- package/src/chips/pressure/ms5607.js +290 -0
- package/src/chips/pressure/ms5611.js +290 -0
- package/src/chips/pressure/spl06.js +461 -0
- package/src/chips/rfid/pn532.js +513 -0
- package/src/connection/i2c.js +46 -13
- package/src/connection/smbus.js +21 -8
- package/src/discovery/registry.js +18 -18
- package/examples/gpio/.gitkeep +0 -0
- package/src/chips/gpio/.gitkeep +0 -0
|
@@ -0,0 +1,78 @@
|
|
|
1
|
+
'use strict';
|
|
2
|
+
|
|
3
|
+
const { I2CConnection } = require('../../../src/connection/i2c');
|
|
4
|
+
const { RRH46410Full } = require('../../../src/chips/gas/rrh46410');
|
|
5
|
+
|
|
6
|
+
const I2C_BUS = parseInt(process.env.I2C_BUS || '1', 10);
|
|
7
|
+
const I2C_ADDR = parseInt(process.env.I2C_ADDR || '0x38', 16);
|
|
8
|
+
const sleep = (ms) => new Promise(r => setTimeout(r, ms));
|
|
9
|
+
|
|
10
|
+
const connection = new I2CConnection(I2C_BUS, I2C_ADDR); // Create I²C connection, (bus=1, addr=0x38) → Connection
|
|
11
|
+
// The module has the fixed address 0x38 and stretches the I²C clock.
|
|
12
|
+
const sensor = new RRH46410Full(connection); // Create RRH46410 driver, (connection) → void
|
|
13
|
+
// Constructor stores the connection only; no bus traffic yet.
|
|
14
|
+
|
|
15
|
+
async function main() {
|
|
16
|
+
await sensor.init(); // Check product ID, start IAQ 2nd Gen mode, () → void
|
|
17
|
+
// Retries Get Product ID for up to 1 s, verifies 0x2310, selects IAQ 2nd Gen (3 s samples).
|
|
18
|
+
|
|
19
|
+
console.log(await sensor.productId()); // Product ID and firmware, () → {productId, firmware: [major, minor, patch]}
|
|
20
|
+
// The product ID is always 0x2310.
|
|
21
|
+
console.log(await sensor.trackingNumber()); // ASIC tracking number, () → Buffer (6)
|
|
22
|
+
// Unique per module.
|
|
23
|
+
console.log(await sensor.getMode()); // Operation mode, () → number
|
|
24
|
+
// 1 = IAQ 2nd Gen after init.
|
|
25
|
+
|
|
26
|
+
await sensor.setHumidity(45.0); // Ambient humidity, (percent %RH) → void
|
|
27
|
+
// Sent as round(percent / 100 × 255); the module assumes 50 %RH otherwise.
|
|
28
|
+
console.log(await sensor.read()); // Next sample, () → {iaq, tvoc_mg_m3 mg/m³, etoh_ppm ppm, eco2_ppm ppm, relative_iaq, sample, warmed_up}
|
|
29
|
+
// Waits for the sample counter to change; values are fixed during the warm-up.
|
|
30
|
+
console.log(await sensor.waitForSample(4.0)); // Wait for a new sample, (timeout s) → boolean
|
|
31
|
+
// True when the counter changed (or INT went high) within the timeout.
|
|
32
|
+
console.log(await sensor.readResults()); // Latest result, () → object|null
|
|
33
|
+
// Does not wait; null before the first sample of the mode.
|
|
34
|
+
console.log(RRH46410Full.airQualityLabel(2.4)); // UBA rating, (iaq) → string
|
|
35
|
+
// "very good", "good", "medium", "poor" or "bad".
|
|
36
|
+
console.log(sensor.samplePeriod(), sensor.warmupSamples()); // Mode timing, (mode=null) → number s / number
|
|
37
|
+
// 3 s and 100 samples in IAQ 2nd Gen mode.
|
|
38
|
+
console.log(sensor.status()); // Last status byte, () → object
|
|
39
|
+
// Error bits and the operation-mode error code (0xA = sensor damaged).
|
|
40
|
+
|
|
41
|
+
await sensor.onInterrupt((r) => console.log('sample', r.sample, r.iaq)); // Subscribe, (callback, intPin=null) → void
|
|
42
|
+
// Rising edge on INT, or a 200 ms poll comparing the sample counter.
|
|
43
|
+
await sleep(7000);
|
|
44
|
+
await sensor.offInterrupt(); // Unsubscribe, () → void
|
|
45
|
+
// Stops the pin handler or polling timer.
|
|
46
|
+
console.log(await sensor.pollInterrupt()); // New sample pending, () → boolean
|
|
47
|
+
// INT level if wired, otherwise a counter comparison.
|
|
48
|
+
|
|
49
|
+
await sensor.setMode(RRH46410Full.MODE_PBAQ); // Operation mode, (mode) → void
|
|
50
|
+
// PBAQ: TVOC and ethanol only, every 5 s; restarts the warm-up.
|
|
51
|
+
console.log(await sensor.read()); // Next sample, () → {tvoc_mg_m3, etoh_ppm, sample, warmed_up}
|
|
52
|
+
// PBAQ results have a finer resolution (raw / 1000).
|
|
53
|
+
await sensor.setMode(RRH46410Full.MODE_ULP); // Operation mode, (mode) → void
|
|
54
|
+
// ULP: one sample every 90 s at 0.23 mW.
|
|
55
|
+
console.log(sensor.samplePeriod(), sensor.warmupSamples()); // Mode timing, (mode=null) → number s / number
|
|
56
|
+
// 90 s and 10 samples.
|
|
57
|
+
|
|
58
|
+
await sensor.configGpio(0x03); // GPIO directions, (directions) → void
|
|
59
|
+
// Bit 0 = GPIO1 output, bit 1 = GPIO2 output.
|
|
60
|
+
await sensor.setGpio(0x01); // Drive high, (mask) → void
|
|
61
|
+
// GPIO1 high.
|
|
62
|
+
console.log((await sensor.getGpio()).toString(2)); // GPIO levels, () → number
|
|
63
|
+
// Bits 0–3 = GPIO1–GPIO4.
|
|
64
|
+
await sensor.clearGpio(0x01); // Drive low, (mask) → void
|
|
65
|
+
// GPIO1 low.
