node-opcua-nodeset-padim 2.134.0 → 2.138.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (258) hide show
  1. package/LICENSE +1 -0
  2. package/dist/dt_chemical_substance.d.ts +19 -0
  3. package/dist/dt_chemical_substance.js +4 -0
  4. package/dist/dt_chemical_substance.js.map +1 -0
  5. package/dist/enum_execution_mode_enum.d.ts +1 -1
  6. package/dist/enum_execution_mode_enum.js +1 -1
  7. package/dist/enum_pat_dictionary_enum.d.ts +13 -0
  8. package/dist/enum_pat_dictionary_enum.js +19 -0
  9. package/dist/enum_pat_dictionary_enum.js.map +1 -0
  10. package/dist/enum_reset_mode_enum.d.ts +1 -1
  11. package/dist/enum_reset_mode_enum.js +1 -1
  12. package/dist/index.d.ts +52 -0
  13. package/dist/index.js +52 -0
  14. package/dist/index.js.map +1 -1
  15. package/dist/ua_actual_density_variable.d.ts +4 -3
  16. package/dist/ua_actual_volume_flow_rate_variable.d.ts +4 -3
  17. package/dist/ua_amperometric_analyser.d.ts +12 -0
  18. package/dist/ua_amperometric_analyser.js +3 -0
  19. package/dist/ua_amperometric_analyser.js.map +1 -0
  20. package/dist/ua_amperometric_signal.d.ts +31 -0
  21. package/dist/ua_amperometric_signal.js +3 -0
  22. package/dist/ua_amperometric_signal.js.map +1 -0
  23. package/dist/ua_analog_signal.d.ts +11 -1
  24. package/dist/ua_analog_signal_variable.d.ts +5 -2
  25. package/dist/ua_analytical_measurement_variable.d.ts +4 -3
  26. package/dist/ua_analytical_signal.d.ts +15 -0
  27. package/dist/ua_analytical_signal.js +3 -0
  28. package/dist/ua_analytical_signal.js.map +1 -0
  29. package/dist/ua_calibration_point.d.ts +17 -0
  30. package/dist/ua_calibration_point.js +3 -0
  31. package/dist/ua_calibration_point.js.map +1 -0
  32. package/dist/ua_calibration_point_set.d.ts +13 -0
  33. package/dist/ua_calibration_point_set.js +3 -0
  34. package/dist/ua_calibration_point_set.js.map +1 -0
  35. package/dist/ua_conductivity_meter.d.ts +12 -0
  36. package/dist/ua_conductivity_meter.js +3 -0
  37. package/dist/ua_conductivity_meter.js.map +1 -0
  38. package/dist/ua_conductivity_signal.d.ts +30 -0
  39. package/dist/ua_conductivity_signal.js +3 -0
  40. package/dist/ua_conductivity_signal.js.map +1 -0
  41. package/dist/ua_control_signal.d.ts +1 -1
  42. package/dist/ua_control_variable.d.ts +5 -4
  43. package/dist/ua_discrete_signal_variable.d.ts +2 -1
  44. package/dist/ua_flame_ionisation_detector.d.ts +23 -0
  45. package/dist/ua_flame_ionisation_detector.js +3 -0
  46. package/dist/ua_flame_ionisation_detector.js.map +1 -0
  47. package/dist/ua_flame_ionisation_signal.d.ts +12 -0
  48. package/dist/ua_flame_ionisation_signal.js +3 -0
  49. package/dist/ua_flame_ionisation_signal.js.map +1 -0
  50. package/dist/ua_flow_measurement_variable.d.ts +6 -5
  51. package/dist/ua_general_device_condition_set.d.ts +70 -0
  52. package/dist/ua_general_device_condition_set.js +3 -0
  53. package/dist/ua_general_device_condition_set.js.map +1 -0
  54. package/dist/ua_i_amperometric_calibration.d.ts +20 -0
  55. package/dist/ua_i_amperometric_calibration.js +3 -0
  56. package/dist/ua_i_amperometric_calibration.js.map +1 -0
  57. package/dist/ua_i_amperometric_signal_condition_set.d.ts +21 -0
  58. package/dist/ua_i_amperometric_signal_condition_set.js +3 -0
  59. package/dist/ua_i_amperometric_signal_condition_set.js.map +1 -0
  60. package/dist/ua_i_calibration.d.ts +21 -0
  61. package/dist/ua_i_calibration.js +3 -0
  62. package/dist/ua_i_calibration.js.map +1 -0
  63. package/dist/ua_i_conductivity_calibration.d.ts +16 -0
  64. package/dist/ua_i_conductivity_calibration.js +3 -0
  65. package/dist/ua_i_conductivity_calibration.js.map +1 -0
  66. package/dist/ua_i_conductivity_signal_condition_set.d.ts +23 -0
  67. package/dist/ua_i_conductivity_signal_condition_set.js +3 -0
  68. package/dist/ua_i_conductivity_signal_condition_set.js.map +1 -0
  69. package/dist/ua_i_flame_ionisation_device_condition_set.d.ts +19 -0
  70. package/dist/ua_i_flame_ionisation_device_condition_set.js +3 -0
  71. package/dist/ua_i_flame_ionisation_device_condition_set.js.map +1 -0
  72. package/dist/ua_i_general_device_condition_set.d.ts +17 -0
  73. package/dist/ua_i_general_device_condition_set.js +3 -0
  74. package/dist/ua_i_general_device_condition_set.js.map +1 -0
  75. package/dist/ua_i_non_dispersive_infrared_signal_condition_set.d.ts +21 -0
  76. package/dist/ua_i_non_dispersive_infrared_signal_condition_set.js +3 -0
  77. package/dist/ua_i_non_dispersive_infrared_signal_condition_set.js.map +1 -0
  78. package/dist/ua_i_optical_fluorescense_quenching_calibration.d.ts +20 -0
  79. package/dist/ua_i_optical_fluorescense_quenching_calibration.js +3 -0
  80. package/dist/ua_i_optical_fluorescense_quenching_calibration.js.map +1 -0
  81. package/dist/ua_i_optical_fluorescense_quenching_signal_condition_set.d.ts +21 -0
  82. package/dist/ua_i_optical_fluorescense_quenching_signal_condition_set.js +3 -0
  83. package/dist/ua_i_optical_fluorescense_quenching_signal_condition_set.js.map +1 -0
  84. package/dist/ua_i_paramagnetic_signal_condition_set.d.ts +17 -0
  85. package/dist/ua_i_paramagnetic_signal_condition_set.js +3 -0
  86. package/dist/ua_i_paramagnetic_signal_condition_set.js.map +1 -0
  87. package/dist/ua_i_ph_calibration.d.ts +19 -0
  88. package/dist/ua_i_ph_calibration.js +3 -0
  89. package/dist/ua_i_ph_calibration.js.map +1 -0
  90. package/dist/ua_i_ph_signal_condition_set.d.ts +25 -0
  91. package/dist/ua_i_ph_signal_condition_set.js +3 -0
  92. package/dist/ua_i_ph_signal_condition_set.js.map +1 -0
  93. package/dist/ua_i_thermal_conductivity_signal_condition_set.d.ts +16 -0
  94. package/dist/ua_i_thermal_conductivity_signal_condition_set.js +3 -0
  95. package/dist/ua_i_thermal_conductivity_signal_condition_set.js.map +1 -0
  96. package/dist/ua_i_toc_device_condition_set.d.ts +22 -0
  97. package/dist/ua_i_toc_device_condition_set.js +3 -0
