iobroker.luxtronik2-controller 0.18.1 → 0.19.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/io-package.json CHANGED
@@ -1,8 +1,34 @@
1
1
  {
2
2
  "common": {
3
3
  "name": "luxtronik2-controller",
4
- "version": "0.18.1",
4
+ "version": "0.19.0",
5
5
  "news": {
6
+ "0.19.0": {
7
+ "en": "*🚀 Features & UX Improvements**\n\n**Hybrid Modbus TCP Support:** Introduced hybrid Modbus TCP support (`modbus-serial`) to write volatile parameters (e.g., target temperatures, heating curves, and coils/switches) directly into the Luxtronik RAM without causing EEPROM/flash memory wear, while continuing to read full telemetry via native port 8889/8214.\n**Smart ZIP Configuration:** Completely redesigned the Circulation Pump (ZIP) tab in the Admin UI. Introduced a dynamic dropdown (`zip_control_mode`) to intuitively switch between Internal Controller, External Actor (e.g., Shelly), and Modbus TCP (Coil 7), automatically hiding irrelevant settings to prevent misconfigurations.\n**ZIP Countdown Timer:** Added a new virtual datapoint (`Information.03_Outputs.Virtual_ZIP_Remaining_Time`) that displays the remaining runtime of the active circulation pump cycle in seconds.\n**Seamless Migration:** Implemented an automatic background migration routine to seamlessly upgrade existing user configurations to the new ZIP control logic without data loss.\n\n*🐛 Bugfixes**\n\n**Telegram Notifications UI:** Fixed a logic issue in `jsonConfig.json` where the Telegram warning message was incorrectly displayed even when instances were installed and available, and fixed the broken icon on the test button.\n\n*📝 Documentation**\n\n**ARM Installation Notes:** Added a troubleshooting note to the README clarifying that `usocket`, `serialport`, and `node-gyp` compilation errors on Raspberry Pi / ARM systems originate from optional serial dependencies and can be safely ignored.",
8
+ "de": "* 🚀 Funktionen und UX-Verbesserungen**\n\n**Hybrid-Modbus-TCP-Unterstützung: ** Hybrid-Modbus-TCP (`Modbus-Seriell`), um flüchtige Parameter (z. B. Zieltemperaturen, Heizkurven und Spulen/Schalter) direkt in das Luxtronik-RAM zu schreiben, ohne EEPROM/Flash-Speicher zu belasten, und liest weiterhin die gesamte Telemetrie über den nativen Port 8889/8214.\n**Smart ZIP-Konfiguration: ** Der Tab Umwälzpumpe (ZIP) in der Admin-UI wurde komplett neu gestaltet. Es wurde ein dynamisches Dropdown (`zip_control_mode`) eingeführt, um intuitiv zwischen Internal Controller, External Actor (z. B. Shelly) und Modbus TCP (Coil 7) zu wechseln.\n**ZIP-Countdown-Timer: ** Ein neuer virtueller Datenpunkt (`Information.03_Outputs.Virtual_ZIP_Remaining_Time`) wurde hinzugefügt, der die Restlaufzeit der Umwälzpumpe in Sekunden anzeigt.\n**Reibungslose Migration: ** Eine automatische Hintergrundmigration ermöglicht ein nahtloses Upgrade auf die neue ZIP-Steuerlogik ohne Datenverlust.\n\n* 🐛 Bugfixes**\n\n**Telegram Notifications UI: ** Es wurde ein Logikproblem in `JSONConfig.json` behoben, bei dem die Telegram-Warnmeldung falsch angezeigt wurde, auch wenn Instances installiert und verfügbar waren.\n\n* 📝 Dokumente**\n\n**ARM-Installationshinweise: ** Der README-Datei wurde hinzugefügt, dass Kompilierungsfehler von `usocket`, `serialport` und `node-gyp` auf Raspberry Pi/ARM-Systemen von optionalen seriellen Abhängigkeiten herrühren und ignoriert werden können.",
9
+ "ru": "* 🚀 Функции и улучшения пользовательского интерфейса**\n\n**Поддержка гибридного протокола Modbus TCP: ** Введена поддержка гибридного протокола Modbus TCP («modbus-serial»), позволяющая записывать изменчивые параметры (например, заданные температуры, кривые нагрева и катушки/переключатели) непосредственно в оперативную память Luxtronik без износа EEPROM/флэш-памяти и продолжая считывать полную телеметрию через собственный порт 8889/8214.\n**Умная конфигурация ZIP: ** Полностью переработана вкладка «Циркуляционный насос» (ZIP) в пользовательском интерфейсе администратора. Добавлен динамический выпадающий список (`zip_control_mode`), позволяющий интуитивно переключаться между внутренним контроллером, внешним актором (например, Shelly) и Modbus TCP (Coil 7), автоматически скрывая ненужные настройки для предотвращения неправильных конфигураций.\n**Таймер обратного отсчета ZIP: ** Добавлена новая виртуальная точка данных (`Information.03_outputs.virtual_zip_remaining_time`), которая отображает оставшееся время работы активного цикла циркуляционного насоса в секундах.\n**Простая миграция: ** Реализована автоматическая процедура фоновой миграции, позволяющая легко обновлять существующие пользовательские конфигурации до новой логики управления ZIP без потери данных.\n\n* 🐛 Исправления ошибок**\n\n**Пользовательский интерфейс уведомлений Telegram: ** Исправлена логическая ошибка в `JsonConfig.json`, из-за которой предупреждающее сообщение Telegram неправильно отображалось даже при установке и доступности экземпляров, а также исправлен сломанный значок на кнопке тестирования.\n\n* 📝 Документация**\n\n**Примечания по установке ARM: ** В README добавлено примечание по устранению неполадок, поясняющее, что ошибки компиляции «usocket», «serialport» и «node-gyp» в системах Raspberry Pi/ARM возникают из-за дополнительных последовательных зависимостей и их можно безопасно игнорировать.",
10
+ "pt": "* 🚀 Recursos e melhorias UX**\n\n**Suporte Modbus TCP híbrido: ** Introduziu o suporte híbrido Modbus TCP (`modbus-serial`) para gravar parâmetros voláteis (por exemplo, temperaturas alvo, curvas de aquecimento e bobinas/interruptores) diretamente na RAM Luxtronik sem causar desgaste na memória EEPROM/Flash e continuar a ler telemetria completa via porta nativa 8889/8214.\n**Configuração Smart ZIP: ** A guia Bomba de Circulação (ZIP) foi totalmente redesenhada na IU do Admin. Introduziu um menu dinâmico (`zip_control_mode`) para alternar intuitivamente entre Controlador Interno, Ator Externo (ex., Shelly) e Modbus TCP (Coil 7), ocultando automaticamente configurações irrelevantes.\n**ZIP Countdown Timer: ** Foi adicionado um novo ponto de dados virtual (`information.03_outputs.virtual_zip_remaining_time`) que exibe o tempo restante do ciclo ativo da bomba em segundos.\n**Migração perfeita: ** Implementou uma rotina automática de migração em segundo plano para atualizar as configurações do usuário para a nova lógica de controle ZIP sem perda de dados.\n\n* 🐛 Correções**\n\n**UI de notificações do Telegram: ** Corrigido um problema lógico no `jsonConfig.json` em que o aviso do Telegram era exibido incorretamente mesmo com instâncias instaladas e disponível, e o ícone quebrado no botão de teste.\n\n* 📝 Documentação**\n\n**Notas de instalação do ARM: ** Uma nota de solução de problemas no README esclarece que os erros de compilação `usocket`, `serialport` e `node-gyp` nos sistemas Raspberry Pi/ARM se originam de dependências seriais opcionais e podem ser ignorados.",
11
+ "nl": "* 🚀 Functies en UX-verbeteringen**\n\n**Hybrid Modbus TCP-ondersteuning: ** Introductie van hybride Modbus TCP-ondersteuning (`modbus-serie`) om vluchtige parameters (zoals doeltemperaturen, verwarmingscurven en spoelen/schakelaars) rechtstreeks naar het Luxtronik RAM-geheugen te schrijven zonder slijtage van het EEPROM/Flash-geheugen te veroorzaken, terwijl de volledige telemetrie via de oorspronkelijke poort 8889/8214 wordt doorgelezen.\n**Slimme ZIP-configuratie: ** Het tabblad Circulatiepomp (ZIP) in de beheerdersinterface volledig opnieuw ontworpen. Er is een dynamische dropdown (`zip_control_mode`) geïntroduceerd om intuïtief te schakelen tussen de interne controller, de externe actor (bijvoorbeeld Shelly) en Modbus TCP (Coil 7), waarbij irrelevante instellingen automatisch worden verborgen om verkeerde configuraties te voorkomen.\n**ZIP Countdown Timer: ** Een nieuw virtueel datapunt toegevoegd (`Information.03_Outputs.virtual_zip_remaining_time`) dat de resterende looptijd van de actieve circulatiepompcyclus in seconden weergeeft.\n**Naadloze migratie: ** Implementeerde een automatische routine voor achtergrondmigratie om bestaande gebruikersconfiguraties naadloos te upgraden naar de nieuwe ZIP-besturingslogica zonder gegevensverlies.\n\n* 🐛 Opgeloste fouten**\n\n**Gebruikersinterface voor Telegram-meldingen: ** Er is een logisch probleem opgelost in `JSONConfig.json` waarbij het Telegram-waarschuwingsbericht onjuist werd weergegeven, zelfs als er exemplaren waren geïnstalleerd en beschikbaar waren, en het kapotte pictogram op de testknop is verholpen.\n\n* 📝 Documentatie**\n\n**Aantekeningen bij de installatie van ARM: ** Een opmerking voor probleemoplossing toegevoegd aan de README waarin wordt verduidelijkt dat de compilatiefouten van `usocket`, `serialport` en `node-gyp` op Raspberry Pi-/ARM-systemen het gevolg zijn van optionele seriële afhankelijkheden en veilig kunnen worden genegeerd.",