|
|
66
|
+
|
|
67
|
+
console.log(await sensor.sendCommand(0x10, [], 1)); // Raw request, (command, params=[], responseLen=0) → Buffer
|
|
68
|
+
// Checksums added and verified; here Get Operation Mode.
|
|
69
|
+
// await sensor.cleanSensor(true); // One-time cleaning, (confirm=false) → void
|
|
70
|
+
// Runs for one minute, once in the sensor's lifetime; left disabled here.
|
|
71
|
+
await sensor.suspend(); // Suspend mode, () → void
|
|
72
|
+
// Stops measuring, about 0.7 µA.
|
|
73
|
+
await sensor.reset(); // Reset, () → void
|
|
74
|
+
// Waits 500 ms and verifies the product ID; the module restarts in SUSPEND.
|
|
75
|
+
await connection.close();
|
|
76
|
+
}
|
|
77
|
+
|
|
78
|
+
main().catch(err => { console.error(err); process.exit(1); });
|
|
@@ -0,0 +1,86 @@
|
|
|
1
|
+
'use strict';
|
|
2
|
+
|
|
3
|
+
const { I2CConnection } = require('../../../src/connection/i2c');
|
|
4
|
+
const { RRH46410Full } = require('../../../src/chips/gas/rrh46410');
|
|
5
|
+
|
|
6
|
+
const I2C_BUS = parseInt(process.env.I2C_BUS || '1', 10);
|
|
7
|
+
const I2C_ADDR = parseInt(process.env.I2C_ADDR || '0x38', 16);
|
|
8
|
+
const sleep = (ms) => new Promise(r => setTimeout(r, ms));
|
|
9
|
+
|
|
10
|
+
const connection = new I2CConnection(I2C_BUS, I2C_ADDR); // Create I²C connection, (bus=1, addr=0x38) → Connection
|
|
11
|
+
const sensor = new RRH46410Full(connection); // Create RRH46410 driver, (connection) → void
|
|
12
|
+
|
|
13
|
+
async function main() {
|
|
14
|
+
await sensor.init(); // Check product ID, start IAQ 2nd Gen mode, () → void
|
|
15
|
+
|
|
16
|
+
// --- Identity ---
|
|
17
|
+
// Get Product ID returns 0x2310 and the firmware version; the tracking number
|
|
18
|
+
// identifies the individual module.
|
|
19
|
+
const { productId, firmware } = await sensor.productId(); // Product ID and firmware, () → {productId, firmware}
|
|
20
|
+
console.log('product 0x%s, firmware %s', productId.toString(16), firmware.join('.'));
|
|
21
|
+
console.log('tracking', (await sensor.trackingNumber()).toString('hex')); // Tracking number, () → Buffer
|
|
22
|
+
console.log('mode', await sensor.getMode()); // Operation mode, () → number
|
|
23
|
+
|
|
24
|
+
// --- Humidity compensation ---
|
|
25
|
+
// The MOx element reacts to humidity; feeding the real value (e.g. from a
|
|
26
|
+
// humidity sensor) improves the results. The module assumes 50 %RH.
|
|
27
|
+
await sensor.setHumidity(42.0); // Ambient humidity, (percent %RH) → void
|
|
28
|
+
|
|
29
|
+
// --- Indoor air-quality monitor ---
|
|
30
|
+
// A new sample arrives every 3 s; the first 100 samples (about 5 min) are the
|
|
31
|
+
// warm-up during which the values stay fixed.
|
|
32
|
+
const warmup = sensor.warmupSamples(); // Warm-up length, (mode=null) → number samples
|
|
33
|
+
console.log('sample period %d s, warm-up %d samples', sensor.samplePeriod(), warmup); // Sample period, (mode=null) → number s
|
|
34
|
+
for (let i = 0; i < 20; i++) {
|
|
35
|
+
const r = await sensor.read(); // Next sample, () → object
|
|
36
|
+
const progress = r.warmed_up ? 'ok' : `warm-up ${Math.min(100, Math.floor(r.sample * 100 / warmup))}%`;
|
|
37
|
+
console.log('IAQ %s (%s) TVOC %s mg/m3 EtOH %s ppm eCO2 %d ppm rel %d %s', r.iaq.toFixed(1),
|
|
38
|
+
sensor.airQualityLabel(r.iaq), r.tvoc_mg_m3.toFixed(2), // UBA rating, (iaq) → string
|
|
39
|
+
r.etoh_ppm.toFixed(2), r.eco2_ppm, r.relative_iaq, progress);
|
|
40
|
+
}
|
|
41
|
+
|
|
42
|
+
// --- Interrupt instead of polling ---
|
|
43
|
+
// With INT wired the driver reacts to its rising edge; otherwise it polls the
|
|
44
|
+
// sample counter. The callback receives the decoded result.
|
|
45
|
+
await sensor.onInterrupt((r) => console.log('INT sample %d IAQ %s', r.sample, r.iaq.toFixed(1))); // Subscribe, (callback, intPin=null) → void
|
|
46
|
+
await sleep(10000);
|
|
47
|
+
await sensor.offInterrupt(); // Unsubscribe, () → void
|
|
48
|
+
while (!(await sensor.pollInterrupt())) await sleep(500); // New sample pending, () → boolean
|
|
49
|
+
if (await sensor.waitForSample(4.0)) { // Wait for a new sample, (timeout s) → boolean
|
|
50
|
+
console.log('latest', await sensor.readResults()); // Latest result, () → object|null
|
|
51
|
+
}
|
|
52
|
+
|
|
53
|
+
// --- Other operation modes ---
|
|
54
|
+
// PBAQ reports TVOC and ethanol for public buildings; ULP saves power with
|
|
55
|
+
// one sample every 90 s. Each mode change restarts the warm-up.
|
|
56
|
+
for (const [mode, name] of [[RRH46410Full.MODE_PBAQ, 'PBAQ'], [RRH46410Full.MODE_ULP, 'ULP']]) {
|
|
57
|
+
await sensor.setMode(mode); // Operation mode, (mode) → void
|
|
58
|
+
console.log('%s: sample every %d s, warm-up %d samples (%d min)', name, sensor.samplePeriod(),
|
|
59
|
+
sensor.warmupSamples(), sensor.samplePeriod() * sensor.warmupSamples() / 60); // Mode timing, (mode=null) → number
|
|
60
|
+
}
|
|
61
|
+
await sensor.setMode(RRH46410Full.MODE_PBAQ); // Operation mode, (mode) → void
|
|
62
|
+
console.log('PBAQ', await sensor.read()); // Next sample, () → {tvoc_mg_m3, etoh_ppm, sample, warmed_up}
|
|
63
|
+
|
|
64
|
+
// --- GPIOs ---
|
|
65
|
+
// GPIO1 and GPIO2 can drive an indicator LED or a fan relay.
