iobroker.luxtronik2-controller 1.0.3 → 1.1.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/README.md +16 -8
- package/build/actionHandlers.js +14 -6
- package/build/actionHandlers.js.map +2 -2
- package/build/main.js +305 -82
- package/build/main.js.map +2 -2
- package/build/mapping/settings.js +2 -2
- package/build/mapping/settings.js.map +1 -1
- package/build/modbusManager.js +32 -4
- package/build/modbusManager.js.map +3 -3
- package/build/pvManager.js +55 -26
- package/build/pvManager.js.map +2 -2
- package/build/types.js.map +1 -1
- package/build/virtualStates.js +6 -6
- package/build/virtualStates.js.map +2 -2
- package/io-package.json +27 -27
- package/package.json +1 -1
package/io-package.json
CHANGED
|
@@ -1,8 +1,34 @@
|
|
|
1
1
|
{
|
|
2
2
|
"common": {
|
|
3
3
|
"name": "luxtronik2-controller",
|
|
4
|
-
"version": "1.0
|
|
4
|
+
"version": "1.1.0",
|
|
5
5
|
"news": {
|
|
6
|
+
"1.1.0": {
|
|
7
|
+
"en": "Replaced static `35 °C` / `+10.0 K` jump in cycle optimization (`CycleOpt-PreHeat` / `CycleOpt-AfterWW`) and forced heating (`Zwangsheizen`) with a dynamic, hysteresis-based relative offset (`base offset + hysteresis + 0.5 K`) via `heating_temperature` (volatile SHI `10002` / native Param `1`) to prevent screed overshoot and short-cycling in well-insulated homes\nAdded heating release checks (`P0003` / `C0125`) and hot water lock-time schedule checks (`P0004` / `C0124` / `P405..P505`, including midnight wrap-around and 25-minute pre-heat lookahead) to cycle optimization\nImproved `Heizen_nach_Wasser` reset handling (3-minute spike guard instead of 10 minutes once return target is reached), immediate pre-heat offset reset on WW start, and automatic cleanup of stale `CycleOpt-PreHeat` offsets in idle without affecting manual `Zwangsheizen`\nAdded automatic restoration of temporary hot water target increases (`forceSoll` & `Zwangswarmwasser`) after WW completion even when `idle_defaults_aktiv` is disabled\nEliminated PV boost flip-flop writes during idle and cycle transitions by delegating directly to `evaluatePvBoost` without intermediate resets to baseline\nFixed raw fallback indices in `calculateTotalEnergy()` to read `rawParams[1136]/[1137]` (factor `0.01`) instead of `rawValues[156]/[157]` and added 2-decimal rounding",
|
|
8
|
+
"de": "Statischen Sprung bei der Zyklusoptimierung (`CycleOPT-Preheat`/`CycleOPT-AfterWW`) und `Zwangsbeheizen` durch einen dynamischen, hysteresebasierten Relativversatz (`base offset + hysteresis + 0,5 K`) über `heating_temperature` (volatile SHI `10002`/nativer Param `1`) ersetzt, um zu verhindern Estrichüberhöhung und Kurzschluss in gut gedämmten Häusern\nZur Zyklusoptimierung wurden Heizungsfreigabeprüfungen (`P0003`/`C0125`) und Warmwasserschleuse (`P0004`/`C0124`/`P405.. P505`, einschließlich Mitternacht und 25-minütiger Vorwärmvorlauf) hinzugefügt\nVerbessertes „Heizen_nach_Wasser“ -Reset (3-minütiger Spike-Guard statt 10 Minuten nach Erreichen des Ziels), sofortiger Reset bei WW-Start und automatische Bereinigung abgestandener `CycleOPT-Preheat`-Offsets im Leerlauf, ohne manuelle `Zwangsheizen` zu beeinflussen\nAutomatische Wiederherstellung temporärer Warmwasser-Zielerhöhungen (`forceSoll` & `Zwangswarmwasser`) nach WW-Ende hinzugefügt, auch wenn `idle_defaults_aktiv` deaktiviert ist\nPV-Boost-Flip-Flop-Writes bei Leerlauf- und Zykluswechseln durch direkte Delegierung an `EvaluatePvBoost` ohne Resets zur Ausgangslinie\nRohindizes in `calculateTotalEnergy () `wurden auf `rawParams [1136]/[1137]` (Faktor `0,01`) statt `rawValues [156]/[157] `korrigiert und 2-Dezimal-Rundung hinzugefügt",
|
|
9
|
+
"ru": "Статический скачок при оптимизации цикла («Cycleopt-Preheat»/«+10,0 K») и принудительный нагрев («Zwangsheizen») заменен динамическим относительным смещением, основанным на гистерезисе («смещение основания + гистерезис + 0,5 K») с помощью «температуры нагрева» (изменчивое значение SHI `10002`/собственный параметр `1`) для предотвращения перегрева стяжки и короткого замыкания в хорошо изолированных домах\nДля оптимизации цикла добавлены проверки спуска тепла (`P0003`/`C0125`) и проверки графика блокировки горячей воды (`P0004`/`C0124`/`P405`, включая полночь и 25-минутный предварительный нагрев)\nУлучшенная обработка перезагрузки `heizen_nach_wasser` (3-минутная защита от спайков вместо 10 минут после достижения цели возврата), немедленный сброс смещения предварительного нагрева при запуске WW и автоматическая очистка устаревших смещений «Cycleopt-Preheat» на холостом ходу без влияния на режим «Zwangsheizen» вручную\nДобавлено автоматическое восстановление временных целевых значений по горячей воде (`Forcesoll` и `Zwangswarmwasser`) после завершения WW, даже если `idle_defaults_aktiv` отключен\nУстранена возможность записи на триггере PV Boost во время простоя и циклических переходов за счет прямого делегирования функции `EvaluatePVBoost` без промежуточных переходов к базовому уровню\nИсправлены необработанные резервные индексы в `calculateTotalEnergy () `, которые читали `rawParams [1136]/[1137]` (коэффициент 0,01) вместо `rawValues [156]/[157] `и добавлено округление на 2 десятичных дроби",
|
|
10
|
+
"pt": "Substituiu o salto estático de `35 °C`/`+10,0 K` na otimização do ciclo (`Cycleopt-preheat`/`Cycleopt-afterWW`) por um deslocamento relativo dinâmico baseado em histerese (`base offset + histerese + 0,5 K`) via `heating_temperature` (volátil SHI `10002`) `/native Param `1`) para evitar quedas e ciclos curtos em casas bem isoladas\nForam adicionadas verificações de liberação de aquecimento (`P0003`/`C0125`) e cronograma de bloqueio de água quente (`P0004`/`C0124`/`P405.. P505`, incluindo meia-noite e pré-aquecimento de 25 minutos) à otimização do ciclo\nMelhor reinicialização de `Heizen_nach_wasser` (proteção contra picos de 3 minutos em vez de 10 minutos após atingir a meta de retorno), reinicialização imediata no início da WW e limpeza automática de offsets obsoletos de `Cycleopt-Preheat` em modo inativo sem afetar o manual `Zwangsheizen`\nFoi adicionada a restauração automática de metas temporárias de água quente (`ForceSoll` e `Zwangswarmwasser`) após a WW, mesmo com `idle_defaults_aktiv` desativado\nEliminou as gravações de flip-flop durante transições inativas e cíclicas ao delegar diretamente a `evaluatePVBoost` sem redefinições intermediárias\nCorrigidos índices brutos em `calculateTotalEnergy () `para ler `rawParams [1136]/[1137]` (fator `0,01`) em vez de `rawValues [156]/[157] `e arredondamento de 2 decimais",
|
|
11
|
+
