iobroker.luxtronik2-controller 0.19.4 → 0.20.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -0,0 +1,191 @@
1
+ "use strict";
2
+ var __create = Object.create;
3
+ var __defProp = Object.defineProperty;
4
+ var __getOwnPropDesc = Object.getOwnPropertyDescriptor;
5
+ var __getOwnPropNames = Object.getOwnPropertyNames;
6
+ var __getProtoOf = Object.getPrototypeOf;
7
+ var __hasOwnProp = Object.prototype.hasOwnProperty;
8
+ var __export = (target, all) => {
9
+ for (var name in all)
10
+ __defProp(target, name, { get: all[name], enumerable: true });
11
+ };
12
+ var __copyProps = (to, from, except, desc) => {
13
+ if (from && typeof from === "object" || typeof from === "function") {
14
+ for (let key of __getOwnPropNames(from))
15
+ if (!__hasOwnProp.call(to, key) && key !== except)
16
+ __defProp(to, key, { get: () => from[key], enumerable: !(desc = __getOwnPropDesc(from, key)) || desc.enumerable });
17
+ }
18
+ return to;
19
+ };
20
+ var __toESM = (mod, isNodeMode, target) => (target = mod != null ? __create(__getProtoOf(mod)) : {}, __copyProps(
21
+ // If the importer is in node compatibility mode or this is not an ESM
22
+ // file that has been converted to a CommonJS file using a Babel-
23
+ // compatible transform (i.e. "__esModule" has not been set), then set
24
+ // "default" to the CommonJS "module.exports" for node compatibility.
25
+ isNodeMode || !mod || !mod.__esModule ? __defProp(target, "default", { value: mod, enumerable: true }) : target,
26
+ mod
27
+ ));
28
+ var __toCommonJS = (mod) => __copyProps(__defProp({}, "__esModule", { value: true }), mod);
29
+ var updateManager_exports = {};
30
+ __export(updateManager_exports, {
31
+ checkFirmwareUpdate: () => checkFirmwareUpdate
32
+ });
33
+ module.exports = __toCommonJS(updateManager_exports);
34
+ var https = __toESM(require("node:https"));
35
+ var import_logger = require("./logger");
36
+ var import_notificationManager = require("./notificationManager");
37
+ var import_stateMapping = require("./stateMapping");
38
+ const DOWNLOAD_PORTAL_URL = "https://www.heatpump24.com/software/fetchSoftware.php?softwareID=";
39
+ const CHANGELOG_URL = "https://www.heatpump24.com/software/fetchSoftware.php?changeLog=";
40
+ const httpsAgent = new https.Agent({ rejectUnauthorized: false });
41
+ function getFirmwareDownloadId(installedVersion) {
42
+ if (!installedVersion) {
43
+ return null;
44
+ }
45
+ if (installedVersion.startsWith("V1.")) {
46
+ return 0;
47
+ }
48
+ if (installedVersion.startsWith("V2.")) {
49
+ return 1;
50
+ }
51
+ if (installedVersion.startsWith("V3.")) {
52
+ return 2;
53
+ }
54
+ if (installedVersion.startsWith("V4.")) {
55
+ return 3;
56
+ }
57
+ if (installedVersion.startsWith("F1.")) {
58
+ return 4;
59
+ }
60
+ if (installedVersion.startsWith("WWB1.")) {
61
+ return 5;
62
+ }
63
+ if (installedVersion.startsWith("smo")) {
64
+ return 6;
65
+ }
66
+ return null;
67
+ }
68
+ function isVersionNewer(availableVersion, currentVersion) {
69
+ const normalize = (v) => v.replace(/^[^\d]+/, "");
70
+ const v1Parts = normalize(availableVersion).split(".").map(Number);
71
+ const v2Parts = normalize(currentVersion).split(".").map(Number);
72
+ for (let i = 0; i < Math.max(v1Parts.length, v2Parts.length); i++) {
73
+ const part1 = v1Parts[i] || 0;
74
+ const part2 = v2Parts[i] || 0;
75
+ if (part1 > part2) {
76
+ return true;
77
+ }
78
+ if (part1 < part2) {
79
+ return false;
80
+ }
81
+ }
82
+ return false;
83
+ }
84
+ function fetchUrl(url, abortAfterHeaders = false, timeoutMs = 12e4) {
85
+ return new Promise((resolve, reject) => {
86
+ const options = {
87
+ method: "GET",
88
+ agent: httpsAgent,
89
+ timeout: timeoutMs,
90
+ // Dynamischer Timeout statt hart codiert
91
+ headers: {
92
+ "User-Agent": "ioBroker.luxtronik2-controller",
93
+ Accept: "*/*"
94
+ }
95
+ };
96
+ let wasAborted = false;
97
+ const req = https.request(url, options, (res) => {
98
+ if (abortAfterHeaders) {
99
+ wasAborted = true;
100
+ resolve({ headers: res.headers, data: "" });
101
+ req.destroy();
102
+ return;
103
+ }
104
+ let body = "";
105
+ res.on("data", (chunk) => body += chunk);
106
+ res.on("end", () => resolve({ headers: res.headers, data: body }));
107
+ });
108
+ req.on("error", (err) => {
109
+ if (!wasAborted) {
110
+ reject(err);
111
+ }
112
+ });
113
+ req.on("timeout", () => req.destroy(new Error("Timeout")));
114
+ req.end();
115
+ });
116
+ }
117
+ async function checkFirmwareUpdate(adapter) {
118
+ const config = adapter.config;
119
+ if (config.update_check_active !== true) {
120
+ return;
121
+ }
122
+ const timeoutSeconds = config.update_check_timeout ? Number(config.update_check_timeout) : 120;
123
+ const timeoutMs = timeoutSeconds * 1e3;
124
+ try {
125
+ const firmwareState = await adapter.getStateAsync((0, import_stateMapping.getDpPath)("firmware"));
126
+ const currentFirmware = firmwareState && typeof firmwareState.val === "string" ? firmwareState.val : null;
127
+ if (!currentFirmware) {
128
+ (0, import_logger.writeLog)("Update-Pr\xFCfung abgebrochen: Aktuelle Firmware-Version ist noch nicht bekannt.", "debug");
129
+ return;
130
+ }
131
+ const downloadId = getFirmwareDownloadId(currentFirmware);
132
+ if (downloadId === null) {
133
+ (0, import_logger.writeLog)(`Update-Pr\xFCfung abgebrochen: Unbekannter Firmware-Typ (${currentFirmware}).`, "debug");
134
+ return;
135
+ }
136
+ const response = await fetchUrl(`${DOWNLOAD_PORTAL_URL}${downloadId}`, true, timeoutMs);
137
+ const contentDisposition = response.headers["content-disposition"] || "";
138
+ const filenameMatch = contentDisposition.match(/filename=(.+)/);
139
+ if (!filenameMatch) {
140
+ (0, import_logger.writeLog)("Update-Pr\xFCfung: Konnte keinen Dateinamen im Download-Portal finden.", "debug");
141
+ return;
142
+ }
143
+ const filename = filenameMatch[1].replace(/"/g, "");
144
+ const versionMatch = filename.match(/[BV]\d+\.\d+\.\d+(?:-\d+)?/);
145
+ const availableVersion = versionMatch ? versionMatch[0].split("-")[0] : null;
146
+ if (!availableVersion) {
147
+ return;
148
+ }
149
+ await adapter.setState((0, import_stateMapping.getDpPath)("firmware_available"), { val: availableVersion, ack: true });
150
+ const isNewer = isVersionNewer(availableVersion, currentFirmware);
151
+ const updateStateDp = (0, import_stateMapping.getDpPath)("firmware_update_available");
152
+ const oldUpdateState = await adapter.getStateAsync(updateStateDp);
153
+ const wasAlreadyNotified = (oldUpdateState == null ? void 0 : oldUpdateState.val) === true;
154
+ await adapter.setState(updateStateDp, { val: isNewer, ack: true });
155
+ if (isNewer) {
156
+ const clResponse = await fetchUrl(`${CHANGELOG_URL}${downloadId}`, false, timeoutMs);
157
+ let cleanChangelog = "Kein Changelog verf\xFCgbar.";
158
+ if (clResponse.data) {
159
+ await adapter.setState((0, import_stateMapping.getDpPath)("firmware_changelog"), { val: clResponse.data, ack: true });
160
+ cleanChangelog = clResponse.data.replace(/<br\s*\/?>/gi, "\n").trim();
161
+ }
162
+ (0, import_logger.writeLog)(`Neues Firmware-Update verf\xFCgbar: ${availableVersion} (Aktuell: ${currentFirmware})`, "info");
163
+ if (!wasAlreadyNotified) {
164
+ (0, import_logger.writeLog)("Sende Benachrichtigungen \xFCber neues Firmware-Update...", "info");
165
+ await (0, import_notificationManager.sendUpdateNotification)(
166
+ adapter,
167
+ `Achtung: F\xFCr die W\xE4rmepumpe steht ein neues Firmware-Update bereit!
168
+
169
+ Aktuell: ${currentFirmware}
170
+ Neu: ${availableVersion}
171
+
172
+ Changelog:
173
+ ${cleanChangelog}
174
+
175
+ Bitte das Update manuell \xFCber den USB-Stick installieren.`
176
+ );
177
+ } else {
178
+ (0, import_logger.writeLog)("Benachrichtigung \xFCbersprungen (f\xFCr diese Version bereits erfolgt).", "debug");
179
+ }
180
+ } else {
181
+ (0, import_logger.writeLog)(`Firmware ist auf dem neuesten Stand (${currentFirmware}).`, "debug");
182
+ }
183
+ } catch (err) {
184
+ (0, import_logger.writeLog)(`Fehler bei der Firmware-Update-Pr\xFCfung: ${err.message}`, "error");
185
+ }
186
+ }
187
+ // Annotate the CommonJS export names for ESM import in node:
188
+ 0 && (module.exports = {
189
+ checkFirmwareUpdate
190
+ });
191
+ //# sourceMappingURL=updateManager.js.map
@@ -0,0 +1,7 @@
1
+ {
2
+ "version": 3,
3
+ "sources": ["../src/updateManager.ts"],
4
+ "sourcesContent": ["import * as https from 'node:https';\nimport { writeLog } from './logger';\nimport { sendUpdateNotification } from './notificationManager';\nimport { getDpPath } from './stateMapping';\nimport type { LuxtronikAdapter } from './types';\n\nconst DOWNLOAD_PORTAL_URL = 'https://www.heatpump24.com/software/fetchSoftware.php?softwareID=';\nconst CHANGELOG_URL = 'https://www.heatpump24.com/software/fetchSoftware.php?changeLog=';\n\n// Agent um unvollst\u00E4ndige Zertifikatsketten des AIT-Portals zu ignorieren\nconst httpsAgent = new https.Agent({ rejectUnauthorized: false });\n\n/**\n * Ermittelt die Download-ID f\u00FCr das Portal anhand der aktuellen Firmware.\n *\n * @param installedVersion Die aktuell auf der W\u00E4rmepumpe installierte Firmware-Version (z. B. \"V2.88.1\").\n * @returns Die ID f\u00FCr das Download-Portal oder null, falls das Format unbekannt ist.\n */\nfunction getFirmwareDownloadId(installedVersion: string): number | null {\n\tif (!installedVersion) {\n\t\treturn null;\n\t}\n\tif (installedVersion.startsWith('V1.')) {\n\t\treturn 0;\n\t}\n\tif (installedVersion.startsWith('V2.')) {\n\t\treturn 1;\n\t}\n\tif (installedVersion.startsWith('V3.')) {\n\t\treturn 2;\n\t}\n\tif (installedVersion.startsWith('V4.')) {\n\t\treturn 3;\n\t}\n\tif (installedVersion.startsWith('F1.')) {\n\t\treturn 4;\n\t}\n\tif (installedVersion.startsWith('WWB1.')) {\n\t\treturn 5;\n\t}\n\tif (installedVersion.startsWith('smo')) {\n\t\treturn 6;\n\t}\n\treturn null;\n}\n\n/**\n * Vergleicht zwei Versions-Strings (z. B. \"V2.88.1\" und \"V2.88.2\").\n *\n * @param availableVersion Die verf\u00FCgbare Version aus dem Download-Portal.\n * @param currentVersion Die aktuell installierte Version der W\u00E4rmepumpe.\n * @returns True, wenn die availableVersion neuer ist als die currentVersion.\n */\nfunction isVersionNewer(availableVersion: string, currentVersion: string): boolean {\n\tconst normalize = (v: string): string => v.replace(/^[^\\d]+/, ''); // \"V2.88.1\" -> \"2.88.1\"\n\tconst v1Parts = normalize(availableVersion).split('.').map(Number);\n\tconst v2Parts = normalize(currentVersion).split('.').map(Number);\n\n\tfor (let i = 0; i < Math.max(v1Parts.length, v2Parts.length); i++) {\n\t\tconst part1 = v1Parts[i] || 0;\n\t\tconst part2 = v2Parts[i] || 0;\n\t\tif (part1 > part2) {\n\t\t\treturn true;\n\t\t}\n\t\tif (part1 < part2) {\n\t\t\treturn false;\n\t\t}\n\t}\n\treturn false;\n}\n\n/**\n * Ruft eine URL per HTTP GET ab (ignoriert SSL-Fehler des AIT-Portals).\n *\n * @param url Die aufzurufende URL.\n * @param abortAfterHeaders Ob die Verbindung nach Empfang der Header direkt abgebrochen werden soll.\n * @param timeoutMs Timeout f\u00FCr die Anfrage in Millisekunden.\n * @returns Ein Promise mit den Headern und dem Body der Antwort.\n */\nfunction fetchUrl(url: string, abortAfterHeaders = false, timeoutMs = 120000): Promise<{ headers: any; data: string }> {\n\treturn new Promise((resolve, reject) => {\n\t\tconst options = {\n\t\t\tmethod: 'GET',\n\t\t\tagent: httpsAgent,\n\t\t\ttimeout: timeoutMs, // Dynamischer Timeout statt hart codiert\n\t\t\theaders: {\n\t\t\t\t'User-Agent': 'ioBroker.luxtronik2-controller',\n\t\t\t\tAccept: '*/*',\n\t\t\t},\n\t\t};\n\n\t\tlet wasAborted = false;\n\n\t\tconst req = https.request(url, options, res => {\n\t\t\tif (abortAfterHeaders) {\n\t\t\t\twasAborted = true; // Markieren, dass wir den Abbruch selbst ausgel\u00F6st haben\n\t\t\t\tresolve({ headers: res.headers, data: '' });\n\t\t\t\treq.destroy();\n\t\t\t\treturn;\n\t\t\t}\n\n\t\t\tlet body = '';\n\t\t\tres.on('data', chunk => (body += chunk));\n\t\t\tres.on('end', () => resolve({ headers: res.headers, data: body }));\n\t\t});\n\n\t\treq.on('error', err => {\n\t\t\t// Ignoriere jegliche Netzwerk-Fehler, wenn wir den Abbruch selbst ausgel\u00F6st haben\n\t\t\tif (!wasAborted) {\n\t\t\t\treject(err);\n\t\t\t}\n\t\t});\n\t\treq.on('timeout', () => req.destroy(new Error('Timeout')));\n\t\treq.end();\n\t});\n}\n\n/**\n * F\u00FChrt die Firmware-Update-Pr\u00FCfung durch.\n *\n * @param adapter Die aktuelle Instanz des ioBroker Adapters.\n * @returns Ein Promise, das nach Abschluss der Pr\u00FCfung aufgel\u00F6st wird.\n */\nexport async function checkFirmwareUpdate(adapter: LuxtronikAdapter): Promise<void> {\n\tconst config = adapter.config as Record<string, any>;\n\n\tif (config.update_check_active !== true) {\n\t\treturn;\n\t}\n\n\t// Timeout aus der Konfig lesen (Standard 120 Sekunden)\n\tconst timeoutSeconds = config.update_check_timeout ? Number(config.update_check_timeout) : 120;\n\tconst timeoutMs = timeoutSeconds * 1000;\n\n\ttry {\n\t\tconst firmwareState = await adapter.getStateAsync(getDpPath('firmware'));\n\t\tconst currentFirmware = firmwareState && typeof firmwareState.val === 'string' ? firmwareState.val : null;\n\n\t\tif (!currentFirmware) {\n\t\t\twriteLog('Update-Pr\u00FCfung abgebrochen: Aktuelle Firmware-Version ist noch nicht bekannt.', 'debug');\n\t\t\treturn;\n\t\t}\n\n\t\tconst downloadId = getFirmwareDownloadId(currentFirmware);\n\t\tif (downloadId === null) {\n\t\t\twriteLog(`Update-Pr\u00FCfung abgebrochen: Unbekannter Firmware-Typ (${currentFirmware}).`, 'debug');\n\t\t\treturn;\n\t\t}\n\n\t\t// 1. Dateinamen aus den Headern der Download-URL abfragen\n\t\tconst response = await fetchUrl(`${DOWNLOAD_PORTAL_URL}${downloadId}`, true, timeoutMs);\n\t\tconst contentDisposition = response.headers['content-disposition'] || '';\n\n\t\tconst filenameMatch = contentDisposition.match(/filename=(.+)/);\n\t\tif (!filenameMatch) {\n\t\t\twriteLog('Update-Pr\u00FCfung: Konnte keinen Dateinamen im Download-Portal finden.', 'debug');\n\t\t\treturn;\n\t\t}\n\n\t\tconst filename = filenameMatch[1].replace(/\"/g, '');\n\t\tconst versionMatch = filename.match(/[BV]\\d+\\.\\d+\\.\\d+(?:-\\d+)?/);\n\t\tconst availableVersion = versionMatch ? versionMatch[0].split('-')[0] : null;\n\n\t\tif (!availableVersion) {\n\t\t\treturn;\n\t\t}\n\n\t\tawait adapter.setState(getDpPath('firmware_available'), { val: availableVersion, ack: true });\n\n\t\tconst isNewer = isVersionNewer(availableVersion, currentFirmware);\n\t\tconst updateStateDp = getDpPath('firmware_update_available');\n\t\tconst oldUpdateState = await adapter.getStateAsync(updateStateDp);\n\t\tconst wasAlreadyNotified = oldUpdateState?.val === true;\n\n\t\tawait adapter.setState(updateStateDp, { val: isNewer, ack: true });\n\n\t\tif (isNewer) {\n\t\t\t// 2. Changelog abfragen\n\t\t\tconst clResponse = await fetchUrl(`${CHANGELOG_URL}${downloadId}`, false, timeoutMs);\n\t\t\tlet cleanChangelog = 'Kein Changelog verf\u00FCgbar.';\n\n\t\t\tif (clResponse.data) {\n\t\t\t\tawait adapter.setState(getDpPath('firmware_changelog'), { val: clResponse.data, ack: true });\n\n\t\t\t\t// HTML-Zeilenumbr\u00FCche f\u00FCr die Text-Benachrichtigung in echte Zeilenumbr\u00FCche (\\n) umwandeln\n\t\t\t\tcleanChangelog = clResponse.data.replace(/<br\\s*\\/?>/gi, '\\n').trim();\n\t\t\t}\n\n\t\t\twriteLog(`Neues Firmware-Update verf\u00FCgbar: ${availableVersion} (Aktuell: ${currentFirmware})`, 'info');\n\n\t\t\tif (!wasAlreadyNotified) {\n\t\t\t\twriteLog('Sende Benachrichtigungen \u00FCber neues Firmware-Update...', 'info');\n\n\t\t\t\t// Changelog direkt mit in die Nachricht einbauen\n\t\t\t\tawait sendUpdateNotification(\n\t\t\t\t\tadapter,\n\t\t\t\t\t`Achtung: F\u00FCr die W\u00E4rmepumpe steht ein neues Firmware-Update bereit!\\n\\nAktuell: ${currentFirmware}\\nNeu: ${availableVersion}\\n\\nChangelog:\\n${cleanChangelog}\\n\\nBitte das Update manuell \u00FCber den USB-Stick installieren.`,\n\t\t\t\t);\n\t\t\t} else {\n\t\t\t\twriteLog('Benachrichtigung \u00FCbersprungen (f\u00FCr diese Version bereits erfolgt).', 'debug');\n\t\t\t}\n\t\t} else {\n\t\t\twriteLog(`Firmware ist auf dem neuesten Stand (${currentFirmware}).`, 'debug');\n\t\t}\n\t} catch (err: any) {\n\t\twriteLog(`Fehler bei der Firmware-Update-Pr\u00FCfung: ${err.message}`, 'error');\n\t}\n}\n"],
5
