iobroker.nexowatt-ui 0.8.78 → 0.8.79

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -2,7 +2,7 @@
2
2
  * AUTO-GENERATED RUNTIME FILE - NICHT MANUELL BEARBEITEN.
3
3
  *
4
4
  * Quelle: src-ts/runtime-executables/ems/modules/storage-control.ts
5
- * Quell-Hash: sha256:4d2234db2a1c6d62fe65d90a3934f90c4e63de05764335f660e735b93542b93d
5
+ * Quell-Hash: sha256:be276c78afd9b41451793405bafb264900c9d4652653fa584eed0990c6b1d4c3
6
6
  * Erzeugung: npm run sync:ts-runtime-executables
7
7
  *
8
8
  * Zweck:
@@ -1675,16 +1675,25 @@ if (typeof soc === 'number') {
1675
1675
  : ((typeof battW === 'number') ? (battW + errAdjW) : (curSetW + errAdjW));
1676
1676
 
1677
1677
  // Safety-Clamp gegen unnötige Export-Spikes:
1678
- // Begrenze grob auf aktuelle Hauslast am NVP: Import (roh) + aktuelle Entladung (falls messbar) + Puffer.
1679
- // Bei aktiver Regelung zählt der letzte selbst gesetzte Sollwert als plausible Entladebasis,
1680
- // damit zeitversetzte/0-W-Istwerte die Farm nicht künstlich herunterziehen.
1678
+ // Begrenze die Entladung auf die plausibel aktuelle Last am NVP.
1679
+ // WICHTIGER Feldfix 0.8.79: Der letzte Sollwert darf hier NICHT als
1680
+ // aktuelle Entladung/Demand-Basis zählen. Wenn ein Speicher träge reagiert
1681
+ // oder die Istleistung nicht vertrauenswürdig ist, würde der Integrator
1682
+ // sonst immer weiter hochlaufen (z. B. 2,6 kW Netzbezug -> 71,6 kW
1683
+ // Entladevorgabe). Als Demand zählen nur echte Messwerte plus eine
1684
+ // separate Lastschätzung aus dem Energiefluss.
1681
1685
  const importRawNowW = Math.max(0, (typeof nvpRawW === 'number') ? nvpRawW : 0);
1682
1686
  const measuredDischargeNowW = (typeof battW === 'number') ? Math.max(0, battW) : 0;
1683
- const commandedDischargeNowW = curSetW > 0 ? curSetW : 0;
1684
- const dischargeNowW = Math.max(measuredDischargeNowW, commandedDischargeNowW);
1687
+ const loadEstimate = getFeneconAcLoadTargetW();
1688
+ const loadEstimateW = (loadEstimate && Number.isFinite(Number(loadEstimate.w))) ? Math.max(0, Number(loadEstimate.w)) : 0;
1685
1689
  const safetyMarginW = 200;
1686
- const maxByDemandW = importRawNowW + dischargeNowW + safetyMarginW;
1690
+ const demandBaseW = Math.max(importRawNowW + measuredDischargeNowW, loadEstimateW);
1691
+ const maxByDemandW = demandBaseW + safetyMarginW;
1687
1692
  if (Number.isFinite(maxByDemandW) && maxByDemandW > 0) {
1693
+ dischargeDemandHardCapW = (typeof dischargeDemandHardCapW === 'number')
1694
+ ? Math.min(dischargeDemandHardCapW, maxByDemandW)
1695
+ : maxByDemandW;
1696
+ dischargeDemandHardCapReason = `Tarif-NVP-Demand-Cap (${String(loadEstimate && loadEstimate.source ? loadEstimate.source : 'live-nvp')})`;
1688
1697
  nextSetW = Math.min(nextSetW, maxByDemandW);
1689
1698
  }
1690
1699
 