|
|
66
|
+
await sensor.configGpio(0x03); // Both outputs, (directions) → void
|
|
67
|
+
for (let i = 0; i < 3; i++) {
|
|
68
|
+
await sensor.setGpio(0x01); // GPIO1 high, (mask) → void
|
|
69
|
+
await sleep(200);
|
|
70
|
+
await sensor.clearGpio(0x01); // GPIO1 low, (mask) → void
|
|
71
|
+
await sleep(200);
|
|
72
|
+
}
|
|
73
|
+
console.log('GPIO levels', (await sensor.getGpio()).toString(2)); // GPIO levels, () → number
|
|
74
|
+
console.log('status', sensor.status()); // Last status byte, () → object
|
|
75
|
+
console.log('raw mode', (await sensor.sendCommand(0x10, [], 1))[0]); // Raw request, (command, params, responseLen) → Buffer
|
|
76
|
+
|
|
77
|
+
// --- Wrap up ---
|
|
78
|
+
// cleanSensor(true) runs the 1-minute cleaning once in the sensor's lifetime;
|
|
79
|
+
// it is skipped here. Suspend stops measuring; reset restarts the module in SUSPEND.
|
|
80
|
+
await sensor.suspend(); // Suspend mode, () → void
|
|
81
|
+
await sensor.reset(); // Reset, () → void
|
|
82
|
+
console.log('mode after reset', await sensor.getMode()); // Operation mode, () → number
|
|
83
|
+
await connection.close();
|
|
84
|
+
}
|
|
85
|
+
|
|
86
|
+
main().catch(err => { console.error(err); process.exit(1); });
|
|
@@ -0,0 +1,21 @@
|
|
|
1
|
+
'use strict';
|
|
2
|
+
|
|
3
|
+
const { I2CConnection } = require('../../../src/connection/i2c');
|
|
4
|
+
const { RRH46410Minimal } = require('../../../src/chips/gas/rrh46410');
|
|
5
|
+
|
|
6
|
+
const I2C_BUS = parseInt(process.env.I2C_BUS || '1', 10);
|
|
7
|
+
const I2C_ADDR = parseInt(process.env.I2C_ADDR || '0x38', 16);
|
|
8
|
+
|
|
9
|
+
const connection = new I2CConnection(I2C_BUS, I2C_ADDR); // Create I²C connection, (bus=1, addr=0x38) → Connection
|
|
10
|
+
const sensor = new RRH46410Minimal(connection); // Create RRH46410 driver, (connection) → void
|
|
11
|
+
|
|
12
|
+
async function main() {
|
|
13
|
+
await sensor.init(); // Check product ID, start IAQ 2nd Gen mode, () → void
|
|
14
|
+
while (true) {
|
|
15
|
+
const r = await sensor.read(); // Wait for the next sample, () → {iaq, tvoc_mg_m3 mg/m³, etoh_ppm ppm, eco2_ppm ppm, relative_iaq, sample, warmed_up}
|
|
16
|
+
console.log('IAQ %s TVOC %s mg/m3 EtOH %s ppm eCO2 %d ppm %s', r.iaq.toFixed(1), r.tvoc_mg_m3.toFixed(2),
|
|
17
|
+
r.etoh_ppm.toFixed(2), r.eco2_ppm, r.warmed_up ? 'ok' : 'warming up');
|
|
18
|
+
}
|
|
19
|
+
}
|
|
20
|
+
|
|
21
|
+
main().catch(err => { console.error(err); process.exit(1); });
|
|
@@ -0,0 +1,83 @@
|
|
|
1
|
+
'use strict';
|
|
2
|
+
|
|
3
|
+
const { I2CConnection } = require('../../../src/connection/i2c');
|
|
4
|
+
const { HTS221Full } = require('../../../src/chips/humidity/hts221');
|
|
5
|
+
|
|
6
|
+
const I2C_BUS = parseInt(process.env.I2C_BUS || '1', 10);
|
|
7
|
+
const I2C_ADDR = parseInt(process.env.I2C_ADDR || '0x5F', 16);
|
|
8
|
+
const sleep = (ms) => new Promise(r => setTimeout(r, ms));
|
|
9
|
+
|
|
10
|
+
const connection = new I2CConnection(I2C_BUS, I2C_ADDR); // Create I²C connection, (bus=1, addr=0x5F) → Connection
|
|
11
|
+
const sensor = new HTS221Full(connection); // Create HTS221 driver, (connection) → void
|
|
12
|
+
|
|
13
|
+
async function main() {
|
|
14
|
+
await sensor.init(); // Read calibration and start one-shot mode, () → void
|
|
15
|
+
// decodes the per-device two-point calibration
|
|
16
|
+
console.log('who am i 0x' + (await sensor.whoAmI()).toString(16)); // Read WHO_AM_I, () → number (0xBC)
|
|
17
|
+
// identifies the chip on the bus
|
|
18
|
+
const m = await sensor.read(); // Read temperature and humidity, () → {temperature_c °C, humidity_pct %rH}
|
|
19
|
+
// one-shot conversion, converted with the calibration
|
|
20
|
+
console.log(m.temperature_c.toFixed(2) + ' C', m.humidity_pct.toFixed(1) + ' %rH');
|
|
21
|
+
console.log('humidity', (await sensor.readHumidity()).toFixed(1)); // Read humidity only, () → number %rH
|
|
22
|
+
// one-shot conversion, clamped to 0–100
|
|
23
|
+
console.log('temperature', (await sensor.readTemperature()).toFixed(2)); // Read temperature only, () → number °C
|
|
24
|
+
// one-shot conversion
|
|
25
|
+
console.log('raw humidity', await sensor.readRawHumidity()); // Read raw humidity, () → number
|
|
26
|
+
// signed 16-bit ADC output
|
|
27
|
+
console.log('raw temperature', await sensor.readRawTemperature()); // Read raw temperature, () → number
|
|
28
|
+
// signed 16-bit ADC output
|
|
29
|
+
console.log('calibration', await sensor.readCalibration()); // Read calibration, () → object
|
|
30
|
+
// decoded two-point coefficients
|
|
31
|
+
