This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/.agents/handoffs/compressed-air-desktop-migration.md +4 -0
- package/bin/client.wasm +0 -0
- package/bin/package.json +1 -1
- package/bin/ts_def_modules/compressedAir/assessment/compressor_system_profile.d.ts +2 -0
- package/build-wasm/bin/client.wasm +0 -0
- package/docs/dox-content/calculators/compressedAir/assessment/compressor_system_profile.dox +13 -4
- package/package.json +1 -1
- package/ts_def/ts_def_modules/compressedAir/assessment/compressor_system_profile.d.ts +2 -0
|
@@ -106,12 +106,16 @@
|
|
|
106
106
|
- `calculateBaselineProfile(compressors, profileRows, options): CompressorProfileRowV`
|
|
107
107
|
- Inputs: `CompressorProfileCompressorV`, `CompressorProfileRowV`, `CompressorProfileOptions`.
|
|
108
108
|
- Outputs: registered vector of calculated compressor rows. Caller must call `delete()`.
|
|
109
|
+
- `CompressorProfileCompressor.unloadPointCapacityPct`
|
|
110
|
+
- Map from Desktop `compressor.compressorControls.unloadPointCapacity`.
|
|
111
|
+
- Units: percent. Pass zero only when Suite should derive the value from the unload airflow and full-load airflow points.
|
|
109
112
|
- `calculateProfileTotals(compressors, profileRows): CompressorProfileTotalV`
|
|
110
113
|
- Inputs: compressor vector, calculated row vector.
|
|
111
114
|
- Outputs: registered vector of total rows. Caller must call `delete()`.
|
|
112
115
|
- `reallocateProfileFlow(compressors, previousProfileRows, demandRows, options, runtimeStates, trimSelections): CompressorProfileRowV`
|
|
113
116
|
- Inputs: compressor vector, prior row vector, demand total vector, options, runtime state vector, trim selection vector.
|
|
114
117
|
- Outputs: registered vector of adjusted compressor rows. Caller must call `delete()`.
|
|
118
|
+
- Base-trim mode uses `trimSelections` to select the trim compressor. If demand is within trim capacity, only the trim compressor runs. When demand exceeds trim capacity, Suite selects the smallest base-compressor set that covers the excess over trim capacity, chooses the lowest full-load power combination within that size, evaluates selected bases before the trim compressor, and recalculates a selected base below full load if full load would exceed remaining demand. The trim compressor is evaluated last and receives any remaining airflow.
|
|
115
119
|
- `calculateProfileSavings(baselineRows, adjustedRows, input): CompressorProfileSavingsResult`
|
|
116
120
|
- Inputs: baseline row vector, adjusted row vector, electricity cost dollars/kWh, interval hours, operating days, auxiliary energy kWh/year, implementation cost dollars, salvage dollars.
|
|
117
121
|
- Outputs: annual baseline/adjusted energy kWh, annual baseline/adjusted cost dollars, energy savings kWh, cost savings dollars, percent savings, payback months.
|
package/bin/client.wasm
CHANGED
|
Binary file
|
package/bin/package.json
CHANGED
|
@@ -43,6 +43,8 @@ export interface CompressorProfileCompressor {
|
|
|
43
43
|
blowdownTimeSec: number;
|
|
44
44
|
/** Unload sump pressure, units psig. */
|
|
45
45
|
unloadSumpPressurePsig: number;
|
|
46
|
+
/** Explicit unload capacity, units percent; pass zero to derive from performance points. */
|
|
47
|
+
unloadPointCapacityPct: number;
|
|
46
48
|
/** Modulation floor fraction, dimensionless. */
|
|
47
49
|
noLoadPowerFractionForModulation: number;
|
|
48
50
|
/** Modulating pressure range, units psig. */
|
|
Binary file
|
|
@@ -55,7 +55,9 @@
|
|
|
55
55
|
* point is treated as the standard 100 percent unload-capacity setting. This keeps
|
|
56
56
|
* the cycle model anchored at full-load airflow when the assessment has no separate
|
|
57
57
|
* unload-point airflow value, rather than interpreting the missing point as zero
|
|
58
|
-
* unload capacity.
|
|
58
|
+
* unload capacity. When an assessment supplies an explicit unload-capacity setting,
|
|
59
|
+
* that percentage is used directly; otherwise the percentage is derived from the
|
|
60
|
+
* unload airflow point and the full-load airflow point.
|
|
59
61
|
*
|
|
60
62
|
* @formula{compressor-profile-system-airflow-fraction;
|
|
61
63
|
* f_{Q,sys,i} = \frac{Q_i}{\sum_j Q_{FL,j}}
|
|
@@ -112,9 +114,16 @@
|
|
|
112
114
|
* @details Load-sharing operation looks at the available compressor combinations that can meet
|
|
113
115
|
* the requested demand and selects the combination with the lowest total package
|
|
114
116
|
* power. The selected compressors split demand equally where possible. Base-trim
|
|
115
|
-
* operation keeps a selected trim compressor available for each day type
|
|
116
|
-
*
|
|
117
|
-
*
|
|
117
|
+
* operation keeps a selected trim compressor available for each day type. The trim
|
|
118
|
+
* compressor is the adjustable compressor. If the requested airflow is within trim
|
|
119
|
+
* capacity, only the trim compressor runs. When demand exceeds trim capacity, the
|
|
120
|
+
* algorithm finds the smallest number of base compressors that can cover the excess
|
|
121
|
+
* airflow over trim capacity, then chooses the lowest full-load power combination
|
|
122
|
+
* within that size. The selected base compressors are evaluated before the trim
|
|
123
|
+
* compressor. Each selected base is first tried at full load, but if that would
|
|
124
|
+
* exceed the remaining demand, that base compressor is recalculated at the smaller
|
|
125
|
+
* remaining airflow. The trim compressor is evaluated last and supplies any
|
|
126
|
+
* remaining airflow.
|
|
118
127
|
*
|
|
119
128
|
* @formula{compressor-profile-combination-power;
|
|
120
129
|
* P_{combo} = \sum_{i \in S} P_i(Q_i)
|
package/package.json
CHANGED
|
@@ -43,6 +43,8 @@ export interface CompressorProfileCompressor {
|
|
|
43
43
|
blowdownTimeSec: number;
|
|
44
44
|
/** Unload sump pressure, units psig. */
|
|
45
45
|
unloadSumpPressurePsig: number;
|
|
46
|
+
/** Explicit unload capacity, units percent; pass zero to derive from performance points. */
|
|
47
|
+
unloadPointCapacityPct: number;
|
|
46
48
|
/** Modulation floor fraction, dimensionless. */
|
|
47
49
|
noLoadPowerFractionForModulation: number;
|
|
48
50
|
/** Modulating pressure range, units psig. */
|