iobroker.sigenergy 2.3.1 → 2.3.2

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/README.md CHANGED
@@ -153,6 +153,9 @@ Status and power readings for the DC charger.
153
153
 
154
154
  ## Changelog
155
155
 
156
+ ### 2.3.2 (2026-06-10)
157
+ - (ssbingo) fix: show 'pre-V2.6' instead of 'unknown' when device responds but has no extended plant registers; add per-probe debug log with Modbus exception message
158
+
156
159
  ### 2.3.1 (2026-06-10)
157
160
  - (ssbingo) feat: detect Modbus protocol level on startup by probing registers 30088/30200/30228/30286; read firmware version (30525); log result and store as info.protocolLevel state
158
161
 
package/io-package.json CHANGED
@@ -1,20 +1,20 @@
1
1
  {
2
2
  "common": {
3
3
  "name": "sigenergy",
4
- "version": "2.3.1",
4
+ "version": "2.3.2",
5
5
  "news": {
6
- "2.3.1": {
7
- "en": "(ssbingo) feat: detect Modbus protocol level on startup by probing registers 30088/30200/30228/30286; read firmware version (30525); log result and store as info.protocolLevel state",
8
- "de": "(ssbingo) feat: Modbus-Protokollebene beim Start durch Probe von Registern 30088/30200/30228/30286 erkennen; Firmware-Version (30525) lesen; Ergebnis loggen und als info.protocolLevel-State speichern",
9
- "ru": "(ssbingo) feat: определение уровня протокола Modbus при запуске путём опроса регистров 30088/30200/30228/30286; чтение версии прошивки (30525); журналирование результата и сохранение в состояние info.protocolLevel",
10
- "pt": "(ssbingo) feat: detectar nível do protocolo Modbus no arranque sondando registos 30088/30200/30228/30286; ler versão de firmware (30525); registar resultado e guardar como estado info.protocolLevel",
11
- "nl": "(ssbingo) feat: Modbus-protocolniveau bij opstarten detecteren door registers 30088/30200/30228/30286 te sonderen; firmwareversie (30525) lezen; resultaat loggen en opslaan als info.protocolLevel-state",
12
- "fr": "(ssbingo) feat: détection du niveau de protocole Modbus au démarrage en sondant les registres 30088/30200/30228/30286 ; lecture de la version firmware (30525) ; journalisation du résultat et stockage dans l'état info.protocolLevel",
13
- "it": "(ssbingo) feat: rilevamento del livello del protocollo Modbus all'avvio sondando i registri 30088/30200/30228/30286; lettura della versione firmware (30525); registrazione del risultato e salvataggio come stato info.protocolLevel",
14
- "es": "(ssbingo) feat: detectar nivel de protocolo Modbus en el arranque sondeando registros 30088/30200/30228/30286; leer versión de firmware (30525); registrar resultado y almacenar como estado info.protocolLevel",
15
- "pl": "(ssbingo) feat: wykrywanie poziomu protokołu Modbus przy uruchomieniu przez próbkowanie rejestrów 30088/30200/30228/30286; odczyt wersji firmware (30525); logowanie wyniku i zapis jako stan info.protocolLevel",
16
- "uk": "(ssbingo) feat: виявлення рівня протоколу Modbus при запуску шляхом зондування регістрів 30088/30200/30228/30286; зчитування версії прошивки (30525); журналювання результату та збереження як стан info.protocolLevel",
17
- "zh-cn": "(ssbingo) feat: 启动时通过探测寄存器 30088/30200/30228/30286 检测 Modbus 协议级别;读取固件版本(30525);记录结果并存储为 info.protocolLevel 状态"
6
+ "2.3.2": {
7
+ "en": "(ssbingo) fix: show 'pre-V2.6' instead of 'unknown' when device responds but has no extended plant registers; add per-probe debug log with Modbus exception message",
8
+ "de": "(ssbingo) fix: 'pre-V2.6' statt 'unknown' wenn Gerät antwortet aber keine erweiterten Plant-Register hat; Debug-Log pro Probe mit Modbus-Exception-Meldung ergänzt",
9
+ "ru": "(ssbingo) fix: отображать 'pre-V2.6' вместо 'unknown' если устройство отвечает, но не имеет расширенных регистров plant; добавлено отладочное сообщение на каждый зонд с кодом Modbus-исключения",
10
+ "pt": "(ssbingo) fix: mostrar 'pre-V2.6' em vez de 'unknown' quando o dispositivo responde mas não tem registos plant estendidos; log de debug por sonda com mensagem de excepção Modbus",
11
+ "nl": "(ssbingo) fix: 'pre-V2.6' tonen in plaats van 'unknown' als het apparaat reageert maar geen uitgebreide plant-registers heeft; debug-log per probe met Modbus-uitzonderingsmelding",
12
+ "fr": "(ssbingo) fix: afficher 'pre-V2.6' au lieu de 'unknown' si l'appareil répond mais n'a pas de registres plant étendus ; log de débogage par sonde avec message d'exception Modbus",
13
+ "it": "(ssbingo) fix: mostrare 'pre-V2.6' invece di 'unknown' quando il dispositivo risponde ma non ha registri plant estesi; log di debug per sonda con messaggio di eccezione Modbus",
14
+ "es": "(ssbingo) fix: mostrar 'pre-V2.6' en lugar de 'unknown' cuando el dispositivo responde pero no tiene registros plant extendidos; log de depuración por sonda con mensaje de excepción Modbus",
15
+ "pl": "(ssbingo) fix: pokazywać 'pre-V2.6' zamiast 'unknown' gdy urządzenie odpowiada ale nie ma rozszerzonych rejestrów plant; log debugowania na sondę z komunikatem wyjątku Modbus",
16
+ "uk": "(ssbingo) fix: відображати 'pre-V2.6' замість 'unknown' коли пристрій відповідає, але не має розширених регістрів plant; журнал налагодження на зонд з повідомленням про виняток Modbus",
17
+ "zh-cn": "(ssbingo) fix: 当设备响应但无扩展 plant 寄存器时显示 'pre-V2.6' 而非 'unknown';为每个探针添加含 Modbus 异常信息的调试日志"
18
18
  }
19
19
  },
20
20
  "titleLang": {
package/main.js CHANGED
@@ -522,7 +522,8 @@ class Sigenergy extends utils.Adapter {
522
522
  try {
523
523
  await this.modbus.readInputRegisters(plantId, probe.addr, 1);
524
524
  detectedLevel = probe.level;
525
- } catch {
525
+ } catch (err) {
526
+ this.log.debug(`[protocolProbe] addr=${probe.addr} (${probe.level}): ${err.message}`);
526
527
  break;
527
528
  }
528
529
  }
@@ -535,7 +536,7 @@ class Sigenergy extends utils.Adapter {
535
536
  // not critical
536
537
  }
537
538
 
538
- const levelStr = detectedLevel ? `>=${detectedLevel}` : 'unknown';
539
+ const levelStr = detectedLevel ? `>=${detectedLevel}` : 'pre-V2.6';
539
540
  this.log.info(`Detected protocol level: ${levelStr} (firmware: ${firmwareVersion})`);
540
541
  await this.setStateAsync('info.protocolLevel', { val: levelStr, ack: true });
541
542
  }
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "iobroker.sigenergy",
3
- "version": "2.3.1",
3
+ "version": "2.3.2",
4
4
  "description": "ioBroker adapter for Sigenergy solar energy systems via Modbus TCP/RTU",
5
5
  "author": {
6
6
  "name": "ssbingo",