iobroker.eos-admin 9.0.18 → 9.0.20

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (615) hide show
  1. package/NEXOWATT_EOS_BUILD_INFO.json +8 -9
  2. package/README.md +7 -3
  3. package/START_HIER_9.0.19.md +52 -0
  4. package/START_HIER_9.0.20.md +65 -0
  5. package/adminWww/.vite/manifest.json +114 -114
  6. package/adminWww/NEXOWATT_EOS_FRONTEND_MANIFEST.json +13762 -13761
  7. package/adminWww/assets/{AdapterUpdateDialog-ByJk9Cxj.js → AdapterUpdateDialog-CRD3XVom.js} +1 -1
  8. package/adminWww/assets/{Adapters-V2JtEPZX.js → Adapters-Cuf0X0CU.js} +1 -1
  9. package/adminWww/assets/{ConfigManager-BKcdyJnN.js → ConfigManager-B8ycQt1C.js} +1 -1
  10. package/adminWww/assets/{Enums-ChbfAWzp.js → Enums-CctVCgZX.js} +1 -1
  11. package/adminWww/assets/{Fields-DzaVXEvg.js → Fields-onm4DfoO.js} +1 -1
  12. package/adminWww/assets/{Files-CRpIXj4X.js → Files-OLP3Rwc7.js} +1 -1
  13. package/adminWww/assets/{Hosts-rOgfd2wo.js → Hosts-C31oqMcW.js} +1 -1
  14. package/adminWww/assets/{Instances-BxLhJ6Pb.js → Instances-DFdvJ9pa.js} +1 -1
  15. package/adminWww/assets/{Intro-BOql527d.js → Intro-DvsFJxU0.js} +1 -1
  16. package/adminWww/assets/{Logs-WUUDY7a4.js → Logs-Zqg2Bqv6.js} +1 -1
  17. package/adminWww/assets/{Objects-DYaZkCK7.js → Objects-CpWZp6yp.js} +1 -1
  18. package/adminWww/assets/{Overview-C6hiiPbm.js → Overview-BsKUo298.js} +1 -1
  19. package/adminWww/assets/{State-AH43l7fG.js → State-D_xwlhhb.js} +1 -1
  20. package/adminWww/assets/{UsedResources-jhsRMH4X.js → UsedResources-C79N6yZx.js} +1 -1
  21. package/adminWww/assets/{Users-D9wyLyJ1.js → Users-WgC0O8P0.js} +1 -1
  22. package/adminWww/assets/{bootstrap-gVLo1K_2.js → bootstrap-BcfBoIoa.js} +3 -3
  23. package/adminWww/assets/{hostInit-Dt_M-NAC.js → hostInit-B7bBV7cH.js} +1 -1
  24. package/adminWww/assets/icons/nexowatt-180.png +0 -0
  25. package/adminWww/assets/{icons-material-DuVW_EUA.js → icons-material-D1JYmRTj.js} +1 -1
  26. package/adminWww/assets/{index-B1cnPkSO.js → index-DbiuoDjo.js} +2 -2
  27. package/adminWww/assets/{installSVGRenderer-GvgHjubR.js → installSVGRenderer-BAY-Pzp-.js} +1 -1
  28. package/adminWww/assets/{mf-entry-bootstrap-0-6b32b635.js → mf-entry-bootstrap-0-33384c20.js} +2 -2
  29. package/adminWww/index.html +24 -24
  30. package/adminWww/mf-manifest.json +1 -1
  31. package/adminWww/mf-stats.json +1 -1
  32. package/adminWww/{remoteEntry-eos-9.0.18.js → remoteEntry-eos-9.0.20.js} +1 -1
  33. package/adminWww/remoteEntry.js +1 -1
  34. package/build/lib/eosCookieNamespace.js +12 -2
  35. package/build/lib/eosCookieNamespace.js.map +1 -1
  36. package/build/lib/eosDeviceEmsPlan.js +449 -28
  37. package/build/lib/eosDeviceEmsPlan.js.map +1 -1
  38. package/build/lib/eosDeviceEmsService.js +158 -12
  39. package/build/lib/eosDeviceEmsService.js.map +1 -1
  40. package/build/lib/eosLegacyMigration.js +26 -1
  41. package/build/lib/eosLegacyMigration.js.map +1 -1
  42. package/build/lib/eosModuleHost.js +218 -53
  43. package/build/lib/eosModuleHost.js.map +1 -1
