oltc-selector 2.3.1 → 2.4.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/README.md +32 -4
- package/bin/oltc.js +37 -33
- package/package.json +1 -1
package/README.md
CHANGED
|
@@ -6,7 +6,7 @@ The type is a starting point. Get engineering confirmation before an order.
|
|
|
6
6
|
|
|
7
7
|
## CLI
|
|
8
8
|
|
|
9
|
-
You do not need to clone this repository.
|
|
9
|
+
You do not need to clone this repository. Node.js 20 or later is needed.
|
|
10
10
|
|
|
11
11
|
```bash
|
|
12
12
|
npm i -g oltc-selector
|
|
@@ -15,8 +15,14 @@ oltc --iu 350 --um 40.5 --conn D --reg W --pm 8
|
|
|
15
15
|
# CV2III-350D/40.5-10193W
|
|
16
16
|
|
|
17
17
|
oltc --octc --iu 800 --um 72.5 --conn D --series II --contact 6x5
|
|
18
|
+
# WSLII-800D/72.5-6x5A
|
|
19
|
+
|
|
18
20
|
oltc --iu 600 --um 72.5 --conn Y --reg W --pm 8 --structure combined
|
|
21
|
+
# CM2III-600Y/72.5B-10193W
|
|
22
|
+
|
|
19
23
|
oltc --mva 25 --kv 110 --tap neutral --reg W --pm 8
|
|
24
|
+
# CV2III-350Y/72.5-10193W
|
|
25
|
+
|
|
20
26
|
oltc --mva 16 --kv 22 --tap line --winding star
|
|
21
27
|
# CV2III-600D/40.5-10193W
|
|
22
28
|
|
|
@@ -29,20 +35,26 @@ oltc --line "220/110/35kV-125MVA 225±8x1,25%/115/35kV YNa0d11"
|
|
|
29
35
|
# 3xCM2I-500/252D-10193W, plus the type at Um 126 / 170 / 252
|
|
30
36
|
```
|
|
31
37
|
|
|
38
|
+
Output is in Chinese by default; `--lang en` gives English. Every run asks npm for a newer version and prints a notice when there is one. Nothing is installed for you.
|
|
39
|
+
|
|
40
|
+
<details>
|
|
41
|
+
<summary><b>All flags</b></summary>
|
|
42
|
+
|
|
43
|
+
<br>
|
|
44
|
+
|
|
32
45
|
| Flag | Meaning | Default |
|
|
33
46
|
|------|---------|---------|
|
|
34
47
|
| `--line "text"` | Tender line: MVA, kV ratio with ±N×x%, vector group. Flags given beside it win. | |
|
|
35
48
|
| `--iu` / `--imax` | Max through-current Imax (A). **No** safety factor. | required unless `--mva` |
|
|
36
|
-
| `--mva` `--kv` | Transformer MVA + tap-side kV → Imax (min tap + `--k`). With `--iu`, `--kv` alone sets the winding voltage for the 220/330 kV
|
|
49
|
+
| `--mva` `--kv` | Transformer MVA + tap-side kV → Imax (min tap + `--k`). With `--iu`, `--kv` alone sets the winding voltage for the 220/330 kV rules | |
|
|
37
50
|
| `--k` | Safety factor ≥ 1, **capacity path only** | 1.0 |
|
|
38
51
|
| `--step-pct` | Step as a percent (1.25 means 1.25 %), capacity path only | 1.25 |
|
|
39
52
|
| `--os-imax` | Capacity path: the Imax the OS or maker states at the lowest tap (`--imax` beside `--mva` means this) | |
|
|
40
53
|
| `--kind two\|auto` | Transformer kind (`--auto` = `--kind auto`) | two-winding |
|
|
41
|
-
| `--tap` | Where the OLTC sits: `neutral` / `line` (two-winding), `junction` / `mv-line` (autotransformer). Sets current, Ust and Um. | neutral |
|
|
54
|
+
| `--tap` | Where the OLTC sits: `neutral` / `line` (two-winding), `junction` / `mv-line` (autotransformer). Sets current, Ust and Um. | neutral; junction with `--kind auto` |
|
|
42
55
|
