iobroker.luxtronik2-controller 0.15.0 → 0.16.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/README.md +20 -13
- package/admin/jsonConfig.json +7701 -572
- package/build/mapping/info.js +1 -2
- package/build/mapping/info.js.map +2 -2
- package/build/objectManager.js +9 -7
- package/build/objectManager.js.map +2 -2
- package/build/scripts/generateConfig.js +145 -0
- package/build/scripts/generateConfig.js.map +7 -0
- package/io-package.json +27 -27
- package/package.json +5 -4
package/README.md
CHANGED
|
@@ -85,6 +85,26 @@ Bug reports, compatibility notes for specific firmware versions, or feature requ
|
|
|
85
85
|
## Changelog
|
|
86
86
|
|
|
87
87
|
// ### **WORK IN PROGRESS**
|
|
88
|
+
### 0.16.0 (2026-10-11)
|
|
89
|
+
|
|
90
|
+
#### 🚀 Features
|
|
91
|
+
|
|
92
|
+
- **Dynamic Admin UI Generation:** The "Datapoints / Objects" configuration tab in the adapter settings is now fully auto-generated during the build process (`prebuild`). This ensures the UI is always 100% in sync with the underlying TypeScript state mappings.
|
|
93
|
+
- **Category Master Switches:** Added master toggle switches to the adapter settings. Users can now enable or disable entire hardware categories (e.g., Solar, Cooling, Ventilation) with a single click. This keeps the ioBroker object tree clean and significantly reduces unnecessary polling for unused features.
|
|
94
|
+
- **Dynamic Protection for Critical States:** System-critical datapoints are now protected dynamically via a `required: true` flag in the codebase. They are permanently locked (grayed out) in the UI and cannot be accidentally deleted or disabled by the user or the visibility filter.
|
|
95
|
+
|
|
96
|
+
#### 🛠 Bugfixes & Enhancements
|
|
97
|
+
|
|
98
|
+
- **Cycle Optimization Logic (Hot Water):** Fixed a logic flaw where the adapter erroneously applied an artificial hot water target temperature increase while the heat pump was already actively running a hot water cycle. The trigger is now strictly limited to the end of regular heating cycles.
|
|
99
|
+
- **Build Process Optimized:** Integrated the UI generation script (`generateConfig.ts`) seamlessly into the NPM `prebuild` lifecycle, automatically patching the `jsonConfig.json` before typescript compilation.
|
|
100
|
+
|
|
101
|
+
### 0.15.1 (2026-10-10)
|
|
102
|
+
|
|
103
|
+
#### 🛠 Bugfixes & Enhancements
|
|
104
|
+
|
|
105
|
+
- **Admin UI (ZIP Control):** Completely revised the explanatory text for the Circulation Pump (ZIP) settings in `jsonConfig.json`. Clarified the exact behavior of the "Disable base ZIP values" (`zip_lWP_aktiv`) option to prevent unintentional power cuts to external Wi-Fi relays (like Shelly) while maintaining EEPROM hardware protection.
|
|
106
|
+
- **Testing Framework:** Updated `@iobroker/testing` to version 6.3.0 to meet current repository standards.
|
|
107
|
+
- **Changelog Formatting:** Fixed Markdown header formatting to comply with ioBroker "Test and Release" requirements.
|
|
88
108
|
|
|
89
109
|
### 0.15.0 (2026-10-10)
|
|
90
110
|
|
|
@@ -130,19 +150,6 @@ As soon as the adapter detects firmware V1.90.x or V2.90.x, **all write commands
|
|
|
130
150
|
- **Adapter Configuration (UI):** Removed outdated warning labels regarding the "Hide unsupported parameters" checkbox, as this feature is now completely stable across all controller generations.
|
|
131
151
|
- **Network / WebSocket:** The experimental password transmission for port 8214 has been completely removed, as the communication issue was proven to be caused by the manufacturer's firmware bug. The WebSocket connection for genuine V3.x firmwares operates cleanly again using the proven standard handshake.
|
|
132
152
|
|
|
133
|
-
### 0.13.1 (2026-10-02)
|
|
134
|
-
|
|
135
|
-
- **Fix (Circulation/ZIP):** Fixed a bug where the `Virtual_ZIP_Status` datapoint would remain stuck on `true` when using external relays (e.g., Shelly), even though the hardware relay was correctly turned off. The state reset logic has been decoupled and is now guaranteed to execute, ensuring the ioBroker interface stays perfectly synchronized with the actual hardware state.
|
|
136
|
-
|
|
137
|
-
### 0.13.0 (2026-10-02)
|
|
138
|
-
|
|
139
|
-
- **Bugfixes:**
|
|
140
|
-
- **Critical DHW Target Fix:** Fixed an issue where the hot water target temperature was incorrectly written to parameter 2 instead of 105. This resolves unexpected temperature jumps (e.g., to 65°C) and socket timeouts on various heat pump models.
|
|
141
|
-
- **Write Queue Timeout:** Added a maximum wait timeout to the write queue lock for legacy V1.x firmware to prevent potential infinite loops during read-write collisions.
|
|
142
|
-
- **Backup Manager Multi-Instance Fix:** The automated DTA backup cron job is now safely scoped to the specific adapter instance, preventing conflicts when running multiple heat pumps on the same ioBroker host.
|
|
143
|
-
- **Under the Hood / Refactoring:**
|
|
144
|
-
- **Centralized Typings:** Completely refactored the TypeScript architecture by introducing a centralized `LuxtronikAdapter` interface (`types.ts`). Replaced all fragmented, local interfaces across sub-modules to ensure strict, project-wide type safety and better maintainability.
|
|
145
|
-
|
|
146
153
|
## License
|
|
147
154
|
|
|
148
155
|
MIT License
|