iobroker.senec 1.3.5-beta → 1.3.8
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/README.md +12 -1
- package/io-package.json +37 -54
- package/lib/state_attr.js +125 -13
- package/lib/state_trans.js +42 -6
- package/main.js +3 -2
- package/package.json +23 -23
package/README.md
CHANGED
|
@@ -370,7 +370,18 @@ This channel contains calculated values. Currently these are day/week/month/year
|
|
|
370
370
|
*Read-only number, which designates the number of wallbox [0..3]. This is only available on systems with configured wallboxes.*
|
|
371
371
|
|
|
372
372
|
## Changelog
|
|
373
|
-
### 1.3.
|
|
373
|
+
### 1.3.8 (NoBl)
|
|
374
|
+
* Removed (unnecessary) admin tab
|
|
375
|
+
|
|
376
|
+
### 1.3.7 (NoBl, noffycws, git-ZeR0)
|
|
377
|
+
* Updates to state translations (new values when SENEC turned off appliances)
|
|
378
|
+
* Added state definitions
|
|
379
|
+
* Added high priority datapoints: temperatures, voltages, ... to better monitor safety relevant data
|
|
380
|
+
|
|
381
|
+
### 1.3.6 (NoBl)
|
|
382
|
+
* Fixed log.warning error
|
|
383
|
+
|
|
384
|
+
### 1.3.5 (NoBl)
|
|
374
385
|
* Added more state attributes (if you have updated descriptions or anything, please open an issue!)
|
|
375
386
|
* Workaround in case SENEC reports bogus request data
|
|
376
387
|
|
package/io-package.json
CHANGED
|
@@ -1,8 +1,44 @@
|
|
|
1
1
|
{
|
|
2
2
|
"common": {
|
|
3
3
|
"name": "senec",
|
|
4
|
-
"version": "1.3.
|
|
4
|
+
"version": "1.3.8",
|
|
5
5
|
"news": {
|
|
6
|
+
"1.3.8": {
|
|
7
|
+
"en": "Removed (unnecessary) admin tab.",
|
|
8
|
+
"de": "(Unnötigen) Admin-Tab entfernt.",
|
|
9
|
+
"ru": "Удаленная (необходимая) админ таб.",
|
|
10
|
+
"pt": "Removido (desnecessário) guia de administração.",
|
|
11
|
+
"nl": "Admin Tab.",
|
|
12
|
+
"fr": "Supprimé (non nécessaire) onglet administrateur.",
|
|
13
|
+
"it": "Rimossa (non necessaria) scheda di amministrazione.",
|
|
14
|
+
"es": "Tapa de administración extraída (innecesaria).",
|
|
15
|
+
"pl": "Przemieniona (nieunikniona) tablica adminowa.",
|
|
16
|
+
"zh-cn": "删除(无必要)专注表。."
|
|
17
|
+
},
|
|
18
|
+
"1.3.7": {
|
|
19
|
+
"en": "Updates to state translations (new values when SENEC turned off appliances), Added state definitions, Added high priority datapoints: temperatures, voltages, ... to better monitor safety relevant data",
|
|
20
|
+
"de": "Aktualisierungen der State Übersetzungen (neue Werte durch die SENEC Problematik), Zustandsdefinitionen hinzugefügt, Datenpunkte mit hoher Priorität ergänzt: Temperaturen, Spannungen, ... um sicherheitsrelevante Daten besser zu überwachen",
|
|
21
|
+
"ru": "Обновления государственных переводов (новые значения, когда SENEC отключила бытовую технику), Добавлены государственные определения, Добавлены высокие приоритетные данные: температуры, напряжения, ... для лучшего контроля безопасности соответствующих данных",
|
|
22
|
+
"pt": "Atualizações às traduções estaduais (novos valores quando o SENEC desligou aparelhos), definições de estado adicionadas, pontos de dados de alta prioridade adicionados: temperaturas, tensões, ... para melhor monitorar dados relevantes de segurança",
|
|
23
|
+
"nl": "Vertaling:",
|
|
24
|
+
"fr": "Mises à jour des traductions d'état (nouvelles valeurs lorsque SENEC a éteint les appareils), Définitions d'état, Ajout de points de données hautement prioritaires: températures, tensions, ... pour mieux surveiller les données pertinentes de sécurité",
|
|
25
|
+
"it": "Aggiornamenti alle traduzioni di stato (nuovi valori quando SENEC ha spento gli elettrodomestici), Aggiunte definizioni di stato, Aggiunto datapoint ad alta priorità: temperature, tensioni, ... per monitorare meglio la sicurezza dati rilevanti",
|
|
26
|
+
"es": "Actualizaciones a las traducciones estatales (nuevos valores cuando SENEC apagó electrodomésticos), definiciones de estado agregadas, Puntos de datos de alta prioridad añadidos: temperaturas, voltajes, ... para monitorear mejor la seguridad datos relevantes",
|
|
27
|
+
"pl": "Ulepszenia do tłumaczenia stanu (nowe wartości, kiedy SENEC odwrócił urządzenia), definicje państwowe, dodane wysoko priorytetowe punkty danych: temperatury, napięcia, ... aby lepiej monitorować odpowiednie dane danych",
|
|
28
|
+
"zh-cn": "国家翻译的更新(新值在中欧经会脱离了配件),加上国家定义,加上高度优先的数据点:温度,火山,......以更好地监测安全相关数据"
|
|
29
|
+
},
|
|
30
|
+
"1.3.6": {
|
|
31
|
+
"en": "fixed log.warning error",
|
|
32
|
+
"de": "log.warning-Fehler behoben",
|
|
33
|
+
