jsthermalcomfort 0.0.2 → 0.1.2

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (228) hide show
  1. package/README.md +196 -6
  2. package/lib/cjs/index.js +7 -434
  3. package/lib/cjs/models/a_pmv.js +140 -0
  4. package/lib/cjs/models/adaptive_ashrae.js +290 -0
  5. package/lib/cjs/models/adaptive_en.js +300 -0
  6. package/lib/cjs/models/ankle_draft.js +82 -0
  7. package/lib/cjs/models/at.js +52 -0
  8. package/lib/cjs/models/athb.js +135 -0
  9. package/lib/cjs/models/clo_tout.js +58 -0
  10. package/lib/cjs/models/cooling_effect.js +164 -0
  11. package/lib/cjs/models/discomfort_index.js +115 -0
  12. package/lib/cjs/models/e_pmv.js +154 -0
  13. package/lib/cjs/models/heat_index.js +60 -0
  14. package/lib/cjs/models/humidex.js +63 -0
  15. package/lib/cjs/models/index.js +71 -0
  16. package/lib/cjs/models/net.js +50 -0
  17. package/lib/cjs/models/pet_steady.js +443 -0
  18. package/lib/cjs/models/phs.js +458 -0
  19. package/lib/cjs/models/pmv.js +200 -0
  20. package/lib/cjs/models/pmv_ppd.js +404 -0
  21. package/lib/cjs/models/set_tmp.js +203 -0
  22. package/lib/cjs/models/solar_gain.js +163 -0
  23. package/lib/cjs/models/two_nodes.js +790 -0
  24. package/lib/cjs/models/use_fans_heatwave.js +203 -0
  25. package/lib/cjs/models/utci.js +609 -0
  26. package/lib/cjs/models/vertical_tmp_grad_ppd.js +95 -0
  27. package/lib/cjs/models/wbgt.js +72 -0
  28. package/lib/cjs/models/wc.js +37 -0
  29. package/lib/cjs/psychrometrics/enthalpy.js +24 -0
  30. package/lib/cjs/psychrometrics/index.js +28 -0
  31. package/lib/cjs/psychrometrics/p_sat.js +46 -0
  32. package/lib/cjs/psychrometrics/p_sat_torr.js +34 -0
  33. package/lib/cjs/psychrometrics/psy_ta_rh.js +51 -0
  34. package/lib/cjs/psychrometrics/t_dp.js +19 -0
  35. package/lib/cjs/psychrometrics/t_mrt.js +117 -0
  36. package/lib/cjs/psychrometrics/t_o.js +82 -0
  37. package/lib/cjs/psychrometrics/t_wb.js +23 -0
  38. package/lib/cjs/types/index.d.ts +7 -79
  39. package/lib/cjs/types/index.d.ts.map +1 -1
  40. package/lib/cjs/types/models/a_pmv.d.ts +133 -0
  41. package/lib/cjs/types/models/a_pmv.d.ts.map +1 -0
  42. package/lib/cjs/types/models/adaptive_ashrae.d.ts +211 -0
  43. package/lib/cjs/types/models/adaptive_ashrae.d.ts.map +1 -0
  44. package/lib/cjs/types/models/adaptive_en.d.ts +217 -0
  45. package/lib/cjs/types/models/adaptive_en.d.ts.map +1 -0
  46. package/lib/cjs/types/models/ankle_draft.d.ts +60 -0
  47. package/lib/cjs/types/models/ankle_draft.d.ts.map +1 -0
  48. package/lib/cjs/types/models/at.d.ts +34 -0
  49. package/lib/cjs/types/models/at.d.ts.map +1 -0
  50. package/lib/cjs/types/models/athb.d.ts +96 -0
  51. package/lib/cjs/types/models/athb.d.ts.map +1 -0
  52. package/lib/cjs/types/models/clo_tout.d.ts +45 -0
  53. package/lib/cjs/types/models/clo_tout.d.ts.map +1 -0
  54. package/lib/cjs/types/models/cooling_effect.d.ts +49 -0
  55. package/lib/cjs/types/models/cooling_effect.d.ts.map +1 -0
  56. package/lib/cjs/types/models/discomfort_index.d.ts +91 -0
  57. package/lib/cjs/types/models/discomfort_index.d.ts.map +1 -0
  58. package/lib/cjs/types/models/e_pmv.d.ts +139 -0
  59. package/lib/cjs/types/models/e_pmv.d.ts.map +1 -0
  60. package/lib/cjs/types/models/heat_index.d.ts +27 -0
  61. package/lib/cjs/types/models/heat_index.d.ts.map +1 -0
  62. package/lib/cjs/types/models/humidex.d.ts +54 -0
  63. package/lib/cjs/types/models/humidex.d.ts.map +1 -0
  64. package/lib/cjs/types/models/index.d.ts +78 -0
  65. package/lib/cjs/types/models/index.d.ts.map +1 -0
  66. package/lib/cjs/types/models/net.d.ts +39 -0
  67. package/lib/cjs/types/models/net.d.ts.map +1 -0
  68. package/lib/cjs/types/models/pet_steady.d.ts +59 -0
  69. package/lib/cjs/types/models/pet_steady.d.ts.map +1 -0
  70. package/lib/cjs/types/models/phs.d.ts +242 -0
  71. package/lib/cjs/types/models/phs.d.ts.map +1 -0
  72. package/lib/cjs/types/models/pmv.d.ts +198 -0
  73. package/lib/cjs/types/models/pmv.d.ts.map +1 -0
  74. package/lib/cjs/types/models/pmv_ppd.d.ts +246 -0
  75. package/lib/cjs/types/models/pmv_ppd.d.ts.map +1 -0
  76. package/lib/cjs/types/models/set_tmp.d.ts +124 -0
  77. package/lib/cjs/types/models/set_tmp.d.ts.map +1 -0
  78. package/lib/cjs/types/models/solar_gain.d.ts +76 -0
  79. package/lib/cjs/types/models/solar_gain.d.ts.map +1 -0
  80. package/lib/cjs/types/models/two_nodes.d.ts +412 -0
  81. package/lib/cjs/types/models/two_nodes.d.ts.map +1 -0
  82. package/lib/cjs/types/models/use_fans_heatwave.d.ts +188 -0
  83. package/lib/cjs/types/models/use_fans_heatwave.d.ts.map +1 -0
  84. package/lib/cjs/types/models/utci.d.ts +79 -0
  85. package/lib/cjs/types/models/utci.d.ts.map +1 -0
  86. package/lib/cjs/types/models/vertical_tmp_grad_ppd.d.ts +58 -0
  87. package/lib/cjs/types/models/vertical_tmp_grad_ppd.d.ts.map +1 -0