12
+ "fr": "* 🚀 Fonctionnalités et UX améliorées**\n\n**Support Modbus TCP hybride :** Introduction du support Modbus TCP hybride (« modbus-série ») pour écrire les paramètres volatils (températures cibles, courbes de chauffage, bobines et commutateurs) directement dans la RAM Luxtronik sans endommager les EEPROM ou la mémoire flash, tout en continuant à lire la télémétrie complète via le port natif 8889/8214.\n**Configuration ZIP intelligente :** L'onglet Circulation Pump (ZIP) de l'interface d'administration a été complètement repensé. Ajout d'un menu déroulant dynamique (« zip_control_mode ») permettant de basculer intuitivement entre Controller interne, External Actor (Shelly) et Modbus TCP (Coil 7), masquant automatiquement les paramètres inutiles pour éviter les erreurs de configuration.\n**Compte à rebours ZIP :** Ajout d'un nouveau point de données virtuel (« Information.03_outputs.virtual_ZIP_Remaining_Time ») qui affiche la durée restante du cycle actif de la pompe de circulation en secondes.\n**Migration fluide :** Mise en place d'une routine de migration automatique en arrière-plan pour passer facilement à la nouvelle logique de contrôle ZIP sans perte de données.\n\n* 🐛 Bugcorrects**\n\n**Interface des notifications Telegram :** Correction d'un problème logique dans `JSONConfig.json` qui affichait mal le message d'avertissement de Telegram alors que des instances étaient installées et disponibles, et a corrigé l'icône cassée sur le bouton de test.\n\n* 📝 Documentation**\n\n**Notes d'installation d'ARM :** Ajout d'une note de dépannage au README précisant que les erreurs de compilation « usocket », « serialport » et « node-gyp» sur les systèmes Raspberry Pi/ARM sont dues à des dépendances série facultatives et peuvent être ignorées en toute sécurité.",
13
+ "it": "* 🚀 Funzioni e UX migliorate**\n\n**Supporto Modbus TCP ibrido (`modbus-serial`) per scrivere parametri volatili (ad es. temperature target, curve di riscaldamento e bobine/switch) direttamente nella RAM Luxtronik senza causare usura della memoria EEPROM/Flash, continuando a leggere la telemetria completa tramite la porta nativa 8889/8214.\n**Configurazione Smart ZIP: ** La scheda ZIP è stata completamente ridisegnata. Ha introdotto un menu a discesa dinamico (`zip_control_mode`) per passare intuitivamente da Internal Controller, External Actor (ad es. Shelly) e Modbus TCP (Bobina 7), nascondendo automaticamente le impostazioni irrilevanti per evitare errori.\n**ZIP Countdown Timer: ** Aggiunto un nuovo datapoint virtuale (`Information.03_outputs.VIRTUAL_ZIP_REMAINING_TIME`) che mostra l'autonomia residua del ciclo attivo in secondi.\n**Migrazione senza interruzioni: ** Implementata una routine automatica in background per aggiornare le configurazioni utente esistenti alla nuova logica ZIP senza perdita di dati.\n\n* 🐛 Bugfix**\n\n**Interfaccia utente di Telegram: ** Risolto un problema logico in `JsonConfig.json` in cui l'avviso di Telegram veniva visualizzato erroneamente anche se le istanze erano installate e disponibili e l'icona rotta sul pulsante di test.\n\n* 📝 Documenti**\n\n**Note di installazione ARM: ** Aggiunta una nota al README in cui si chiarisce che gli errori di compilazione uSocket, serialport e node-gyp sui sistemi Raspberry Pi/ARM derivano da dipendenze seriali opzionali e possono essere ignorati.",
14
+ "es": "* 🚀 Funciones y mejoras en UX**\n\n**Soporte Modbus TCP híbrido: ** Introdujo el soporte Modbus TCP híbrido («serie modbus») para escribir parámetros volátiles (por ejemplo, temperaturas objetivo, curvas de calentamiento y bobinas o conmutadores) directamente en la RAM Luxtronik sin desgastar la EEPROM/Flash, sin dejar de leer la telemetría completa a través del puerto nativo 8889/8214.\n**Configuración ZIP inteligente: ** Se rediseñó por completo la pestaña Bomba de circulación (ZIP) de la UI de administrador. Introdujo un menú desplegable dinámico (`zip_control_mode`) para cambiar de forma intuitiva entre el controlador interno, el actor externo (por ejemplo, Shelly) y el Modbus TCP (Coil 7), ocultando automáticamente los ajustes irrelevantes para evitar errores de configuración.\n**Contador regresivo ZIP: ** Se ha añadido un nuevo punto de datos virtual (`Information.03_Outputs.Virtual_ZIP_REMAINING_TIME`) que muestra el tiempo de funcionamiento restante del ciclo activo de la bomba de circulación en segundos.\n**Migración fluida: ** Se implementó una rutina de migración automática en segundo plano para actualizar sin problemas las configuraciones de usuario actuales a la nueva lógica de control ZIP sin perder datos.\n\n* 🐛 Correcciones**\n\n**Interfaz de notificaciones de Telegram: ** Se ha corregido un problema lógico en `JSONConfig.json por el que el mensaje de aviso de Telegram aparecía mal incluso cuando había instancias instaladas y disponibles, y se ha corregido el icono roto del botón de prueba.\n\n* 📝 Documentación**\n\n**Notas de instalación de ARM: ** Se ha añadido una nota de solución de problemas al README en la que se aclara que los errores de compilación de «usocket», «puerto serie» y «node-gyp» en los sistemas Raspberry Pi/ARM se deben a dependencias en serie opcionales y se pueden ignorar de forma segura.",
15
+ "pl": "* 🚀 Funkcje i ulepszenia UX**\n\n**Hybrid Modbus TCP Support: ** Wprowadzono hybrydową obsługę Modbus TCP („modbus serial”) do zapisywania parametrów zmiennych (np. docelowych temperatur, krzywych nagrzewania i cewki/przełączników) bezpośrednio do pamięci RAM Luxtronik bez powodowania zużycia pamięci EEPROM/flash, przy jednoczesnym kontynuowaniu odczytu pełnej telemetrii przez natywny port 8889/8214.\n**Inteligentna konfiguracja ZIP: ** Całkowicie przeprojektowana karta Pompa cyrkulacyjna (ZIP) w interfejsie administratora. Wprowadzono dynamiczne rozwijane menu („zip_control_mode”) do intuicyjnego przełączania między kontrolerem wewnętrznym, zewnętrznym aktorem (np. Shelly) i Modbus TCP (Coil 7), automatycznie ukrywając nieistotne ustawienia, aby zapobiec błędnym konfiguracjom.\n**ZIP Countdown Timer: ** Dodano nowy wirtualny punkt danych (`Information.03_Outputs.Virtual_ZIP_Remaining_Time`), który wyświetla pozostały czas działania aktywnego cyklu pompy obiegowej w sekundach.\n**Bezproblemowa migracja: ** Zaimplementowano automatyczną procedurę migracji w tle, aby bezproblemowo aktualizować istniejące konfiguracje użytkowników do nowej logiki sterowania ZIP bez utraty danych.\n\n* 🐛 Poprawki błędów**\n\n**Interfejs powiadomień telegramu: ** Naprawiono problem logiczny w `JSONConfig.json`, w którym komunikat ostrzegawczy Telegram był nieprawidłowo wyświetlany nawet wtedy, gdy instancje były zainstalowane i dostępne, i naprawiono uszkodzoną ikonę na przycisku testowym.\n\n* 📝 Dokumentacja**\n\n**Uwagi dotyczące instalacji ARM: ** Dodano do README informację dotyczącą rozwiązywania problemów wyjaśniającą, że błędy kompilacji „usocket”, „serialport” i „node-gyp\"w systemach Raspberry Pi/ARM pochodzą z opcjonalnych zależności szeregowych i można je bezpiecznie zignorować.",
16