"nl": "Statische sprong van `35°C`/`+10,0 K` in de cyclusoptimalisatie (`CycleOpt-Preheat`/`CycleOpt-afterWW`) en geforceerde verwarming (`Zwangsheizen`) vervangen door een dynamische, op hysterese gebaseerde relatieve offset (`base offset + hysteresis + 0.5 K`) via `heating_temperature` (vluchtige SHI `10002`/native Param `1`) naar voorkom overlopen van de dekvloer en kortsluiting in goed geïsoleerde huizen\nControles voor de verwarming toegevoegd (`P0003`/`C0125`) en controles van het vergrendelingsschema voor warm water (`P0004`/`C0124`/`P405.. P505`, inclusief middernacht en een vooruitblik van 25 minuten voor de voorverwarming) om de cyclus te optimaliseren\nVerbeterde reset van de `Heizen_Nach_Wasser` (spike-guard van 3 minuten in plaats van 10 minuten nadat het retourdoel is bereikt), onmiddellijke reset van de offset voor de voorverwarming bij het starten van de WW, en automatische opschoning van oude `CycleOpt-Preheat` offsets bij stationair gebruik, zonder dat dit gevolgen heeft voor de handmatige `Zwangsheizen`\nAutomatisch herstel toegevoegd van tijdelijke verhogingen van de doelen voor warm water (`ForceSoll` & `Zwangswarmwasser`) na voltooiing van de WW, zelfs als `idle_defaults_aktiv` is uitgeschakeld\nElimineerde flip-flop-schrijfbewerkingen met PV-boost tijdens stationair toerental en cyclusovergangen door rechtstreeks naar `EvaluatePVBoost` te delegeren zonder tussentijdse resets naar de basislijn\nRuwe terugvalindexen opgelost in `CalculateTotalEnergy () `om `RawParams [1136]/[1137]` te lezen (factor `0,01 `) in plaats van `RawValues [156]/[157]` en een afronding met twee decimalen toegevoegd",
|
|
12
|
+
"fr": "Remplacement du saut statique « 35 °C »/« +10,0 K » lors de l'optimisation des cycles (« CycleOpt-Preheat »/« CycleOpt-AfterWW») et du chauffage forcé (« Zwangsheizen ») par un décalage relatif dynamique basé sur l'hystérésis (« décalage de base + hystérésis + 0,5 K ») via « heating_temperature » (SHI volatil « 10002 »/paramètre natif « 1 ») pour éviter de dépasser la chape et de court-circuiter les maisons bien isolées\nAjout de contrôles du déclenchement du chauffage (`P0003`/`C0125`) et de l'heure de verrouillage de l'eau chaude (`P0004`/`C0124`/`P405.. P505`, y compris minuit et 25 minutes de préchauffage) pour optimiser le cycle\nGestion améliorée de la réinitialisation de « Heizen_Nach_Wasser » (protection contre les pointes de 3 minutes au lieu de 10 minutes une fois l'objectif de retour atteint), réinitialisation immédiate du décalage de préchauffage au démarrage de WW et nettoyage automatique des décalages « CycleOpt-Preheat » périmés au ralenti sans affecter le mode manuel\nAjout du rétablissement automatique des objectifs d'eau chaude temporaires (« ForceSoll » et « Zwangswarmwasser ») à la fin de la Seconde Guerre mondiale, même si « idle_defaults_aktiv » est désactivé\nLes écritures PV Boost ont été éliminées pendant les transitions d'inactivité et de cycle en déléguant directement à « EvaluatePVBoost » sans réinitialisation intermédiaire\nCorrection d'indices de repli bruts dans « CalculateTotalEnergy () » comme « RawParams [1136]/[1137] » (facteur « 0,01 ») au lieu de « RawValues [156]/[157] » et a été arrondi à 2 décimales",
|
|
13
|
+
"it": "Sostituita l'ottimizzazione statica del ciclo `35 °C`/`+10,0 K` (`CycleOpt-Preheat`/`CycleOpt-afterWW`) e forzata (`Zwangsheizen`) con un offset relativo dinamico basato sull'isteresi (`offset base + isteresi + 0,5 K`) tramite `heating_temperature` (volatile SHI `10002`/nativo di Param `1`) per evitare massetti e cicli brevi in case ben isolate\nAggiunti i controlli del rilascio del calore (`P0003`/`C0125`) e del tempo di blocco dell'acqua calda (`P0004`/`C0124`/`P405.. P505`, inclusi mezzanotte e preriscaldamento di 25 minuti) per l'ottimizzazione del ciclo\nMigliore gestione del reset di `Heizen_nach_wasser` (protezione spike guard di 3 minuti anziché 10 minuti dopo il ritorno), reset immediato dell'offset di preriscaldamento all'avvio di WW e pulizia automatica degli offset `CycleOpt-Preheat` obsoleti senza influire sul manuale `Zwangsheizen`\nAggiunto il ripristino automatico degli aumenti temporanei di acqua calda (`ForceSoll` e `Zwangswarmwasser`) al termine del WW anche se `idle_defaults_aktiv è disabilitato\nHa eliminato le scritture flip-flop PV Boost durante le transizioni di inattività e ciclo delegando direttamente a `EvaluatePVBoost` senza reset intermedi\nHa corretto gli indici di riserva grezzi in `calculateTotalEnergy () `per leggere `rawParams [1136]/[1137]` (fattore `0,01`) invece di `RawValues [156]/[157] `e ha aggiunto 2 decimali",
|
|
14
|
+
"es": "Sustituyó la optimización estática del salto en el ciclo (`Cycleopt-Precalent`/`Cycleopt-AfterWW`) y el calentamiento forzado (`Zwangsheizen`) por un desfase relativo dinámico basado en la histéresis (`compensación base+ histéresis + 0,5 K) por `heating_temperatura` (volátil SHI `10002` /parámetro nativo `1`) para evitar que la solera se sobrepase y se acorte en casas bien aisladas\nSe han añadido comprobaciones de liberación de calefacción (`P0003`/`C0125`) y comprobaciones del horario de bloqueo del agua caliente (`P0004`/`C0124`/`P405.. P505`, incluidas medianoche y 25 minutos de precalentamiento anticipadas) a la optimización del ciclo\nSe mejoró el manejo del reinicio de Heizen_nach_wasser (3 minutos de protección contra picos en lugar de 10 minutos una vez alcanzado el objetivo de devolución), se restablece inmediatamente al iniciar la Guerra Mundial y se limpian automáticamente las compensaciones obsoletas de «Cycleopt-preheat» en ralentí sin afectar al `Zwangsheizen` manual\nSe ha añadido la restauración automática de los aumentos temporales del objetivo de agua caliente (ForceSoll y Zwangswarmwasser) al terminar la Guerra Mundial, incluso con «idle_defaults_aktiv`\nEliminó las escrituras invertidas de PV Boost durante las transiciones de inactividad y ciclo al delegar directamente en «EvaluatePVBoost» sin restablecimientos intermedios a la línea base\nSe corrigieron los índices alternativos sin procesar en `CalculateTotalEnergy () `para leer `RawParams [1136]/[1137]` (factor 0,01) en lugar de `RawValues [156]/[157] `y se añadió el redondeo con 2 decimales",
|
|
15
|
+
"pl": "Zastąpiony statyczny skok `35 °C`/`+10,0 K` w optymalizacji cyklu (`Cycleopt-Preheat `/`Cycleopt-AfterWW`) i wymuszonym ogrzewaniu (`Zwangsheizen`) dynamicznym, opartym na histerezie przesunięciem względnym (`przesunięcie bazowe+histereza + 0,5 K`) poprzez `temperatura_ogrzewania` (lotny natywny SHI `10002`/Param ``1), aby zapobiec przewyższaniu jastrychu i krótkim cyklom w dobrze ocieplonych domach\nDodano kontrole uwalniania ogrzewania (`P0003`/`C0125`) i kontrole harmonogramu blokady ciepłej wody (`P0004`/`C0124`/`P405.. P505`, w tym podgrzewanie o północy i 25-minutowe podgrzewanie wstępne) w celu optymalizacji cyklu\nUlepszona obsługa resetowania „Heizen_Nach_Wasser” (3-minutowa osłona kolców zamiast 10 minut po osiągnięciu celu powrotu), natychmiastowy reset przesunięcia wstępnego nagrzewania przy starcie WW i automatyczne czyszczenie nieaktualnych przesunięć „CycleOpt-Preheat” na biegu jałowym bez wpływu na ręczne „Zwangsheizen”\nDodano automatyczne przywracanie tymczasowych wzrostów docelowych ciepłej wody (`ForceSoll' & `Zwangswarmwasser`) po zakończeniu wojny światowej, nawet gdy `idle_defaults_aktiv` jest wyłączone\nWyeliminowano zapisy flip-flop PV boost podczas przejścia na biegu jałowym i cyklu poprzez delegowanie bezpośrednio do `EvaluatePVBoost` bez pośrednich resetów do linii bazowej\nNaprawiono nieprzetworzone indeksy rezerwowe w `CalculateTotalEnergy () `, aby odczytać `RawParams [1136]/[1137]` (współczynnik `0,01`) zamiast `rawValues [156]/[157] `i dodano zaokrąglanie 2-dziesiętne",