@@ -1853,25 +1862,24 @@ if (targetW === 0 && selfDischargeEnabled) {
1853
1862
 
1854
1863
  // Safety-Clamp gegen Überschwingen:
1855
1864
  // Wenn battW nicht gemappt ist (oder NVP kurzfristig "alt" ist), kann die inkrementelle Regelung
1856
- // zu großen Sollwerten aufintegrieren. Wir begrenzen deshalb die Entladeleistung grob auf
1857
- // "aktuelle Last" am NVP: Import (roh) + aktuelle Entladung (falls messbar) + kleiner Puffer.
1858
- // Dadurch bleibt die Regelung im Bereich der realen Hauslast und erzeugt keine Export-Spikes.
1859
- // Bei aktiver Eigenverbrauchsregelung zählt der letzte selbst gesetzte Sollwert als plausible
1860
- // Entladebasis, damit zeitversetzte/0-W-Istwerte die Farm nicht künstlich herunterziehen.
1865
+ // zu großen Sollwerten aufintegrieren. Wir begrenzen deshalb die Entladeleistung auf die
1866
+ // plausibel aktuelle Last: echter NVP-Import + echte Batterie-Ist-Entladung bzw. eine
1867
+ // separate Lastschätzung aus dem Energiefluss.
1868
+ // WICHTIGER Feldfix 0.8.79: Der letzte eigene Sollwert darf hier NICHT als Demand-Basis
1869
+ // verwendet werden. Genau diese Rückkopplung hat aus einem kleinen Netzbezug eine
1870
+ // viel zu hohe Entladevorgabe aufintegriert.
1861
1871
  const importRawNowW = Math.max(0, (typeof nvpRawW === 'number') ? nvpRawW : 0);
1862
1872
  const measuredDischargeNowW = (typeof battW === 'number') ? Math.max(0, battW) : 0;
1863
- // Wenn Farm-/Gateway-Istwerte 0 W oder zeitversetzt liefern, darf der Demand-Cap
1864
- // die laufende Eigenverbrauchs-Entladung nicht künstlich auf Import+Puffer drücken.
1865
- // Der letzte eigene Sollwert zählt deshalb als plausible aktuelle Entladebasis.
1866
- const commandedDischargeNowW = curSetW > 0 ? curSetW : 0;
1867
- const dischargeNowW = Math.max(measuredDischargeNowW, commandedDischargeNowW);
1873
+ const loadEstimate = getFeneconAcLoadTargetW();
1874
+ const loadEstimateW = (loadEstimate && Number.isFinite(Number(loadEstimate.w))) ? Math.max(0, Number(loadEstimate.w)) : 0;
1868
1875
  const safetyMarginW = 200; // bewusst konservativ; Feintuning über selfTargetGridW/Deadband/Rampe
1869
- const maxByDemandW = importRawNowW + dischargeNowW + safetyMarginW;
1876
+ const demandBaseW = Math.max(importRawNowW + measuredDischargeNowW, loadEstimateW);
1877
+ const maxByDemandW = demandBaseW + safetyMarginW;
1870
1878
  if (Number.isFinite(maxByDemandW) && maxByDemandW >= 0) {
1871
1879
  dischargeDemandHardCapW = (typeof dischargeDemandHardCapW === 'number')
1872
1880
  ? Math.min(dischargeDemandHardCapW, maxByDemandW)
1873
1881
  : maxByDemandW;
1874
- dischargeDemandHardCapReason = 'Eigenverbrauch-NVP-Demand-Cap';
1882
+ dischargeDemandHardCapReason = `Eigenverbrauch-NVP-Demand-Cap (${String(loadEstimate && loadEstimate.source ? loadEstimate.source : 'live-nvp')})`;
1875
1883
  nextSetW = Math.min(nextSetW, maxByDemandW);
1876
1884
  }
1877
1885
 