+ "uk": "* 🚀 Функції та вдосконалення UX**\n\n**Підтримка гібридного Modbus TCP: ** Введена гібридна підтримка Modbus TCP (`modbus-serial`) для запису мінливих параметрів (наприклад, цільових температур, кривих нагрівання та котушки/комутатори) безпосередньо в оперативну пам'ять Luxtronik без зносу EEPROM/флеш-пам'яті, продовжуючи читати повну телеметрію через рідний порт 8889/8214.\n**Конфігурація Smart ZIP: ** Повністю перероблена вкладка Циркуляційний насос (ZIP) в інтерфейсі адміністратора. Введено динамічний випадаючий список (`zip_control_mode`) для інтуїтивного перемикання між внутрішнім контролером, зовнішнім актором (наприклад, Shelly) та Modbus TCP (Coil 7), автоматично приховуючи невідповідні налаштування, щоб запобігти неправильним конфігураціям.\n**Таймер зворотного відліку ZIP: ** Додано новий віртуальний пункт даних (`information.03_outputs.virtual_zip_ing_time`), який відображає решту часу роботи циклу активного циркуляційного насоса в секундах.\n**Безшовна міграція: ** Реалізовано автоматичну процедуру фонової міграції для безперешкодного оновлення існуючих конфігурацій користувачів до нової логіки керування ZIP без втрати даних.\n\n* 🐛 Виправлення вадь**\n\n**Інтерфейс сповіщень Telegram: ** Виправлено логічну проблему в `JsonConfig.json`, коли попереджувальне повідомлення Telegram неправильно відображалося, навіть коли екземпляри були встановлені та доступні, та виправлено зламану піктограму на тестовій кнопці.\n\n* 📝 Документація**\n\n**Примітки щодо встановлення ARM: ** Додано примітку щодо усунення несправностей до README, яка пояснює, що помилки компіляції `usocket`, `serialport` та `node-gyp` у системах Raspberry Pi/ARM походять від необов'язкових послідовних залежностей і можуть бути безпечно ігноровані.",
17
+ "zh-cn": "* 🚀 功能和用户体验改进**\n\n**混合 Modbus TCP 支持:** 引入了混合 Modbus TCP 支持(“modbus-serial”),可在不导致 EEPROM/闪存磨损的情况下将易失性参数(例如目标温度、加热曲线和线圈/开关)直接写入立讯内存,同时继续通过原生端口 8889/8214 读取完整的遥测数据。\n**智能 ZIP 配置:** 完全重新设计了管理员用户界面中的 “循环泵 (ZIP)” 选项卡。引入了动态下拉菜单(`zip_control_mode`),可以直观地在内部控制器、外部控制器(例如Shelly)和Modbus TCP(线圈7)之间切换,自动隐藏无关的设置以防止错误配置。\n**ZIP 倒计时器:** 添加了一个新的虚拟数据点(`Information.03_outputs.Virtual_ZIP_remaining_Time`),该数据点以秒为单位显示活跃循环泵周期的剩余运行时间。\n**无缝迁移:**实现了自动后台迁移例程,将现有用户配置无缝升级到新的ZIP控制逻辑,而不会丢失数据。\n\n* 🐛 错误修复**\n\n**电报通知用户界面:** 修复了 `jsonConfig.json` 中的一个逻辑问题,即即使实例已安装且可用,电报警告消息也无法正确显示,并修复了测试按钮上损坏的图标。\n\n* 📝 文档**\n\n**ARM 安装说明:** 在自述文件中添加了故障排除说明,澄清了树莓派/ARM 系统上的 “usocket”、“serialport” 和 “node-gy” 编译错误源于可选的串行依赖关系,可以放心地忽略。"
18
+ },
19
+ "0.18.2": {
20
+ "en": "*🔧 Maintenance & Repository Compliance**\n\n**Core Dependency Update:** Raised minimum required `js-controller` dependency to `>=7.0.7` in `io-package.json` to ensure compatibility with modern ioBroker environments (resolves E1057).\n**Full i18n Localization for Admin UI:** Added complete multi-language label sets (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) for COP power and thermal source selection dropdowns in `jsonConfig.json` (resolves W5611).\n**Package News Cleanup:** Removed unreleased intermediate tags (`0.17.0`, `0.16.1`) from `common.news` in `io-package.json` to align strictly with published NPM releases (resolves W2004).\n**CI/CD Security Compliance:** Updated GitHub auto-merge workflows for Dependabot to adhere to GitHub's updated `pull_request_target` execution policies (PR #90 / Issue #89).\n**Code Modernization:** Migrated built-in Node.js module imports to use the explicit `node:` protocol prefix (e.g. `node:fs`, `node:path`).",
21
+ "de": "* 🔧 Wartung und Repository-Konformität**\n\n**Update zur Kernabhängigkeit: ** Die Mindestabhängigkeit von `js-controller`` in `io-package.json` wurde auf `>=7.0.7` erhöht, um mit modernen ioBroker-Umgebungen kompatibel zu sein (löst E1057).\n**Vollständige i18n-Lokalisierung für Admin-UI: ** Vollständige mehrsprachige Labelsets (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) in `JSONConfig.json` hinzugefügt (löst W5611).\n**Package News Cleanup: ** Unveröffentlichte Zwischen-Tags (`0.17.0`, `0.16.1`) von `common.news` in `io-package.json` entfernt, um sie genau an NPM-Releases anzupassen (löst W2004).\n**CI/CD-Sicherheit: ** GitHub-Auto-Merge-Workflows für Dependabot wurden an GitHubs neue `pull_request_target`-Regeln angepasst (PR #90/Issue #89).\n**Code-Modernisierung: ** Integrierte Node.js Modulimporte auf das explizite `node: `-Protokollpräfix migriert (z. B. `node:fs`, `node:path`).",
22
+ "ru": "* 🔧 Техническое обслуживание и соответствие требованиям репозитория**\n\n**Обновление основных зависимостей: ** Минимальная требуемая зависимость `js-controller` увеличена до `>=7.0.7` в `io-package.json` для обеспечения совместимости с современными средами IOBroker (исправлено E1057).\n**Полная локализация i18n для пользовательского интерфейса администратора: ** Добавлены полные многоязычные наборы меток (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) для выпадающих списков выбора питания и источника тепла COP в `JsonConfig.json` (разрешение W5611).\n**Очистка новостей о пакетах: ** Удалены неопубликованные промежуточные теги (`0.17.0`, `0.16.1») из `common.news` в `io-package.json`, чтобы строго соответствовать опубликованным выпускам NPM (резолюция W2004).\n**Соответствие требованиям безопасности CI/CD: ** Обновлены рабочие процессы автоматического объединения GitHub для Dependabot в соответствии с обновленными политиками выполнения GitHub `pull_request_target` (PR #90/Issue #89).\n**Модернизация кода: ** Перемещен импорт встроенного модуля Node.js для использования явного префикса протокола `node:` (например, `node:fs`, `node:path`).",
23
+ "pt": "* 🔧 Manutenção e conformidade do repositório**\n\n**Atualização de dependência básica: ** Aumentou a dependência mínima de `js-controller` para `>=7.0.7` em `io-package.json` para garantir compatibilidade com ambientes IOBroker modernos (resolve E1057).\n**Localização i18n completa para Admin UI: ** Foram adicionados rótulos completos em vários idiomas (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) para seleção de fonte térmica e de energia COP em `JSONConfig.json` (resolve W5611).\n**Limpeza de notícias do pacote: ** Removemos tags intermediárias inéditas (`0.17.0`, `0.16.1`) de `common.news` em `io-package.json` para alinhar com versões publicadas do NPM (resolve W2004).\n**Conformidade de segurança CI/CD: ** Fluxos de trabalho de mesclagem automática do GitHub para Dependabot aderir às políticas de execução `pull_request_target` do GitHub (PR #90/Issue #89).\n**Modernização de código: ** Importações do módulo Node.js embutido migrado para usar o prefixo explícito `node: `(ex: `node:fs`, `node:path`).",
24
+ "nl": "* 🔧 Onderhoud en naleving van de opslagplaats**\n\n**Core-afhankelijkheidsupdate: ** Verhoogd de minimaal vereiste `js-controller` afhankelijkheid naar `>=7.0.7` in `io-package.json` om compatibiliteit met moderne IOBroker-omgevingen te garanderen (lost E1057 op).\n**Volledige i18n-lokalisatie voor Admin UI: ** Complete meertalige labelsets toegevoegd (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) voor keuzelijsten voor COP-voeding en thermische bronselectie in `JSONConfig.json` (lost W5611 op).\n**Package News Cleanup: ** Niet eerder uitgebrachte tussentijdse tags (`0.17.0`, `0.16.1`) verwijderd uit `common.news` in `io-package.json` om ze strikt aan te passen aan gepubliceerde NPM-releases (lost W2004 op).\n**Conformiteit met CI/CD-beveiliging: ** Bijgewerkte GitHub-workflows voor automatische samenvoeging zodat Dependabot kan voldoen aan het bijgewerkte uitvoeringsbeleid van `pull_request_target` van GitHub (PR #90 /Issue #89).\n**Modernisering van de code: ** De ingebouwde module Node.js wordt geïmporteerd om het expliciete protocolvoorvoegsel „node:” te gebruiken (bijv. `node:fs`, `node:path`).",
25