  98. package/dist/ua_i_toc_device_condition_set.js.map +1 -0
  99. package/dist/ua_i_toc_signal_condition_set.d.ts +24 -0
  100. package/dist/ua_i_toc_signal_condition_set.js +3 -0
  101. package/dist/ua_i_toc_signal_condition_set.js.map +1 -0
  102. package/dist/ua_i_tunable_diode_laser_signal_condition_set.d.ts +22 -0
  103. package/dist/ua_i_tunable_diode_laser_signal_condition_set.js +3 -0
  104. package/dist/ua_i_tunable_diode_laser_signal_condition_set.js.map +1 -0
  105. package/dist/ua_i_zirconium_dioxide_signal_condition_set.d.ts +19 -0
  106. package/dist/ua_i_zirconium_dioxide_signal_condition_set.js +3 -0
  107. package/dist/ua_i_zirconium_dioxide_signal_condition_set.js.map +1 -0
  108. package/dist/ua_level_measurement_variable.d.ts +4 -3
  109. package/dist/ua_mass_flow_rate_variable.d.ts +4 -3
  110. package/dist/ua_multi_state_discrete_control_signal.d.ts +16 -0
  111. package/dist/ua_multi_state_discrete_control_signal.js +3 -0
  112. package/dist/ua_multi_state_discrete_control_signal.js.map +1 -0
  113. package/dist/ua_multi_state_discrete_control_variable.d.ts +22 -0
  114. package/dist/ua_multi_state_discrete_control_variable.js +3 -0
  115. package/dist/ua_multi_state_discrete_control_variable.js.map +1 -0
  116. package/dist/ua_multi_state_discrete_signal_variable.d.ts +1 -0
  117. package/dist/ua_non_dispersive_infrared_gas_analyser.d.ts +12 -0
  118. package/dist/ua_non_dispersive_infrared_gas_analyser.js +3 -0
  119. package/dist/ua_non_dispersive_infrared_gas_analyser.js.map +1 -0
  120. package/dist/ua_non_dispersive_infrared_signal.d.ts +24 -0
  121. package/dist/ua_non_dispersive_infrared_signal.js +3 -0
  122. package/dist/ua_non_dispersive_infrared_signal.js.map +1 -0
  123. package/dist/ua_normalized_volume_flow_rate_variable.d.ts +4 -3
  124. package/dist/ua_optical_fluorescense_quenching_sensor.d.ts +12 -0
  125. package/dist/ua_optical_fluorescense_quenching_sensor.js +3 -0
  126. package/dist/ua_optical_fluorescense_quenching_sensor.js.map +1 -0
  127. package/dist/ua_optical_fluorescense_quenching_signal.d.ts +31 -0
  128. package/dist/ua_optical_fluorescense_quenching_signal.js +3 -0
  129. package/dist/ua_optical_fluorescense_quenching_signal.js.map +1 -0
  130. package/dist/ua_padim.d.ts +11 -3
  131. package/dist/ua_paramagnetic_gas_analyser.d.ts +12 -0
  132. package/dist/ua_paramagnetic_gas_analyser.js +3 -0
  133. package/dist/ua_paramagnetic_gas_analyser.js.map +1 -0
  134. package/dist/ua_paramagnetic_signal.d.ts +21 -0
  135. package/dist/ua_paramagnetic_signal.js +3 -0
  136. package/dist/ua_paramagnetic_signal.js.map +1 -0
  137. package/dist/ua_pat_measurement_variable.d.ts +21 -0
  138. package/dist/ua_pat_measurement_variable.js +3 -0
  139. package/dist/ua_pat_measurement_variable.js.map +1 -0
  140. package/dist/ua_ph_meter.d.ts +12 -0
  141. package/dist/ua_ph_meter.js +3 -0
  142. package/dist/ua_ph_meter.js.map +1 -0
  143. package/dist/ua_ph_signal.d.ts +34 -0
  144. package/dist/ua_ph_signal.js +3 -0
  145. package/dist/ua_ph_signal.js.map +1 -0
  146. package/dist/ua_pressure_measurement_variable.d.ts +4 -3
  147. package/dist/ua_process_analyser.d.ts +12 -0
  148. package/dist/ua_process_analyser.js +3 -0
  149. package/dist/ua_process_analyser.js.map +1 -0
  150. package/dist/ua_temperature_measurement_variable.d.ts +8 -6
  151. package/dist/ua_thermal_conductivity_gas_analyser.d.ts +12 -0
  152. package/dist/ua_thermal_conductivity_gas_analyser.js +3 -0
  153. package/dist/ua_thermal_conductivity_gas_analyser.js.map +1 -0
  154. package/dist/ua_thermal_conductivity_signal.d.ts +20 -0
  155. package/dist/ua_thermal_conductivity_signal.js +3 -0
  156. package/dist/ua_thermal_conductivity_signal.js.map +1 -0
  157. package/dist/ua_toc_analyser.d.ts +26 -0
  158. package/dist/ua_toc_analyser.js +3 -0
  159. package/dist/ua_toc_analyser.js.map +1 -0
  160. package/dist/ua_toc_signal.d.ts +27 -0
  161. package/dist/ua_toc_signal.js +3 -0
  162. package/dist/ua_toc_signal.js.map +1 -0
  163. package/dist/ua_totalizer_variable.d.ts +2 -1
  164. package/dist/ua_tunable_diode_laser_signal.d.ts +26 -0
  165. package/dist/ua_tunable_diode_laser_signal.js +3 -0
  166. package/dist/ua_tunable_diode_laser_signal.js.map +1 -0
  167. package/dist/ua_tunable_diode_laser_spectrometer.d.ts +12 -0
  168. package/dist/ua_tunable_diode_laser_spectrometer.js +3 -0
  169. package/dist/ua_tunable_diode_laser_spectrometer.js.map +1 -0
  170. package/dist/ua_two_state_discrete_control_signal.d.ts +15 -0
  171. package/dist/ua_two_state_discrete_control_signal.js +3 -0
  172. package/dist/ua_two_state_discrete_control_signal.js.map +1 -0
  173. package/dist/ua_two_state_discrete_control_variable.d.ts +23 -0
  174. package/dist/ua_two_state_discrete_control_variable.js +3 -0
  175. package/dist/ua_two_state_discrete_control_variable.js.map +1 -0
  176. package/dist/ua_two_state_discrete_signal.d.ts +1 -1
  177. package/dist/ua_two_state_discrete_signal_variable.d.ts +6 -5
  178. package/dist/ua_zirconium_dioxide_analyser.d.ts +12 -0
  179. package/dist/ua_zirconium_dioxide_analyser.js +3 -0
  180. package/dist/ua_zirconium_dioxide_analyser.js.map +1 -0
  181. package/dist/ua_zirconium_dioxide_signal.d.ts +23 -0
  182. package/dist/ua_zirconium_dioxide_signal.js +3 -0
  183. package/dist/ua_zirconium_dioxide_signal.js.map +1 -0
  184. package/package.json +9 -8
  185. package/source/dt_chemical_substance.ts +19 -0
  186. package/source/enum_execution_mode_enum.ts +1 -1
  187. package/source/enum_pat_dictionary_enum.ts +15 -0
  188. package/source/enum_reset_mode_enum.ts +1 -1
  189. package/source/index.ts +53 -1
  190. package/source/ua_actual_density_variable.ts +4 -3
  191. package/source/ua_actual_volume_flow_rate_variable.ts +4 -3
  192. package/source/ua_amperometric_analyser.ts +13 -0