console.log('dew point', (await sensor.dewPoint()).toFixed(2)); // Compute dew point, () → number °C
|
|
32
|
+
// Magnus formula over one measurement
|
|
33
|
+
console.log('status', await sensor.status()); // Read STATUS_REG, () → number
|
|
34
|
+
// H_DA = 0x02, T_DA = 0x01
|
|
35
|
+
console.log('data ready', await sensor.dataReady()); // Check data available, () → boolean
|
|
36
|
+
// both H_DA and T_DA set
|
|
37
|
+
|
|
38
|
+
await sensor.setOutputDataRate(1); // Set output data rate, (hz 0|1|7|12.5) → void
|
|
39
|
+
// continuous sampling at 1 Hz
|
|
40
|
+
console.log('rate', await sensor.getOutputDataRate(), 'Hz'); // Get output data rate, () → number Hz
|
|
41
|
+
// decodes CTRL_REG1.ODR
|
|
42
|
+
await sleep(1200);
|
|
43
|
+
const c = await sensor.readContinuous(); // Read latest sample, () → {temperature_c °C, humidity_pct %rH}
|
|
44
|
+
// no conversion is started
|
|
45
|
+
console.log('continuous', c);
|
|
46
|
+
await sensor.setOutputDataRate(0); // Set output data rate, (hz 0|1|7|12.5) → void
|
|
47
|
+
// back to one-shot mode
|
|
48
|
+
|
|
49
|
+
await sensor.setAveraging(32, 64); // Set averaging, (temperatureSamples 2–256, humiditySamples 4–512) → void
|
|
50
|
+
// more samples lower the noise and lengthen the conversion
|
|
51
|
+
console.log('averaging', await sensor.getAveraging()); // Get averaging, () → [number, number]
|
|
52
|
+
// [temperature samples, humidity samples]
|
|
53
|
+
await sensor.setAveraging(16, 32);
|
|
54
|
+
await sensor.setBlockDataUpdate(true); // Set block data update, (enabled) → void
|
|
55
|
+
// keeps LSB/MSB of one sample consistent
|
|
56
|
+
|
|
57
|
+
await sensor.setHeater(true); // Switch the heater, (on) → void
|
|
58
|
+
// drives off condensation; do not measure while on
|
|
59
|
+
console.log('heater on:', await sensor.isHeaterOn()); // Heater state, () → boolean
|
|
60
|
+
// reads CTRL_REG2.HEATER
|
|
61
|
+
await sensor.setHeater(false);
|
|
62
|
+
|
|
63
|
+
await sensor.configureDrdy(true, true, false); // Configure DRDY pin, (enabled, activeHigh=true, openDrain=false) → void
|
|
64
|
+
// routes data-ready to the DRDY pin
|
|
65
|
+
console.log('poll', await sensor.pollInterrupt()); // Poll interrupt status, () → number
|
|
66
|
+
// STATUS_REG; flags clear when data is read
|
|
67
|
+
await sensor.configureDrdy(false);
|
|
68
|
+
|
|
69
|
+
await sensor.powerDown(); // Power down, () → void
|
|
70
|
+
// clears CTRL_REG1.PD
|
|
71
|
+
await sensor.powerUp(); // Power up, () → void
|
|
72
|
+
// sets CTRL_REG1.PD
|
|
73
|
+
await sensor.onInterrupt((status) => console.log('DRDY status', status)); // Subscribe to data-ready, (callback, intPin=null) → void
|
|
74
|
+
// edge on the pin or a polling timer
|
|
75
|
+
await sleep(2000);
|
|
76
|
+
await sensor.offInterrupt(); // Unsubscribe, () → void
|
|
77
|
+
// disables the DRDY output
|
|
78
|
+
await sensor.reboot(); // Reload trimming, () → void
|
|
79
|
+
// sets BOOT, waits, re-reads the calibration
|
|
80
|
+
connection.close();
|
|
81
|
+
}
|
|
82
|
+
|
|
83
|
+
main().catch(err => { console.error(err); process.exit(1); });
|
|
@@ -0,0 +1,94 @@
|
|
|
1
|
+
'use strict';
|
|
2
|
+
|
|
3
|
+
const { I2CConnection } = require('../../../src/connection/i2c');
|
|
4
|
+
const { HTS221Full } = require('../../../src/chips/humidity/hts221');
|
|
5
|
+
|
|
6
|
+
const I2C_BUS = parseInt(process.env.I2C_BUS || '1', 10);
|
|
7
|
+
const I2C_ADDR = parseInt(process.env.I2C_ADDR || '0x5F', 16);
|
|
8
|
+
const sleep = (ms) => new Promise(r => setTimeout(r, ms));
|
|
9
|
+
|
|
10
|
+
const connection = new I2CConnection(I2C_BUS, I2C_ADDR); // Create I²C connection, (bus=1, addr=0x5F) → Connection
|
|
11
|
+
const sensor = new HTS221Full(connection); // Create HTS221 driver, (connection) → void
|
|
12
|
+
|
|
13
|
+
async function main() {
|
|
14
|
+
await sensor.init(); // Read calibration and start one-shot mode, () → void
|
|
15
|
+
|
|
16
|
+
// --- Identify the chip and show the factory calibration ---
|
|
17
|
+
// Every HTS221 stores its own two-point calibration; the driver read it
|
|
18
|
+
// during init() and uses it for every conversion.
|
|
19
|
+
console.log('who am i 0x' + (await sensor.whoAmI()).toString(16)); // Read WHO_AM_I, () → number (0xBC)
|
|
20
|
+
console.log('calibration', await sensor.readCalibration()); // Read calibration, () → object
|
|
21
|
+
|
|
22
|
+
// --- One-shot hygrometer: 10 readings, 2 s apart ---
|
|
23
|
+
// Each read() starts a conversion; the dew point shows what the pair
|
|
24
|
+
// means for condensation risk.