+ "fr": "* 🔧 Maintenance et conformité du dépôt**\n\n**Core Dependency Update :** Augmentation de la dépendance minimale requise à « js-controller » à « >=7.0.7 » dans « io-package.json » afin de garantir la compatibilité avec les environnements IObroker modernes (résolution E1057).\n**Localisation complète d'i18n pour l'interface d'administration :** Ajout de jeux d'étiquettes multilingues complets (« ru », « pt », « nl », « fr », « it », « es », « pl », « uk », « zh-cn ») pour les listes déroulantes de sélection de l'alimentation COP et des sources thermiques dans « JSONConfig.json » (résout W5611).\n**Package News Cleanup :** Suppression des tags intermédiaires inédits (« 0.17.0 », « 0.16.1 ») de « common.news » dans « io-package.json » pour s'aligner strictement sur les versions publiées de NPM (résout W2004).\n**Conformité à la sécurité CI/CD :** Mise à jour des flux de fusion automatique de GitHub pour que Dependabot respecte les règles d'exécution « pull_request_target » de GitHub (PR #90/Issue #89).\n**Modernisation du code :** Le module Node.js intégré a migré pour utiliser le préfixe explicite du protocole node : (par exemple node:fs, node:path).",
26
+ "it": "* 🔧 Manutenzione e conformità del deposito**\n\n**Core Dependency Update: ** Aumentata la dipendenza minima `js-controller` a `>=7.0.7` in `io-package.json` per garantire la compatibilità con i moderni ambienti IOBroker (risolve E1057).\n**Localizzazione i18n completa per l'interfaccia utente di amministrazione: ** Aggiunti set completi di etichette multilingue (ru`, `pt`, `nl`, fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) per i menu COP power e thermal source in `JSONConfig.json` (risolve W5611).\n**Package News Cleanup: ** Rimossi i tag intermedi inediti (`0.17.0`, `0.16.1`) da `common.news` in `io-package.json` per allinearli alle versioni NPM pubblicate (risolve W2004).\n**Conformità alla sicurezza CI/CD: ** Flussi di lavoro di fusione automatica di GitHub aggiornati per aderire alle policy di esecuzione `pull_request_target` di GitHub (PR #90/Issue #89).\n**Modernizzazione del codice: ** Il modulo Node.js integrato migrato utilizza il prefisso esplicito `node: `(es. `node:fs`, `node:path`).",
27
+ "es": "* 🔧 Mantenimiento y cumplimiento del repositorio**\n\n**Actualización de dependencia básica: ** Se elevó la dependencia mínima requerida de «js-controller» a >=7.0.7 en «io-package.json» para garantizar la compatibilidad con los entornos modernos de IOBroker (resuelve el E1057).\n**Localización completa del i18n para la interfaz de usuario de administrador: ** Se han añadido conjuntos completos de etiquetas multilingües (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) para los menús desplegables de potencia y fuentes térmicas de COP en `JsonConfig.json` (resuelve el W5611).\n**Package News Cleanup: ** Se han eliminado las etiquetas intermedias inéditas (0.17.0, 0.16.1) de common.news en io-package.json para alinearlas estrictamente con las versiones publicadas de NPM (resuelve W2004).\n**Cumplimiento de seguridad de CI/CD: ** Se han actualizado los flujos de trabajo de fusión automática de GitHub para que el Dependabot cumpla con las políticas de ejecución de «pull_request_target» de GitHub (PR #90/Issue #89).\n**Modernización del código: ** Se migraron las importaciones del módulo Node.js integrado para usar el prefijo de protocolo `node: `explícito (p. ej., `node:fs`, `node:path).",
28
+ "pl": "* 🔧 Zgodność z konserwacją i repozytorium**\n\n**Aktualizacja podstawowej zależności: ** Podniesiono minimalną wymaganą zależność `js-controller` do `>=7.0.7` w `io-package.json` w celu zapewnienia zgodności z nowoczesnymi środowiskami ioBroker (rozwiązuje E1057).\n**Pełna lokalizacja i18n dla interfejsu administratora: ** Dodano kompletne wielojęzyczne zestawy etykiet (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) dla menu rozwijanego wyboru zasilania COP i źródła termicznego w `JSONConfig.json` (rozwiązuje W5611).\n**Czyszczenie wiadomości pakietu: ** Usunięto niepublikowane znaczniki pośrednie (`0.17.0`, `0.16.1`) z `common.news` w `io-package.json` w celu ścisłego dopasowania do opublikowanych wersji NPM (rozwiązuje W2004).\n**Zgodność z zabezpieczeniami CI/CD: ** Zaktualizowano przepływy pracy automatycznego scalania GitHub dla Dependabot, aby były zgodne ze zaktualizowanymi zasadami wykonania `pull_request_target` GitHub (PR #90/Issue #89).\n**Modernizacja kodu: ** Migrowany wbudowany import modułu Node.js w celu użycia jawnego prefiksu protokołu `node: `(np. `node:fs`, `node:path`).",
29
+ "uk": "* 🔧 Технічне обслуговування та відповідність сховища**\n\n**Оновлення залежності ядра: ** Підвищено мінімальну необхідну залежність `js-controller` до `>=7.0.7` у `io-package.json` для забезпечення сумісності з сучасними середовищами IObroker (вирішує E1057).\n**Повна локалізація i18n для інтерфейсу адміністратора: ** Додано повні багатомовні набори міток (`ru`, `pt`, `nl`, `fr`, `it`, `es`, `pl`, `uk`, `zh-cn`) для випадаючих списків вибору живлення COP та теплового джерела в `JsonConfig.json` (вирішує W5611).\n**Очищення новин пакета: ** Видалено невипущені проміжні теги (`0.17.0`, `0.16.1`) з `common.news` у `io-package.json` для суворого узгодження з опублікованими випусками NPM (вирішує W2004).\n**Відповідність безпеки CI/CD: ** Оновлені робочі процеси автоматичного об'єднання GitHub для Dependabot, щоб дотримуватися оновленої політики виконання GitHub `pull_request_target` (PR #90/Випуск #89).\n**Модернізація коду: ** Перенесено імпорт вбудованого модуля Node.js для використання явного префікса протоколу `node: `(наприклад, `node:fs`, `node:path`).",
30
+ "zh-cn": "* 🔧 维护和存储库合规性**\n\n**核心依赖关系更新:** 在 io-package.json 中将 “js-controller” 所需的最低依赖关系提高到 `>=7.0.7`,以确保与现代 IOBroker 环境兼容(已解决 E1057)。\n**管理员用户界面的完整 i18n 本地化:** 在 `jsonConfig.json` 中为 COP 电源和热源选择下拉菜单添加了完整的多语言标签集(`ru`、`pt`、`nl`、`fr`、`it`、`es`、`pl`、`uk`、`zh-cn`)(已解决 W5611)。\n**Package News Cleanup:** 从 `io-package.json` 的 `common.news` 中删除了未发布的中间标签(`0.17.0`,`0.16.1`),以严格与已发布的 NPM 版本保持一致(已解决 W2004)。\n**CI/CD 安全合规性:** 更新了 Dependabot 的 GitHub 自动合并工作流程,以遵守 GitHub 更新后的 `pull_request_target` 执行政策(PR #90/问题 #89)。\n**代码现代化:** 迁移了内置 Node.js 模块导入,以使用明确的 `node: `协议前缀(例如 `node: fs`、`node: path`)。"
31
+ },
6
32
  "0.18.1": {
7
33
  "en": "*🐛 Bugfixes**\n\n**COP Database Persistence:** Fixed a critical bug in the object manager's cleanup routine (`cleanupStates`). The internal database folder (`hidden.cop_buckets`) was missing from the exclusion list and got aggressively deleted upon every adapter restart, resulting in wiped COP histories and `(null)` values. The hidden states are now strictly protected against the cleanup process, ensuring long-term persistence for energy calculations.",
8
34
  "de": "* 🐛 Bugfixes**\n\n**COP Database Persistence: ** Kritischer Bug im Objektmanager behoben (`CleanupStates`). Der interne Datenbankordner (`hidden.cop_buckets`) fehlte in der Ausschlussliste und wurde bei jedem Adapter-Neustart gelöscht, wodurch COP-Historien und `(Null)` Werte gelöscht wurden. Die versteckten Staaten sind jetzt strikt vor der Säuberung geschützt, was Energieberechnungen langfristig ermöglicht.",
@@ -67,32 +93,6 @@
67
93
  "pl": "#### 🛠 Poprawki błędów i ulepszenia\n\n- **akość kodu i CI/CD:** Naprawiono awarie rurociągu eSlint `no-prototype-builtins` w `ObjectManager.ts` zastępując bezpośrednie wywołania `.hasOwnProperty () `bezpiecznymi metodami `Object.prototype.hasOwnProperty.call ()`. ",
68
94
  "uk": "#### 🛠 Виправлення помилок та вдосконалення\n\n- **кість коду та CI/CD:** Виправлено помилки конвеєра ESLint `no-prototype-builtins` у `ObjectManager.ts` шляхом заміни прямих викликів `.hasOwnProperty () `безпечними методами `Object.prototype.hasOwnProperty.call ()`. ",
69
95
  "zh-cn": "#### 🛠 错误修复和增强\n\n-**代码质量和 CI/CD:** 通过使用安全的 `Object.prototype.hasownProperty.call () `方法替换直接调用 `ObjectManager.ts` 中的 ESLint `no-prototype.builtins` 管道故障。"
70
- },
71
- "0.17.0": {
72
