This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/bin/client.wasm
CHANGED
|
Binary file
|
package/bin/package.json
CHANGED
|
@@ -0,0 +1,56 @@
|
|
|
1
|
+
/**
|
|
2
|
+
* @defgroup energy_equivalency_calculator Energy Equivalency Calculator
|
|
3
|
+
* @ingroup process_heat_calculators
|
|
4
|
+
* @brief Calculates equivalent heat input for electrical and fuel-fired furnaces.
|
|
5
|
+
* @details This calculator estimates the equivalent heat input required when switching between fuel-fired and electrically heated furnaces. The calculation uses process heat input and equipment efficiencies. Methods are based on standard industrial practice for process heating systems.
|
|
6
|
+
*
|
|
7
|
+
* The calculation follows:
|
|
8
|
+
* 1. **Electrical Equivalent Heat Input** - Calculate the electrical heat input required to replace a fuel-fired furnace
|
|
9
|
+
* 2. **Fuel-Fired Equivalent Heat Input** - Calculate the fuel-fired heat input required to replace an electrically heated furnace
|
|
10
|
+
*
|
|
11
|
+
* Relevant formulas and symbol definitions are documented below.
|
|
12
|
+
*
|
|
13
|
+
* @heading{Electrical Equivalent Heat Input}
|
|
14
|
+
* @copydoc energy_equivalency_electrical_formula
|
|
15
|
+
*
|
|
16
|
+
* @heading{Fuel-Fired Equivalent Heat Input}
|
|
17
|
+
* @copydoc energy_equivalency_fuel_fired_formula
|
|
18
|
+
*/
|
|
19
|
+
|
|
20
|
+
/**
|
|
21
|
+
* @defgroup energy_equivalency_electrical_formula Electrical Equivalent Heat Input Formula
|
|
22
|
+
* @ingroup energy_equivalency_calculator
|
|
23
|
+
* @brief Calculates the electrical heat input required to replace a fuel-fired furnace.
|
|
24
|
+
* @details The equivalent electrical heat input is calculated as:
|
|
25
|
+
*
|
|
26
|
+
* @formula{energy-equivalency-electrical; P_{elec} = \frac{P_{fuel} \cdot \eta_{fuel}}{\eta_{elec}}}
|
|
27
|
+
*
|
|
28
|
+
* @subheading{Symbols}
|
|
29
|
+
* @symtable
|
|
30
|
+
* @symrow{P_{elec}; Equivalent electrical heat input; \kilo\watt}
|
|
31
|
+
* @symrow{P_{fuel}; Fuel-fired heat input; \mega\btu\per\hour}
|
|
32
|
+
* @symrow{\eta_{fuel}; Fuel-fired furnace efficiency; \percent}
|
|
33
|
+
* @symrow{\eta_{elec}; Electrically heated furnace efficiency; \percent}
|
|
34
|
+
* @endsymtable
|
|
35
|
+
*
|
|
36
|
+
* @note The result is converted from MMBtu/hr to kW using the factor 1 MMBtu/hr = 293.07107 kW.
|
|
37
|
+
*/
|
|
38
|
+
|
|
39
|
+
/**
|
|
40
|
+
* @defgroup energy_equivalency_fuel_fired_formula Fuel-Fired Equivalent Heat Input Formula
|
|
41
|
+
* @ingroup energy_equivalency_calculator
|
|
42
|
+
* @brief Calculates the fuel-fired heat input required to replace an electrically heated furnace.
|
|
43
|
+
* @details The equivalent fuel-fired heat input is calculated as:
|
|
44
|
+
*
|
|
45
|
+
* @formula{energy-equivalency-fuel-fired; P_{fuel} = \frac{P_{elec} \cdot \eta_{elec}}{\eta_{fuel}}}
|
|
46
|
+
*
|
|
47
|
+
* @subheading{Symbols}
|
|
48
|
+
* @symtable
|
|
49
|
+
* @symrow{P_{fuel}; Equivalent fuel-fired heat input; \mega\btu\per\hour}
|
|
50
|
+
* @symrow{P_{elec}; Electrical heat input; \kilo\watt}
|
|
51
|
+
* @symrow{\eta_{elec}; Electrically heated furnace efficiency; \percent}
|
|
52
|
+
* @symrow{\eta_{fuel}; Fuel-fired furnace efficiency; \percent}
|
|
53
|
+
* @endsymtable
|
|
54
|
+
*
|
|
55
|
+
* @note The result is converted from kW to MMBtu/hr using the factor 1 kW = 0.003412142 MMBtu/hr.
|
|