| `--winding star\|delta` | Tapped winding connection (two-winding) | star |
|
|
43
56
|
| `--hv` `--mv` | Autotransformer HV / MV rated kV | |
|
|
44
57
|
| `--earth-um` | OLTC insulation to earth from the OS; overrides the rule | |
|
|
45
|
-
| `--market` | Buyer's country for a neutral's assumed Um. Rules exist for `IT` and `TR`; another code prints a note and is not used | |
|
|
46
58
|
| `--across-li` `--across-ac` | Stated LI / AC withstand across the tap winding (kV): sets the selector grade B/C/D/DE | |
|
|
47
59
|
| `--um` | Equipment Um (kV) | derived from `--kv` if omitted |
|
|
48
60
|
| `--ust` | Step voltage (V) | 0, or derived on MVA path |
|
|
@@ -72,6 +84,13 @@ Every flag with a value also takes `--flag=value`. A flag that cannot take effec
|
|
|
72
84
|
|
|
73
85
|
**Exit code:** `0` a type was found (or help / version); `1` no type, or bad input.
|
|
74
86
|
|
|
87
|
+
</details>
|
|
88
|
+
|
|
89
|
+
<details>
|
|
90
|
+
<summary><b><code>--json</code> keys</b></summary>
|
|
91
|
+
|
|
92
|
+
<br>
|
|
93
|
+
|
|
75
94
|
**`--json`** prints one object. For bad input (a flag that cannot be read) the object holds only `ok`, `version`, `model` and `errors`.
|
|
76
95
|
|
|
77
96
|
| Key | Holds |
|
|
@@ -87,8 +106,15 @@ Every flag with a value also takes `--flag=value`. A flag that cannot take effec
|
|
|
87
106
|
| `assumptions` | Every default that was applied, as text |
|
|
88
107
|
| `errors` | Why there is no type |
|
|
89
108
|
|
|
109
|
+
</details>
|
|
110
|
+
|
|
90
111
|
## Selection rules
|
|
91
112
|
|
|
113
|
+
<details>
|
|
114
|
+
<summary><b>The eleven rules the engine follows</b></summary>
|
|
115
|
+
|
|
116
|
+
<br>
|
|
117
|
+
|
|
92
118
|
1. **Minimum-adequate, not SHZV-by-default.** Rank **CV2 → CM2 → SHZV → SDZV → SHZVG**. SDZV (dual-break, Ust 6000 V) only when SHZV step voltage or step capacity is short. Prefer one three-phase unit over `3×` singles when a brochure III type exists.
|
|
93
119
|
2. **OLTC existence comes from brochure / catalogue axes** (`lib/catalog.ts`), **not price-list Y/D twins**. A 2025 list row that prices `CM2III-…D` the same as Y does **not** make `CM2III-…D` a type.
|
|
94
120
|
3. **No CV2-500.** CV2 III currents are 350 and 600 only.
|
|
@@ -100,3 +126,5 @@ Every flag with a value also takes `--flag=value`. A flag that cannot take effec
|
|
|
100
126
|
9. **Um is set where the tap changer sits** (`lib/transformer.ts`). Line end: the winding system's class (132 kV → 145, 220 kV → 252). Neutral: the full class up to 72.5; above that 72.5 is assumed and flagged. Autotransformer: the HV system's class, combined types only (no CV / CV2 / SV).
|
|
101
127
|
10. **Tapped windings on 220 kV class and above take combined types only.** 2025–2026 OS: 67 of 67 were CM / CM2 / SHZV.
|
|
102
128
|
11. **An open Um is shown as a choice.** Star points above 72.5 and autotransformers list the type at each Um class; the tender's insulation picks one (`--earth-um`, or a row on the card).