"ru": "исправлена ошибка log.warning",
|
|
34
|
+
"pt": "erro log.warning corrigido",
|
|
35
|
+
"nl": "vaste log.waarschuwingsfout",
|
|
36
|
+
"fr": "correction de l'erreur log.warning",
|
|
37
|
+
"it": "errore log.warning corretto",
|
|
38
|
+
"es": "error de advertencia de registro fijo",
|
|
39
|
+
"pl": "naprawiony błąd log.warning",
|
|
40
|
+
"zh-cn": "修复了 log.warning 错误"
|
|
41
|
+
},
|
|
6
42
|
"1.3.5-beta": {
|
|
7
43
|
"en": "Added more state attributes (if you have updated descriptions or anything, please open an issue!), Workaround in case SENEC reports bogus request data",
|
|
8
44
|
"de": "Weitere Beschreibungen für Datenpunkte hinzugefügt (wenn Sie hierzu Updates, fehlende Datenpunkte, etc haben, öffnen Sie bitte ein Ticket auf github; Problemumgehung für den Fall, dass SENEC gefälschte Anfragedaten meldet",
|
|
@@ -50,42 +86,6 @@
|
|
|
50
86
|
"es": "Autarquía sin decimales (de nuevo). Están provocando más actualizaciones de las que realmente necesitamos. Los valores de autarquía ya no se restablecerán a 0 al cambiar el período de tiempo (día, semana, ...). De todos modos, se calculan sobre la base de valores de referencia. Asegurarse de que solo se definan así los valores que el usuario puede cambiar (el atributo cambia en la próxima actualización del valor)",
|
|
51
87
|
"pl": "Autarkia bez miejsc dziesiętnych (ponownie). Powodują więcej aktualizacji, niż naprawdę potrzebujemy. Wartości autarkii nie będą już resetowane do 0 przy zmianie przedziału czasowego (dzień, tydzień, ...). Są one i tak obliczane na podstawie wartości referencyjnych. Zapewnienie, że tylko wartości, które mają być zmieniane przez użytkownika, są tak zdefiniowane (atrybut zmienia się przy następnej aktualizacji wartości)",
|
|
52
88
|
"zh-cn": "再次没有小数位的Autarky。它们造成的更新超出了我们的实际需要。 Autarky值将不会在时间范围(天,周,...)更改时重置为0。无论如何,它们都是基于参考值计算的。确保仅定义要由用户更改的值(在值的下一次更新时归因于更改)"
|
|
53
|
-
},
|
|
54
|
-
"1.3.1": {
|
|
55
|
-
"en": "(NoBl) Added calculation of autarky for day/week/month/year",
|
|
56
|
-
"de": "(NoBl) Berechnung der Autarkie für Tag / Woche / Monat / Jahr hinzugefügt",
|
|
57
|
-
"ru": "(NoBl) Добавлен расчет автаркии на день / неделю / месяц / год",
|
|
58
|
-
"pt": "(NoBl) Adicionado cálculo de autarquia para dia / semana / mês / ano",
|
|
59
|
-
"nl": "(NoBl) Berekening van autarkie toegevoegd voor dag / week / maand / jaar",
|
|
60
|
-
"fr": "(NoBl) Ajout du calcul de l'autarcie pour jour / semaine / mois / année",
|
|
61
|
-
"it": "(NoBl) Aggiunto il calcolo dell'autarchia per giorno / settimana / mese / anno",
|
|
62
|
-
"es": "(NoBl) Cálculo agregado de autarquía para día / semana / mes / año",
|
|
63
|
-
"pl": "(NoBl) Dodano obliczanie autarkii dla dnia / tygodnia / miesiąca / roku",
|
|
64
|
-
"zh-cn": "(NoBl)添加了针对日/周/月/年的自给自足计算"
|
|
65
|
-
},
|
|
66
|
-
"1.3.0": {
|
|
67
|
-
"en": "(NoBl) Rewrote translations handling and added translations for wallbox status. Translated status get an extra datapoint with _Text as postfix. Former translations that didn't add an extra dp will now revert to their numeric representation and add the _Text DP. translations are now handled via lib/state_trans.js for all 3 languages available in the senec system (german, english, italian).",
|
|
68
|
-
"de": "(NoBl) Übersetzungshandling neu designed und Übersetzungen für den Wallbox-Status hinzugefügt. Der übersetzte Status erhält einen zusätzlichen Datenpunkt mit _Text als Postfix. Frühere Übersetzungen ohne zusätzlichen DP werden auf ihren numerischen Wert zurückgesetzt und es wird der DP mit Postfix ergänzt. Übersetzungen werden jetzt über lib / state_trans.js für alle 3 im senec-System verfügbaren Sprachen (Deutsch, Englisch, Italienisch) abgewickelt.",
|
|
69
|
-
"ru": "(NoBl) Переписана обработка переводов и добавлены переводы для статуса wallbox. Переведенный статус получает дополнительную точку данных с _Text в качестве постфикса. Прежние переводы, которые не добавляли дополнительный dp, теперь вернутся к своему числовому представлению и добавят _Text DP. переводы теперь выполняются через lib / state_trans.js для всех 3 языков, доступных в системе senec (немецкий, английский, итальянский).",
|
|
70
|
-
"pt": "(NoBl) Manipulação de traduções reescritas e traduções adicionadas para status de wallbox. O status traduzido obtém um ponto de dados extra com _Text como postfix. As traduções anteriores que não adicionaram um dp extra irão agora reverter para sua representação numérica e adicionar o _Text DP. as traduções agora são feitas via lib / state_trans.js para todos os 3 idiomas disponíveis no sistema senec (alemão, inglês, italiano).",