|
|
16
|
+
"uk": "Замінено статичний стрибок `35 °C`/`+10,0 K` в оптимізації циклу (`Cycleopt-PreHeat`/`Cycleopt-AfterWW`) та примусовий нагрів (`Zwangsheizen`) з динамічним відносним зміщенням на основі гістерезису (`базовий зсув + гістерезис+ 0, 5 К`) через `температура_опалення` (летючий SHI `10002`/native Param `1`) на запобігання переливу стяжки та короткого циклу в добре утеплених будинках\nДля оптимізації циклу додані перевірки випуску опалення (`P0003`/`C0125`) та перевірки графіка блокування гарячої води (`P0004`/`C0124`/`P405.. P505`, включаючи опівнічне обгортання та 25-хвилинний перегляд попереднього нагрівання)\nПокращено обробку скидання `Heizen_nach_wasser` (3-хвилинний захист від спайків замість 10 хвилин після досягнення мети повернення), негайне скидання зсуву попереднього нагрівання при запуску WW та автоматичне очищення застарілих зсувів `Cycleopt-preheat` на холостому ходу, не впливаючи на ручне `Zwangsheizen`\nДодано автоматичне відновлення тимчасового збільшення цілі гарячої води (`ForceSoll` & `Zwangswarmwasser`) після завершення світової війни, навіть якщо `idle_defaults_aktiv` вимкнено\nУсунено записи фліп-шльопанів PV boost під час простою та переходу циклу шляхом делегування безпосередньо до `evaluatePVBoost` без проміжних скидань до базової лінії\nВиправлені необроблені запасні індекси в `calculateTotalEnergy () `для читання `RawParams [1136]/[1137]` (коефіцієнт `0,01`) замість `RaWValues [156]/[157] `та додано 2-десяткове округлення",
|
|
17
|
+
"zh-cn": "通过 `heating_temperure'(易失性 SHI `10002` /原生参数 `1`)将静态的 `35 °C`/ `+10.0 K` 跳跃循环优化(`cycleopt-AfterWW`)和强制加热(`Zwangsheizen`)替换为基于迟滞的动态相对偏移(`基本偏移量+滞后+ 0.5 K`)防止在隔热良好的房屋中出现熨平板过冲和短时间循环\n为循环优化添加了供暖释放检查(`P0003`/`C0125`)和热水锁定时间表检查(`P0004`/`C0124`/`P405.. P505`,包括午夜回转和预热时间表25分钟)\n改进了 “Heizen_nach_Wasser” 重置处理(3 分钟尖刺保护,而不是达到返回目标后的 10 分钟),WW 启动时立即重置预热偏移量,在不影响手动 “Zwangsheizen” 的情况下自动清理空闲状态下陈旧的 “Cycleopt-Preheat” 偏移量\n添加了在 WW 完成后自动恢复临时热水目标增量(`forceSoll` 和 `Zwangswarmwasser`),即使禁用 `idle_defaults_aktiv` 也是如此\n通过直接委托给 “EvaluatePVBoost”,无需中间重置到基线,从而消除了空闲和周期过渡期间的 PV boost 触发器写入\n修复了 `calculateTotalEnergy () `中的原始回退索引以读取 `rawParams [1136]/[1137] `(系数 `0.01`)而不是 `rawValues [156]/[157]` 并添加了 2 位十进制舍入"
|
|
18
|
+
},
|
|
19
|
+
"1.0.4": {
|
|
20
|
+
"en": "Optimized V3.9x SHI Modbus Hybrid mode to achieve zero EEPROM write cycles during cycle optimization, pre-heating, and forced heating (uses volatile SHI offset `+10.0 K` via Holding 23 / `10002` instead of base point parameter `12`)\nFixed startup order in `onReady()` so Modbus TCP availability is checked before PV initialization and hardware ZIP timer disable runs after initial raw parameter fetch\nImproved PV startup recovery to only reset setpoints if a PV boost was actually active before restart, and decoupled PV heating boost from active SHI cycle optimization\nReleased SHI DHW mode (`10005 = 0`) when reverting hot water target to baseline and avoided unnecessary HUP voltage writes in `setIdleDefaults()` when HUP optimization is disabled",
|
|
21
|
+
"de": "Optimierter V3.9x SHI Modbus Hybrid-Modus für null EEPROM-Schreibzyklen bei Zyklusoptimierung, Vor- und Aufheizen (nutzt flüchtigen SHIOffset `+10,0 K` über Holding 23/`10002` statt Basispunktparameter `12`)\nDie Startreihenfolge in `onReady () `wurde korrigiert, sodass Modbus TCP vor der PV-Initialisierung geprüft wird und der ZIP-Timer nach dem ersten Raw-Parameterabruf\nVerbesserter PV-Startmodus, der nur Sollwerte zurücksetzt, wenn vor dem Start ein PV-Boost aktiv war, und PV-Heizboost von der SHI-Zyklusoptimierung entkoppelt\nGibt den SHI-DHW-Modus (`10005 = 0`) frei, wenn der Sollwert für Warmwasser auf Grundwert gesetzt wird, und vermeidet bei deaktivierter HUP-Optimierung",
|
|
22
|
+
"ru": "Оптимизированный гибридный режим SHI Modbus V3.9x для достижения нулевых циклов записи EEPROM во время оптимизации цикла, предварительного нагрева и принудительного нагрева (вместо параметра базовой точки «12» используется изменчивое смещение SHI «+10,0 K» за счет удержания 23/ «10002»)\nИсправлен порядок запуска в `onReady () `, поэтому доступность Modbus TCP проверяется до инициализации PV, а аппаратный таймер ZIP отключается после первоначальной выборки необработанных параметров\nУлучшено восстановление фотоэлектрической системы при запуске: заданные значения восстанавливаются только в том случае, если до перезапуска фотоэлектрическая система действительно была активна, а также отделите ускорение нагрева фотоэлектрической станции от активной оптимизации цикла SHI\nОтключен режим SHI DHW (`10005 = 0`) при возврате целевого значения горячей воды к исходному уровню и устранен ненужный режим записи напряжения HUP в `setIdleDefaults () `, когда оптимизация HUP отключена",
|
|
23
|
+
"pt": "Modo híbrido Modbus V3.9x SHI otimizado para zero ciclos de gravação EEPROM durante a otimização, pré-aquecimento e aquecimento forçado (usa offset SHI volátil `+10,0 K` via Holding 23/`10002` em vez do parâmetro base `12`)\nA ordem de inicialização em `onReady () `permite verificar a disponibilidade do Modbus TCP antes da inicialização do PV e desativar o ZIP timer após a busca inicial do parâmetro bruto\nRecuperação aprimorada da inicialização fotovoltaica para redefinir os pontos de ajuste somente se um reforço fotovoltaico estiver ativo e desacoplado da otimização ativa do ciclo SHI\nLançou o modo SHI DHW (`10005 = 0`) ao reverter o alvo de água quente para a linha de base e evitou gravações de tensão HUP em `setIdleDefaults () `ao desativar a otimização",
|
|
24
|
+
"nl": "Geoptimaliseerde V3.9x SHI Modbus Hybrid-modus om nul EEPROM-schrijfcycli te bereiken tijdens cyclusoptimalisatie, voorverwarming en geforceerde verwarming (maakt gebruik van vluchtige SHI-offset `+10,0 K` via Holding 23/`10002` in plaats van basispuntparameter `12`)\nOpstartvolgorde is opgelost in `OnReady () `, zodat de beschikbaarheid van Modbus TCP wordt gecontroleerd voordat de PV-initialisatie plaatsvindt en de ZIP-timer van de hardware wordt uitgeschakeld nadat de onbewerkte parameters zijn opgehaald\nVerbeterd herstel van de PV-opstart om de instelpunten alleen opnieuw in te stellen als er vóór de herstart daadwerkelijk een PV-boost actief was, en de PV-verwarmingsboost werd losgekoppeld van de actieve SHI-cyclusoptimalisatie\nDe SHI DHW-modus (`10005 = 0`) is vrijgegeven toen de warmwaterdoelstelling werd teruggezet naar de basislijn en werd onnodige HUP-spanning vermeden, geschreven in `setIdleDefaults () `wanneer de HUP-optimalisatie is uitgeschakeld",