  44. package/build/lib/eosStateSubscriptions.js +59 -2
  45. package/build/lib/eosStateSubscriptions.js.map +1 -1
  46. package/build/lib/web.js +22 -3
  47. package/build/lib/web.js.map +1 -1
  48. package/docs/reports/unified-9.0.19/ALIAS_MESSWERTFRISCHE.md +31 -0
  49. package/docs/reports/unified-9.0.19/COMMISSIONING_PLAN_REVIEW.md +56 -0
  50. package/docs/reports/unified-9.0.19/EMS_ABSCHLUSSREVIEW.md +43 -0
  51. package/docs/reports/unified-9.0.19/EMS_KATEGORIEN_ABDECKUNG.md +66 -0
  52. package/docs/reports/unified-9.0.19/EMS_VERGLEICH_UND_KOPPLUNG.md +25 -0
  53. package/docs/reports/unified-9.0.19/EVCS_STATE_OBJECTS.md +47 -0
  54. package/docs/reports/unified-9.0.19/GERAETE_EMS_EINRICHTUNG.md +100 -0
  55. package/docs/reports/unified-9.0.19/GERAETE_STARTAUSFALL.md +37 -0
  56. package/docs/reports/unified-9.0.19/INSTALLER_LIFECYCLE_REVIEW.md +59 -0
  57. package/docs/reports/unified-9.0.19/LEGACY_REGRESSION_REVIEW.md +42 -0
  58. package/docs/reports/unified-9.0.19/MODBUS_AUTHORIZATION_READS.md +25 -0
  59. package/docs/reports/unified-9.0.19/PRUEFBERICHT.md +56 -0
  60. package/docs/reports/unified-9.0.19/RUNTIME_START_UEBERNAHME.md +33 -0
  61. package/docs/reports/unified-9.0.19/SMA_RECEIVER_LIFECYCLE.md +42 -0
  62. package/docs/reports/unified-9.0.19/STATIC_REVIEW_DE.md +11 -0
  63. package/docs/reports/unified-9.0.19/TARIFF_PRICE_VALUES_REVIEW.md +31 -0
  64. package/docs/reports/unified-9.0.19/TARIF_VIERTELSTUNDEN_RUNTIME.md +17 -0
  65. package/docs/reports/unified-9.0.19/UNABHAENGIGER_REVIEW.md +49 -0
  66. package/docs/reports/unified-9.0.19/raw/INDEX.json +751 -0
  67. package/docs/reports/unified-9.0.19/raw/audit-full.log +345 -0
  68. package/docs/reports/unified-9.0.19/raw/audit-full.result.json +14 -0
  69. package/docs/reports/unified-9.0.19/raw/audit-runtime.log +23 -0
  70. package/docs/reports/unified-9.0.19/raw/audit-runtime.result.json +15 -0
  71. package/docs/reports/unified-9.0.19/raw/backend-final.log +5 -0
  72. package/docs/reports/unified-9.0.19/raw/backend-final.result.json +14 -0
  73. package/docs/reports/unified-9.0.19/raw/devices-hosted-typecheck-node22.log +0 -0
  74. package/docs/reports/unified-9.0.19/raw/devices-hosted-typecheck-node22.result.json +15 -0
  75. package/docs/reports/unified-9.0.19/raw/devices-hosted-typecheck-node24.log +0 -0
  76. package/docs/reports/unified-9.0.19/raw/devices-hosted-typecheck-node24.result.json +15 -0
  77. package/docs/reports/unified-9.0.19/raw/devices-incident-build.log +5 -0
  78. package/docs/reports/unified-9.0.19/raw/devices-incident-host-final.log +70 -0
  79. package/docs/reports/unified-9.0.19/raw/devices-incident-lease-918-before.log +26 -0
  80. package/docs/reports/unified-9.0.19/raw/devices-incident-lease-after.log +9 -0
  81. package/docs/reports/unified-9.0.19/raw/devices-incident-metadata-after.log +11 -0
  82. package/docs/reports/unified-9.0.19/raw/devices-incident-metadata-before.log +28 -0
  83. package/docs/reports/unified-9.0.19/raw/devices-incident-web-pipeline.log +22 -0