package/io-package.json CHANGED
@@ -1,8 +1,12 @@
1
1
  {
2
2
  "common": {
3
3
  "name": "nexowatt-ui",
4
- "version": "0.8.78",
4
+ "version": "0.8.79",
5
5
  "news": {
6
+ "0.8.79": {
7
+ "de": "Version 0.8.79: Härtet die Speicher-Entladeregelung gegen Sollwert-Rückkopplung. Der letzte Entlade-Sollwert wird nicht mehr als echte Ist-Entladung für den NVP-Demand-Cap genutzt; Tarif- und Eigenverbrauchsmodus werden nach der Rampe hart auf die plausible Last begrenzt. Speicherfarm-Istleistungs-DPs, die auf Steuer-/Setpoint-DPs zeigen, werden ignoriert und diagnostiziert.",
8
+ "en": "Version 0.8.79: Hardens storage discharge control against setpoint feedback. The last discharge setpoint is no longer used as real measured discharge for the NVP demand cap; tariff and self-consumption modes are hard-capped after ramping to plausible load. Storage-farm feedback power datapoints that point to control/setpoint datapoints are ignored and diagnosed."
9
+ },
6
10
  "0.8.78": {
7
11
  "de": "Version 0.8.78: Korrigiert die Speicher-App-Trennung. Speicherregelung steuert wieder die normale Eigenverbrauchsoptimierung, MultiUse greift nur aktiv als SoC-Zonen-Policy, Speicherfarm verteilt nur Sollwerte und 0-W-Farm-Limits sperren wieder bewusst die jeweilige Richtung.",
8
12
  "en": "Version 0.8.78: Fixes storage app separation. Storage control again handles normal self-consumption optimization, MultiUse only applies as an active SoC-zone policy, the storage farm only distributes setpoints, and 0-W farm limits intentionally block the respective direction again."
@@ -26,10 +30,6 @@
26
30
  "0.8.73": {
27
31
  "de": "Version 0.8.73: EVCS-Kacheln flackern beim Hover nicht mehr. Hover bleibt auf der Ladepunktseite neutral; grüne Umrandung/Leuchten erscheint nur bei echter aktiver Ladung.",
28
32
  "en": "Version 0.8.73: EVCS tiles no longer flicker on hover. Hover remains neutral on the chargepoint page; green border/glow is shown only for real active charging."
29
- },
30
- "0.8.72": {
31
- "de": "Version 0.8.72: App-Center-Heizstab-Eingaben stabilisiert. Stufenwerte lösen beim Tippen keinen vollständigen Rebuild mehr aus; notwendige Strukturänderungen erhalten Scrollposition und Fokus.",
32
- "en": "Version 0.8.72: Stabilizes App Center heating-rod inputs. Stage values no longer trigger a full rebuild while typing; required structural updates preserve scroll position and focus."
33
33
  }
34
34
  },
35
35
  "title": "NexoWatt UI",
package/main.js CHANGED
@@ -2,7 +2,7 @@
2
2
  * AUTO-GENERATED RUNTIME FILE - NICHT MANUELL BEARBEITEN.
3
3
  *
4
4
  * Quelle: src-ts/runtime-executables/main.ts
5
- * Quell-Hash: sha256:6aa512c54a159430a7268d42c8806a1ca2b711cb2cf17ec845f4406a730b04aa
5
+ * Quell-Hash: sha256:c32b1dda975f0939d878e55a7847427345f9ff4cb214c4210c2409ad1b725881
6
6
  * Erzeugung: npm run sync:ts-runtime-executables
7
7
  *
8
8
  * Zweck:
@@ -5343,6 +5343,31 @@ class NexoWattVis extends utils.Adapter {
5343
5343
  const hasDischargeSetpoint = !!(setSignedPowerId || setDischargePowerId);
5344
5344
  const hasAnySetpoint = !!(setSignedPowerId || setChargePowerId || setDischargePowerId);
5345
5345
 