|
|
25
|
+
"fr": "Mode hybride SHI Modbus V3.9x optimisé pour atteindre zéro cycle d'écriture EEPROM lors de l'optimisation, du préchauffage et du chauffage forcé (utilise un décalage SHI volatil « +10,0 K » en maintenant 23/« 10002 » au lieu du paramètre de base « 12 »)\nOrdre de démarrage fixe dans `onReady () `afin de vérifier la disponibilité du protocole Modbus TCP avant l'initialisation du PV et de désactiver le minuteur ZIP après la récupération des paramètres bruts\nAmélioration de la reprise au démarrage pour ne réinitialiser les points de consigne que si un boost PV était réellement actif avant le redémarrage, et isolation du chauffage PV de l'optimisation du cycle SHI actif\nA activé le mode SHI DHW (« 10005 = 0 ») lors du retour à la normale et évité les écritures inutiles de tension HUP dans setIdleDefaults () lorsque l'optimisation du HUP est désactivée",
|
|
26
|
+
"it": "Modalità SHI Modbus Hybrid V3.9x ottimizzata per zero cicli di scrittura EEPROM durante l'ottimizzazione del ciclo, il preriscaldamento e il riscaldamento forzato (usa l'offset SHI volatile `+10,0 K` via Holding 23/`10002` invece del parametro base `12`)\nOrdine di avvio fisso in `onReady () `per verificare la disponibilità del Modbus TCP prima dell'inizializzazione del PV e del timer ZIP hardware\nMigliore ripristino all'avvio del PV per azzerare i setpoint solo se il PV boost era attivo prima del riavvio e disaccoppiato dal ciclo SHI attivo\nHa attivato la modalità SHI DHW (`10005 = 0`) ripristinando il valore base di acqua calda ed evita inutili scritture di tensione HUP in `setIdleDefaults ()",
|
|
27
|
+
"es": "Modo Modbus Hybrid SHI V3.9x optimizado para lograr cero ciclos de escritura EEPROM durante la optimización del ciclo, el precalentamiento y el calentamiento forzado (utiliza un desfase SHI volátil de +10,0 K mediante Holding 23/ `10002` en lugar del parámetro de punto base `12`)\nSe ha fijado el orden de inicio en OnReady () para comprobar la disponibilidad de Modbus TCP antes de la inicialización de PV y la desactivación del temporizador ZIP por hardware tras la búsqueda inicial\nMejora de la recuperación de la energía fotovoltaica para restablecer solo los puntos de ajuste si un impulso fotovoltaico estaba realmente activo antes de reiniciarse y desacoplar el impulso de calefacción fotovoltaica de la optimización activa del ciclo SHI\nLanzó el modo DHW SHI (`10005 = 0') al revertir el objetivo de agua caliente a la base y evitó escribir voltaje HUP innecesarias en `setIdleDefaults () `cuando la optimización HUP está desactivada",
|
|
28
|
+
"pl": "Zoptymalizowany tryb hybrydowy v3.9x SHI Modbus do osiągnięcia zerowych cykli zapisu EEPROM podczas optymalizacji cyklu, podgrzewania wstępnego i wymuszonego ogrzewania (wykorzystuje lotne przesunięcie SHI `+10,0 K` poprzez Holding 23/`10002` zamiast parametru punktu bazowego `12`)\nNaprawiono kolejność uruchamiania w `onReady () `, dzięki czemu dostępność Modbus TCP jest sprawdzana przed inicjalizacją PV i wyłączeniem sprzętowego zegara ZIP po wstępnym pobraniu parametrów surowych\nUlepszone odzyskiwanie uruchamiania fotowoltaicznego w celu zresetowania wartości zadanych tylko wtedy, gdy wzmocnienie fotowoltaiczne było faktycznie aktywne przed ponownym uruchomieniem, i odłączenie wzmocnienia ogrzewania fotowoltaicznego od aktywnej optymalizacji cyklu SHI\nWydano tryb SHI CWU (`10005 = 0`) podczas przywracania celu ciepłej wody do linii bazowej i uniknięto niepotrzebnego zapisu napięcia HUP w `setIdleDefaults () `, gdy optymalizacja HUP jest wyłączona",
|
|
29
|
+
"uk": "Оптимізований гібридний режим V3.9x SHI Modbus для досягнення нульових циклів запису EEPROM під час оптимізації циклу, попереднього нагрівання та примусового нагрівання (використовує летючий зсув SHI `+10,0 K` через Holding 23/`10002` замість параметра базової точки `12`)\nВиправлено порядок запуску в `onReady () `, тому доступність Modbus TCP перевіряється перед ініціалізацією PV та відключенням апаратного ZIP таймера після початкового отримання необроблених параметрів\nПокращено відновлення запуску фотоелектричної енергії, щоб скинути задані значення лише в тому випадку, якщо підсилення фотоелектричної енергії було фактично активним перед перезапуском, і від'єднано прискорення фотоелектричного опалення від активної оптимізації циклу SHI\nВідпущений режим ГВП SHI (`10005 = 0`) при поверненні цілі гарячої води до базової лінії та уникнення непотрібних записів напруги HUP в `setIdleDefaults () `, коли оптимізація HUP відключена",
|
|
30
|
+
"zh-cn": "经过优化 V3.9x SHI Modbus 混合模式,在循环优化、预热和强制加热期间实现零 EEPROM 写入周期(使用 Holding 23/`10002` 的挥发性 SHI 偏移量 `+10.0 K`而不是基点参数 `12`)\n修复了 `onReady () `中的启动顺序,因此在 PV 初始化之前会检查 Modbus TCP 的可用性,并在提取初始原始参数后禁用硬件 ZIP 计时器运行\n改进了光伏启动恢复,只有在重启前实际处于活动状态的光伏助推器才会重置设定值,并将光伏加热提升与主动SHI循环优化解耦在一起\n在将热水目标恢复到基线时发布了 SHI DHW 模式(`10005 = 0`),并避免在禁用 HUP 优化时在 `setIdleDefaults () `中写入不必要的 HUP 电压"
|
|
31
|
+
},
|
|
6
32
|
"1.0.3": {
|
|
7
33
|
"en": "Fixed daily COP reset in `copManager.ts` so Heating and Hot Water values reset to `0` after midnight until an active cycle starts",
|
|
8
34
|
"de": "Der tägliche COP-Reset in `CopManager.TS` wurde behoben, sodass Heiz- und Warmwasserwerte bis Mitternacht auf 0 fallen",
|
|
@@ -67,32 +93,6 @@
|
|
|
67
93
|
"pl": "**Poprawiono tłumaczenia i18n**",
|
|
68
94
|
"uk": "**Виправлено переклади i18n**",
|
|
69
95
|
"zh-cn": "**修复了 i18n 翻译**"
|
|
70
|
-
},
|
|
71
|
-
"0.25.1": {
|
|
72
|
-
"en": "**Removed Dependencies:**\nWS",
|
|
73
|
-
"de": "**Abhängigkeiten entfernt: **\nWS",
|
|
74
|
-
"ru": "**Удаленные зависимости: **\nМЫ",
|
|
75
|
-
"pt": "**Dependências removidas: **\nS",
|
|
76
|
-
"nl": "**Afhankelijkheden verwijderd: **\nWS",
|
|
77
|
-
"fr": "**Dépendances supprimées :**\nWS",
|
|
78
|
-
"it": "**Dipendenze rimosse: **\nÈ",
|
|
79
|
-
"es": "**Dependencias eliminadas: **\nW",
|
|
80
|
-
"pl": "**Usunięte zależności: **\nWS",
|
|
81
|
-
"uk": "**Видалені залежності: **\nВС",
|
|
82
|
-
"zh-cn": "**移除的依赖关系:**\nWS"
|
|
83
|
-
},
|
|
84
|
-
"0.25.0": {
|
|
85
|
-