  88. package/lib/cjs/types/models/wbgt.d.ts +51 -0
  89. package/lib/cjs/types/models/wbgt.d.ts.map +1 -0
  90. package/lib/cjs/types/models/wc.d.ts +29 -0
  91. package/lib/cjs/types/models/wc.d.ts.map +1 -0
  92. package/lib/cjs/types/psychrometrics/enthalpy.d.ts +12 -0
  93. package/lib/cjs/types/psychrometrics/enthalpy.d.ts.map +1 -0
  94. package/lib/cjs/types/psychrometrics/index.d.ts +26 -0
  95. package/lib/cjs/types/psychrometrics/index.d.ts.map +1 -0
  96. package/lib/cjs/types/psychrometrics/p_sat.d.ts +13 -0
  97. package/lib/cjs/types/psychrometrics/p_sat.d.ts.map +1 -0
  98. package/lib/cjs/types/psychrometrics/p_sat_torr.d.ts +26 -0
  99. package/lib/cjs/types/psychrometrics/p_sat_torr.d.ts.map +1 -0
  100. package/lib/cjs/types/psychrometrics/psy_ta_rh.d.ts +51 -0
  101. package/lib/cjs/types/psychrometrics/psy_ta_rh.d.ts.map +1 -0
  102. package/lib/cjs/types/psychrometrics/t_dp.d.ts +9 -0
  103. package/lib/cjs/types/psychrometrics/t_dp.d.ts.map +1 -0
  104. package/lib/cjs/types/psychrometrics/t_mrt.d.ts +43 -0
  105. package/lib/cjs/types/psychrometrics/t_mrt.d.ts.map +1 -0
  106. package/lib/cjs/types/psychrometrics/t_o.d.ts +31 -0
  107. package/lib/cjs/types/psychrometrics/t_o.d.ts.map +1 -0
  108. package/lib/cjs/types/psychrometrics/t_wb.d.ts +12 -0
  109. package/lib/cjs/types/psychrometrics/t_wb.d.ts.map +1 -0
  110. package/lib/cjs/types/utilities/index.d.ts +28 -0
  111. package/lib/cjs/types/utilities/index.d.ts.map +1 -0
  112. package/lib/cjs/types/utilities/utilities.d.ts +377 -0
  113. package/lib/cjs/types/utilities/utilities.d.ts.map +1 -0
  114. package/lib/cjs/utilities/index.js +27 -0
  115. package/lib/cjs/utilities/utilities.js +903 -0
  116. package/lib/esm/index.js +4 -0
  117. package/lib/esm/models/a_pmv.js +135 -0
  118. package/lib/esm/models/adaptive_ashrae.js +285 -0
  119. package/lib/esm/models/adaptive_en.js +294 -0
  120. package/lib/esm/models/ankle_draft.js +78 -0
  121. package/lib/esm/models/at.js +48 -0
  122. package/lib/esm/models/athb.js +130 -0
  123. package/lib/esm/models/clo_tout.js +53 -0
  124. package/lib/esm/models/cooling_effect.js +159 -0
  125. package/lib/esm/models/discomfort_index.js +110 -0
  126. package/lib/esm/models/e_pmv.js +149 -0
  127. package/lib/esm/models/heat_index.js +56 -0
  128. package/lib/esm/models/humidex.js +59 -0
  129. package/lib/esm/models/index.js +69 -0
  130. package/lib/esm/models/net.js +46 -0
  131. package/lib/esm/models/pet_steady.js +439 -0
  132. package/lib/esm/models/phs.js +454 -0
  133. package/lib/esm/models/pmv.js +195 -0
  134. package/lib/esm/models/pmv_ppd.js +398 -0
  135. package/lib/esm/models/set_tmp.js +198 -0
  136. package/lib/esm/models/solar_gain.js +158 -0
  137. package/lib/esm/models/two_nodes.js +784 -0
  138. package/lib/esm/models/use_fans_heatwave.js +199 -0
  139. package/lib/esm/models/utci.js +604 -0
  140. package/lib/esm/models/wbgt.js +68 -0
  141. package/lib/esm/models/wc.js +33 -0
  142. package/lib/esm/psychrometrics/enthalpy.js +20 -0
  143. package/lib/esm/psychrometrics/index.js +26 -0
  144. package/lib/esm/psychrometrics/p_sat.js +42 -0
  145. package/lib/esm/psychrometrics/p_sat_torr.js +29 -0
  146. package/lib/esm/psychrometrics/psy_ta_rh.js +47 -0
  147. package/lib/esm/psychrometrics/t_dp.js +15 -0
  148. package/lib/esm/psychrometrics/t_mrt.js +112 -0
  149. package/lib/esm/psychrometrics/t_o.js +77 -0
  150. package/lib/esm/psychrometrics/t_wb.js +19 -0
  151. package/lib/esm/types/index.d.ts +7 -79
  152. package/lib/esm/types/index.d.ts.map +1 -1
  153. package/lib/esm/types/models/a_pmv.d.ts +133 -0
  154. package/lib/esm/types/models/a_pmv.d.ts.map +1 -0
  155. package/lib/esm/types/models/adaptive_ashrae.d.ts +211 -0
  156. package/lib/esm/types/models/adaptive_ashrae.d.ts.map +1 -0
  157. package/lib/esm/types/models/adaptive_en.d.ts +217 -0
  158. package/lib/esm/types/models/adaptive_en.d.ts.map +1 -0
  159. package/lib/esm/types/models/ankle_draft.d.ts +60 -0
  160. package/lib/esm/types/models/ankle_draft.d.ts.map +1 -0
  161. package/lib/esm/types/models/at.d.ts +34 -0
  162. package/lib/esm/types/models/at.d.ts.map +1 -0
  163. package/lib/esm/types/models/athb.d.ts +96 -0
  164. package/lib/esm/types/models/athb.d.ts.map +1 -0
  165. package/lib/esm/types/models/clo_tout.d.ts +45 -0
  166. package/lib/esm/types/models/clo_tout.d.ts.map +1 -0
  167. package/lib/esm/types/models/cooling_effect.d.ts +49 -0
  168. package/lib/esm/types/models/cooling_effect.d.ts.map +1 -0
  169. package/lib/esm/types/models/discomfort_index.d.ts +91 -0
  170. package/lib/esm/types/models/discomfort_index.d.ts.map +1 -0
  171. package/lib/esm/types/models/e_pmv.d.ts +139 -0
  172. package/lib/esm/types/models/e_pmv.d.ts.map +1 -0
  173. package/lib/esm/types/models/heat_index.d.ts +27 -0