5346
+ // Feldschutz 0.8.79: Ist-Leistungs-DPs der Speicherfarm dürfen niemals
5347
+ // auf Steuer-/Sollwert-DPs zeigen. Sonst liest die Farm ihre eigene
5348
+ // dischargePowerW-/powerSetpointW-Vorgabe als echte Entladung zurück;
5349
+ // die NVP-Regelung sieht dann eine künstlich hohe Batterie-Istleistung
5350
+ // und kann bis zu absurden Sollwerten hochintegrieren.
5351
+ const targetPowerIds = [setSignedPowerId, setChargePowerId, setDischargePowerId].filter(Boolean);
5352
+ const looksLikeSetpointPowerId = (id) => {
5353
+ const sid = String(id || '').trim();
5354
+ if (!sid) return false;
5355
+ const lower = sid.toLowerCase();
5356
+ return targetPowerIds.includes(sid) ||
5357
+ lower.includes('.aliases.ctrl.') ||
5358
+ lower.includes('.ctrl.') ||
5359
+ lower.includes('powersetpoint') ||
5360
+ lower.includes('setpoint');
5361
+ };
5362
+ const signedFeedbackUsable = !!signedId && !looksLikeSetpointPowerId(signedId);
5363
+ const chargeFeedbackUsable = !!chgId && !looksLikeSetpointPowerId(chgId);
5364
+ const dischargeFeedbackUsable = !!dchgId && !looksLikeSetpointPowerId(dchgId);
5365
+ const ignoredPowerFeedback = [];
5366
+ if (signedId && !signedFeedbackUsable) ignoredPowerFeedback.push('signedPowerId wirkt wie Sollwert-DP');
5367
+ if (chgId && !chargeFeedbackUsable) ignoredPowerFeedback.push('chargePowerId wirkt wie Sollwert-DP');
5368
+ if (dchgId && !dischargeFeedbackUsable) ignoredPowerFeedback.push('dischargePowerId wirkt wie Sollwert-DP');
5369
+ if (ignoredPowerFeedback.length) status.powerFeedbackIgnoredReason = ignoredPowerFeedback.join('; ');
5370
+
5346
5371
  // Ab v0.6.258 sind die Leistungsgrenzen bewusst feste Eingaben in der Farm-Konfiguration.
5347
5372
  // Dynamische Max-Leistungs-DPs werden in der harten Dispatch-Logik nicht mehr verwendet,
5348
5373
  // damit die Speicherfarm auch mit einfachen Signed-DP-Systemen herstellerneutral läuft.
@@ -5384,9 +5409,9 @@ class NexoWattVis extends utils.Adapter {
5384
5409
  };
5385
5410
 
5386
5411
  addBases(socId);
5387
- addBases(signedId);
5388
- addBases(chgId);
5389
- addBases(dchgId);
5412
+ if (signedFeedbackUsable) addBases(signedId);
5413
+ if (chargeFeedbackUsable) addBases(chgId);
5414
+ if (dischargeFeedbackUsable) addBases(dchgId);
5390
5415
  addBases(pvId);
5391
5416
  addBases(availableId);
5392
5417
  addBases(faultId);
@@ -5460,9 +5485,9 @@ class NexoWattVis extends utils.Adapter {
5460
5485
  considerTs(stConn);
5461
5486
  considerTs(stOff);
5462
5487
  considerTs(stErr);
5463
- if (signedId) considerTs(await getState(signedId));
5464
- if (chgId) considerTs(await getState(chgId));
5465
- if (dchgId) considerTs(await getState(dchgId));
5488
+ if (signedFeedbackUsable) considerTs(await getState(signedId));
5489
+ if (chargeFeedbackUsable) considerTs(await getState(chgId));
5490
+ if (dischargeFeedbackUsable) considerTs(await getState(dchgId));
5466
5491
  if (pvId) considerTs(await getState(pvId));
5467
5492
  if (availableId) considerTs(await getState(availableId));
5468
5493
  if (faultId) considerTs(await getState(faultId));
@@ -5476,7 +5501,7 @@ class NexoWattVis extends utils.Adapter {
5476
5501
  // Do we have any feedback values configured/available?
5477
5502
  // Setpoint-DPs alone are enough for dispatch, but they are not treated as real feedback.
5478
5503
  let hasFeedbackValue = false;
5479
- for (const id of [signedId, chgId, dchgId, pvId, socId, availableId, faultId, chargeAllowedId, dischargeAllowedId]) {
5504
+ for (const id of [signedFeedbackUsable ? signedId : '', chargeFeedbackUsable ? chgId : '', dischargeFeedbackUsable ? dchgId : '', pvId, socId, availableId, faultId, chargeAllowedId, dischargeAllowedId]) {
5480
5505
  if (!id) continue;
5481
5506
  const st = await getState(id);
5482
5507
  if (st && st.val !== undefined && st.val !== null) { hasFeedbackValue = true; break; }
@@ -5718,7 +5743,7 @@ class NexoWattVis extends utils.Adapter {
5718
5743
 
