iobroker.luxtronik2-controller 0.1.5 → 0.2.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/README.md CHANGED
@@ -4,8 +4,6 @@
4
4
 
5
5
  [![NPM version](https://img.shields.io/npm/v/iobroker.luxtronik2-controller.svg)](https://www.npmjs.com/package/iobroker.luxtronik2-controller)
6
6
  [![Downloads](https://img.shields.io/npm/dm/iobroker.luxtronik2-controller.svg)](https://www.npmjs.com/package/iobroker.luxtronik2-controller)
7
- ![Number of Installations](https://iobroker.live/badges/luxtronik2-controller-installed.svg)
8
- ![Current version in stable repository](https://iobroker.live/badges/luxtronik2-controller-stable.svg)
9
7
 
10
8
  [![NPM](https://nodei.co/npm/iobroker.luxtronik2-controller.png?downloads=true)](https://nodei.co/npm/iobroker.luxtronik2-controller/)
11
9
 
@@ -19,29 +17,77 @@ Dieser ioBroker-Adapter ermöglicht die lokale Steuerung und Überwachung von W
19
17
 
20
18
  Dieses Projekt baut auf den Vorarbeiten bestehender Open-Source-Projekte auf. Ein besonderer Dank geht an:
21
19
 
20
+ [Bouni](https://github.com/bouni/luxtronik-2) Dessen Pionierarbeit und Code-Entwicklungen die wesentliche Grundlage für die Kommunikation mit Luxtronik-Steuerungen darstellen.
21
+
22
22
  [Coolchip:](https://github.com/coolchip/luxtronik2) Für das grundlegende Reverse-Engineering des Luxtronik-Netzwerkprotokolls.
23
+
23
24
  [UncleSamSwiss:](https://github.com/UncleSamSwiss/ioBroker.luxtronik2) Für den ursprünglichen ioBroker-Adapter.
24
25
 
25
26
  Neuerungen in dieser Version: Der luxtronik2-controller integriert die TCP-Kommunikation (Port 8888 / 8889) nativ und verzichtet auf externe Bibliotheken. Zusätzlich wurden steuernde Makros, eine Logik zur Verdichterschonung sowie ein automatisiertes Datenpunkt-Management implementiert.
26
27
 
28
+ ## Features
29
+
30
+ - Native TCP-Kommunikation: Direkte Verbindung zur Wärmepumpe ohne zusätzlichen Overhead.
31
+
32
+ - Verdichter-Schonung (Takt-Optimierung): Zusammenlegung von Heiz- und Warmwasserzyklen zur Reduzierung der Verdichterstarts.
33
+
34
+ - Integrierte Aktionen (Makros): Vordefinierte Steuerungslogiken für Zwangsheizen, Warmwasseranforderung und die Zirkulationspumpe (ZIP) inkl. automatischem Rückfall auf Standardwerte.
35
+
36
+ - Benutzerdefinierte Datenpunkte: Messwerte (Index 3004) und Parameter (Index 3003) können über die Adapter-Konfiguration hinzugefügt werden. Unix-Zeitstempel werden automatisch formatiert.
37
+
38
+ - Automatisches Objekt-Management: Abgewählte oder gelöschte Datenpunkte und leere Ordnerstrukturen werden bei einem Adapter-Neustart automatisch aus ioBroker entfernt.
39
+
40
+ - Benachrichtigungssystem: Fehlercodes der Wärmepumpe können direkt an Telegram oder das ioBroker-Benachrichtigungssystem gesendet werden.
41
+
42
+ - Bewegungsmelder-Kopplung: Möglichkeit zur bedarfsgesteuerten Aktivierung der Zirkulationspumpe über vorhandene ioBroker-Bewegungssensoren.
43
+
44
+ ## ⚠️ Warnung
45
+
46
+ Einige Einstellungen, die durch diese Integration bereitgestellt werden, können die Leistung deiner Wärmepumpe beeinträchtigen. Fehlkonfigurationen können dazu führen, dass der Regler in einen Fehlerzustand wechselt, was einen manuellen Reset vor Ort erfordert.
47
+
48
+ Dieses Projekt zielt darauf ab, deine Wärmepumpe zu schützen, indem die Konfigurationsmöglichkeiten auf sichere Werte beschränkt werden. Es können jedoch keine Garantien übernommen werden. Bitte sei vorsichtig, ziehe dein Luxtronik-Handbuch zurate und ändere keine Einstellungen, die du nicht vollständig verstehst.
49
+
50
+ ## 🔧 Kompatibilität
51
+
52
+ Die Integration ermöglicht es dir, Wärmepumpen mit einem Luxtronik2-Regler zu überwachen und zu steuern. Sie funktioniert **lokal ohne Internetzugang**.
53
+ Getestet wurde und wird mit einer LWD50A (LD5) von Alpha Innotec.
54
+
27
55
  ## ⚠️ Disclaimer / Haftungsausschluss ⚠️
28
56
 
29
57
  Dieses Projekt steht in keinerlei Verbindung zu Alpha Innotec, Novelan, ait-deutschland GmbH oder anderen Herstellern. Es handelt sich um ein privates Open-Source-Projekt, das in der Freizeit entwickelt und gepflegt wird. Die Nutzung des Adapters geschieht auf eigene Gefahr.
30
58
 
31
59
  _This project is not affiliated with Alpha Innotec, Novelan, ait-deutschland GmbH, or any other company. It is a personal project that is maintained in spare time. Use at your own risk._
32
60
 