  174. package/lib/esm/types/models/heat_index.d.ts.map +1 -0
  175. package/lib/esm/types/models/humidex.d.ts +54 -0
  176. package/lib/esm/types/models/humidex.d.ts.map +1 -0
  177. package/lib/esm/types/models/index.d.ts +77 -0
  178. package/lib/esm/types/models/index.d.ts.map +1 -0
  179. package/lib/esm/types/models/net.d.ts +39 -0
  180. package/lib/esm/types/models/net.d.ts.map +1 -0
  181. package/lib/esm/types/models/pet_steady.d.ts +59 -0
  182. package/lib/esm/types/models/pet_steady.d.ts.map +1 -0
  183. package/lib/esm/types/models/phs.d.ts +242 -0
  184. package/lib/esm/types/models/phs.d.ts.map +1 -0
  185. package/lib/esm/types/models/pmv.d.ts +198 -0
  186. package/lib/esm/types/models/pmv.d.ts.map +1 -0
  187. package/lib/esm/types/models/pmv_ppd.d.ts +246 -0
  188. package/lib/esm/types/models/pmv_ppd.d.ts.map +1 -0
  189. package/lib/esm/types/models/set_tmp.d.ts +124 -0
  190. package/lib/esm/types/models/set_tmp.d.ts.map +1 -0
  191. package/lib/esm/types/models/solar_gain.d.ts +76 -0
  192. package/lib/esm/types/models/solar_gain.d.ts.map +1 -0
  193. package/lib/esm/types/models/two_nodes.d.ts +412 -0
  194. package/lib/esm/types/models/two_nodes.d.ts.map +1 -0
  195. package/lib/esm/types/models/use_fans_heatwave.d.ts +188 -0
  196. package/lib/esm/types/models/use_fans_heatwave.d.ts.map +1 -0
  197. package/lib/esm/types/models/utci.d.ts +79 -0
  198. package/lib/esm/types/models/utci.d.ts.map +1 -0
  199. package/lib/esm/types/models/wbgt.d.ts +51 -0
  200. package/lib/esm/types/models/wbgt.d.ts.map +1 -0
  201. package/lib/esm/types/models/wc.d.ts +29 -0
  202. package/lib/esm/types/models/wc.d.ts.map +1 -0
  203. package/lib/esm/types/psychrometrics/enthalpy.d.ts +12 -0
  204. package/lib/esm/types/psychrometrics/enthalpy.d.ts.map +1 -0
  205. package/lib/esm/types/psychrometrics/index.d.ts +26 -0
  206. package/lib/esm/types/psychrometrics/index.d.ts.map +1 -0
  207. package/lib/esm/types/psychrometrics/p_sat.d.ts +13 -0
  208. package/lib/esm/types/psychrometrics/p_sat.d.ts.map +1 -0
  209. package/lib/esm/types/psychrometrics/p_sat_torr.d.ts +26 -0
  210. package/lib/esm/types/psychrometrics/p_sat_torr.d.ts.map +1 -0
  211. package/lib/esm/types/psychrometrics/psy_ta_rh.d.ts +51 -0
  212. package/lib/esm/types/psychrometrics/psy_ta_rh.d.ts.map +1 -0
  213. package/lib/esm/types/psychrometrics/t_dp.d.ts +9 -0
  214. package/lib/esm/types/psychrometrics/t_dp.d.ts.map +1 -0
  215. package/lib/esm/types/psychrometrics/t_mrt.d.ts +43 -0
  216. package/lib/esm/types/psychrometrics/t_mrt.d.ts.map +1 -0
  217. package/lib/esm/types/psychrometrics/t_o.d.ts +31 -0
  218. package/lib/esm/types/psychrometrics/t_o.d.ts.map +1 -0
  219. package/lib/esm/types/psychrometrics/t_wb.d.ts +12 -0
  220. package/lib/esm/types/psychrometrics/t_wb.d.ts.map +1 -0
  221. package/lib/esm/types/utilities/index.d.ts +28 -0
  222. package/lib/esm/types/utilities/index.d.ts.map +1 -0
  223. package/lib/esm/types/utilities/utilities.d.ts +377 -0
  224. package/lib/esm/types/utilities/utilities.d.ts.map +1 -0
  225. package/lib/esm/utilities/index.js +25 -0
  226. package/lib/esm/utilities/utilities.js +885 -0
  227. package/package.json +22 -15
  228. package/lib/esm/index.mjs +0 -430
@@ -0,0 +1,404 @@
1
+ "use strict";
2
+ Object.defineProperty(exports, "__esModule", { value: true });
3
+ exports.pmv_calculation = exports.pmv_ppd_array = exports.pmv_ppd = void 0;
4
+ const utilities_js_1 = require("../utilities/utilities.js");
5
+ const cooling_effect_js_1 = require("./cooling_effect.js");
6
+ /**
7
+ * @typedef {Object} Pmv_ppdKwargs
8
+ * @property {'SI'|'IP'} units - select the SI (International System of Units) or the IP (Imperial Units) system.
9
+ * @property { boolean } limit_inputs - Default is True. By default, if the inputs are outside the standard applicability
10
+ * limits the function returns NaN. If false, returns pmv and ppd values even if input values are outside
11
+ * the applicability limits of the model.
12
+ *
13
+ * The ASHRAE 55 2020 limits are 10 < tdb [°C] < 40, 10 < tr [°C] < 40,
14
+ * 0 < vr [m/s] < 2, 1 < met [met] < 4, and 0 < clo [clo] < 1.5.
15
+ * The ISO 7730 2005 limits are 10 < tdb [°C] < 30, 10 < tr [°C] < 40,
16
+ * 0 < vr [m/s] < 1, 0.8 < met [met] < 4, 0 < clo [clo] < 2, and -2 < PMV < 2.
17
+ * @property { boolean } airspeed_control - This only applies if standard = "ASHRAE".
18
+ *
19
+ * Default is True. By default, it is assumed that the occupant has control over the airspeed.
20
+ * In this case, the ASHRAE 55 Standard does not impose any airspeed limits.
21
+ * On the other hand, if the occupant has no control over the airspeed,
22
+ * the ASHRAE 55 imposes an upper limit for v which varies as a function of
23
+ * the operative temperature, for more information please consult the Standard.