  84. package/docs/reports/unified-9.0.19/raw/frontend-build.log +152 -0
  85. package/docs/reports/unified-9.0.19/raw/frontend-build.result.json +14 -0
  86. package/docs/reports/unified-9.0.19/raw/installer-build.log +26 -0
  87. package/docs/reports/unified-9.0.19/raw/installer-build.result.json +14 -0
  88. package/docs/reports/unified-9.0.19/raw/keygen-source.json +6 -0
  89. package/docs/reports/unified-9.0.19/raw/legacy-auto-pv.log +6 -0
  90. package/docs/reports/unified-9.0.19/raw/legacy-auto-pv.result.json +14 -0
  91. package/docs/reports/unified-9.0.19/raw/legacy-charging-grid-cap-clamp.log +6 -0
  92. package/docs/reports/unified-9.0.19/raw/legacy-charging-grid-cap-clamp.result.json +14 -0
  93. package/docs/reports/unified-9.0.19/raw/legacy-charging-grid-cap-safe.log +6 -0
  94. package/docs/reports/unified-9.0.19/raw/legacy-charging-grid-cap-safe.result.json +14 -0
  95. package/docs/reports/unified-9.0.19/raw/legacy-charging-mode-recovery.log +539 -0
  96. package/docs/reports/unified-9.0.19/raw/legacy-charging-mode-recovery.result.json +14 -0
  97. package/docs/reports/unified-9.0.19/raw/legacy-core-limits-phase1.log +6 -0
  98. package/docs/reports/unified-9.0.19/raw/legacy-core-limits-phase1.result.json +14 -0
  99. package/docs/reports/unified-9.0.19/raw/legacy-core-limits-phase2.log +6 -0
  100. package/docs/reports/unified-9.0.19/raw/legacy-core-limits-phase2.result.json +14 -0
  101. package/docs/reports/unified-9.0.19/raw/legacy-core-limits-tariff-final.log +6 -0
  102. package/docs/reports/unified-9.0.19/raw/legacy-core-limits-tariff-final.result.json +14 -0
  103. package/docs/reports/unified-9.0.19/raw/legacy-energy-wallet-final.log +6 -0
  104. package/docs/reports/unified-9.0.19/raw/legacy-energy-wallet-final.result.json +14 -0
  105. package/docs/reports/unified-9.0.19/raw/legacy-farm-dispatch-loader-current.log +2 -0
  106. package/docs/reports/unified-9.0.19/raw/legacy-farm-dispatch-loader-current.result.json +14 -0
  107. package/docs/reports/unified-9.0.19/raw/legacy-final-write-envelope.log +6 -0
  108. package/docs/reports/unified-9.0.19/raw/legacy-final-write-envelope.result.json +14 -0
  109. package/docs/reports/unified-9.0.19/raw/legacy-history-http.log +39 -0
  110. package/docs/reports/unified-9.0.19/raw/legacy-history-http.result.json +15 -0
  111. package/docs/reports/unified-9.0.19/raw/legacy-import-grid-budget.log +30 -0
  112. package/docs/reports/unified-9.0.19/raw/legacy-import-grid-budget.result.json +14 -0
  113. package/docs/reports/unified-9.0.19/raw/legacy-import-grid-contract-current.log +2 -0
  114. package/docs/reports/unified-9.0.19/raw/legacy-import-grid-contract-current.result.json +14 -0
  115. package/docs/reports/unified-9.0.19/raw/legacy-live-mode-loader-current.log +203 -0
  116. package/docs/reports/unified-9.0.19/raw/legacy-live-mode-loader-current.result.json +14 -0
  117. package/docs/reports/unified-9.0.19/raw/legacy-load-grid-sanity.log +6 -0
  118. package/docs/reports/unified-9.0.19/raw/legacy-load-grid-sanity.result.json +14 -0