|
|
129
|
+
|
|
130
|
+
</details>
|
package/bin/oltc.js
CHANGED
|
@@ -1,7 +1,7 @@
|
|
|
1
1
|
#!/usr/bin/env node
|
|
2
2
|
|
|
3
3
|
// lib/appVersion.ts
|
|
4
|
-
var APP_VERSION = "2.
|
|
4
|
+
var APP_VERSION = "2.4.0";
|
|
5
5
|
|
|
6
6
|
// lib/decimal.ts
|
|
7
7
|
var GROUPED = /^\d{1,3}([,,]\d{3})+$/;
|
|
@@ -2869,21 +2869,21 @@ function deriveDuty(spec) {
|
|
|
2869
2869
|
);
|
|
2870
2870
|
}
|
|
2871
2871
|
if (umRule === "neutral_full" && umAssumed) {
|
|
2872
|
-
cautionsZh.push("35 kV \u7EA7\u4E2D\u6027\u70B9\u5148\u6309 Um 40.5 kV \u9009\uFF1B\u4E0D\u5C11\u9879\u76EE\u8981\u6C42 72.5\uFF0C\u4EE5\u8BA2\u8D27\u89C4\u8303\
|
|
2872
|
+
cautionsZh.push("35 kV \u7EA7\u4E2D\u6027\u70B9\u5148\u6309 Um 40.5 kV \u9009\uFF1B\u4E0D\u5C11\u9879\u76EE\u8981\u6C42 72.5\uFF0C\u4EE5\u8BA2\u8D27\u89C4\u8303\u4E3A\u51C6\u3002CM/CM2/SHZV \u6700\u4F4E\u5C31\u662F 72.5\u3002");
|
|
2873
2873
|
cautionsEn.push("35 kV-class neutral sized at Um 40.5 kV; many projects specify 72.5; the order specification (OS) decides. CM/CM2/SHZV start at 72.5.");
|
|
2874
2874
|
}
|
|
2875
2875
|
if (umRule === "neutral_assumed") {
|
|
2876
2876
|
if (neutralMarket === "IT") {
|
|
2877
|
-
cautionsZh.push(`\u610F\u5927\u5229\u4E2D\u6027\u70B9\u5148\u6309\u7EBF\u7AEF\u7B49\u7EA7 Um ${umKv} kV \u9009\uFF08\u90E8\u5206\u9879\u76EE\u7528 72.5\uFF09\uFF0C\u4EE5\u8BA2\u8D27\u89C4\u8303\
|
|
2877
|
+
cautionsZh.push(`\u610F\u5927\u5229\u4E2D\u6027\u70B9\u5148\u6309\u7EBF\u7AEF\u7B49\u7EA7 Um ${umKv} kV \u9009\uFF08\u90E8\u5206\u9879\u76EE\u7528 72.5\uFF09\uFF0C\u4EE5\u8BA2\u8D27\u89C4\u8303\u4E3A\u51C6\u3002`);
|
|
2878
2878
|
cautionsEn.push(`Italy: neutral sized at the line class, Um ${umKv} kV (some projects use 72.5); the order specification (OS) decides.`);
|
|
2879
2879
|
} else if (neutralMarket === "TR") {
|
|
2880
|
-
cautionsZh.push(`\u571F\u8033\u5176 220 kV \u7EA7\u53CA\u4EE5\u4E0A\u4E2D\u6027\u70B9\u5148\u6309 Um ${umKv} kV \u9009\uFF08\u901A\u5E38 126 \u6216 170\uFF0C\u4E0D\u7528 72.5\uFF09\uFF0C\u4EE5\u8BA2\u8D27\u89C4\u8303\
|
|
2880
|
+
cautionsZh.push(`\u571F\u8033\u5176 220 kV \u7EA7\u53CA\u4EE5\u4E0A\u4E2D\u6027\u70B9\u5148\u6309 Um ${umKv} kV \u9009\uFF08\u901A\u5E38 126 \u6216 170\uFF0C\u4E0D\u7528 72.5\uFF09\uFF0C\u4EE5\u8BA2\u8D27\u89C4\u8303\u4E3A\u51C6\u3002`);