  193. package/source/ua_amperometric_signal.ts +33 -0
  194. package/source/ua_analog_signal.ts +12 -3
  195. package/source/ua_analog_signal_variable.ts +6 -3
  196. package/source/ua_analytical_measurement_variable.ts +4 -3
  197. package/source/ua_analytical_signal.ts +20 -0
  198. package/source/ua_calibration_point.ts +18 -0
  199. package/source/ua_calibration_point_set.ts +15 -0
  200. package/source/ua_conductivity_meter.ts +13 -0
  201. package/source/ua_conductivity_signal.ts +32 -0
  202. package/source/ua_control_signal.ts +2 -2
  203. package/source/ua_control_variable.ts +5 -4
  204. package/source/ua_discrete_signal_variable.ts +2 -1
  205. package/source/ua_flame_ionisation_detector.ts +24 -0
  206. package/source/ua_flame_ionisation_signal.ts +13 -0
  207. package/source/ua_flow_measurement_variable.ts +6 -5
  208. package/source/ua_general_device_condition_set.ts +71 -0
  209. package/source/ua_i_amperometric_calibration.ts +22 -0
  210. package/source/ua_i_amperometric_signal_condition_set.ts +23 -0
  211. package/source/ua_i_calibration.ts +25 -0
  212. package/source/ua_i_conductivity_calibration.ts +18 -0
  213. package/source/ua_i_conductivity_signal_condition_set.ts +28 -0
  214. package/source/ua_i_flame_ionisation_device_condition_set.ts +21 -0
  215. package/source/ua_i_general_device_condition_set.ts +22 -0
  216. package/source/ua_i_non_dispersive_infrared_signal_condition_set.ts +23 -0
  217. package/source/ua_i_optical_fluorescense_quenching_calibration.ts +22 -0
  218. package/source/ua_i_optical_fluorescense_quenching_signal_condition_set.ts +23 -0
  219. package/source/ua_i_paramagnetic_signal_condition_set.ts +19 -0
  220. package/source/ua_i_ph_calibration.ts +21 -0
  221. package/source/ua_i_ph_signal_condition_set.ts +30 -0
  222. package/source/ua_i_thermal_conductivity_signal_condition_set.ts +18 -0
  223. package/source/ua_i_toc_device_condition_set.ts +24 -0
  224. package/source/ua_i_toc_signal_condition_set.ts +26 -0
  225. package/source/ua_i_tunable_diode_laser_signal_condition_set.ts +24 -0
  226. package/source/ua_i_zirconium_dioxide_signal_condition_set.ts +21 -0
  227. package/source/ua_level_measurement_variable.ts +4 -3
  228. package/source/ua_mass_flow_rate_variable.ts +4 -3
  229. package/source/ua_multi_state_discrete_control_signal.ts +21 -0
  230. package/source/ua_multi_state_discrete_control_variable.ts +23 -0
  231. package/source/ua_multi_state_discrete_signal_variable.ts +1 -0
  232. package/source/ua_non_dispersive_infrared_gas_analyser.ts +13 -0
  233. package/source/ua_non_dispersive_infrared_signal.ts +25 -0
  234. package/source/ua_normalized_volume_flow_rate_variable.ts +4 -3
  235. package/source/ua_optical_fluorescense_quenching_sensor.ts +13 -0
  236. package/source/ua_optical_fluorescense_quenching_signal.ts +33 -0
  237. package/source/ua_padim.ts +10 -2
  238. package/source/ua_paramagnetic_gas_analyser.ts +13 -0
  239. package/source/ua_paramagnetic_signal.ts +22 -0
  240. package/source/ua_pat_measurement_variable.ts +22 -0
  241. package/source/ua_ph_meter.ts +13 -0
  242. package/source/ua_ph_signal.ts +36 -0
  243. package/source/ua_pressure_measurement_variable.ts +4 -3
  244. package/source/ua_process_analyser.ts +13 -0
  245. package/source/ua_temperature_measurement_variable.ts +8 -6
  246. package/source/ua_thermal_conductivity_gas_analyser.ts +13 -0
  247. package/source/ua_thermal_conductivity_signal.ts +21 -0
  248. package/source/ua_toc_analyser.ts +27 -0
  249. package/source/ua_toc_signal.ts +28 -0
  250. package/source/ua_totalizer_variable.ts +3 -2
  251. package/source/ua_tunable_diode_laser_signal.ts +27 -0
  252. package/source/ua_tunable_diode_laser_spectrometer.ts +13 -0
  253. package/source/ua_two_state_discrete_control_signal.ts +21 -0
  254. package/source/ua_two_state_discrete_control_variable.ts +24 -0
  255. package/source/ua_two_state_discrete_signal.ts +1 -1
  256. package/source/ua_two_state_discrete_signal_variable.ts +6 -5
  257. package/source/ua_zirconium_dioxide_analyser.ts +13 -0
  258. package/source/ua_zirconium_dioxide_signal.ts +24 -0
@@ -0,0 +1,33 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { UAObject, UAProperty } from "node-opcua-address-space-base"
3
+ import { DataType } from "node-opcua-variant"
4
+ import { UInt32 } from "node-opcua-basic-types"
5
+ import { UAAnalogUnit } from "node-opcua-nodeset-ua/source/ua_analog_unit"
6
+ import { UAAnalogSignal_$SignalCalibrationIdentifier$ } from "./ua_analog_signal"
7
+ import { UAAnalyticalSignal, UAAnalyticalSignal_Base } from "./ua_analytical_signal"
8
+ export interface UAAmperometricSignal_$SignalCalibrationIdentifier$ extends UAAnalogSignal_$SignalCalibrationIdentifier$ { // Object
9
+ absoluteAirPressure?: UAAnalogUnit<number, DataType.Float>;
10
+ amperometricSensorSlope?: UAAnalogUnit<number, DataType.Float>;
11
+ amperometricSensorZeroPoint?: UAAnalogUnit<number, DataType.Float>;
12
+ sensorT90?: UAProperty<number, DataType.Float>;
13
+ }
14
+ export interface UAAmperometricSignal_signalConditionSet extends UAObject { // Object
15
+ sensorCleaningsCounter?: UAProperty<UInt32, DataType.UInt32>;
16
+ sensorNextCalibration?: UAAnalogUnit<UInt32, DataType.UInt32>;
17
+ sensorSterilisationsCounter?: UAProperty<UInt32, DataType.UInt32>;
18
+ sensingElementTemperature?: UAAnalogUnit<number, DataType.Float>;
19
+ }
20
+ /**
21
+ * | | |
22
+ * |----------------|------------------------------------------------------------|
23
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
24
+ * |nodeClass |ObjectType |
25
+ * |typedDefinition |AmperometricSignalType i=1066 |
26
+ * |isAbstract |false |
27
+ */
28
+ export interface UAAmperometricSignal_Base extends UAAnalyticalSignal_Base {
29
+ // PlaceHolder for $SignalCalibrationIdentifier$
30
+ signalConditionSet?: UAAmperometricSignal_signalConditionSet;