24
+ * @public
25
+ */
26
+ /**
27
+ * @typedef {Object} Pmv_ppdReturns
28
+ * @property { number } pmv - Predicted Mean Vote
29
+ * @property { number } ppd - Predicted Percentage of Dissatisfied occupants, [%]
30
+ * @public
31
+ */
32
+ /**
33
+ * Returns Predicted Mean Vote ( {@link https://en.wikipedia.org/wiki/Thermal_comfort#PMV/PPD_method|PMV} ) and
34
+ * Predicted Percentage of Dissatisfied ( {@link https://en.wikipedia.org/wiki/Thermal_comfort#PMV/PPD_method|PPD} )
35
+ * calculated in accordance with main thermal comfort Standards. The PMV is an index that predicts the mean
36
+ * value of the thermal sensation votes (self-reported perceptions) of a large group of people on a
37
+ * sensation scale expressed from –3 to +3 corresponding to the categories:
38
+ * cold, cool, slightly cool, neutral, slightly warm, warm, and hot. {@link #ref_1|[1]}
39
+ *
40
+ * While the PMV equation is the same for both the ISO and ASHRAE standards, in the
41
+ * ASHRAE 55 PMV equation, the SET is used to calculate the cooling effect first,
42
+ * this is then subtracted from both the air and mean radiant temperatures, and the
43
+ * differences are used as input to the PMV model, while the airspeed is set to 0.1m/s.
44
+ * Please read more in the Note below.
45
+ *
46
+ * Notes:
47
+ *
48
+ * You can use this function to calculate the {@link https://en.wikipedia.org/wiki/Thermal_comfort#PMV/PPD_method|PMV}
49
+ * and {@link https://en.wikipedia.org/wiki/Thermal_comfort#PMV/PPD_method|PPD} in accordance with
50
+ * either the ASHRAE 55 2020 Standard {@link #ref_1|[1]} or the ISO 7730 Standard {@link #ref_2|[2]}.
51
+ *
52
+ * This is a version that supports scalar arguments.
53
+ * @see {@link pmv_ppd_array} for a version that supports arrays.
54
+ *
55
+ * @public
56
+ * @memberof models
57
+ * @docname Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD)
58
+ *
59
+ * @param { number } tdb - dry bulb air temperature, default in [°C] in [°F] if `units` = 'IP'
60
+ * @param { number } tr - mean radiant temperature, default in [°C] in [°F] if `units` = 'IP'
61
+ * @param { number } vr - relative air speed, default in [m/s] in [fps] if `units` = 'IP'
62
+ *
63
+ * Note: vr is the relative air speed caused by body movement and not the air
64
+ * speed measured by the air speed sensor. The relative air speed is the sum of the
65
+ * average air speed measured by the sensor plus the activity-generated air speed
66
+ * (Vag). Where Vag is the activity-generated air speed caused by motion of
67
+ * individual body parts. vr can be calculated using the function `v_relative` which is in .utilities.js.
68
+ * @param { number } rh - relative humidity, [%]
69
+ * @param { number } met - metabolic rate
70
+ * @param { number } clo - clothing insulation
71
+ *
72
+ * Note: The activity as well as the air speed modify the insulation characteristics
73
+ * of the clothing and the adjacent air layer. Consequently, the ISO 7730 states that
74
+ * the clothing insulation shall be corrected {@link #ref_2|[2]}. The ASHRAE 55 Standard corrects
75
+ * for the effect of the body movement for met equal or higher than 1.2 met using
76
+ * the equation clo = Icl × (0.6 + 0.4/met) The dynamic clothing insulation, clo,
77
+ * can be calculated using the function `clo_dynamic` which is in .utilities.js.
78
+ * @param { number } [wme=0] - external work
79
+ * @param { "ISO"|"ASHRAE" } [standard="ISO"] - comfort standard used for calculation
80
+ *
81
+ * · If "ISO", then the ISO Equation is used
82
+ *
83
+ * · If "ASHRAE", then the ASHRAE Equation is used
84
+ *
85
+ * Note: While the PMV equation is the same for both the ISO and ASHRAE standards, the ASHRAE Standard Use of
86
+ * the PMV model is limited to air speeds below 0.10m/s (20 fpm). When air speeds exceed 0.10 m/s (20 fpm), the comfort
87
+ * zone boundaries are adjusted based on the SET model. This change was introduced by the
88
+ * {@link https://www.ashrae.org/file%20library/technical%20resources/standards%20and%20guidelines/standards%20addenda/55_2020_c_20210430.pdf|Addendum_C to Standard 55-2020}
89
+ * @param { Pmv_ppdKwargs }kwargs - additional arguments
90
+ *
91
+ * @returns { Pmv_ppdReturns } - Result of pmv and ppd
92
+ *
93
+ * @example
94
+ * const tdb = 25;
95
+ * const tr = 25;
96
+ * const rh = 50;
97
+ * const v = 0.1;
98
+ * const met = 1.4;
99
+ * const clo = 0.5;
100
+ * // Calculate relative air speed
101
+ * const v_r = v_relative(v, met);
102
+ * // Calculate dynamic clothing
103
+ * const clo_d = clo_dynamic(clo, met);
104
+ * const results = pmv_ppd(tdb, tr, v_r, rh, met, clo_d);
105
+ * console.log(results); // Output: { pmv: 0.06, ppd: 5.1 }
106
+ * console.log(results.pmv); // Output: -0.06
107
+ */
108
+ function pmv_ppd(tdb, tr, vr, rh, met, clo, wme = 0, standard = "ISO", kwargs = {}) {
109
+ const default_kwargs = {
110
+ units: "SI",
111
+ limit_inputs: true,
112
+ airspeed_control: true,
113
+ };
114
+ kwargs = Object.assign(default_kwargs, kwargs);
115
+ if (kwargs.units && kwargs.units === "IP") {
116
+ // Conversion from IP to SI units
117
+ ({ tdb, tr, vr } = (0, utilities_js_1.units_converter)({ tdb, tr, vr }, "IP"));