|
|
71
|
-
"nl": "(NoBl) Verwerking van vertalingen herschreven en vertalingen toegevoegd voor wallbox-status. De vertaalde status krijgt een extra datapunt met _Text als postfix. Voormalige vertalingen die geen extra dp hebben toegevoegd, zullen nu terugkeren naar hun numerieke weergave en de _Text DP toevoegen. vertalingen worden nu afgehandeld via lib / state_trans.js voor alle 3 talen die beschikbaar zijn in het senec-systeem (duits, engels, italiaans).",
|
|
72
|
-
"fr": "(NoBl) Réécriture de la gestion des traductions et ajout de traductions pour le statut de la wallbox. Le statut traduit obtient un point de données supplémentaire avec _Text comme suffixe. Les anciennes traductions qui n'ajoutaient pas de dp supplémentaire reviendront maintenant à leur représentation numérique et ajouteront le _Text DP. les traductions sont désormais gérées via lib / state_trans.js pour les 3 langues disponibles dans le système senec (allemand, anglais, italien).",
|
|
73
|
-
"it": "(NoBl) Gestione delle traduzioni riscritta e traduzioni aggiunte per lo stato della wallbox. Lo stato tradotto ottiene un datapoint aggiuntivo con _Text come suffisso. Le precedenti traduzioni che non aggiungevano un dp extra torneranno ora alla loro rappresentazione numerica e aggiungeranno _Text DP. le traduzioni sono ora gestite tramite lib / state_trans.js per tutte e 3 le lingue disponibili nel sistema senec (tedesco, inglese, italiano).",
|
|
74
|
-
"es": "(NoBl) Reescribió el manejo de traducciones y agregó traducciones para el estado de wallbox. El estado traducido obtiene un punto de datos adicional con _Text como sufijo. Las traducciones anteriores que no agregaron un dp adicional ahora volverán a su representación numérica y agregarán el _Text DP. las traducciones ahora se manejan a través de lib / state_trans.js para los 3 idiomas disponibles en el sistema senec (alemán, inglés, italiano).",
|
|
75
|
-
"pl": "(NoBl) Przepisano obsługę tłumaczeń i dodano tłumaczenia dla statusu Wallbox. Status przetłumaczony otrzymuje dodatkowy punkt danych z _Textem jako postfiksem. Wcześniejsze tłumaczenia, które nie dodały dodatkowego dp, teraz powrócą do swojej reprezentacji numerycznej i dodają _Text DP. tłumaczenia są teraz obsługiwane przez lib / state_trans.js dla wszystkich 3 języków dostępnych w systemie senec (niemiecki, angielski, włoski).",
|
|
76
|
-
"zh-cn": "(NoBl)重新编写了翻译处理并添加了关于墙盒状态的翻译。转换后的状态以_Text作为后缀获得一个额外的数据点。以前没有添加额外dp的翻译现在将恢复为其数字表示形式,并添加_Text DP。现在可以通过lib / state_trans.js处理senec系统中所有3种语言(德语,英语,意大利语)的翻译。"
|
|
77
|
-
},
|
|
78
|
-
"1.2.0": {
|
|
79
|
-
"en": "(NoBl) Added datapoints for: PM1OBJ1, PM1OBJ2, EG_CONTROL, RTC, PM1, TEMPMEASURE, DEBUG, SOCKETS, CASC, WALLBOX, CONNX50, STECA (please report wrong / missing units).; Adapter now calculates day/week/month/year-values for: STATISTIC.LIVE_GRID_EXPORT, STATISTIC.LIVE_GRID_IMPORT, STATISTIC.LIVE_HOUSE_CONS, STATISTIC.LIVE_PV_GEN, STATISTIC.LIVE_BAT_CHARGE_MASTER, STATISTIC.LIVE_BAT_DISCHARGE_MASTER. Calculated values can be found below the _calc. datapoint. Information about daily values was removed from the API by SENEC in the past. So here we go again ...",
|
|
80
|
-
"de": "(NoBl) Datenpunkte hinzugefügt für: PM1OBJ1, PM1OBJ2, EG_CONTROL, RTC, PM1, TEMPMEASURE, DEBUG, STECKDOSEN, CASC, WALLBOX, CONNX50, STECA (bitte falsche / fehlende Einheiten melden); Der Adapter berechnet jetzt Tag / Woche / Monat / Jahr-Werte für: STATISTIC.LIVE_GRID_EXPORT, STATISTIC.LIVE_GRID_IMPORT, STATISTIC.LIVE_HOUSE_CONS, STATISTIC.LIVE_PV_GEN, STATISTIC.LIVE_BAT_CHARGE_MASTER, STATISTIC_L_. Berechnete Werte befinden sich unter dem _calc. Datenpunkt. Informationen zu Tageswerten wurden in der Vergangenheit von SENEC aus der API entfernt. Jetzt sind sie wieder da ...",
|
|
81
|
-
"ru": "(NoBl) Добавлены точки данных для: PM1OBJ1, PM1OBJ2, EG_CONTROL, RTC, PM1, TEMPMEASURE, DEBUG, SOCKETS, CASC, WALLBOX, CONNX50, STECA (сообщите неправильные / отсутствующие блоки) .; Теперь адаптер вычисляет значения дня / недели / месяца / года для: STATISTIC.LIVE_GRID_EXPORT, STATISTIC.LIVE_GRID_IMPORT, STATISTIC.LIVE_HOUSE_CONS, STATISTIC.LIVE_PV_GEN, STATISTIC.LIVE_BAT_CHARGE_MASTER_MASTER_DISCHARGE_MASTER_MASTER_STATISTIC_BAT_CHARGE_MASTER_MASTER_SCHARGE_MASTER_MASTER_SCHARGE_MASTER_SCHARGE_MASTER_SCHARGE_MASTER_SCHARGE_MASTER. Расчетные значения можно найти под _calc. датапоинт. Информация о ежедневных значениях была удалена из API SENEC в прошлом. Итак, мы снова ...",