31
+ }
32
+ export interface UAAmperometricSignal extends Omit<UAAnalyticalSignal, "$SignalCalibrationIdentifier$"|"signalConditionSet">, UAAmperometricSignal_Base {
33
+ }
@@ -1,11 +1,18 @@
1
1
  // ----- this file has been automatically generated - do not edit
2
- import { UAMethod } from "node-opcua-address-space-base"
3
- import { DataType, Variant, VariantOptions } from "node-opcua-variant"
2
+ import { UAObject, UAMethod, UAProperty } from "node-opcua-address-space-base"
3
+ import { DataType } from "node-opcua-variant"
4
4
  import { EUInformation } from "node-opcua-data-access"
5
- import { UAString } from "node-opcua-basic-types"
5
+ import { UInt32 } from "node-opcua-basic-types"
6
6
  import { DTRange } from "node-opcua-nodeset-ua/source/dt_range"
7
+ import { UAMultiStateDictionaryEntryDiscrete } from "node-opcua-nodeset-ua/source/ua_multi_state_dictionary_entry_discrete"
8
+ import { UACalibrationPointSet } from "./ua_calibration_point_set"
7
9
  import { UASignal, UASignal_Base } from "./ua_signal"
8
10
  import { UAAnalogSignalVariable } from "./ua_analog_signal_variable"
11
+ export interface UAAnalogSignal_$SignalCalibrationIdentifier$ extends UAObject { // Object
12
+ calibrationTimestamp?: UAProperty<Date, DataType.DateTime>;
13
+ typeOfCalibration?: UAMultiStateDictionaryEntryDiscrete<UInt32, DataType.UInt32>;
14
+ calibrationPointSet?: UACalibrationPointSet;
15
+ }
9
16
  /**
10
17
  * | | |
11
18
  * |----------------|------------------------------------------------------------|
@@ -17,6 +24,8 @@ import { UAAnalogSignalVariable } from "./ua_analog_signal_variable"
17
24
  export interface UAAnalogSignal_Base extends UASignal_Base {
18
25
  zeroPointAdjustment?: UAMethod;
19
26
  analogSignal: UAAnalogSignalVariable<any, any>;
27
+ // PlaceHolder for $SignalCalibrationIdentifier$
28
+ signalConditionSet?: UAObject;
20
29
  }
21
30
  export interface UAAnalogSignal extends UASignal, UAAnalogSignal_Base {
22
31
  }
@@ -1,6 +1,7 @@
1
1
  // ----- this file has been automatically generated - do not edit
2
2
  import { UAProperty } from "node-opcua-address-space-base"
3
- import { DataType, Variant } from "node-opcua-variant"
3
+ import { DataType } from "node-opcua-variant"
4
+ import { EUInformation } from "node-opcua-data-access"
4
5
  import { UAAnalogUnitRange, UAAnalogUnitRange_Base } from "node-opcua-nodeset-ua/source/ua_analog_unit_range"
5
6
  import { UABaseDataVariable } from "node-opcua-nodeset-ua/source/ua_base_data_variable"
6
7
  /**
@@ -10,7 +11,8 @@ import { UABaseDataVariable } from "node-opcua-nodeset-ua/source/ua_base_data_va
10
11
  * |nodeClass |VariableType |
11
12
  * |typedDefinition |AnalogSignalVariableType i=1111 |
12
13
  * |dataType |Variant |
13
- * |dataType Name |Variant i=26 |
14
+ * |dataType Name |(number | number[]) i=26 |
15
+ * |value rank |-2 |
14
16
  * |isAbstract |false |
15
17
  */
16
18
  export interface UAAnalogSignalVariable_Base<T, DT extends DataType> extends UAAnalogUnitRange_Base<T, DT> {
@@ -18,6 +20,7 @@ export interface UAAnalogSignalVariable_Base<T, DT extends DataType> extends UA
18
20
  actualValue?: UABaseDataVariable<any, any>;
19
21
  simulationValue?: UABaseDataVariable<any, any>;
20
22
  damping?: UAProperty<number, DataType.Float>;
23
+ engineeringUnits: UAProperty<EUInformation, DataType.ExtensionObject>;
21
24
  }
22
- export interface UAAnalogSignalVariable<T, DT extends DataType> extends UAAnalogUnitRange<T, DT>, UAAnalogSignalVariable_Base<T, DT> {
25
+ export interface UAAnalogSignalVariable<T, DT extends DataType> extends Omit<UAAnalogUnitRange<T, DT>, "engineeringUnits">, UAAnalogSignalVariable_Base<T, DT> {
23
26
  }
@@ -8,9 +8,10 @@ import { UAAnalogSignalVariable, UAAnalogSignalVariable_Base } from "./ua_analog
8
8
  * |nodeClass |VariableType |
9
9
  * |typedDefinition |AnalyticalMeasurementVariableType i=1127 |
10
10
  * |dataType |Float |
11
- * |dataType Name |number i=10 |
11
+ * |dataType Name |(number | number[]) i=10 |
12
+ * |value rank |-2 |
12
13
  * |isAbstract |false |
13
14
  */
14
- export type UAAnalyticalMeasurementVariable_Base<T extends number> = UAAnalogSignalVariable_Base<T, DataType.Float>;
15
- export interface UAAnalyticalMeasurementVariable<T extends number> extends UAAnalogSignalVariable<T, DataType.Float>, UAAnalyticalMeasurementVariable_Base<T> {
15
+ export type UAAnalyticalMeasurementVariable_Base<T extends (number | number[])> = UAAnalogSignalVariable_Base<T, DataType.Float>;
16
+ export interface UAAnalyticalMeasurementVariable<T extends (number | number[])> extends UAAnalogSignalVariable<T, DataType.Float>, UAAnalyticalMeasurementVariable_Base<T> {
16
17
  }
@@ -0,0 +1,20 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { DataType } from "node-opcua-variant"
3
+ import { EUInformation } from "node-opcua-data-access"
4
+ import { DTRange } from "node-opcua-nodeset-ua/source/dt_range"
5
+ import { DTChemicalSubstance } from "./dt_chemical_substance"
6
+ import { UAAnalogSignal, UAAnalogSignal_Base } from "./ua_analog_signal"
7
+ import { UAPatMeasurementVariable } from "./ua_pat_measurement_variable"
8
+ /**
9
+ * | | |
10
+ * |----------------|------------------------------------------------------------|
11
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
12
+ * |nodeClass |ObjectType |
13
+ * |typedDefinition |AnalyticalSignalType i=1065 |
14
+ * |isAbstract |false |
15
+ */
16
+ export interface UAAnalyticalSignal_Base extends UAAnalogSignal_Base {
17
+ analogSignal: UAPatMeasurementVariable<number>;
18
+ }
19
+ export interface UAAnalyticalSignal extends Omit<UAAnalogSignal, "analogSignal">, UAAnalyticalSignal_Base {
20
+ }
@@ -0,0 +1,18 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { UAObject } from "node-opcua-address-space-base"
3
+ import { DataType } from "node-opcua-variant"
4