118
+ }
119
+ if (standard !== "ISO" && standard !== "ASHRAE") {
120
+ throw new Error("PMV calculations can only be performed in compliance with ISO or ASHRAE Standards");
121
+ }
122
+ const { tdb: tdb_valid, tr: tr_valid, v: v_valid, met: met_valid, clo: clo_valid, } = (0, utilities_js_1.check_standard_compliance_array)(standard, {
123
+ tdb: [tdb],
124
+ tr: [tr],
125
+ v: [vr],
126
+ met: [met],
127
+ clo: [clo],
128
+ airspeed_control: kwargs.airspeed_control,
129
+ });
130
+ let ce = 0;
131
+ if (standard === "ASHRAE") {
132
+ //if v_r is higher than 0.1 follow methodology ASHRAE Appendix H, H3
133
+ ce = vr > 0.1 ? (0, cooling_effect_js_1.cooling_effect)(tdb, tr, vr, rh, met, clo, wme) : 0;
134
+ }
135
+ tdb = tdb - ce;
136
+ tr = tr - ce;
137
+ vr = ce > 0 ? 0.1 : vr;
138
+ let pmv = pmv_calculation(tdb, tr, vr, rh, met, clo, wme);
139
+ let ppd = 100.0 -
140
+ 95.0 *
141
+ Math.exp(-0.03353 * Math.pow(pmv, 4.0) - 0.2179 * Math.pow(pmv, 2.0));
142
+ // Checks that inputs are within the bounds accepted by the model if not return NaN
143
+ if (kwargs.limit_inputs) {
144
+ const pmv_valid = standard === "ASHRAE"
145
+ ? (0, utilities_js_1.valid_range)([pmv], [-100, 100])
146
+ : (0, utilities_js_1.valid_range)([pmv], [-2, 2]); // this is the ISO limit
147
+ if (isNaN(pmv) ||
148
+ tdb_valid.includes(NaN) ||
149
+ tr_valid.includes(NaN) ||
150
+ v_valid.includes(NaN) ||
151
+ met_valid.includes(NaN) ||
152
+ clo_valid.includes(NaN) ||
153
+ pmv_valid.includes(NaN)) {
154
+ pmv = NaN;
155
+ ppd = NaN;
156
+ }
157
+ }
158
+ return {
159
+ pmv: (0, utilities_js_1.round)(pmv, 2),
160
+ ppd: (0, utilities_js_1.round)(ppd, 1),
161
+ };
162
+ }
163
+ exports.pmv_ppd = pmv_ppd;
164
+ /**
165
+ * @typedef {Object} Pmv_ppd_arrayReturns
166
+ * @property { number[] } pmv - Predicted Mean Vote
167
+ * @property { number[] } ppd - Predicted Percentage of Dissatisfied occupants, [%]
168
+ * @public
169
+ */
170
+ /**
171
+ * Returns Predicted Mean Vote ( {@link https://en.wikipedia.org/wiki/Thermal_comfort#PMV/PPD_method|PMV} ) and
172
+ * Predicted Percentage of Dissatisfied ( {@link https://en.wikipedia.org/wiki/Thermal_comfort#PMV/PPD_method|PPD} )
173
+ * calculated in accordance with main thermal comfort Standards. The PMV is an index that predicts the mean
174
+ * value of the thermal sensation votes (self-reported perceptions) of a large group of people on a
175
+ * sensation scale expressed from –3 to +3 corresponding to the categories:
176
+ * cold, cool, slightly cool, neutral, slightly warm, warm, and hot. {@link #ref_1|[1]}
177
+ *
178
+ * While the PMV equation is the same for both the ISO and ASHRAE standards, in the
179
+ * ASHRAE 55 PMV equation, the SET is used to calculate the cooling effect first,
180
+ * this is then subtracted from both the air and mean radiant temperatures, and the
181
+ * differences are used as input to the PMV model, while the airspeed is set to 0.1m/s.
182
+ * Please read more in the Note below.
183
+ *
184
+ * Notes:
185
+ *
186
+ * You can use this function to calculate the {@link https://en.wikipedia.org/wiki/Thermal_comfort#PMV/PPD_method|PMV}
187
+ * and {@link https://en.wikipedia.org/wiki/Thermal_comfort#PMV/PPD_method|PPD} in accordance with
188
+ * either the ASHRAE 55 2020 Standard {@link #ref_1|[1]} or the ISO 7730 Standard {@link #ref_2|[2]}.
189
+ *
190
+ * This is a version that supports arrays.
191
+ * @see {@link pmv_ppd} for a version that supports scalar arguments.
192
+ *
193
+ * @public
194
+ * @memberof models
195
+ * @docname Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD) (array version)
196
+ *
197
+ * @param { number[] } tdb - dry bulb air temperature, default in [°C] in [°F] if `units` = 'IP'
198
+ * @param { number[] } tr - mean radiant temperature, default in [°C] in [°F] if `units` = 'IP'
199
+ * @param { number[] } vr - relative air speed, default in [m/s] in [fps] if `units` = 'IP'
200
+ *
201
+ * Note: vr is the relative air speed caused by body movement and not the air
202
+ * speed measured by the air speed sensor. The relative air speed is the sum of the
203
+ * average air speed measured by the sensor plus the activity-generated air speed
204
+ * (Vag). Where Vag is the activity-generated air speed caused by motion of
205
+ * individual body parts. vr can be calculated using the function `v_relative_array` which is in .utilities.js.
206
+ * @param { number[] } rh - relative humidity, [%]
207
+ * @param { number[] } met - metabolic rate, [met]
208
+ * @param { number[] } clo - clothing insulation, [clo]
209
+ *
210
+ * Note: The activity as well as the air speed modify the insulation characteristics
211
+ * of the clothing and the adjacent air layer. Consequently, the ISO 7730 states that
212
+ * the clothing insulation shall be corrected {@link #ref_2|[2]}. The ASHRAE 55 Standard corrects
213
+ * for the effect of the body movement for met equal or higher than 1.2 met using
214
+ * the equation clo = Icl × (0.6 + 0.4/met) The dynamic clothing insulation, clo,
215
+ * can be calculated using the function `clo_dynamic_array` which is in .utilities.js.