|
|
2881
2881
|
cautionsEn.push(`Turkey: 220 kV-class and above neutral sized at Um ${umKv} kV (126 or 170 is usual, not 72.5); the order specification (OS) decides.`);
|
|
2882
2882
|
} else if (umKv === NEUTRAL_400KV_UM) {
|
|
2883
|
-
cautionsZh.push(`400 kV \u7EA7\u7ED5\u7EC4\u4E2D\u6027\u70B9\u5148\u6309 Um ${umKv} kV \u9009\uFF08\u571F\u8033\u5176\u3001\u8461\u8404\u7259\u5E38\u7528 126\uFF1B\u5DF4\u897F 440/500 kV \u5E38\u7528 72.5\uFF09\uFF0C\u4EE5\u8BA2\u8D27\u89C4\u8303\
|
|
2883
|
+
cautionsZh.push(`400 kV \u7EA7\u7ED5\u7EC4\u4E2D\u6027\u70B9\u5148\u6309 Um ${umKv} kV \u9009\uFF08\u571F\u8033\u5176\u3001\u8461\u8404\u7259\u5E38\u7528 126\uFF1B\u5DF4\u897F 440/500 kV \u5E38\u7528 72.5\uFF09\uFF0C\u4EE5\u8BA2\u8D27\u89C4\u8303\u4E3A\u51C6\u3002`);
|
|
2884
2884
|
cautionsEn.push(`Neutral of a 400 kV-class winding sized at Um ${umKv} kV (126 is usual in Turkey and Portugal; 72.5 in Brazil at 440/500 kV); the order specification (OS) decides.`);
|
|
2885
2885
|
} else {
|
|
2886
|
-
cautionsZh.push(`\u4E2D\u6027\u70B9\u7EDD\u7F18\u672A\u7ED9\uFF0C\u5148\u6309 Um ${umKv} kV \u9009\uFF0C\u4EE5\u8BA2\u8D27\u89C4\u8303\
|
|
2886
|
+
cautionsZh.push(`\u4E2D\u6027\u70B9\u7EDD\u7F18\u672A\u7ED9\uFF0C\u5148\u6309 Um ${umKv} kV \u9009\uFF0C\u4EE5\u8BA2\u8D27\u89C4\u8303\u4E3A\u51C6\u3002`);
|
|
2887
2887
|
cautionsEn.push(`Neutral insulation not given: sized at Um ${umKv} kV; the order specification (OS) decides.`);
|
|
2888
2888
|
}
|
|
2889
2889
|
}
|
|
@@ -2898,11 +2898,11 @@ function deriveDuty(spec) {
|
|
|
2898
2898
|
cautionsZh.push("230/121 kV \u81EA\u8026\u53D8\u4E2D\u538B\u51FA\u7EBF\u901A\u5E38\u7528 Um 170 kV\uFF0C\u8BF7\u6309\u5382\u5BB6\u6570\u636E\u6838\u5BF9\u3002");
|
|
2899
2899
|
cautionsEn.push("230/121 kV autotransformer MV line lead: Um 170 kV is usual; check the maker's data.");
|
|
2900
2900
|
} else {
|
|
2901
|
-
cautionsZh.push(`\u5F00\u5173\u5BF9\u5730\u7EDD\u7F18\u6682\u6309 ${umKv} kV \u9009\uFF0C\u8BA2\u8D27\u524D\u8BF7\u6309\u8BA2\u8D27\u89C4\u8303\
|
|
2901
|
+
cautionsZh.push(`\u5F00\u5173\u5BF9\u5730\u7EDD\u7F18\u6682\u6309 ${umKv} kV \u9009\uFF0C\u8BA2\u8D27\u524D\u8BF7\u6309\u8BA2\u8D27\u89C4\u8303\u786E\u8BA4\u3002`);
