This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/bin/client.wasm
CHANGED
|
Binary file
|
package/bin/package.json
CHANGED
|
@@ -0,0 +1,29 @@
|
|
|
1
|
+
/**
|
|
2
|
+
* @defgroup fixture_heat_loss_calculator Fixture Heat Loss Calculator
|
|
3
|
+
* @ingroup heat_loss_calculators
|
|
4
|
+
* @brief Calculates heat losses from fixtures, trays, and conveyors in process heating equipment.
|
|
5
|
+
* @details This calculator is used to estimate heat losses of process heating equipment due to fixtures, trays,
|
|
6
|
+
* conveyor belts, and similar equipment that enter the furnace at lower temperatures and are heated to the furnace
|
|
7
|
+
* temperature. These fixtures absorb heat from the furnace as they are heated from their initial temperature to the
|
|
8
|
+
* final furnace temperature. The calculator computes the total heat loss based on the feed rate, specific heat of the
|
|
9
|
+
* fixture material, initial and final temperatures, and a correction factor @cite trinks2003industrial. The calculation
|
|
10
|
+
* assumes there is no melting or phase change of the fixture material involved. Relevant formulas are documented below.
|
|
11
|
+
*
|
|
12
|
+
* @heading{Heat Loss}
|
|
13
|
+
* @copydoc fixture_heat_loss_formula
|
|
14
|
+
*/
|
|
15
|
+
|
|
16
|
+
/**
|
|
17
|
+
* @defgroup fixture_heat_loss_formula Fixture Heat Loss Formula
|
|
18
|
+
* @ingroup fixture_heat_loss_calculator
|
|
19
|
+
* @formula{fixture-heat-loss; Q = \dot{m} \cdot c_p \cdot (T_\text{final} - T_\text{initial}) \cdot f_\text{corr}}
|
|
20
|
+
* @subheading{Symbols}
|
|
21
|
+
* @symtable
|
|
22
|
+
* @symrow{Q; Heat loss; \btu\per\hour}
|
|
23
|
+
* @symrow{\dot{m}; Feed rate of fixture material; \pound\per\hour}
|
|
24
|
+
* @symrow{c_p; Specific heat of fixture material; \btu\per\pound\degreeFahrenheit}
|
|
25
|
+
* @symrow{T_\text{final}; Final temperature of fixture; \degreeFahrenheit}
|
|
26
|
+
* @symrow{T_\text{initial}; Initial temperature of fixture; \degreeFahrenheit}
|
|
27
|
+
* @symrow{f_\text{corr}; Correction factor; \unitless}
|
|
28
|
+
* @endsymtable
|
|
29
|
+
*/
|
|
@@ -1,4 +1,37 @@
|
|
|
1
1
|
/**
|
|
2
2
|
* @defgroup leakage_heat_loss_calculator Leakage Heat Loss Calculator
|
|
3
3
|
* @ingroup heat_loss_calculators
|
|
4
|
+
* @brief Calculates heat losses from hot gas leakage in process heating equipment.
|
|
5
|
+
* @details This calculator estimates the heat loss due to hot gases escaping from a furnace through openings other than the flue, under positive pressure conditions. The calculation uses furnace draft pressure, opening area, gas and ambient temperatures, a coefficient of discharge, specific gravity, and a correction factor. The method is based on standard industrial practice and is suitable for furnaces operating at positive pressure. Relevant formulas and symbol definitions are documented below.
|
|
6
|
+
*
|
|
7
|
+
* @heading{Leakage Heat Loss}
|
|
8
|
+
* @copydoc leakage_heat_loss_formula
|
|
9
|
+
*/
|
|
10
|
+
|
|
11
|
+
/**
|
|
12
|
+
* @defgroup leakage_heat_loss_formula Leakage Heat Loss Formula
|
|
13
|
+
* @ingroup leakage_heat_loss_calculator
|
|
14
|
+
* @formula{leakage-heat-loss; Q = c_{psv} \cdot \text{SCFH} \cdot (T_{\text{leak}} - T_{\text{amb}})}
|
|
15
|
+
* @formula{leakage-cpsv; c_{psv} = 0.0793 \cdot c_{pm}}
|
|
16
|
+
* @formula{leakage-cpm; c_{pm} = 0.2371 - 9 \times 10^{-6} \cdot T_{\text{midpoint}} + 7 \times 10^{-8} \cdot T_{\text{midpoint}}^2 - 3 \times 10^{-11} \cdot T_{\text{midpoint}}^3}
|
|
17
|
+
* @formula{leakage-midpoint; T_{\text{midpoint}} = \frac{T_{\text{leak}} + T_{\text{amb}}}{2}}
|
|
18
|
+
* @formula{leakage-scfh; \text{SCFH} = \text{CFH} \cdot \sqrt{\frac{520}{460 + T_{\text{leak}}}}}
|
|
19
|
+
* @formula{leakage-cfh; \text{CFH} = 1655 \cdot C_{d} \cdot f_{\text{corr}} \cdot (A \cdot 144) \cdot \sqrt{\frac{P}{SG}}}
|
|
20
|
+
* @subheading{Where:}
|
|
21
|
+
* @symtable
|
|
22
|
+
* @symrow{Q; Heat loss; \btu\per\hour}
|
|
23
|
+
* @symrow{c_{psv}; Specific heat of gas at average temperature; \btu\per\cubicFoot\degreeFahrenheit}
|
|
24
|
+
* @symrow{c_{pm}; Specific heat of gas at midpoint temperature; \btu\per\pound\degreeFahrenheit}
|
|
25
|
+
* @symrow{T_{\text{midpoint}}; Midpoint temperature; \degreeFahrenheit}
|
|
26
|
+
* @symrow{T_{\text{amb}}; Ambient temperature; \degreeFahrenheit}
|
|
27
|
+
* @symrow{T_{\text{leak}}; Temperature of leaking gases; \degreeFahrenheit}
|
|
28
|
+
* @symrow{\text{SCFH}; Standard cubic feet per hour of leakage; \cubicFoot\per\hour}
|
|
29
|
+
* @symrow{SG; Specific gravity of gas; \unitless}
|
|
30
|
+
* @symrow{P; Furnace draft pressure; \inchWaterColumn}
|
|
31
|
+
* @symrow{A; Opening area; \foot\squared}
|
|
32
|
+
* @symrow{f_{\text{corr}}; Correction factor; \unitless}
|
|
33
|
+
* @symrow{C_{d}; Coefficient of discharge or flow coefficient; \unitless}
|
|
34
|
+
* @symrow{\text{CFH}; Volumetric flow rate of leakage; \cubicFoot\per\hour}
|
|
35
|
+
* @endsymtable
|
|
36
|
+
* @note The coefficient of discharge depends on the angle of convergence in degrees. (Source: Eclipse Combustion Engineering Guide, 1986, Chapter 1, Page #6) [PDF link](https://www.mathscinotes.com/wp-content/uploads/2014/12/Eclipse-Engineering-Guide.pdf)
|
|