216
+ * @param { number[] } wme - external work, default is array of 0
217
+ * @param { "ISO"|"ASHRAE" } [standard="ISO"] - comfort standard used for calculation
218
+ *
219
+ * · If "ISO", then the ISO Equation is used
220
+ *
221
+ * · If "ASHRAE", then the ASHRAE Equation is used
222
+ *
223
+ * Note: While the PMV equation is the same for both the ISO and ASHRAE standards, the ASHRAE Standard Use of
224
+ * the PMV model is limited to air speeds below 0.10m/s (20 fpm). When air speeds exceed 0.10 m/s (20 fpm), the comfort
225
+ * zone boundaries are adjusted based on the SET model. This change was introduced by the
226
+ * {@link https://www.ashrae.org/file%20library/technical%20resources/standards%20and%20guidelines/standards%20addenda/55_2020_c_20210430.pdf|Addendum_C to Standard 55-2020}
227
+ * @param { Pmv_ppdKwargs }kwargs - additional arguments
228
+ *
229
+ * @returns {Pmv_ppd_arrayReturns} - Result of pmv and ppd
230
+ *
231
+ * @example
232
+ * const tdb = [22, 25];
233
+ * const tr = [25, 25];
234
+ * const rh = [50, 50];
235
+ * const v = [0.1, 0.1];
236
+ * const met = [1.4, 1.4];
237
+ * const clo = [0.5, 0.5];
238
+ * // Calculate relative air speed
239
+ * const v_r = v_relative_array(v, met);
240
+ * // Calculate dynamic clothing
241
+ * const clo_d = clo_dynamic_array(clo, met);
242
+ * const arrayResults = pmv_ppd_array(tdb, tr, v_r, rh, met, clo_d);
243
+ * console.log(arrayResults); // Output: { pmv: [-0.47, 0.06], ppd: [9.6, 5.1] }
244
+ * console.log(results.pmv); // Output: [-0.47, 0.06]
245
+ */
246
+ function pmv_ppd_array(tdb, tr, vr, rh, met, clo, wme, standard = "ISO", kwargs = {}) {
247
+ const default_kwargs = {
248
+ units: "SI",
249
+ limit_inputs: true,
250
+ airspeed_control: true,
251
+ };
252
+ kwargs = Object.assign(default_kwargs, kwargs);
253
+ // default wme is an array of 0
254
+ if (wme === undefined) {
255
+ wme = tdb.map(() => 0);
256
+ }
257
+ if (kwargs.units && kwargs.units === "IP") {
258
+ // Conversion from IP to SI units
259
+ ({ tdb, tr, vr } = (0, utilities_js_1.units_converter_array)({ tdb, tr, vr }, "IP"));
260
+ }
261
+ if (standard !== "ISO" && standard !== "ASHRAE") {
262
+ throw new Error("PMV calculations can only be performed in compliance with ISO or ASHRAE Standards");
263
+ }
264
+ const { tdb: tdb_valid, tr: tr_valid, v: v_valid, met: met_valid, clo: clo_valid, } = (0, utilities_js_1.check_standard_compliance_array)(standard, {
265
+ tdb,
266
+ tr,
267
+ v: vr,
268
+ met,
269
+ clo,
270
+ airspeed_control: kwargs.airspeed_control,
271
+ });
272
+ let ce = [];
273
+ if (standard === "ASHRAE") {
274
+ ce = vr.map((vrValue, i) => {
275
+ //if v_r is higher than 0.1 follow methodology ASHRAE Appendix H, H3
276
+ return vrValue > 0.1
277
+ ? (0, cooling_effect_js_1.cooling_effect)(tdb[i], tr[i], vrValue, rh[i], met[i], clo[i], wme[i])
278
+ : 0;
279
+ });
280
+ }
281
+ if (ce.length === 0) {
282
+ for (let i = 0; i < tdb.length; i++) {
283
+ ce[i] = 0;
284
+ }
285
+ }
286
+ for (let i = 0; i < tdb.length; i++) {
287
+ tdb[i] -= ce[i];
288
+ tr[i] -= ce[i];
289
+ if (ce[i] > 0) {
290
+ vr[i] = 0.1;
291
+ }
292
+ }
293
+ const pmv_array = tdb.map((tdbValue, i) => pmv_calculation(tdbValue, tr[i], vr[i], rh[i], met[i], clo[i], wme[i]));
294
+ const ppd_array = pmv_array.map((pmvValue) => {
295
+ return (100 -
296
+ 95 *
297
+ Math.exp(-0.03353 * Math.pow(pmvValue, 4) - 0.2179 * Math.pow(pmvValue, 2)));
298
+ });
299
+ // Checks that inputs are within the bounds accepted by the model if not return NaN
300
+ if (kwargs.limit_inputs) {
301
+ const pmv_valid = standard === "ASHRAE"
302
+ ? (0, utilities_js_1.valid_range)(pmv_array, [-100, 100])
303
+ : (0, utilities_js_1.valid_range)(pmv_array, [-2, 2]); // this is the ISO limit
304
+ for (let i = 0; i < pmv_array.length; ++i) {
305
+ if (isNaN(pmv_array[i]) ||
306
+ isNaN(tdb_valid[i]) ||
307
+ isNaN(tr_valid[i]) ||
308
+ isNaN(v_valid[i]) ||
309
+ isNaN(met_valid[i]) ||
310
+ isNaN(clo_valid[i]) ||
311
+ isNaN(pmv_valid[i])) {
312
+ pmv_array[i] = NaN;
313
+ ppd_array[i] = NaN;
314
+ }
315
+ }
316
+ }
317
+ for (let i = 0; i < pmv_array.length; ++i) {
318
+ pmv_array[i] = (0, utilities_js_1.round)(pmv_array[i], 2);
319
+ ppd_array[i] = (0, utilities_js_1.round)(ppd_array[i], 1);
320
+ }
321
+ return {
322
+ pmv: pmv_array,
323
+ ppd: ppd_array,
324
+ };
325
+ }
326
+ exports.pmv_ppd_array = pmv_ppd_array;
327
+ /**
328
+ * @param {number} tdb
329
+ * @param {number} tr
330
+ * @param {number} vr
331
+ * @param {number} rh
332
+ * @param {number} met
333
+ * @param {number} clo
334
+ * @param {number} wme
335
+ *
336
+ * @returns {number} _pmv
337
+ */
338
+ function pmv_calculation(tdb, tr, vr, rh, met, clo, wme) {
339
+ const pa = rh * 10 * Math.exp(16.6536 - 4030.183 / (tdb + 235));
340
+ const icl = 0.155 * clo; //thermal insulation of the clothing in M2K/W
341
+ const m = met * 58.15; //metabolic rate in W/M2
342
+ const w = wme * 58.15; //external work in W/M2
343
+ const mw = m - w; //internal heat production in the human body
344
+ //calculation of the clothing area factor
345
+ let f_cl;
346
+ if (icl <= 0.078) {
347
+ f_cl = 1 + 1.29 * icl; // ratio of surface clothed body over nude body
348
+ }
349
+ else {
350
+ f_cl = 1.05 + 0.645 * icl;
351
+ }
352
+ //heat transfer coefficient by forced convection
353
+ const hcf = 12.1 * Math.sqrt(vr);
354
+ let hc = hcf;
355
+ const taa = tdb + 273;
356
+ const tra = tr + 273;
357
+ const t_cla = taa + (35.5 - tdb) / (3.5 * icl + 0.1);
358
+ const p1 = icl * f_cl;
359
+ const p2 = p1 * 3.96;
360
+ const p3 = p1 * 100;
361
+ const p4 = p1 * taa;
362
+ const p5 = 308.7 - 0.028 * mw + p2 * Math.pow(tra / 100.0, 4);
363
+ let xn = t_cla / 100;
364
+ let xf = t_cla / 50;
365
+ const eps = 0.00015;
366
+ let n = 0;
367
+ while (Math.abs(xn - xf) > eps) {
368
+ xf = (xf + xn) / 2;
369
+ let hcn = 2.38 * Math.pow(Math.abs(100.0 * xf - taa), 0.25);
370
+ if (hcf > hcn) {
371
+ hc = hcf;
372
+ }
373
+ else {
374
+ hc = hcn;
375
+ }
376
+ xn = (p5 + p4 * hc - p2 * Math.pow(xf, 4)) / (100 + p3 * hc);
377
+ n += 1;
378
+ if (n > 150) {
379
+ throw new Error("Max iterations exceeded");
380
+ }
381
+ }
382
+ const tcl = 100 * xn - 273;
383
+ //heat loss diff. through skin
