iobroker.nexowatt-ui 0.8.78 → 0.8.79
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/ems/modules/storage-control.js +27 -19
- package/io-package.json +5 -5
- package/main.js +36 -11
- package/package.json +3 -2
- package/www/manifest.webmanifest +2 -2
- package/www/sw.js +2 -2
|
@@ -2,7 +2,7 @@
|
|
|
2
2
|
* AUTO-GENERATED RUNTIME FILE - NICHT MANUELL BEARBEITEN.
|
|
3
3
|
*
|
|
4
4
|
* Quelle: src-ts/runtime-executables/ems/modules/storage-control.ts
|
|
5
|
-
* Quell-Hash: sha256:
|
|
5
|
+
* Quell-Hash: sha256:be276c78afd9b41451793405bafb264900c9d4652653fa584eed0990c6b1d4c3
|
|
6
6
|
* Erzeugung: npm run sync:ts-runtime-executables
|
|
7
7
|
*
|
|
8
8
|
* Zweck:
|
|
@@ -1675,16 +1675,25 @@ if (typeof soc === 'number') {
|
|
|
1675
1675
|
: ((typeof battW === 'number') ? (battW + errAdjW) : (curSetW + errAdjW));
|
|
1676
1676
|
|
|
1677
1677
|
// Safety-Clamp gegen unnötige Export-Spikes:
|
|
1678
|
-
// Begrenze
|
|
1679
|
-
//
|
|
1680
|
-
//
|
|
1678
|
+
// Begrenze die Entladung auf die plausibel aktuelle Last am NVP.
|
|
1679
|
+
// WICHTIGER Feldfix 0.8.79: Der letzte Sollwert darf hier NICHT als
|
|
1680
|
+
// aktuelle Entladung/Demand-Basis zählen. Wenn ein Speicher träge reagiert
|
|
1681
|
+
// oder die Istleistung nicht vertrauenswürdig ist, würde der Integrator
|
|
1682
|
+
// sonst immer weiter hochlaufen (z. B. 2,6 kW Netzbezug -> 71,6 kW
|
|
1683
|
+
// Entladevorgabe). Als Demand zählen nur echte Messwerte plus eine
|
|
1684
|
+
// separate Lastschätzung aus dem Energiefluss.
|
|
1681
1685
|
const importRawNowW = Math.max(0, (typeof nvpRawW === 'number') ? nvpRawW : 0);
|
|
1682
1686
|
const measuredDischargeNowW = (typeof battW === 'number') ? Math.max(0, battW) : 0;
|
|
1683
|
-
const
|
|
1684
|
-
const
|
|
1687
|
+
const loadEstimate = getFeneconAcLoadTargetW();
|
|
1688
|
+
const loadEstimateW = (loadEstimate && Number.isFinite(Number(loadEstimate.w))) ? Math.max(0, Number(loadEstimate.w)) : 0;
|
|
1685
1689
|
const safetyMarginW = 200;
|
|
1686
|
-
const
|
|
1690
|
+
const demandBaseW = Math.max(importRawNowW + measuredDischargeNowW, loadEstimateW);
|
|
1691
|
+
const maxByDemandW = demandBaseW + safetyMarginW;
|
|
1687
1692
|
if (Number.isFinite(maxByDemandW) && maxByDemandW > 0) {
|
|
1693
|
+
dischargeDemandHardCapW = (typeof dischargeDemandHardCapW === 'number')
|
|
1694
|
+
? Math.min(dischargeDemandHardCapW, maxByDemandW)
|
|
1695
|
+
: maxByDemandW;
|
|
1696
|
+
dischargeDemandHardCapReason = `Tarif-NVP-Demand-Cap (${String(loadEstimate && loadEstimate.source ? loadEstimate.source : 'live-nvp')})`;
|
|
1688
1697
|
nextSetW = Math.min(nextSetW, maxByDemandW);
|
|
1689
1698
|
}
|
|
1690
1699
|
|
|
@@ -1853,25 +1862,24 @@ if (targetW === 0 && selfDischargeEnabled) {
|
|
|
1853
1862
|
|
|
1854
1863
|
// Safety-Clamp gegen Überschwingen:
|
|
1855
1864
|
// Wenn battW nicht gemappt ist (oder NVP kurzfristig "alt" ist), kann die inkrementelle Regelung
|
|
1856
|
-
// zu großen Sollwerten aufintegrieren. Wir begrenzen deshalb die Entladeleistung
|
|
1857
|
-
//
|
|
1858
|
-
//
|
|
1859
|
-
//
|
|
1860
|
-
//
|
|
1865
|
+
// zu großen Sollwerten aufintegrieren. Wir begrenzen deshalb die Entladeleistung auf die
|
|
1866
|
+
// plausibel aktuelle Last: echter NVP-Import + echte Batterie-Ist-Entladung bzw. eine
|
|
1867
|
+
// separate Lastschätzung aus dem Energiefluss.