|
|
82
|
-
"pt": "(NoBl) Adicionados pontos de dados para: PM1OBJ1, PM1OBJ2, EG_CONTROL, RTC, PM1, TEMPMEASURE, DEBUG, SOCKETS, CASC, WALLBOX, CONNX50, STECA (relatar unidades erradas / ausentes) .; O adaptador agora calcula os valores de dia / semana / mês / ano para: STATISTIC.LIVE_GRID_EXPORT, STATISTIC.LIVE_GRID_IMPORT, STATISTIC.LIVE_HOUSE_CONS, STATISTIC.LIVE_PV_GEN, STATISTIC.LIVE_BAT_CHARGE_MASTER, STATISTIC.LIVE_BAT_DISCHAR. Os valores calculados podem ser encontrados abaixo de _calc. datapoint. As informações sobre os valores diários foram removidas da API pelo SENEC no passado. Então, aqui vamos nós outra vez ...",
|
|
83
|
-
"nl": "(NoBl) Datapunten toegevoegd voor: PM1OBJ1, PM1OBJ2, EG_CONTROL, RTC, PM1, TEMPMEASURE, DEBUG, SOCKETS, CASC, WALLBOX, CONNX50, STECA (gelieve verkeerde / ontbrekende eenheden te melden) .; Adapter berekent nu dag / week / maand / jaar-waarden voor: STATISTIC.LIVE_GRID_EXPORT, STATISTIC.LIVE_GRID_IMPORT, STATISTIC.LIVE_HOUSE_CONS, STATISTIC.LIVE_PV_GEN, STATISTIC.LIVE_BAT_CHARGE_MASTER, STATISTIC_MASTER. Berekende waarden zijn te vinden onder de _calc. data punt. Informatie over dagelijkse waarden is in het verleden door SENEC uit de API verwijderd. Dus hier gaan we weer ...",
|
|
84
|
-
"fr": "(NoBl) Ajout de points de données pour: PM1OBJ1, PM1OBJ2, EG_CONTROL, RTC, PM1, TEMPMEASURE, DEBUG, SOCKETS, CASC, WALLBOX, CONNX50, STECA (veuillez signaler les unités erronées / manquantes); L'adaptateur calcule désormais les valeurs jour / semaine / mois / année pour: STATISTIC.LIVE_GRID_EXPORT, STATISTIC.LIVE_GRID_IMPORT, STATISTIC.LIVE_HOUSE_CONS, STATISTIC.LIVE_PV_GEN, STATISTIC.LIVE_BAT_CHARGE_MASTER, STATISTIC.LIVE_BAT_CHARGE_MASTER, STATISTIC.LIVE_BAT_CHARGE_MASTER, STATISTIC.LIVE_BAT_CHARGE_MASTER, STATISGE_BISGEMASTER. Les valeurs calculées se trouvent sous le _calc. point de données. Les informations sur les valeurs quotidiennes ont été supprimées de l'API par le SENEC dans le passé. Donc, nous y revoilà ...",
|
|
85
|
-
"it": "(NoBl) Aggiunti datapoint per: PM1OBJ1, PM1OBJ2, EG_CONTROL, RTC, PM1, TEMPMEASURE, DEBUG, SOCKETS, CASC, WALLBOX, CONNX50, STECA (si prega di segnalare unità errate / mancanti) .; L'adattatore ora calcola i valori giorno / settimana / mese / anno per: STATISTIC.LIVE_GRID_EXPORT, STATISTIC.LIVE_GRID_IMPORT, STATISTIC.LIVE_HOUSE_CONS, STATISTIC.LIVE_PV_GEN, STATISTIC.LIVE_BAT_CHARGE_MASTER, STATISTIC.LIVE_BAT_DISCHARGE_MASTER. I valori calcolati possono essere trovati sotto _calc. datapoint. Le informazioni sui valori giornalieri sono state rimosse dall'API da SENEC in passato. Quindi eccoci di nuovo ...",
|
|
86
|
-
"es": "(NoBl) Se agregaron puntos de datos para: PM1OBJ1, PM1OBJ2, EG_CONTROL, RTC, PM1, TEMPMEASURE, DEBUG, SOCKETS, CASC, WALLBOX, CONNX50, STECA (informe las unidades incorrectas / faltantes); El adaptador ahora calcula los valores de día / semana / mes / año para: STATISTIC.LIVE_GRID_EXPORT, STATISTIC.LIVE_GRID_IMPORT, STATISTIC.LIVE_HOUSE_CONS, STATISTIC.LIVE_PV_GEN, STATISTIC.LIVE_BAT_CHARGE_MASTER, STATISTIC.LIVE_BARGE_DISTER, STATISTIC.LIVE_BARGE_DISTER. Los valores calculados se pueden encontrar debajo de _calc. punto de datos. La información sobre los valores diarios fue eliminada de la API por SENEC en el pasado. Aquí vamos de nuevo ...",
|
|
87
|
-
"pl": "(NoBl) Dodano punkty danych dla: PM1OBJ1, PM1OBJ2, EG_CONTROL, RTC, PM1, TEMPMEASURE, DEBUG, SOCKETS, CASC, WALLBOX, CONNX50, STECA (proszę zgłosić błędne / brakujące jednostki) .; Adapter oblicza teraz wartości dzień / tydzień / miesiąc / rok dla: STATISTIC.LIVE_GRID_EXPORT, STATISTIC.LIVE_GRID_IMPORT, STATISTIC.LIVE_HOUSE_CONS, STATISTIC.LIVE_PV_GEN, STATISTIC.LIVE_BAT_CHARGE_MAPORT, STATISTIC.LIVE_HOUSE_CONS, STATISTIC.LIVE_PV_GEN, STATISTIC.LIVE_BAT_CHARGE_MASTER_BATISTIC_STERMADIS. Obliczone wartości można znaleźć poniżej _calc. punkt danych. Informacje o wartościach dziennych zostały w przeszłości usunięte z API przez SENEC. Więc zaczynamy znowu ...",
|
|
88
|
-
"zh-cn": "(NoBl)添加了以下数据点:PM1OBJ1,PM1OBJ2,EG_CONTROL,RTC,PM1,TEMPMEASURE,DEBUG,SOCKETS,CASC,WALLBOX,CONNX50,STECA(请报告错误/丢失的单元)。适配器现在为以下日期计算日/周/月/年值:STATISTIC.LIVE_GRID_EXPORT,STATISTIC.LIVE_GRID_IMPORT,STATISTIC.LIVE_HOUSE_CONS,STATISTIC.LIVE_PV_GEN,STATISTIC.LIVE_BAT_CHARGE_MASTER,STATISTIC.LIVE_BAT_DISCHARGE_MASTER。计算值可以在_calc下面找到。数据点。过去,SENEC已从API中删除了有关每日值的信息。所以我们再来一次..."