384
+ const hl1 = 3.05 * 0.001 * (5733 - 6.99 * mw - pa);
385
+ //heat loss by sweating
386
+ let hl2;
387
+ if (mw > 58.15) {
388
+ hl2 = 0.42 * (mw - 58.15);
389
+ }
390
+ else {
391
+ hl2 = 0;
392
+ }
393
+ //latent respiration heat loss
394
+ const hl3 = 1.7 * 0.00001 * m * (5867 - pa);
395
+ //dry respiration heat loss
396
+ const hl4 = 0.0014 * m * (34 - tdb);
397
+ //heat loss by radiation
398
+ const hl5 = 3.96 * f_cl * (Math.pow(xn, 4) - Math.pow(tra / 100.0, 4));
399
+ //heat loss by convection
400
+ const hl6 = f_cl * hc * (tcl - tdb);
401
+ const ts = 0.303 * Math.exp(-0.036 * m) + 0.028;
402
+ return ts * (mw - hl1 - hl2 - hl3 - hl4 - hl5 - hl6);
403
+ }
404
+ exports.pmv_calculation = pmv_calculation;
@@ -0,0 +1,203 @@
1
+ "use strict";
2
+ Object.defineProperty(exports, "__esModule", { value: true });
3
+ exports.set_tmp_array = exports.set_tmp = void 0;
4
+ const utilities_js_1 = require("../utilities/utilities.js");
5
+ const two_nodes_js_1 = require("../models/two_nodes.js");
6
+ /**
7
+ * @typedef {Object} SetTmpKwargs - a keywords argument set containing the additional arguments for Standard Effective Temperature calculation
8
+ * @property {boolean} [round=true] - round the result of the SET
9
+ * @property {boolean} [calculate_ce=false] - select if SET is used to calculate Cooling Effect
10
+ * @public
11
+ */
12
+ /**
13
+ * @typedef {Object} SetTmpKwargsRequired
14
+ * @property {boolean} round
15
+ * @property {boolean} calculate_ce
16
+ */
17
+ /**
18
+ * Calculates the Standard Effective Temperature (SET). The SET is the
19
+ * temperature of a hypothetical isothermal environment at 50% (rh),
20
+ * <0.1 m/s (20 fpm) average air speed (v), and tr = tdb, in which the
21
+ * total heat loss from the skin of an imaginary occupant wearing
22
+ * clothing, standardized for the activity concerned is the same as
23
+ * that from a person in the actual environment with actual clothing
24
+ * and activity level {@link #ref_10|[10]}.
25
+ * @public
26
+ * @memberof models
27
+ * @docname Standard Effective Temperature (SET)
28
+ *
29
+ * @see {@link set_tmp_array} for a version that supports arrays
30
+ *
31
+ * @param {number} tdb Dry bulb air temperature, default in [°C] in [°F] if `units` = 'IP'.
32
+ * @param {number} tr Mean radiant temperature, default in [°C]
33
+ * @param {number} v Air speed, default in [m/s]
34
+ * @param {number} rh Relative humidity, [%].
35
+ * @param {number} met Metabolic rate, [W/(m2)]
36
+ * @param {number} clo Clothing insulation, [clo]
37
+ * @param {number} [wme=0] External work, [W/(m2)] default 0
38
+ * @param {number} [body_surface_area] Body surface area, default value 1.8258 [m2] in [ft2] if units = ‘IP’
39
+ * @param {number} [p_atm] Atmospheric pressure, default value 101325 [Pa] in [atm] if units = ‘IP’
40
+ * @param {"standing" | "sitting"} [body_position="standing"] Select either “sitting” or “standing”
41
+ * @param {"SI" | "IP"} [units="SI"] Select the SI (International System of Units) or the IP (Imperial Units) system.
42
+ * @param {boolean} [limit_inputs=true] By default, if the inputs are outsude the following limits the function returns nan. If False returns values regardless of the input values.
43
+ * @param {SetTmpKwargs} [kwargs]
44
+ * @returns {number} SET – Standard effective temperature in array, [°C]
45
+ *
46
+ * @example
47
+ * const set = set_tmp(25, 25, 0.1, 50, 1.2, 0.5); // returns 24.3
48
+ */
49
+ function set_tmp(tdb, tr, v, rh, met, clo, wme = 0, body_surface_area, p_atm, body_position = "standing", units = "SI", limit_inputs = true, kwargs = {}) {
50
+ const defaults_kwargs = {
51
+ calculate_ce: false,
52
+ round: true,
53
+ };
54
+ let joint_kwargs = Object.assign(defaults_kwargs, kwargs);
55
+ if (body_surface_area === undefined)
56
+ body_surface_area = units === "SI" ? 1.8258 : 19.65;
57
+ if (p_atm === undefined)
58
+ p_atm = units === "SI" ? 101325 : 1;
59
+ if (units === "IP") {
60
+ const unit_convert = (0, utilities_js_1.units_converter)({
61
+ tdb: tdb,
62
+ tr: tr,
63
+ v: v,
64
+ area: body_surface_area,
65
+ pressure: p_atm,
66
+ }, "IP");
67
+ tdb = unit_convert.tdb;
68
+ tr = unit_convert.tr;
69
+ v = unit_convert.v;
70
+ body_surface_area = unit_convert.area;
71
+ p_atm = unit_convert.pressure;
72
+ }
73
+ let set_tmp = (0, two_nodes_js_1.two_nodes)(tdb, tr, v, rh, met, clo, wme, body_surface_area, p_atm, body_position, undefined, { round: false, calculate_ce: joint_kwargs.calculate_ce }).set;
74
+ if (units === "IP") {
75
+ ({ tmp: set_tmp } = (0, utilities_js_1.units_converter)({ tmp: set_tmp }, "SI"));
76
+ }
77
+ if (limit_inputs) {
78
+ const { tdb: tdb_valid, tr: tr_valid, v: v_valid, met: met_valid, clo: clo_valid, } = (0, utilities_js_1.check_standard_compliance_array)("ASHRAE", {
79
+ tdb: [tdb],
80
+ tr: [tr],
81
+ v: [v],
82
+ met: [met],
83
+ clo: [clo],
84
+ });
85
+ if (isNaN(tdb_valid[0]) ||
86
+ isNaN(tr_valid[0]) ||
87
+ isNaN(v_valid[0]) ||
88
+ isNaN(met_valid[0]) ||
89
+ isNaN(clo_valid[0])) {
90
+ set_tmp = NaN;
91
+ }
92
+ }
93
+ if (joint_kwargs.round) {
94
+ return (0, utilities_js_1.round)(set_tmp, 1);
95
+ }
96
+ return set_tmp;
97
+ }
98
+ exports.set_tmp = set_tmp;
99
+ /**
100
+ * @typedef {Object} SetTmpArrayKwargs - a keywords argument set containing the additional arguments for SET array calculation
101
+ * @property {boolean} [round=true] - round the result of the SET
102
+ * @property {boolean} [calculate_ce=false] - select if SET array is used to calculate Cooling Effect
103
+ * @public
104
+ */
105
+ /**
106
+ * @typedef {Object} SetTmpArrayKwargsRequired
107
+ * @property {boolean} round
108
+ * @property {boolean} calculate_ce
109
+ */
110
+ /**
111
+ *
112
+ * Calculates the SET when the input parameters are arrays. The SET is the
113
+ * temperature of a hypothetical isothermal environment at 50% (rh),
114
+ * <0.1 m/s (20 fpm) average air speed (v), and tr = tdb, in which the
115
+ * total heat loss from the skin of an imaginary occupant wearing
116
+ * clothing, standardized for the activity concerned is the same as
117
+ * that from a person in the actual environment with actual clothing
118
+ * and activity level {@link #ref_10|[10]}.