- "en": "#### 🚀 Features\n\n- **COP & Efficiency Calculator:** Introduced a comprehensive COP (Coefficient of Performance) calculation engine to track heat pump efficiency.\n- **External Smart Meter Support:** Users can now choose to use internal Luxtronik estimates or link high-precision external sensors (e.g., Shelly 3EM or M-Bus heat meters) via ioBroker Object IDs for power consumption and thermal energy generation.\n- **Granular Live Metrics:** The adapter now dynamically analyzes the active operating state to split and calculate live daily COP values for \"Total\", \"Heating\", and \"Hot Water\" independently.\n- **Persistent Time Rollovers:** Implemented a robust \"snapshot\" system with absolute virtual counters. The adapter automatically detects day, month, and year rollovers to persist data and guarantee accurate long-term calculations, even across adapter restarts or ioBroker reboots.\n- **Dedicated Efficiency UI:** Added a new \"Efficiency / COP\" configuration tab to easily manage energy data sources and toggle the calculation engine.\n- **Connection & Polling Status:** Added a new system datapoint `info.lastUpdate`. This state continuously tracks the exact timestamp of the last successful data retrieval, making it easy to monitor the adapter's health and polling activity in visualisations like VIS or Lovelace.\n\n#### 🛠 Bugfixes & Enhancements\n\n- **Object Tree Creation:** Fixed an issue where hidden data buckets for the COP calculation were not created because parent directories were missing.\n- **Timestamp Formatting:** Resolved a strict type mismatch error in the ioBroker log by correctly formatting `info.lastUpdate` as an ISO string instead of a numeric timestamp.\n- **State Properties & Code Quality:** Resolved strict TypeScript and ESLint warnings (missing JSDoc annotations, missing read/write object definitions) in the new COP manager.\n- **Modernized ioBroker API:** Replaced deprecated `setStateAsync` method calls with the modern, promise-based `setState` standard across the COP calculation engine.\n- **Config UI Sorting:** Ensured the newly generated configuration tabs maintain a logical and consistent order across rebuilds.\n- **Internal Mapping:** Restructured the `info` folder mapping to cleanly accommodate adapter-level metadata alongside hardware telemetry.",
73
- "de": "#### 🚀 Merkmale\n\n- **OP- und Effizienzrechner:** Es wurde ein umfassendes Modul zur Berechnung des Wirkungsgrads von Wärmepumpen eingeführt. \n- **upport für externe Smart Meter:** Benutzer können nun interne Luxtronik-Schätzungen verwenden oder hochpräzise externe Sensoren (z. B. Shelly 3EM oder M-Bus) über ioBroker Object IDs für Stromverbrauch und Wärmeerzeugung verbinden. \n- **ranular Live Metrics:** Der Adapter analysiert nun dynamisch den Betriebszustand und berechnet die täglichen Live-COP-Werte für „Total“, „Heating“ und „Hot Water“ unabhängig. \n- **ersistent Time Rollovers:** Ein robustes Snapshot-System mit absoluten virtuellen Zählern. Der Adapter erkennt automatisch Tag, Monat und Jahr, um Daten beizubehalten und auch bei Adapterneustarts oder ioBroker-Neustarts genaue Berechnungen zu garantieren. \n- **igene Effizienz-UI:** Neuer Tab „Effizienz/COP“ hinzugefügt, um Energiedatenquellen zu verwalten und die Rechenmaschine umzuschalten. \n- **erbindungs- und Abfragestatus:** Neues Systemdatum `Info.LastUpdate` hinzugefügt. Dieser Status verfolgt ständig den exakten Zeitstempel des letzten Datenabrufs, sodass der Zustand des Adapters in Visualisierungen wie VIS oder Lovelace leicht überwacht werden kann. \n\n#### 🛠 Bugfixes & Verbesserungen\n\n- **bjektbaum erstellen:** Es wurde ein Fehler behoben, bei dem keine übergeordneten Ordner für die COP-Berechnung erstellt wurden. \n- **imestamp-Format:** Es wurde ein strikter Typfehler im ioBroker-Log behoben, indem `Info.LastUpdate` korrekt als ISO-String statt numerisch formatiert wurde. \n- **tate Properties & Code Quality:** Strikte TypeScript- und ESLint-Warnungen (fehlende JSDoc-Annotationen, Lese-/Schreib-Objektdefinitionen) im neuen COP-Manager behoben. \n- **odernisierte IOBroker-API:** Die veralteten `setStateAsync`-Methodenaufrufe wurden in der COP-Rechenmaschine durch `setState`-Standard ersetzt. \n- **ortierung der Konfigurationsoberfläche:** Sortiert die neu generierten Konfigurations-Tabs bei allen Rebuilds. \n- **nternes Mapping:** Die Ordnerzuweisung `info` wurde neu strukturiert, um Adaptermetrie und Hardware-Telemetrie abzudecken. ",
74
- "ru": "#### 🚀 Функции\n\n- **алькулятор КПД и эффективности:** Представлен комплексный механизм расчета коэффициента полезного действия (COP) для отслеживания эффективности теплового насоса. \n- **оддержка внешних интеллектуальных счетчиков:** Теперь пользователи могут использовать внутренние оценки Luxtronik или подключать высокоточные внешние датчики (например, теплосчетчики Shelly 3EM или M-Bus) к идентификаторам объектов IOBroker для энергопотребления и выработки тепловой энергии. \n- **етализированные метрики в реальном времени:** Адаптер теперь динамически анализирует активное рабочее состояние для независимого разделения и вычисления ежедневных значений COP в реальном времени для «всего», «отопления» и «горячей воды». \n- **остоянные переносы времени:** Внедрена надежная система «снимков» с абсолютными виртуальными счетчиками. Адаптер автоматически определяет перенос даты, месяца и года, что позволяет сохранять данные и обеспечивать точность расчетов в долгосрочной перспективе даже при перезагрузке адаптера или перезагрузке IOBroker. \n- **пециальный пользовательский интерфейс по эффективности:** Добавлена новая вкладка конфигурации «Эффективность/COP», позволяющая легко управлять источниками данных об энергопотреблении и переключать механизм вычислений. \n- **остояние подключения и опроса:** Добавлена новая системная точка данных `Info.LastUpdate`. Это состояние непрерывно отслеживает точное время последнего успешного извлечения данных, что позволяет легко отслеживать состояние адаптера и активность опросов в таких визуализациях, как VIS или Lovelace. \n\n#### 🛠 Исправления ошибок и улучшения\n\n- **оздание дерева объектов:** Исправлена ошибка, из-за которой скрытые сегменты данных для расчета COP не создавались из-за отсутствия родительских каталогов. \n- **орматирование отметок времени:** Исправлена ошибка строгого несоответствия типов в журнале IOBroker, правильно отформатировав `Info.lastUpdate` как строку ISO вместо числовой метки времени. \n- **войства состояния и качество кода:** Исправлены строгие предупреждения TypeScript и ESLint (отсутствие аннотаций JSDoc, отсутствие определений объектов для чтения/записи) в новом диспетчере COP. \n- **одернизированный API IOBroker:** В вычислительном движке COP устаревшие вызовы методов `setStateAsync` заменены современным стандартом setState, основанным на обещаниях. \n- **ортировка пользовательского интерфейса конфигурации:** Обеспечивает сохранение логического и согласованного порядка вновь созданных вкладок конфигурации при повторных сборках. \n- **нутреннее сопоставление:** Изменена структура сопоставления папок «info» для точного размещения метаданных на уровне адаптера и аппаратной телеметрии. ",
75
- "pt": "#### 🚀 Recursos\n\n- **alculadora de COP e eficiência:** Introduziu um mecanismo abrangente de cálculo de COP para rastrear a eficiência da bomba de calor. \n- **uporte externo de Smart Meter:** Agora, os usuários podem usar estimativas internas da Luxtronik ou conectar sensores externos de alta precisão (ex., Shelly 3EM ou M-Bus) via IOBroker Object IDs para consumo e geração de energia térmica. \n- **étricas granulares ao vivo:** O adaptador agora analisa dinamicamente o estado ativo para dividir e calcular os valores COP diários para “Total”, “Aquecimento” e “Água Quente”. \n- **ersistent Time Rollovers:** Implementou um robusto sistema de “snapshot” com contadores virtuais. O adaptador detecta automaticamente as mudanças de dia, mês e ano para manter os dados e garantir cálculos precisos a longo prazo, mesmo em reinicializações ou IOBroker. \n- **I de eficiência dedicada:** Foi adicionada a nova guia “Eficiência/COP” para gerenciar fontes de dados de energia e ativar o motor de cálculo. \n- **tatus de conexão e pesquisa:** Novo datapoint `info.lastUpdate`. Esse estado rastreia continuamente a data exata da última recuperação bem-sucedida, facilitando o monitoramento da saúde e da pesquisa do adaptador em visualizações como VIS ou Lovelace. \n\n#### 🛠 Correções e melhorias\n\n- **riação da Árvore de Objetos:** Foi corrigido um problema em que os blocos de dados ocultos para o cálculo da COP não eram criados por falta de diretórios. \n- **ormatação de data e hora:** Resolveu um erro estrito de incompatibilidade de tipos no log do IOBroker ao formatar `info.lastUpdate` como string ISO em vez de numérico. \n- **tate Properties & Code Quality:** Resolveu avisos estritos de TypeScript e ESLint (anotações JSDoc e definições de objetos de leitura/gravação) no novo gerenciador COP. \n- **PI IOBroker modernizada:** Substituiu as chamadas obsoletas do método `setStateAsync` pelo moderno padrão `setState` baseado em promessas no mecanismo de cálculo do COP. \n- **onfig UI Sorting:** Garante uma ordem lógica e consistente nas novas abas de configuração. \n- **apeamento interno:** Reestruturou a pasta `info` para acomodar metadados de adaptador e telemetria de hardware. ",