|
|
89
89
|
}
|
|
90
90
|
},
|
|
91
91
|
"docs": {
|
|
@@ -132,23 +132,6 @@
|
|
|
132
132
|
"compact": true,
|
|
133
133
|
"materialize": true,
|
|
134
134
|
"materializeTab": false,
|
|
135
|
-
"adminTab": {
|
|
136
|
-
"singleton": true,
|
|
137
|
-
"name": {
|
|
138
|
-
"en": "Senec (JavaScript)",
|
|
139
|
-
"de": "Senec (JavaScript)",
|
|
140
|
-
"ru": "Senec (JavaScript)",
|
|
141
|
-
"pt": "Senec (JavaScript)",
|
|
142
|
-
"nl": "Senec (JavaScript)",
|
|
143
|
-
"fr": "Senec (JavaScript)",
|
|
144
|
-
"it": "Senec (JavaScript)",
|
|
145
|
-
"es": "Senec (JavaScript)",
|
|
146
|
-
"pl": "Senec (JavaScript)",
|
|
147
|
-
"zh-cn": "塞内克 (JavaScript)"
|
|
148
|
-
},
|
|
149
|
-
"link": "",
|
|
150
|
-
"fa-icon": "info"
|
|
151
|
-
},
|
|
152
135
|
"supportCustoms": false,
|
|
153
136
|
"dependencies": [
|
|
154
137
|
{
|
package/lib/state_attr.js
CHANGED
|
@@ -2064,6 +2064,78 @@ const state_attr = {
|
|
|
2064
2064
|
datetype: false,
|
|
2065
2065
|
iptype: false,
|
|
2066
2066
|
multiply: 1
|
|
2067
|
+
},
|
|
2068
|
+
'BMS.CELL_BALANCE_STATUS': {
|
|
2069
|
+
name: 'CELL_BALANCE_STATUS',
|
|
2070
|
+
unit: '',
|
|
2071
|
+
booltype: false,
|
|
2072
|
+
datetype: false,
|
|
2073
|
+
iptype: false,
|
|
2074
|
+
multiply: 1
|
|
2075
|
+
},
|
|
2076
|
+
'BMS.CELL_TEMPERATURES_MODULE_A': {
|
|
2077
|
+
name: 'CELL_TEMPERATURES_MODULE_A',
|
|
2078
|
+
unit: '°C',
|
|
2079
|
+
booltype: false,
|
|
2080
|
+
datetype: false,
|
|
2081
|
+
iptype: false,
|
|
2082
|
+
multiply: 1
|
|
2083
|
+
},
|
|
2084
|
+
'BMS.CELL_TEMPERATURES_MODULE_B': {
|
|
2085
|
+
name: 'CELL_TEMPERATURES_MODULE_B',
|
|
2086
|
+
unit: '°C',
|
|
2087
|
+
booltype: false,
|
|
2088
|
+
datetype: false,
|
|
2089
|
+
iptype: false,
|
|
2090
|
+
multiply: 1
|
|
2091
|
+
},
|
|
2092
|
+
'BMS.CELL_TEMPERATURES_MODULE_C': {
|
|
2093
|
+
name: 'CELL_TEMPERATURES_MODULE_C',
|
|
2094
|
+
unit: '°C',
|
|
2095
|
+
booltype: false,
|
|
2096
|
+
datetype: false,
|
|
2097
|
+
iptype: false,
|
|
2098
|
+
multiply: 1
|
|
2099
|
+
},
|
|
2100
|
+
'BMS.CELL_TEMPERATURES_MODULE_D': {
|
|
2101
|
+
name: 'CELL_TEMPERATURES_MODULE_D',
|
|
2102
|
+
unit: '°C',
|
|
2103
|
+
booltype: false,
|
|
2104
|
+
datetype: false,
|
|
2105
|
+
iptype: false,
|
|
2106
|
+
multiply: 1
|
|
2107
|
+
},
|
|
2108
|
+
'BMS.CELL_VOLTAGES_MODULE_A': {
|
|
2109
|
+
name: 'CELL_VOLTAGES_MODULE_A',
|
|
2110
|
+
unit: 'mV',
|
|
2111
|
+
booltype: false,
|
|
2112
|
+
datetype: false,
|
|
2113
|
+
iptype: false,
|
|
2114
|
+
multiply: 1
|
|
2115
|
+
},
|
|
2116
|
+
'BMS.CELL_VOLTAGES_MODULE_B': {
|
|
2117
|
+
name: 'CELL_VOLTAGES_MODULE_V',
|
|
2118
|
+
unit: 'mV',
|
|
2119
|
+
booltype: false,
|
|
2120
|
+
datetype: false,
|
|
2121
|
+
iptype: false,
|
|
2122
|
+
multiply: 1
|
|
2123
|
+
},
|
|
2124
|
+
'BMS.CELL_VOLTAGES_MODULE_C': {
|
|
2125
|
+
name: 'CELL_VOLTAGES_MODULE_C',
|
|
2126
|
+
unit: 'mV',
|
|
2127
|
+
booltype: false,
|
|
2128
|
+
datetype: false,
|
|
2129
|
+
iptype: false,
|
|
2130
|
+
multiply: 1
|
|
2131
|
+
},
|
|
2132
|
+
'BMS.CELL_VOLTAGES_MODULE_D': {
|
|
2133
|
+
name: 'CELL_VOLTAGES_MODULE_D',
|
|
2134
|
+
unit: 'mV',
|
|
2135
|
+
booltype: false,
|
|
2136
|
+
datetype: false,
|
|
2137
|
+
iptype: false,
|
|
2138
|
+
multiply: 1
|
|
2067
2139
|
},
|
|
2068
2140
|
'BMS.BMS_READY_FLAG': {
|
|
2069
2141
|
name: 'BMS Ready Flag',
|
|
@@ -2353,6 +2425,22 @@ const state_attr = {
|
|
|
2353
2425
|
iptype: false,
|
|
2354
2426
|
multiply: 1
|
|
2355
2427
|
},
|
|
2428
|
+
'BMS.BMS_STATUS': {
|
|
2429
|
+
name: 'BMS Status',
|
|
2430
|
+
unit: '',
|
|
2431
|
+
booltype: true,
|
|
2432
|
+
datetype: false,
|
|
2433
|
+
iptype: false,
|
|
2434
|
+
multiply: 1
|
|
2435
|
+
},
|
|
2436
|
+
'BMS.BMS_STATUS_TIMESTAMP': {
|
|
2437
|
+
name: 'BMS Status Timestamp',
|
|
2438
|
+
unit: '',
|
|
2439
|
+
booltype: true,
|
|
2440
|
+
datetype: false,
|
|
2441
|
+
iptype: false,
|
|
2442
|
+
multiply: 1
|
|
2443
|
+