119
+ * @public
120
+ * @memberof models
121
+ * @docname Standard Effective Temperature (SET) (array version)
122
+ *
123
+ * @see {@link set_tmp} for a version that supports scalar arguments
124
+ *
125
+ * @param {number[]} tdbArray Dry bulb air temperature, default in [°C] in [°F] if `units` = 'IP'.
126
+ * @param {number[]} trArray Mean radiant temperature, default in [°C]
127
+ * @param {number[]} vArray Air speed, default in [m/s]
128
+ * @param {number[]} rhArray Relative humidity, [%].
129
+ * @param {number[]} metArray Metabolic rate, [W/(m2)]
130
+ * @param {number[]} cloArray Clothing insulation, [clo]
131
+ * @param {number[]} [wmeArray] External work, [W/(m2)] default 0
132
+ * @param {number[]} [bodySurfaceArray] Body surface area, default value 1.8258 [m2] in [ft2] if units = ‘IP’
133
+ * @param {number[]} [pAtmArray] Atmospheric pressure, default value 101325 [Pa] in [atm] if units = ‘IP’
134
+ * @param {"standing" | "sitting"} bodyPositionArray Select either “sitting” or “standing”
135
+ * @param {"SI" | "IP"} [units="SI"] Select the SI (International System of Units) or the IP (Imperial Units) system.
136
+ * @param {boolean} [limit_inputs=true] By default, if the inputs are outsude the following limits the function returns nan. If False returns values regardless of the input values.
137
+ * @param {SetTmpKwargs} [kwargs]
138
+ * @returns {number[]} SET Array – Standard effective temperature in array, [°C]
139
+ *
140
+ * @example
141
+ * const set = set_tmp_array([25, 25], [25, 25], [0.1, 0.1], [50, 50], [1.2, 1.2], [0.5, 0.5]); // returns [24.3, 24.3]
142
+ */
143
+ function set_tmp_array(tdbArray, trArray, vArray, rhArray, metArray, cloArray, wmeArray, bodySurfaceArray, pAtmArray, bodyPositionArray, units = "SI", limit_inputs = true, kwargs = {}) {
144
+ const defaults_kwargs = {
145
+ calculate_ce: false,
146
+ round: true,
147
+ };
148
+ let joint_kwargs = Object.assign(defaults_kwargs, kwargs);
149
+ if (wmeArray === undefined) {
150
+ wmeArray = tdbArray.map((_) => 0);
151
+ }
152
+ if (bodyPositionArray === undefined) {
153
+ bodyPositionArray = tdbArray.map((_) => "standing");
154
+ }
155
+ if (bodySurfaceArray === undefined)
156
+ bodySurfaceArray = tdbArray.map((_) => (units === "SI" ? 1.8258 : 19.65));
157
+ if (pAtmArray === undefined)
158
+ pAtmArray = tdbArray.map((_) => (units === "SI" ? 101325 : 1));
159
+ if (units === "IP") {
160
+ const unit_convert = (0, utilities_js_1.units_converter_array)({
161
+ tdb: tdbArray,
162
+ tr: trArray,
163
+ v: vArray,
164
+ area: bodySurfaceArray,
165
+ pressure: pAtmArray,
166
+ }, "IP");
167
+ tdbArray = unit_convert.tdb;
168
+ trArray = unit_convert.tr;
169
+ vArray = unit_convert.v;
170
+ bodySurfaceArray = unit_convert.area;
171
+ pAtmArray = unit_convert.pressure;
172
+ }
173
+ let setArray = (0, two_nodes_js_1.two_nodes_array)(tdbArray, trArray, vArray, rhArray, metArray, cloArray, wmeArray, bodySurfaceArray, pAtmArray, bodyPositionArray, undefined, { round: false, calculate_ce: joint_kwargs.calculate_ce }).set;
174
+ if (units === "IP") {
175
+ const convertedSet = (0, utilities_js_1.units_converter_array)({
176
+ tmp: setArray,
177
+ }, "SI");
178
+ setArray = convertedSet.tmp;
179
+ }
180
+ if (limit_inputs) {
181
+ const { tdb: tdbValid, tr: trValid, v: vValid, met: metValid, clo: cloValid, } = (0, utilities_js_1.check_standard_compliance_array)("ASHRAE", {
182
+ tdb: tdbArray,
183
+ tr: trArray,
184
+ v: vArray,
185
+ met: metArray,
186
+ clo: cloArray,
187
+ });
188
+ for (let index = 0; index < tdbArray.length; index++) {
189
+ if (isNaN(tdbValid[index]) ||
190
+ isNaN(trValid[index]) ||
191
+ isNaN(vValid[index]) ||
192
+ isNaN(metValid[index]) ||
193
+ isNaN(cloValid[index])) {
194
+ setArray[index] = NaN;
195
+ }
196
+ }
197
+ }
198
+ if (joint_kwargs.round) {
199
+ return (0, two_nodes_js_1.roundArray)(setArray, 1);
200
+ }
201
+ return setArray;
202
+ }
203
+ exports.set_tmp_array = set_tmp_array;