76
- "nl": "#### 🚀 Kenmerken\n\n- **OP- en efficiëntiecalculator:** Introduceerde een uitgebreide COP-berekeningsengine (Coëfficiënt van Prestatie) om het rendement van de warmtepomp bij te houden. \n- **xterne ondersteuning voor slimme meters:** Gebruikers kunnen er nu voor kiezen om interne Luxtronik-schattingen te gebruiken of om uiterst nauwkeurige externe sensoren (zoals Shelly 3EM- of M-Bus-warmtemeters) te koppelen via IOBroker Object ID's voor het energieverbruik en de opwekking van thermische energie. \n- **edetailleerde live statistieken:** De adapter analyseert nu dynamisch de actieve bedrijfstoestand om de actuele dagelijkse COP-waarden voor „Totaal”, „Verwarming” en „Warm water” onafhankelijk van elkaar te splitsen en te berekenen. \n- **ersistent Time Rollovers:** Implementeerde een robuust „snapshotsysteem” met absolute virtuele tellers. De adapter detecteert automatisch rollovers van dagen, maanden en jaren om gegevens bij te houden en nauwkeurige berekeningen op lange termijn te garanderen, zelfs wanneer de adapter opnieuw wordt opgestart of ioBroker opnieuw wordt opgestart. \n- **peciale gebruikersinterface voor efficiëntie:** Een nieuw configuratietabblad „Efficiëntie/COP” toegevoegd om eenvoudig energiegegevensbronnen te beheren en de rekenmachine in te schakelen. \n- **tatus van verbinding en peiling:** Een nieuw systeemdatapunt `Info.LastUpdate` toegevoegd. Deze status houdt continu het exacte tijdstip bij van de laatste succesvolle gegevensopname, waardoor het eenvoudig is om de status van de adapter en de polling-activiteit te controleren in visualisaties zoals VIS of Lovelace. \n\n#### 🛠 Oplossingen en verbeteringen\n\n- **bjectstructuur aanmaken:** Probleem opgelost waarbij verborgen gegevensemmers voor de COP-berekening niet werden aangemaakt omdat de bovenliggende mappen ontbraken. \n- **ijdstempelopmaak:** Er is een fout opgelost die strikt niet overeenkwam met het type in het IOBroker-logboek door `Info.LastUpdate` correct te formatteren als een ISO-tekenreeks in plaats van een numeriek tijdstempel. \n- **tatuseigenschappen en codekwaliteit:** Strikte TypeScript- en ESLint-waarschuwingen (ontbrekende JSDoc-annotaties, ontbrekende definities van lees-/schrijfobjecten) opgelost in de nieuwe COP-manager. \n- **emoderniseerde IOBroker API:** Vervangen van verouderde aanroepen van de `SetStateAsync` methode door de moderne, op beloften gebaseerde `setState` standaard in de COP-berekeningsengine. \n- **ortering van de gebruikersinterface van de configuratie:** Zorgde ervoor dat de nieuw gegenereerde configuratietabbladen een logische en consistente volgorde behouden bij alle herbouwingen. \n- **nterne toewijzing:** De maptoewijzing van de `info` is geherstructureerd om naast hardwaretelemetrie ook metagegevens op adapterniveau overzichtelijk onder te brengen. ",
77
- "fr": "#### 🚀 Fonctions\n\n- **Calculateur de COP et d'efficacité :** A introduit un moteur de calcul complet du COP (coefficient de performance) pour suivre l'efficacité des pompes à chaleur.\n- **Prise en charge des compteurs intelligents externes :** Les utilisateurs peuvent désormais utiliser des estimations internes de Luxtronik ou relier des capteurs externes de haute précision (par exemple, des compteurs de chaleur Shelly 3EM ou M-Bus) via IObroker Object ID.\n- **Granular Live Metrics :** L'adaptateur analyse désormais l'état de fonctionnement actif de manière dynamique et calcule les COP quotidiens en temps réel pour « Total », « Chauffage » et « Eau chaude ».\n- **Permanent Time Rollovers :** Mise en place d'un solide système de « snapshots » avec compteurs virtuels absolus. L'adaptateur détecte automatiquement les reports de jour, de mois et d'année pour conserver les données et garantir des calculs précis à long terme, même en cas de redémarrage ou d'IObroker.\n- **Interface utilisateur dédiée :** Ajout d'un nouvel onglet « Efficience/COP » pour gérer facilement les sources de données énergétiques et activer le moteur de calcul.\n- **État de la connexion et du sondage :** Ajout du point de données « Info.LastUpdate ». Cet état suit en continu l'horodatage exact de la dernière récupération de données, ce qui permet de suivre facilement l'état de l'adaptateur et les sondages dans des visualisations comme VIS ou Lovelace.\n\n#### 🛠 Corrections et améliorations\n\n- **Création d'une arborescence d'objets :** Correction d'un bug qui empêchait de créer des compartiments de données cachés pour le calcul du COP.\n- **Formatage de l'horodatage :** Correction d'une erreur de type dans le journal IOBroker en formatant correctement « Info.LastUpdate » en chaîne ISO au lieu d'un horodatage numérique.\n- **Propriétés de l'état et qualité du code :** Résolution des avertissements TypeScript et ESLint (annotations JSDoc manquantes, définitions d'objets en lecture/écriture) dans le nouveau gestionnaire COP.\n- **API IOBroker modernisée :** Les appels à la méthode obsolète « SetStateAsync » ont été remplacés par la norme moderne basée sur les promesses du moteur de calcul COP.\n- **Tri de l'interface utilisateur :** Les nouveaux onglets de configuration conservent un ordre logique et cohérent lors des rebuilds.\n- **Cartographie interne :** Restructuration du dossier « info » pour y intégrer les métadonnées de l'adaptateur et la télémétrie matérielle.",
78
- "it": "#### 🚀 Funzioni\n\n- **OP & Efficiency Calculator:** Introdotto un motore completo di calcolo del COP per monitorare l'efficienza della pompa di calore. \n- **upporto Smart Meter esterno:** Gli utenti possono ora scegliere di utilizzare stime interne Luxtronik o collegare sensori esterni ad alta precisione (ad esempio, contatori di calore Shelly 3EM o M-Bus) tramite IOBroker Object ID. \n- **etriche live granulari:** L'adattatore ora analizza dinamicamente lo stato operativo attivo per dividere e calcolare i COP giornalieri per «Totale», «Riscaldamento» e «Acqua calda». \n- **ersistent Time Rollover:** Implementato un robusto sistema «snapshot» con contatori virtuali. L'adattatore rileva automaticamente i rollover di giorno, mese e anno per mantenere i dati e garantire calcoli accurati a lungo termine, anche dopo riavvii o IOBroker. \n- **nterfaccia utente dedicata:** Aggiunta una nuova scheda «Efficienza/COP» per gestire facilmente le fonti di dati energetici e attivare il motore di calcolo. \n- **tato connessione e polling:** Aggiunto un nuovo datapoint `Info.lastUpdate`. Questo stato traccia sempre l'ora esatta dell'ultimo recupero dei dati, facilitando il monitoraggio dello stato e dei sondaggi dell'adattatore in visualizzazioni come VIS o Lovelace. \n\n#### 🛠 Bug fix e migliorie\n\n- **reazione albero oggetti:** Risolto un problema che impediva la creazione di bucket di dati nascosti per il calcolo del COP \n- **ormattazione timestamp:** Risolto un errore di mancata corrispondenza di tipo nel log di IOBroker formattando `info.lastUpdate` come stringa ISO anziché numerica. \n- **roprietà di stato e qualità del codice:** Risolti i rigidi avvisi TypeScript ed ESLint (annotazioni JSDoc mancanti, definizioni di oggetti in lettura/scrittura) nel nuovo COP manager. \n- **PI IOBroker modernizzata:** Ha sostituito le chiamate al metodo `setStateAsync` obsolete con il moderno standard `setState` basato su promesse nel motore di calcolo COP. \n- **rdinamento dell'interfaccia utente:** Le nuove schede di configurazione hanno un ordine logico e coerente tra le ricostruzioni. \n- **appatura interna:** Ha ristrutturato la cartella `info` per includere i metadati a livello di adattatore e la telemetria hardware. ",