|
|
2902
2902
|
cautionsEn.push(`MV line lead sized at the MV class, Um ${umKv} kV; the order specification (OS) decides.`);
|
|
2903
2903
|
}
|
|
2904
2904
|
} else if (spec.tapPoint === "auto_junction" && umRule === "auto_hv") {
|
|
2905
|
-
cautionsZh.push(`\u5F00\u5173\u5BF9\u5730\u7EDD\u7F18\u6682\u6309 ${umKv} kV \u9009\uFF0C\u8BA2\u8D27\u524D\u8BF7\u6309\u8BA2\u8D27\u89C4\u8303\
|
|
2905
|
+
cautionsZh.push(`\u5F00\u5173\u5BF9\u5730\u7EDD\u7F18\u6682\u6309 ${umKv} kV \u9009\uFF0C\u8BA2\u8D27\u524D\u8BF7\u6309\u8BA2\u8D27\u89C4\u8303\u786E\u8BA4\u3002`);
|
|
2906
2906
|
cautionsEn.push(`Autotransformer junction sized at the HV class, Um ${umKv} kV; the order specification (OS) decides.`);
|
|
2907
2907
|
}
|
|
2908
2908
|
cautionsZh.push("\u81EA\u8026\u53D8\u53EA\u80FD\u7528\u7EC4\u5408\u5F0F\u5F00\u5173\u3002");
|
|
@@ -4116,17 +4116,20 @@ function parseCliArgs(rawArgv) {
|
|
|
4116
4116
|
continue;
|
|
4117
4117
|
}
|
|
4118
4118
|
if (a === "--octc") {
|
|
4119
|
+
if (out.given.has("octc") && !out.octc) throw new CliError("--octc conflicts with --duty oltc. Drop one.");
|
|
4119
4120
|
out.given.add("octc");
|
|
4120
4121
|
out.octc = true;
|
|
4121
4122
|
continue;
|
|
4122
4123
|
}
|
|
4123
4124
|
if (a === "--oil") {
|
|
4125
|
+
if (out.given.has("medium") && out.vacuum) throw new CliError("Give --oil or --vacuum, not both");
|
|
4124
4126
|
out.given.add("medium");
|
|
4125
4127
|
out.oil = true;
|
|
4126
4128
|
out.vacuum = false;
|
|
4127
4129
|
continue;
|
|
4128
4130
|
}
|
|
4129
4131
|
if (a === "--vacuum") {
|
|
4132
|
+
if (out.given.has("medium") && out.oil) throw new CliError("Give --oil or --vacuum, not both");
|
|
4130
4133
|
out.given.add("medium");
|
|
4131
4134
|
out.vacuum = true;
|
|
4132
4135
|
out.oil = false;
|
|
@@ -4152,12 +4155,9 @@ function parseCliArgs(rawArgv) {
|
|
|
4152
4155
|
continue;
|
|
4153
4156
|
}
|
|
4154
4157
|
if (a === "--market") {
|
|
4155
|
-
|
|
4156
|
-
|
|
4157
|
-
|
|
4158
|
-
out.market = v.toUpperCase();
|
|
4159
|
-
i = n;
|
|
4160
|
-
continue;
|
|
4158
|
+
throw new CliError(
|
|
4159
|
+
"--market is removed. State the insulation to earth with --earth-um, and the across-tap levels with --across-li / --across-ac."
