iobroker.luxtronik2-controller 0.25.0 → 0.25.2
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/README.md +9 -15
- package/admin/i18n/uk.json +537 -1
- package/admin/i18n/zh-cn.json +806 -1
- package/io-package.json +27 -27
- package/package.json +2 -3
package/README.md
CHANGED
|
@@ -102,6 +102,15 @@ You might see red error messages in the installation log related to `node-gyp`,
|
|
|
102
102
|
//### **WORK IN PROGRESS**
|
|
103
103
|
|
|
104
104
|
## Changelog
|
|
105
|
+
### 0.25.2 (2026-11-16)
|
|
106
|
+
|
|
107
|
+
- **Fix i18n**
|
|
108
|
+
|
|
109
|
+
### 0.25.1 (2026-11-16)
|
|
110
|
+
|
|
111
|
+
- **Removed Dependencies:**
|
|
112
|
+
- WS
|
|
113
|
+
|
|
105
114
|
### 0.25.0 (2026-11-16)
|
|
106
115
|
|
|
107
116
|
- **Operating Mode & UI Protection (`jsonConfig.json`, `main.ts`):**
|
|
@@ -134,21 +143,6 @@ You might see red error messages in the installation log related to `node-gyp`,
|
|
|
134
143
|
- **Isolated Counter Tracking:** Introduced dedicated reference states for Total, Heating, and Hot Water counters (`last_raw_power_*` and `last_raw_thermal_*`). Each counter is now compared strictly against its own previous value, completely preventing cross-mode "ghost deltas" and astronomical COP spikes during cycle transitions.
|
|
135
144
|
- **Automatic Total-Delta Fallback:** Added seamless fallback detection for controllers with firmware bugs (e.g., Novelan LAV) where mode-specific counters like `energy_warmwater` remain permanently at `0`. If a specific counter reports a delta of `0` during an active cycle, the adapter automatically uses the live delta of the corresponding total counter (`energy_total` / `thermalenergy_total`) without requiring manual configuration workarounds.
|
|
136
145
|
|
|
137
|
-
### 0.23.1 (2026-11-07)
|
|
138
|
-
|
|
139
|
-
- **COP & Efficiency Calculation Fix (`copManager.ts`):**
|
|
140
|
-
- **Fixed Astronomical COP Values:** Resolved a critical bug where the internal calculation logic switched between specific and total energy counters, causing massive "ghost deltas" and resulting in astronomical COP values (e.g., > 1000).
|
|
141
|
-
- **Restored Robust Routing:** The adapter now strictly and safely relies on the continuous total counters (`energy_total` and `thermalenergy_total`). It calculates the delta over the polling interval and dynamically routes it into the Heating or Hot Water buckets based on the active operating state.
|
|
142
|
-
- _Note:_ Users facing the hardware bug where the heat pump does not track DHW power internally should select "External Object ID" in the adapter settings and link their `energy_total` datapoint as a workaround.
|
|
143
|
-
|
|
144
|
-
### 0.23.0 (2026-11-07)
|
|
145
|
-
|
|
146
|
-
**🐛 Bugfixes & Tweaks**
|
|
147
|
-
|
|
148
|
-
- **Configuration & Baseline Logic:**
|
|
149
|
-
- **Custom Heating Offset Baseline:** Added a new configuration field in the "Idle Defaults" tab for the default heating target temperature offset (Parallelverschiebung)[cite: 10].
|
|
150
|
-
- **Preserved Baselines:** The idle reset mechanism (`main.ts`) and the PV surplus manager (`pvManager.ts`) now respect this custom baseline (e.g., +1 K) instead of hard-resetting the offset to `0 K`[cite: 7, 13]. This ensures that your manual baseline heating curve is perfectly preserved when returning from a PV boost or entering standby.
|
|
151
|
-
|
|
152
146
|
## License
|
|
153
147
|
|
|
154
148
|
MIT License
|