|
|
1868
|
+
// WICHTIGER Feldfix 0.8.79: Der letzte eigene Sollwert darf hier NICHT als Demand-Basis
|
|
1869
|
+
// verwendet werden. Genau diese Rückkopplung hat aus einem kleinen Netzbezug eine
|
|
1870
|
+
// viel zu hohe Entladevorgabe aufintegriert.
|
|
1861
1871
|
const importRawNowW = Math.max(0, (typeof nvpRawW === 'number') ? nvpRawW : 0);
|
|
1862
1872
|
const measuredDischargeNowW = (typeof battW === 'number') ? Math.max(0, battW) : 0;
|
|
1863
|
-
|
|
1864
|
-
|
|
1865
|
-
// Der letzte eigene Sollwert zählt deshalb als plausible aktuelle Entladebasis.
|
|
1866
|
-
const commandedDischargeNowW = curSetW > 0 ? curSetW : 0;
|
|
1867
|
-
const dischargeNowW = Math.max(measuredDischargeNowW, commandedDischargeNowW);
|
|
1873
|
+
const loadEstimate = getFeneconAcLoadTargetW();
|
|
1874
|
+
const loadEstimateW = (loadEstimate && Number.isFinite(Number(loadEstimate.w))) ? Math.max(0, Number(loadEstimate.w)) : 0;
|
|
1868
1875
|
const safetyMarginW = 200; // bewusst konservativ; Feintuning über selfTargetGridW/Deadband/Rampe
|
|
1869
|
-
const
|
|
1876
|
+
const demandBaseW = Math.max(importRawNowW + measuredDischargeNowW, loadEstimateW);
|
|
1877
|
+
const maxByDemandW = demandBaseW + safetyMarginW;
|
|
1870
1878
|
if (Number.isFinite(maxByDemandW) && maxByDemandW >= 0) {
|
|
1871
1879
|
dischargeDemandHardCapW = (typeof dischargeDemandHardCapW === 'number')
|
|
1872
1880
|
? Math.min(dischargeDemandHardCapW, maxByDemandW)
|
|
1873
1881
|
: maxByDemandW;
|
|
1874
|
-
dischargeDemandHardCapReason =
|
|
1882
|
+
dischargeDemandHardCapReason = `Eigenverbrauch-NVP-Demand-Cap (${String(loadEstimate && loadEstimate.source ? loadEstimate.source : 'live-nvp')})`;
|
|
1875
1883
|
nextSetW = Math.min(nextSetW, maxByDemandW);
|
|
1876
1884
|
}
|
|
1877
1885
|
|
package/io-package.json
CHANGED
|
@@ -1,8 +1,12 @@
|
|
|
1
1
|
{
|
|
2
2
|
"common": {
|
|
3
3
|
"name": "nexowatt-ui",
|
|
4
|
-
"version": "0.8.
|
|
4
|
+
"version": "0.8.79",
|
|
5
5
|
"news": {
|
|
6
|
+
"0.8.79": {
|
|
7
|
+
"de": "Version 0.8.79: Härtet die Speicher-Entladeregelung gegen Sollwert-Rückkopplung. Der letzte Entlade-Sollwert wird nicht mehr als echte Ist-Entladung für den NVP-Demand-Cap genutzt; Tarif- und Eigenverbrauchsmodus werden nach der Rampe hart auf die plausible Last begrenzt. Speicherfarm-Istleistungs-DPs, die auf Steuer-/Setpoint-DPs zeigen, werden ignoriert und diagnostiziert.",
|
|
8
|
+
"en": "Version 0.8.79: Hardens storage discharge control against setpoint feedback. The last discharge setpoint is no longer used as real measured discharge for the NVP demand cap; tariff and self-consumption modes are hard-capped after ramping to plausible load. Storage-farm feedback power datapoints that point to control/setpoint datapoints are ignored and diagnosed."