},
|
|
2356
2444
|
'BMS.STATUS': {
|
|
2357
2445
|
name: 'Status',
|
|
2358
2446
|
unit: '',
|
|
@@ -2993,6 +3081,22 @@ const state_attr = {
|
|
|
2993
3081
|
iptype: false,
|
|
2994
3082
|
multiply: 1
|
|
2995
3083
|
},
|
|
3084
|
+
'ENERGY.GUI_BAT_DATA_MAX_CELL_VOLTAGE': {
|
|
3085
|
+
name: 'BAT_DATA_MAX_CELL_VOLTAGE',
|
|
3086
|
+
unit: 'mV',
|
|
3087
|
+
booltype: false,
|
|
3088
|
+
datetype: false,
|
|
3089
|
+
iptype: false,
|
|
3090
|
+
multiply: 1
|
|
3091
|
+
},
|
|
3092
|
+
'ENERGY.GUI_BAT_DATA_MIN_CELL_VOLTAGE': {
|
|
3093
|
+
name: 'BAT_DATA_MIN_CELL_VOLTAGE',
|
|
3094
|
+
unit: 'mV',
|
|
3095
|
+
booltype: false,
|
|
3096
|
+
datetype: false,
|
|
3097
|
+
iptype: false,
|
|
3098
|
+
multiply: 1
|
|
3099
|
+
},
|
|
2996
3100
|
'ENERGY.GUI_BAT_DATA_OA_CHARGING': {
|
|
2997
3101
|
name: 'BAT_DATA_OA_CHARGING',
|
|
2998
3102
|
unit: 'W',
|
|
@@ -3385,14 +3489,6 @@ const state_attr = {
|
|
|
3385
3489
|
iptype: false,
|
|
3386
3490
|
multiply: 1
|
|
3387
3491
|
},
|
|
3388
|
-
'ENERGY.OFFPEAK_TARGET': {
|
|
3389
|
-
name: 'Offpeak Target',
|
|
3390
|
-
unit: '',
|
|
3391
|
-
booltype: false,
|
|
3392
|
-
datetype: false,
|
|
3393
|
-
iptype: false,
|
|
3394
|
-
multiply: 1
|
|
3395
|
-
},
|
|
3396
3492
|
'ENERGY.OFFPEAK_CURRENT': {
|
|
3397
3493
|
name: 'Offpeak Current',
|
|
3398
3494
|
unit: 'A',
|
|
@@ -3401,9 +3497,9 @@ const state_attr = {
|
|
|
3401
3497
|
iptype: false,
|
|
3402
3498
|
multiply: 1
|
|
3403
3499
|
},
|
|
3404
|
-
'ENERGY.
|
|
3405
|
-
name: 'Offpeak
|
|
3406
|
-
unit: '
|
|
3500
|
+
'ENERGY.OFFPEAK_DURATION': {
|
|
3501
|
+
name: 'Offpeak Duration',
|
|
3502
|
+
unit: '',
|
|
3407
3503
|
booltype: false,
|
|
3408
3504
|
datetype: false,
|
|
3409
3505
|
iptype: false,
|
|
@@ -3417,8 +3513,16 @@ const state_attr = {
|
|
|
3417
3513
|
iptype: false,
|
|
3418
3514
|
multiply: 1
|
|
3419
3515
|
},
|
|
3420
|
-
|
|
3421
|
-
name: 'Offpeak
|
|
3516
|
+
'ENERGY.OFFPEAK_RUNNING': {
|
|
3517
|
+
name: 'Offpeak Running',
|
|
3518
|
+
unit: '',
|
|
3519
|
+
booltype: true,
|
|
3520
|
+
datetype: false,
|
|
3521
|
+
iptype: false,
|
|
3522
|
+
multiply: 1
|
|
3523
|
+
},
|
|
3524
|
+
'ENERGY.OFFPEAK_TARGET': {
|
|
3525
|
+
name: 'Offpeak Target',
|
|
3422
3526
|
unit: '',
|
|
3423
3527
|
booltype: false,
|
|
3424
3528
|
datetype: false,
|
|
@@ -3537,6 +3641,14 @@ const state_attr = {
|
|
|
3537
3641
|
iptype: false,
|
|
3538
3642
|
multiply: 1
|
|
3539
3643
|
},
|
|
3644
|
+
'ENERGY.SUPP_BATT_DIAG': {
|
|
3645
|
+
name: 'SUPP_BATT_DIAG',
|
|
3646
|
+
unit: '',
|
|
3647
|
+
booltype: true,
|
|
3648
|
+
datetype: false,
|
|
3649
|
+
iptype: false,
|
|
3650
|
+
multiply: 1
|
|
3651
|
+
},
|
|
3540
3652
|
'ENERGY.TEST_CHARGE_CHRG_START': {
|
|
3541
3653
|
name: 'TEST_CHARGE_CHRG_START',
|
|
3542
3654
|
unit: '',
|
package/lib/state_trans.js
CHANGED
|
@@ -91,7 +91,13 @@ const state_trans = {
|
|
|
91
91
|
88: 'NETZBETREIBER: ENTLADEN GESPERRT (88)',
|
|
92
92
|
89: 'RESERVEKAPAZITÄT (89)',
|
|
93
93
|
90: 'SELBSTTEST FEHLER (90)',
|
|
94
|
-
91: 'ISOLATIONSFEHLER (91)'
|
|
94
|
+
91: 'ISOLATIONSFEHLER (91)',
|
|
95
|
+
92: 'PV-MODUS (92)',
|
|
96
|
+
93: 'FERNABSCHALTUNG NETZBETREIBER (93)',
|
|
97
|
+
94: 'FEHLER DRM0 (94)',
|
|
98
|
+
95: 'BATTERIEDIAGNOSE (95)',
|
|
99
|
+
96: 'BATTERIE BALANCIERUNG (96)',
|
|
100
|
+
97: 'SICHERHEITSENTLADUNG (97)'
|
|
95
101
|
},
|
|
96
102
|
'ENERGY_STAT_STATE.1': {
|
|
97
103
|
0: 'INITIALSTATE',
|
|
@@ -185,7 +191,13 @@ const state_trans = {
|
|
|
185
191
|
88: 'GRID OPERATOR: DISCHARGE PROHIBITED',
|
|
186
192
|
89: 'SPARE CAPACITY',
|
|
187
193
|
90: 'SELFTEST ERROR',
|
|
188
|
-
91: 'EARTH FAULT'
|
|
194
|
+
91: 'EARTH FAULT',
|
|
195
|
+
92: 'PV-MODE',
|
|
196
|
+
93: 'REMOTE SHUTDOWN GRID OPERATOR',
|
|
197
|
+
94: 'ERROR DRM0 (94)',
|
|
198
|
+
95: 'BATTERY DIAGNOSIS (95)',
|
|
199
|
+
96: 'BATTERY BALANCING (96)',
|
|
200
|
+
97: 'SAFETY DISCHARGE (97)'
|
|
189
201
|
},
|