+ import { UABaseDataVariable } from "node-opcua-nodeset-ua/source/ua_base_data_variable"
5
+ /**
6
+ * | | |
7
+ * |----------------|------------------------------------------------------------|
8
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
9
+ * |nodeClass |ObjectType |
10
+ * |typedDefinition |CalibrationPointType i=1042 |
11
+ * |isAbstract |false |
12
+ */
13
+ export interface UACalibrationPoint_Base {
14
+ calibrationActualValue?: UABaseDataVariable<(number | number[]), DataType.Float>;
15
+ calibrationSetpoint?: UABaseDataVariable<(number | number[]), DataType.Float>;
16
+ }
17
+ export interface UACalibrationPoint extends UAObject, UACalibrationPoint_Base {
18
+ }
@@ -0,0 +1,15 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { UAObject } from "node-opcua-address-space-base"
3
+ /**
4
+ * | | |
5
+ * |----------------|------------------------------------------------------------|
6
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
7
+ * |nodeClass |ObjectType |
8
+ * |typedDefinition |CalibrationPointSetType i=1043 |
9
+ * |isAbstract |false |
10
+ */
11
+ export interface UACalibrationPointSet_Base {
12
+ // PlaceHolder for $CalibrationPointIdentifier$
13
+ }
14
+ export interface UACalibrationPointSet extends UAObject, UACalibrationPointSet_Base {
15
+ }
@@ -0,0 +1,13 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { UAProcessAnalyser, UAProcessAnalyser_Base } from "./ua_process_analyser"
3
+ /**
4
+ * | | |
5
+ * |----------------|------------------------------------------------------------|
6
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
7
+ * |nodeClass |ObjectType |
8
+ * |typedDefinition |ConductivityMeterType i=1084 |
9
+ * |isAbstract |false |
10
+ */
11
+ export type UAConductivityMeter_Base = UAProcessAnalyser_Base;
12
+ export interface UAConductivityMeter extends UAProcessAnalyser, UAConductivityMeter_Base {
13
+ }
@@ -0,0 +1,32 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { UAObject, UAProperty } from "node-opcua-address-space-base"
3
+ import { DataType } from "node-opcua-variant"
4
+ import { UInt32 } from "node-opcua-basic-types"
5
+ import { UAAnalogUnit } from "node-opcua-nodeset-ua/source/ua_analog_unit"
6
+ import { UAMultiStateDictionaryEntryDiscrete } from "node-opcua-nodeset-ua/source/ua_multi_state_dictionary_entry_discrete"
7
+ import { UAAnalogSignal_$SignalCalibrationIdentifier$ } from "./ua_analog_signal"
8
+ import { UAAnalyticalSignal, UAAnalyticalSignal_Base } from "./ua_analytical_signal"
9
+ export interface UAConductivitySignal_$SignalCalibrationIdentifier$ extends UAAnalogSignal_$SignalCalibrationIdentifier$ { // Object
10
+ conductivityCellConstant?: UAAnalogUnit<number, DataType.Float>;
11
+ }
12
+ export interface UAConductivitySignal_signalConditionSet extends UAObject { // Object
13
+ conductivityMeasuringMethod?: UAMultiStateDictionaryEntryDiscrete<UInt32, DataType.UInt32>;
14
+ sensorCleaningsCounter?: UAProperty<UInt32, DataType.UInt32>;
15
+ sensorSterilisationsCounter?: UAProperty<UInt32, DataType.UInt32>;
16
+ sensingElementTemperature?: UAAnalogUnit<number, DataType.Float>;
17
+ temperatureCompensationStyle?: UAMultiStateDictionaryEntryDiscrete<UInt32, DataType.UInt32>;
18
+ }
19
+ /**
20
+ * | | |
21
+ * |----------------|------------------------------------------------------------|
22
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
23
+ * |nodeClass |ObjectType |
24
+ * |typedDefinition |ConductivitySignalType i=1067 |
25
+ * |isAbstract |false |
26
+ */
27
+ export interface UAConductivitySignal_Base extends UAAnalyticalSignal_Base {
28
+ // PlaceHolder for $SignalCalibrationIdentifier$
29
+ signalConditionSet?: UAConductivitySignal_signalConditionSet;
30
+ }
31
+ export interface UAConductivitySignal extends Omit<UAAnalyticalSignal, "$SignalCalibrationIdentifier$"|"signalConditionSet">, UAConductivitySignal_Base {
32
+ }
@@ -1,6 +1,6 @@
1
1
  // ----- this file has been automatically generated - do not edit
2
2
  import { UAMethod } from "node-opcua-address-space-base"
3
- import { DataType, Variant, VariantOptions } from "node-opcua-variant"
3
+ import { DataType } from "node-opcua-variant"
4
4
  import { LocalizedText } from "node-opcua-data-model"
5
5
  import { EUInformation } from "node-opcua-data-access"
6
6
  import { NodeId } from "node-opcua-nodeid"
@@ -20,7 +20,7 @@ import { UAControlVariable } from "./ua_control_variable"
20
20
  */
21
21
  export interface UAControlSignal_Base extends UASignal_Base {
22
22
  autoAdjustPositioner?: UAMethod;
23
- controlSignal: UAControlVariable<number>;
23
+ controlSignal: UAControlVariable<(number | number[])>;
24
24
  }
25
25
  export interface UAControlSignal extends UASignal, UAControlSignal_Base {
26
26
  }
@@ -11,13 +11,14 @@ import { UAAnalogSignalVariable, UAAnalogSignalVariable_Base } from "./ua_analog
11
11
  * |nodeClass |VariableType |
12
12
  * |typedDefinition |ControlVariableType i=1125 |
13
13
  * |dataType |Float |
14
- * |dataType Name |number i=10 |
14
+ * |dataType Name |(number | number[]) i=10 |
15
+ * |value rank |-2 |
15
16
  * |isAbstract |false |
16
17
  */
17
- export interface UAControlVariable_Base<T extends number> extends UAAnalogSignalVariable_Base<T, DataType.Float> {
18
- setpoint: UABaseAnalog<number, DataType.Float>;
18
+ export interface UAControlVariable_Base<T extends (number | number[])> extends UAAnalogSignalVariable_Base<T, DataType.Float> {
19
+ setpoint: UABaseAnalog<(number | number[]), DataType.Float>;
19
20
  operatingDirection: UAMultiStateDictionaryEntryDiscrete<UInt32, DataType.UInt32>;
20
21
  actuatorType: UAMultiStateDictionaryEntryDiscrete<UInt32, DataType.UInt32>;
21
22
  }
22
- export interface UAControlVariable<T extends number> extends UAAnalogSignalVariable<T, DataType.Float>, UAControlVariable_Base<T> {
23
+ export interface UAControlVariable<T extends (number | number[])> extends UAAnalogSignalVariable<T, DataType.Float>, UAControlVariable_Base<T> {