|
|
9
|
+
},
|
|
6
10
|
"0.8.78": {
|
|
7
11
|
"de": "Version 0.8.78: Korrigiert die Speicher-App-Trennung. Speicherregelung steuert wieder die normale Eigenverbrauchsoptimierung, MultiUse greift nur aktiv als SoC-Zonen-Policy, Speicherfarm verteilt nur Sollwerte und 0-W-Farm-Limits sperren wieder bewusst die jeweilige Richtung.",
|
|
8
12
|
"en": "Version 0.8.78: Fixes storage app separation. Storage control again handles normal self-consumption optimization, MultiUse only applies as an active SoC-zone policy, the storage farm only distributes setpoints, and 0-W farm limits intentionally block the respective direction again."
|
|
@@ -26,10 +30,6 @@
|
|
|
26
30
|
"0.8.73": {
|
|
27
31
|
"de": "Version 0.8.73: EVCS-Kacheln flackern beim Hover nicht mehr. Hover bleibt auf der Ladepunktseite neutral; grüne Umrandung/Leuchten erscheint nur bei echter aktiver Ladung.",
|
|
28
32
|
"en": "Version 0.8.73: EVCS tiles no longer flicker on hover. Hover remains neutral on the chargepoint page; green border/glow is shown only for real active charging."
|
|
29
|
-
},
|
|
30
|
-
"0.8.72": {
|
|
31
|
-
"de": "Version 0.8.72: App-Center-Heizstab-Eingaben stabilisiert. Stufenwerte lösen beim Tippen keinen vollständigen Rebuild mehr aus; notwendige Strukturänderungen erhalten Scrollposition und Fokus.",
|
|
32
|
-
"en": "Version 0.8.72: Stabilizes App Center heating-rod inputs. Stage values no longer trigger a full rebuild while typing; required structural updates preserve scroll position and focus."
|
|
33
33
|
}
|
|
34
34
|
},
|
|
35
35
|
"title": "NexoWatt UI",
|
package/main.js
CHANGED
|
@@ -2,7 +2,7 @@
|
|
|
2
2
|
* AUTO-GENERATED RUNTIME FILE - NICHT MANUELL BEARBEITEN.
|
|
3
3
|
*
|
|
4
4
|
* Quelle: src-ts/runtime-executables/main.ts
|
|
5
|
-
* Quell-Hash: sha256:
|
|
5
|
+
* Quell-Hash: sha256:c32b1dda975f0939d878e55a7847427345f9ff4cb214c4210c2409ad1b725881
|
|
6
6
|
* Erzeugung: npm run sync:ts-runtime-executables
|
|
7
7
|
*
|
|
8
8
|
* Zweck:
|
|
@@ -5343,6 +5343,31 @@ class NexoWattVis extends utils.Adapter {
|
|
|
5343
5343
|
const hasDischargeSetpoint = !!(setSignedPowerId || setDischargePowerId);
|
|
5344
5344
|
const hasAnySetpoint = !!(setSignedPowerId || setChargePowerId || setDischargePowerId);
|
|
5345
5345
|
|
|
5346
|
+
// Feldschutz 0.8.79: Ist-Leistungs-DPs der Speicherfarm dürfen niemals
|
|
5347
|
+
// auf Steuer-/Sollwert-DPs zeigen. Sonst liest die Farm ihre eigene
|
|
5348
|
+
// dischargePowerW-/powerSetpointW-Vorgabe als echte Entladung zurück;
|
|
5349
|
+
// die NVP-Regelung sieht dann eine künstlich hohe Batterie-Istleistung
|
|
5350
|
+
// und kann bis zu absurden Sollwerten hochintegrieren.