|
|
4160
|
+
);
|
|
4161
4161
|
}
|
|
4162
4162
|
if (a === "--across-li" || a === "--across-ac") {
|
|
4163
4163
|
const key = a === "--across-li" ? "acrossLi" : "acrossAc";
|
|
@@ -4404,9 +4404,11 @@ function parseCliArgs(rawArgv) {
|
|
|
4404
4404
|
out.given.add("octc");
|
|
4405
4405
|
const [v, n] = take(i, a);
|
|
4406
4406
|
const d = v.toLowerCase();
|
|
4407
|
+
const had = out.octc;
|
|
4407
4408
|
if (d === "octc" || d === "off" || d === "detc") out.octc = true;
|
|
4408
4409
|
else if (d === "oltc" || d === "on") out.octc = false;
|
|
4409
4410
|
else throw new CliError(`--duty must be oltc or octc`);
|
|
4411
|
+
if (had && !out.octc) throw new CliError("--octc conflicts with --duty oltc. Drop one.");
|
|
4410
4412
|
i = n;
|
|
4411
4413
|
continue;
|
|
4412
4414
|
}
|
|
@@ -4534,20 +4536,18 @@ Flags:
|
|
|
4534
4536
|
--line="\u2026" keeps a line that starts with a dash.
|
|
4535
4537
|
--mva MVA --kv kV Capacity path: Imax from rated I, minus steps, --step-pct, --k
|
|
4536
4538
|
With --iu, --kv alone gives the winding voltage (220 kV
|
|
4537
|
-
combined-only, 330 kV grade
|
|
4539
|
+
combined-only, 330 kV grade) and Um if omitted.
|
|
4538
4540
|
--kind two|auto Transformer kind (--auto = --kind auto). Default two-winding.
|
|
4539
4541
|
--tap P Where the OLTC sits: neutral|line (two-winding),
|
|
4540
4542
|
junction|mv-line (autotransformer, series/common junction
|
|
4541
|
-
or MV line lead).
|
|
4543
|
+
or MV line lead). Default neutral; junction with
|
|
4544
|
+
--kind auto. With --mva it replaces --conn.
|
|
4542
4545
|
--winding star|delta Tapped winding connection (two-winding). Sets the current
|
|
4543
4546
|
formula: star I = S/(\u221A3U), delta I = S/(3U).
|
|
4544
4547
|
--hv kV --mv kV Autotransformer HV / MV rated voltage (with --kind auto).
|
|
4545
4548
|
--earth-um kV OLTC insulation to earth from the OS or maker (catalogue
|
|
4546
4549
|
class). Overrides the rule: line end = winding system,
|
|
4547
4550
|
neutral \u226472.5 full else 72.5 assumed, autotransformer = HV.
|
|
4548
|
-
--market CC Buyer's country for a neutral's assumed Um: IT (line
|
|
4549
|
-
class up to 252), TR (126 on 220 kV class and above).
|
|
4550
|
-
Needs --kv (or --mva/--kv).
|
|
4551
4551
|
--um kV Equipment Um (OLTC). With --kv, derived if omitted.
|
|
4552
4552
|
--ust V Step voltage. With --mva/--kv/--step-pct, derived if omitted;
|
|
4553
4553
|
given, it is the OS figure and a floor (never lowers Ust).
|
|
@@ -4677,8 +4677,7 @@ function computeCliDuty(args) {
|
|
|
4677
4677
|
...earth != null ? { earthUmKv: earth } : {},
|
|
4678
4678
|
...args.osImax != null && args.osImax > 0 ? { statedMaxA: args.osImax } : {},
|
|
4679
4679
|
// --ust used to replace Ust after deriveDuty: basis.stepV disagreed (D3).