23
24
  }
@@ -9,7 +9,8 @@ import { UABaseDataVariable } from "node-opcua-nodeset-ua/source/ua_base_data_va
9
9
  * |nodeClass |VariableType |
10
10
  * |typedDefinition |DiscreteSignalVariableType i=1143 |
11
11
  * |dataType |Null |
12
- * |dataType Name |VariantOptions i=0 |
12
+ * |dataType Name |(VariantOptions | VariantOptions[]) i=0 |
13
+ * |value rank |-2 |
13
14
  * |isAbstract |false |
14
15
  */
15
16
  export interface UADiscreteSignalVariable_Base<T, DT extends DataType> extends UADiscreteItem_Base<T, DT> {
@@ -0,0 +1,24 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { DataType } from "node-opcua-variant"
3
+ import { UAAnalogUnit } from "node-opcua-nodeset-ua/source/ua_analog_unit"
4
+ import { UAPADIM_deviceConditionSet } from "./ua_padim"
5
+ import { UAProcessAnalyser, UAProcessAnalyser_Base } from "./ua_process_analyser"
6
+ export interface UAFlameIonisationDetector_deviceConditionSet extends UAPADIM_deviceConditionSet { // Object
7
+ blockTemperature?: UAAnalogUnit<number, DataType.Float>;
8
+ catalystTemperature?: UAAnalogUnit<number, DataType.Float>;
9
+ combustionAirPressure?: UAAnalogUnit<number, DataType.Float>;
10
+ fuelGasPressure?: UAAnalogUnit<number, DataType.Float>;
11
+ }
12
+ /**
13
+ * | | |
14
+ * |----------------|------------------------------------------------------------|
15
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
16
+ * |nodeClass |ObjectType |
17
+ * |typedDefinition |FlameIonisationDetectorType i=1085 |
18
+ * |isAbstract |false |
19
+ */
20
+ export interface UAFlameIonisationDetector_Base extends UAProcessAnalyser_Base {
21
+ deviceConditionSet?: UAFlameIonisationDetector_deviceConditionSet;
22
+ }
23
+ export interface UAFlameIonisationDetector extends Omit<UAProcessAnalyser, "deviceConditionSet">, UAFlameIonisationDetector_Base {
24
+ }
@@ -0,0 +1,13 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { UAAnalyticalSignal, UAAnalyticalSignal_Base } from "./ua_analytical_signal"
3
+ /**
4
+ * | | |
5
+ * |----------------|------------------------------------------------------------|
6
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
7
+ * |nodeClass |ObjectType |
8
+ * |typedDefinition |FlameIonisationSignalType i=1069 |
9
+ * |isAbstract |false |
10
+ */
11
+ export type UAFlameIonisationSignal_Base = UAAnalyticalSignal_Base;
12
+ export interface UAFlameIonisationSignal extends UAAnalyticalSignal, UAFlameIonisationSignal_Base {
13
+ }
@@ -14,12 +14,13 @@ import { UAAnalogSignalVariable, UAAnalogSignalVariable_Base } from "./ua_analog
14
14
  * |nodeClass |VariableType |
15
15
  * |typedDefinition |FlowMeasurementVariableType i=1122 |
16
16
  * |dataType |Float |
17
- * |dataType Name |number i=10 |
17
+ * |dataType Name |(number | number[]) i=10 |
18
+ * |value rank |-2 |
18
19
  * |isAbstract |false |
19
20
  */
20
- export interface UAFlowMeasurementVariable_Base<T extends number> extends UAAnalogSignalVariable_Base<T, DataType.Float> {
21
- lowFlowCutOff: UAProperty<number, DataType.Float>;
22
- flowDirection?: UAMultiStateDictionaryEntryDiscrete<UInt32, DataType.UInt32>;
21
+ export interface UAFlowMeasurementVariable_Base<T extends (number | number[])> extends UAAnalogSignalVariable_Base<T, DataType.Float> {
22
+ lowFlowCutOff: UAProperty<(number | number[]), DataType.Float>;
23
+ flowDirection?: UAMultiStateDictionaryEntryDiscrete<(UInt32 | UInt32[]), DataType.UInt32>;
23
24
  }
24
- export interface UAFlowMeasurementVariable<T extends number> extends UAAnalogSignalVariable<T, DataType.Float>, UAFlowMeasurementVariable_Base<T> {
25
+ export interface UAFlowMeasurementVariable<T extends (number | number[])> extends UAAnalogSignalVariable<T, DataType.Float>, UAFlowMeasurementVariable_Base<T> {
25
26
  }
@@ -0,0 +1,71 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { UAObject, UAProperty } from "node-opcua-address-space-base"
3
+ import { DataType } from "node-opcua-variant"
4
+ import { UAAnalogUnit } from "node-opcua-nodeset-ua/source/ua_analog_unit"
5
+ /**
6
+ * | | |
7
+ * |----------------|------------------------------------------------------------|
8
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
9
+ * |nodeClass |ObjectType |
10
+ * |typedDefinition |GeneralDeviceConditionSetType i=1051 |
11
+ * |isAbstract |false |
12
+ */
13
+ export interface UAGeneralDeviceConditionSet_Base {
14
+ internalTemperature?: UAAnalogUnit<(number | number[]), DataType.Float>;
15
+ residualLife?: UAProperty<number, DataType.Float>;
16
+ /**
17
+ * operationCycleCounter
18
+ * Operation cycle counter is counting the times the
19
+ * Device switches from not performing an activity
20
+ * to performing an activity. For example, each time
21
+ * a valve starts moving, is counted. This value
22
+ * shall only increase during the lifetime of the
23
+ * Device and shall not be reset when the Device is
24
+ * restarted.
25
+ */
26
+ operationCycleCounter?: UAProperty<any, any>;
27
+ /**
28
+ * operationDuration
29
+ * Operation duration is the duration the Device has
30
+ * been powered and performing an activity. This
31
+ * counter is intended for Devices where a
32
+ * distinction is made between switched on and in
33
+ * operation. For example, a drive might be powered
34
+ * on but not operating. It is not intended for
35
+ * Devices always performing an activity like
36
+ * sensors always measuring data. This value shall
37
+ * only increase during the lifetime of the Device
38
+ * and shall not be reset when the Device is
39
+ * restarted. The OperationDuration is provided as
40
+ * Duration, i.e., in milliseconds or even fractions
41
+ * of a millisecond. However, the Server is not
42
+ * expected to update the value in such a high
43
+ * frequency, but maybe once a minute or once an
44
+ * hour, depending on the application.
