iobroker.luxtronik2-controller 0.25.2 → 1.0.1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/README.md CHANGED
@@ -102,6 +102,14 @@ You might see red error messages in the installation log related to `node-gyp`,
102
102
  //### **WORK IN PROGRESS**
103
103
 
104
104
  ## Changelog
105
+ ### 1.0.1 (2026-11-16)
106
+
107
+ - **Update of i10n files**
108
+
109
+ ### 1.0.0 (2026-11-16)
110
+
111
+ **STABLE**
112
+
105
113
  ### 0.25.2 (2026-11-16)
106
114
 
107
115
  - **Fix i18n**
@@ -127,22 +135,6 @@ You might see red error messages in the installation log related to `node-gyp`,
127
135
  - **Bug Fixes:** Fixed Modbus RAM vs. EEPROM sync loops (`hardwareOutOfSync`), unified `°C` temperature scaling across all data sources, and fixed offline detection (`info.connection` & `errorCount`) when telemetry reads fail.
128
136
  - **Repository Checker & i18n:** Completed missing 11-language translations in `jsonConfig.json` and updated `@iobroker/testing` to `6.3.2`.
129
137
 
130
- ### 0.24.0 (2026-11-09)
131
-
132
- **🐛 Bugfixes & Tweaks**
133
-
134
- - **Operating Mode & Write Protection (`jsonConfig.json`, `main.ts`):**
135
- - **Explicit Operating Mode Selection:** Added a central "Operating Mode" selector in the Connection tab with color-coded status banners to clearly distinguish between **Read-Only (Monitoring)**, **Read & Write without Modbus (Native via Port 8889)**, and **Read & Write with Modbus TCP (Hybrid RAM access)**.
136
- - **Dynamic UI Locking:** When "Read-Only" is selected, all write-related configuration tabs (Modbus, Idle Defaults, Cycle Optimization, HUP, ZIP, and PV Surplus) and their inputs are automatically grayed out and disabled. Selecting native write mode unlocks the optimization tabs while keeping the Modbus tab disabled.
137
- - **Strict Backend Write Lock:** Enforced a global hardware write lock in Read-Only mode across `onReady`, `syncConfigValue`, `runOptimizationSchedule`, and `onStateChange` (while keeping diagnostic functions like debug logging, raw dumps, and firmware checks active).
138
- - **Automatic Config Migration:** Existing installations are seamlessly migrated on startup to the matching operating mode based on their previously active Modbus and optimization settings.
139
-
140
- ### 0.23.2 (2026-11-07)
141
-
142
- - **COP & Efficiency Calculation (`copManager.ts`):**
143
- - **Isolated Counter Tracking:** Introduced dedicated reference states for Total, Heating, and Hot Water counters (`last_raw_power_*` and `last_raw_thermal_*`). Each counter is now compared strictly against its own previous value, completely preventing cross-mode "ghost deltas" and astronomical COP spikes during cycle transitions.
144
- - **Automatic Total-Delta Fallback:** Added seamless fallback detection for controllers with firmware bugs (e.g., Novelan LAV) where mode-specific counters like `energy_warmwater` remain permanently at `0`. If a specific counter reports a delta of `0` during an active cycle, the adapter automatically uses the live delta of the corresponding total counter (`energy_total` / `thermalenergy_total`) without requiring manual configuration workarounds.
145
-
146
138
  ## License
147
139
 
148
140
  MIT License