|
|
4680
|
-
...args.ust != null && args.ust > 0 ? { statedStepV: args.ust } : {}
|
|
4681
|
-
...args.market ? { market: args.market } : {}
|
|
4680
|
+
...args.ust != null && args.ust > 0 ? { statedStepV: args.ust } : {}
|
|
4682
4681
|
});
|
|
4683
4682
|
}
|
|
4684
4683
|
function checkConflicts(args) {
|
|
@@ -4710,6 +4709,22 @@ function checkConflicts(args) {
|
|
|
4710
4709
|
if (args.typed?.has("--conn") && args.typed.has("--tap") && args.conn === "D" && args.tap === "neutral") {
|
|
4711
4710
|
throw new CliError("--conn D conflicts with --tap neutral: a neutral tap point is star (Y). Drop one.");
|
|
4712
4711
|
}
|
|
4712
|
+
const typed = (...flags) => flags.some((f) => args.typed?.has(f));
|
|
4713
|
+
if (typed("--conn", "--connection") && typed("--tap") && args.conn === "Y" && args.tap === "line_end") {
|
|
4714
|
+
throw new CliError("--conn Y conflicts with --tap line: a line-end tap point is delta (D). Drop one.");
|
|
4715
|
+
}
|
|
4716
|
+
if (args.kind !== "auto" && (typed("--hv") || typed("--mv"))) {
|
|
4717
|
+
throw new CliError("--hv and --mv are autotransformer voltages: add --kind auto (a two-winding transformer takes --kv)");
|
|
4718
|
+
}
|
|
4719
|
+
if (typed("--minus") && args.mva == null) {
|
|
4720
|
+
throw new CliError("--minus sets the lowest-tap current on the --mva path; with --iu give the current itself");
|
|
4721
|
+
}
|
|
4722
|
+
if (typed("--um") && typed("--earth-um") && args.um != null && args.earthUm != null && args.um !== args.earthUm) {
|
|
4723
|
+
throw new CliError(`Give --um or --earth-um, not both: ${args.um} and ${args.earthUm} disagree.`);
|
|
4724
|
+
}
|
|
4725
|
+
if (args.stepPct != null && args.stepPct < 0.1) {
|
|
4726
|
+
throw new CliError(`--step-pct is a percent: 1.25 means 1.25 %. ${args.stepPct} is too small.`);
|
|
4727
|
+
}
|
|
4713
4728
|
if (g("pm") && g("positions") && args.pm != null && args.positions != null) {
|
|
4714
4729
|
const wg = () => plusMinusFromPositions(args.positions, args.reg) === args.pm || [1, 3].some(
|
|
4715
4730
|
(mid) => resolveTapFields({ regulation: args.reg, plusMinusSteps: args.pm, midPositions: mid }).positions === args.positions
|
|
@@ -4745,9 +4760,6 @@ function cliToSelectInput(args) {
|
|
|
4745
4760
|
if (args.stepPct != null && args.mva == null) {
|
|
4746
4761
|
throw new CliError("--step-pct needs --mva/--kv; give --ust on the --iu path");
|
|
4747
4762
|
}
|
|
4748
|
-
if (args.market && args.mva == null && !iuHasVoltage(args)) {
|
|
4749
|
-
throw new CliError("--market needs the winding voltage: add --kv (or --mva/--kv)");
|
|
4750
|
-
}
|
|
4751
4763
|
const duty = cliDuty(args);
|
|
4752
4764
|
let conn = args.conn;
|
|
4753
4765
|
if (duty && args.mva != null) {
|
|
@@ -4784,7 +4796,6 @@ function cliToSelectInput(args) {
|
|
|
4784
4796
|
...duty?.combinedOnly ? { combinedOnly: true } : {},
|
|
4785
4797
|
...duty?.ok && args.kind !== "auto" ? { tapWindingKv: duty.umSystemKv } : {},
|
|
4786
4798
|
// 2026-11-04 r3 ORDERS-11: buyer practice on the grade (TR 72.5C neutrals).
