This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/README.md +3 -4
- package/admin/i18n/de/translations.json +3 -1
- package/admin/i18n/en/translations.json +3 -1
- package/admin/i18n/es/translations.json +3 -1
- package/admin/i18n/fr/translations.json +3 -1
- package/admin/i18n/it/translations.json +3 -1
- package/admin/i18n/nl/translations.json +3 -1
- package/admin/i18n/pl/translations.json +3 -1
- package/admin/i18n/pt/translations.json +3 -1
- package/admin/i18n/ru/translations.json +3 -1
- package/admin/i18n/uk/translations.json +3 -1
- package/admin/i18n/zh-cn/translations.json +3 -1
- package/admin/index_m.html +11 -1
- package/admin/words.js +134 -133
- package/io-package.json +16 -14
- package/lib/valveControl.js +31 -13
- package/package.json +1 -1
package/io-package.json
CHANGED
|
@@ -1,7 +1,7 @@
|
|
|
1
1
|
{
|
|
2
2
|
"common": {
|
|
3
3
|
"name": "sprinklecontrol",
|
|
4
|
-
"version": "0.2.
|
|
4
|
+
"version": "0.2.16",
|
|
5
5
|
"titleLang": {
|
|
6
6
|
"en": "Sprinkler Control",
|
|
7
7
|
"de": "Sprinklersteuerung",
|
|
@@ -19,6 +19,19 @@
|
|
|
19
19
|
"Dirk Peter <dirk.peter@freenet.de>"
|
|
20
20
|
],
|
|
21
21
|
"news": {
|
|
22
|
+
"0.2.16": {
|
|
23
|
+
"en": "issue #95 Pump lead time added",
|
|
24
|
+
"de": "ausgabe #95 Pumpe Lieferzeit hinzugefügt",
|
|
25
|
+
"ru": "#95 Время работы насоса добавлено",
|
|
26
|
+
"pt": "número de edição #95 Tempo de lançamento da bomba adicionado",
|
|
27
|
+
"nl": "nummer #95 Pump doorlooptijd toegevoegd",
|
|
28
|
+
"fr": "numéro 95 Temps d'avance de la pompe ajouté",
|
|
29
|
+
"it": "numero #95 Pump lead time aggiunto",
|
|
30
|
+
"es": "#95 Tiempo de inicio de bomba añadido",
|
|
31
|
+
"pl": "wydanie # 95 Dodany czas ołowiu pompy",
|
|
32
|
+
"uk": "problem #95 Насос додано час",
|
|
33
|
+
"zh-cn": "增加了泵前准备时间"
|
|
34
|
+
},
|
|
22
35
|
"0.2.15": {
|
|
23
36
|
"en": "Readme updated\nFixed an error when switching off with autoOnOff\nioBroker-Bot [W028]",
|
|
24
37
|
"de": "Reader aktualisiert\nFehler beim Ausschalten mit autoOnOff behoben\nioBroker-Bot [W028]",
|
|
@@ -96,19 +109,6 @@
|
|
|
96
109
|
"pl": "- nawadnianie ręczne ograniczone do maksymalnie 100%; - Naprawiono błąd wiadomości WhatsApp",
|
|
97
110
|
"uk": "- ручний полив обмежений максимум на 100%; - Виправлено повідомлення про помилку WhatsApp",
|
|
98
111
|
"zh-cn": "- 手动浇水限制为最大 100%; - 错误whatsapp消息已修复"
|
|
99
|
-
},
|
|
100
|
-
"0.2.9": {
|
|
101
|
-
"en": "Bug initialization routine",
|
|
102
|
-
"de": "Bug-Initialisierungsroutine",
|
|
103
|
-
"ru": "Процедура инициализации ошибки",
|
|
104
|
-
"pt": "Rotina de inicialização de bugs",
|
|
105
|
-
"nl": "Bug initialisatie routine",
|
|
106
|
-
"fr": "Routine d'initialisation de bogue",
|
|
107
|
-
"it": "Routine di inizializzazione dei bug",
|
|
108
|
-
"es": "Rutina de inicialización de errores",
|
|
109
|
-
"pl": "Procedura inicjowania błędów",
|
|
110
|
-
"uk": "Процедура ініціалізації помилок",
|
|
111
|
-
"zh-cn": "错误初始化例程"
|
|
112
112
|
}
|
|
113
113
|
},
|
|
114
114
|
"desc": {
|
|
@@ -172,9 +172,11 @@
|
|
|
172
172
|
"switchingDistance": "300",
|
|
173
173
|
"triggerMainPump": "hm-rpc.0.MEQ1234567.1.STATE",
|
|
174
174
|
"triggerMainPumpPower": "2000",
|
|
175
|
+
"mainPumpLeadTime": "15",
|
|
175
176