+ "mappings": ";;;;;;;;;;;;;;;;;;;;;;;;;;;;AAAA;AAAA;AAAA;AAAA;AAAA;AAAA,YAAuB;AACvB,oBAAyB;AACzB,iCAAuC;AACvC,0BAA0B;AAG1B,MAAM,sBAAsB;AAC5B,MAAM,gBAAgB;AAGtB,MAAM,aAAa,IAAI,MAAM,MAAM,EAAE,oBAAoB,MAAM,CAAC;AAQhE,SAAS,sBAAsB,kBAAyC;AACvE,MAAI,CAAC,kBAAkB;AACtB,WAAO;AAAA,EACR;AACA,MAAI,iBAAiB,WAAW,KAAK,GAAG;AACvC,WAAO;AAAA,EACR;AACA,MAAI,iBAAiB,WAAW,KAAK,GAAG;AACvC,WAAO;AAAA,EACR;AACA,MAAI,iBAAiB,WAAW,KAAK,GAAG;AACvC,WAAO;AAAA,EACR;AACA,MAAI,iBAAiB,WAAW,KAAK,GAAG;AACvC,WAAO;AAAA,EACR;AACA,MAAI,iBAAiB,WAAW,KAAK,GAAG;AACvC,WAAO;AAAA,EACR;AACA,MAAI,iBAAiB,WAAW,OAAO,GAAG;AACzC,WAAO;AAAA,EACR;AACA,MAAI,iBAAiB,WAAW,KAAK,GAAG;AACvC,WAAO;AAAA,EACR;AACA,SAAO;AACR;AASA,SAAS,eAAe,kBAA0B,gBAAiC;AAClF,QAAM,YAAY,CAAC,MAAsB,EAAE,QAAQ,WAAW,EAAE;AAChE,QAAM,UAAU,UAAU,gBAAgB,EAAE,MAAM,GAAG,EAAE,IAAI,MAAM;AACjE,QAAM,UAAU,UAAU,cAAc,EAAE,MAAM,GAAG,EAAE,IAAI,MAAM;AAE/D,WAAS,IAAI,GAAG,IAAI,KAAK,IAAI,QAAQ,QAAQ,QAAQ,MAAM,GAAG,KAAK;AAClE,UAAM,QAAQ,QAAQ,CAAC,KAAK;AAC5B,UAAM,QAAQ,QAAQ,CAAC,KAAK;AAC5B,QAAI,QAAQ,OAAO;AAClB,aAAO;AAAA,IACR;AACA,QAAI,QAAQ,OAAO;AAClB,aAAO;AAAA,IACR;AAAA,EACD;AACA,SAAO;AACR;AAUA,SAAS,SAAS,KAAa,oBAAoB,OAAO,YAAY,MAAiD;AACtH,SAAO,IAAI,QAAQ,CAAC,SAAS,WAAW;AACvC,UAAM,UAAU;AAAA,MACf,QAAQ;AAAA,MACR,OAAO;AAAA,MACP,SAAS;AAAA;AAAA,MACT,SAAS;AAAA,QACR,cAAc;AAAA,QACd,QAAQ;AAAA,MACT;AAAA,IACD;AAEA,QAAI,aAAa;AAEjB,UAAM,MAAM,MAAM,QAAQ,KAAK,SAAS,SAAO;AAC9C,UAAI,mBAAmB;AACtB,qBAAa;AACb,gBAAQ,EAAE,SAAS,IAAI,SAAS,MAAM,GAAG,CAAC;AAC1C,YAAI,QAAQ;AACZ;AAAA,MACD;AAEA,UAAI,OAAO;AACX,UAAI,GAAG,QAAQ,WAAU,QAAQ,KAAM;AACvC,UAAI,GAAG,OAAO,MAAM,QAAQ,EAAE,SAAS,IAAI,SAAS,MAAM,KAAK,CAAC,CAAC;AAAA,IAClE,CAAC;AAED,QAAI,GAAG,SAAS,SAAO;AAEtB,UAAI,CAAC,YAAY;AAChB,eAAO,GAAG;AAAA,MACX;AAAA,IACD,CAAC;AACD,QAAI,GAAG,WAAW,MAAM,IAAI,QAAQ,IAAI,MAAM,SAAS,CAAC,CAAC;AACzD,QAAI,IAAI;AAAA,EACT,CAAC;AACF;AAQA,eAAsB,oBAAoB,SAA0C;AACnF,QAAM,SAAS,QAAQ;AAEvB,MAAI,OAAO,wBAAwB,MAAM;AACxC;AAAA,EACD;AAGA,QAAM,iBAAiB,OAAO,uBAAuB,OAAO,OAAO,oBAAoB,IAAI;AAC3F,QAAM,YAAY,iBAAiB;AAEnC,MAAI;AACH,UAAM,gBAAgB,MAAM,QAAQ,kBAAc,+BAAU,UAAU,CAAC;AACvE,UAAM,kBAAkB,iBAAiB,OAAO,cAAc,QAAQ,WAAW,cAAc,MAAM;AAErG,QAAI,CAAC,iBAAiB;AACrB,kCAAS,oFAAiF,OAAO;AACjG;AAAA,IACD;AAEA,UAAM,aAAa,sBAAsB,eAAe;AACxD,QAAI,eAAe,MAAM;AACxB,kCAAS,4DAAyD,eAAe,MAAM,OAAO;AAC9F;AAAA,IACD;AAGA,UAAM,WAAW,MAAM,SAAS,GAAG,mBAAmB,GAAG,UAAU,IAAI,MAAM,SAAS;AACtF,UAAM,qBAAqB,SAAS,QAAQ,qBAAqB,KAAK;AAEtE,UAAM,gBAAgB,mBAAmB,MAAM,eAAe;AAC9D,QAAI,CAAC,eAAe;AACnB,kCAAS,0EAAuE,OAAO;AACvF;AAAA,IACD;AAEA,UAAM,WAAW,cAAc,CAAC,EAAE,QAAQ,MAAM,EAAE;AAClD,UAAM,eAAe,SAAS,MAAM,4BAA4B;AAChE,UAAM,mBAAmB,eAAe,aAAa,CAAC,EAAE,MAAM,GAAG,EAAE,CAAC,IAAI;AAExE,QAAI,CAAC,kBAAkB;AACtB;AAAA,IACD;AAEA,UAAM,QAAQ,aAAS,+BAAU,oBAAoB,GAAG,EAAE,KAAK,kBAAkB,KAAK,KAAK,CAAC;AAE5F,UAAM,UAAU,eAAe,kBAAkB,eAAe;AAChE,UAAM,oBAAgB,+BAAU,2BAA2B;AAC3D,UAAM,iBAAiB,MAAM,QAAQ,cAAc,aAAa;AAChE,UAAM,sBAAqB,iDAAgB,SAAQ;AAEnD,UAAM,QAAQ,SAAS,eAAe,EAAE,KAAK,SAAS,KAAK,KAAK,CAAC;AAEjE,QAAI,SAAS;AAEZ,YAAM,aAAa,MAAM,SAAS,GAAG,aAAa,GAAG,UAAU,IAAI,OAAO,SAAS;AACnF,UAAI,iBAAiB;AAErB,UAAI,WAAW,MAAM;AACpB,cAAM,QAAQ,aAAS,+BAAU,oBAAoB,GAAG,EAAE,KAAK,WAAW,MAAM,KAAK,KAAK,CAAC;AAG3F,yBAAiB,WAAW,KAAK,QAAQ,gBAAgB,IAAI,EAAE,KAAK;AAAA,MACrE;AAEA,kCAAS,uCAAoC,gBAAgB,cAAc,eAAe,KAAK,MAAM;AAErG,UAAI,CAAC,oBAAoB;AACxB,oCAAS,6DAA0D,MAAM;AAGzE,kBAAM;AAAA,UACL;AAAA,UACA;AAAA;AAAA,WAAmF,eAAe;AAAA,OAAU,gBAAgB;AAAA;AAAA;AAAA,EAAmB,cAAc;AAAA;AAAA;AAAA,QAC9J;AAAA,MACD,OAAO;AACN,oCAAS,4EAAsE,OAAO;AAAA,MACvF;AAAA,IACD,OAAO;AACN,kCAAS,wCAAwC,eAAe,MAAM,OAAO;AAAA,IAC9E;AAAA,EACD,SAAS,KAAU;AAClB,gCAAS,8CAA2C,IAAI,OAAO,IAAI,OAAO;AAAA,EAC3E;AACD;",
6
+ "names": []
7
+ }
@@ -1,7 +1,7 @@
1
1
  {
2
2
  "version": 3,
3
3
  "sources": ["../src/zipManager.ts"],
4
- "sourcesContent": ["import { timeStringToSeconds } from './convert';\nimport { writeLog } from './logger';\nimport { queueWrite } from './rawFunctions';\nimport { getDpPath, STATE_MAPPING } from './stateMapping';\nimport type { LuxtronikAdapter } from './types';\n\n// =========================================================\n// CONSTANTS\n// =========================================================\n\nconst CONSTANTS = {\n\tCMD_DEAERATE: 158,\n\tCMD_ZIP: 684,\n\tMODBUS_COIL_ZIP: 7,\n\tEND_OF_DAY: 86340,\n\tWRITE_DELAY: 100,\n\tCOUNTDOWN_TICK_MS: 5000, // Update-Intervall f\u00FCr Restlaufzeit (5s schont DB)\n};\n\n// =========================================================\n// LEGACY STATE ID MAPPINGS\n// =========================================================\nconst LEGACY_DAYS = ['Sonntag', 'Montag', 'Dienstag', 'Mittwoch', 'Donnerstag', 'Freitag', 'Samstag'];\n\n// =========================================================\n// TYPES & INTERFACES\n// =========================================================\n\nexport type ZipConfig = Partial<Record<keyof typeof STATE_MAPPING, ioBroker.StateValue | null>>;\n\n// =========================================================\n// HELPER FUNCTIONS\n// =========================================================\n\n/**\n * Sch\u00FCtzt den Speicher durch Read-Before-Write direkt auf Rohwert-Ebene.\n *\n * @param adapter\n * @param key\n * @param luxId\n * @param rawValue\n */\nasync function safeRawWrite(\n\tadapter: LuxtronikAdapter,\n\tkey: keyof typeof STATE_MAPPING,\n\tluxId: number,\n\trawValue: number,\n): Promise<void> {\n\tconst dpPath = getDpPath(key);\n\tif (!dpPath) {\n\t\treturn;\n\t}\n\n\tconst state = await adapter.getStateAsync(dpPath);\n\n\tif (state && state.val !== null) {\n\t\tlet currentRaw: number | null = null;\n\n\t\tif (typeof state.val === 'boolean') {\n\t\t\tcurrentRaw = state.val ? 1 : 0;\n\t\t} else if (typeof state.val === 'number') {\n\t\t\tcurrentRaw = state.val;\n\t\t} else if (typeof state.val === 'string') {\n\t\t\tcurrentRaw = timeStringToSeconds(state.val);\n\t\t}\n\n\t\tif (currentRaw === rawValue) {\n\t\t\tif (adapter.isDebugLogActive) {\n\t\t\t\twriteLog(`[SafeWrite] Value for '${key}' is already at target (${rawValue}). Write blocked!`, 'debug');\n\t\t\t}\n\t\t\treturn;\n\t\t}\n\t}\n\n\tif (adapter.isDebugLogActive) {\n\t\twriteLog(`[SafeWrite] Change detected. Writing ${rawValue} to register ${luxId} (${key})...`, 'debug');\n\t}\n\tawait queueWrite(adapter, luxId, rawValue);\n\n\tawait new Promise<void>(resolve => {\n\t\tadapter.setTimeout(resolve, CONSTANTS.WRITE_DELAY);\n\t});\n}\n\n/**\n * Stoppt sowohl den Haupt-Timeout als auch das Countdown-Intervall der ZIP.\n *\n * @param adapter\n */\nfunction clearZipTimer(adapter: LuxtronikAdapter): void {\n\tif (adapter.zipTimer) {\n\t\tadapter.clearTimeout(adapter.zipTimer);\n\t\tadapter.zipTimer = undefined;\n\t}\n\tif (adapter.zipCountdownInterval) {\n\t\tadapter.clearInterval(adapter.zipCountdownInterval);\n\t\tadapter.zipCountdownInterval = undefined;\n\t}\n\tadapter.zipEndTime = undefined;\n}\n\n/**\n * Startet bzw. verl\u00E4ngert den Haupt-Timer und den sichtbaren Restlaufzeit-Countdown.\n *\n * @param adapter\n * @param durationSeconds\n * @param onTimeoutCallback\n */\nasync function startZipTimerAndCountdown(\n\tadapter: LuxtronikAdapter,\n\tdurationSeconds: number,\n\tonTimeoutCallback: () => Promise<void>,\n): Promise<void> {\n\tclearZipTimer(adapter);\n\n\tadapter.zipEndTime = Date.now() + durationSeconds * 1000;\n\n\tconst remainingDp = getDpPath('Virtual_ZIP_Remaining_Time');\n\tif (remainingDp) {\n\t\tawait adapter.setStateChangedAsync(remainingDp, { val: durationSeconds, ack: true });\n\t}\n\n\t// Zyklisches Update der Restlaufzeit\n\tadapter.zipCountdownInterval = adapter.setInterval(async () => {\n\t\tif (!adapter.zipEndTime) {\n\t\t\treturn;\n\t\t}\n\t\tconst remaining = Math.max(0, Math.round((adapter.zipEndTime - Date.now()) / 1000));\n\t\tif (remainingDp) {\n\t\t\tawait adapter.setStateChangedAsync(remainingDp, { val: remaining, ack: true });\n\t\t}\n\t}, CONSTANTS.COUNTDOWN_TICK_MS);\n\n\t// Haupt-Timer zum Ausschalten nach Ablauf\n\tadapter.zipTimer = adapter.setTimeout(async () => {\n\t\tclearZipTimer(adapter);\n\t\tif (remainingDp) {\n\t\t\tawait adapter.setStateChangedAsync(remainingDp, { val: 0, ack: true });\n\t\t}\n\t\tawait onTimeoutCallback();\n\t}, durationSeconds * 1000);\n}\n\n/**\n * Dynamically checks whether the current time is enabled for circulation according to the Luxtronik schedules.\n *\n * @param adapter\n */\nasync function isZipAllowedBySchedule(adapter: LuxtronikAdapter): Promise<boolean> {\n\tconst config = adapter.config;\n\n\t// Bei Modbus oder deaktivierten Hardware-Timern immer freigeben\n\tif (config.zip_control_mode === 'modbus' || config.zip_lWP_aktiv === true) {\n\t\treturn true;\n\t}\n\n\ttry {\n\t\tconst tableState = await adapter.getStateAsync(getDpPath('hotWaterCircPumpTimerTableSelected'));\n\t\tconst tableMode = tableState ? Number(tableState.val) : 0;\n\n\t\tconst now = new Date();\n\t\tconst day = now.getDay();\n\t\tconst currentSeconds = now.getHours() * 3600 + now.getMinutes() * 60 + now.getSeconds();\n\n\t\tlet prefix = 'Zirkulation_MoSo';\n\t\tlet endSuffix = 'End';\n\n\t\tif (tableMode === 1) {\n\t\t\tprefix = day >= 1 && day <= 5 ? 'Zirkulation_MoFr' : 'Zirkulation_SaSo';\n\t\t\tendSuffix = 'Ende';\n\t\t} else if (tableMode === 2) {\n\t\t\tprefix = `Zirkulation_${LEGACY_DAYS[day]}`;\n\t\t\tendSuffix = 'Ende';\n\t\t}\n\n\t\tlet isAllowed = false;\n\n\t\tfor (let i = 1; i <= 5; i++) {\n\t\t\tconst startKey = `${prefix}_Start${i}`;\n\t\t\tconst endKey = `${prefix}_${endSuffix}${i}`;\n\n\t\t\tconst startState = await adapter.getStateAsync(getDpPath(startKey));\n\t\t\tconst endState = await adapter.getStateAsync(getDpPath(endKey));\n\n\t\t\tif (startState && startState.val && endState && endState.val) {\n\t\t\t\tconst startSec = timeStringToSeconds(String(startState.val));\n\t\t\t\tconst endSec = timeStringToSeconds(String(endState.val));\n\n\t\t\t\tif (startSec !== endSec) {\n\t\t\t\t\tlet actualEndSec = endSec;\n\t\t\t\t\tif (endSec === 0 && startSec > 0) {\n\t\t\t\t\t\tactualEndSec = 86400; // Midnight\n\t\t\t\t\t}\n\t\t\t\t\tif (currentSeconds >= startSec && currentSeconds <= actualEndSec) {\n\t\t\t\t\t\tisAllowed = true;\n\t\t\t\t\t\tbreak;\n\t\t\t\t\t}\n\t\t\t\t}\n\t\t\t}\n\t\t}\n\t\treturn isAllowed;\n\t} catch (err: unknown) {\n\t\tconst msg = err instanceof Error ? err.message : String(err);\n\t\tif (adapter.isDebugLogActive) {\n\t\t\twriteLog(`[ZIP] Error during schedule check: ${msg}`, 'error');\n\t\t}\n\t\treturn true;\n\t}\n}\n\n// =========================================================\n// MAIN EXPORTS\n// =========================================================\n\n/**\n * Restores the original circulation pump configuration from the saved cache.\n *\n * @param adapter\n */\nexport async function restoreOriginalZipConfig(adapter: LuxtronikAdapter): Promise<void> {\n\tif (!adapter.originalZipConfig) {\n\t\treturn;\n\t}\n\n\ttry {\n\t\tfor (const [key, val] of Object.entries(adapter.originalZipConfig)) {\n\t\t\tif (val === null || val === undefined) {\n\t\t\t\tcontinue;\n\t\t\t}\n\n\t\t\tconst def = STATE_MAPPING[key];\n\t\t\tif (!def || !def.luxWriteId) {\n\t\t\t\tcontinue;\n\t\t\t}\n\n\t\t\tlet rawVal = val;\n\n\t\t\tif (def.role === 'value.datetime' && typeof val === 'string') {\n\t\t\t\trawVal = timeStringToSeconds(val);\n\t\t\t}\n\n\t\t\tconst targetPath = getDpPath(key);\n\t\t\tif (targetPath) {\n\t\t\t\tawait adapter.setState(targetPath, { val: val, ack: true });\n\t\t\t}\n\n\t\t\tconst luxId = Number(def.luxWriteId);\n\t\t\tif (!isNaN(luxId)) {\n\t\t\t\tawait queueWrite(adapter, luxId, Number(rawVal));\n\t\t\t\tawait new Promise<void>(resolve => {\n\t\t\t\t\tadapter.setTimeout(() => resolve(), CONSTANTS.WRITE_DELAY);\n\t\t\t\t});\n\t\t\t}\n\t\t}\n\t} catch (err: unknown) {\n\t\tconst msg = err instanceof Error ? err.message : String(err);\n\t\twriteLog(`Error restoring ZIP configuration: ${msg}`, 'error');\n\t} finally {\n\t\tadapter.originalZipConfig = null;\n\t}\n}\n\n/**\n * Stops the active circulation pump macro and deaeration program across all modes.\n *\n * @param adapter\n */\nexport async function stopZipAndDeaeration(adapter: LuxtronikAdapter): Promise<void> {\n\tconst mode = adapter.config.zip_control_mode || 'controller';\n\tconst actors = adapter.config.actors || [];\n\tconst validActors = actors.filter((a: any) => a.zip_external_relay_id && a.zip_external_relay_id.trim() !== '');\n\n\tclearZipTimer(adapter);\n\n\t// 1. Externe Aktoren abschalten (falls Modus = 'actor' oder als Fallback konfiguriert)\n\tif (mode === 'actor' || validActors.length > 0) {\n\t\ttry {\n\t\t\tfor (const actor of validActors) {\n\t\t\t\tawait adapter.setForeignStateAsync(actor.zip_external_relay_id, false, false);\n\t\t\t}\n\t\t\tif (adapter.isDebugLogActive && validActors.length > 0) {\n\t\t\t\twriteLog(`[ZIP] Emergency/Timeout stop sent for external relays.`, 'debug');\n\t\t\t}\n\t\t} catch (err: unknown) {\n\t\t\tconst msg = err instanceof Error ? err.message : String(err);\n\t\t\twriteLog(`[ZIP] Error switching off external relays: ${msg}`, 'error');\n\t\t}\n\t}\n\n\t// 2. Modbus Coil 7 abschalten (falls Modus = 'modbus')\n\tif (mode === 'modbus') {\n\t\ttry {\n\t\t\tif (adapter.modbusManager && adapter.modbusManager.isAvailable) {\n\t\t\t\tawait adapter.modbusManager.writeRegister(CONSTANTS.MODBUS_COIL_ZIP, 0, true);\n\t\t\t\tif (adapter.isDebugLogActive) {\n\t\t\t\t\twriteLog(`[ZIP] Modbus Coil ${CONSTANTS.MODBUS_COIL_ZIP} switched OFF.`, 'debug');\n\t\t\t\t}\n\t\t\t}\n\t\t} catch (err: unknown) {\n\t\t\tconst msg = err instanceof Error ? err.message : String(err);\n\t\t\twriteLog(`[ZIP] Error switching off Modbus Coil 7: ${msg}`, 'error');\n\t\t}\n\t}\n\n\t// 3. Internen Luxtronik-Regler zur\u00FCcksetzen (falls Modus = 'controller' oder noch ein altes Makro lief)\n\ttry {\n\t\tconst activateZipState = await adapter.getStateAsync(getDpPath('Activate_Zip'));\n\t\tconst runDeaerateState = await adapter.getStateAsync(getDpPath('runDeaerate'));\n\n\t\tconst isZipActive = activateZipState?.val === true || adapter.originalZipConfig !== null;\n\t\tconst isDeaerateActive = runDeaerateState?.val === 1 || runDeaerateState?.val === true;\n\n\t\tif (mode === 'controller' && (isZipActive || isDeaerateActive)) {\n\t\t\tif (adapter.isDebugLogActive) {\n\t\t\t\twriteLog('Stopping active controller ZIP macro and deaeration program...', 'info');\n\t\t\t}\n\n\t\t\tawait restoreOriginalZipConfig(adapter);\n\n\t\t\tawait safeRawWrite(adapter, 'runDeaerate', CONSTANTS.CMD_DEAERATE, 0);\n\t\t\tawait safeRawWrite(adapter, 'hotWaterCircPumpDeaerate', CONSTANTS.CMD_ZIP, 0);\n\n\t\t\tconst dpDeaerate = getDpPath('runDeaerate');\n\t\t\tconst dpCircDeaerate = getDpPath('hotWaterCircPumpDeaerate');\n\t\t\tif (dpDeaerate) {\n\t\t\t\tawait adapter.setOwnStateIfDifferent(dpDeaerate, false, true);\n\t\t\t}\n\t\t\tif (dpCircDeaerate) {\n\t\t\t\tawait adapter.setOwnStateIfDifferent(dpCircDeaerate, false, true);\n\t\t\t}\n\t\t}\n\n\t\tconst dpZip = getDpPath('Activate_Zip');\n\t\tif (dpZip) {\n\t\t\tawait adapter.setOwnStateIfDifferent(dpZip, false, true);\n\t\t}\n\t} catch (err: unknown) {\n\t\tconst msg = err instanceof Error ? err.message : String(err);\n\t\twriteLog(`Error stopping ZIP/Deaeration: ${msg}`, 'error');\n\t} finally {\n\t\t// GARANTIERTER RESET: Virtueller Status und Restlaufzeit immer auf AUS / 0 setzen\n\t\tconst virtualDp = getDpPath('Virtual_ZIP_Status');\n\t\tif (virtualDp) {\n\t\t\tawait adapter.setStateChangedAsync(virtualDp, { val: false, ack: true });\n\t\t}\n\t\tconst remainingDp = getDpPath('Virtual_ZIP_Remaining_Time');\n\t\tif (remainingDp) {\n\t\t\tawait adapter.setStateChangedAsync(remainingDp, { val: 0, ack: true });\n\t\t}\n\t}\n}\n\n/**\n * Activates the circulation pump (ZIP) via the selected control mode for a specified duration.\n *\n * @param adapter\n * @param id\n * @param durationSeconds\n */\nexport async function handleActivateZip(adapter: LuxtronikAdapter, id: string, durationSeconds: number): Promise<void> {\n\tconst mode = adapter.config.zip_control_mode || 'controller';\n\tconst actors = adapter.config.actors || [];\n\tconst validActors = actors.filter((a: any) => a.zip_external_relay_id && a.zip_external_relay_id.trim() !== '');\n\n\tconst localId = id.replace(`${adapter.namespace}.`, '');\n\tawait adapter.setState(localId, { val: true, ack: true });\n\n\tif (durationSeconds <= 0) {\n\t\tawait stopZipAndDeaeration(adapter);\n\t\treturn;\n\t}\n\n\tconst safeDurationSeconds = Math.max(1, isNaN(durationSeconds) ? 60 : durationSeconds);\n\n\t// Pr\u00FCfen, ob die Pumpe bereits \u00FCber unseren Adapter-Timer l\u00E4uft\n\tconst virtualStatusState = await adapter.getStateAsync(getDpPath('Virtual_ZIP_Status'));\n\tconst isZipAlreadyRunning = Boolean(adapter.zipTimer) || virtualStatusState?.val === true;\n\n\tif (isZipAlreadyRunning) {\n\t\tif (adapter.isDebugLogActive) {\n\t\t\twriteLog(\n\t\t\t\t`[ZIP] Pump is already running (Mode: ${mode}). Extending timer to ${safeDurationSeconds}s.