45
+ */
46
+ operationDuration?: UAProperty<number, DataType.Double>;
47
+ /**
48
+ * powerOnDuration
49
+ * Power on duration is the duration the Device has
50
+ * been powered. The main purpose is to determine
51
+ * the time in which degradation of the Device
52
+ * occurred. The details, when the time is counted,
53
+ * is implementation-specific. Companion
54
+ * specifications might define specific rules.
55
+ * Typically, when the Device has supply voltage and
56
+ * the main CPU is running, the time is counted.
57
+ * This may include any kind of sleep mode, but may
58
+ * not include pure Wake on LAN. This value shall
59
+ * only increase during the lifetime of the Device
60
+ * and shall not be reset when the Device is
61
+ * restarted. The PowerOnDuration is provided as
62
+ * Duration, i.e., in milliseconds or even fractions
63
+ * of a millisecond. However, the Server is not
64
+ * expected to update the value in such a high
65
+ * frequency, but maybe once a minute or once an
66
+ * hour, depending on the application.
67
+ */
68
+ powerOnDuration?: UAProperty<number, DataType.Double>;
69
+ }
70
+ export interface UAGeneralDeviceConditionSet extends UAObject, UAGeneralDeviceConditionSet_Base {
71
+ }
@@ -0,0 +1,22 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { UAProperty } from "node-opcua-address-space-base"
3
+ import { DataType } from "node-opcua-variant"
4
+ import { EUInformation } from "node-opcua-data-access"
5
+ import { UABaseInterface, UABaseInterface_Base } from "node-opcua-nodeset-ua/source/ua_base_interface"
6
+ import { UAAnalogUnit } from "node-opcua-nodeset-ua/source/ua_analog_unit"
7
+ /**
8
+ * | | |
9
+ * |----------------|------------------------------------------------------------|
10
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
11
+ * |nodeClass |ObjectType |
12
+ * |typedDefinition |IAmperometricCalibrationType i=1048 |
13
+ * |isAbstract |true |
14
+ */
15
+ export interface UAIAmperometricCalibration_Base extends UABaseInterface_Base {
16
+ amperometricSensorSlope?: UAAnalogUnit<number, DataType.Float>;
17
+ amperometricSensorZeroPoint?: UAAnalogUnit<number, DataType.Float>;
18
+ absoluteAirPressure?: UAAnalogUnit<number, DataType.Float>;
19
+ sensorT90?: UAProperty<number, DataType.Float>;
20
+ }
21
+ export interface UAIAmperometricCalibration extends UABaseInterface, UAIAmperometricCalibration_Base {
22
+ }
@@ -0,0 +1,23 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { UAProperty } from "node-opcua-address-space-base"
3
+ import { DataType } from "node-opcua-variant"
4
+ import { EUInformation } from "node-opcua-data-access"
5
+ import { UInt32 } from "node-opcua-basic-types"
6
+ import { UABaseInterface, UABaseInterface_Base } from "node-opcua-nodeset-ua/source/ua_base_interface"
7
+ import { UAAnalogUnit } from "node-opcua-nodeset-ua/source/ua_analog_unit"
8
+ /**
9
+ * | | |
10
+ * |----------------|------------------------------------------------------------|
11
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
12
+ * |nodeClass |ObjectType |
13
+ * |typedDefinition |IAmperometricSignalConditionSetType i=1064 |
14
+ * |isAbstract |true |
15
+ */
16
+ export interface UAIAmperometricSignalConditionSet_Base extends UABaseInterface_Base {
17
+ sensorCleaningsCounter?: UAProperty<UInt32, DataType.UInt32>;
18
+ sensorNextCalibration?: UAAnalogUnit<UInt32, DataType.UInt32>;
19
+ sensorSterilisationsCounter?: UAProperty<UInt32, DataType.UInt32>;
20
+ sensingElementTemperature?: UAAnalogUnit<number, DataType.Float>;
21
+ }
22
+ export interface UAIAmperometricSignalConditionSet extends UABaseInterface, UAIAmperometricSignalConditionSet_Base {
23
+ }
@@ -0,0 +1,25 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { UAProperty } from "node-opcua-address-space-base"
3
+ import { DataType, VariantOptions } from "node-opcua-variant"
4
+ import { LocalizedText } from "node-opcua-data-model"
5
+ import { NodeId } from "node-opcua-nodeid"
6
+ import { UInt32 } from "node-opcua-basic-types"
7
+ import { DTEnumValue } from "node-opcua-nodeset-ua/source/dt_enum_value"
8
+ import { UABaseInterface, UABaseInterface_Base } from "node-opcua-nodeset-ua/source/ua_base_interface"
9
+ import { UAMultiStateDictionaryEntryDiscrete } from "node-opcua-nodeset-ua/source/ua_multi_state_dictionary_entry_discrete"
10
+ import { UACalibrationPointSet } from "./ua_calibration_point_set"
11
+ /**
12
+ * | | |
13
+ * |----------------|------------------------------------------------------------|
14
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
15
+ * |nodeClass |ObjectType |
16
+ * |typedDefinition |ICalibrationType i=1045 |
17
+ * |isAbstract |true |
18
+ */
19
+ export interface UAICalibration_Base extends UABaseInterface_Base {
20
+ calibrationPointSet?: UACalibrationPointSet;
21
+ calibrationTimestamp?: UAProperty<Date, DataType.DateTime>;
22
+ typeOfCalibration?: UAMultiStateDictionaryEntryDiscrete<UInt32, DataType.UInt32>;
23
+ }
24
+ export interface UAICalibration extends UABaseInterface, UAICalibration_Base {
25
+ }
@@ -0,0 +1,18 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { DataType } from "node-opcua-variant"
3
+ import { EUInformation } from "node-opcua-data-access"
4
+ import { UABaseInterface, UABaseInterface_Base } from "node-opcua-nodeset-ua/source/ua_base_interface"
5
+ import { UAAnalogUnit } from "node-opcua-nodeset-ua/source/ua_analog_unit"
6
+ /**
7
+ * | | |
8
+ * |----------------|------------------------------------------------------------|
9
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
10
+ * |nodeClass |ObjectType |
11
+ * |typedDefinition |IConductivityCalibrationType i=1047 |
12
+ * |isAbstract |true |
13
+ */
14
+ export interface UAIConductivityCalibration_Base extends UABaseInterface_Base {
15
+ conductivityCellConstant?: UAAnalogUnit<number, DataType.Float>;
16
+ }
17
+ export interface UAIConductivityCalibration extends UABaseInterface, UAIConductivityCalibration_Base {
18
+ }
@@ -0,0 +1,28 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { UAProperty } from "node-opcua-address-space-base"
3
+ import { DataType } from "node-opcua-variant"
4
+ import { LocalizedText } from "node-opcua-data-model"
5
+ import { EUInformation } from "node-opcua-data-access"
6
+ import { NodeId } from "node-opcua-nodeid"
7