"en": "**Operating Mode & UI Protection (`jsonConfig.json`, `main.ts`):**\n**Explicit Operating Mode Selection:** Added a central selector in the Connection tab with color-coded status banners to clearly distinguish between **Read-Only (Monitoring)**, **Read & Write without Modbus (Native via Port 8889)**, and **Read & Write with Modbus TCP (Hybrid RAM access)**.\n**Dynamic UI & Backend Write Locking:** In Read-Only mode, all write-related configuration tabs (Modbus, Idle Defaults, Cycle Optimization, HUP, ZIP, PV Surplus) are automatically grayed out and all hardware write commands are strictly blocked in the backend.\n**Automatic Config Migration:** Existing installations are seamlessly migrated on startup to the matching operating mode based on previously active settings.\n**Modbus V3.9x Smart Home Interface (SHI) & Diagnostics (`modbusManager.ts`, `settings.ts`, `info.ts`):**\n**Dual-Protocol Auto-Detection:** The Modbus manager now automatically detects and supports both the classic Modbus register mapping (`0..23`) and the modern **V3.90+ / V3.92.x Smart Home Interface (SHI)** register architecture (`10000+`).\n**Automated SHI Mode-Gating:** Writing to SHI setpoints and offsets (`10001`, `10002`, `10006`) automatically activates the required SHI control mode registers (`10000`, `10005`, `10065`) and releases heating curve control (`mode = 0`) when the offset returns to `0 K`.\n**Granular Register Polling & Diagnostic Scanner:** Replaced rigid block reads with individual register polling to prevent `Exception 2 (Illegal data address)` crashes on unsupported registers, and integrated a full Modbus register scanner into `Dump_Raw_To_Log`.\n**Core Stability, COP & Pure TCP Communication (`main.ts`, `rawFunctions.ts`, `copManager.ts`):**\n**Pure Native TCP Architecture:** Removed deprecated WebSocket (port 8214) code in favor of stable, password-free native TCP communication over port `8889`.\n**Isolated COP & Energy Tracking:** Enforced strict separation of reference states for heating, hot water, and total consumption with fallback logic for controllers affected by zero-value firmware bugs.\n**Bug Fixes:** Fixed Modbus RAM vs. EEPROM sync loops (`hardwareOutOfSync`), unified `°C` temperature scaling across all data sources, and fixed offline detection (`info.connection` & `errorCount`) when telemetry reads fail.\n**Repository Checker & i18n:** Completed missing 11-language translations in `jsonConfig.json` and updated `@iobroker/testing` to `6.3.2`.",
|
|
86
|
-
"de": "**Betriebsmodus und UI-Schutz (`JSONConfig.JSON`, `main.ts`) :**\n**Explizite Betriebsartenwahl: ** Im Tab Verbindung wurde ein zentraler Selektor mit farbcodierten Statusbannern hinzugefügt, um klar zwischen **Read-Only (Monitoring) **, **Read & Write ohne Modbus (Native via Port 8889) ** und **Read & Write mit Modbus TCP (Hybrid-RAM-Zugriff) ** zu unterscheiden.\n**Dynamic UI & Backend Write Locking: ** Im Nur-Lesen-Modus sind alle Schreib-Tabs (Modbus, Idle Defaults, Cycle Optimization, HUP, ZIP, PV Surplus) automatisch ausgegraut und alle Hardware-Schreibbefehle im Backend strikt gesperrt.\n**Automatische Konfigurationsmigration: ** Bestehende Installationen werden beim Start auf Basis zuvor aktiver Einstellungen nahtlos umgestellt.\n**Modbus V3.9x Smart Home Interface (SHI) und Diagnose (`ModbusManager.ts`, `settings.ts`, `info.ts`) :**\n**Automatische Dual-Protocol-Erkennung: ** Der Modbus-Manager erkennt und unterstützt jetzt automatisch sowohl das klassische Modbus-Register-Mapping (`0.. 23`) als auch die moderne **V3.90+/V3.92.x Smart Home Interface (SHI) ** -Registerarchitektur (`10000+`).\n**Automatisches SHI-Modus-Gating: ** Das Schreiben in SHI-Sollwerte und Offsets (`10001`, `10002`, `10006`) aktiviert automatisch die erforderlichen SHI-Register (`10000`, `10005`, `10065`) und gibt die Heizkurvensteuerung frei (`mode = 0`), wenn der Offset auf `0 K` zurückgeht.\n**Granular Register Polling & Diagnostic Scanner: ** Starre Block-Lesevorgänge wurden durch einzelne Registerabfragen ersetzt, um Abstürze von `Exception 2 (Illegal data address) `auf ununterstützten Registern zu verhindern, und integrierte einen Modbus-Registerscanner in `Dump_Raw_To_Log`.\n**Kernstabilität, COP und reine TCP-Kommunikation (`main.ts`, `rawFunctions.ts`, `copManager.ts`) :**\n**Reine native TCP-Architektur: ** Veralteter WebSocket-Code (Port 8214) entfernt für stabile, passwortfreie TCP-Kommunikation über Port `8889`.\n**Isoliertes COP- und Energietracking: ** Strikte Trennung der Referenzwerte für Heizung, Warmwasser und Gesamtverbrauch mit Fallback-Logik für Regler mit Nullwert-Firmware-Bugs.\n**Bugfixes: ** Fixed Modbus RAM vs. EEPROM Sync Loops (`HardwareOutOfSync`), einheitliche `°C`-Temperaturskalierung für alle Datenquellen und feste Offline-Erkennung (`info.connection` & `errorCount`) bei Telemetrie-Lesevorgängen.\n**Repository Checker & i18n: ** Fehlende 11-sprachige Übersetzungen in `JSONConfig.json` ergänzt und @iobroker /testing `auf `6.3.2` aktualisiert.",
|
|
87
|
-
"ru": "**Режим работы и защита пользовательского интерфейса (`jsonConfig.json`, `main.ts`) :**\n**Явный выбор режима работы: **На вкладке «Подключение» добавлен центральный селектор с цветными баннерами состояния, позволяющими четко различать режимы «Только чтение» (мониторинг)** «Чтение и запись без Modbus» (встроенный порт 8889) **и «Чтение и запись с использованием Modbus TCP» (гибридный доступ к оперативной памяти)** \n**Динамическая блокировка записи пользовательского интерфейса и серверной части: ** В режиме «Только для чтения» все вкладки конфигурации, связанные с записью (Modbus, Idle Defaults, Cycle Optimization, HUP, ZIP, PV Surplus), автоматически выделяются серым цветом, а все команды аппаратной записи строго блокируются в серверной части.\n**Автоматическая миграция конфигураций: ** Существующие установки легко переносятся при запуске в соответствующий рабочий режим на основе ранее активных настроек.\n** Интерфейс умного дома Modbus V3.9x (SHI) и диагностика (`ModbusManager.ts`, `settings.ts`, `info.ts`) :**\n**Автоматическое обнаружение по двум протоколам: ** Диспетчер Modbus теперь автоматически обнаруживает и поддерживает как классическое отображение регистров Modbus (`0.. 23`), так и современную архитектуру регистров **V3.90+/ V3.92.x (SHI) ** (`10000+`).\n**Автоматическая регулировка режима SHI: ** Запись в заданные значения и смещения SHI (`10001`, `10002`, `10006`) автоматически активирует необходимые регистры режима управления SHI (`10000`, `10005`, `10065`) и отключает управление кривой нагрева (`режим = 0`), когда смещение возвращается к `0 K`.\n**Сканер детального опроса и диагностики регистров: ** Чтение жестких блоков заменено опросом отдельных регистров, чтобы предотвратить сбои «Исключения 2 (неправильный адрес данных)» в неподдерживаемых регистрах, и интегрировал полноценный сканер регистров Modbus в `Dump_Raw_To_Log`.\n** Стабильность ядра, COP и передача данных только по протоколу TCP (`main.ts`, `RawFunctions.ts`, `COPmanager.ts`) :**\n**Чистая нативная архитектура TCP: ** Удален устаревший код WebSocket (порт 8214) в пользу стабильной передачи данных по стандартному протоколу TCP без пароля через порт `8889`.\n**Изолированное отслеживание КПД и энергопотребления: ** Принудительное строгое разделение эталонных состояний отопления, горячей воды и общего потребления с использованием резервной логики для контроллеров, на которых обнаружены ошибки в микропрограммном обеспечении с нулевым значением.\n**Исправления ошибок: ** Исправлены циклы синхронизации Modbus RAM и EEPROM («HardwareOutOfSync»), унифицировано масштабирование температуры «°C» во всех источниках данных и исправлено обнаружение ошибок при чтении телеметрических данных в автономном режиме («info.connection» и «ErrorCount»).\n**Repository Checker и i18n: ** Исправлены недостающие переводы на 11 языков в `JsonConfig.json` и обновлены '@iobroker /testing `до `6.3.2`.",