|
|
4787
|
-
...args.market ? { market: args.market } : {},
|
|
4788
4799
|
throughCurrentA: iu,
|
|
4789
4800
|
umKv: um,
|
|
4790
4801
|
stepVoltageV: ust,
|
|
@@ -4849,7 +4860,6 @@ function assumptionsFromArgs(args, family) {
|
|
|
4849
4860
|
items.push(`\u5BF9\u5730 Um ${args.earthUm}\uFF08\u62DB\u6807\u884C\u4E2D\u6027\u70B9 BIL ${args.line.neutralBilKv} kV\uFF09`);
|
|
4850
4861
|
}
|
|
4851
4862
|
if (duty?.umAssumed) items.push(`\u5BF9\u5730 Um ${duty.umKv}\uFF08\u672A\u6307\u5B9A\uFF09`);
|
|
4852
|
-
if (args.market) items.push(`\u5E02\u573A=${args.market}`);
|
|
4853
4863
|
} else {
|
|
4854
4864
|
const conn = cliConnection(args);
|
|
4855
4865
|
const derived = tapSetsConnection(args);
|
|
@@ -4964,7 +4974,6 @@ var ASSUMPTION_EN = [
|
|
|
4964
4974
|
[/^调压绕组 /, "tapped winding "],
|
|
4965
4975
|
[/^调压范围 /, "range "],
|
|
4966
4976
|
["\u5BF9\u5730 Um", "Um to earth"],
|
|
4967
|
-
["\u5E02\u573A=", "market="],
|
|
4968
4977
|
["\u661F\u70B9", "star point"],
|
|
4969
4978
|
["\u7EBF\u7AEF", "line end"],
|
|
4970
4979
|
["\u4E2D\u6027\u70B9", "neutral"],
|
|
@@ -5020,7 +5029,7 @@ function cliNotes(args, input, primaryUmKv, en, engineNotes = []) {
|
|
|
5020
5029
|
const already = duty.cautionsEn.some((c) => c.startsWith("Stated Um"));
|
|
5021
5030
|
if (!already) {
|
|
5022
5031
|
notes.push(
|
|
5023
|
-
en ? `Stated insulation to earth, Um ${duty.umKv} kV, is below the ${duty.ruleUmKv} kV the winding voltage gives. Check the order specification (OS).` : `\u6307\u5B9A\u5BF9\u5730\u7EDD\u7F18 Um ${duty.umKv} kV \u4F4E\u4E8E\u6309\u7ED5\u7EC4\u7535\u538B\u5F97\u51FA\u7684 ${duty.ruleUmKv} kV\uFF0C\u8BF7\u6838\u5BF9\u8BA2\u8D27\u89C4\u8303\
|
|
5032
|
+
en ? `Stated insulation to earth, Um ${duty.umKv} kV, is below the ${duty.ruleUmKv} kV the winding voltage gives. Check the order specification (OS).` : `\u6307\u5B9A\u5BF9\u5730\u7EDD\u7F18 Um ${duty.umKv} kV \u4F4E\u4E8E\u6309\u7ED5\u7EC4\u7535\u538B\u5F97\u51FA\u7684 ${duty.ruleUmKv} kV\uFF0C\u8BF7\u6838\u5BF9\u8BA2\u8D27\u89C4\u8303\u3002`
|
|
5024
5033
|
);
|
|
5025
5034
|
}
|
|
5026
5035
|
}
|
|
@@ -5030,11 +5039,6 @@ function cliNotes(args, input, primaryUmKv, en, engineNotes = []) {
|
|
|
5030
5039
|
en ? `Um ${input.umKv} kV is not a class of this type: sized at Um ${primaryUmKv} kV.` : `Um ${input.umKv} kV \u4E0D\u662F\u8BE5\u578B\u53F7\u7684\u7535\u538B\u7B49\u7EA7\uFF0C\u6309 Um ${primaryUmKv} kV \u9009\u3002`
|
|
5031
5040
|
);
|
|
5032
5041
|
}
|
|
5033
|
-
if (args.market && args.market !== "IT" && args.market !== "TR") {
|
|
5034
|
-
notes.push(
|
|
5035
|
-
en ? `--market ${args.market} has no rule (IT and TR only): not used.` : `--market ${args.market} \u6CA1\u6709\u5BF9\u5E94\u89C4\u5219\uFF08\u53EA\u6709 IT\u3001TR\uFF09\uFF0C\u672A\u4F7F\u7528\u3002`
|
|
5036
|
-
);
|
|
5037
|
-
}
|
|
5038
5042
|
return notes;
|
|
5039
5043
|
}
|
|
5040
5044
|
function lineKindLabel(t, en) {
|