|
|
25
|
+
for (let i = 0; i < 10; i++) {
|
|
26
|
+
const m = await sensor.read(); // Read temperature and humidity, () → {temperature_c °C, humidity_pct %rH}
|
|
27
|
+
const dew = await sensor.dewPoint(); // Compute dew point, () → number °C
|
|
28
|
+
console.log(m.temperature_c.toFixed(2) + ' C ' + m.humidity_pct.toFixed(1) + ' %rH dew ' + dew.toFixed(2) + ' C');
|
|
29
|
+
console.log('raw', await sensor.readRawHumidity(), await sensor.readRawTemperature()); // Read raw outputs, () → number
|
|
30
|
+
console.log('h', (await sensor.readHumidity()).toFixed(1), 't', (await sensor.readTemperature()).toFixed(2)); // Read single values, () → number
|
|
31
|
+
await sleep(2000);
|
|
32
|
+
}
|
|
33
|
+
|
|
34
|
+
// --- Continuous sampling at 1 Hz and 12.5 Hz ---
|
|
35
|
+
// dataReady() paces the loop; the sample count per second follows the rate.
|
|
36
|
+
await sensor.setBlockDataUpdate(true); // Set block data update, (enabled) → void
|
|
37
|
+
for (const hz of [1, 12.5]) {
|
|
38
|
+
await sensor.setOutputDataRate(hz); // Set output data rate, (hz 0|1|7|12.5) → void
|
|
39
|
+
console.log('rate', await sensor.getOutputDataRate(), 'Hz'); // Get output data rate, () → number Hz
|
|
40
|
+
let count = 0;
|
|
41
|
+
const end = Date.now() + 3000;
|
|
42
|
+
while (Date.now() < end) {
|
|
43
|
+
if (await sensor.dataReady()) { // Check data available, () → boolean
|
|
44
|
+
await sensor.readContinuous(); // Read latest sample, () → object
|
|
45
|
+
count++;
|
|
46
|
+
}
|
|
47
|
+
await sleep(5);
|
|
48
|
+
}
|
|
49
|
+
console.log((count / 3).toFixed(1) + ' samples/s');
|
|
50
|
+
}
|
|
51
|
+
await sensor.setOutputDataRate(0); // Set output data rate, (hz 0|1|7|12.5) → void
|
|
52
|
+
|
|
53
|
+
// --- Noise at lowest and highest averaging ---
|
|
54
|
+
// Ten one-shot samples each; the spread of the raw humidity shrinks as
|
|
55
|
+
// the averaging grows.
|
|
56
|
+
for (const [t, h] of [[2, 4], [256, 512]]) {
|
|
57
|
+
await sensor.setAveraging(t, h); // Set averaging, (temperatureSamples, humiditySamples) → void
|
|
58
|
+
console.log('averaging', await sensor.getAveraging()); // Get averaging, () → [number, number]
|
|
59
|
+
const raws = [];
|
|
60
|
+
for (let i = 0; i < 10; i++) raws.push(await sensor.readRawHumidity()); // Read raw humidity, () → number
|
|
61
|
+
console.log('raw humidity spread', Math.max(...raws) - Math.min(...raws));
|
|
62
|
+
}
|
|
63
|
+
await sensor.setAveraging(16, 32); // Set averaging, (temperatureSamples, humiditySamples) → void
|
|
64
|
+
|
|
65
|
+
// --- Heater: drive off condensation for 10 s ---
|
|
66
|
+
// Humidity falls and temperature rises while the heater runs; measure
|
|
67
|
+
// before and after, never during, then let the sensor cool.
|
|
68
|
+
const before = await sensor.read(); // Read temperature and humidity, () → object
|
|
69
|
+
await sensor.setHeater(true); // Switch the heater, (on) → void
|
|
70
|
+
console.log('heater on:', await sensor.isHeaterOn()); // Heater state, () → boolean
|
|
71
|
+
await sleep(10000);
|
|
72
|
+
await sensor.setHeater(false); // Switch the heater, (on) → void
|
|
73
|
+
const after = await sensor.read(); // Read temperature and humidity, () → object
|
|
74
|
+
console.log('before', before, 'after', after);
|
|
75
|
+
|
|
76
|
+
// --- Data-ready notification for 5 s ---
|
|
77
|
+
// Uses the DRDY pin when the connection has one, otherwise a polling timer.
|
|
78
|
+
await sensor.configureDrdy(true, true, false); // Configure DRDY pin, (enabled, activeHigh=true, openDrain=false) → void
|
|
79
|
+
await sensor.setOutputDataRate(1); // Set output data rate, (hz 0|1|7|12.5) → void
|
|
80
|
+
await sensor.onInterrupt((status) => console.log('DRDY status', status)); // Subscribe to data-ready, (callback, intPin=null) → void
|
|
81
|
+
await sleep(5000);
|
|
82
|
+
await sensor.offInterrupt(); // Unsubscribe, () → void
|
|
83
|
+
console.log('poll', await sensor.pollInterrupt(), 'status', await sensor.status()); // Poll interrupt status, () → number
|
|
84
|
+
await sensor.setOutputDataRate(0);
|
|
85
|
+
|
|
86
|
+
// --- Power cycle and reload ---
|
|
87
|
+
await sensor.powerDown(); // Power down, () → void
|
|
88
|
+
await sensor.powerUp(); // Power up, () → void
|
|
89
|
+
await sensor.reboot(); // Reload trimming, () → void
|
|
90
|
+
console.log('done:', (await sensor.read()).temperature_c.toFixed(2), 'C');
|
|
91
|
+
connection.close();
|
|
92
|
+
}
|
|
93
|
+
|
|
94
|
+
main().catch(err => { console.error(err); process.exit(1); });
|
|
@@ -0,0 +1,22 @@
|
|
|
1
|
+
'use strict';
|
|
2
|
+
|
|
3
|
+
const { I2CConnection } = require('../../../src/connection/i2c');
|
|
4
|
+
const { HTS221Minimal } = require('../../../src/chips/humidity/hts221');
|
|
5
|
+
|
|
6
|
+
const I2C_BUS = parseInt(process.env.I2C_BUS || '1', 10);
|
|
7
|
+
const I2C_ADDR = parseInt(process.env.I2C_ADDR || '0x5F', 16);