|
|
88
|
-
"pt": "**Modo de operação e proteção UI (`jsonConfig.json`, `main.ts`) :**\n**Seleção explícita do modo operacional: ** Foi adicionado um seletor central na guia Conexão com banners de status codificados por cores para distinguir claramente entre **Read-Only (Monitoring) **, **Read & Write with Modbus TCP (Hybrid RAM access) **.\n**UI dinâmica e bloqueio de gravação de back-end: ** No modo somente leitura, todas as guias de gravação (Modbus, Idle Defaults, Cycle Optimization, HUP, ZIP, PV Surplus) ficam acinzentadas e todos os comandos de gravação de hardware são bloqueados no backend.\n**Migração automática de configuração: ** As instalações existentes são facilmente migradas para o modo operacional correspondente.\n**Interface doméstica inteligente Modbus V3.9x e diagnóstico (`ModbusManager.ts`, `settings.ts`, `info.ts`) :**\n**Detecção automática de protocolo duplo: **O gerenciador Modbus agora detecta e suporta automaticamente o mapeamento clássico do registro Modbus (`0.. 23`) e a moderna arquitetura de registro** 3.90+/ V3.92.x (`10000+`). \n**Controle automático do modo SHI: ** Gravar em pontos e offsets SHI (`10001`, `10002`, `10006`) ativa automaticamente os registros necessários do modo SHI (`10000`, `10005`, `10065`) e libera o controle da curva de aquecimento (`mode = 0`) quando o offset retorna a `0 K`.\n**Scanner de sondagem e diagnóstico granular: ** Substituiu as leituras de blocos rígidos pela sondagem individual para evitar que a `Exceção 2 (endereço de dados ilegal) `falhe em registros não suportados e integrou um scanner Modbus completo ao `Dump_Raw_To_Log`.\n**Core Stability, COP e comunicação TCP pura (`main.ts`, `rawFunctions.ts`, `copManager.ts`) :**\n**Arquitetura TCP nativa pura: ** Removido o código obsoleto do WebSocket (porta 8214) em favor da comunicação TCP nativa estável e sem senha pela porta `8889`.\n**COP isolado e rastreamento de energia: ** Separação estrita dos estados de referência para aquecimento, água quente e consumo total com lógica de retorno para controles com valor zero.\n**Correções de bugs: ** Corrigiu loops de sincronização Modbus RAM x EEPROM (`HardwareOutOfSync`), escala de temperatura de `°C unificada em todas as fontes de dados e fixou detecção offline (`info.connection` e `errorCount`) quando as leituras de telemetria falham.\n**Repository Checker e i18n: ** Concluiu as traduções faltantes em 11 idiomas em `jsonConfig.json` e atualizou `@iobroker /testing` para `6.3.2`.",
|
|
89
|
-
"nl": "**Besturingsmodus en UI-bescherming (`JSONConfig.json`, `main.ts`) :**\n**Expliciete keuze van de bedrijfsmodus: ** Een centrale selector toegevoegd op het tabblad Verbinding met statusbanners met kleurcodes om duidelijk onderscheid te maken tussen **Alleen-lezen (monitoring) **, **Lezen en schrijven zonder Modbus (standaard via poort 8889) ** en **Lezen en schrijven met Modbus TCP (hybride RAM-toegang) **.\n**Dynamische gebruikersinterface en schrijfvergrendeling in de backend: ** In de modus Alleen-lezen worden alle configuratietabbladen die verband houden met schrijven (Modbus, Idle Defaults, Cycle Optimization, HUP, ZIP, PV Surplus) automatisch grijs weergegeven en worden alle hardware-schrijfopdrachten strikt geblokkeerd in de backend.\n**Automatische migratie van de configuratie: ** Bestaande installaties worden bij het opstarten naadloos overgezet naar de bijbehorende bedrijfsmodus op basis van eerder actieve instellingen.\n**Modbus V3.9x Smart Home-interface (SHI) en diagnostiek (`ModbusManager.ts`, `settings.ts`, `info.ts`) :**\n**Automatische detectie met twee protocollen: ** De Modbus-manager detecteert en ondersteunt nu automatisch zowel de klassieke Modbus-registertoewijzing (`0.. 23`) als de moderne **V3.90+/v3.92.x Smart Home Interface (SHI) ** registerarchitectuur (`10000+`).\n**Geautomatiseerde SHI-modusgating: ** Als u naar SHI-setpoints en -offsets schrijft (`10001`, `10002`, `10006`) worden automatisch de vereiste SHI-regelmodusregisters (`10000`, `10005`, `10065`) geactiveerd en wordt de verwarmingscurve-regeling (`mode = 0`) vrijgegeven wanneer de offset terugkeert naar `0 K`.\n**Granular Register Polling & Diagnostic Scanner: ** Rigide bloklezen vervangen door individuele registerpeilingen om te voorkomen dat `Exception 2 (illegaal gegevensadres) `crasht op niet-ondersteunde registers, en een volledige Modbus-registerscanner geïntegreerd in `Dump_Raw_To_Log`.\n**Kernstabiliteit, COP en pure TCP-communicatie (`main.ts`, `RawFunctions.ts`, `COPManager.ts`) :**\n**Pure Native TCP-architectuur: ** Verouderde WebSocket-code (poort 8214) verwijderd ten gunste van stabiele, wachtwoordvrije native TCP-communicatie via poort `8889`.\n**Geïsoleerde COP- en energietracking: ** Zorgde voor een strikte scheiding van referentietoestanden voor verwarming, warm water en het totale verbruik, met terugvallogica voor controllers die getroffen zijn door firmwarefouten met een nulwaarde.\n**Bugreparaties: ** Vaste synchronisatielussen tussen Modbus RAM en EEPROM (`HardwareOutOfSync`), uniforme temperatuurschaling van `°C` voor alle gegevensbronnen, en vaste offline detectie (`info.connection` en `ErrorCount`) wanneer telemetrielezingen mislukken.\n**Repository Checker & i18n: ** Ontbrekende vertalingen in 11 talen voltooid in `JSONConfig.json` en `@iobroker /testing` bijgewerkt naar `6.3.2`.",
|
|
90
|
-
"fr": "**Mode opératoire et protection de l'UI (`JSONConfig.json`, `main.ts`) :**\n**Sélection explicite du mode de fonctionnement :** Ajout d'un sélecteur central dans l'onglet Connexion avec des bannières d'état codées par couleur pour faire clairement la distinction entre **ecture seule (surveillance)** **ecture et écriture sans Modbus (port natif via le port 8889)** et **ecture et écriture avec Modbus TCP (accès hybride à la RAM)** \n**Interface utilisateur dynamique et verrouillage de l'écriture : ** En mode lecture seule, tous les onglets de configuration liés à l'écriture (Modbus, Idle Defaults, Cycle Optimization, HUP, ZIP, PV Surplus) sont automatiquement grisés et toutes les commandes d'écriture sont bloquées dans le backend.\n**Migration automatique de la configuration :** Les installations existantes sont migrées facilement au démarrage vers le mode correspondant en fonction des paramètres actifs.\n**Interface domotique (SHI) Modbus v3.9x et diagnostics (« ModbusManager.ts », « settings.ts », « info.ts ») :**\n**Détection automatique à double protocole :** Le gestionnaire Modbus détecte et prend désormais en charge automatiquement le mappage de registres Modbus classique (« 0.. 