iobroker.luxtronik2-controller 0.25.0 → 0.25.1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/README.md +5 -8
- package/io-package.json +14 -14
- package/package.json +2 -3
package/README.md
CHANGED
|
@@ -102,6 +102,11 @@ You might see red error messages in the installation log related to `node-gyp`,
|
|
|
102
102
|
//### **WORK IN PROGRESS**
|
|
103
103
|
|
|
104
104
|
## Changelog
|
|
105
|
+
### 0.25.1 (2026-11-16)
|
|
106
|
+
|
|
107
|
+
- **Removed Dependencies:**
|
|
108
|
+
- WS
|
|
109
|
+
|
|
105
110
|
### 0.25.0 (2026-11-16)
|
|
106
111
|
|
|
107
112
|
- **Operating Mode & UI Protection (`jsonConfig.json`, `main.ts`):**
|
|
@@ -141,14 +146,6 @@ You might see red error messages in the installation log related to `node-gyp`,
|
|
|
141
146
|
- **Restored Robust Routing:** The adapter now strictly and safely relies on the continuous total counters (`energy_total` and `thermalenergy_total`). It calculates the delta over the polling interval and dynamically routes it into the Heating or Hot Water buckets based on the active operating state.
|
|
142
147
|
- _Note:_ Users facing the hardware bug where the heat pump does not track DHW power internally should select "External Object ID" in the adapter settings and link their `energy_total` datapoint as a workaround.
|
|
143
148
|
|
|
144
|
-
### 0.23.0 (2026-11-07)
|
|
145
|
-
|
|
146
|
-
**🐛 Bugfixes & Tweaks**
|
|
147
|
-
|
|
148
|
-
- **Configuration & Baseline Logic:**
|
|
149
|
-
- **Custom Heating Offset Baseline:** Added a new configuration field in the "Idle Defaults" tab for the default heating target temperature offset (Parallelverschiebung)[cite: 10].
|
|
150
|
-
- **Preserved Baselines:** The idle reset mechanism (`main.ts`) and the PV surplus manager (`pvManager.ts`) now respect this custom baseline (e.g., +1 K) instead of hard-resetting the offset to `0 K`[cite: 7, 13]. This ensures that your manual baseline heating curve is perfectly preserved when returning from a PV boost or entering standby.
|
|
151
|
-
|
|
152
149
|
## License
|
|
153
150
|
|
|
154
151
|
MIT License
|
package/io-package.json
CHANGED
|
@@ -1,8 +1,21 @@
|
|
|
1
1
|
{
|
|
2
2
|
"common": {
|
|
3
3
|
"name": "luxtronik2-controller",
|
|
4
|
-
"version": "0.25.
|
|
4
|
+
"version": "0.25.1",
|
|
5
5
|
"news": {
|
|
6
|
+
"0.25.1": {
|
|
7
|
+
"en": "**Removed Dependencies:**\nWS",
|
|
8
|
+
"de": "**Abhängigkeiten entfernt: **\nWS",
|
|
9
|
+
"ru": "**Удаленные зависимости: **\nМЫ",
|
|
10
|
+
"pt": "**Dependências removidas: **\nS",
|
|
11
|
+
"nl": "**Afhankelijkheden verwijderd: **\nWS",
|
|
12
|
+
"fr": "**Dépendances supprimées :**\nWS",
|
|
13
|
+
"it": "**Dipendenze rimosse: **\nÈ",
|
|
14
|
+
"es": "**Dependencias eliminadas: **\nW",
|
|
15
|
+
"pl": "**Usunięte zależności: **\nWS",
|
|
16
|
+
"uk": "**Видалені залежності: **\nВС",
|
|
17
|
+
"zh-cn": "**移除的依赖关系:**\nWS"
|
|
18
|
+
},
|
|
6
19
|
"0.25.0": {
|
|
7
20
|
"en": "**Operating Mode & UI Protection (`jsonConfig.json`, `main.ts`):**\n**Explicit Operating Mode Selection:** Added a central selector in the Connection tab with color-coded status banners to clearly distinguish between **Read-Only (Monitoring)**, **Read & Write without Modbus (Native via Port 8889)**, and **Read & Write with Modbus TCP (Hybrid RAM access)**.\n**Dynamic UI & Backend Write Locking:** In Read-Only mode, all write-related configuration tabs (Modbus, Idle Defaults, Cycle Optimization, HUP, ZIP, PV Surplus) are automatically grayed out and all hardware write commands are strictly blocked in the backend.