|
"cisternSettings": false,
|
|
176
177
|
"triggerCisternPump": "",
|
|
177
178
|
"triggerCisternPumpPower": "1800",
|
|
179
|
+
"cisternPumpLeadTime": "10",
|
|
178
180
|
"actualValueLevel": "",
|
|
179
181
|
"triggerMinCisternLevel": "25",
|
|
180
182
|
"wateringStartTime": "livingGoldenHourEnd",
|
package/lib/valveControl.js
CHANGED
|
@@ -176,12 +176,15 @@ function boostKill (sprinkleID) {
|
|
|
176
176
|
|
|
177
177
|
/**
|
|
178
178
|
* Schaltintervall der Ventile, Schaltabstand ist in der Config hinterlegt
|
|
179
|
+
*
|
|
180
|
+
* @param delay wenn keine Zeit eingegeben ist, wird der Schaltabstand der Config verwendet
|
|
179
181
|
*/
|
|
180
|
-
const valveDelay = () => {
|
|
182
|
+
const valveDelay = (delay = parseInt(adapter.config.switchingDistance)) => {
|
|
181
183
|
return new Promise (
|
|
182
|
-
resolve => setTimeout (resolve,
|
|
184
|
+
resolve => setTimeout (resolve, delay)
|
|
183
185
|
);
|
|
184
186
|
};
|
|
187
|
+
|
|
185
188
|
/**
|
|
186
189
|
* Ausschalten der Ventile mit Schaltabstand
|
|
187
190
|
*
|
|
@@ -219,7 +222,7 @@ const switchTheValvesOffOn = async (threadList, parallel) => {
|
|
|
219
222
|
}
|
|
220
223
|
}
|
|
221
224
|
if (currentPumpUse.pumpName !== '') {
|
|
222
|
-
setPumpOnOff(parallel > 0);
|
|
225
|
+
await setPumpOnOff(parallel > 0);
|
|
223
226
|
await valveDelay ();
|
|
224
227
|
}
|
|
225
228
|
if (adapter.config.triggerControlVoltage) {
|
|
@@ -496,6 +499,7 @@ function setActualPump () {
|
|
|
496
499
|
currentPumpUse.pumpCistern = false;
|
|
497
500
|
currentPumpUse.pumpName = adapter.config.triggerMainPump || '';
|
|
498
501
|
currentPumpUse.pumpPower = parseInt(adapter.config.triggerMainPumpPower);
|
|
502
|
+
currentPumpUse.leadTime = parseInt(adapter.config.mainPumpLeadTime)*1000 || 1000;
|
|
499
503
|
adapter.setForeignState(currentPumpUse.pumpName, {
|
|
500
504
|
val: true,
|
|
501
505
|
ack: false
|
|
@@ -531,6 +535,7 @@ function setActualPump () {
|
|
|
531
535
|
currentPumpUse.pumpCistern = true;
|
|
532
536
|
currentPumpUse.pumpName = adapter.config.triggerCisternPump || '';
|
|
533
537
|
currentPumpUse.pumpPower = parseInt(adapter.config.triggerCisternPumpPower);
|
|
538
|
+
currentPumpUse.leadTime = parseInt(adapter.config.cisternPumpLeadTime)*1000 || 1000;
|
|
534
539
|
adapter.setState('control.restFlow', {
|
|
535
540
|
val: `${currentPumpUse.pumpPower} (${currentPumpUse.pumpPower} Zisterne)`,
|
|
536
541
|
ack: true
|
|
@@ -544,6 +549,7 @@ function setActualPump () {
|
|
|
544
549
|
currentPumpUse.pumpCistern = false;
|
|
545
550
|
currentPumpUse.pumpName = adapter.config.triggerMainPump || '';
|
|
546
551
|
currentPumpUse.pumpPower = parseInt(adapter.config.triggerMainPumpPower);
|
|
552
|
+
currentPumpUse.leadTime = parseInt(adapter.config.mainPumpLeadTime)*1000 || 1000;
|
|
547
553
|
adapter.setState('control.restFlow', {
|
|
548
554
|
val: `${currentPumpUse.pumpPower} (${currentPumpUse.pumpPower} Grundwasser)`,
|
|
549
555
|
ack: true
|
|
@@ -568,21 +574,23 @@ function setActualPump () {
|
|
|
568
574
|
*
|
|
569
575
|
* @param pumpOnOff ; Pumpe on = true
|
|
570
576
|
*/
|
|
571
|
-
|
|
577
|
+
const setPumpOnOff = async (pumpOnOff) => {
|
|
572
578
|
if (currentPumpUse.pumpName !== '') {
|
|
573
|
-
|
|
574
|
-
|
|