79
- "es": "#### 🚀 Funciones\n\n- **alculadora de COP y eficiencia:** Introdujo un completo motor de cálculo del COP (coeficiente de rendimiento) para rastrear la eficiencia de las bombas de calor. \n- **oporte externo de contadores inteligentes:** Los usuarios ahora pueden optar por usar estimaciones internas de Luxtronik o vincular sensores externos de alta precisión (por ejemplo, contadores de calor Shelly 3EM o M-Bus) a través de ID de objeto de ioBroker para el consumo de energía y la generación de energía térmica. \n- **étricas granulares:** El adaptador ahora analiza dinámicamente el estado operativo activo para dividir y calcular los valores de COP diarios de «total», «calefacción» y «agua caliente» de forma independiente. \n- **ersistent Time Rollovers:** Se implementó un sólido sistema de «instantáneas» con contadores virtuales absolutos. El adaptador detecta automáticamente las transferencias de días, meses y años para conservar los datos y garantizar cálculos precisos a largo plazo, incluso al reiniciar el adaptador o ioBroker. \n- **nterfaz de eficiencia dedicada:** Se ha añadido una nueva pestaña de configuración «Eficiencia/COP» para gestionar fácilmente las fuentes de datos de energía y cambiar el motor de cálculo. \n- **stado de conexión y sondeo:** Se ha añadido un nuevo punto de datos del sistema Info.LastUpdate Este estado rastrea continuamente la fecha exacta de la última recuperación exitosa de datos, lo que facilita la monitorización del estado del adaptador y la actividad de sondeo en visualizaciones como VIS o Lovelace. \n\n#### 🛠 Corrección de errores y mejoras\n\n- **reación del árbol de objetos:** Se solucionó un problema por el que no se creaban cubos de datos ocultos para el cálculo del COP porque faltaban los directorios principales. \n- **ormato de marca de hora:** Se resolvió un error estricto de discordancia de tipos en el registro de IOBroker al formatear correctamente `info.LastUpdate` como cadena ISO en lugar de marca de hora numérica. \n- **ropiedades del estado y calidad del código:** Se han resuelto las advertencias estrictas de TypeScript y ESLint (faltan anotaciones de JSDoc, definiciones de objetos de lectura/escritura) en el nuevo gestor de COP. \n- **PI de IOBroker modernizada:** Se sustituyeron las llamadas al método `setStateAsync` obsoletas por el moderno estándar `setState` basado en promesas en el motor de cálculo de COP. \n- **lasificación de la interfaz de usuario:** Se aseguró de que las pestañas de configuración recién generadas mantengan un orden lógico y coherente en las recompilaciones \n- **apeo interno:** Reestructuró el mapeo de carpetas «info» para incluir sin problemas los metadatos del adaptador y la telemetría del hardware. ",
80
- "pl": "#### 🚀 Funkcje\n\n- **alkulator COP i wydajności:** Wprowadzono kompleksowy silnik obliczeniowy COP (współczynnik wydajności) do śledzenia wydajności pompy ciepła. \n- **bsługa zewnętrznych inteligentnych liczników:** Użytkownicy mogą teraz wybrać użycie wewnętrznych szacunków Luxtronik lub połączyć precyzyjne czujniki zewnętrzne (np. ciepłomierze Shelly 3EM lub M-Bus) za pomocą identyfikatorów obiektów ioBroker do zużycia energii i wytwarzania energii cieplnej. \n- **ranular Live Metrics:** Adapter teraz dynamicznie analizuje aktywny stan pracy, aby niezależnie podzielić i obliczyć bieżące dzienne wartości COP dla „Całkowita”, „Ogrzewanie” i „Gorąca woda”. \n- **rwałe przewracania czasu:** Zaimplementowano solidny system „migawki” z absolutnymi wirtualnymi licznikami. Adapter automatycznie wykrywa zmiany w dniu, miesiącu i roku, aby zachować dane i zagwarantować dokładne obliczenia długoterminowe, nawet podczas ponownego uruchamiania adaptera lub ponownego uruchamiania systemu iOBroker. \n- **edykowany interfejs efektywności:** Dodano nową zakładkę konfiguracji „Efektywność/COP”, aby łatwo zarządzać źródłami danych energii i przełączać silnik obliczeniowy. \n- **tatus połączenia i głosowania:** Dodano nowy punkt danych systemowych `Info.lastUpdate`. Ten stan stale śledzi dokładny znacznik czasu ostatniego pomyślnego pobierania danych, co ułatwia monitorowanie stanu adaptera i aktywności ankietowania w wizualizacjach, takich jak VIS lub Lovelace. \n\n#### 🛠 Poprawki błędów i ulepszenia\n\n- **worzenie drzewa obiektów:** Naprawiono błąd, który powodował, że ukryte wiadra danych dla obliczeń COP nie były tworzone, ponieważ brakowało katalogów nadrzędnych. \n- **ormatowanie znacznika czasowego:** Rozwiązano błąd ścisłego niedopasowania typu w dzienniku ioBroker poprzez poprawne sformatowanie `info.lastUpdate` jako ciąg znaku ISO zamiast numerycznego znacznika czasowego. \n- **łaściwości stanu i jakość kodu:** Rozwiązano ścisłe ostrzeżenia TypeScript i eSlint (brak adnotacji JSDoc, brakujące definicje obiektów odczytu/zapisu) w nowym menedżerze COP. \n- **modernizowany interfejs API ioBroker:** Zastąpiono przestarzałe wywołania metody `setStateSync` nowoczesnym, opartym na obietnicach standardem `setState` w całym silniku obliczeniowym COP. \n- **ortowanie interfejsu użytkownika konfiguracji:** Zapewniono, że nowo wygenerowane karty konfiguracji zachowują logiczną i spójną kolejność podczas przebudowy. \n- **apowanie wewnętrzne:** Zmieniono strukturę mapowania folderów `info`, aby pomieścić metadane na poziomie adaptera wraz ze sprzętową telemetrią. ",
81
- "uk": "#### 🚀 Особливості\n\n- **алькулятор COP та ефективності:** Введено комплексний розрахунковий двигун COP (коефіцієнт продуктивності) для відстеження ефективності теплового насоса. \n- **ідтримка зовнішнього розумного лічильника:** Тепер користувачі можуть використовувати внутрішні оцінки Luxtronik або зв'язати високоточні зовнішні датчики (наприклад, лічильники тепла Shelly 3EM або M-Bus) через ідентифікатори об'єктів IObroker для споживання енергії та генерації теплової енергії. \n- **ранульовані показники в реальному часі:** Тепер адаптер динамічно аналізує активний робочий стан, щоб розділити та обчислити щоденні значення COP в реальному часі для «Total», «Heating» та «Hot Water» незалежно. \n- **остійні перекиди часу:** Реалізована надійна система «знімків» з абсолютними віртуальними лічильниками. Адаптер автоматично визначає переломи дня, місяця та року, щоб зберегти дані та гарантувати точні довгострокові розрахунки навіть під час перезапуску адаптера або перезавантаження IObroker. \n- **пеціальний інтерфейс ефективності:** Додано нову вкладку конфігурації «Ефективність/ COP» для легкого управління джерелами даних про енергію та перемикання обчислювального механізму. \n- **татус підключення та опитування:** Додано нову системну точку даних `Info.lastUpdate`. Цей стан безперервно відстежує точну мітку часу останнього успішного пошуку даних, що полегшує моніторинг стану адаптера та активності опитування у візуалізаціях, таких як VIS або Lovelace. \n\n#### 🛠 Виправлення помилок та вдосконалення\n\n- **творення дерева об'єктів:** Виправлена проблема, коли приховані відра даних для обчислення COP не створювалися, оскільки батьківські каталоги відсутні. \n- **орматування міток часу:** Вирішено сувору помилку невідповідності типів у журналі IObroker шляхом правильного форматування `Info.lastUpdate` як рядок ISO замість числової мітки часу. \n- **ластивості стану та якість коду:** Вирішено суворі попередження TypeScript та ESLint (відсутні анотації JSDoc, відсутні визначення об'єктів читання/запису) у новому менеджері COP. \n- **одернізований API IObroker:** Замінено застарілі виклики методу `SetStateAsync` сучасним стандартом `SetState`, заснованим на обіцянках, у системі обчислення COP. \n- **ортування інтерфейсу конфігурації:** Забезпечено, що нещодавно створені вкладки конфігурації підтримують логічний та послідовний порядок у перебудовах. \n- **нутрішнє відображення:** Реструктуризовано відображення папок `info` для чистого розміщення метаданих рівня адаптера поряд із апаратною телеметрією. ",