`,\n\t\t\t\t'debug',\n\t\t\t);\n\t\t}\n\t\tawait startZipTimerAndCountdown(adapter, safeDurationSeconds, async () => {\n\t\t\tawait stopZipAndDeaeration(adapter);\n\t\t});\n\t\treturn;\n\t}\n\n\t// =========================================================\n\t// WEICHE 1: EXTERNER AKTOR (z.B. Shelly)\n\t// =========================================================\n\tif (mode === 'actor') {\n\t\tif (validActors.length === 0) {\n\t\t\twriteLog('[ZIP] Mode is set to external actor, but no valid actor OIDs are configured!', 'warn');\n\t\t\tawait adapter.setState(localId, { val: false, ack: true });\n\t\t\treturn;\n\t\t}\n\n\t\tif (adapter.isDebugLogActive) {\n\t\t\twriteLog(`[ZIP] Switching ON ${validActors.length} external actor(s) for ${safeDurationSeconds}s`, 'debug');\n\t\t}\n\n\t\tfor (const actor of validActors) {\n\t\t\ttry {\n\t\t\t\tawait adapter.setForeignStateAsync(actor.zip_external_relay_id, true, false);\n\t\t\t} catch (err) {\n\t\t\t\tconst msg = err instanceof Error ? err.message : String(err);\n\t\t\t\twriteLog(`[ZIP] Error switching on ${actor.zip_external_relay_id}: ${msg}`, 'error');\n\t\t\t}\n\t\t}\n\n\t\tconst virtualDp = getDpPath('Virtual_ZIP_Status');\n\t\tif (virtualDp) {\n\t\t\tawait adapter.setStateChangedAsync(virtualDp, { val: true, ack: true });\n\t\t}\n\n\t\tawait startZipTimerAndCountdown(adapter, safeDurationSeconds, async () => {\n\t\t\tawait stopZipAndDeaeration(adapter);\n\t\t});\n\t\treturn;\n\t}\n\n\t// =========================================================\n\t// WEICHE 2: MODBUS TCP (Coil 7)\n\t// =========================================================\n\tif (mode === 'modbus') {\n\t\tif (!adapter.modbusManager || !adapter.modbusManager.isAvailable) {\n\t\t\twriteLog('[ZIP] Mode is set to Modbus TCP, but Modbus is disabled or unreachable!', 'warn');\n\t\t\tawait adapter.setState(localId, { val: false, ack: true });\n\t\t\treturn;\n\t\t}\n\n\t\tif (adapter.isDebugLogActive) {\n\t\t\twriteLog(\n\t\t\t\t`[ZIP] Switching ON via Modbus Coil ${CONSTANTS.MODBUS_COIL_ZIP} for ${safeDurationSeconds}s`,\n\t\t\t\t'debug',\n\t\t\t);\n\t\t}\n\n\t\tawait adapter.modbusManager.writeRegister(CONSTANTS.MODBUS_COIL_ZIP, 1, true);\n\n\t\tconst virtualDp = getDpPath('Virtual_ZIP_Status');\n\t\tif (virtualDp) {\n\t\t\tawait adapter.setStateChangedAsync(virtualDp, { val: true, ack: true });\n\t\t}\n\n\t\tawait startZipTimerAndCountdown(adapter, safeDurationSeconds, async () => {\n\t\t\tawait stopZipAndDeaeration(adapter);\n\t\t});\n\t\treturn;\n\t}\n\n\t// =========================================================\n\t// WEICHE 3: INTERNER LUXTRONIK REGLER (Standard)\n\t// =========================================================\n\tconst bzState = await adapter.getStateAsync(getDpPath('WP_BZ_akt'));\n\tconst bzVal = bzState ? Number(bzState.val) : 5;\n\n\tconst [wwIstS, wwSollS, wwHystS, rLState, rSollState, hzHystState] = await Promise.all([\n\t\tadapter.getStateAsync(getDpPath('Wamwassertemperatur_Ist')),\n\t\tadapter.getStateAsync(getDpPath('Wamwassertemperatur_Soll')),\n\t\tadapter.getStateAsync(getDpPath('hotWaterTemperatureHysteresis')),\n\t\tadapter.getStateAsync(getDpPath('temperature_return')),\n\t\tadapter.getStateAsync(getDpPath('temperature_target_return')),\n\t\tadapter.getStateAsync(getDpPath('returnTemperatureHysteresis')),\n\t]);\n\n\tconst useDeaeration =\n\t\tbzVal === 5 &&\n\t\tNumber(wwIstS?.val) > Number(wwSollS?.val) - Number(wwHystS?.val) &&\n\t\tNumber(rLState?.val) > Number(rSollState?.val) - Number(hzHystState?.val);\n\n\tif (useDeaeration) {\n\t\tawait safeRawWrite(adapter, 'runDeaerate', CONSTANTS.CMD_DEAERATE, 1);\n\t\tawait safeRawWrite(adapter, 'hotWaterCircPumpDeaerate', CONSTANTS.CMD_ZIP, 1);\n\n\t\tconst dpDeaerate = getDpPath('runDeaerate');\n\t\tconst dpCircDeaerate = getDpPath('hotWaterCircPumpDeaerate');\n\t\tif (dpDeaerate) {\n\t\t\tawait adapter.setOwnStateIfDifferent(dpDeaerate, true, true);\n\t\t}\n\t\tif (dpCircDeaerate) {\n\t\t\tawait adapter.setOwnStateIfDifferent(dpCircDeaerate, true, true);\n\t\t}\n\t} else {\n\t\tconst onTimeMinutes = Math.ceil(safeDurationSeconds / 60);\n\t\tif (!adapter.originalZipConfig) {\n\t\t\tconst keysToSave = [\n\t\t\t\t'hotWaterCircPumpTimerTableSelected',\n\t\t\t\t'WW_MoSo_Start1',\n\t\t\t\t'WW_MoSo_End1',\n\t\t\t\t'WW_MoSo_Start2',\n\t\t\t\t'WW_MoSo_End2',\n\t\t\t\t'WW_MoSo_Start3',\n\t\t\t\t'WW_MoSo_End3',\n\t\t\t\t'WW_MoSo_Start4',\n\t\t\t\t'WW_MoSo_End4',\n\t\t\t\t'WW_MoSo_Start5',\n\t\t\t\t'WW_MoSo_End5',\n\t\t\t\t'hotWaterCircPumpOnTime',\n\t\t\t\t'hotWaterCircPumpOffTime',\n\t\t\t] as const;\n\n\t\t\tconst states = await Promise.all(keysToSave.map(key => adapter.getStateAsync(getDpPath(key as any))));\n\n\t\t\tadapter.originalZipConfig = {};\n\t\t\tkeysToSave.forEach((key, index) => {\n\t\t\t\tif (adapter.originalZipConfig) {\n\t\t\t\t\tadapter.originalZipConfig[key] = states[index] ? states[index].val : null;\n\t\t\t\t}\n\t\t\t});\n\t\t}\n\n\t\tconst updates = [\n\t\t\t{ key: 'hotWaterCircPumpTimerTableSelected', raw: 0 },\n\t\t\t{ key: 'WW_MoSo_Start1', raw: 0 },\n\t\t\t{ key: 'WW_MoSo_End1', raw: CONSTANTS.END_OF_DAY },\n\t\t\t{ key: 'WW_MoSo_Start2', raw: 0 },\n\t\t\t{ key: 'WW_MoSo_End2', raw: 0 },\n\t\t\t{ key: 'hotWaterCircPumpOnTime', raw: onTimeMinutes },\n\t\t\t{ key: 'hotWaterCircPumpOffTime', raw: 60 },\n\t\t] as const;\n\n\t\tfor (const u of updates) {\n\t\t\tconst def = STATE_MAPPING[u.key];\n\t\t\tif (def && def.luxWriteId) {\n\t\t\t\tawait safeRawWrite(adapter, u.key, parseInt(def.luxWriteId, 10), u.raw);\n\t\t\t}\n\t\t}\n\t}\n\n\tconst virtualDp = getDpPath('Virtual_ZIP_Status');\n\tif (virtualDp) {\n\t\tawait adapter.setStateChangedAsync(virtualDp, { val: true, ack: true });\n\t}\n\n\tawait startZipTimerAndCountdown(adapter, safeDurationSeconds, async () => {\n\t\tawait stopZipAndDeaeration(adapter);\n\t});\n}\n\n/**\n * Abonniert die in der Konfiguration hinterlegten Bewegungsmelder (Foreign States).\n *\n * @param adapter\n */\nexport function subscribeMotionSensors(adapter: LuxtronikAdapter): void {\n\tconst config = adapter.config;\n\tif (config.motion_sensors_aktiv && Array.isArray(config.motionSensors)) {\n\t\tfor (const sensor of config.motionSensors) {\n\t\t\tif (sensor.oid && typeof sensor.oid === 'string' && sensor.oid.trim() !== '') {\n\t\t\t\tadapter.subscribeForeignStates(sensor.oid.trim());\n\t\t\t\tif (adapter.isDebugLogActive) {\n\t\t\t\t\twriteLog(`Motion sensor subscribed: ${sensor.name} (${sensor.oid})`, 'info');\n\t\t\t\t}\n\t\t\t}\n\t\t}\n\t}\n}\n\n/**\n * Pr\u00FCft bei einem StateChange, ob ein abonnierter Bewegungsmelder ausgel\u00F6st hat.\n *\n * @param adapter\n * @param id\n * @param state\n */\nexport async function checkAndHandleMotionSensor(\n\tadapter: LuxtronikAdapter,\n\tid: string,\n\tstate: ioBroker.State,\n): Promise<boolean> {\n\tconst config = adapter.config;\n\n\tif (!config.motion_sensors_aktiv || !config.motionSensors || !Array.isArray(config.motionSensors)) {\n\t\treturn false;\n\t}\n\n\tconst matchedSensor = config.motionSensors.find((s: any) => s.oid && s.oid.trim() === id);\n\tif (!matchedSensor) {\n\t\treturn false;\n\t}\n\n\tif (state.val === true) {\n\t\tif (!state.ack) {\n\t\t\treturn false;\n\t\t}\n\t\tconst isAllowedBySchedule = await isZipAllowedBySchedule(adapter);\n\n\t\tif (!isAllowedBySchedule) {\n\t\t\tif (adapter.isDebugLogActive) {\n\t\t\t\twriteLog(\n\t\t\t\t\t`Motion registered at sensor '${matchedSensor.name || id}', but action ignored because it is outside the configured Luxtronik ZIP schedule.`,\n\t\t\t\t\t'debug',\n\t\t\t\t);\n\t\t\t}\n\t\t\treturn true;\n\t\t}\n\n\t\tconst activateZipState = await adapter.getStateAsync(getDpPath('Activate_Zip'));\n\t\tconst now = Date.now();\n\t\tconst lastZipChange = activateZipState?.lc || 0;\n\t\tconst isCurrentlyActive = activateZipState?.val === true;\n\n\t\tif (isCurrentlyActive || now - lastZipChange > (config.zip_last_run_min || 600) * 1000) {\n\t\t\tif (adapter.isDebugLogActive) {\n\t\t\t\twriteLog(\n\t\t\t\t\t`Motion registered at sensor '${matchedSensor.name || id}'. Launching or extending circulation pump ZIP macro sequence.`,\n\t\t\t\t\t'debug',\n\t\t\t\t);\n\t\t\t}\n\t\t\tawait adapter.setState(getDpPath('Activate_Zip'), { val: true, ack: false });\n\t\t} else {\n\t\t\tif (adapter.isDebugLogActive) {\n\t\t\t\twriteLog(\n\t\t\t\t\t`Motion registered at sensor '${matchedSensor.name || id}' but circulation pump execution suppressed due to anti-cycling protective interval timer.`,\n\t\t\t\t\t'debug',\n\t\t\t\t);\n\t\t\t}\n\t\t}\n\t}\n\n\treturn true;\n}\n\n/**\n * Deaktiviert die regul\u00E4ren Hardware-Timer der Zirkulationspumpe beim Adapter-Start.\n *\n * @param adapter\n */\nexport async function disableHardwareZipTimer(adapter: LuxtronikAdapter): Promise<void> {\n\tconst config = adapter.config;\n\n\t// Bei Modbus-Steuerung m\u00FCssen wir die internen Timer nicht anfassen\n\tif (config.zip_control_mode === 'modbus') {\n\t\treturn;\n\t}\n\n\tif (config.zip_lWP_aktiv === true) {\n\t\tif (adapter.isDebugLogActive) {\n\t\t\twriteLog('Applying safe hardware defaults for ZIP timers...', 'info');\n\t\t}\n\n\t\ttry {\n\t\t\tawait safeRawWrite(adapter, 'hotWaterCircPumpTimerTableSelected', 506, 0);\n\t\t\tawait adapter.setOwnStateIfDifferent(getDpPath('hotWaterCircPumpTimerTableSelected'), 0, true);\n\n\t\t\tawait safeRawWrite(adapter, 'hotWaterCircPumpOnTime', 697, 0);\n\t\t\tawait adapter.setOwnStateIfDifferent(getDpPath('hotWaterCircPumpOnTime'), 0, true);\n\n\t\t\tawait safeRawWrite(adapter, 'hotWaterCircPumpOffTime', 698, 60);\n\t\t\tawait adapter.setOwnStateIfDifferent(getDpPath('hotWaterCircPumpOffTime'), 60, true);\n\n\t\t\tconst timeIds = [\n\t\t\t\t{ key: 'Zirkulation_MoSo_Start1', id: 507 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_End1', id: 508 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_Start2', id: 509 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_End2', id: 510 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_Start3', id: 511 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_End3', id: 512 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_Start4', id: 513 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_End4', id: 514 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_Start5', id: 515 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_End5', id: 516 },\n\t\t\t] as const;\n\n\t\t\tfor (const t of timeIds) {\n\t\t\t\tawait safeRawWrite(adapter, t.key, t.id, 0);\n\t\t\t\tawait adapter.setOwnStateIfDifferent(getDpPath(t.key), '00:00', true);\n\t\t\t}\n\t\t} catch (err: unknown) {\n\t\t\tconst msg = err instanceof Error ? err.message : String(err);\n\t\t\twriteLog(`Error applying safe ZIP defaults: ${msg}`, 'error');\n\t\t}\n\t}\n}\n"],
4
+ "sourcesContent": ["import { timeStringToSeconds } from './convert';\nimport { writeLog } from './logger';\nimport { queueWrite } from './rawFunctions';\nimport { getDpPath, STATE_MAPPING } from './stateMapping';\nimport type { LuxtronikAdapter } from './types';\n\n// =========================================================\n// CONSTANTS\n// =========================================================\n\nconst CONSTANTS = {\n\tCMD_DEAERATE: 158,\n\tCMD_ZIP: 684,\n\tMODBUS_COIL_ZIP: 7,\n\tEND_OF_DAY: 86340,\n\tWRITE_DELAY: 100,\n\tCOUNTDOWN_TICK_MS: 5000, // Update-Intervall f\u00FCr Restlaufzeit (5s schont DB)\n};\n\n// =========================================================\n// LEGACY STATE ID MAPPINGS\n// =========================================================\nconst LEGACY_DAYS = ['Sonntag', 'Montag', 'Dienstag', 'Mittwoch', 'Donnerstag', 'Freitag', 'Samstag'];\n\n// =========================================================\n// TYPES & INTERFACES\n// =========================================================\n\nexport type ZipConfig = Partial<Record<keyof typeof STATE_MAPPING, ioBroker.StateValue | null>>;\n\n// =========================================================\n// HELPER FUNCTIONS\n// =========================================================\n\n/**\n * Sch\u00FCtzt den Speicher durch Read-Before-Write direkt auf Rohwert-Ebene.\n *\n * @param adapter Die aktuelle Adapter-Instanz.\n * @param key Der betroffene Datenpunkt-Schl\u00FCssel.\n * @param luxId Die Luxtronik-ID.\n * @param rawValue Der rohe Messwert.\n */\nasync function safeRawWrite(\n\tadapter: LuxtronikAdapter,\n\tkey: keyof typeof STATE_MAPPING,\n\tluxId: number,\n\trawValue: number,\n): Promise<void> {\n\tconst dpPath = getDpPath(key);\n\tif (!dpPath) {\n\t\treturn;\n\t}\n\n\tconst state = await adapter.getStateAsync(dpPath);\n\n\tif (state && state.val !== null) {\n\t\tlet currentRaw: number | null = null;\n\n\t\tif (typeof state.val === 'boolean') {\n\t\t\tcurrentRaw = state.val ? 1 : 0;\n\t\t} else if (typeof state.val === 'number') {\n\t\t\tcurrentRaw = state.val;\n\t\t} else if (typeof state.val === 'string') {\n\t\t\tcurrentRaw = timeStringToSeconds(state.val);\n\t\t}\n\n\t\tif (currentRaw === rawValue) {\n\t\t\tif (adapter.isDebugLogActive) {\n\t\t\t\twriteLog(`[SafeWrite] Value for '${key}' is already at target (${rawValue}). Write blocked!`, 'debug');\n\t\t\t}\n\t\t\treturn;\n\t\t}\n\t}\n\n\tif (adapter.isDebugLogActive) {\n\t\twriteLog(`[SafeWrite] Change detected. Writing ${rawValue} to register ${luxId} (${key})...`, 'debug');\n\t}\n\tawait queueWrite(adapter, luxId, rawValue);\n\n\tawait new Promise<void>(resolve => {\n\t\tadapter.setTimeout(resolve, CONSTANTS.WRITE_DELAY);\n\t});\n}\n\n/**\n * Stoppt sowohl den Haupt-Timeout als auch das Countdown-Intervall der ZIP.\n *\n * @param adapter Die aktuelle Adapter-Instanz.\n */\nfunction clearZipTimer(adapter: LuxtronikAdapter): void {\n\tif (adapter.zipTimer) {\n\t\tadapter.clearTimeout(adapter.zipTimer);\n\t\tadapter.zipTimer = undefined;\n\t}\n\tif (adapter.zipCountdownInterval) {\n\t\tadapter.clearInterval(adapter.zipCountdownInterval);\n\t\tadapter.zipCountdownInterval = undefined;\n\t}\n\tadapter.zipEndTime = undefined;\n}\n\n/**\n * Startet bzw. verl\u00E4ngert den Haupt-Timer und den sichtbaren Restlaufzeit-Countdown.\n *\n * @param adapter Die aktuelle Adapter-Instanz.\n * @param durationSeconds Die Dauer in Sekunden.\n * @param onTimeoutCallback Callback wenn der Timer abl\u00E4uft.\n */\nasync function startZipTimerAndCountdown(\n\tadapter: LuxtronikAdapter,\n\tdurationSeconds: number,\n\tonTimeoutCallback: () => Promise<void>,\n): Promise<void> {\n\tclearZipTimer(adapter);\n\n\tadapter.zipEndTime = Date.now() + durationSeconds * 1000;\n\n\tconst remainingDp = getDpPath('Virtual_ZIP_Remaining_Time');\n\tif (remainingDp) {\n\t\tawait adapter.setStateChangedAsync(remainingDp, { val: durationSeconds, ack: true });\n\t}\n\n\t// Zyklisches Update der Restlaufzeit\n\tadapter.zipCountdownInterval = adapter.setInterval(async () => {\n\t\tif (!adapter.zipEndTime) {\n\t\t\treturn;\n\t\t}\n\t\tconst remaining = Math.max(0, Math.round((adapter.zipEndTime - Date.now()) / 1000));\n\t\tif (remainingDp) {\n\t\t\tawait adapter.setStateChangedAsync(remainingDp, { val: remaining, ack: true });\n\t\t}\n\t}, CONSTANTS.COUNTDOWN_TICK_MS);\n\n\t// Haupt-Timer zum Ausschalten nach Ablauf\n\tadapter.zipTimer = adapter.setTimeout(async () => {\n\t\tclearZipTimer(adapter);\n\t\tif (remainingDp) {\n\t\t\tawait adapter.setStateChangedAsync(remainingDp, { val: 0, ack: true });\n\t\t}\n\t\tawait onTimeoutCallback();\n\t}, durationSeconds * 1000);\n}\n\n/**\n * Dynamically checks whether the current time is enabled for circulation according to the Luxtronik schedules.\n *\n * @param adapter Die aktuelle Adapter-Instanz.\n */\nasync function isZipAllowedBySchedule(adapter: LuxtronikAdapter): Promise<boolean> {\n\tconst config = adapter.config;\n\n\t// Bei Modbus oder deaktivierten Hardware-Timern immer freigeben\n\tif (config.zip_control_mode === 'modbus' || config.zip_lWP_aktiv === true) {\n\t\treturn true;\n\t}\n\n\ttry {\n\t\tconst tableState = await adapter.getStateAsync(getDpPath('hotWaterCircPumpTimerTableSelected'));\n\t\tconst tableMode = tableState ? Number(tableState.val) : 0;\n\n\t\tconst now = new Date();\n\t\tconst day = now.getDay();\n\t\tconst currentSeconds = now.getHours() * 3600 + now.getMinutes() * 60 + now.getSeconds();\n\n\t\tlet prefix = 'Zirkulation_MoSo';\n\t\tlet endSuffix = 'End';\n\n\t\tif (tableMode === 1) {\n\t\t\tprefix = day >= 1 && day <= 5 ? 'Zirkulation_MoFr' : 'Zirkulation_SaSo';\n\t\t\tendSuffix = 'Ende';\n\t\t} else if (tableMode === 2) {\n\t\t\tprefix = `Zirkulation_${LEGACY_DAYS[day]}`;\n\t\t\tendSuffix = 'Ende';\n\t\t}\n\n\t\tlet isAllowed = false;\n\n\t\tfor (let i = 1; i <= 5; i++) {\n\t\t\tconst startKey = `${prefix}_Start${i}`;\n\t\t\tconst endKey = `${prefix}_${endSuffix}${i}`;\n\n\t\t\tconst startState = await adapter.getStateAsync(getDpPath(startKey));\n\t\t\tconst endState = await adapter.getStateAsync(getDpPath(endKey));\n\n\t\t\tif (startState && startState.val && endState && endState.val) {\n\t\t\t\tconst startSec = timeStringToSeconds(String(startState.val));\n\t\t\t\tconst endSec = timeStringToSeconds(String(endState.val));\n\n\t\t\t\tif (startSec !