\n**Automatic Config Migration:** Existing installations are seamlessly migrated on startup to the matching operating mode based on previously active settings.\n**Modbus V3.9x Smart Home Interface (SHI) & Diagnostics (`modbusManager.ts`, `settings.ts`, `info.ts`):**\n**Dual-Protocol Auto-Detection:** The Modbus manager now automatically detects and supports both the classic Modbus register mapping (`0..23`) and the modern **V3.90+ / V3.92.x Smart Home Interface (SHI)** register architecture (`10000+`).\n**Automated SHI Mode-Gating:** Writing to SHI setpoints and offsets (`10001`, `10002`, `10006`) automatically activates the required SHI control mode registers (`10000`, `10005`, `10065`) and releases heating curve control (`mode = 0`) when the offset returns to `0 K`.\n**Granular Register Polling & Diagnostic Scanner:** Replaced rigid block reads with individual register polling to prevent `Exception 2 (Illegal data address)` crashes on unsupported registers, and integrated a full Modbus register scanner into `Dump_Raw_To_Log`.\n**Core Stability, COP & Pure TCP Communication (`main.ts`, `rawFunctions.ts`, `copManager.ts`):**\n**Pure Native TCP Architecture:** Removed deprecated WebSocket (port 8214) code in favor of stable, password-free native TCP communication over port `8889`.\n**Isolated COP & Energy Tracking:** Enforced strict separation of reference states for heating, hot water, and total consumption with fallback logic for controllers affected by zero-value firmware bugs.\n**Bug Fixes:** Fixed Modbus RAM vs. EEPROM sync loops (`hardwareOutOfSync`), unified `°C` temperature scaling across all data sources, and fixed offline detection (`info.connection` & `errorCount`) when telemetry reads fail.\n**Repository Checker & i18n:** Completed missing 11-language translations in `jsonConfig.json` and updated `@iobroker/testing` to `6.3.2`.",
|
|
8
21
|
"de": "**Betriebsmodus und UI-Schutz (`JSONConfig.JSON`, `main.ts`) :**\n**Explizite Betriebsartenwahl: ** Im Tab Verbindung wurde ein zentraler Selektor mit farbcodierten Statusbannern hinzugefügt, um klar zwischen **Read-Only (Monitoring) **, **Read & Write ohne Modbus (Native via Port 8889) ** und **Read & Write mit Modbus TCP (Hybrid-RAM-Zugriff) ** zu unterscheiden.\n**Dynamic UI & Backend Write Locking: ** Im Nur-Lesen-Modus sind alle Schreib-Tabs (Modbus, Idle Defaults, Cycle Optimization, HUP, ZIP, PV Surplus) automatisch ausgegraut und alle Hardware-Schreibbefehle im Backend strikt gesperrt.\n**Automatische Konfigurationsmigration: ** Bestehende Installationen werden beim Start auf Basis zuvor aktiver Einstellungen nahtlos umgestellt.\n**Modbus V3.9x Smart Home Interface (SHI) und Diagnose (`ModbusManager.ts`, `settings.ts`, `info.ts`) :**\n**Automatische Dual-Protocol-Erkennung: ** Der Modbus-Manager erkennt und unterstützt jetzt automatisch sowohl das klassische Modbus-Register-Mapping (`0.. 23`) als auch die moderne **V3.90+/V3.92.x Smart Home Interface (SHI) ** -Registerarchitektur (`10000+`).\n**Automatisches SHI-Modus-Gating: ** Das Schreiben in SHI-Sollwerte und Offsets (`10001`, `10002`, `10006`) aktiviert automatisch die erforderlichen SHI-Register (`10000`, `10005`, `10065`) und gibt die Heizkurvensteuerung frei (`mode = 0`), wenn der Offset auf `0 K` zurückgeht.