579
|
+
try {
|
|
580
|
+
const curPumpState = await adapter.getForeignStateAsync(currentPumpUse.pumpName);
|
|
581
|
+
if (curPumpState) {
|
|
575
582
|
if (pumpOnOff) {
|
|
576
|
-
if (
|
|
583
|
+
if (curPumpState.val === false) {
|
|
577
584
|
adapter.setForeignState(currentPumpUse.pumpName, {
|
|
578
585
|
val: true,
|
|
579
586
|
ack: false
|
|
580
587
|
});
|
|
581
588
|
currentPumpUse.enable = true;
|
|
582
589
|
adapter.log.info('Set (pump) on');
|
|
590
|
+
await valveDelay(currentPumpUse.leadTime);
|
|
583
591
|
}
|
|
584
592
|
} else {
|
|
585
|
-
if (
|
|
593
|
+
if (curPumpState.val !== false) {
|
|
586
594
|
adapter.setForeignState(currentPumpUse.pumpName, {
|
|
587
595
|
val: false,
|
|
588
596
|
ack: false
|
|
@@ -591,10 +599,10 @@ function setPumpOnOff(pumpOnOff) {
|
|
|
591
599
|
adapter.log.info('Set (pump) off');
|
|
592
600
|
}
|
|
593
601
|
}
|
|
594
|
-
} else if (err) {
|
|
595
|
-
adapter.log.error(`triggerMainPump ${currentPumpUse.pumpName} is not available (ist nicht erreichbar): ${err}`);
|
|
596
602
|
}
|
|
597
|
-
})
|
|
603
|
+
} catch (error) {
|
|
604
|
+
adapter.log.error(`triggerMainPump ${currentPumpUse.pumpName} is not available (ist nicht erreichbar): ${error}`);
|
|
605
|
+
}
|
|
598
606
|
}
|
|
599
607
|
} // End setPumpOnOff
|
|
600
608
|
|
|
@@ -690,6 +698,7 @@ const valveControl = {
|
|
|
690
698
|
currentPumpUse.pumpCistern = false;
|
|
691
699
|
currentPumpUse.pumpName = adapter.config.triggerMainPump || '';
|
|
692
700
|
currentPumpUse.pumpPower = parseInt(adapter.config.triggerMainPumpPower) || 0;
|
|
701
|
+
currentPumpUse.leadTime = parseInt(adapter.config.mainPumpLeadTime)*1000 || 1000;
|
|
693
702
|
maxParallel = parseInt(adapter.config.maximumParallelValves);
|
|
694
703
|
/* Objekt control.restFlow befüllen */
|
|
695
704
|
adapter.setState('control.restFlow', {
|
|
@@ -783,6 +792,15 @@ const valveControl = {
|
|
|
783
792
|
});
|
|
784
793
|
addDone = true; // Sprinkle found
|
|
785
794
|
adapter.log.debug(`update ID: ${entry.sprinkleName} new time: ${addTime(res.wateringTime)}`);
|
|
795
|
+
// Wenn aktueller Spränger im BoostOn ausgeschaltet werden soll (ersten 30s)
|
|
796
|
+
if (boostOn
|
|
797
|
+
&& myConfig.config[res.sprinkleID].booster
|
|
798
|
+
&& entry.wateringTime <= 0
|
|
799
|
+
) {
|
|
800
|
+
boostKill(res.sprinkleID);
|
|
801
|
+
boostReady = true;
|
|
802
|
+
adapter.log.debug(`ID: ${res.sprinkleName} BoostKill Sprinkle Off: boostReady = ${boostReady}`);
|
|
803
|
+
}
|
|
786
804
|
break;
|
|
787
805
|
}
|
|
788
806
|
}
|
|
@@ -831,8 +849,8 @@ const valveControl = {
|
|
|
831
849
|
soilMoisture15s: 15 * (myConfig.config[res.sprinkleID].soilMoisture.maxIrrigation - myConfig.config[res.sprinkleID].soilMoisture.triggersIrrigation)
|
|
832
850
|
/ (60 * myConfig.config[res.sprinkleID].wateringTime),
|
|
833
851
|
times: {
|
|
834
|
-
boostTime1: null, // boost start
|
|
835
|
-
boostTime2: null, // boost ende
|
|
852
|
+
boostTime1: null, // boost start in die Zwangspause schicken in 0,25s
|
|
853
|
+
boostTime2: null, // boost ende aus der Zwangspause holen nach 31s
|
|
836
854
|
}, // hinterlegen der verschiedenen Zeiten von timeout für gezieltes späteres löschen
|
|
837
855
|
id: threadList.length || 0,
|
|
838
856
|
};
|