|
|
8
|
+
const sleep = (ms) => new Promise(r => setTimeout(r, ms));
|
|
9
|
+
|
|
10
|
+
const connection = new I2CConnection(I2C_BUS, I2C_ADDR); // Create I²C connection, (bus=1, addr=0x5F) → Connection
|
|
11
|
+
const sensor = new HTS221Minimal(connection); // Create HTS221 driver, (connection) → void
|
|
12
|
+
|
|
13
|
+
async function main() {
|
|
14
|
+
await sensor.init(); // Read calibration and start one-shot mode, () → void
|
|
15
|
+
while (true) {
|
|
16
|
+
const m = await sensor.read(); // Read temperature and humidity, () → {temperature_c: number °C, humidity_pct: number %rH}
|
|
17
|
+
console.log('%s C, %s %%rH', m.temperature_c.toFixed(2), m.humidity_pct.toFixed(1));
|
|
18
|
+
await sleep(2000);
|
|
19
|
+
}
|
|
20
|
+
}
|
|
21
|
+
|
|
22
|
+
main().catch(err => { console.error(err); process.exit(1); });
|
|
@@ -0,0 +1,50 @@
|
|
|
1
|
+
'use strict';
|
|
2
|
+
|
|
3
|
+
const { I2CConnection } = require('../../../src/connection/i2c');
|
|
4
|
+
const { HTU31DFull } = require('../../../src/chips/humidity/htu31d');
|
|
5
|
+
|
|
6
|
+
const I2C_BUS = parseInt(process.env.I2C_BUS || '1', 10);
|
|
7
|
+
const I2C_ADDR = parseInt(process.env.I2C_ADDR || '0x40', 16);
|
|
8
|
+
const sleep = (ms) => new Promise(r => setTimeout(r, ms));
|
|
9
|
+
|
|
10
|
+
const connection = new I2CConnection(I2C_BUS, I2C_ADDR); // Create I²C connection, (bus=1, addr=0x40) → Connection
|
|
11
|
+
const sensor = new HTU31DFull(connection); // Create HTU31D driver, (connection) → void
|
|
12
|
+
|
|
13
|
+
async function main() {
|
|
14
|
+
await sensor.init(); // Soft reset, () → void
|
|
15
|
+
// 0x1E, waits 15 ms; highest resolution, heater off
|
|
16
|
+
const m = await sensor.read(); // Read temperature and humidity, () → {temperature_c: number °C, humidity_pct: number %RH}
|
|
17
|
+
// OSR 3 / 3 by default, both CRCs verified, humidity clamped 0-100
|
|
18
|
+
console.log(m);
|
|
19
|
+
console.log(await sensor.readHumidity()); // Read humidity only, () → number %RH
|
|
20
|
+
console.log(await sensor.readTemperature()); // Read temperature only, () → number °C
|
|
21
|
+
console.log(await sensor.readRaw()); // Read raw codes, () → [t_raw, rh_raw]
|
|
22
|
+
// 16-bit unsigned
|
|
23
|
+
|
|
24
|
+
sensor.setResolution(1, 2); // Set oversampling, (osrRh 0-3, osrT 0-3) → void
|
|
25
|
+
// higher OSR = finer resolution, longer conversion
|
|
26
|
+
console.log(sensor.getResolution()); // Get oversampling, () → [osrRh, osrT]
|
|
27
|
+
console.log(sensor.conversionTime()); // Typical conversion time, () → number s
|
|
28
|
+
sensor.setResolution(3, 3);
|
|
29
|
+
|
|
30
|
+
await sensor.startConversion(); // Start a conversion, () → void
|
|
31
|
+
// non-blocking; wait conversionTime() before reading
|
|
32
|
+
await sleep(30);
|
|
33
|
+
console.log(await sensor.readResult()); // Read last conversion result, () → {temperature_c, humidity_pct}
|
|
34
|
+
|
|
35
|
+
await sensor.setHeater(true); // Switch the heater, (on) → void
|
|
36
|
+
// 0x04; readings drift while the heater runs
|
|
37
|
+
console.log(await sensor.isHeaterOn()); // Heater state, () → boolean
|
|
38
|
+
await sensor.setHeater(false);
|
|
39
|
+
console.log((await sensor.diagnostic()).toString(16)); // Read the diagnostic byte, () → number
|
|
40
|
+
console.log(await sensor.diagnosticFlags()); // Named diagnostic flags, () → object
|
|
41
|
+
console.log((await sensor.serialNumber()).toString(16)); // Read the serial number, () → number
|
|
42
|
+
// 24-bit, CRC verified
|
|
43
|
+
console.log(await sensor.dewPoint()); // Compute dew point, () → number °C
|
|
44
|
+
// one measurement, Magnus formula
|
|
45
|
+
await sensor.softReset(); // Soft reset, () → void
|
|
46
|
+
// 0x1E, waits 15 ms; heater off, OSR 3 / 3
|
|
47
|
+
connection.close();
|
|
48
|
+
}
|
|
49
|
+
|
|
50
|
+
main().catch(err => { console.error(err); process.exit(1); });
|
|
@@ -0,0 +1,65 @@
|
|
|
1
|
+
'use strict';
|
|
2
|
+
|
|
3
|
+
const { I2CConnection } = require('../../../src/connection/i2c');
|
|
4
|
+
const { HTU31DFull } = require('../../../src/chips/humidity/htu31d');
|
|
5
|
+
|
|
6
|
+
const I2C_BUS = parseInt(process.env.I2C_BUS || '1', 10);
|
|
7
|
+
const I2C_ADDR = parseInt(process.env.I2C_ADDR || '0x40', 16);
|
|
8
|
+
const sleep = (ms) => new Promise(r => setTimeout(r, ms));
|
|
9
|
+
|
|
10
|
+
const connection = new I2CConnection(I2C_BUS, I2C_ADDR); // Create I²C connection, (bus=1, addr=0x40) → Connection
|
|
11
|
+
const sensor = new HTU31DFull(connection); // Create HTU31D driver, (connection) → void
|
|
12
|
+
|
|
13
|
+
async function main() {
|
|
14
|
+
await sensor.init(); // Soft reset, () → void
|
|
15
|
+
|
|
16
|
+
// --- Identify the chip and check its health ---
|
|
17
|
+
// The serial number is unique per device; the diagnostic flags report NVM
|
|
18
|
+
// and out-of-range errors.