\n**Granular Register Polling & Diagnostic Scanner: ** Starre Block-Lesevorgänge wurden durch einzelne Registerabfragen ersetzt, um Abstürze von `Exception 2 (Illegal data address) `auf ununterstützten Registern zu verhindern, und integrierte einen Modbus-Registerscanner in `Dump_Raw_To_Log`.\n**Kernstabilität, COP und reine TCP-Kommunikation (`main.ts`, `rawFunctions.ts`, `copManager.ts`) :**\n**Reine native TCP-Architektur: ** Veralteter WebSocket-Code (Port 8214) entfernt für stabile, passwortfreie TCP-Kommunikation über Port `8889`.\n**Isoliertes COP- und Energietracking: ** Strikte Trennung der Referenzwerte für Heizung, Warmwasser und Gesamtverbrauch mit Fallback-Logik für Regler mit Nullwert-Firmware-Bugs.\n**Bugfixes: ** Fixed Modbus RAM vs. EEPROM Sync Loops (`HardwareOutOfSync`), einheitliche `°C`-Temperaturskalierung für alle Datenquellen und feste Offline-Erkennung (`info.connection` & `errorCount`) bei Telemetrie-Lesevorgängen.\n**Repository Checker & i18n: ** Fehlende 11-sprachige Übersetzungen in `JSONConfig.json` ergänzt und @iobroker /testing `auf `6.3.2` aktualisiert.",
|
|
@@ -80,19 +93,6 @@
|
|
|
80
93
|
"pl": "* 🐛 Poprawki błędów i poprawki**\n\n**COP i obliczanie wydajności („CopManager.ts”) :**\n**Błąd sprzętu gorącej wody: ** Dodano dynamiczny mechanizm awaryjny, aby ominąć błąd sprzętowy występujący w kilku firmwareach Luxtronik i Novelan, w których wewnętrzny licznik elektryczny ciepłej wody („energy_warmwater”) na stałe zgłasza `0`.\n**Smart Delta Routing: ** Gdy pompa ciepła aktywnie wytwarza ciepłą wodę (`WP_BZ_Akt === 1`), kierownik COP sprawdza teraz, czy wewnętrzny miernik mocy cieplnej utknął na zerowym poziomie. Jeśli tak, automatycznie przechwytuje deltę z licznika energii całkowitej („energy_total”) w ostatnim przedziale sondażu i bezpiecznie kieruje ją do wiadra COP ciepłej wody.\n**Ciągła synchronizacja czuwania: ** Ulepszono śledzenie bazy danych, aby zapewnić ciągłą synchronizację licznika rezerwowego całkowitej energii nawet w trybie czuwania lub ogrzewania. Zapobiega to gromadzeniu się zużycia energii na biegu jałowym w tle i fałszywym zniekształceniu następnego obliczenia efektywności ciepłej wody.",
|
|
81
94
|
"uk": "* 🐛 Виправлення помилок та налаштування**\n\n**Розрахунок COP та ефективності (`CopManager.ts`) :**\n**Запасна помилка гарячої води: ** Додано динамічний резервний механізм для обходу апаратної помилки, присутньої в декількох прошивках Luxtronik та Novelan, де внутрішній електричний лічильник гарячої води (`energy_warmwater`) постійно повідомляє `0`.\n**Розумна дельта-маршрутизація: ** Коли тепловий насос активно генерує гарячу воду (`WP_BZ_Akt === 1`), менеджер COP тепер перевіряє, чи застряг внутрішній лічильник потужності ГВП на нулі. Якщо так, він автоматично перехоплює дельту з лічильника загальної енергії (`energy_total`) протягом останнього інтервалу опитування та надійно направляє її у відро COP гарячої води.\n**Безперервна синхронізація в режимі очікування: ** Покращено відстеження бази даних, щоб гарантувати постійну синхронізацію лічильника загальної запасної енергії навіть у режимі очікування або нагрівання. Це запобігає накопиченню споживання енергії на холостому режимі у фоновому режимі та помилковому спотворенню наступного розрахунку ефективності гарячої води.",
|
|
82
95
|