23 ») et l'architecture de registre moderne **3.90+/V3.92.x Smart Home Interface (SHI)** (« 10000+ »). \n**Contrôle automatique du mode SHI :** L'écriture sur les points de réglage et les décalages SHI (« 10001 », « 10002 », « 10006 ») active automatiquement les registres du mode de contrôle SHI requis (« 10000 », « 10005 », « 10065 ») et active le contrôle de la courbe de chauffage (« mode = 0 ») lorsque le décalage revient à « 0 K ».\n**Scanner de diagnostic et de sondage granulaire : ** Les blocs rigides ont été remplacés par des sondages individuels pour éviter que « Exception 2 (adresse de données illégale) » ne plante sur des registres non pris en charge, et a intégré un scanner de registres Modbus complet dans « Dump_Raw_To_Log ».\n**Stabilité du noyau, COP et communication TCP pure (« main.ts », « RawFunctions.ts », « COPManager.ts ») :**\n**Architecture TCP native pure :** Le code WebSocket (port 8214) obsolète a été supprimé au profit d'une communication TCP native stable et sans mot de passe sur le port 8889.\n**COP isolé et suivi de l'énergie :** Séparation stricte des états de référence pour le chauffage, l'eau chaude et la consommation totale, avec une logique de secours pour les contrôleurs concernés par des bugs nuls.\n**Corrections de bugs :** Correction des boucles de synchronisation entre RAM Modbus et EEPROM (« HardwareOutOfSync »), ajustement unifié de la température en °C sur toutes les sources de données et correction de la détection hors ligne (info.connection et ErrorCount) en cas d'échec des relevés télémétriques.\n**Repository Checker et i18n :** A terminé les traductions manquantes en 11 langues dans `JSONConfig.json` et mis à jour `@iobroker /testing` en `6.3.2`.",
|
|
91
|
-
"it": "**Modo operativo e protezione UI (`JSONConfig.json`, `main.ts`) :**\n**Selezione esplicita della modalità operativa: ** Aggiunto un selettore centrale nella scheda Connessione con banner di stato colorati per distinguere chiaramente tra **Sola lettura (monitoraggio) **, **Lettura e scrittura senza Modbus (nativa tramite porta 8889) ** e **Lettura e scrittura con Modbus TCP (accesso RAM ibrido) **.\n**In modalità di sola lettura, tutte le schede di configurazione relative alla scrittura (Modbus, Idle Defaults, Cycle Optimization, HUP, ZIP, PV Surplus) sono automaticamente disattivate e tutti i comandi di scrittura hardware sono bloccati nel backend.\n**Migrazione automatica delle configurazioni: ** Le installazioni esistenti vengono migrate senza problemi all'avvio alla modalità operativa.\n**Interfaccia Smart Home Modbus v3.9x (SHI) e diagnostica (`ModbusManager.ts`, `settings.ts`, `info.ts`) :**\n**Rilevamento automatico a doppio protocollo: ** Il gestore Modbus ora rileva e supporta automaticamente sia la classica mappatura dei registri Modbus (`0.. 23`) che la moderna architettura di registro **V3.90+/V3.92.x (SHI) ** (`10000+).\n**Gating automatico della modalità SHI: ** La scrittura su setpoint e offset SHI (`10001`, `10002`, `10006`) attiva automaticamente i registri della modalità SHI richiesti (`10000`, `10005`, `10065`) e attiva il controllo della curva di riscaldamento (`mode=0`).\n**Scanner granulare per polling e diagnostica: ** Ha sostituito le letture a blocchi rigidi con il polling individuale per evitare che l'Exception 2 (indirizzo dati illegale) si blocchi su registri non supportati e ha integrato uno scanner Modbus completo in `Dump_Raw_To_Log`.\n**Core Stability, COP e comunicazione TCP pura (`main.ts`, `rawFunctions.ts`, `COPManager.ts`) :**\n**Architettura TCP nativa pura: ** Rimosso il codice WebSocket (porta 8214) obsoleto per una comunicazione TCP nativa stabile e senza password sulla porta `8889`.\n**COP isolato e tracciamento energetico: ** Separazione rigorosa degli stati di riferimento per riscaldamento, acqua calda e consumo totale con logica di riserva per i controller con bug del firmware zero.\n**Correzioni di bug: ** Loop di sincronizzazione Modbus RAM e EEPROM fissi (`HardwareOutOfSync`), scalabilità unificata `°C` su tutte le fonti di dati e rilevamento offline fisso (`info.connection` e `errorCount`) in caso di errore.\n**Repository Checker & i18n: ** Traduzioni mancanti in 11 lingue in `JSONConfig.json` e aggiornato `@iobroker /testing` a `6.3.2`.",
|
|
92
|
-
"es": "**Modo operativo y protección UI (`JsonConfig.JSON`, `main.ts`) :**\n**Selección explícita del modo de funcionamiento: ** Se ha añadido un selector central en la pestaña Conexión con anuncios de estado codificados por colores para distinguir claramente entre **Lectura (monitorización) **, **Leer y escribir sin Modbus (nativo a través del puerto 8889) ** y **Leer y escribir con Modbus TCP (acceso a RAM híbrida) **.\n**Bloqueo dinámico de escritura de backend: ** En modo de solo lectura, todas las pestañas de configuración de escritura (Modbus, Idle Defaults, Cycle Optimization, HUP, ZIP, PV Surplus) aparecen automáticamente en gris y todos los comandos de escritura del hardware se bloquean estrictamente en el backend.\n**Migración automática de la configuración: ** Las instalaciones existentes migran sin problemas al inicio al modo operativo correspondiente según los ajustes previamente activos.\n**Interfaz doméstica inteligente (SHI) Modbus v3.9x y diagnóstico (`ModbusManager.ts`, `settings.ts`, `info.ts`) :**\n**Detección automática de doble protocolo: ** El gestor de Modbus ahora detecta automáticamente y admite tanto la clásica asignación de registros Modbus (0.. 23) como la moderna arquitectura de registro **V3.90+/V3.92.x Smart Home Interface (SHI) ** (más de 10000).\n**Control automático del modo SHI: ** Escribir en los puntos de ajuste y desfase del SHI (10001, 10002, 10006) activa automáticamente los registros del modo de control SHI necesarios (10000, 10005, 10065) y activa el control de la curva de calentamiento (modo = 0) cuando el desfase vuelve a 0 K.\n**Escáner de sondeo y diagnóstico de registros granulares: ** Sustituyó las lecturas de bloques rígidos por sondeos de registro individuales para evitar que la «Excepción 2 (dirección de datos ilegal)» se bloquee en los registros no compatibles e integró un escáner Modbus completo en Dump_Raw_To_Log`.\n**Estabilidad básica, COP y comunicación TCP pura (`main.ts`, `RawFunctions.ts`, `CopManager.ts`) :**\n**Arquitectura TCP nativa pura: ** Se ha eliminado el código WebSocket (puerto 8214) obsoleto en favor de una comunicación TCP nativa estable y sin contraseñas por el puerto 8889.\n**COP y seguimiento energético aislados: ** Separó estrictamente los estados de referencia para calefacción, agua caliente y consumo total con lógica alternativa para los controladores afectados por errores de firmware sin valor.\n**Corrección de errores: ** Bucles fijos de sincronización Modbus RAM y EEPROM (`HardwareOutOfSync`), escalado de temperatura unificado en todas las fuentes de datos y detección fija fuera de línea (`info.connection` y `ErrorCount`) cuando fallan las lecturas de telemetría.\n**Repository Checker & i18n: ** Completó las traducciones a 11 idiomas que faltaban en `JSONConfig.json` y actualizó `@iobroker /testing` a `6.3.2».",