5719
5744
  let usedSigned = false;
5720
5745
 
5721
- if (signedId) {
5746
+ if (signedFeedbackUsable) {
5722
5747
  const v = await readNumber(signedId, 'power', { allowStale: true });
5723
5748
  if (Number.isFinite(v)) {
5724
5749
  let vv = invSigned ? -v : v;
@@ -5738,7 +5763,7 @@ class NexoWattVis extends utils.Adapter {
5738
5763
  }
5739
5764
 
5740
5765
  // Fallback: getrennte Messwerte
5741
- if (!usedSigned && chgId) {
5766
+ if (!usedSigned && chargeFeedbackUsable) {
5742
5767
  const v = await readNumber(chgId, 'power', { allowStale: true });
5743
5768
  if (Number.isFinite(v)) {
5744
5769
  let vv = invChg ? -v : v;
@@ -5749,7 +5774,7 @@ class NexoWattVis extends utils.Adapter {
5749
5774
  }
5750
5775
  }
5751
5776
 
5752
- if (!usedSigned && dchgId) {
5777
+ if (!usedSigned && dischargeFeedbackUsable) {
5753
5778
  const v = await readNumber(dchgId, 'power', { allowStale: true });
5754
5779
  if (Number.isFinite(v)) {
5755
5780
  let vv = invDchg ? -v : v;
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "iobroker.nexowatt-ui",
3
- "version": "0.8.78",
3
+ "version": "0.8.79",
4
4
  "description": "Responsive NexoWatt EMS visualization adapter.",
5
5
  "author": "NexoWatt",
6
6
  "license": "UNLICENSED",
@@ -283,7 +283,8 @@
283
283
  "test:evcs-online-id-depth": "node scripts/verify-evcs-online-id-depth.js",
284
284
  "test:evcs-tile-hover": "node scripts/verify-evcs-tile-hover.js",
285
285
  "test:evcs-hover-state": "node scripts/verify-evcs-hover-state.js",
286
- "test:storage-control-app-separation": "node scripts/verify-storage-control-app-separation.js"
286
+ "test:storage-control-app-separation": "node scripts/verify-storage-control-app-separation.js",
287
+ "test:storage-discharge-demand-cap": "node scripts/verify-storage-discharge-demand-cap.js"
287
288
  },
288
289
  "dependencies": {
289
290
  "@iobroker/adapter-core": "^3.4.1",
@@ -44,6 +44,6 @@
44
44
  "purpose": "maskable"
45
45
  }
46
46
  ],
47
- "version": "0.8.78",
48
- "appVersion": "0.8.78"
47
+ "version": "0.8.79",
48
+ "appVersion": "0.8.79"
49
49
  }
package/www/sw.js CHANGED
@@ -2,7 +2,7 @@
2
2
  * AUTO-GENERATED RUNTIME FILE - NICHT MANUELL BEARBEITEN.
3
3
  *
4
4
  * Quelle: src-ts/runtime-executables/www/sw.ts
5
- * Quell-Hash: sha256:450c858958cff245c1b3d728b5ff1b52f959e52c53adab637eca05db8532e30f
5
+ * Quell-Hash: sha256:40ebdde7a8bfe7113fe1f0cb37a0eb1a8f1dcc5311ed7a2d67e4ac1e959ff7d7
6
6
  * Erzeugung: npm run sync:ts-runtime-executables
7
7
  *
8
8
  * Zweck:
@@ -42,7 +42,7 @@
42
42
 
43
43
  // Increment cache name on releases so browser updates JS/HTML reliably.
44
44
  // NOTE: Keep this monotonic to force SW updates on hotfixes.
45
- const CACHE_NAME = 'nexowatt-cache-v379';
45
+ const CACHE_NAME = 'nexowatt-cache-v380';
46
46
 
47
47
  const OFFLINE_URLS = [
48
48
  './',