|
190
202
|
'ENERGY_STAT_STATE.2': {
|
|
191
203
|
0: 'STATO INIZIALE',
|
|
@@ -279,7 +291,13 @@ const state_trans = {
|
|
|
279
291
|
88: 'OPERATORE DI RETE: SCARICA BLOCCATA',
|
|
280
292
|
89: 'CAPACITA INUTILIZZATA',
|
|
281
293
|
90: 'ERRORE DI AUTOTEST',
|
|
282
|
-
91: 'FAGLIA TERRESTRE'
|
|
294
|
+
91: 'FAGLIA TERRESTRE',
|
|
295
|
+
92: 'MODALITÀ FOTOVOLTAICA',
|
|
296
|
+
93: 'SPEGNIMENTO A DISTANZA OPERATORE DI RETE',
|
|
297
|
+
94: 'ERRORE DRM0',
|
|
298
|
+
95: 'DIAGNOSI DELLA BATTERIA (95)',
|
|
299
|
+
96: 'BILANCIAMENTO DELLA BATTERIA (96)',
|
|
300
|
+
97: 'SCARICO DI SICUREZZA (97)'
|
|
283
301
|
},
|
|
284
302
|
'FACTORY.BAT_TYPE.0' : {
|
|
285
303
|
0: 'Studer Xtender (0)',
|
|
@@ -478,7 +496,13 @@ const state_trans = {
|
|
|
478
496
|
88: 'NETZBETREIBER: ENTLADEN GESPERRT (88)',
|
|
479
497
|
89: 'RESERVEKAPAZITÄT (89)',
|
|
480
498
|
90: 'SELBSTTEST FEHLER (90)',
|
|
481
|
-
91: 'ISOLATIONSFEHLER (91)'
|
|
499
|
+
91: 'ISOLATIONSFEHLER (91)',
|
|
500
|
+
92: 'PV-MODUS (92)',
|
|
501
|
+
93: 'FERNABSCHALTUNG NETZBETREIBER (93)',
|
|
502
|
+
94: 'FEHLER DRM0 (94)',
|
|
503
|
+
95: 'BATTERIEDIAGNOSE (95)',
|
|
504
|
+
96: 'BATTERIE BALANCIERUNG (96)',
|
|
505
|
+
97: 'SICHERHEITSENTLADUNG (97)'
|
|
482
506
|
},
|
|
483
507
|
'STATISTIC.CURRENT_STATE.1': {
|
|
484
508
|
0: 'INITIALSTATE',
|
|
@@ -572,7 +596,13 @@ const state_trans = {
|
|
|
572
596
|
88: 'GRID OPERATOR: DISCHARGE PROHIBITED',
|
|
573
597
|
89: 'SPARE CAPACITY',
|
|
574
598
|
90: 'SELFTEST ERROR',
|
|
575
|
-
91: 'EARTH FAULT'
|
|
599
|
+
91: 'EARTH FAULT',
|
|
600
|
+
92: 'PV-MODE',
|
|
601
|
+
93: 'REMOTE SHUTDOWN GRID OPERATOR',
|
|
602
|
+
94: 'ERROR DRM0',
|
|
603
|
+
95: 'BATTERY DIAGNOSIS',
|
|
604
|
+
96: 'BATTERY BALANCING',
|
|
605
|
+
97: 'SAFETY DISCHARGE'
|
|
576
606
|
},
|
|
577
607
|
'STATISTIC.CURRENT_STATE.2': {
|
|
578
608
|
0: 'STATO INIZIALE',
|
|
@@ -666,7 +696,13 @@ const state_trans = {
|
|
|
666
696
|
88: 'OPERATORE DI RETE: SCARICA BLOCCATA',
|
|
667
697
|
89: 'CAPACITA INUTILIZZATA',
|
|
668
698
|
90: 'ERRORE DI AUTOTEST',
|
|
669
|
-
91: 'FAGLIA TERRESTRE'
|
|
699
|
+
91: 'FAGLIA TERRESTRE',
|
|
700
|
+
92: 'MODALITÀ FOTOVOLTAICA',
|
|
701
|
+
93: 'SPEGNIMENTO A DISTANZA OPERATORE DI RETE',
|
|
702
|
+
94: 'ERRORE DRM0',
|
|
703
|
+
95: 'DIAGNOSI DELLA BATTERIA',
|
|
704
|
+
96: 'BILANCIAMENTO DELLA BATTERIA',
|
|
705
|
+
97: 'SCARICO DI SICUREZZA'
|
|
670
706
|
},
|
|
671
707
|
'WALLBOX.STATE.0' : {
|
|
672
708
|
161: 'Warte auf E-Fahrzeug (161)',
|
package/main.js
CHANGED
|
@@ -165,7 +165,8 @@ class Senec extends utils.Adapter {
|
|
|
165
165
|
|
|
166
166
|
const url = 'http://' + this.config.senecip + '/lala.cgi';
|
|
167
167
|
var form = '{';
|
|
168
|
-
|
|
168
|
+
form += '"BMS":{"CELL_TEMPERATURES_MODULE_A":"","CELL_TEMPERATURES_MODULE_B":"","CELL_TEMPERATURES_MODULE_C":"","CELL_TEMPERATURES_MODULE_D":"","CELL_VOLTAGES_MODULE_A":"","CELL_VOLTAGES_MODULE_B":"","CELL_VOLTAGES_MODULE_C":"","CELL_VOLTAGES_MODULE_D":"","CURRENT":"","SOC":"","SYSTEM_SOC":"","TEMP_MAX":"","TEMP_MIN":"","VOLTAGE":""}';
|
|
169
|
+
form += ',"ENERGY":{"STAT_STATE":"","GUI_BAT_DATA_POWER":"","GUI_INVERTER_POWER":"","GUI_HOUSE_POW":"","GUI_GRID_POW":"","GUI_BAT_DATA_FUEL_CHARGE":"","GUI_CHARGING_INFO":"","GUI_BOOSTING_INFO":"","GUI_BAT_DATA_POWER":"","GUI_BAT_DATA_VOLTAGE":"","GUI_BAT_DATA_CURRENT":"","GUI_BAT_DATA_FUEL_CHARGE":"","GUI_BAT_DATA_OA_CHARGING":"","STAT_LIMITED_NET_SKEW":""}';
|
|
169
170
|
form += ',"PV1":{"POWER_RATIO":"","MPP_POWER":""}';
|
|
170
171
|
form += ',"PWR_UNIT":{"POWER_L1":"","POWER_L2":"","POWER_L3":""}';
|
|
171
172
|
form += ',"PM1OBJ1":{"FREQ":"","U_AC":"","I_AC":"","P_AC":"","P_TOTAL":""}';
|
|
@@ -392,7 +393,7 @@ class Senec extends utils.Adapter {
|
|
|
392
393
|
if (valRef < valCur) {
|
|
393
394
|
await this.doState(key + refValue, valCur, descRef, unitRef, true);
|
|
394
395
|
} else {
|
|
395
|
-
this.log.