|
|
93
|
-
"pl": "**Tryb pracy i ochrona interfejsu użytkownika (`JSONConfig.json`, `main.ts`) :**\n**Wyraźny wybór trybu pracy: ** Dodano centralny selektor na karcie Połączenie z kolorowymi banerami stanu, aby wyraźnie rozróżnić między kategoriami **Tylko do odczytu (monitorowanie) **, **Odczyt i zapis bez Modbus (natywny przez port 8889) ** oraz **Odczyt i zapis z Modbus TCP (Hybrid RAM access) **.\n**Dynamiczne blokowanie zapisu interfejsu użytkownika i zaplecza: ** W trybie tylko do odczytu wszystkie karty konfiguracji związane z zapisem (Modbus, domyślne ustawienia bezczynności, optymalizacja cyklu, HUP, ZIP, nadwyżka PV) są automatycznie wyszarzone, a wszystkie sprzętowe polecenia zapisu są ściśle blokowane w zapleczu.\n**Automatyczna migracja konfiguracji: ** Istniejące instalacje są bezproblemowo migrowane po uruchomieniu do odpowiedniego trybu pracy w oparciu o wcześniej aktywne ustawienia.\n** Interfejs inteligentnego domu Modbus v3.9x (SHI) i diagnostyka (`ModbusManager.ts`, `settings.ts`, `info.ts`) :**\n**Automatyczne wykrywanie podwójnego protokołu: **Menedżer Modbus automatycznie wykrywa i obsługuje zarówno klasyczne mapowanie rejestru Modbus (`0.. 23`), jak i nowoczesną architekturę rejestru V3.90+/ v3.92.x Smart Home Interface (SHI)** (`10000+`). \n**Automatyczne przełączanie trybu SHI: ** Zapis do wartości zadanych i przesunięć SHI (`10001`, `10002`, `10006`) automatycznie aktywuje wymagane rejestry trybu sterowania SHI (`10000`, `10005`, `10065`) i zwalnia kontrolę krzywej ogrzewania (`mode = 0`), gdy przesunięcie powróci do `0 K`.\n**Granular Register Polling & Diagnostic Scanner: ** Zastąpiono sztywne odczyty bloków na indywidualne badanie rejestru, aby zapobiec awariom „Exception 2 (Nielegalny adres danych)” w nieobsługiwanych rejestrach i zintegrował pełny skaner rejestru Modbus do `Dump_Raw_To_Log`.\n** Stabilność rdzenia, komunikacja COP i czysta TCP (`main.ts`, `Rawfunctions.ts`, `CopManager.ts`) :**\n**Czysta natywna architektura TCP: ** Usunięto przestarzały kod WebSocket (port 8214) na rzecz stabilnej, wolnej od hasła natywnej komunikacji TCP przez port 8889.\n**Izolowane COP i śledzenie energii: ** Wymuszone ścisłe oddzielenie stanów odniesienia dla ogrzewania, ciepłej wody i całkowitego zużycia z logiką awaryjną dla kontrolerów dotkniętych błędami oprogramowania układowego o wartości zerowej.\n**Poprawki błędów: ** Naprawiono pętle synchronizacji Modbus RAM vs EEPROM (`HardwareOutOfSync`), ujednolicone skalowanie temperatury `°C` we wszystkich źródłach danych i poprawiono wykrywanie offline (`info.connection` i `ErrorCount`), gdy odczyty telemetrii nie powiodły się.\n**Repository Checker & i18n: ** Ukończono brakujące 11-językowe tłumaczenia w `JSONConfig.json` i zaktualizowano `@iobroker /testing` do `6.3.2 `.",
|
|
94
|
-
"uk": "**Режим роботи та захист інтерфейсу користувача (`JsonConfig.json`, `main.ts`) :**\n**Вибір явного режиму роботи: ** Додано центральний селектор на вкладці Підключення з кольоровими банерами статусу, щоб чітко розрізняти **Тільки для читання (моніторинг) **, **Читання та запис без Modbus (рідний через порт 8889) ** та **Читання та запис за допомогою Modbus TCP (гібридний доступ до оперативної пам'яті) **.\n**Динамічне блокування інтерфейсу користувача та резервного запису: ** У режимі лише для читання всі вкладки конфігурації, пов'язані з записом (Modbus, Idle Defaults, Cycle Optimization, HUP, ZIP, PV Surplus) автоматично відображаються сірим кольором, а всі команди запису апаратного забезпечення строго блокуються в серверній частині.\n**Автоматична міграція конфігурацій: ** Існуючі інсталяції безперешкодно переносяться при запуску в відповідний робочий режим на основі раніше активних налаштувань.\n** Інтерфейс розумного будинку Modbus V3.9x (SHI) та діагностика (`ModbusManager.ts`, `налаштування.ts`, `info.ts`) :**\n**Автоматичне виявлення подвійного протоколу: ** Менеджер Modbus тепер автоматично виявляє та підтримує як класичне відображення регістрів Modbus (`0.. 23`), так і сучасну архітектуру реєстру **V3.90+/ v3.92.x Smart Home Interface (SHI) ** (`10000+`).\n**Автоматизований режим SHI: ** Запис до встановлених точок та зміщення SHI (`10001`, `10002`, `10006`) автоматично активує необхідні регістри режиму управління SHI (`10000`, `10005`, `10065`) та випускає контроль кривої нагріву (`mode = 0`), коли зміщення повертається до `0 K`.\n**Гранульований реєстр опитування та діагностичний сканер: ** Замінено жорстке блокове читання окремим опитуванням реєстрів, щоб запобігти збоям `Виняток 2 (Незаконна адреса даних) `на непідтримуваних регістрах та інтегрував повний сканер регістрів Modbus в `Dump_Raw_To_Log`.\n** Основна стабільність, COP та чистий зв'язок TCP (`main.ts`, `RAWFunctions.ts`, `CopManager.ts`) :**\n**Чиста рідна архітектура TCP: ** Вилучено застарілий код WebSocket (порт 8214) на користь стабільного нативного TCP-зв'язку без паролів через порт `8889`.\n**Ізольоване відстеження COP та енергії: ** Примусово суворе розділення еталонних станів для опалення, гарячої води та загального споживання із запасною логікою для контролерів, які постраждали від помилок мікропрограмного забезпечення з нульовим значенням.\n**Виправлення помилок: ** Виправлено цикли синхронізації оперативної пам'яті Modbus проти EEPROM (`HardwareOutOfSync`), уніфіковане масштабування температури `°C` у всіх джерелах даних та виправлене виявлення в автономному режимі (`info.connection` & `ErrorCount`), коли зчитування телеметрії не вдається.\n**Перевірка сховищ & i18n: ** Завершено відсутні 11-мовні переклади в `JsonConfig.json` та оновлено `@iobroker /testing` до `6.3.2`.",
|
|
95
|
-
"zh-cn": "**操作模式和用户界面保护(`jsonConfig.json`,`main.ts`):**\n**明确的操作模式选择:** 在 “连接” 选项卡中添加了带有颜色编码状态横幅的中央选择器,以明确区分**只读(监控)**、**不使用 Modbus 的读取和写入(通过端口 8889 原生)**和**使用 Modbus TCP 读取和写入(混合 RAM 访问权限)**。\n**动态用户界面和后端写入锁定:** 在只读模式下,所有与写入相关的配置选项卡(Modbus、空闲默认值、周期优化、HUP、ZIP、PV 剩余)自动显示为灰色,所有硬件写入命令在后端都被严格阻止。\n**自动配置迁移:** 现有安装在启动时会根据先前激活的设置无缝迁移到匹配的操作模式。\n**Modbus v3.9x 智能家居接口 (SHI) 和诊断(`ModbusManager.ts`、`setts.ts`、`info.ts`):**\n**双协议自动检测:** Modbus 管理器现在可以自动检测并支持经典的 Modbus 寄存器映射(`0... 23`)和现代的 **3.90+/v3.92.x 智能家居接口 (SHI)** 寄存器架构 (`10000+`)。 \n**自动 SHI 模式门控:** 写入 SHI 设定值和偏移量(`10001`、`10002`、`10006`)会自动激活所需的 SHI 控制模式寄存器(`10000`、`10005`、`10065`),并在偏移量恢复到 `0 K`时释放加热曲线控制(`模式 = 0`)。\n**精细寄存器轮询和诊断扫描器:** 使用单个寄存器轮询取代了刚性块读取,以防止 “异常 2(非法数据地址)” 在不受支持的寄存器上崩溃,并将完整的 Modbus 寄存器扫描器集成到 `Dump_Raw_To_Log`中。\n**核心稳定性、COP 和纯 TCP 通信(`main.ts`、`rawFunctions.ts`、`copManager.ts`):**\n**纯原生 TCP 架构:** 移除了过时的 WebSocket(端口 8214)代码,转而通过端口 `8889` 进行稳定、无密码的本地 TCP 通信。\n**隔离 COP 和能量跟踪:** 针对受零值固件错误影响的控制器,使用备用逻辑严格分离供暖、热水和总消耗的参考状态。\n**错误修复:** 修复了Modbus RAM与EEPROM同步回路(`HardwareOutOfSync`),统一了所有数据源的温度调节,并修复了遥测读取失败时的离线检测(`info.connection`和`errorCount`)。\n**Repository Checker & i18n:** 完成了 `jsonConfig.json` 中缺失的 11 种语言的翻译,并将 @iobroker /testing 更新为 6.3.2。"
|
|
96
96
|
}
|
|
97
97
|
},
|
|
98
98
|
"titleLang": {
|