|
|
5351
|
+
const targetPowerIds = [setSignedPowerId, setChargePowerId, setDischargePowerId].filter(Boolean);
|
|
5352
|
+
const looksLikeSetpointPowerId = (id) => {
|
|
5353
|
+
const sid = String(id || '').trim();
|
|
5354
|
+
if (!sid) return false;
|
|
5355
|
+
const lower = sid.toLowerCase();
|
|
5356
|
+
return targetPowerIds.includes(sid) ||
|
|
5357
|
+
lower.includes('.aliases.ctrl.') ||
|
|
5358
|
+
lower.includes('.ctrl.') ||
|
|
5359
|
+
lower.includes('powersetpoint') ||
|
|
5360
|
+
lower.includes('setpoint');
|
|
5361
|
+
};
|
|
5362
|
+
const signedFeedbackUsable = !!signedId && !looksLikeSetpointPowerId(signedId);
|
|
5363
|
+
const chargeFeedbackUsable = !!chgId && !looksLikeSetpointPowerId(chgId);
|
|
5364
|
+
const dischargeFeedbackUsable = !!dchgId && !looksLikeSetpointPowerId(dchgId);
|
|
5365
|
+
const ignoredPowerFeedback = [];
|
|
5366
|
+
if (signedId && !signedFeedbackUsable) ignoredPowerFeedback.push('signedPowerId wirkt wie Sollwert-DP');
|
|
5367
|
+
if (chgId && !chargeFeedbackUsable) ignoredPowerFeedback.push('chargePowerId wirkt wie Sollwert-DP');
|
|
5368
|
+
if (dchgId && !dischargeFeedbackUsable) ignoredPowerFeedback.push('dischargePowerId wirkt wie Sollwert-DP');
|
|
5369
|
+
if (ignoredPowerFeedback.length) status.powerFeedbackIgnoredReason = ignoredPowerFeedback.join('; ');
|
|
5370
|
+
|
|
5346
5371
|
// Ab v0.6.258 sind die Leistungsgrenzen bewusst feste Eingaben in der Farm-Konfiguration.
|
|
5347
5372
|
// Dynamische Max-Leistungs-DPs werden in der harten Dispatch-Logik nicht mehr verwendet,
|
|
5348
5373
|
// damit die Speicherfarm auch mit einfachen Signed-DP-Systemen herstellerneutral läuft.
|
|
@@ -5384,9 +5409,9 @@ class NexoWattVis extends utils.Adapter {
|
|
|
5384
5409
|
};
|
|
5385
5410
|
|
|
5386
5411
|
addBases(socId);
|
|
5387
|
-
addBases(signedId);
|
|
5388
|
-
addBases(chgId);
|
|
5389
|
-
addBases(dchgId);
|
|
5412
|
+
if (signedFeedbackUsable) addBases(signedId);
|
|
5413
|
+
if (chargeFeedbackUsable) addBases(chgId);
|
|
5414
|
+
if (dischargeFeedbackUsable) addBases(dchgId);
|
|
5390
5415
|
addBases(pvId);
|
|
5391
5416
|
addBases(availableId);
|
|
5392
5417
|
addBases(faultId);
|
|
@@ -5460,9 +5485,9 @@ class NexoWattVis extends utils.Adapter {
|
|
|
5460
5485
|
considerTs(stConn);
|
|
5461
5486
|
considerTs(stOff);
|
|
5462
5487
|
considerTs(stErr);
|
|
5463
|
-
if (
|
|
5464
|
-
if (
|
|
5465
|
-
if (
|
|
5488
|
+
if (signedFeedbackUsable) considerTs(await getState(signedId));
|
|
5489
|
+
if (chargeFeedbackUsable) considerTs(await getState(chgId));
|
|
5490
|
+
if (dischargeFeedbackUsable) considerTs(await getState(dchgId));
|
|
5466
5491
|
if (pvId) considerTs(await getState(pvId));
|
|
5467
5492
|
if (availableId) considerTs(await getState(availableId));
|
|
5468
5493
|
if (faultId) considerTs(await getState(faultId));
|
|
@@ -5476,7 +5501,7 @@ class NexoWattVis extends utils.Adapter {
|
|
|
5476
5501
|
// Do we have any feedback values configured/available?
|
|
5477
5502
|
// Setpoint-DPs alone are enough for dispatch, but they are not treated as real feedback.