|
|
396
|
+
this.log.warn("(Calc) Not updating reference value for: " + name.substring(10) + "! Old RefValue (" + valRef + ") >= new RefValue (" + valCur + "). Impossible situation. If this is intentional, please update via admin!");
|
|
396
397
|
}
|
|
397
398
|
} else {
|
|
398
399
|
this.log.silly("(Calc) Updating " + day +" value for: " + name.substring(10) + ": " + Number((valCur - valRef).toFixed(2)));
|
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "iobroker.senec",
|
|
3
|
-
"version": "1.3.
|
|
3
|
+
"version": "1.3.8",
|
|
4
4
|
"description": "Senec Home",
|
|
5
5
|
"author": {
|
|
6
6
|
"name": "NoBl",
|
|
@@ -24,29 +24,28 @@
|
|
|
24
24
|
"url": "https://github.com/nobl/ioBroker.senec.git"
|
|
25
25
|
},
|
|
26
26
|
"dependencies": {
|
|
27
|
-
"axios": "^0.
|
|
28
|
-
"@iobroker/adapter-core": "^2.
|
|
27
|
+
"axios": "^0.27.2",
|
|
28
|
+
"@iobroker/adapter-core": "^2.6.0"
|
|
29
29
|
},
|
|
30
30
|
"devDependencies": {
|
|
31
|
-
"@alcalzone/release-script": "^3.5.
|
|
32
|
-
|
|
33
|
-
"@
|
|
34
|
-
"@types/chai
|
|
35
|
-
"@types/
|
|
36
|
-
"@types/mocha": "^9.
|
|
37
|
-
"@types/node": "^17.0.
|
|
31
|
+
"@alcalzone/release-script": "^3.5.9",
|
|
32
|
+
"@iobroker/adapter-dev": "^1.0.0",
|
|
33
|
+
"@iobroker/testing": "^3.0.2",
|
|
34
|
+
"@types/chai": "^4.3.1",
|
|
35
|
+
"@types/chai-as-promised": "^7.1.5",
|
|
36
|
+
"@types/mocha": "^9.1.1",
|
|
37
|
+
"@types/node": "^17.0.38",
|
|
38
38
|
"@types/proxyquire": "^1.3.28",
|
|
39
|
-
"@types/sinon": "^10.0.
|
|
39
|
+
"@types/sinon": "^10.0.11",
|
|
40
40
|
"@types/sinon-chai": "^3.2.8",
|
|
41
41
|
"chai": "^4.3.6",
|
|
42
42
|
"chai-as-promised": "^7.1.1",
|
|
43
|
-
"eslint": "^8.
|
|
44
|
-
"
|
|
45
|
-
"mocha": "^9.1.3",
|
|
43
|
+
"eslint": "^8.16.0",
|
|
44
|
+
"mocha": "^10.0.0",
|
|
46
45
|
"proxyquire": "^2.1.3",
|
|
47
|
-
"sinon": "^
|
|
46
|
+
"sinon": "^14.0.0",
|
|
48
47
|
"sinon-chai": "^3.7.0",
|
|
49
|
-
"typescript": "~4.
|
|
48
|
+
"typescript": "~4.7.2"
|
|
50
49
|
},
|
|
51
50
|
"main": "main.js",
|
|
52
51
|
"files": [
|
|
@@ -60,13 +59,14 @@
|
|
|
60
59
|
],
|
|
61
60
|
"scripts": {
|
|
62
61
|
"test:js": "mocha --config test/mocharc.custom.json \"{!(node_modules|test)/**/*.test.js,*.test.js,test/**/test!(PackageFiles|Startup).js}\"",
|
|
63
|
-
|
|
64
|
-
|
|
65
|
-
|
|
66
|
-
|
|
67
|
-
|
|
68
|
-
|
|
69
|
-
|
|
62
|
+
"test:package": "mocha test/package --exit",
|
|
63
|
+
"test:unit": "mocha test/unit --exit",
|
|
64
|
+
"test:integration": "mocha test/integration --exit",
|
|
65
|
+
"test": "npm run test:js && npm run test:package",
|
|
66
|
+
"check": "tsc --noEmit -p tsconfig.check.json",
|
|
67
|
+
"lint": "eslint",
|
|
68
|
+
"translate": "translate-adapter",
|
|
69
|
+
"release": "release-script"
|
|
70
70
|
},
|
|
71
71
|
"bugs": {
|
|
72
72
|
"url": "https://github.com/nobl/ioBroker.senec/issues"
|