== endSec) {\n\t\t\t\t\tlet actualEndSec = endSec;\n\t\t\t\t\tif (endSec === 0 && startSec > 0) {\n\t\t\t\t\t\tactualEndSec = 86400; // Midnight\n\t\t\t\t\t}\n\t\t\t\t\tif (currentSeconds >= startSec && currentSeconds <= actualEndSec) {\n\t\t\t\t\t\tisAllowed = true;\n\t\t\t\t\t\tbreak;\n\t\t\t\t\t}\n\t\t\t\t}\n\t\t\t}\n\t\t}\n\t\treturn isAllowed;\n\t} catch (err: unknown) {\n\t\tconst msg = err instanceof Error ? err.message : String(err);\n\t\tif (adapter.isDebugLogActive) {\n\t\t\twriteLog(`[ZIP] Error during schedule check: ${msg}`, 'error');\n\t\t}\n\t\treturn true;\n\t}\n}\n\n// =========================================================\n// MAIN EXPORTS\n// =========================================================\n\n/**\n * Restores the original circulation pump configuration from the saved cache.\n *\n * @param adapter Die aktuelle Adapter-Instanz.\n */\nexport async function restoreOriginalZipConfig(adapter: LuxtronikAdapter): Promise<void> {\n\tif (!adapter.originalZipConfig) {\n\t\treturn;\n\t}\n\n\ttry {\n\t\tfor (const [key, val] of Object.entries(adapter.originalZipConfig)) {\n\t\t\tif (val === null || val === undefined) {\n\t\t\t\tcontinue;\n\t\t\t}\n\n\t\t\tconst def = STATE_MAPPING[key];\n\t\t\tif (!def || !def.luxWriteId) {\n\t\t\t\tcontinue;\n\t\t\t}\n\n\t\t\tlet rawVal = val;\n\n\t\t\tif (def.role === 'value.datetime' && typeof val === 'string') {\n\t\t\t\trawVal = timeStringToSeconds(val);\n\t\t\t}\n\n\t\t\tconst targetPath = getDpPath(key);\n\t\t\tif (targetPath) {\n\t\t\t\tawait adapter.setState(targetPath, { val: val, ack: true });\n\t\t\t}\n\n\t\t\tconst luxId = Number(def.luxWriteId);\n\t\t\tif (!isNaN(luxId)) {\n\t\t\t\tawait queueWrite(adapter, luxId, Number(rawVal));\n\t\t\t\tawait new Promise<void>(resolve => {\n\t\t\t\t\tadapter.setTimeout(() => resolve(), CONSTANTS.WRITE_DELAY);\n\t\t\t\t});\n\t\t\t}\n\t\t}\n\t} catch (err: unknown) {\n\t\tconst msg = err instanceof Error ? err.message : String(err);\n\t\twriteLog(`Error restoring ZIP configuration: ${msg}`, 'error');\n\t} finally {\n\t\tadapter.originalZipConfig = null;\n\t}\n}\n\n/**\n * Stops the active circulation pump macro and deaeration program across all modes.\n *\n * @param adapter Die aktuelle Adapter-Instanz.\n */\nexport async function stopZipAndDeaeration(adapter: LuxtronikAdapter): Promise<void> {\n\tconst mode = adapter.config.zip_control_mode || 'controller';\n\tconst actors = adapter.config.actors || [];\n\tconst validActors = actors.filter((a: any) => a.zip_external_relay_id && a.zip_external_relay_id.trim() !== '');\n\n\tclearZipTimer(adapter);\n\n\t// 1. Externe Aktoren abschalten (falls Modus = 'actor' oder als Fallback konfiguriert)\n\tif (mode === 'actor' || validActors.length > 0) {\n\t\ttry {\n\t\t\tfor (const actor of validActors) {\n\t\t\t\tawait adapter.setForeignStateAsync(actor.zip_external_relay_id, false, false);\n\t\t\t}\n\t\t\tif (adapter.isDebugLogActive && validActors.length > 0) {\n\t\t\t\twriteLog(`[ZIP] Emergency/Timeout stop sent for external relays.`, 'debug');\n\t\t\t}\n\t\t} catch (err: unknown) {\n\t\t\tconst msg = err instanceof Error ? err.message : String(err);\n\t\t\twriteLog(`[ZIP] Error switching off external relays: ${msg}`, 'error');\n\t\t}\n\t}\n\n\t// 2. Modbus Coil 7 abschalten (falls Modus = 'modbus')\n\tif (mode === 'modbus') {\n\t\ttry {\n\t\t\tif (adapter.modbusManager && adapter.modbusManager.isAvailable) {\n\t\t\t\tawait adapter.modbusManager.writeRegister(CONSTANTS.MODBUS_COIL_ZIP, 0, true);\n\t\t\t\tif (adapter.isDebugLogActive) {\n\t\t\t\t\twriteLog(`[ZIP] Modbus Coil ${CONSTANTS.MODBUS_COIL_ZIP} switched OFF.`, 'debug');\n\t\t\t\t}\n\t\t\t}\n\t\t} catch (err: unknown) {\n\t\t\tconst msg = err instanceof Error ? err.message : String(err);\n\t\t\twriteLog(`[ZIP] Error switching off Modbus Coil 7: ${msg}`, 'error');\n\t\t}\n\t}\n\n\t// 3. Internen Luxtronik-Regler zur\u00FCcksetzen (falls Modus = 'controller' oder noch ein altes Makro lief)\n\ttry {\n\t\tconst activateZipState = await adapter.getStateAsync(getDpPath('Activate_Zip'));\n\t\tconst runDeaerateState = await adapter.getStateAsync(getDpPath('runDeaerate'));\n\n\t\tconst isZipActive = activateZipState?.val === true || adapter.originalZipConfig !== null;\n\t\tconst isDeaerateActive = runDeaerateState?.val === 1 || runDeaerateState?.val === true;\n\n\t\tif (mode === 'controller' && (isZipActive || isDeaerateActive)) {\n\t\t\tif (adapter.isDebugLogActive) {\n\t\t\t\twriteLog('Stopping active controller ZIP macro and deaeration program...', 'info');\n\t\t\t}\n\n\t\t\tawait restoreOriginalZipConfig(adapter);\n\n\t\t\tawait safeRawWrite(adapter, 'runDeaerate', CONSTANTS.CMD_DEAERATE, 0);\n\t\t\tawait safeRawWrite(adapter, 'hotWaterCircPumpDeaerate', CONSTANTS.CMD_ZIP, 0);\n\n\t\t\tconst dpDeaerate = getDpPath('runDeaerate');\n\t\t\tconst dpCircDeaerate = getDpPath('hotWaterCircPumpDeaerate');\n\t\t\tif (dpDeaerate) {\n\t\t\t\tawait adapter.setOwnStateIfDifferent(dpDeaerate, false, true);\n\t\t\t}\n\t\t\tif (dpCircDeaerate) {\n\t\t\t\tawait adapter.setOwnStateIfDifferent(dpCircDeaerate, false, true);\n\t\t\t}\n\t\t}\n\n\t\tconst dpZip = getDpPath('Activate_Zip');\n\t\tif (dpZip) {\n\t\t\tawait adapter.setOwnStateIfDifferent(dpZip, false, true);\n\t\t}\n\t} catch (err: unknown) {\n\t\tconst msg = err instanceof Error ? err.message : String(err);\n\t\twriteLog(`Error stopping ZIP/Deaeration: ${msg}`, 'error');\n\t} finally {\n\t\t// GARANTIERTER RESET: Virtueller Status und Restlaufzeit immer auf AUS / 0 setzen\n\t\tconst virtualDp = getDpPath('Virtual_ZIP_Status');\n\t\tif (virtualDp) {\n\t\t\tawait adapter.setStateChangedAsync(virtualDp, { val: false, ack: true });\n\t\t}\n\t\tconst remainingDp = getDpPath('Virtual_ZIP_Remaining_Time');\n\t\tif (remainingDp) {\n\t\t\tawait adapter.setStateChangedAsync(remainingDp, { val: 0, ack: true });\n\t\t}\n\t}\n}\n\n/**\n * Activates the circulation pump (ZIP) via the selected control mode for a specified duration.\n *\n * @param adapter Die aktuelle Adapter-Instanz.\n * @param id Die ID des Datenpunkts.\n * @param durationSeconds Die Dauer in Sekunden.\n */\nexport async function handleActivateZip(adapter: LuxtronikAdapter, id: string, durationSeconds: number): Promise<void> {\n\tconst mode = adapter.config.zip_control_mode || 'controller';\n\tconst actors = adapter.config.actors || [];\n\tconst validActors = actors.filter((a: any) => a.zip_external_relay_id && a.zip_external_relay_id.trim() !== '');\n\n\tconst localId = id.replace(`${adapter.namespace}.`, '');\n\tawait adapter.setState(localId, { val: true, ack: true });\n\n\tif (durationSeconds <= 0) {\n\t\tawait stopZipAndDeaeration(adapter);\n\t\treturn;\n\t}\n\n\tconst safeDurationSeconds = Math.max(1, isNaN(durationSeconds) ? 60 : durationSeconds);\n\n\t// Pr\u00FCfen, ob die Pumpe bereits \u00FCber unseren Adapter-Timer l\u00E4uft\n\tconst virtualStatusState = await adapter.getStateAsync(getDpPath('Virtual_ZIP_Status'));\n\tconst isZipAlreadyRunning = Boolean(adapter.zipTimer) || virtualStatusState?.val === true;\n\n\tif (isZipAlreadyRunning) {\n\t\tif (adapter.isDebugLogActive) {\n\t\t\twriteLog(\n\t\t\t\t`[ZIP] Pump is already running (Mode: ${mode}). Extending timer to ${safeDurationSeconds}s.`,\n\t\t\t\t'debug',\n\t\t\t);\n\t\t}\n\t\tawait startZipTimerAndCountdown(adapter, safeDurationSeconds, async () => {\n\t\t\tawait stopZipAndDeaeration(adapter);\n\t\t});\n\t\treturn;\n\t}\n\n\t// =========================================================\n\t// WEICHE 1: EXTERNER AKTOR (z.B. Shelly)\n\t// =========================================================\n\tif (mode === 'actor') {\n\t\tif (validActors.length === 0) {\n\t\t\twriteLog('[ZIP] Mode is set to external actor, but no valid actor OIDs are configured!', 'warn');\n\t\t\tawait adapter.setState(localId, { val: false, ack: true });\n\t\t\treturn;\n\t\t}\n\n\t\tif (adapter.isDebugLogActive) {\n\t\t\twriteLog(`[ZIP] Switching ON ${validActors.length} external actor(s) for ${safeDurationSeconds}s`, 'debug');\n\t\t}\n\n\t\tfor (const actor of validActors) {\n\t\t\ttry {\n\t\t\t\tawait adapter.setForeignStateAsync(actor.zip_external_relay_id, true, false);\n\t\t\t} catch (err) {\n\t\t\t\tconst msg = err instanceof Error ? err.message : String(err);\n\t\t\t\twriteLog(`[ZIP] Error switching on ${actor.zip_external_relay_id}: ${msg}`, 'error');\n\t\t\t}\n\t\t}\n\n\t\tconst virtualDp = getDpPath('Virtual_ZIP_Status');\n\t\tif (virtualDp) {\n\t\t\tawait adapter.setStateChangedAsync(virtualDp, { val: true, ack: true });\n\t\t}\n\n\t\tawait startZipTimerAndCountdown(adapter, safeDurationSeconds, async () => {\n\t\t\tawait stopZipAndDeaeration(adapter);\n\t\t});\n\t\treturn;\n\t}\n\n\t// =========================================================\n\t// WEICHE 2: MODBUS TCP (Coil 7)\n\t// =========================================================\n\tif (mode === 'modbus') {\n\t\tif (!adapter.modbusManager || !adapter.modbusManager.isAvailable) {\n\t\t\twriteLog('[ZIP] Mode is set to Modbus TCP, but Modbus is disabled or unreachable!', 'warn');\n\t\t\tawait adapter.setState(localId, { val: false, ack: true });\n\t\t\treturn;\n\t\t}\n\n\t\tif (adapter.isDebugLogActive) {\n\t\t\twriteLog(\n\t\t\t\t`[ZIP] Switching ON via Modbus Coil ${CONSTANTS.MODBUS_COIL_ZIP} for ${safeDurationSeconds}s`,\n\t\t\t\t'debug',\n\t\t\t);\n\t\t}\n\n\t\tawait adapter.modbusManager.writeRegister(CONSTANTS.MODBUS_COIL_ZIP, 1, true);\n\n\t\tconst virtualDp = getDpPath('Virtual_ZIP_Status');\n\t\tif (virtualDp) {\n\t\t\tawait adapter.setStateChangedAsync(virtualDp, { val: true, ack: true });\n\t\t}\n\n\t\tawait startZipTimerAndCountdown(adapter, safeDurationSeconds, async () => {\n\t\t\tawait stopZipAndDeaeration(adapter);\n\t\t});\n\t\treturn;\n\t}\n\n\t// =========================================================\n\t// WEICHE 3: INTERNER LUXTRONIK REGLER (Standard)\n\t// =========================================================\n\tconst bzState = await adapter.getStateAsync(getDpPath('WP_BZ_akt'));\n\tconst bzVal = bzState ? Number(bzState.val) : 5;\n\n\tconst [wwIstS, wwSollS, wwHystS, rLState, rSollState, hzHystState] = await Promise.all([\n\t\tadapter.getStateAsync(getDpPath('Wamwassertemperatur_Ist')),\n\t\tadapter.getStateAsync(getDpPath('Wamwassertemperatur_Soll')),\n\t\tadapter.getStateAsync(getDpPath('hotWaterTemperatureHysteresis')),\n\t\tadapter.getStateAsync(getDpPath('temperature_return')),\n\t\tadapter.getStateAsync(getDpPath('temperature_target_return')),\n\t\tadapter.getStateAsync(getDpPath('returnTemperatureHysteresis')),\n\t]);\n\n\tconst useDeaeration =\n\t\tbzVal === 5 &&\n\t\tNumber(wwIstS?.val) > Number(wwSollS?.val) - Number(wwHystS?.val) &&\n\t\tNumber(rLState?.val) > Number(rSollState?.val) - Number(hzHystState?.val);\n\n\tif (useDeaeration) {\n\t\tawait safeRawWrite(adapter, 'runDeaerate', CONSTANTS.CMD_DEAERATE, 1);\n\t\tawait safeRawWrite(adapter, 'hotWaterCircPumpDeaerate', CONSTANTS.CMD_ZIP, 1);\n\n\t\tconst dpDeaerate = getDpPath('runDeaerate');\n\t\tconst dpCircDeaerate = getDpPath('hotWaterCircPumpDeaerate');\n\t\tif (dpDeaerate) {\n\t\t\tawait adapter.setOwnStateIfDifferent(dpDeaerate, true, true);\n\t\t}\n\t\tif (dpCircDeaerate) {\n\t\t\tawait adapter.setOwnStateIfDifferent(dpCircDeaerate, true, true);\n\t\t}\n\t} else {\n\t\tconst onTimeMinutes = Math.ceil(safeDurationSeconds / 60);\n\t\tif (!adapter.originalZipConfig) {\n\t\t\tconst keysToSave = [\n\t\t\t\t'hotWaterCircPumpTimerTableSelected',\n\t\t\t\t'WW_MoSo_Start1',\n\t\t\t\t'WW_MoSo_End1',\n\t\t\t\t'WW_MoSo_Start2',\n\t\t\t\t'WW_MoSo_End2',\n\t\t\t\t'WW_MoSo_Start3',\n\t\t\t\t'WW_MoSo_End3',\n\t\t\t\t'WW_MoSo_Start4',\n\t\t\t\t'WW_MoSo_End4',\n\t\t\t\t'WW_MoSo_Start5',\n\t\t\t\t'WW_MoSo_End5',\n\t\t\t\t'hotWaterCircPumpOnTime',\n\t\t\t\t'hotWaterCircPumpOffTime',\n\t\t\t] as const;\n\n\t\t\tconst states = await Promise.all(keysToSave.map(key => adapter.getStateAsync(getDpPath(key as any))));\n\n\t\t\tadapter.originalZipConfig = {};\n\t\t\tkeysToSave.forEach((key, index) => {\n\t\t\t\tif (adapter.originalZipConfig) {\n\t\t\t\t\tadapter.originalZipConfig[key] = states[index] ? states[index].val : null;\n\t\t\t\t}\n\t\t\t});\n\t\t}\n\n\t\tconst updates = [\n\t\t\t{ key: 'hotWaterCircPumpTimerTableSelected', raw: 0 },\n\t\t\t{ key: 'WW_MoSo_Start1', raw: 0 },\n\t\t\t{ key: 'WW_MoSo_End1', raw: CONSTANTS.END_OF_DAY },\n\t\t\t{ key: 'WW_MoSo_Start2', raw: 0 },\n\t\t\t{ key: 'WW_MoSo_End2', raw: 0 },\n\t\t\t{ key: 'hotWaterCircPumpOnTime', raw: onTimeMinutes },\n\t\t\t{ key: 'hotWaterCircPumpOffTime', raw: 60 },\n\t\t] as const;\n\n\t\tfor (const u of updates) {\n\t\t\tconst def = STATE_MAPPING[u.key];\n\t\t\tif (def && def.luxWriteId) {\n\t\t\t\tawait safeRawWrite(adapter, u.key, parseInt(def.luxWriteId, 10), u.raw);\n\t\t\t}\n\t\t}\n\t}\n\n\tconst virtualDp = getDpPath('Virtual_ZIP_Status');\n\tif (virtualDp) {\n\t\tawait adapter.setStateChangedAsync(virtualDp, { val: true, ack: true });\n\t}\n\n\tawait startZipTimerAndCountdown(adapter, safeDurationSeconds, async () => {\n\t\tawait stopZipAndDeaeration(adapter);\n\t});\n}\n\n/**\n * Abonniert die in der Konfiguration hinterlegten Bewegungsmelder (Foreign States).\n *\n * @param adapter Die aktuelle Adapter-Instanz.\n */\nexport function subscribeMotionSensors(adapter: LuxtronikAdapter): void {\n\tconst config = adapter.config;\n\tif (config.motion_sensors_aktiv && Array.isArray(config.motionSensors)) {\n\t\tfor (const sensor of config.motionSensors) {\n\t\t\tif (sensor.oid && typeof sensor.oid === 'string' && sensor.oid.trim() !== '') {\n\t\t\t\tadapter.subscribeForeignStates(sensor.oid.trim());\n\t\t\t\tif (adapter.isDebugLogActive) {\n\t\t\t\t\twriteLog(`Motion sensor subscribed: ${sensor.name} (${sensor.oid})`, 'info');\n\t\t\t\t}\n\t\t\t}\n\t\t}\n\t}\n}\n\n/**\n * Pr\u00FCft bei einem StateChange, ob ein abonnierter Bewegungsmelder ausgel\u00F6st hat.\n *\n * @param adapter Die aktuelle Adapter-Instanz.\n * @param id Die ID des Datenpunkts.\n * @param state Der neue Status des Datenpunkts.\n */\nexport async function checkAndHandleMotionSensor(\n\tadapter: LuxtronikAdapter,\n\tid: string,\n\tstate: ioBroker.State,\n): Promise<boolean> {\n\tconst config = adapter.config;\n\n\tif (!config.motion_sensors_aktiv || !config.motionSensors || !Array.isArray(config.motionSensors)) {\n\t\treturn false;\n\t}\n\n\tconst matchedSensor = config.motionSensors.find((s: any) => s.oid && s.oid.trim() === id);\n\tif (!matchedSensor) {\n\t\treturn false;\n\t}\n\n\tif (state.val === true) {\n\t\tif (!state.ack) {\n\t\t\treturn false;\n\t\t}\n\t\tconst isAllowedBySchedule = await isZipAllowedBySchedule(adapter);\n\n\t\tif (!isAllowedBySchedule) {\n\t\t\tif (adapter.isDebugLogActive) {\n\t\t\t\twriteLog(\n\t\t\t\t\t`Motion registered at sensor '${matchedSensor.name || id}', but action ignored because it is outside the configured Luxtronik ZIP schedule.`,\n\t\t\t\t\t'debug',\n\t\t\t\t);\n\t\t\t}\n\t\t\treturn true;\n\t\t}\n\n\t\tconst activateZipState = await adapter.getStateAsync(getDpPath('Activate_Zip'));\n\t\tconst now = Date.now();\n\t\tconst lastZipChange = activateZipState?.lc || 0;\n\t\tconst isCurrentlyActive = activateZipState?.val === true;\n\n\t\tif (isCurrentlyActive || now - lastZipChange > (config.zip_last_run_min || 600) * 1000) {\n\t\t\tif (adapter.isDebugLogActive) {\n\t\t\t\twriteLog(\n\t\t\t\t\t`Motion registered at sensor '${matchedSensor.name || id}'. Launching or extending circulation pump ZIP macro sequence.`,\n\t\t\t\t\t'debug',\n\t\t\t\t);\n\t\t\t}\n\t\t\tawait adapter.setState(getDpPath('Activate_Zip'), { val: true, ack: false });\n\t\t} else {\n\t\t\tif (adapter.isDebugLogActive) {\n\t\t\t\twriteLog(\n\t\t\t\t\t`Motion registered at sensor '${matchedSensor.name || id}' but circulation pump execution suppressed due to anti-cycling protective interval timer.`,\n\t\t\t\t\t'debug',\n\t\t\t\t);\n\t\t\t}\n\t\t}\n\t}\n\n\treturn true;\n}\n\n/**\n * Deaktiviert die regul\u00E4ren Hardware-Timer der Zirkulationspumpe beim Adapter-Start.\n *\n * @param adapter Die aktuelle Adapter-Instanz.\n */\nexport async function disableHardwareZipTimer(adapter: LuxtronikAdapter): Promise<void> {\n\tconst config = adapter.config;\n\n\t// Bei Modbus-Steuerung m\u00FCssen wir die internen Timer nicht anfassen\n\tif (config.zip_control_mode === 'modbus') {\n\t\treturn;\n\t}\n\n\tif (config.zip_lWP_aktiv === true) {\n\t\tif (adapter.isDebugLogActive) {\n\t\t\twriteLog('Applying safe hardware defaults for ZIP timers...', 'info');\n\t\t}\n\n\t\ttry {\n\t\t\tawait safeRawWrite(adapter, 'hotWaterCircPumpTimerTableSelected', 506, 0);\n\t\t\tawait adapter.setOwnStateIfDifferent(getDpPath('hotWaterCircPumpTimerTableSelected'), 0, true);\n\n\t\t\tawait safeRawWrite(adapter, 'hotWaterCircPumpOnTime', 697, 0);\n\t\t\tawait adapter.setOwnStateIfDifferent(getDpPath('hotWaterCircPumpOnTime'), 0, true);\n\n\t\t\tawait safeRawWrite(adapter, 'hotWaterCircPumpOffTime', 698, 60);\n\t\t\tawait adapter.setOwnStateIfDifferent(getDpPath('hotWaterCircPumpOffTime'), 60, true);\n\n\t\t\tconst timeIds = [\n\t\t\t\t{ key: 'Zirkulation_MoSo_Start1', id: 507 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_End1', id: 508 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_Start2', id: 509 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_End2', id: 510 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_Start3', id: 511 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_End3', id: 512 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_Start4', id: 513 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_End4', id: 514 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_Start5', id: 515 },\n\t\t\t\t{ key: 'Zirkulation_MoSo_End5', id: 516 },\n\t\t\t] as const;\n\n\t\t\tfor (const t of timeIds) {\n\t\t\t\tawait safeRawWrite(adapter, t.key, t.id, 0);\n\t\t\t\tawait adapter.setOwnStateIfDifferent(getDpPath(t.key), '00:00', true);\n\t\t\t}\n\t\t} catch (err: unknown) {\n\t\t\tconst msg = err instanceof Error ? err.message : String(err);\n\t\t\twriteLog(`Error applying safe ZIP defaults: ${msg}`, 'error');\n\t\t}\n\t}\n}\n"],