+ import { UInt32 } from "node-opcua-basic-types"
8
+ import { DTEnumValue } from "node-opcua-nodeset-ua/source/dt_enum_value"
9
+ import { UABaseInterface, UABaseInterface_Base } from "node-opcua-nodeset-ua/source/ua_base_interface"
10
+ import { UAMultiStateDictionaryEntryDiscrete } from "node-opcua-nodeset-ua/source/ua_multi_state_dictionary_entry_discrete"
11
+ import { UAAnalogUnit } from "node-opcua-nodeset-ua/source/ua_analog_unit"
12
+ /**
13
+ * | | |
14
+ * |----------------|------------------------------------------------------------|
15
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
16
+ * |nodeClass |ObjectType |
17
+ * |typedDefinition |IConductivitySignalConditionSetType i=1062 |
18
+ * |isAbstract |true |
19
+ */
20
+ export interface UAIConductivitySignalConditionSet_Base extends UABaseInterface_Base {
21
+ conductivityMeasuringMethod?: UAMultiStateDictionaryEntryDiscrete<UInt32, DataType.UInt32>;
22
+ sensorCleaningsCounter?: UAProperty<UInt32, DataType.UInt32>;
23
+ sensorSterilisationsCounter?: UAProperty<UInt32, DataType.UInt32>;
24
+ sensingElementTemperature?: UAAnalogUnit<number, DataType.Float>;
25
+ temperatureCompensationStyle?: UAMultiStateDictionaryEntryDiscrete<UInt32, DataType.UInt32>;
26
+ }
27
+ export interface UAIConductivitySignalConditionSet extends UABaseInterface, UAIConductivitySignalConditionSet_Base {
28
+ }
@@ -0,0 +1,21 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { DataType } from "node-opcua-variant"
3
+ import { EUInformation } from "node-opcua-data-access"
4
+ import { UABaseInterface, UABaseInterface_Base } from "node-opcua-nodeset-ua/source/ua_base_interface"
5
+ import { UAAnalogUnit } from "node-opcua-nodeset-ua/source/ua_analog_unit"
6
+ /**
7
+ * | | |
8
+ * |----------------|------------------------------------------------------------|
9
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
10
+ * |nodeClass |ObjectType |
11
+ * |typedDefinition |IFlameIonisationDeviceConditionSetType i=1054 |
12
+ * |isAbstract |true |
13
+ */
14
+ export interface UAIFlameIonisationDeviceConditionSet_Base extends UABaseInterface_Base {
15
+ blockTemperature?: UAAnalogUnit<number, DataType.Float>;
16
+ catalystTemperature?: UAAnalogUnit<number, DataType.Float>;
17
+ combustionAirPressure?: UAAnalogUnit<number, DataType.Float>;
18
+ fuelGasPressure?: UAAnalogUnit<number, DataType.Float>;
19
+ }
20
+ export interface UAIFlameIonisationDeviceConditionSet extends UABaseInterface, UAIFlameIonisationDeviceConditionSet_Base {
21
+ }
@@ -0,0 +1,22 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { UAObject } from "node-opcua-address-space-base"
3
+ import { DataType, VariantOptions } from "node-opcua-variant"
4
+ import { EUInformation } from "node-opcua-data-access"
5
+ import { UAString } from "node-opcua-basic-types"
6
+ import { DTRange } from "node-opcua-nodeset-ua/source/dt_range"
7
+ import { UABaseInterface, UABaseInterface_Base } from "node-opcua-nodeset-ua/source/ua_base_interface"
8
+ import { UAGeneralDeviceConditionSet } from "./ua_general_device_condition_set"
9
+ /**
10
+ * | | |
11
+ * |----------------|------------------------------------------------------------|
12
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
13
+ * |nodeClass |ObjectType |
14
+ * |typedDefinition |IGeneralDeviceConditionSetType i=1044 |
15
+ * |isAbstract |true |
16
+ */
17
+ export interface UAIGeneralDeviceConditionSet_Base extends UABaseInterface_Base {
18
+ generalDeviceConditions?: UAGeneralDeviceConditionSet;
19
+ deviceComponentConditions?: UAObject;
20
+ }
21
+ export interface UAIGeneralDeviceConditionSet extends UABaseInterface, UAIGeneralDeviceConditionSet_Base {
22
+ }
@@ -0,0 +1,23 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { UAProperty } from "node-opcua-address-space-base"
3
+ import { DataType } from "node-opcua-variant"
4
+ import { EUInformation } from "node-opcua-data-access"
5
+ import { UABaseInterface, UABaseInterface_Base } from "node-opcua-nodeset-ua/source/ua_base_interface"
6
+ import { UAAnalogUnit } from "node-opcua-nodeset-ua/source/ua_analog_unit"
7
+ import { UABaseAnalog } from "node-opcua-nodeset-ua/source/ua_base_analog"
8
+ /**
9
+ * | | |
10
+ * |----------------|------------------------------------------------------------|
11
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
12
+ * |nodeClass |ObjectType |
13
+ * |typedDefinition |INonDispersiveInfraredSignalConditionSetType i=1055 |
14
+ * |isAbstract |true |
15
+ */
16
+ export interface UAINonDispersiveInfraredSignalConditionSet_Base extends UABaseInterface_Base {
17
+ absoluteSampleGasPressure?: UAAnalogUnit<number, DataType.Float>;
18
+ chopperFrequencyDeviation?: UABaseAnalog<number, DataType.Float>;
19
+ sampleCellTemperature?: UAAnalogUnit<number, DataType.Float>;
20
+ sourceResidualLife?: UAProperty<number, DataType.Float>;
21
+ }
22
+ export interface UAINonDispersiveInfraredSignalConditionSet extends UABaseInterface, UAINonDispersiveInfraredSignalConditionSet_Base {
23
+ }
@@ -0,0 +1,22 @@
1
+ // ----- this file has been automatically generated - do not edit
2
+ import { UAProperty } from "node-opcua-address-space-base"
3
+ import { DataType } from "node-opcua-variant"
4
+ import { EUInformation } from "node-opcua-data-access"
5
+ import { UABaseInterface, UABaseInterface_Base } from "node-opcua-nodeset-ua/source/ua_base_interface"
6
+ import { UAAnalogUnit } from "node-opcua-nodeset-ua/source/ua_analog_unit"
7
+ /**
8
+ * | | |
9
+ * |----------------|------------------------------------------------------------|
10
+ * |namespace |http://opcfoundation.org/UA/PADIM/ |
11
+ * |nodeClass |ObjectType |
12
+ * |typedDefinition |IOpticalFluorescenseQuenchingCalibrationType i=1049 |
13
+ * |isAbstract |true |
14
+ */
15
+ export interface UAIOpticalFluorescenseQuenchingCalibration_Base extends UABaseInterface_Base {
16
+ absoluteAirPressure?: UAAnalogUnit<number, DataType.Float>;
17
+ opticalFluorescenseQuenchingSensorSlope?: UAAnalogUnit<number, DataType.Float>;
18
+ opticalFluorescenseQuenchingSensorZeroPoint?: UAAnalogUnit<number, DataType.Float>;
19
+ sensorT90?: UAProperty<number, DataType.Float>;
20
+ }
21
+ export interface UAIOpticalFluorescenseQuenchingCalibration extends UABaseInterface, UAIOpticalFluorescenseQuenchingCalibration_Base {
22
+ }