|
|
19
|
+
console.log('serial 0x' + (await sensor.serialNumber()).toString(16)); // Read the serial number, () → number
|
|
20
|
+
console.log('diagnostic', await sensor.diagnosticFlags()); // Named diagnostic flags, () → object
|
|
21
|
+
|
|
22
|
+
// --- Condensation-aware hygrometer: 15 readings, 2 s apart ---
|
|
23
|
+
// The dew point shows how close the air is to condensing on a surface.
|
|
24
|
+
for (let i = 0; i < 15; i++) {
|
|
25
|
+
const m = await sensor.read(); // Read temperature and humidity, () → {temperature_c °C, humidity_pct %RH}
|
|
26
|
+
const dew = await sensor.dewPoint(); // Compute dew point, () → number °C
|
|
27
|
+
console.log('%s C %s %%RH dew %s C', m.temperature_c.toFixed(2), m.humidity_pct.toFixed(1), dew.toFixed(2));
|
|
28
|
+
console.log('h', (await sensor.readHumidity()).toFixed(1), 't', (await sensor.readTemperature()).toFixed(2), 'raw', await sensor.readRaw()); // Read single values and raw codes
|
|
29
|
+
await sleep(2000);
|
|
30
|
+
}
|
|
31
|
+
|
|
32
|
+
// --- Compare the four oversampling settings ---
|
|
33
|
+
// Higher OSR gives finer resolution at the cost of a longer conversion.
|
|
34
|
+
for (let osr = 0; osr < 4; osr++) {
|
|
35
|
+
sensor.setResolution(osr, osr); // Set oversampling, (osrRh 0-3, osrT 0-3) → void
|
|
36
|
+
const start = Date.now();
|
|
37
|
+
const m = await sensor.read(); // Read temperature and humidity, () → {temperature_c, humidity_pct}
|
|
38
|
+
console.log('OSR', sensor.getResolution(), 'typ', (sensor.conversionTime() * 1000).toFixed(2), 'ms', 'read', Date.now() - start, 'ms', m); // Get oversampling and typical conversion time
|
|
39
|
+
}
|
|
40
|
+
sensor.setResolution(3, 3);
|
|
41
|
+
|
|
42
|
+
// --- Heater: drive off condensation for 10 s ---
|
|
43
|
+
// Humidity falls and temperature rises while the heater runs; measure
|
|
44
|
+
// before and after, never during, then let the sensor cool.
|
|
45
|
+
const before = await sensor.read(); // Read temperature and humidity, () → {temperature_c, humidity_pct}
|
|
46
|
+
await sensor.setHeater(true); // Switch the heater, (on) → void
|
|
47
|
+
console.log('heater on:', await sensor.isHeaterOn(), (await sensor.diagnostic()).toString(16)); // Heater state and diagnostic byte, () → boolean / number
|
|
48
|
+
await sleep(10000);
|
|
49
|
+
await sensor.setHeater(false); // Switch the heater, (on) → void
|
|
50
|
+
const after = await sensor.read(); // Read temperature and humidity, () → {temperature_c, humidity_pct}
|
|
51
|
+
console.log('before', before, 'after', after);
|
|
52
|
+
|
|
53
|
+
// --- Non-blocking conversion ---
|
|
54
|
+
// Start the conversion, do other work, then collect the result.
|
|
55
|
+
await sensor.startConversion(); // Start a conversion, () → void
|
|
56
|
+
await sleep(sensor.conversionTime() * 1250);
|
|
57
|
+
console.log('result', await sensor.readResult()); // Read last conversion result, () → {temperature_c, humidity_pct}
|
|
58
|
+
|
|
59
|
+
// --- Reset ---
|
|
60
|
+
await sensor.softReset(); // Soft reset, () → void
|
|
61
|
+
console.log('done: %s C', (await sensor.read()).temperature_c.toFixed(2));
|
|
62
|
+
connection.close();
|
|
63
|
+
}
|
|
64
|
+
|
|
65
|
+
main().catch(err => { console.error(err); process.exit(1); });
|
|
@@ -0,0 +1,22 @@
|
|
|
1
|
+
'use strict';
|
|
2
|
+
|
|
3
|
+
const { I2CConnection } = require('../../../src/connection/i2c');
|
|
4
|
+
const { HTU31DMinimal } = require('../../../src/chips/humidity/htu31d');
|
|
5
|
+
|
|
6
|
+
const I2C_BUS = parseInt(process.env.I2C_BUS || '1', 10);
|
|
7
|
+
const I2C_ADDR = parseInt(process.env.I2C_ADDR || '0x40', 16);
|
|
8
|
+
const sleep = (ms) => new Promise(r => setTimeout(r, ms));
|
|
9
|
+
|
|
10
|
+
const connection = new I2CConnection(I2C_BUS, I2C_ADDR); // Create I²C connection, (bus=1, addr=0x40) → Connection
|
|
11
|
+
const sensor = new HTU31DMinimal(connection); // Create HTU31D driver, (connection) → void
|
|
12
|
+
|
|
13
|
+
async function main() {
|
|
14
|
+
await sensor.init(); // Soft reset, () → void
|
|
15
|
+
while (true) {
|
|
16
|
+
const m = await sensor.read(); // Read temperature and humidity, () → {temperature_c: number °C, humidity_pct: number %RH}
|
|
17
|
+
console.log('%s C, %s %%RH', m.temperature_c.toFixed(2), m.humidity_pct.toFixed(1));
|
|
18
|
+
await sleep(2000);
|
|
19
|
+
}
|
|
20
|
+
}
|
|
21
|
+
|
|
22
|
+
main().catch(err => { console.error(err); process.exit(1); });
|
|
@@ -0,0 +1,48 @@
|
|
|
1
|
+
'use strict';
|
|
2
|
+
|
|
3
|
+
const { I2CConnection } = require('../../../src/connection/i2c');
|
|
4
|
+
const { SHTC3Full } = require('../../../src/chips/humidity/shtc3');
|
|
5
|
+
|
|
6
|
+
const I2C_BUS = parseInt(process.env.I2C_BUS || '1', 10);
|
|
7
|
+
const I2C_ADDR = parseInt(process.env.I2C_ADDR || '0x70', 16);
|
|
8
|
+
const sleep = (ms) => new Promise(r => setTimeout(r, ms));