5
5
  "mappings": ";;;;;;;;;;;;;;;;;;AAAA;AAAA;AAAA;AAAA;AAAA;AAAA;AAAA;AAAA;AAAA;AAAA;AAAA,qBAAoC;AACpC,oBAAyB;AACzB,0BAA2B;AAC3B,0BAAyC;AAOzC,MAAM,YAAY;AAAA,EACjB,cAAc;AAAA,EACd,SAAS;AAAA,EACT,iBAAiB;AAAA,EACjB,YAAY;AAAA,EACZ,aAAa;AAAA,EACb,mBAAmB;AAAA;AACpB;AAKA,MAAM,cAAc,CAAC,WAAW,UAAU,YAAY,YAAY,cAAc,WAAW,SAAS;AAoBpG,eAAe,aACd,SACA,KACA,OACA,UACgB;AAChB,QAAM,aAAS,+BAAU,GAAG;AAC5B,MAAI,CAAC,QAAQ;AACZ;AAAA,EACD;AAEA,QAAM,QAAQ,MAAM,QAAQ,cAAc,MAAM;AAEhD,MAAI,SAAS,MAAM,QAAQ,MAAM;AAChC,QAAI,aAA4B;AAEhC,QAAI,OAAO,MAAM,QAAQ,WAAW;AACnC,mBAAa,MAAM,MAAM,IAAI;AAAA,IAC9B,WAAW,OAAO,MAAM,QAAQ,UAAU;AACzC,mBAAa,MAAM;AAAA,IACpB,WAAW,OAAO,MAAM,QAAQ,UAAU;AACzC,uBAAa,oCAAoB,MAAM,GAAG;AAAA,IAC3C;AAEA,QAAI,eAAe,UAAU;AAC5B,UAAI,QAAQ,kBAAkB;AAC7B,oCAAS,0BAA0B,GAAG,2BAA2B,QAAQ,qBAAqB,OAAO;AAAA,MACtG;AACA;AAAA,IACD;AAAA,EACD;AAEA,MAAI,QAAQ,kBAAkB;AAC7B,gCAAS,wCAAwC,QAAQ,gBAAgB,KAAK,KAAK,GAAG,QAAQ,OAAO;AAAA,EACtG;AACA,YAAM,gCAAW,SAAS,OAAO,QAAQ;AAEzC,QAAM,IAAI,QAAc,aAAW;AAClC,YAAQ,WAAW,SAAS,UAAU,WAAW;AAAA,EAClD,CAAC;AACF;AAOA,SAAS,cAAc,SAAiC;AACvD,MAAI,QAAQ,UAAU;AACrB,YAAQ,aAAa,QAAQ,QAAQ;AACrC,YAAQ,WAAW;AAAA,EACpB;AACA,MAAI,QAAQ,sBAAsB;AACjC,YAAQ,cAAc,QAAQ,oBAAoB;AAClD,YAAQ,uBAAuB;AAAA,EAChC;AACA,UAAQ,aAAa;AACtB;AASA,eAAe,0BACd,SACA,iBACA,mBACgB;AAChB,gBAAc,OAAO;AAErB,UAAQ,aAAa,KAAK,IAAI,IAAI,kBAAkB;AAEpD,QAAM,kBAAc,+BAAU,4BAA4B;AAC1D,MAAI,aAAa;AAChB,UAAM,QAAQ,qBAAqB,aAAa,EAAE,KAAK,iBAAiB,KAAK,KAAK,CAAC;AAAA,EACpF;AAGA,UAAQ,uBAAuB,QAAQ,YAAY,YAAY;AAC9D,QAAI,CAAC,QAAQ,YAAY;AACxB;AAAA,IACD;AACA,UAAM,YAAY,KAAK,IAAI,GAAG,KAAK,OAAO,QAAQ,aAAa,KAAK,IAAI,KAAK,GAAI,CAAC;AAClF,QAAI,aAAa;AAChB,YAAM,QAAQ,qBAAqB,aAAa,EAAE,KAAK,WAAW,KAAK,KAAK,CAAC;AAAA,IAC9E;AAAA,EACD,GAAG,UAAU,iBAAiB;AAG9B,UAAQ,WAAW,QAAQ,WAAW,YAAY;AACjD,kBAAc,OAAO;AACrB,QAAI,aAAa;AAChB,YAAM,QAAQ,qBAAqB,aAAa,EAAE,KAAK,GAAG,KAAK,KAAK,CAAC;AAAA,IACtE;AACA,UAAM,kBAAkB;AAAA,EACzB,GAAG,kBAAkB,GAAI;AAC1B;AAOA,eAAe,uBAAuB,SAA6C;AAClF,QAAM,SAAS,QAAQ;AAGvB,MAAI,OAAO,qBAAqB,YAAY,OAAO,kBAAkB,MAAM;AAC1E,WAAO;AAAA,EACR;AAEA,MAAI;AACH,UAAM,aAAa,MAAM,QAAQ,kBAAc,+BAAU,oCAAoC,CAAC;AAC9F,UAAM,YAAY,aAAa,OAAO,WAAW,GAAG,IAAI;AAExD,UAAM,MAAM,oBAAI,KAAK;AACrB,UAAM,MAAM,IAAI,OAAO;AACvB,UAAM,iBAAiB,IAAI,SAAS,IAAI,OAAO,IAAI,WAAW,IAAI,KAAK,IAAI,WAAW;AAEtF,QAAI,SAAS;AACb,QAAI,YAAY;AAEhB,QAAI,cAAc,GAAG;AACpB,eAAS,OAAO,KAAK,OAAO,IAAI,qBAAqB;AACrD,kBAAY;AAAA,IACb,WAAW,cAAc,GAAG;AAC3B,eAAS,eAAe,YAAY,GAAG,CAAC;AACxC,kBAAY;AAAA,IACb;AAEA,QAAI,YAAY;AAEhB,aAAS,IAAI,GAAG,KAAK,GAAG,KAAK;AAC5B,YAAM,WAAW,GAAG,MAAM,SAAS,CAAC;AACpC,YAAM,SAAS,GAAG,MAAM,IAAI,SAAS,GAAG,CAAC;AAEzC,YAAM,aAAa,MAAM,QAAQ,kBAAc,+BAAU,QAAQ,CAAC;AAClE,YAAM,WAAW,MAAM,QAAQ,kBAAc,+BAAU,MAAM,CAAC;AAE9D,UAAI,cAAc,WAAW,OAAO,YAAY,SAAS,KAAK;AAC7D,cAAM,eAAW,oCAAoB,OAAO,WAAW,GAAG,CAAC;AAC3D,cAAM,aAAS,oCAAoB,OAAO,SAAS,GAAG,CAAC;AAEvD,YAAI,aAAa,QAAQ;AACxB,cAAI,eAAe;AACnB,cAAI,WAAW,KAAK,WAAW,GAAG;AACjC,2BAAe;AAAA,UAChB;AACA,cAAI,kBAAkB,YAAY,kBAAkB,cAAc;AACjE,wBAAY;AACZ;AAAA,UACD;AAAA,QACD;AAAA,MACD;AAAA,IACD;AACA,WAAO;AAAA,EACR,SAAS,KAAc;AACtB,UAAM,MAAM,eAAe,QAAQ,IAAI,UAAU,OAAO,GAAG;AAC3D,QAAI,QAAQ,kBAAkB;AAC7B,kCAAS,sCAAsC,GAAG,IAAI,OAAO;AAAA,IAC9D;AACA,WAAO;AAAA,EACR;AACD;AAWA,eAAsB,yBAAyB,SAA0C;AACxF,MAAI,CAAC,QAAQ,mBAAmB;AAC/B;AAAA,EACD;AAEA,MAAI;AACH,eAAW,CAAC,KAAK,GAAG,KAAK,OAAO,QAAQ,QAAQ,iBAAiB,GAAG;AACnE,UAAI,QAAQ,QAAQ,QAAQ,QAAW;AACtC;AAAA,MACD;AAEA,YAAM,MAAM,kCAAc,GAAG;AAC7B,UAAI,CAAC,OAAO,CAAC,IAAI,YAAY;AAC5B;AAAA,MACD;AAEA,UAAI,SAAS;AAEb,UAAI,IAAI,SAAS,oBAAoB,OAAO,QAAQ,UAAU;AAC7D,qBAAS,oCAAoB,GAAG;AAAA,MACjC;AAEA,YAAM,iBAAa,+BAAU,GAAG;AAChC,UAAI,YAAY;AACf,cAAM,QAAQ,SAAS,YAAY,EAAE,KAAU,KAAK,KAAK,CAAC;AAAA,MAC3D;AAEA,YAAM,QAAQ,OAAO,IAAI,UAAU;AACnC,UAAI,CAAC,MAAM,KAAK,GAAG;AAClB,kBAAM,gCAAW,SAAS,OAAO,OAAO,MAAM,CAAC;AAC/C,cAAM,IAAI,QAAc,aAAW;AAClC,kBAAQ,WAAW,MAAM,QAAQ,GAAG,UAAU,WAAW;AAAA,QAC1D,CAAC;AAAA,MACF;AAAA,IACD;AAAA,EACD,SAAS,KAAc;AACtB,UAAM,MAAM,eAAe,QAAQ,IAAI,UAAU,OAAO,GAAG;AAC3D,gCAAS,sCAAsC,GAAG,IAAI,OAAO;AAAA,EAC9D,UAAE;AACD,YAAQ,oBAAoB;AAAA,EAC7B;AACD;AAOA,eAAsB,qBAAqB,SAA0C;AACpF,QAAM,OAAO,QAAQ,OAAO,oBAAoB;AAChD,QAAM,SAAS,QAAQ,OAAO,UAAU,CAAC;AACzC,QAAM,cAAc,OAAO,OAAO,CAAC,MAAW,EAAE,yBAAyB,EAAE,sBAAsB,KAAK,MAAM,EAAE;AAE9G,gBAAc,OAAO;AAGrB,MAAI,SAAS,WAAW,YAAY,SAAS,GAAG;AAC/C,QAAI;AACH,iBAAW,SAAS,aAAa;AAChC,cAAM,QAAQ,qBAAqB,MAAM,uBAAuB,OAAO,KAAK;AAAA,MAC7E;AACA,UAAI,QAAQ,oBAAoB,YAAY,SAAS,GAAG;AACvD,oCAAS,0DAA0D,OAAO;AAAA,MAC3E;AAAA,IACD,SAAS,KAAc;AACtB,YAAM,MAAM,eAAe,QAAQ,IAAI,UAAU,OAAO,GAAG;AAC3D,kCAAS,8CAA8C,GAAG,IAAI,OAAO;AAAA,IACtE;AAAA,EACD;AAGA,MAAI,SAAS,UAAU;AACtB,QAAI;AACH,UAAI,QAAQ,iBAAiB,QAAQ,cAAc,aAAa;AAC/D,cAAM,QAAQ,cAAc,cAAc,UAAU,iBAAiB,GAAG,IAAI;AAC5E,YAAI,QAAQ,kBAAkB;AAC7B,sCAAS,qBAAqB,UAAU,eAAe,kBAAkB,OAAO;AAAA,QACjF;AAAA,MACD;AAAA,IACD,SAAS,KAAc;AACtB,YAAM,MAAM,eAAe,QAAQ,IAAI,UAAU,OAAO,GAAG;AAC3D,kCAAS,4CAA4C,GAAG,IAAI,OAAO;AAAA,IACpE;AAAA,EACD;AAGA,MAAI;AACH,UAAM,mBAAmB,MAAM,QAAQ,kBAAc,+BAAU,cAAc,CAAC;AAC9E,UAAM,mBAAmB,MAAM,QAAQ,kBAAc,+BAAU,aAAa,CAAC;AAE7E,UAAM,eAAc,qDAAkB,SAAQ,QAAQ,QAAQ,sBAAsB;AACpF,UAAM,oBAAmB,qDAAkB,SAAQ,MAAK,qDAAkB,SAAQ;AAElF,QAAI,SAAS,iBAAiB,eAAe,mBAAmB;AAC/D,UAAI,QAAQ,kBAAkB;AAC7B,oCAAS,kEAAkE,MAAM;AAAA,MAClF;AAEA,YAAM,yBAAyB,OAAO;AAEtC,YAAM,aAAa,SAAS,eAAe,UAAU,cAAc,CAAC;AACpE,YAAM,aAAa,SAAS,4BAA4B,UAAU,SAAS,CAAC;AAE5E,YAAM,iBAAa,+BAAU,aAAa;AAC1C,YAAM,qBAAiB,+BAAU,0BAA0B;AAC3D,UAAI,YAAY;AACf,cAAM,QAAQ,uBAAuB,YAAY,OAAO,IAAI;AAAA,MAC7D;AACA,UAAI,gBAAgB;AACnB,cAAM,QAAQ,uBAAuB,gBAAgB,OAAO,IAAI;AAAA,MACjE;AAAA,IACD;AAEA,UAAM,YAAQ,+BAAU,cAAc;AACtC,QAAI,OAAO;AACV,YAAM,QAAQ,uBAAuB,OAAO,OAAO,IAAI;AAAA,IACxD;AAAA,EACD,SAAS,KAAc;AACtB,UAAM,MAAM,eAAe,QAAQ,IAAI,UAAU,OAAO,GAAG;AAC3D,gCAAS,kCAAkC,GAAG,IAAI,OAAO;AAAA,EAC1D,UAAE;AAED,UAAM,gBAAY,+BAAU,oBAAoB;AAChD,QAAI,WAAW;AACd,YAAM,QAAQ,qBAAqB,WAAW,EAAE,KAAK,OAAO,KAAK,KAAK,CAAC;AAAA,IACxE;AACA,UAAM,kBAAc,+BAAU,4BAA4B;AAC1D,QAAI,aAAa;AAChB,YAAM,QAAQ,qBAAqB,aAAa,EAAE,KAAK,GAAG,KAAK,KAAK,CAAC;AAAA,IACtE;AAAA,EACD;AACD;AASA,eAAsB,kBAAkB,SAA2B,IAAY,iBAAwC;AACtH,QAAM,OAAO,QAAQ,OAAO,oBAAoB;AAChD,QAAM,SAAS,QAAQ,OAAO,UAAU,CAAC;AACzC,QAAM,cAAc,OAAO,OAAO,CAAC,MAAW,EAAE,yBAAyB,EAAE,sBAAsB,KAAK,MAAM,EAAE;AAE9G,QAAM,UAAU,GAAG,QAAQ,GAAG,QAAQ,SAAS,KAAK,EAAE;AACtD,QAAM,QAAQ,SAAS,SAAS,EAAE,KAAK,MAAM,KAAK,KAAK,CAAC;AAExD,MAAI,mBAAmB,GAAG;AACzB,UAAM,qBAAqB,OAAO;AAClC;AAAA,EACD;AAEA,QAAM,sBAAsB,KAAK,IAAI,GAAG,MAAM,eAAe,IAAI,KAAK,eAAe;AAGrF,QAAM,qBAAqB,MAAM,QAAQ,kBAAc,+BAAU,oBAAoB,CAAC;AACtF,QAAM,sBAAsB,QAAQ,QAAQ,QAAQ,MAAK,yDAAoB,SAAQ;AAErF,MAAI,qBAAqB;AACxB,QAAI,QAAQ,kBAAkB;AAC7B;AAAA,QACC,wCAAwC,IAAI,yBAAyB,mBAAmB;AAAA,QACxF;AAAA,MACD;AAAA,IACD;AACA,UAAM,0BAA0B,SAAS,qBAAqB,YAAY;AACzE,YAAM,qBAAqB,OAAO;AAAA,IACnC,CAAC;AACD;AAAA,EACD;AAKA,MAAI,SAAS,SAAS;AACrB,QAAI,YAAY,WAAW,GAAG;AAC7B,kCAAS,gFAAgF,MAAM;AAC/F,YAAM,QAAQ,SAAS,SAAS,EAAE,KAAK,OAAO,KAAK,KAAK,CAAC;AACzD;AAAA,IACD;AAEA,QAAI,QAAQ,kBAAkB;AAC7B,kCAAS,sBAAsB,YAAY,MAAM,0BAA0B,mBAAmB,KAAK,OAAO;AAAA,IAC3G;AAEA,eAAW,SAAS,aAAa;AAChC,UAAI;AACH,cAAM,QAAQ,qBAAqB,MAAM,uBAAuB,MAAM,KAAK;AAAA,MAC5E,SAAS,KAAK;AACb,cAAM,MAAM,eAAe,QAAQ,IAAI,UAAU,OAAO,GAAG;AAC3D,oCAAS,4BAA4B,MAAM,qBAAqB,KAAK,GAAG,IAAI,OAAO;AAAA,MACpF;AAAA,IACD;AAEA,UAAMA,iBAAY,+BAAU,oBAAoB;AAChD,QAAIA,YAAW;AACd,YAAM,QAAQ,qBAAqBA,YAAW,EAAE,KAAK,MAAM,KAAK,KAAK,CAAC;AAAA,IACvE;AAEA,UAAM,0BAA0B,SAAS,qBAAqB,YAAY;AACzE,YAAM,qBAAqB,OAAO;AAAA,IACnC,CAAC;AACD;AAAA,EACD;AAKA,MAAI,SAAS,UAAU;AACtB,QAAI,CAAC,QAAQ,iBAAiB,CAAC,QAAQ,cAAc,aAAa;AACjE,kCAAS,2EAA2E,MAAM;AAC1F,YAAM,QAAQ,SAAS,SAAS,EAAE,KAAK,OAAO,KAAK,KAAK,CAAC;AACzD;AAAA,IACD;AAEA,QAAI,QAAQ,kBAAkB;AAC7B;AAAA,QACC,sCAAsC,UAAU,eAAe,QAAQ,mBAAmB;AAAA,QAC1F;AAAA,MACD;AAAA,IACD;AAEA,UAAM,QAAQ,cAAc,cAAc,UAAU,iBAAiB,GAAG,IAAI;AAE5E,UAAMA,iBAAY,+BAAU,oBAAoB;AAChD,QAAIA,YAAW;AACd,YAAM,QAAQ,qBAAqBA,YAAW,EAAE,KAAK,MAAM,KAAK,KAAK,CAAC;AAAA,IACvE;AAEA,UAAM,0BAA0B,SAAS,qBAAqB,YAAY;AACzE,YAAM,qBAAqB,OAAO;AAAA,IACnC,CAAC;AACD;AAAA,EACD;AAKA,QAAM,UAAU,MAAM,QAAQ,kBAAc,+BAAU,WAAW,CAAC;AAClE,QAAM,QAAQ,UAAU,OAAO,QAAQ,GAAG,IAAI;AAE9C,QAAM,CAAC,QAAQ,SAAS,SAAS,SAAS,YAAY,WAAW,IAAI,MAAM,QAAQ,IAAI;AAAA,IACtF,QAAQ,kBAAc,+BAAU,yBAAyB,CAAC;AAAA,IAC1D,QAAQ,kBAAc,+BAAU,0BAA0B,CAAC;AAAA,IAC3D,QAAQ,kBAAc,+BAAU,+BAA+B,CAAC;AAAA,IAChE,QAAQ,kBAAc,+BAAU,oBAAoB,CAAC;AAAA,IACrD,QAAQ,kBAAc,+BAAU,2BAA2B,CAAC;AAAA,IAC5D,QAAQ,kBAAc,+BAAU,6BAA6B,CAAC;AAAA,EAC/D,CAAC;AAED,QAAM,gBACL,UAAU,KACV,OAAO,iCAAQ,GAAG,IAAI,OAAO,mCAAS,GAAG,IAAI,OAAO,mCAAS,GAAG,KAChE,OAAO,mCAAS,GAAG,IAAI,OAAO,yCAAY,GAAG,IAAI,OAAO,2CAAa,GAAG;AAEzE,MAAI,eAAe;AAClB,UAAM,aAAa,SAAS,eAAe,UAAU,cAAc,CAAC;AACpE,UAAM,aAAa,SAAS,4BAA4B,UAAU,SAAS,CAAC;AAE5E,UAAM,iBAAa,+BAAU,aAAa;AAC1C,UAAM,qBAAiB,+BAAU,0BAA0B;AAC3D,QAAI,YAAY;AACf,YAAM,QAAQ,uBAAuB,YAAY,MAAM,IAAI;AAAA,IAC5D;AACA,QAAI,gBAAgB;AACnB,YAAM,QAAQ,uBAAuB,gBAAgB,MAAM,IAAI;AAAA,IAChE;AAAA,EACD,OAAO;AACN,UAAM,gBAAgB,KAAK,KAAK,sBAAsB,EAAE;AACxD,QAAI,CAAC,QAAQ,mBAAmB;AAC/B,YAAM,aAAa;AAAA,QAClB;AAAA,QACA;AAAA,QACA;AAAA,QACA;AAAA,QACA;AAAA,QACA;AAAA,QACA;AAAA,QACA;AAAA,QACA;AAAA,QACA;AAAA,QACA;AAAA,QACA;AAAA,QACA;AAAA,MACD;AAEA,YAAM,SAAS,MAAM,QAAQ,IAAI,WAAW,IAAI,SAAO,QAAQ,kBAAc,+BAAU,GAAU,CAAC,CAAC,CAAC;AAEpG,cAAQ,oBAAoB,CAAC;AAC7B,iBAAW,QAAQ,CAAC,KAAK,UAAU;AAClC,YAAI,QAAQ,mBAAmB;AAC9B,kBAAQ,kBAAkB,GAAG,IAAI,OAAO,KAAK,IAAI,OAAO,KAAK,EAAE,MAAM;AAAA,QACtE;AAAA,MACD,CAAC;AAAA,IACF;AAEA,UAAM,UAAU;AAAA,MACf,EAAE,KAAK,sCAAsC,KAAK,EAAE;AAAA,MACpD,EAAE,KAAK,kBAAkB,KAAK,EAAE;AAAA,MAChC,EAAE,KAAK,gBAAgB,KAAK,UAAU,WAAW;AAAA,MACjD,EAAE,KAAK,kBAAkB,KAAK,EAAE;AAAA,MAChC,EAAE,KAAK,gBAAgB,KAAK,EAAE;AAAA,MAC9B,EAAE,KAAK,0BAA0B,KAAK,cAAc;AAAA,MACpD,EAAE,KAAK,2BAA2B,KAAK,GAAG;AAAA,IAC3C;AAEA,eAAW,KAAK,SAAS;AACxB,YAAM,MAAM,kCAAc,EAAE,GAAG;AAC/B,UAAI,OAAO,IAAI,YAAY;AAC1B,cAAM,aAAa,SAAS,EAAE,KAAK,SAAS,IAAI,YAAY,EAAE,GAAG,EAAE,GAAG;AAAA,MACvE;AAAA,IACD;AAAA,EACD;AAEA,QAAM,gBAAY,+BAAU,oBAAoB;AAChD,MAAI,WAAW;AACd,UAAM,QAAQ,qBAAqB,WAAW,EAAE,KAAK,MAAM,KAAK,KAAK,CAAC;AAAA,EACvE;AAEA,QAAM,0BAA0B,SAAS,qBAAqB,YAAY;AACzE,UAAM,qBAAqB,OAAO;AAAA,EACnC,CAAC;AACF;AAOO,SAAS,uBAAuB,SAAiC;AACvE,QAAM,SAAS,QAAQ;AACvB,MAAI,OAAO,wBAAwB,MAAM,QAAQ,OAAO,aAAa,GAAG;AACvE,eAAW,UAAU,OAAO,eAAe;AAC1C,UAAI,OAAO,OAAO,OAAO,OAAO,QAAQ,YAAY,OAAO,IAAI,KAAK,MAAM,IAAI;AAC7E,gBAAQ,uBAAuB,OAAO,IAAI,KAAK,CAAC;AAChD,YAAI,QAAQ,kBAAkB;AAC7B,sCAAS,6BAA6B,OAAO,IAAI,KAAK,OAAO,GAAG,KAAK,MAAM;AAAA,QAC5E;AAAA,MACD;AAAA,IACD;AAAA,EACD;AACD;AASA,eAAsB,2BACrB,SACA,IACA,OACmB;AACnB,QAAM,SAAS,QAAQ;AAEvB,MAAI,CAAC,OAAO,wBAAwB,CAAC,OAAO,iBAAiB,CAAC,MAAM,QAAQ,OAAO,aAAa,GAAG;AAClG,WAAO;AAAA,EACR;AAEA,QAAM,gBAAgB,OAAO,cAAc,KAAK,CAAC,MAAW,EAAE,OAAO,EAAE,IAAI,KAAK,MAAM,EAAE;AACxF,MAAI,CAAC,eAAe;AACnB,WAAO;AAAA,EACR;AAEA,MAAI,MAAM,QAAQ,MAAM;AACvB,QAAI,CAAC,MAAM,KAAK;AACf,aAAO;AAAA,IACR;AACA,UAAM,sBAAsB,MAAM,uBAAuB,OAAO;AAEhE,QAAI,CAAC,qBAAqB;AACzB,UAAI,QAAQ,kBAAkB;AAC7B;AAAA,UACC,gCAAgC,cAAc,QAAQ,EAAE;AAAA,UACxD;AAAA,QACD;AAAA,MACD;AACA,aAAO;AAAA,IACR;AAEA,UAAM,mBAAmB,MAAM,QAAQ,kBAAc,+BAAU,cAAc,CAAC;AAC9E,UAAM,MAAM,KAAK,IAAI;AACrB,UAAM,iBAAgB,qDAAkB,OAAM;AAC9C,UAAM,qBAAoB,qDAAkB,SAAQ;AAEpD,QAAI,qBAAqB,MAAM,iBAAiB,OAAO,oBAAoB,OAAO,KAAM;AACvF,UAAI,QAAQ,kBAAkB;AAC7B;AAAA,UACC,gCAAgC,cAAc,QAAQ,EAAE;AAAA,UACxD;AAAA,QACD;AAAA,MACD;AACA,YAAM,QAAQ,aAAS,+BAAU,cAAc,GAAG,EAAE,KAAK,MAAM,KAAK,MAAM,CAAC;AAAA,IAC5E,OAAO;AACN,UAAI,QAAQ,kBAAkB;AAC7B;AAAA,UACC,gCAAgC,cAAc,QAAQ,EAAE;AAAA,UACxD;AAAA,QACD;AAAA,MACD;AAAA,IACD;AAAA,EACD;AAEA,SAAO;AACR;AAOA,eAAsB,wBAAwB,SAA0C;AACvF,QAAM,SAAS,QAAQ;AAGvB,MAAI,OAAO,qBAAqB,UAAU;AACzC;AAAA,EACD;AAEA,MAAI,OAAO,kBAAkB,MAAM;AAClC,QAAI,QAAQ,kBAAkB;AAC7B,kCAAS,qDAAqD,MAAM;AAAA,IACrE;AAEA,QAAI;AACH,YAAM,aAAa,SAAS,sCAAsC,KAAK,CAAC;AACxE,YAAM,QAAQ,2BAAuB,+BAAU,oCAAoC,GAAG,GAAG,IAAI;AAE7F,YAAM,aAAa,SAAS,0BAA0B,KAAK,CAAC;AAC5D,YAAM,QAAQ,2BAAuB,+BAAU,wBAAwB,GAAG,GAAG,IAAI;AAEjF,YAAM,aAAa,SAAS,2BAA2B,KAAK,EAAE;AAC9D,YAAM,QAAQ,2BAAuB,+BAAU,yBAAyB,GAAG,IAAI,IAAI;AAEnF,YAAM,UAAU;AAAA,QACf,EAAE,KAAK,2BAA2B,IAAI,IAAI;AAAA,QAC1C,EAAE,KAAK,yBAAyB,IAAI,IAAI;AAAA,QACxC,EAAE,KAAK,2BAA2B,IAAI,IAAI;AAAA,QAC1C,EAAE,KAAK,yBAAyB,IAAI,IAAI;AAAA,QACxC,EAAE,KAAK,2BAA2B,IAAI,IAAI;AAAA,QAC1C,EAAE,KAAK,yBAAyB,IAAI,IAAI;AAAA,QACxC,EAAE,KAAK,2BAA2B,IAAI,IAAI;AAAA,QAC1C,EAAE,KAAK,yBAAyB,IAAI,IAAI;AAAA,QACxC,EAAE,KAAK,2BAA2B,IAAI,IAAI;AAAA,QAC1C,EAAE,KAAK,yBAAyB,IAAI,IAAI;AAAA,MACzC;AAEA,iBAAW,KAAK,SAAS;AACxB,cAAM,aAAa,SAAS,EAAE,KAAK,EAAE,IAAI,CAAC;AAC1C,cAAM,QAAQ,2BAAuB,+BAAU,EAAE,GAAG,GAAG,SAAS,IAAI;AAAA,MACrE;AAAA,IACD,SAAS,KAAc;AACtB,YAAM,MAAM,eAAe,QAAQ,IAAI,UAAU,OAAO,GAAG;AAC3D,kCAAS,qCAAqC,GAAG,IAAI,OAAO;AAAA,IAC7D;AAAA,EACD;AACD;",
6
6
  "names": ["virtualDp"]
7
7
  }
package/io-package.json CHANGED
@@ -1,8 +1,47 @@
1
1
  {
2
2
  "common": {
3
3
  "name": "luxtronik2-controller",
4
- "version": "0.19.4",
4
+ "version": "0.20.0",
5
5
  "news": {
6
+ "0.20.0": {
7
+ "en": "*🚀 Features & Enhancements**\n\n**Automatic Firmware Update Check:** Added a background service to automatically check the official AIT download portal for new heat pump firmware updates.\n**Update Notifications:** Added a new configuration tab to set a custom cron schedule and enable optional Telegram notifications when a new firmware version is released.\n**New Update Datapoints:** Added `firmware_available`, `firmware_update_available`, and `firmware_changelog` to the system info tree to directly expose update states and release notes in ioBroker.\n**Manual Trigger Button:** Added a `check_firmware` button to manually initiate the update check process at any time.",
8
+ "de": "* 🚀 Funktionen & Erweiterungen**\n\n**Automatischer Firmware-Check: ** Es wurde ein Dienst hinzugefügt, der das offizielle AIT-Downloadportal nach neuen Wärmepumpen-Firmwareupdates sucht.\n**Updates: ** Ein neuer Konfigurationstab für Cron-Pläne und optionale Telegram-Benachrichtigungen bei Firmware-Versionen hinzugefügt.\n**Neue Update-Datenpunkte: ** `firmware_available`, `firmware_update_available` und `firmware_changelog` zum Systeminfobaum hinzugefügt, um Aktualisierungsstatus und Versionshinweise direkt in ioBroker anzuzeigen.\n**Manueller Auslöser: ** Es wurde eine `check_firmware`-Taste hinzugefügt, um das Update jederzeit manuell zu prüfen.",
9
+ "ru": "* 🚀 Функции и улучшения**\n\n**Автоматическая проверка обновления микропрограммного обеспечения: ** Добавлена фоновая служба для автоматической проверки обновлений прошивки тепловых насосов на официальном портале загрузок AIT.\n**Уведомления об обновлениях: ** Добавлена новая вкладка конфигурации, позволяющая настроить собственное расписание cron и включить дополнительные уведомления Telegram при выходе новой версии прошивки.\n**Новые точки обновления: ** Добавлены `firmware_available`, `firmware_update_available` и `firmware_changelog` в системное информационное дерево для непосредственного отображения состояний обновлений и примечаний к выпуску в IOBroker.\n**Кнопка ручного запуска: ** Добавлена кнопка `check_firmware` для ручного запуска процесса проверки обновлений в любое время.",
10
+ "pt": "* 🚀 Recursos e melhores**\n\n**Foi adicionado um serviço em segundo plano para verificar automaticamente o portal oficial de download da AIT para novas atualizações de firmware de bombas de calor.\n**Notificações de atualização: ** Foi adicionada uma nova guia para personalizar o cron e ativar as notificações opcionais do Telegram.\n**Novos pontos de dados: ** Foram adicionados `firmware_available`, `firmware_update_available` e `firmware_changelog` à árvore de dados do sistema para expor diretamente os estados e notas de lançamento no IOBroker.\n**Botão de acionamento manual: ** Adicionado o botão `check_firmware` para iniciar a atualização a qualquer momento.",
11