"zh-cn": "* 🐛 错误修复和调整**\n\n**COP 和效率计算 (`copManager.ts`): **\n**热水硬件错误备份:**添加了动态备用机制,以绕过几款Luxtronik和Novelan固件中存在的硬件错误,在该错误中,内部热水电表(“energy_warmwater”)永久报告为 “0”。\n**智能三角路由:** 当热泵主动产生热水(`wp_bz_AKT === 1`)时,COP 管理器现在会检查内部 DHW 功率计是否停留在零。如果是,它会在最后一个轮询间隔内自动拦截总能量计(“energy_total”)中的增量,并将其安全地路由到热水 COP 存储桶中。\n**持续待机同步:** 增强了数据库跟踪,确保即使在待机或加热模式下,总能量回退计数器也能持续同步。这样可以防止空闲功耗在后台累积,从而错误地扭曲下一次的热水效率计算。"
|
|
83
|
-
},
|
|
84
|
-
"0.22.7": {
|
|
85
|
-
"en": "*🐛 Bugfixes**\n\n**PV Surplus Management & Cycle Optimization:**\n**Zero-Drift Baseline Calculation:** Rewrote the PV boost baseline logic in `pvManager.ts`. The adapter no longer reads live datapoint states to calculate the boost, but strictly enforces the configured baseline values (`sync_warmwater_target_temperature` and `0K` for heating). This permanently resolves the \"snowball effect\" where the hot water target could incrementally drift up to the 70 °C safety limit.\n**Cycle Coupling Handshake:** Enhanced the intelligent cycle optimization (`main.ts`) during active PV surplus. At the end of a heating cycle, the adapter now seamlessly couples a hot water cycle and intelligently enforces the PV boost target (e.g., 60 °C) to maximize solar self-consumption, without interfering with the strict baseline logic.",
|
|
86
|
-
"de": "* 🐛 Bugfixes**\n\n**PV-Überschussmanagement und Zyklusoptimierung: **\n**Null-Drift-Basisberechnung: ** Die PV-Boost-Basislogik in `PVManager.ts` neu geschrieben. Der Adapter liest keine Live-Daten mehr, um den Boost zu berechnen, sondern setzt strikt die eingestellten Basiswerte um (`sync_warmwater_target_temperature` und `0K` für Heizung). Das löst dauerhaft den „Schneeballeffekt“ auf, bei dem das Heißwasserziel schrittweise auf 70 °C driften kann.\n**Cycle Coupling Handshake: ** Verbesserte Zyklusoptimierung (`main.ts`) bei aktivem PV-Überschuss. Am Ende eines Heizzyklus koppelt der Adapter nun nahtlos einen Warmwasserkreislauf an und setzt das PV-Boost-Ziel (z. B. 60 °C) intelligent um, um den Eigenverbrauch der Sonne zu maximieren, ohne die Grundlogik zu stören.",
|
|
87
|
-
"ru": "* 🐛 Исправления ошибок**\n\n**Управление излишками фотоэлектрических установок и оптимизация циклов: **\n**Расчет базового уровня нулевого дрейфа: ** Переписана базовая логика усиления фотоэлектрических систем в `PVmanager.ts`. Адаптер больше не считывает состояния точек данных в реальном времени для расчета коэффициента усиления, а строго соблюдает настроенные базовые значения (`sync_warmwater_target_temperature` и `0K` для нагрева). Это навсегда устраняет «эффект снежного кома», когда целевой уровень горячей воды может постепенно доходить до безопасного предела 70 °C.\n**Рукопожатие Cycle Coupling: ** Улучшена интеллектуальная оптимизация цикла (`main.ts`) при активном избытке фотоэлектрических систем. В конце цикла нагрева адаптер теперь беспрепятственно подключается к циклу горячей воды и интеллектуально обеспечивает повышение температуры фотоэлектрических систем (например, до 60 °C), обеспечивая максимальное потребление солнечной энергии, не нарушая при этом строгой базовой логики.",
|
|
88
|
-
"pt": "* 🐛 Correções**\n\n**Gestão do excedente fotovoltaico e otimização do ciclo: **\n**Cálculo do Zero-Drift: ** Reescreveu a lógica básica do PV boost em `PVManager.ts`. O adaptador não lê mais os estados ativos dos pontos de dados para calcular o aumento, mas aplica rigorosamente os valores básicos (`sync_warmwater_target_temperature` e `0K` para aquecimento). Isso resolve permanentemente o “efeito bola de neve”, em que a meta de água quente pode subir até o limite de segurança de 70 °C.\n**Cycle Coupling Handshake: ** Melhorou a otimização inteligente do ciclo (`main.ts`) durante o excedente de PV ativo. No final do ciclo de aquecimento, o adaptador agora acopla perfeitamente o ciclo de água quente e impõe a meta de aumento fotovoltaico (por exemplo, 60 °C) para maximizar o consumo solar, sem interferir na lógica básica.",
