measur-tools-suite 1.0.14-rc.20 → 1.0.14-rc.22
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/bin/client.wasm
CHANGED
|
Binary file
|
package/bin/package.json
CHANGED
|
@@ -0,0 +1,40 @@
|
|
|
1
|
+
/**
|
|
2
|
+
* @defgroup energy_input_electric_arc_furnace_calculator Energy Input Electric Arc Furnace Calculator
|
|
3
|
+
* @ingroup heat_loss_calculators
|
|
4
|
+
* @brief Calculates total energy input and heat delivered for electric arc furnaces (EAF).
|
|
5
|
+
* @details This calculator estimates the total chemical energy input and total heat delivered to an EAF, including contributions from natural gas, coal/carbon injection, electrodes, other fuels, and electricity. It uses standard unit conversions and accounts for all major energy sources supplied to the furnace. Relevant formulas are documented below.
|
|
6
|
+
*
|
|
7
|
+
* @heading{Total Chemical Energy Input}
|
|
8
|
+
* @copydoc energy_input_electric_arc_furnace_formula
|
|
9
|
+
*
|
|
10
|
+
* @heading{Total Heat Delivered}
|
|
11
|
+
* @copydoc energy_input_electric_arc_furnace_heat_delivered_formula
|
|
12
|
+
*/
|
|
13
|
+
|
|
14
|
+
/**
|
|
15
|
+
* @defgroup energy_input_electric_arc_furnace_formula Energy Input Electric Arc Furnace Formula
|
|
16
|
+
* @ingroup energy_input_electric_arc_furnace_calculator
|
|
17
|
+
* @formula{eaf-chemical-energy-input; Q_\text{chem} = Q_\text{ng} + m_\text{coal} c_\text{coal} + m_\text{elec} c_\text{elec} + Q_\text{other}}
|
|
18
|
+
* @subheading{Symbols}
|
|
19
|
+
* @symtable
|
|
20
|
+
* @symrow{Q_\text{chem}; Total chemical energy input; \btu\per\hour}
|
|
21
|
+
* @symrow{Q_\text{ng}; Natural gas heat input; \btu\per\hour}
|
|
22
|
+
* @symrow{m_\text{coal}; Mass of coal/carbon injection; \pound\per\hour}
|
|
23
|
+
* @symrow{c_\text{coal}; Heating value of coal/carbon; \btu\per\pound}
|
|
24
|
+
* @symrow{m_\text{elec}; Electrode use; \pound\per\hour}
|
|
25
|
+
* @symrow{c_\text{elec}; Electrode heating value; \btu\per\pound}
|
|
26
|
+
* @symrow{Q_\text{other}; Other fuel heat input; \btu\per\hour}
|
|
27
|
+
* @endsymtable
|
|
28
|
+
*/
|
|
29
|
+
|
|
30
|
+
/**
|
|
31
|
+
* @defgroup energy_input_electric_arc_furnace_heat_delivered_formula Energy Input Electric Arc Furnace Heat Delivered Formula
|
|
32
|
+
* @ingroup energy_input_electric_arc_furnace_calculator
|
|
33
|
+
* @formula{eaf-heat-delivered; Q_\text{delivered} = Q_\text{chem} + Q_\text{elec}}
|
|
34
|
+
* @subheading{Symbols}
|
|
35
|
+
* @symtable
|
|
36
|
+
* @symrow{Q_\text{delivered}; Total heat delivered to EAF; \btu\per\hour}
|
|
37
|
+
* @symrow{Q_\text{chem}; Total chemical energy input; \btu\per\hour}
|
|
38
|
+
* @symrow{Q_\text{elec}; Electric power supplied; \kilowatt\hour\per\hour}
|
|
39
|
+
* @endsymtable
|
|
40
|
+
*/
|
|
@@ -0,0 +1,77 @@
|
|
|
1
|
+
/**
|
|
2
|
+
* @defgroup exhaust_gas_heat_loss_electric_arc_furnace_calculator Exhaust Gas Heat Loss Calculation (Electric Arc Furnace)
|
|
3
|
+
* @ingroup heat_loss_calculators
|
|
4
|
+
* @brief Calculates total heat loss from exhaust gas in electric arc furnaces (EAF).
|
|
5
|
+
* @details The following formulas describe the calculation of heat loss from exhaust gases, including chemical heat, total heat value per unit volume, corrected volume flow rate, and total heat loss. Each step is documented with its own formula and symbol table.