+ "nl": "* 🚀 Kenmerken en verbeteringen**\n\n**Automatische controle van de firmware-update: ** Een achtergrondservice toegevoegd om automatisch het officiële AIT-downloadportaal te controleren op nieuwe firmware-updates voor de warmtepomp.\n**Updatemeldingen: ** Een nieuw configuratietabblad toegevoegd om een aangepast cron-schema in te stellen en optionele Telegram-meldingen in te schakelen wanneer een nieuwe firmwareversie wordt uitgebracht.\n**Nieuwe updatedatapunten: ** `firmware_available`, `firmware_update_available` en `firmware_changelog` toegevoegd aan de systeeminformatiestructuur om de updatestatus en release-opmerkingen rechtstreeks in IOBroker weer te geven.\n**Handmatige triggerknop: ** Een `check_firmware'-knop toegevoegd om het updatecontroleproces op elk gewenst moment handmatig te starten.",
12
+ "fr": "* 🚀 Fonctionnalités et améliorations**\n\n**Vérification automatique du firmware :** Ajout d'un service d'arrière-plan permettant de consulter automatiquement les mises à jour du firmware des pompes à chaleur.\n**Notifications de mise à jour :** Ajout d'un nouvel onglet pour définir un calendrier Cron personnalisé et activer les notifications Telegram en cas de sortie du firmware.\n**Nouveaux points de mise à jour :** Ajout de « firmware_available », « firmware_update_available » et « firmware_changelog » à l'arborescence du système pour exposer directement l'état des mises à jour et les notes de version dans IOBroker.\n**Déclencheur manuel :** Ajout d'un bouton « check_firmware » pour lancer la vérification des mises à jour à tout moment.",
13
+ "it": "* 🚀 Funzioni e migliorie**\n\n**Controllo automatico del firmware: ** Aggiunto un servizio in background per il download ufficiale di AIT per le nuove pompe di calore.\n**Notifiche di aggiornamento: ** Aggiunta una nuova scheda per impostare un cron personalizzato e attivare le notifiche opzionali di Telegram.\n**Nuovi datapoint di aggiornamento: ** Aggiunti `firmware_available`, `firmware_update_available` e `firmware_changelog` al system info tree per esporre direttamente gli stati e le note di rilascio in IOBroker.\n**Aggiunto un pulsante `check_firmware` per avviare manualmente la verifica degli aggiornamenti in qualsiasi momento.",
14
+ "es": "* 🚀 Funciones y mejoras**\n\n**Comprobación automática del firmware: ** Se ha añadido un servicio en segundo plano para comprobar automáticamente el portal oficial de descargas de AIT.\n**Notificaciones de actualización: ** Se ha añadido una nueva pestaña de configuración para fijar un cron personalizado y recibir notificaciones de Telegram cuando salga una nueva versión del firmware.\n**Nuevos puntos de datos de actualización: ** Se han añadido «firmware_available» y «firmware_changelog» al árbol de información del sistema para ver directamente los estados de las actualizaciones y las notas de versión de ioBroker.\n**Botón de activación manual: ** Se ha añadido un botón `check_firmware` para iniciar el proceso de actualización en cualquier momento.",
15
+ "pl": "* 🚀 Funkcje i ulepszenia**\n\n**Automatyczne sprawdzanie aktualizacji oprogramowania układowego: ** Dodano usługę w tle, aby automatycznie sprawdzić oficjalny portal pobierania AIT pod kątem nowych aktualizacji oprogramowania układowego pompy ciepła.\n**Aktualizuj powiadomienia: ** Dodano nową kartę konfiguracji, aby ustawić niestandardowy harmonogram cron i włączyć opcjonalne powiadomienia Telegram po wydaniu nowej wersji oprogramowania układowego.\n**Nowe punkty danych aktualizacji: ** Dodano `firmware_available`, `firmware_update_available` i `firmware_changelog` do drzewa informacji systemowych, aby bezpośrednio wyświetlić stany aktualizacji i notatki o wydaniu w iOBroker.\n**Przycisk wyzwalania ręcznego: ** Dodano przycisk „check_firmware”, aby ręcznie rozpocząć proces sprawdzania aktualizacji w dowolnym momencie.",
16
+ "uk": "* 🚀 Функції та покращення**\n\n**Автоматична перевірка оновлення мікропрограми: ** Додано фонову службу для автоматичної перевірки офіційного порталу завантаження AIT на наявність нових оновлень мікропрограмного забезпечення теплового насоса.\n**Оновлення сповіщень: ** Додана нова вкладка конфігурації, щоб встановити власний розклад cron та увімкнути необов'язкові сповіщення Telegram при випуску нової версії мікропрограми.\n**Нові пункти оновлення: ** Додано `firmware_available`, `firmware_update_available` та `firmware_changelog` до системного інформаційного дерева для безпосереднього відображення станів оновлення та приміток до випуску в IObroker.\n**Кнопка запуску вручну: ** Додана кнопка `check_firmware` для ручного запуску процесу перевірки оновлення в будь-який час.",
17
+ "zh-cn": "* 🚀 功能和增强功能**\n\n**自动固件更新检查:** 添加了后台服务,可自动检查官方 AIT 下载门户是否有新的热泵固件更新。\n**更新通知:** 添加了新的配置选项卡,用于设置自定义 cron 时间表并在发布新固件版本时启用可选的 Telegram 通知。\n**新更新数据点:** 在系统信息树中添加了 “固件可用”、“firmware_update_available” 和 “firmware_changelog”,以直接在 IOBroker 中显示更新状态和发行说明。\n**手动触发按钮:** 添加了 “check_firmware” 按钮,可随时手动启动更新检查流程。"
18
+ },
19
+ "0.19.6": {
20
+ "en": "*🚀 Features & Enhancements**\n\n**Defrost Request Datapoint:** Added `Information.03_Outputs.DefrostRequest2` (Defrost request) to monitor the active defrosting request of the heat pump directly from the RAM telemetry (Index 235).\n\n**Defrost Request Datapoint:** Added `Information.03_Outputs.DefrostRequest` (Defrost request) to monitor the active defrosting request of the heat pump directly from the RAM telemetry (Index 234).",
21
+ "de": "* 🚀 Funktionen & Erweiterungen**\n\n**Abtauanfrage: ** `Information.03_outputs.defrostRequest2` (Abtauanfrage) hinzugefügt, um die aktive Abtauanfrage der Wärmepumpe direkt aus der RAM-Telemetrie zu überwachen (Index 235).\n\n**Abtauanfrage: ** `Information.03_outputs.defrostRequest` (Abtauanfrage) hinzugefügt, um die aktive Abtauanfrage der Wärmepumpe direkt aus der RAM-Telemetrie zu überwachen (Index 234).",
22
+ "ru": "* 🚀 Функции и улучшения**\n\n**Точка данных запроса на размораживание: ** Добавлена функция `Information.03_outputs.DefrostRequest2` (запрос на размораживание) для отслеживания активного запроса на размораживание теплового насоса непосредственно из телеметрии ОЗУ (индекс 235).\n\n**Точка данных запроса на размораживание: ** Добавлена функция `Information.03_outputs.DefrostRequest` (запрос на размораживание) для отслеживания активного запроса на размораживание теплового насоса непосредственно из телеметрии ОЗУ (индекс 234).",
23
+ "pt": "* 🚀 Recursos e melhores**\n\n**Ponto de dados de solicitação de degelo: ** Adicionado `information.03_outputs.defrostRequest2` para monitorar o pedido ativo de degelo da bomba de calor diretamente da telemetria RAM (Índice 235).\n\n**Ponto de dados de solicitação de degelo: ** Adicionado `information.03_outputs.defrostRequest` para monitorar a solicitação ativa de degelo da bomba de calor diretamente da telemetria RAM (Índice 234).",
24
+ "nl": "* 🚀 Kenmerken en verbeteringen**\n\n**Datapunt voor ontdooiaanvraag: ** `Information.03_Outputs.DefrostRequest2` toegevoegd om het actieve ontdooiverzoek van de warmtepomp rechtstreeks via de RAM-telemetrie te controleren (Index 235).\n\n**Datapunt voor ontdooiaanvraag: ** `Information.03_Outputs.DefrostRequest` (Ontdooiverzoek) toegevoegd om het actieve ontdooiverzoek van de warmtepomp rechtstreeks via de RAM-telemetrie te controleren (index 234).",
25
+ "fr": "* 🚀 Fonctionnalités et améliorations**\n\n**Point de données de demande de dégivrage :** Ajout de « Information.03_outputs.defrostRequest2 » pour suivre la demande de dégivrage active de la pompe à chaleur directement à partir de la télémétrie RAM (Index 235).\n\n**Point de données de demande de dégivrage :** Ajout de « Information.03_outputs.defrostRequest » pour suivre la demande de dégivrage active de la pompe à chaleur directement à partir de la télémétrie RAM (Index 234).",
26
+ "it": "* 🚀 Funzioni e migliorie**\n\n**Defrost Request Datapoint: ** Aggiunto `Information.03_outputs.defrostRequest2` per monitorare la richiesta di sbrinamento attiva della pompa di calore direttamente dalla telemetria RAM (Indice 235).\n\n**Defrost Request Datapoint: ** Aggiunto `Information.03_outputs.defrostRequest` per monitorare la richiesta di sbrinamento attiva della pompa di calore direttamente dalla telemetria RAM (Indice 234).",
27
+ "es": "* 🚀 Funciones y mejoras**\n\n**Punto de datos de solicitud de descongelación: ** Se ha añadido `Information.03_Outputs.defrostRequest2 para supervisar la solicitud de descongelación activa de la bomba de calor directamente desde la telemetría de la RAM (índice 235).\n\n**Punto de datos de solicitud de descongelación: ** Se ha añadido `Information.03_Outputs.defrostRequest` para supervisar la solicitud de descongelación activa de la bomba de calor directamente desde la telemetría de la RAM (índice 234).",
28
+ "pl": "* 🚀 Funkcje i ulepszenia**\n\n**Punkt danych żądania rozmrażania: ** Dodano `Information.03_Outputs.DefrostRequest2` (Żądanie rozmrażania) w celu monitorowania aktywnego żądania rozmrażania pompy ciepła bezpośrednio z telemetrii RAM (indeks 235).\n\n**Punkt danych żądania rozmrażania: ** Dodano `Information.03_Outputs.DefrostRequest` (żądanie rozmrażania) w celu monitorowania aktywnego żądania rozmrażania pompy ciepła bezpośrednio z telemetrii RAM (indeks 234).",
29
+ "uk": "* 🚀 Функції та покращення**\n\n**Запит на розморожування даних: ** Додано `information.03_outputs.defrostrequest2` (Запит на розморожування) для моніторингу активного запиту на розморожування теплового насоса безпосередньо з телеметрії оперативної пам'яті (Індекс 235).\n\n**Запит на розморожування даних: ** Додано `information.03_outputs.defrostRequest` (запит на розморожування) для моніторингу активного запиту на розморожування теплового насоса безпосередньо з телеметрії оперативної пам'яті (Індекс 234).",
30
+ "zh-cn": "* 🚀 功能和增强功能**\n\n**解冻请求数据点:** 添加了 `information.03_outputs.defrostRequest2`(解冻请求),以直接从内存遥测(索引 235)监控热泵的有效除霜请求。\n\n**解冻请求数据点:** 添加了 `information.03_outputs.defrostRequest`(解冻请求),以直接从内存遥测(索引 234)监控热泵的有效除霜请求。"
31
+ },
32
+ "0.19.5": {
33
+ "en": "*🚀 Features & Enhancements**\n\n**Defrost Request Datapoint:** Added `Information.03_Outputs.DefrostRequest` (Defrost request) to monitor the active defrosting request of the heat pump directly from the RAM telemetry (Index 234).",
34
+ "de": "* 🚀 Funktionen & Erweiterungen**\n\n**Abtauanfrage: ** `Information.03_outputs.defrostRequest` (Abtauanfrage) hinzugefügt, um die aktive Abtauanfrage der Wärmepumpe direkt aus der RAM-Telemetrie zu überwachen (Index 234).",
35
+ "ru": "* 🚀 Функции и улучшения**\n\n**Точка данных запроса на размораживание: ** Добавлена функция `Information.03_outputs.DefrostRequest` (запрос на размораживание) для отслеживания активного запроса на размораживание теплового насоса непосредственно из телеметрии ОЗУ (индекс 234).",
36
+ "pt": "* 🚀 Recursos e melhores**\n\n**Ponto de dados de solicitação de degelo: ** Adicionado `information.03_outputs.defrostRequest` para monitorar a solicitação ativa de degelo da bomba de calor diretamente da telemetria RAM (Índice 234).",
37
+ "nl": "* 🚀 Kenmerken en verbeteringen**\n\n**Datapunt voor ontdooiaanvraag: ** `Information.03_Outputs.DefrostRequest` (Ontdooiverzoek) toegevoegd om het actieve ontdooiverzoek van de warmtepomp rechtstreeks via de RAM-telemetrie te controleren (index 234).",
38
+ "fr": "* 🚀 Fonctionnalités et améliorations**\n\n**Point de données de demande de dégivrage :** Ajout de « Information.03_outputs.defrostRequest » pour suivre la demande de dégivrage active de la pompe à chaleur directement à partir de la télémétrie RAM (Index 234).",
39
+ "it": "* 🚀 Funzioni e migliorie**\n\n**Defrost Request Datapoint: ** Aggiunto `Information.03_outputs.defrostRequest` per monitorare la richiesta di sbrinamento attiva della pompa di calore direttamente dalla telemetria RAM (Indice 234).",
40
+ "es": "* 🚀 Funciones y mejoras**\n\n**Punto de datos de solicitud de descongelación: ** Se ha añadido `Information.03_Outputs.defrostRequest` para supervisar la solicitud de descongelación activa de la bomba de calor directamente desde la telemetría de la RAM (índice 234).",
41
+ "pl": "* 🚀 Funkcje i ulepszenia**\n\n**Punkt danych żądania rozmrażania: ** Dodano `Information.03_Outputs.DefrostRequest` (żądanie rozmrażania) w celu monitorowania aktywnego żądania rozmrażania pompy ciepła bezpośrednio z telemetrii RAM (indeks 234).",
42
+ "uk": "* 🚀 Функції та покращення**\n\n**Запит на розморожування даних: ** Додано `information.03_outputs.defrostRequest` (запит на розморожування) для моніторингу активного запиту на розморожування теплового насоса безпосередньо з телеметрії оперативної пам'яті (Індекс 234).",
43
+ "zh-cn": "* 🚀 功能和增强功能**\n\n**解冻请求数据点:** 添加了 `information.03_outputs.defrostRequest`(解冻请求),以直接从内存遥测(索引 234)监控热泵的有效除霜请求。"
44
+ },
6
45
  "0.19.4": {
7
46
  "en": "*🔧 Compatibility & Maintenance**\n\n**Hybrid Modbus Value Persistence:** Prevented native 3003 telemetry polling (EEPROM) from overwriting volatile parameters actively managed via Modbus TCP (RAM) in the ioBroker object tree.",
8
47
  "de": "* 🔧 Kompatibilität und Wartung**\n\n**Hybrid Modbus Value Persistence: ** Hat verhindert, dass native 3003-Telemetrieabfragen (EEPROM) im ioBroker-Objektbaum aktiv über Modbus TCP (RAM) verwaltet werden.",
@@ -54,45 +93,6 @@
54
93
  "pl": "* 📝 Dokumentacja i przegląd przewodnika**\n\n**Całkowite wyrównanie dokumentacji (`README.md` & `documentation/readme_de.md` & `documentation/readme_pl.md`) :**\nZrestrukturyzowano i zsynchronizowano zarówno niemiecką, jak i angielską dokumentację, aby dokładnie dopasować wszystki**11 kart konfiguracyjnych** interfejsu administratora w kolejności sekwencyjnej:\n**Architektura ochrony sprzętu: ** Dodano wyraźną sekcję wyjaśniającą ochronę przed odczytem przed zapisem („WritePumpSafe”), liczniki dziennych i całkowitych cykli flash oraz osłony awaryjnej oprogramowania sprzętowego dostawcy `.90`.\n**Rozwiązywanie problemów i kompatybilność ARM: ** Dodano dokumentację rozwiązywania problemów dotyczących nieszkodliwych ostrzeżeń o kompilacji „node-gyp\"/ „serialport”/„usocket” w systemach Raspberry Pi/ARM wraz ze wskazówkami krok po kroku dotyczącymi uruchamiania surowego skryptu diagnostycznego TCP („Test_Script.ts”).",
55
94
  "uk": "* 📝 Документація та капітальний ремонт**\n\n**Повне вирівнювання документації (`README.md` & `документація/readme_de.md` & `документація/readme_en.md`) :**\nРеструктуризовано та синхронізовано німецьку та англійську документацію, щоб точно відповідати всім**11 вкладкам конфігурації** інтерфейсу адміністратора в послідовному порядку:\n**Архітектура захисту апаратного забезпечення: ** Додано чіткий розділ, що пояснює захист від читання-до-запису (`WritePumpSafe`), щоденні та загальні лічильники циклу флеш-пам'яті, а також захист від аварійного захисту мікропрограми постачальника `.90`.\n**Усунення несправностей та сумісність ARM: ** Додана документація щодо усунення нешкідливих попереджень компіляції `node-gyp`/`serialport`/`usocket` на системах Raspberry Pi/ARM, поряд з покроковими вказівками для запуску необробленого скрипта діагностики TCP (`Test_script.ts`).",
56
95
  "zh-cn": "* 📝 文档和指南大修**\n\n**完全调整文档(`readme.md` 和 `documentation/readme_de.md` 和 `documentation/readme_en.md`):**\n重组并同步了德语和英语文档,以按顺序准确匹配管理界面的所有 **11 个配置选项卡**:\n**硬件保护架构:**添加了一个明确的章节,解释了写前读保护(`WritePumpSafe`)、每日和总闪存周期计数器以及供应商固件`.90`碰撞防护罩。\n**故障排除和 ARM 兼容性:** 添加了有关树莓派/ARM 系统上无害的 “node-gyp”/“serialport”/“usocket” 编译警告的故障排除文档,以及运行原始 TCP 诊断脚本(`Test_script.ts`)的分步指南。"
57
- },
58
- "0.19.0": {
59
- "en": "*🚀 Features & UX Improvements**\n\n**Hybrid Modbus TCP Support:** Introduced hybrid Modbus TCP support (`modbus-serial`) to write volatile parameters (e.g., target temperatures, heating curves, and coils/switches) directly into the Luxtronik RAM without causing EEPROM/flash memory wear, while continuing to read full telemetry via native port 8889/8214.\n**Smart ZIP Configuration:** Completely redesigned the Circulation Pump (ZIP) tab in the Admin UI. Introduced a dynamic dropdown (`zip_control_mode`) to intuitively switch between Internal Controller, External Actor (e.g., Shelly), and Modbus TCP (Coil 7), automatically hiding irrelevant settings to prevent misconfigurations.\n**ZIP Countdown Timer:** Added a new virtual datapoint (`Information.03_Outputs.Virtual_ZIP_Remaining_Time`) that displays the remaining runtime of the active circulation pump cycle in seconds.\n**Seamless Migration:** Implemented an automatic background migration routine to seamlessly upgrade existing user configurations to the new ZIP control logic without data loss.\n\n*🐛 Bugfixes**\n\n**Telegram Notifications UI:** Fixed a logic issue in `jsonConfig.json` where the Telegram warning message was incorrectly displayed even when instances were installed and available, and fixed the broken icon on the test button.\n\n*📝 Documentation**\n\n**ARM Installation Notes:** Added a troubleshooting note to the README clarifying that `usocket`, `serialport`, and `node-gyp` compilation errors on Raspberry Pi / ARM systems originate from optional serial dependencies and can be safely ignored.",