|
|
89
|
-
"nl": "* 🐛 Opgeloste fouten**\n\n**Beheer van PV-overschotten en optimalisatie van de cyclus: **\n**Zero-Drift Baseline-berekening: ** De basislogica van de PV-boost herschreven in `PVManager.ts`. De adapter leest niet langer actuele datapuntstatussen om de boost te berekenen, maar handhaaft strikt de geconfigureerde basiswaarden (`sync_warmwater_target_temperature` en `0K` voor verwarming). Dit lost permanent het „sneeuwbaleffect” op, waarbij het doel voor warm water stapsgewijs tot de veiligheidsgrens van 70 °C zou kunnen dalen.\n**Cycle Coupling Handshake: ** Verbeterde de intelligente cyclusoptimalisatie (`main.ts`) tijdens een actief PV-overschot. Aan het einde van een verwarmingscyclus koppelt de adapter nu naadloos een warmwatercyclus en handhaaft op intelligente wijze de PV-boostdoelstelling (bijv. 60 °C) om het eigen verbruik van zonne-energie te maximaliseren, zonder de strikte basislogica te verstoren.",
|
|
90
|
-
"fr": "* 🐛 Bugcorrects**\n\n**Gestion du surplus PV et optimisation du cycle :**\n**Calcul de base à dérive nulle :** Réécriture de la logique de base du PV Boost dans « PVManager.ts ». L'adaptateur ne lit plus l'état des points de données en temps réel pour calculer le boost, mais applique strictement les valeurs de base configurées (sync_warmwater_target_temperature et 0 K pour le chauffage). Cela met fin définitivement à « l'effet boule de neige » où la température cible d'eau chaude peut atteindre la limite de sécurité de 70 °C.\n**Cycle Coupling Handshake :** Amélioration de l'optimisation intelligente des cycles (« main.ts ») en cas de surplus PV actif. À la fin d'un cycle de chauffage, l'adaptateur couple parfaitement un cycle d'eau chaude et applique intelligemment l'objectif de suralimentation (par exemple, 60 °C) afin de maximiser l'autoconsommation solaire, sans perturber la logique de base.",
|
|
91
|
-
"it": "* 🐛 Bugfix**\n\n**Gestione del surplus fotovoltaico e ciclo: **\n**Calcolo base Zero-Drift: ** Ha riscritto la logica di base PV boost in `PVManager.ts`. L'adattatore non legge più gli stati dei datapoint in tempo reale per calcolare il boost, ma applica rigorosamente i valori base configurati (sync_warmwater_target_temperature e 0K). Ciò risolve definitivamente l' «effetto valanga» in cui l'acqua calda target potrebbe spostarsi fino al limite di 70 °C.\n**Cycle Coupling Handshake: ** Ottimizzazione intelligente del ciclo (`main.ts`) durante il surplus fotovoltaico attivo. Alla fine di un ciclo di riscaldamento, l'adattatore ora abbina perfettamente un ciclo di acqua calda e impone il PV boost (ad es. 60 °C) per massimizzare l'autoconsumo solare, senza interferire con la logica di base.",
|
|
92
|
-