|
|
9
|
+
|
|
10
|
+
const connection = new I2CConnection(I2C_BUS, I2C_ADDR); // Create I²C connection, (bus=1, addr=0x70) → Connection
|
|
11
|
+
const sensor = new SHTC3Full(connection); // Create SHTC3 driver, (connection) → void
|
|
12
|
+
|
|
13
|
+
async function main() {
|
|
14
|
+
await sensor.init(); // Soft reset and ID check, () → void
|
|
15
|
+
|
|
16
|
+
console.log(await sensor.read()); // Read temperature and humidity, () → {temperature_c: number °C, humidity_pct: number %RH}
|
|
17
|
+
// normal mode, both CRCs verified, humidity clamped 0-100
|
|
18
|
+
console.log(await sensor.readHumidity()); // Read humidity only, () → number %RH
|
|
19
|
+
console.log(await sensor.readTemperature()); // Read temperature only, () → number °C
|
|
20
|
+
console.log(await sensor.readRaw()); // Read raw codes, () → [number, number]
|
|
21
|
+
// [raw_temperature, raw_humidity], 16-bit
|
|
22
|
+
console.log((await sensor.readId()).toString(16)); // Read the ID word, () → number
|
|
23
|
+
// (id & 0x083F) === 0x0807 for the SHTC3
|
|
24
|
+
|
|
25
|
+
sensor.setLowPower(true); // Select low-power mode, (on) → void
|
|
26
|
+
// 0.7 ms measurement, slightly noisier
|
|
27
|
+
console.log(await sensor.read());
|
|
28
|
+
sensor.setLowPower(false);
|
|
29
|
+
|
|
30
|
+
sensor.setClockStretching(true); // Select clock stretching, (on) → void
|
|
31
|
+
// needs a controller that tolerates SCL held low
|
|
32
|
+
console.log(await sensor.read());
|
|
33
|
+
sensor.setClockStretching(false);
|
|
34
|
+
|
|
35
|
+
sensor.setSleepBetween(false); // Sleep after every read?, (on) → void
|
|
36
|
+
// off keeps the sensor idle (higher supply current)
|
|
37
|
+
console.log(await sensor.read());
|
|
38
|
+
sensor.setSleepBetween(true);
|
|
39
|
+
await sensor.wake(); // Wake-up command, () → void
|
|
40
|
+
await sensor.sleep(); // Sleep command, () → void
|
|
41
|
+
console.log(await sensor.dewPoint()); // Compute dew point, () → number °C
|
|
42
|
+
// one measurement, Magnus formula
|
|
43
|
+
await sensor.softReset(); // Soft reset, () → void
|
|
44
|
+
// 0x805D, leaves the sensor idle
|
|
45
|
+
connection.close();
|
|
46
|
+
}
|
|
47
|
+
|
|
48
|
+
main().catch(err => { console.error(err); process.exit(1); });
|
|
@@ -0,0 +1,45 @@
|
|
|
1
|
+
'use strict';
|
|
2
|
+
|
|
3
|
+
const { I2CConnection } = require('../../../src/connection/i2c');
|
|
4
|
+
const { SHTC3Full } = require('../../../src/chips/humidity/shtc3');
|
|
5
|
+
|
|
6
|
+
const I2C_BUS = parseInt(process.env.I2C_BUS || '1', 10);
|
|
7
|
+
const I2C_ADDR = parseInt(process.env.I2C_ADDR || '0x70', 16);
|
|
8
|
+
const sleep = (ms) => new Promise(r => setTimeout(r, ms));
|
|
9
|
+
|
|
10
|
+
const connection = new I2CConnection(I2C_BUS, I2C_ADDR); // Create I²C connection, (bus=1, addr=0x70) → Connection
|
|
11
|
+
const sensor = new SHTC3Full(connection); // Create SHTC3 driver, (connection) → void
|
|
12
|
+
|
|
13
|
+
async function main() {
|
|
14
|
+
await sensor.init(); // Soft reset and ID check, () → void
|
|
15
|
+
|
|
16
|
+
// --- Identify the chip ---
|
|
17
|
+
// The ID word carries the SHTC3 product code in bits 11 and 5:0.
|
|
18
|
+
console.log('id 0x' + (await sensor.readId()).toString(16)); // Read the ID word, () → number
|
|
19
|
+
|
|
20
|
+
// --- Battery-friendly climate logger: 6 readings, 10 s apart ---
|
|
21
|
+
// The sensor sleeps (0.3 uA) between the readings; every read wakes it.
|
|
22
|
+
for (let i = 0; i < 6; i++) {
|
|
23
|
+
const m = await sensor.read(); // Read temperature and humidity, () → {temperature_c: number °C, humidity_pct: number %RH}
|
|
24
|
+
console.log('%s C %s %%RH', m.temperature_c.toFixed(2), m.humidity_pct.toFixed(1));
|
|
25
|
+
await sleep(10000);
|
|
26
|
+
}
|
|
27
|
+
|
|
28
|
+
// --- Compare normal and low-power mode ---
|
|
29
|
+
// Low power measures in 0.7 ms instead of 10.8 ms at slightly higher noise.
|
|
30
|
+
for (const low of [false, true]) {
|
|
31
|
+
sensor.setLowPower(low); // Select low-power mode, (on) → void
|
|
32
|
+
const start = Date.now();
|
|
33
|
+
const m = await sensor.read(); // Read temperature and humidity, () → {temperature_c: number °C, humidity_pct: number %RH}
|
|
34
|
+
console.log(low ? 'low power' : 'normal ', (Date.now() - start) + ' ms', m);
|
|
35
|
+
}
|
|
36
|
+
sensor.setLowPower(false);
|
|
37
|
+
|
|
38
|
+
// --- Dew point and raw words, then finish asleep ---
|
|
39
|
+
console.log('dew point', (await sensor.dewPoint()).toFixed(2), 'C'); // Compute dew point, () → number °C
|
|
40
|
+
console.log('raw', await sensor.readRaw()); // Read raw codes, () → [number, number]
|
|
41
|
+
await sensor.sleep(); // Sleep command, () → void
|
|
42
|
+
connection.close();
|
|
43
|
+
}
|
|
44
|
+
|
|
45
|
+
main().catch(err => { console.error(err); process.exit(1); });
|