60
- "de": "* 🚀 Funktionen und UX-Verbesserungen**\n\n**Hybrid-Modbus-TCP-Unterstützung: ** Hybrid-Modbus-TCP (`Modbus-Seriell`), um flüchtige Parameter (z. B. Zieltemperaturen, Heizkurven und Spulen/Schalter) direkt in das Luxtronik-RAM zu schreiben, ohne EEPROM/Flash-Speicher zu belasten, und liest weiterhin die gesamte Telemetrie über den nativen Port 8889/8214.\n**Smart ZIP-Konfiguration: ** Der Tab Umwälzpumpe (ZIP) in der Admin-UI wurde komplett neu gestaltet. Es wurde ein dynamisches Dropdown (`zip_control_mode`) eingeführt, um intuitiv zwischen Internal Controller, External Actor (z. B. Shelly) und Modbus TCP (Coil 7) zu wechseln.\n**ZIP-Countdown-Timer: ** Ein neuer virtueller Datenpunkt (`Information.03_Outputs.Virtual_ZIP_Remaining_Time`) wurde hinzugefügt, der die Restlaufzeit der Umwälzpumpe in Sekunden anzeigt.\n**Reibungslose Migration: ** Eine automatische Hintergrundmigration ermöglicht ein nahtloses Upgrade auf die neue ZIP-Steuerlogik ohne Datenverlust.\n\n* 🐛 Bugfixes**\n\n**Telegram Notifications UI: ** Es wurde ein Logikproblem in `JSONConfig.json` behoben, bei dem die Telegram-Warnmeldung falsch angezeigt wurde, auch wenn Instances installiert und verfügbar waren.\n\n* 📝 Dokumente**\n\n**ARM-Installationshinweise: ** Der README-Datei wurde hinzugefügt, dass Kompilierungsfehler von `usocket`, `serialport` und `node-gyp` auf Raspberry Pi/ARM-Systemen von optionalen seriellen Abhängigkeiten herrühren und ignoriert werden können.",
61
- "ru": "* 🚀 Функции и улучшения пользовательского интерфейса**\n\n**Поддержка гибридного протокола Modbus TCP: ** Введена поддержка гибридного протокола Modbus TCP («modbus-serial»), позволяющая записывать изменчивые параметры (например, заданные температуры, кривые нагрева и катушки/переключатели) непосредственно в оперативную память Luxtronik без износа EEPROM/флэш-памяти и продолжая считывать полную телеметрию через собственный порт 8889/8214.\n**Умная конфигурация ZIP: ** Полностью переработана вкладка «Циркуляционный насос» (ZIP) в пользовательском интерфейсе администратора. Добавлен динамический выпадающий список (`zip_control_mode`), позволяющий интуитивно переключаться между внутренним контроллером, внешним актором (например, Shelly) и Modbus TCP (Coil 7), автоматически скрывая ненужные настройки для предотвращения неправильных конфигураций.\n**Таймер обратного отсчета ZIP: ** Добавлена новая виртуальная точка данных (`Information.03_outputs.virtual_zip_remaining_time`), которая отображает оставшееся время работы активного цикла циркуляционного насоса в секундах.\n**Простая миграция: ** Реализована автоматическая процедура фоновой миграции, позволяющая легко обновлять существующие пользовательские конфигурации до новой логики управления ZIP без потери данных.\n\n* 🐛 Исправления ошибок**\n\n**Пользовательский интерфейс уведомлений Telegram: ** Исправлена логическая ошибка в `JsonConfig.json`, из-за которой предупреждающее сообщение Telegram неправильно отображалось даже при установке и доступности экземпляров, а также исправлен сломанный значок на кнопке тестирования.\n\n* 📝 Документация**\n\n**Примечания по установке ARM: ** В README добавлено примечание по устранению неполадок, поясняющее, что ошибки компиляции «usocket», «serialport» и «node-gyp» в системах Raspberry Pi/ARM возникают из-за дополнительных последовательных зависимостей и их можно безопасно игнорировать.",
62
- "pt": "* 🚀 Recursos e melhorias UX**\n\n**Suporte Modbus TCP híbrido: ** Introduziu o suporte híbrido Modbus TCP (`modbus-serial`) para gravar parâmetros voláteis (por exemplo, temperaturas alvo, curvas de aquecimento e bobinas/interruptores) diretamente na RAM Luxtronik sem causar desgaste na memória EEPROM/Flash e continuar a ler telemetria completa via porta nativa 8889/8214.\n**Configuração Smart ZIP: ** A guia Bomba de Circulação (ZIP) foi totalmente redesenhada na IU do Admin. Introduziu um menu dinâmico (`zip_control_mode`) para alternar intuitivamente entre Controlador Interno, Ator Externo (ex., Shelly) e Modbus TCP (Coil 7), ocultando automaticamente configurações irrelevantes.\n**ZIP Countdown Timer: ** Foi adicionado um novo ponto de dados virtual (`information.03_outputs.virtual_zip_remaining_time`) que exibe o tempo restante do ciclo ativo da bomba em segundos.\n**Migração perfeita: ** Implementou uma rotina automática de migração em segundo plano para atualizar as configurações do usuário para a nova lógica de controle ZIP sem perda de dados.\n\n* 🐛 Correções**\n\n**UI de notificações do Telegram: ** Corrigido um problema lógico no `jsonConfig.json` em que o aviso do Telegram era exibido incorretamente mesmo com instâncias instaladas e disponível, e o ícone quebrado no botão de teste.\n\n* 📝 Documentação**\n\n**Notas de instalação do ARM: ** Uma nota de solução de problemas no README esclarece que os erros de compilação `usocket`, `serialport` e `node-gyp` nos sistemas Raspberry Pi/ARM se originam de dependências seriais opcionais e podem ser ignorados.",
63
- "nl": "* 🚀 Functies en UX-verbeteringen**\n\n**Hybrid Modbus TCP-ondersteuning: ** Introductie van hybride Modbus TCP-ondersteuning (`modbus-serie`) om vluchtige parameters (zoals doeltemperaturen, verwarmingscurven en spoelen/schakelaars) rechtstreeks naar het Luxtronik RAM-geheugen te schrijven zonder slijtage van het EEPROM/Flash-geheugen te veroorzaken, terwijl de volledige telemetrie via de oorspronkelijke poort 8889/8214 wordt doorgelezen.\n**Slimme ZIP-configuratie: ** Het tabblad Circulatiepomp (ZIP) in de beheerdersinterface volledig opnieuw ontworpen. Er is een dynamische dropdown (`zip_control_mode`) geïntroduceerd om intuïtief te schakelen tussen de interne controller, de externe actor (bijvoorbeeld Shelly) en Modbus TCP (Coil 7), waarbij irrelevante instellingen automatisch worden verborgen om verkeerde configuraties te voorkomen.\n**ZIP Countdown Timer: ** Een nieuw virtueel datapunt toegevoegd (`Information.03_Outputs.virtual_zip_remaining_time`) dat de resterende looptijd van de actieve circulatiepompcyclus in seconden weergeeft.\n**Naadloze migratie: ** Implementeerde een automatische routine voor achtergrondmigratie om bestaande gebruikersconfiguraties naadloos te upgraden naar de nieuwe ZIP-besturingslogica zonder gegevensverlies.\n\n* 🐛 Opgeloste fouten**\n\n**Gebruikersinterface voor Telegram-meldingen: ** Er is een logisch probleem opgelost in `JSONConfig.json` waarbij het Telegram-waarschuwingsbericht onjuist werd weergegeven, zelfs als er exemplaren waren geïnstalleerd en beschikbaar waren, en het kapotte pictogram op de testknop is verholpen.\n\n* 📝 Documentatie**\n\n**Aantekeningen bij de installatie van ARM: ** Een opmerking voor probleemoplossing toegevoegd aan de README waarin wordt verduidelijkt dat de compilatiefouten van `usocket`, `serialport` en `node-gyp` op Raspberry Pi-/ARM-systemen het gevolg zijn van optionele seriële afhankelijkheden en veilig kunnen worden genegeerd.",
64
- "fr": "* 🚀 Fonctionnalités et UX améliorées**\n\n**Support Modbus TCP hybride :** Introduction du support Modbus TCP hybride (« modbus-série ») pour écrire les paramètres volatils (températures cibles, courbes de chauffage, bobines et commutateurs) directement dans la RAM Luxtronik sans endommager les EEPROM ou la mémoire flash, tout en continuant à lire la télémétrie complète via le port natif 8889/8214.\n**Configuration ZIP intelligente :** L'onglet Circulation Pump (ZIP) de l'interface d'administration a été complètement repensé. Ajout d'un menu déroulant dynamique (« zip_control_mode ») permettant de basculer intuitivement entre Controller interne, External Actor (Shelly) et Modbus TCP (Coil 7), masquant automatiquement les paramètres inutiles pour éviter les erreurs de configuration.\n**Compte à rebours ZIP :** Ajout d'un nouveau point de données virtuel (« Information.03_outputs.virtual_ZIP_Remaining_Time ») qui affiche la durée restante du cycle actif de la pompe de circulation en secondes.\n**Migration fluide :** Mise en place d'une routine de migration automatique en arrière-plan pour passer facilement à la nouvelle logique de contrôle ZIP sans perte de données.\n\n* 🐛 Bugcorrects**\n\n**Interface des notifications Telegram :** Correction d'un problème logique dans `JSONConfig.json` qui affichait mal le message d'avertissement de Telegram alors que des instances étaient installées et disponibles, et a corrigé l'icône cassée sur le bouton de test.\n\n* 📝 Documentation**\n\n**Notes d'installation d'ARM :** Ajout d'une note de dépannage au README précisant que les erreurs de compilation « usocket », « serialport » et « node-gyp» sur les systèmes Raspberry Pi/ARM sont dues à des dépendances série facultatives et peuvent être ignorées en toute sécurité.",
65
- "it": "* 🚀 Funzioni e UX migliorate**\n\n**Supporto Modbus TCP ibrido (`modbus-serial`) per scrivere parametri volatili (ad es. temperature target, curve di riscaldamento e bobine/switch) direttamente nella RAM Luxtronik senza causare usura della memoria EEPROM/Flash, continuando a leggere la telemetria completa tramite la porta nativa 8889/8214.\n**Configurazione Smart ZIP: ** La scheda ZIP è stata completamente ridisegnata. Ha introdotto un menu a discesa dinamico (`zip_control_mode`) per passare intuitivamente da Internal Controller, External Actor (ad es. Shelly) e Modbus TCP (Bobina 7), nascondendo automaticamente le impostazioni irrilevanti per evitare errori.\n**ZIP Countdown Timer: ** Aggiunto un nuovo datapoint virtuale (`Information.03_outputs.VIRTUAL_ZIP_REMAINING_TIME`) che mostra l'autonomia residua del ciclo attivo in secondi.\n**Migrazione senza interruzioni: ** Implementata una routine automatica in background per aggiornare le configurazioni utente esistenti alla nuova logica ZIP senza perdita di dati.\n\n* 🐛 Bugfix**\n\n**Interfaccia utente di Telegram: ** Risolto un problema logico in `JsonConfig.json` in cui l'avviso di Telegram veniva visualizzato erroneamente anche se le istanze erano installate e disponibili e l'icona rotta sul pulsante di test.\n\n* 📝 Documenti**\n\n**Note di installazione ARM: ** Aggiunta una nota al README in cui si chiarisce che gli errori di compilazione uSocket, serialport e node-gyp sui sistemi Raspberry Pi/ARM derivano da dipendenze seriali opzionali e possono essere ignorati.",
66
- "es": "* 🚀 Funciones y mejoras en UX**\n\n**Soporte Modbus TCP híbrido: ** Introdujo el soporte Modbus TCP híbrido («serie modbus») para escribir parámetros volátiles (por ejemplo, temperaturas objetivo, curvas de calentamiento y bobinas o conmutadores) directamente en la RAM Luxtronik sin desgastar la EEPROM/Flash, sin dejar de leer la telemetría completa a través del puerto nativo 8889/8214.\n**Configuración ZIP inteligente: ** Se rediseñó por completo la pestaña Bomba de circulación (ZIP) de la UI de administrador. Introdujo un menú desplegable dinámico (`zip_control_mode`) para cambiar de forma intuitiva entre el controlador interno, el actor externo (por ejemplo, Shelly) y el Modbus TCP (Coil 7), ocultando automáticamente los ajustes irrelevantes para evitar errores de configuración.\n**Contador regresivo ZIP: ** Se ha añadido un nuevo punto de datos virtual (`Information.03_Outputs.Virtual_ZIP_REMAINING_TIME`) que muestra el tiempo de funcionamiento restante del ciclo activo de la bomba de circulación en segundos.\n**Migración fluida: ** Se implementó una rutina de migración automática en segundo plano para actualizar sin problemas las configuraciones de usuario actuales a la nueva lógica de control ZIP sin perder datos.\n\n* 🐛 Correcciones**\n\n**Interfaz de notificaciones de Telegram: ** Se ha corregido un problema lógico en `JSONConfig.json por el que el mensaje de aviso de Telegram aparecía mal incluso cuando había instancias instaladas y disponibles, y se ha corregido el icono roto del botón de prueba.\n\n* 📝 Documentación**\n\n**Notas de instalación de ARM: ** Se ha añadido una nota de solución de problemas al README en la que se aclara que los errores de compilación de «usocket», «puerto serie» y «node-gyp» en los sistemas Raspberry Pi/ARM se deben a dependencias en serie opcionales y se pueden ignorar de forma segura.",
67
- "pl": "* 🚀 Funkcje i ulepszenia UX**\n\n**Hybrid Modbus TCP Support: ** Wprowadzono hybrydową obsługę Modbus TCP („modbus serial”) do zapisywania parametrów zmiennych (np. docelowych temperatur, krzywych nagrzewania i cewki/przełączników) bezpośrednio do pamięci RAM Luxtronik bez powodowania zużycia pamięci EEPROM/flash, przy jednoczesnym kontynuowaniu odczytu pełnej telemetrii przez natywny port 8889/8214.\n**Inteligentna konfiguracja ZIP: ** Całkowicie przeprojektowana karta Pompa cyrkulacyjna (ZIP) w interfejsie administratora. Wprowadzono dynamiczne rozwijane menu („zip_control_mode”) do intuicyjnego przełączania między kontrolerem wewnętrznym, zewnętrznym aktorem (np. Shelly) i Modbus TCP (Coil 7), automatycznie ukrywając nieistotne ustawienia, aby zapobiec błędnym konfiguracjom.\n**ZIP Countdown Timer: ** Dodano nowy wirtualny punkt danych (`Information.03_Outputs.Virtual_ZIP_Remaining_Time`), który wyświetla pozostały czas działania aktywnego cyklu pompy obiegowej w sekundach.\n**Bezproblemowa migracja: ** Zaimplementowano automatyczną procedurę migracji w tle, aby bezproblemowo aktualizować istniejące konfiguracje użytkowników do nowej logiki sterowania ZIP bez utraty danych.\n\n* 🐛 Poprawki błędów**\n\n**Interfejs powiadomień telegramu: ** Naprawiono problem logiczny w `JSONConfig.json`, w którym komunikat ostrzegawczy Telegram był nieprawidłowo wyświetlany nawet wtedy, gdy instancje były zainstalowane i dostępne, i naprawiono uszkodzoną ikonę na przycisku testowym.\n\n* 📝 Dokumentacja**\n\n**Uwagi dotyczące instalacji ARM: ** Dodano do README informację dotyczącą rozwiązywania problemów wyjaśniającą, że błędy kompilacji „usocket”, „serialport” i „node-gyp\"w systemach Raspberry Pi/ARM pochodzą z opcjonalnych zależności szeregowych i można je bezpiecznie zignorować.",
68
- "uk": "* 🚀 Функції та вдосконалення UX**\n\n**Підтримка гібридного Modbus TCP: ** Введена гібридна підтримка Modbus TCP (`modbus-serial`) для запису мінливих параметрів (наприклад, цільових температур, кривих нагрівання та котушки/комутатори) безпосередньо в оперативну пам'ять Luxtronik без зносу EEPROM/флеш-пам'яті, продовжуючи читати повну телеметрію через рідний порт 8889/8214.\n**Конфігурація Smart ZIP: ** Повністю перероблена вкладка Циркуляційний насос (ZIP) в інтерфейсі адміністратора. Введено динамічний випадаючий список (`zip_control_mode`) для інтуїтивного перемикання між внутрішнім контролером, зовнішнім актором (наприклад, Shelly) та Modbus TCP (Coil 7), автоматично приховуючи невідповідні налаштування, щоб запобігти неправильним конфігураціям.\n**Таймер зворотного відліку ZIP: ** Додано новий віртуальний пункт даних (`information.03_outputs.virtual_zip_ing_time`), який відображає решту часу роботи циклу активного циркуляційного насоса в секундах.\n**Безшовна міграція: ** Реалізовано автоматичну процедуру фонової міграції для безперешкодного оновлення існуючих конфігурацій користувачів до нової логіки керування ZIP без втрати даних.\n\n* 🐛 Виправлення вадь**\n\n**Інтерфейс сповіщень Telegram: ** Виправлено логічну проблему в `JsonConfig.json`, коли попереджувальне повідомлення Telegram неправильно відображалося, навіть коли екземпляри були встановлені та доступні, та виправлено зламану піктограму на тестовій кнопці.\n\n* 📝 Документація**\n\n**Примітки щодо встановлення ARM: ** Додано примітку щодо усунення несправностей до README, яка пояснює, що помилки компіляції `usocket`, `serialport` та `node-gyp` у системах Raspberry Pi/ARM походять від необов'язкових послідовних залежностей і можуть бути безпечно ігноровані.",
69
- "zh-cn": "* 🚀 功能和用户体验改进**\n\n**混合 Modbus TCP 支持:** 引入了混合 Modbus TCP 支持(“modbus-serial”),可在不导致 EEPROM/闪存磨损的情况下将易失性参数(例如目标温度、加热曲线和线圈/开关)直接写入立讯内存,同时继续通过原生端口 8889/8214 读取完整的遥测数据。\n**智能 ZIP 配置:** 完全重新设计了管理员用户界面中的 “循环泵 (ZIP)” 选项卡。引入了动态下拉菜单(`zip_control_mode`),可以直观地在内部控制器、外部控制器(例如Shelly)和Modbus TCP(线圈7)之间切换,自动隐藏无关的设置以防止错误配置。\n**ZIP 倒计时器:** 添加了一个新的虚拟数据点(`Information.03_outputs.Virtual_ZIP_remaining_Time`),该数据点以秒为单位显示活跃循环泵周期的剩余运行时间。\n**无缝迁移:**实现了自动后台迁移例程,将现有用户配置无缝升级到新的ZIP控制逻辑,而不会丢失数据。\n\n* 🐛 错误修复**\n\n**电报通知用户界面:** 修复了 `jsonConfig.json` 中的一个逻辑问题,即即使实例已安装且可用,电报警告消息也无法正确显示,并修复了测试按钮上损坏的图标。\n\n* 📝 文档**\n\n**ARM 安装说明:** 在自述文件中添加了故障排除说明,澄清了树莓派/ARM 系统上的 “usocket”、“serialport” 和 “node-gy” 编译错误源于可选的串行依赖关系,可以放心地忽略。"
70
- },
71
- "0.18.2": {
72