"es": "* 🐛 Correcciones**\n\n**Gestión de excedentes fotovoltaicos y optimización del ciclo: **\n**Cálculo de referencia sin deriva: ** Se reescribió la lógica base de PV Boost en «PVManager.ts». El adaptador ya no lee los estados de los puntos de datos en vivo para calcular el impulso, sino que aplica estrictamente los valores base configurados (sync_warmwater_target_temperature y 0 K para calefacción). Esto resuelve permanentemente el «efecto bola de nieve», en el que el objetivo de agua caliente podría llegar al límite de seguridad de 70°C.\n**Cycle Coupling Handshake: ** Se mejoró la optimización inteligente del ciclo (`main.ts`) durante el excedente fotovoltaico activo. Al final del ciclo de calefacción, el adaptador ahora conecta sin problemas un ciclo de agua caliente y aplica de forma inteligente el objetivo de aumento fotovoltaico (por ejemplo, 60 °C) para maximizar el autoconsumo solar, sin interferir con la estricta lógica básica.",
|
|
93
|
-
"pl": "* 🐛 Poprawki błędów**\n\n**Zarządzanie nadwyżką fotowoltaiczną i optymalizacja cyklu: **\n**Obliczanie linii bazowej zerowego dryfu: ** Przepisano logikę linii bazowej wzmocnienia PV w `PVManager.ts`. Adapter nie odczytuje już aktualnych stanów punktów danych w celu obliczenia wzmocnienia, ale ściśle egzekwuje skonfigurowane wartości bazowe („sync_warmwater_target_temperature” i „0K” dla ogrzewania). To trwale rozwiązuje „efekt kuli śnieżnej”, w którym cel gorącej wody może stopniowo dryfować do limitu bezpieczeństwa 70°C.\n**Cycle Coupling Handshake: ** Ulepszono inteligentną optymalizację cyklu („main.ts”) podczas aktywnej nadwyżki fotowoltaicznej. Pod koniec cyklu ogrzewania adapter bezproblemowo łączy cykl ciepłej wody i inteligentnie wymusza cel doładowania fotowoltaicznego (np. 60 °C), aby zmaksymalizować własne zużycie energii słonecznej, bez zakłócania ścisłej logiki bazowej.",
|
|
94
|
-
"uk": "* 🐛 Виправлення вадь**\n\n** Управління надлишком PV та оптимізація циклу: **\n**Обчислення базової лінії з нульовим дрейфом: ** Переписано логіку базової лінії збільшення PV у `PVManager.ts`. Адаптер більше не читає стани поточної точки даних для обчислення посилення, але суворо застосовує налаштовані базові значення (`sync_warmwater_target_temperature` та `0K` для нагрівання). Це назавжди усуває «ефект сніжної кулі», коли ціль гарячої води може поступово дрейфувати до межі безпеки 70°C.\n**Рукостискання циклу зчеплення: ** Покращено інтелектуальну оптимізацію циклу (`main.ts`) під час активного надлишку PV. Наприкінці циклу нагрівання адаптер тепер безперешкодно з'єднує цикл гарячої води та інтелектуально виконує ціль підвищення фотоелектричної енергії (наприклад, 60°C), щоб максимізувати власне споживання сонячної енергії, не втручаючись у сувору базову логіку.",
|
|
95
|
-
"zh-cn": "* 🐛 错误修复**\n\n**光伏盈余管理和周期优化:**\n**零漂移基线计算:** 在 `pvManager.ts` 中重写了光伏提升基线逻辑。适配器不再读取实时数据点状态来计算升压,而是严格执行配置的基准值(“sync_warmwater_target_temperuture” 和 “0K” 用于加热)。这永久解决了 “滚雪球效应”,即热水目标可能会逐渐漂移到70°C的安全极限。\n**循环耦合握手:** 增强了活跃光伏剩余期间的智能循环优化(`main.ts`)。在加热周期结束时,适配器现在可以无缝耦合热水循环,并智能地强制执行光伏升压目标(例如 60 °C),以最大限度地提高太阳能自消耗,而不会干扰严格的基准逻辑。"
|
|
96
96
|
}
|
|
97
97
|
},
|
|
98
98
|
"titleLang": {
|
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "iobroker.luxtronik2-controller",
|
|
3
|
-
"version": "0.25.
|
|
3
|
+
"version": "0.25.1",
|
|
4
4
|
"description": "Zugriff und Steuerung von Wärmepumpen mit einer Luxtronik 2.x Steuereinheit",
|
|
5
5
|
"author": {
|
|
6
6
|
"name": "TbsJah",
|
|
@@ -30,8 +30,7 @@
|
|
|
30
30
|
"dependencies": {
|
|
31
31
|
"@iobroker/adapter-core": "^3.4.3",
|
|
32
32
|
"modbus-serial": "^8.0.25",
|
|
33
|
-
"node-schedule": "^2.1.1"
|
|
34
|
-
"ws": "^8.22.0"
|
|
33
|
+
"node-schedule": "^2.1.1"
|
|
35
34
|
},
|
|
36
35
|
"devDependencies": {
|
|
37
36
|
"@alcalzone/release-script": "^5.2.1",
|