33
- ## Developer manual
61
+ ## Fehler melden & Mitwirken
62
+
63
+ Fehlerberichte, Kompatibilitätshinweise zu speziellen Firmware-Versionen oder Feature-Anfragen können über den Issue-Tracker im [GitHub-Repository](https://github.com/TbsJah/ioBroker.luxtronik2-controller/issues) eingereicht werden.
64
+
65
+ ## Information
66
+
67
+ [Info Deutsch](documentation/readme_de.md)
68
+
69
+ [Info English](documentation/readme_en.md)
70
+
71
+ <img src="documentation/Bilder/Haupteinstellung.png" alt="Haupteinstellung" width="100%">
72
+ <img src="documentation/Bilder/Objekte.png" alt="Objekte" width="100%">
73
+ <img src="documentation/Bilder/Datenpunkte.png" alt="Datenpunkte" width="100%">
74
+ <img src="documentation/Bilder/Benachrichtigung.png" alt="Benachrichtigung" width="100%">
75
+ <img src="documentation/Bilder/EigeneWerte.png" alt="EigeneWerte" width="100%">
76
+ <img src="documentation/Bilder/Fehlermeldung.png" alt="Fehlermeldung" width="100%">
77
+ <img src="documentation/Bilder/Bewegungssensoren.png" alt="Bewegungssensoren" width="100%">
34
78
 
35
79
  // ### **WORK IN PROGRESS**
36
- Readme - deutsch
37
- Readme - english
80
+ ### 0.2.0 (2026-07-09)
81
+
82
+ - Readme - deutsch
83
+
38
84
  ### 0.1.5 (2026-07-09)
39
85
 
40
- ' Update Zip
86
+ - Update Zip
41
87
 
42
88
  ### 0.1.4 (2026-07-09)
43
89
 
44
- - NPM
90
+ - Eigene States
45
91
 
46
92
  ### 0.1.3 (2026-07-09)
47
93
 
@@ -49,7 +95,7 @@ Readme - english
49
95
 
50
96
  ### 0.1.2 (2026-07-09)
51
97
 
52
- NPM Freigabe
98
+ - NPM Freigabe
53
99
 
54
100
  ### 0.1.1 (2026-07-09)
55
101
 
@@ -57,7 +103,7 @@ NPM Freigabe
57
103
 
58
104
  ### 0.1.0 (2026-07-09)
59
105
 
60
- - (TbsJah) initial release
106
+ - initial release
61
107
 
62
108
  ## License
63
109
 
@@ -139,7 +139,6 @@
139
139
  "label": "ZIP Dauer an (s)",
140
140
  "sm": 12,
141
141
  "md": 4,
142
- "disabled": "data.regelung_aktiv === false",
143
142
  "default": 120
144
143
  },
145
144
  "zip_last_run_min": {
@@ -147,7 +146,6 @@
147
146
  "label": "ZIP Dauer aus (s)",
148
147
  "sm": 12,
149
148
  "md": 4,
150
- "disabled": "data.regelung_aktiv === false",
151
149
  "default": 600
152
150
  },
153
151
  "zip_aktiv_ww": {
@@ -155,7 +153,6 @@
155
153
  "label": "ZIP Dauer bei Warmwassererzeugung (s)",
156
154
  "sm": 12,
157
155
  "md": 4,
158
- "disabled": "data.regelung_aktiv === false",
159
156
  "default": 600
160
157
  }
161
158
  }
package/io-package.json CHANGED
@@ -1,8 +1,21 @@
1
1
  {
2
2
  "common": {
3
3
  "name": "luxtronik2-controller",
4
- "version": "0.1.5",
4
+ "version": "0.2.0",
5
5
  "news": {
6
+ "0.2.0": {
7
+ "en": "Readme - deutsch",
8
+ "de": "Readme - deutsch",
9
+ "ru": "Readme - немецкий",
10
+ "pt": "Leia-me - alemão",
11
+ "nl": "Readme - deutsch",
12
+ "fr": "Lisez-moi - allemand",
13
+ "it": "Leggimi - tedesco",
14
+ "es": "Léame - alemán",
15
+ "pl": "Readme - niemiecki",
16
+ "uk": "Readme - німецькою мовою",
17
+ "zh-cn": "自述文件 - 德语"
18
+ },
6
19
  "0.1.5": {
7
20
  "en": "' Update Zip",
8
21
  "de": "'Zip aktualisieren'",
@@ -80,19 +93,6 @@
80
93
  "pl": "wydanie początkowe",
81
94
  "uk": "початковий випуск",
82
95
  "zh-cn": "初始版本"
83
- },
84
- "0.0.1": {
85
- "en": "initial release",
86
- "de": "Erstveröffentlichung",
87
- "ru": "Начальная версия",
88
- "pt": "lançamento inicial",
89
- "nl": "Eerste uitgave",
90
- "fr": "Première version",
91
- "it": "Versione iniziale",
92
- "es": "Versión inicial",
93
- "pl": "Pierwsze wydanie",
94
- "uk": "Початкова версія",
95
- "zh-cn": "首次出版"
96
96
  }
97
97
  },
98
98
  "titleLang": {
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "iobroker.luxtronik2-controller",
3
- "version": "0.1.5",
3
+ "version": "0.2.0",
4
4
  "description": "Zugriff und Steuerung von Wärmepumpen mit einer Luxtronik 2.x Steuereinheit",
5
5
  "author": {
6
6
  "name": "TbsJah",