- "en": "*🔧 Maintenance & Repository Compliance**\n\n**Core Dependency Update:** Raised minimum required `js-controller` dependency to `>=7.0.7` in `io-package.json` to ensure compatibility with modern ioBroker environments (resolves E1057).\n**Full i18n Localization for Admin UI:** Added complete multi-language label sets (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) for COP power and thermal source selection dropdowns in `jsonConfig.json` (resolves W5611).\n**Package News Cleanup:** Removed unreleased intermediate tags (`0.17.0`, `0.16.1`) from `common.news` in `io-package.json` to align strictly with published NPM releases (resolves W2004).\n**CI/CD Security Compliance:** Updated GitHub auto-merge workflows for Dependabot to adhere to GitHub's updated `pull_request_target` execution policies (PR #90 / Issue #89).\n**Code Modernization:** Migrated built-in Node.js module imports to use the explicit `node:` protocol prefix (e.g. `node:fs`, `node:path`).",
73
- "de": "* 🔧 Wartung und Repository-Konformität**\n\n**Update zur Kernabhängigkeit: ** Die Mindestabhängigkeit von `js-controller`` in `io-package.json` wurde auf `>=7.0.7` erhöht, um mit modernen ioBroker-Umgebungen kompatibel zu sein (löst E1057).\n**Vollständige i18n-Lokalisierung für Admin-UI: ** Vollständige mehrsprachige Labelsets (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) in `JSONConfig.json` hinzugefügt (löst W5611).\n**Package News Cleanup: ** Unveröffentlichte Zwischen-Tags (`0.17.0`, `0.16.1`) von `common.news` in `io-package.json` entfernt, um sie genau an NPM-Releases anzupassen (löst W2004).\n**CI/CD-Sicherheit: ** GitHub-Auto-Merge-Workflows für Dependabot wurden an GitHubs neue `pull_request_target`-Regeln angepasst (PR #90/Issue #89).\n**Code-Modernisierung: ** Integrierte Node.js Modulimporte auf das explizite `node: `-Protokollpräfix migriert (z. B. `node:fs`, `node:path`).",
74
- "ru": "* 🔧 Техническое обслуживание и соответствие требованиям репозитория**\n\n**Обновление основных зависимостей: ** Минимальная требуемая зависимость `js-controller` увеличена до `>=7.0.7` в `io-package.json` для обеспечения совместимости с современными средами IOBroker (исправлено E1057).\n**Полная локализация i18n для пользовательского интерфейса администратора: ** Добавлены полные многоязычные наборы меток (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) для выпадающих списков выбора питания и источника тепла COP в `JsonConfig.json` (разрешение W5611).\n**Очистка новостей о пакетах: ** Удалены неопубликованные промежуточные теги (`0.17.0`, `0.16.1») из `common.news` в `io-package.json`, чтобы строго соответствовать опубликованным выпускам NPM (резолюция W2004).\n**Соответствие требованиям безопасности CI/CD: ** Обновлены рабочие процессы автоматического объединения GitHub для Dependabot в соответствии с обновленными политиками выполнения GitHub `pull_request_target` (PR #90/Issue #89).\n**Модернизация кода: ** Перемещен импорт встроенного модуля Node.js для использования явного префикса протокола `node:` (например, `node:fs`, `node:path`).",
75
- "pt": "* 🔧 Manutenção e conformidade do repositório**\n\n**Atualização de dependência básica: ** Aumentou a dependência mínima de `js-controller` para `>=7.0.7` em `io-package.json` para garantir compatibilidade com ambientes IOBroker modernos (resolve E1057).\n**Localização i18n completa para Admin UI: ** Foram adicionados rótulos completos em vários idiomas (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) para seleção de fonte térmica e de energia COP em `JSONConfig.json` (resolve W5611).\n**Limpeza de notícias do pacote: ** Removemos tags intermediárias inéditas (`0.17.0`, `0.16.1`) de `common.news` em `io-package.json` para alinhar com versões publicadas do NPM (resolve W2004).\n**Conformidade de segurança CI/CD: ** Fluxos de trabalho de mesclagem automática do GitHub para Dependabot aderir às políticas de execução `pull_request_target` do GitHub (PR #90/Issue #89).\n**Modernização de código: ** Importações do módulo Node.js embutido migrado para usar o prefixo explícito `node: `(ex: `node:fs`, `node:path`).",
76
- "nl": "* 🔧 Onderhoud en naleving van de opslagplaats**\n\n**Core-afhankelijkheidsupdate: ** Verhoogd de minimaal vereiste `js-controller` afhankelijkheid naar `>=7.0.7` in `io-package.json` om compatibiliteit met moderne IOBroker-omgevingen te garanderen (lost E1057 op).\n**Volledige i18n-lokalisatie voor Admin UI: ** Complete meertalige labelsets toegevoegd (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) voor keuzelijsten voor COP-voeding en thermische bronselectie in `JSONConfig.json` (lost W5611 op).\n**Package News Cleanup: ** Niet eerder uitgebrachte tussentijdse tags (`0.17.0`, `0.16.1`) verwijderd uit `common.news` in `io-package.json` om ze strikt aan te passen aan gepubliceerde NPM-releases (lost W2004 op).\n**Conformiteit met CI/CD-beveiliging: ** Bijgewerkte GitHub-workflows voor automatische samenvoeging zodat Dependabot kan voldoen aan het bijgewerkte uitvoeringsbeleid van `pull_request_target` van GitHub (PR #90 /Issue #89).\n**Modernisering van de code: ** De ingebouwde module Node.js wordt geïmporteerd om het expliciete protocolvoorvoegsel „node:” te gebruiken (bijv. `node:fs`, `node:path`).",
77
- "fr": "* 🔧 Maintenance et conformité du dépôt**\n\n**Core Dependency Update :** Augmentation de la dépendance minimale requise à « js-controller » à « >=7.0.7 » dans « io-package.json » afin de garantir la compatibilité avec les environnements IObroker modernes (résolution E1057).\n**Localisation complète d'i18n pour l'interface d'administration :** Ajout de jeux d'étiquettes multilingues complets (« ru », « pt », « nl », « fr », « it », « es », « pl », « uk », « zh-cn ») pour les listes déroulantes de sélection de l'alimentation COP et des sources thermiques dans « JSONConfig.json » (résout W5611).\n**Package News Cleanup :** Suppression des tags intermédiaires inédits (« 0.17.0 », « 0.16.1 ») de « common.news » dans « io-package.json » pour s'aligner strictement sur les versions publiées de NPM (résout W2004).\n**Conformité à la sécurité CI/CD :** Mise à jour des flux de fusion automatique de GitHub pour que Dependabot respecte les règles d'exécution « pull_request_target » de GitHub (PR #90/Issue #89).\n**Modernisation du code :** Le module Node.js intégré a migré pour utiliser le préfixe explicite du protocole node : (par exemple node:fs, node:path).",
78
- "it": "* 🔧 Manutenzione e conformità del deposito**\n\n**Core Dependency Update: ** Aumentata la dipendenza minima `js-controller` a `>=7.0.7` in `io-package.json` per garantire la compatibilità con i moderni ambienti IOBroker (risolve E1057).\n**Localizzazione i18n completa per l'interfaccia utente di amministrazione: ** Aggiunti set completi di etichette multilingue (ru`, `pt`, `nl`, fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) per i menu COP power e thermal source in `JSONConfig.json` (risolve W5611).\n**Package News Cleanup: ** Rimossi i tag intermedi inediti (`0.17.0`, `0.16.1`) da `common.news` in `io-package.json` per allinearli alle versioni NPM pubblicate (risolve W2004).\n**Conformità alla sicurezza CI/CD: ** Flussi di lavoro di fusione automatica di GitHub aggiornati per aderire alle policy di esecuzione `pull_request_target` di GitHub (PR #90/Issue #89).\n**Modernizzazione del codice: ** Il modulo Node.js integrato migrato utilizza il prefisso esplicito `node: `(es. `node:fs`, `node:path`).",
79
- "es": "* 🔧 Mantenimiento y cumplimiento del repositorio**\n\n**Actualización de dependencia básica: ** Se elevó la dependencia mínima requerida de «js-controller» a >=7.0.7 en «io-package.json» para garantizar la compatibilidad con los entornos modernos de IOBroker (resuelve el E1057).\n**Localización completa del i18n para la interfaz de usuario de administrador: ** Se han añadido conjuntos completos de etiquetas multilingües (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) para los menús desplegables de potencia y fuentes térmicas de COP en `JsonConfig.json` (resuelve el W5611).\n**Package News Cleanup: ** Se han eliminado las etiquetas intermedias inéditas (0.17.0, 0.16.1) de common.news en io-package.json para alinearlas estrictamente con las versiones publicadas de NPM (resuelve W2004).\n**Cumplimiento de seguridad de CI/CD: ** Se han actualizado los flujos de trabajo de fusión automática de GitHub para que el Dependabot cumpla con las políticas de ejecución de «pull_request_target» de GitHub (PR #90/Issue #89).\n**Modernización del código: ** Se migraron las importaciones del módulo Node.js integrado para usar el prefijo de protocolo `node: `explícito (p. ej., `node:fs`, `node:path).",
80
- "pl": "* 🔧 Zgodność z konserwacją i repozytorium**\n\n**Aktualizacja podstawowej zależności: ** Podniesiono minimalną wymaganą zależność `js-controller` do `>=7.0.7` w `io-package.json` w celu zapewnienia zgodności z nowoczesnymi środowiskami ioBroker (rozwiązuje E1057).\n**Pełna lokalizacja i18n dla interfejsu administratora: ** Dodano kompletne wielojęzyczne zestawy etykiet (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) dla menu rozwijanego wyboru zasilania COP i źródła termicznego w `JSONConfig.json` (rozwiązuje W5611).\n**Czyszczenie wiadomości pakietu: ** Usunięto niepublikowane znaczniki pośrednie (`0.17.0`, `0.16.1`) z `common.news` w `io-package.json` w celu ścisłego dopasowania do opublikowanych wersji NPM (rozwiązuje W2004).\n**Zgodność z zabezpieczeniami CI/CD: ** Zaktualizowano przepływy pracy automatycznego scalania GitHub dla Dependabot, aby były zgodne ze zaktualizowanymi zasadami wykonania `pull_request_target` GitHub (PR #90/Issue #89).\n**Modernizacja kodu: ** Migrowany wbudowany import modułu Node.js w celu użycia jawnego prefiksu protokołu `node: `(np. `node:fs`, `node:path`).",
81
- "uk": "* 🔧 Технічне обслуговування та відповідність сховища**\n\n**Оновлення залежності ядра: ** Підвищено мінімальну необхідну залежність `js-controller` до `>=7.0.7` у `io-package.json` для забезпечення сумісності з сучасними середовищами IObroker (вирішує E1057).\n**Повна локалізація i18n для інтерфейсу адміністратора: ** Додано повні багатомовні набори міток (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) для випадаючих списків вибору живлення COP та теплового джерела в `JsonConfig.json` (вирішує W5611).\n**Очищення новин пакета: ** Видалено невипущені проміжні теги (`0.17.0`, `0.16.1`) з `common.news` у `io-package.json` для суворого узгодження з опублікованими випусками NPM (вирішує W2004).\n**Відповідність безпеки CI/CD: ** Оновлені робочі процеси автоматичного об'єднання GitHub для Dependabot, щоб дотримуватися оновленої політики виконання GitHub `pull_request_target` (PR #90/Випуск #89).\n**Модернізація коду: ** Перенесено імпорт вбудованого модуля Node.js для використання явного префікса протоколу `node: `(наприклад, `node:fs`, `node:path`).",
82
- "zh-cn": "* 🔧 维护和存储库合规性**\n\n**核心依赖关系更新:** 在 io-package.json 中将 “js-controller” 所需的最低依赖关系提高到 `>=7.0.7`,以确保与现代 IOBroker 环境兼容(已解决 E1057)。\n**管理员用户界面的完整 i18n 本地化:** 在 `jsonConfig.json` 中为 COP 电源和热源选择下拉菜单添加了完整的多语言标签集(`ru`、`pt`、`nl`、`fr`、`it`、`es`、`pl`、`uk`、`zh-cn`)(已解决 W5611)。\n**Package News Cleanup:** 从 `io-package.json` 的 `common.news` 中删除了未发布的中间标签(`0.17.0`,`0.16.1`),以严格与已发布的 NPM 版本保持一致(已解决 W2004)。\n**CI/CD 安全合规性:** 更新了 Dependabot 的 GitHub 自动合并工作流程,以遵守 GitHub 更新后的 `pull_request_target` 执行政策(PR #90/问题 #89)。\n**代码现代化:** 迁移了内置 Node.js 模块导入,以使用明确的 `node: `协议前缀(例如 `node: fs`、`node: path`)。"
83
- },
84
- "0.18.1": {
85
- "en": "*🐛 Bugfixes**\n\n**COP Database Persistence:** Fixed a critical bug in the object manager's cleanup routine (`cleanupStates`). The internal database folder (`hidden.cop_buckets`) was missing from the exclusion list and got aggressively deleted upon every adapter restart, resulting in wiped COP histories and `(null)` values. The hidden states are now strictly protected against the cleanup process, ensuring long-term persistence for energy calculations.",
86
- "de": "* 🐛 Bugfixes**\n\n**COP Database Persistence: ** Kritischer Bug im Objektmanager behoben (`CleanupStates`). Der interne Datenbankordner (`hidden.cop_buckets`) fehlte in der Ausschlussliste und wurde bei jedem Adapter-Neustart gelöscht, wodurch COP-Historien und `(Null)` Werte gelöscht wurden. Die versteckten Staaten sind jetzt strikt vor der Säuberung geschützt, was Energieberechnungen langfristig ermöglicht.",
87
- "ru": "* 🐛 Исправления ошибок**\n\n**Сохранность базы данных COP: ** Исправлена критическая ошибка в процедуре очистки диспетчера объектов (`CleanupStates`). Внутренняя папка базы данных (`hidden.cop_buckets`) отсутствовала в списке исключений и активно удалялась при каждом перезапуске адаптера, в результате чего история COP и значения «(null)» стирались. Скрытые состояния теперь строго защищены от процесса очистки, что обеспечивает долгосрочную сохранность расчетов энергопотребления.",
88
- "pt": "* 🐛 Correções**\n\n**COP Database Persistence: ** Corrigido um bug crítico na rotina de limpeza do gerenciador de objetos. A pasta interna do banco de dados (`hidden.cop_buckets`) não aparecia na lista de exclusão e era apagada a cada reinicialização do adaptador, apagando históricos COP e valores `(nulos)`. Os estados ocultos agora são protegidos contra o processo de limpeza, garantindo a durabilidade dos cálculos de energia.",
89
- "nl": "* 🐛 Opgeloste fouten**\n\n**PERSISTENTIE VAN DE COP-database: ** Er is een kritieke fout opgelost in de opruimingsroutine van de objectbeheerder (`CleanUpStates`). De interne databasemap (`hidden.cop_buckets`) ontbrak in de lijst met uitsluitingen en werd agressief verwijderd bij elke herstart van de adapter, wat resulteerde in gewiste COP-geschiedenissen en waarden van `(null)`. De verborgen staten zijn nu strikt beschermd tegen het opruimingsproces, waardoor energieberekeningen op lange termijn kunnen worden volgehouden.",
90
- "fr": "* 🐛 Bugcorrects**\n\n**Persistance de la base de données COP :** Correction d'un bug dans la routine de nettoyage du gestionnaire d'objets. Le dossier interne de la base de données (« hidden.cop_buckets ») ne figurait pas dans la liste d'exclusion et a été supprimé à chaque redémarrage de l'adaptateur, effaçant ainsi l'historique des COP et les valeurs « (null) ». Les états cachés sont désormais strictement protégés contre le processus de nettoyage, ce qui garantit la pérennité des calculs énergétiques.",
91
- "it": "* 🐛 Bugfix**\n\n**Persistenza del database COP: ** Risolto un bug critico nella routine di pulizia del gestore oggetti La cartella interna del database (`hidden.cop_buckets`) mancava dall'elenco delle esclusioni e veniva eliminata a ogni riavvio dell'adattatore, cancellando la cronologia COP e i valori `null`. Gli stati nascosti sono ora protetti dal processo di pulizia, garantendo calcoli energetici duraturi.",
92
- "es": "* 🐛 Correcciones**\n\n**Persistencia de la base de datos COP: ** Se ha corregido un error crítico en la rutina de limpieza del gestor de objetos. La carpeta interna de la base de datos (`hidden.cop_buckets`) no figuraba en la lista de exclusiones y se eliminaba de forma agresiva cada vez que se reiniciaba el adaptador, lo que borraba los historiales de COP y los valores `(null)`. Los estados ocultos están ahora estrictamente protegidos contra el proceso de limpieza, lo que garantiza la persistencia a largo plazo de los cálculos de energía.",
93
- "pl": "* 🐛 Poprawki błędów**\n\n**Trwałość bazy danych COP: ** Naprawiono krytyczny błąd w procedurze czyszczenia menedżera obiektów (`CleanupStates`). Wewnętrzny folder bazy danych (`hidden.cop_buckets`) brakował na liście wykluczeń i był agresywnie usuwany przy każdym ponownym uruchomieniu adaptera, co skutkowało wyczyszczonymi historiami COP i wartościami `(null)`. Ukryte stany są teraz ściśle chronione przed procesem oczyszczania, zapewniając długoterminową trwałość obliczeń energii.",
94
- "uk": "* 🐛 Виправлення вадь**\n\n**Постійність бази даних COP: ** Виправлена критична помилка в процедурі очищення менеджера об'єктів (`CleanupState`). Внутрішня тека бази даних (`hidden.cop_buckets`) була відсутня у списку виключень і була агресивно видалена при кожному перезапуску адаптера, що призвело до видалення історій COP та значень `(null)`. Приховані стани тепер суворо захищені від процесу очищення, забезпечуючи довгострокову стійкість для розрахунків енергії.",
95
- "zh-cn": "* 🐛 错误修复**\n\n**COP 数据库持久性:** 修复了对象管理器清理例程 (`cleanupStates`) 中的一个严重错误。内部数据库文件夹(`hidden.cop_buckets`)不在例外列表中,并且在每次适配器重启时都会被大量删除,从而导致 COP 历史记录和 `(空)`值被擦除。现在,隐藏状态受到严格保护,免受清理过程的影响,从而确保了能量计算的长期持续性。"
96
96
  }
97
97
  },
98
98
  "titleLang": {
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "iobroker.luxtronik2-controller",
3
- "version": "0.19.4",
3
+ "version": "0.20.0",
4
4
  "description": "Zugriff und Steuerung von Wärmepumpen mit einer Luxtronik 2.x Steuereinheit",
5
5
  "author": {
6
6
  "name": "TbsJah",