|
|
6
|
+
*
|
|
7
|
+
* @heading{Total Heat Loss}
|
|
8
|
+
* @copydoc exhaust_gas_total_heat_loss_cpp_formula
|
|
9
|
+
*
|
|
10
|
+
* @heading{Corrected Volume Flow Rate}
|
|
11
|
+
* @copydoc exhaust_gas_total_vfr_cpp_formula
|
|
12
|
+
*
|
|
13
|
+
* @heading{Total Heat Value per Unit Volume}
|
|
14
|
+
* @copydoc exhaust_gas_total_heat_value_cpp_formula
|
|
15
|
+
*
|
|
16
|
+
* @heading{Chemical Heat}
|
|
17
|
+
* @copydoc exhaust_gas_chemical_heat_cpp_formula
|
|
18
|
+
*
|
|
19
|
+
*/
|
|
20
|
+
|
|
21
|
+
/**
|
|
22
|
+
* @defgroup exhaust_gas_chemical_heat_cpp_formula Chemical Heat Formula
|
|
23
|
+
* @ingroup exhaust_gas_heat_loss_electric_arc_furnace_calculator
|
|
24
|
+
* @formula{exhaust-gas-chemical-heat-cpp; Q_{chem} = \frac{CO \cdot 321 + H_{2} \cdot 325 + Combustibles \cdot 1020}{100}}
|
|
25
|
+
* @subheading{Symbols}
|
|
26
|
+
* @symtable
|
|
27
|
+
* @symrow{Q_{chem}; Chemical heat per unit volume; \btu}
|
|
28
|
+
* @symrow{CO; Percent CO in exhaust gas; \percent}
|
|
29
|
+
* @symrow{H_{2}; Percent @math{H_2} in exhaust gas; \percent}
|
|
30
|
+
* @symrow{Combustibles; Percent other combustibles in exhaust gas; \percent}
|
|
31
|
+
* @symrow{321; Heating value for CO; \btu\per\percent}
|
|
32
|
+
* @symrow{325; Heating value for @math{H_2}; \btu\per\percent}
|
|
33
|
+
* @symrow{1020; Heating value for other combustibles; \btu\per\percent}
|
|
34
|
+
* @endsymtable
|
|
35
|
+
*/
|
|
36
|
+
|
|
37
|
+
/**
|
|
38
|
+
* @defgroup exhaust_gas_total_heat_value_cpp_formula Total Heat Value per Unit Volume Formula
|
|
39
|
+
* @ingroup exhaust_gas_heat_loss_electric_arc_furnace_calculator
|
|
40
|
+
* @formula{exhaust-gas-total-heat-value-cpp; Q_{flue} = Q_{chem} + 0.0225 \cdot (T_{gas} - T_{ambient}) + Dust_{loading} \cdot 0.25 \cdot (T_{gas} - T_{ambient})}
|
|
41
|
+
* @subheading{Symbols}
|
|
42
|
+
* @symtable
|
|
43
|
+
* @symrow{Q_{flue}; Total heat value per unit volume; \btu}
|
|
44
|
+
* @symrow{Q_{chem}; Chemical heat per unit volume; \btu}
|
|
45
|
+
* @symrow{0.0225; Sensible heat factor; \btu\per\degreeFahrenheit}
|
|
46
|
+
* @symrow{T_{gas}; Exhaust gas temperature; \degreeFahrenheit}
|
|
47
|
+
* @symrow{T_{ambient}; Ambient/reference temperature; \degreeFahrenheit}
|
|
48
|
+
* @symrow{Dust_{loading}; Dust loading in exhaust gas; \pound\per\cubic\foot}
|
|
49
|
+
* @symrow{0.25; Dust heat factor; \btu\per\degreeFahrenheit}
|
|
50
|
+
* @endsymtable
|
|
51
|
+
*/
|
|
52
|
+
|
|
53
|
+
/**
|
|
54
|
+
* @defgroup exhaust_gas_total_vfr_cpp_formula Corrected Volume Flow Rate Formula
|
|
55
|
+
* @ingroup exhaust_gas_heat_loss_electric_arc_furnace_calculator
|
|
56
|
+
* @formula{exhaust-gas-total-vfr-cpp; VFR_{total} = VFR_{measured} \cdot \frac{T_{std}}{460 + T_{gas}}}
|
|
57
|
+
* @subheading{Symbols}
|
|
58
|
+
* @symtable
|
|
59
|
+
* @symrow{VFR_{total}; Corrected volume flow rate; \ft\cubed\per\minute}
|
|
60
|
+
* @symrow{VFR_{measured}; Measured volume flow rate; \ft\cubed\per\minute}
|
|
61
|
+
* @symrow{T_{std}; Standard gas temperature (520 °F); \degreeFahrenheit}
|
|
62
|
+
* @symrow{T_{gas}; Exhaust gas temperature; \degreeFahrenheit}
|
|
63
|
+
* @endsymtable
|
|
64
|
+
*/
|
|
65
|
+
|
|
66
|
+
/**
|
|
67
|
+
* @defgroup exhaust_gas_total_heat_loss_cpp_formula Total Heat Loss Formula
|
|
68
|
+
* @ingroup exhaust_gas_heat_loss_electric_arc_furnace_calculator
|
|
69
|
+
* @formula{exhaust-gas-total-heat-loss-cpp; Q_{total} = VFR_{total} \cdot Q_{flue} \cdot 60}
|
|
70
|
+
* @subheading{Symbols}
|
|
71
|
+
* @symtable
|
|
72
|
+
* @symrow{Q_{total}; Total heat loss; \btu\per\hour}
|
|
73
|
+
* @symrow{VFR_{total}; Corrected volume flow rate; \ft\cubed\per\minute}
|
|
74
|
+
* @symrow{Q_{flue}; Total heat value per unit volume; \btu}
|
|
75
|
+
* @symrow{60; Minutes per hour; \minute\per\hour}
|
|
76
|
+
* @endsymtable
|
|
77
|
+
*/
|