82
- "zh-cn": "#### 🚀 功能\n\n-**COP 和效率计算器:** 引入了全面的 COP(性能系数)计算引擎来跟踪热泵效率。\n-**外部智能电表支持:**用户现在可以选择使用Luxtronik内部估算值或通过IOBroker对象ID连接高精度外部传感器(例如Shelly 3EM或M-Bus热量表),用于功耗和热能发电。\n-**精细实时指标:**适配器现在可以动态分析活动运行状态,以单独拆分和计算 “总计”、“供热” 和 “热水” 的每日实时COP值。\n-**持续时间翻转:**使用绝对虚拟计数器实现了强大的 “快照” 系统。即使在适配器重启或 IOBroker 重启期间,适配器也会自动检测日、月和年的滚动以保存数据并保证长期计算的准确性。\n-**专用效率用户界面:**添加了新的 “效率/COP” 配置选项卡,可轻松管理能源数据源和切换计算引擎。\n-**连接和轮询状态:** 添加了新的系统数据点 `info.lastUpdate`。这种状态会持续跟踪上次成功检索数据的确切时间戳,从而可以轻松地在 VIS 或 Lovelace 等可视化中监控适配器的运行状况和轮询活动。\n\n#### 🛠 错误修复和增强\n\n-**创建对象树:**修复了由于缺少父目录而未创建用于 COP 计算的隐藏数据桶的问题。\n-**时间戳格式:**通过将`info.lastUpdate`正确格式化为ISO字符串而不是数字时间戳,解决了IOBroker日志中严重的类型不匹配错误。\n-**状态属性和代码质量:** 解决了新 COP 管理器中严格的 TypeScript 和 ESLint 警告(缺少 JSDoc 注释、缺少读/写对象定义)。\n-**现代化的 ioBroker API:** 将整个 COP 计算引擎中过时的 “setStateAsync” 方法调用替换为基于承诺的现代 “setState” 标准。\n-**Config UI 排序:** 确保新生成的配置选项卡在重建过程中保持逻辑一致的顺序。\n-**内部映射:**重组了 “info” 文件夹映射,以完全容纳适配器级元数据和硬件遥测。"
83
- },
84
- "0.16.1": {
85
- "en": "#### 🚀 Features\n\n- **Enhanced UI Layout:** Improved the \"Datapoints\" settings tab layout to display up to 4 items side-by-side on larger screens for a better overview and improved usability.\n\n#### 🛠 Bugfixes & Enhancements\n\n- **State Cleanup Logic Fixed:** Resolved an issue where unchecked datapoints (e.g., Room Thermostats) were not removed from the ioBroker object tree. The `isStateEnabled` logic now correctly handles `undefined` config states for dynamically generated checkboxes.",
86
- "de": "#### 🚀 Merkmale\n\n- **erbessertes UI-Layout:** Das Tab-Layout „Datenpunkte“ wurde verbessert, sodass bis zu 4 Elemente übersichtlicher und benutzerfreundlicher angezeigt werden. \n\n#### 🛠 Bugfixes & Verbesserungen\n\n- **tate Cleanup Logic behoben:** Ungeprüfte Datenpunkte (z. B. Raumthermostate) wurden nicht aus dem ioBroker-Objektbaum entfernt. Die `isStateEnabled`-Logik behandelt jetzt `undefinierte` Konfigurationsstatus für dynamisch generierte Checkboxen. ",
87
- "ru": "#### 🚀 Функции\n\n- **лучшенная компоновка пользовательского интерфейса:** Улучшена компоновка вкладок настроек «Datapoints»: теперь на больших экранах можно отображать до 4 объектов рядом друг с другом для лучшего обзора и удобства использования. \n\n#### 🛠 Исправления ошибок и улучшения\n\n- **справлена логика очистки состояния:** Устранена проблема, из-за которой непроверенные точки данных (например, комнатные термостаты) не удалялись из дерева объектов IOBroker. Логика IsStateEnabled теперь корректно обрабатывает «неопределенное» состояние конфигурации динамически генерируемых флажков. ",
88
- "pt": "#### 🚀 Recursos\n\n- **ayout de UI aprimorado:** O layout da guia “Pontos de dados” foi aprimorado para exibir até 4 itens lado a lado em telas maiores para melhor visão geral e usabilidade. \n\n#### 🛠 Correções e melhorias\n\n- **ógica de limpeza de estado corrigida:** Resolveu um problema que impedia a remoção de pontos de dados não verificados da árvore de objetos IOBroker. A lógica `isStateEnabled` agora trata corretamente os estados `undefined` para checkboxes gerados dinamicamente. ",
89
- "nl": "#### 🚀 Kenmerken\n\n- **erbeterde UI-indeling:** Verbeterde tabindeling met instellingen voor „Datapunten” om tot 4 items naast elkaar weer te geven op grotere schermen voor een beter overzicht en verbeterde bruikbaarheid. \n\n#### 🛠 Oplossingen en verbeteringen\n\n- **tate Cleanup Logic opgelost:** Er is een probleem opgelost waarbij niet-aangevinkte datapunten (bijvoorbeeld kamerthermostaten) niet werden verwijderd uit de objectenstructuur van IOBroker. De `IsStateEnabled` logica verwerkt nu correct `ongedefinieerde` configuratiestatussen voor dynamisch gegenereerde selectievakjes. ",
90
- "fr": "#### 🚀 Fonctions\n\n- **Interface utilisateur améliorée :** La disposition de l'onglet « Points de données » a été améliorée pour afficher jusqu'à 4 éléments côte à côte sur des écrans plus grands.\n\n#### 🛠 Corrections et améliorations\n\n- **State Cleanup Logic a été corrigée :** Problème résolu : les points de données non cochés (thermostats d'ambiance, par exemple) n'étaient pas supprimés. La logique « IsStateEnabled » gère désormais correctement les états de configuration « indéfinis » des cases à cocher.",
91
- "it": "#### 🚀 Funzioni\n\n- **ayout dell'interfaccia utente migliorato:** La scheda «Datapoints» mostra fino a 4 elementi fianco a fianco su schermi più grandi per una migliore panoramica e usabilità. \n\n#### 🛠 Bug fix e migliorie\n\n- **tate Cleanup Logic Fixed:** Risolto un problema che impediva la rimozione dei datapoint non controllati dall'albero degli oggetti IOBroker. La logica `isStateEnabled` ora gestisce correttamente gli stati di configurazione indefiniti per le caselle dinamiche. ",
92
- "es": "#### 🚀 Funciones\n\n- **iseño de interfaz de usuario mejorado:** Se ha mejorado el diseño de las pestañas de «Puntos de datos» para mostrar hasta 4 elementos uno al lado del otro en pantallas grandes, lo que mejora la usabilidad. \n\n#### 🛠 Corrección de errores y mejoras\n\n- **e corrigió la lógica de limpieza del estado:** Se resolvió un problema por el que los puntos de datos no marcados (p. ej., los termostatos de sala) no se eliminaban del árbol de objetos de ioBroker. La lógica `isStateEnabled` gestiona ahora correctamente los estados de configuración «indefinidos» de las casillas generadas dinámicamente. ",
93
- "pl": "#### 🚀 Funkcje\n\n- **lepszony układ interfejsu użytkownika:** Ulepszono układ zakładki ustawień „Punkty danych”, aby wyświetlać do 4 elementów obok siebie na większych ekranach, aby uzyskać lepszy przegląd i lepszą użyteczność. \n\n#### 🛠 Poprawki błędów i ulepszenia\n\n- **aprawiono logikę czyszczenia stanu:** Rozwiązano problem polegający na tym, że niezaznaczone punkty danych (np. termostaty pokojowe) nie zostały usunięte z drzewa obiektów ioBroker. Logika `IsStateEnabled` poprawnie obsługuje stany konfiguracji `undefinied` dla dynamicznie generowanych pól wyboru. ",
94
- "uk": "#### 🚀 Особливості\n\n- **Розширений макет інтерфейсу користувача:** Покращено макет вкладки налаштувань «Datappoints» для відображення до 4 елементів поруч на великих екранах для кращого огляду та покращення зручності використання. \n\n#### 🛠 Виправлення помилок та вдосконалення\n\n- **огіка очищення стану виправлена:** Вирішено проблему, через яку неперевірені точки даних (наприклад, кімнатні термостати) не були видалені з дерева об'єктів IObroker. Логіка `IsStateEnabled` тепер правильно обробляє стани конфігурації `undefined` для динамічно створених прапорців. ",
95
- "zh-cn": "#### 🚀 功能\n\n-**增强的用户界面布局:**改进了 “DataPoints” 设置选项卡布局,可在较大的屏幕上并排显示多达 4 个项目,以提供更好的概览和更高的可用性。\n\n#### 🛠 错误修复和增强\n\n-**状态清理逻辑已修复:** 解决了未选中的数据点(例如房间恒温器)未从 IOBroker 对象树中移除的问题。现在,`isStateEnabled` 逻辑可以正确处理动态生成的复选框的 “未定义” 配置状态。"
96
96
  }
97
97
  },
98
98
  "titleLang": {
@@ -156,7 +156,7 @@
156
156
  },
157
157
  "dependencies": [
158
158
  {
159
- "js-controller": ">=6.0.11"
159
+ "js-controller": ">=7.0.7"
160
160
  }
161
161
  ],
162
162
  "globalDependencies": [
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "iobroker.luxtronik2-controller",
3
- "version": "0.18.1",
3
+ "version": "0.19.0",
4
4
  "description": "Zugriff und Steuerung von Wärmepumpen mit einer Luxtronik 2.x Steuereinheit",
5
5
  "author": {
6
6
  "name": "TbsJah",
@@ -29,8 +29,9 @@
29
29
  },
30
30
  "dependencies": {
31
31
  "@iobroker/adapter-core": "^3.4.3",
32
+ "modbus-serial": "^8.0.25",
32
33
  "node-schedule": "^2.1.1",
33
- "ws": "^8.21.3"
34
+ "ws": "^8.22.0"
34
35
  },
35
36
  "devDependencies": {
36
37
  "@alcalzone/release-script": "^5.2.1",
@@ -40,10 +41,10 @@
40
41
  "@iobroker/adapter-dev": "^1.5.0",
41
42
  "@iobroker/dev-server": "^0.8.0",
42
43
  "@iobroker/eslint-config": "^2.3.4",
43
- "@iobroker/testing": "^6.3.0",
44
+ "@iobroker/testing": "^6.3.1",
44
45
  "@tsconfig/node22": "^22.0.6",
45
46
  "@types/iobroker": "npm:@iobroker/types@^7.2.2",
46
- "@types/node": "^22.0.0",
47
+ "@types/node": "^26.6.5",
47
48
  "@types/node-schedule": "^2.1.8",
48
49
  "rimraf": "^6.1.3",
49
50
  "source-map-support": "^0.5.21",