This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/bin/package.json
CHANGED
|
@@ -35,6 +35,7 @@
|
|
|
35
35
|
/**
|
|
36
36
|
* @defgroup liquid_load_charge_material_sensible_heat_cpp_formula Sensible Heat (Below Vaporizing Temp) Formula
|
|
37
37
|
* @ingroup liquid_load_charge_material_heat_required_calculator
|
|
38
|
+
* @details The total heat required when discharge temperature is below vaporizing temperature.
|
|
38
39
|
* @formula{liquid-load-charge-material-sensible-heat-cpp; Q_{liq} = m_{feed} \cdot C_{p,liq} \cdot (T_{discharge} - T_{initial})}
|
|
39
40
|
* @subheading{Symbols}
|
|
40
41
|
* @symtable
|
|
@@ -49,23 +50,14 @@
|
|
|
49
50
|
/**
|
|
50
51
|
* @defgroup liquid_load_charge_material_full_heat_cpp_formula Full Heating (Above Vaporizing Temp) Formula
|
|
51
52
|
* @ingroup liquid_load_charge_material_heat_required_calculator
|
|
52
|
-
* @details The total heat required when discharge temperature is above vaporizing temperature
|
|
53
|
+
* @details The total heat required when discharge temperature is above vaporizing temperature.
|
|
53
54
|
*
|
|
54
|
-
*
|
|
55
|
+
* @formula{liquid-load-charge-material-full-heat-cpp; Q_{liq} = Q_{sens,liq} + Q_{vap} + Q_{sens,vapor} + Q_{sens,remliq}}
|
|
55
56
|
* @formula{liquid-load-charge-material-sensible-heat-to-vaporizing-cpp; Q_{sens,liq} = m_{feed} \cdot C_{p,liq} \cdot (T_{vaporizing} - T_{initial})}
|
|
56
|
-
*
|
|
57
|
-
* Step 2: Vaporization heat for vaporized fraction:
|
|
58
57
|
* @formula{liquid-load-charge-material-vaporization-heat-cpp; Q_{vap} = m_{feed} \cdot f_{vaporized} \cdot H_{latent}}
|
|
59
|
-
*
|
|
60
|
-
* Step 3: Sensible heat for vaporized fraction (vapor):
|
|
61
58
|
* @formula{liquid-load-charge-material-sensible-heat-vapor-cpp; Q_{sens,vapor} = m_{feed} \cdot f_{vaporized} \cdot C_{p,vapor} \cdot (T_{discharge} - T_{vaporizing})}
|
|
62
|
-
*
|
|
63
|
-
* Step 4: Sensible heat for remaining liquid fraction:
|
|
64
59
|
* @formula{liquid-load-charge-material-sensible-heat-remaining-liq-cpp; Q_{sens,remliq} = m_{feed} \cdot (1-f_{vaporized}) \cdot C_{p,liq} \cdot (T_{discharge} - T_{vaporizing})}
|
|
65
60
|
*
|
|
66
|
-
* Step 5: Sum all heat contributions:
|
|
67
|
-
* @formula{liquid-load-charge-material-full-heat-cpp; Q_{liq} = Q_{sens,liq} + Q_{vap} + Q_{sens,vapor} + Q_{sens,remliq}}
|
|
68
|
-
*
|
|
69
61
|
* @subheading{Symbols}
|
|
70
62
|
* @symtable
|
|
71
63
|
* @symrow{Q_{liq}; Heat required for liquid heating/vaporization; \btu\per\hour}
|