|
|
5478
5503
|
let hasFeedbackValue = false;
|
|
5479
|
-
for (const id of [signedId, chgId, dchgId, pvId, socId, availableId, faultId, chargeAllowedId, dischargeAllowedId]) {
|
|
5504
|
+
for (const id of [signedFeedbackUsable ? signedId : '', chargeFeedbackUsable ? chgId : '', dischargeFeedbackUsable ? dchgId : '', pvId, socId, availableId, faultId, chargeAllowedId, dischargeAllowedId]) {
|
|
5480
5505
|
if (!id) continue;
|
|
5481
5506
|
const st = await getState(id);
|
|
5482
5507
|
if (st && st.val !== undefined && st.val !== null) { hasFeedbackValue = true; break; }
|
|
@@ -5718,7 +5743,7 @@ class NexoWattVis extends utils.Adapter {
|
|
|
5718
5743
|
|
|
5719
5744
|
let usedSigned = false;
|
|
5720
5745
|
|
|
5721
|
-
if (
|
|
5746
|
+
if (signedFeedbackUsable) {
|
|
5722
5747
|
const v = await readNumber(signedId, 'power', { allowStale: true });
|
|
5723
5748
|
if (Number.isFinite(v)) {
|
|
5724
5749
|
let vv = invSigned ? -v : v;
|
|
@@ -5738,7 +5763,7 @@ class NexoWattVis extends utils.Adapter {
|
|
|
5738
5763
|
}
|
|
5739
5764
|
|
|
5740
5765
|
// Fallback: getrennte Messwerte
|
|
5741
|
-
if (!usedSigned &&
|
|
5766
|
+
if (!usedSigned && chargeFeedbackUsable) {
|
|
5742
5767
|
const v = await readNumber(chgId, 'power', { allowStale: true });
|
|
5743
5768
|
if (Number.isFinite(v)) {
|
|
5744
5769
|
let vv = invChg ? -v : v;
|
|
@@ -5749,7 +5774,7 @@ class NexoWattVis extends utils.Adapter {
|
|
|
5749
5774
|
}
|
|
5750
5775
|
}
|
|
5751
5776
|
|
|
5752
|
-
if (!usedSigned &&
|
|
5777
|
+
if (!usedSigned && dischargeFeedbackUsable) {
|
|
5753
5778
|
const v = await readNumber(dchgId, 'power', { allowStale: true });
|
|
5754
5779
|
if (Number.isFinite(v)) {
|
|
5755
5780
|
let vv = invDchg ? -v : v;
|
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "iobroker.nexowatt-ui",
|
|
3
|
-
"version": "0.8.
|
|
3
|
+
"version": "0.8.79",
|
|
4
4
|
"description": "Responsive NexoWatt EMS visualization adapter.",
|
|
5
5
|
"author": "NexoWatt",
|
|
6
6
|
"license": "UNLICENSED",
|
|
@@ -283,7 +283,8 @@
|
|
|
283
283
|
"test:evcs-online-id-depth": "node scripts/verify-evcs-online-id-depth.js",
|
|
284
284
|
"test:evcs-tile-hover": "node scripts/verify-evcs-tile-hover.js",
|
|
285
285
|
"test:evcs-hover-state": "node scripts/verify-evcs-hover-state.js",
|
|
286
|
-
"test:storage-control-app-separation": "node scripts/verify-storage-control-app-separation.js"
|
|
286
|
+
"test:storage-control-app-separation": "node scripts/verify-storage-control-app-separation.js",
|
|
287
|
+
"test:storage-discharge-demand-cap": "node scripts/verify-storage-discharge-demand-cap.js"
|
|
287
288
|
},
|
|
288
289
|
"dependencies": {
|
|
289
290
|
"@iobroker/adapter-core": "^3.4.1",
|
package/www/manifest.webmanifest
CHANGED
package/www/sw.js
CHANGED
|
@@ -2,7 +2,7 @@
|
|
|
2
2
|
* AUTO-GENERATED RUNTIME FILE - NICHT MANUELL BEARBEITEN.
|
|
3
3
|
*
|
|
4
4
|
* Quelle: src-ts/runtime-executables/www/sw.ts
|
|
5
|
-
* Quell-Hash: sha256:
|
|
5
|
+
* Quell-Hash: sha256:40ebdde7a8bfe7113fe1f0cb37a0eb1a8f1dcc5311ed7a2d67e4ac1e959ff7d7
|
|
6
6
|
* Erzeugung: npm run sync:ts-runtime-executables
|
|
7
7
|
*
|
|
8
8
|
* Zweck:
|
|
@@ -42,7 +42,7 @@
|
|
|
42
42
|
|
|
43
43
|
// Increment cache name on releases so browser updates JS/HTML reliably.
|
|
44
44
|
// NOTE: Keep this monotonic to force SW updates on hotfixes.
|
|
45
|
-
const CACHE_NAME = 'nexowatt-cache-
|
|
45
|
+
const CACHE_NAME = 'nexowatt-cache-v380';
|
|
46
46
|
|
|
47
47
|
const OFFLINE_URLS = [
|
|
48
48
|
'./',
|