  119. package/docs/reports/unified-9.0.19/raw/legacy-ocpp-stability.log +6 -0
  120. package/docs/reports/unified-9.0.19/raw/legacy-ocpp-stability.result.json +14 -0
  121. package/docs/reports/unified-9.0.19/raw/legacy-ocpp21-storage-safety.log +6 -0
  122. package/docs/reports/unified-9.0.19/raw/legacy-ocpp21-storage-safety.result.json +14 -0
  123. package/docs/reports/unified-9.0.19/raw/legacy-permanent-grid-protection.log +18 -0
  124. package/docs/reports/unified-9.0.19/raw/legacy-permanent-grid-protection.result.json +14 -0
  125. package/docs/reports/unified-9.0.19/raw/legacy-storage-dp-persistence.log +6 -0
  126. package/docs/reports/unified-9.0.19/raw/legacy-storage-dp-persistence.result.json +14 -0
  127. package/docs/reports/unified-9.0.19/raw/legacy-storage-farm-dispatch-recovery.log +16 -0
  128. package/docs/reports/unified-9.0.19/raw/legacy-storage-farm-dispatch-recovery.result.json +14 -0
  129. package/docs/reports/unified-9.0.19/raw/legacy-storage-functional-safety.log +6 -0
  130. package/docs/reports/unified-9.0.19/raw/legacy-storage-functional-safety.result.json +14 -0
  131. package/docs/reports/unified-9.0.19/raw/legacy-storage-topology-loader-current.log +2 -0
  132. package/docs/reports/unified-9.0.19/raw/legacy-storage-topology-loader-current.result.json +14 -0
  133. package/docs/reports/unified-9.0.19/raw/legacy-test-loader.cjs +47 -0
  134. package/docs/reports/unified-9.0.19/raw/lint-final.log +16 -0
  135. package/docs/reports/unified-9.0.19/raw/lint-final.result.json +14 -0
  136. package/docs/reports/unified-9.0.19/raw/modules-build.log +5 -0
  137. package/docs/reports/unified-9.0.19/raw/modules-build.result.json +14 -0
  138. package/docs/reports/unified-9.0.19/raw/node22-tests-final.log +10719 -0
  139. package/docs/reports/unified-9.0.19/raw/node22-tests-final.result.json +13 -0
  140. package/docs/reports/unified-9.0.19/raw/node22-typecheck-final.log +7 -0
  141. package/docs/reports/unified-9.0.19/raw/node22-typecheck-final.result.json +14 -0
  142. package/docs/reports/unified-9.0.19/raw/node22-version.log +1 -0
  143. package/docs/reports/unified-9.0.19/raw/node24-tests-final.log +1805 -0
  144. package/docs/reports/unified-9.0.19/raw/node24-tests-final.result.json +13 -0
  145. package/docs/reports/unified-9.0.19/raw/node24-typecheck-final.log +5 -0
  146. package/docs/reports/unified-9.0.19/raw/node24-typecheck-final.result.json +14 -0
  147. package/docs/reports/unified-9.0.19/raw/node24-version.log +1 -0
  148. package/docs/reports/unified-9.0.19/raw/sbom-runtime.log +7 -0
  149. package/docs/reports/unified-9.0.19/raw/sbom-runtime.result.json +14 -0
  150. package/docs/reports/unified-9.0.19/raw/sbom-vendor-check.log +1 -0
  151. package/docs/reports/unified-9.0.19/raw/sbom-vendor-check.result.json +14 -0
  152. package/docs/reports/unified-9.0.19/raw/tariff-price-chain-919.log +11 -0
  153. package/docs/reports/unified-9.0.19/raw/tariff-price-chain-919.result.json +14 -0
  154. package/docs/reports/unified-9.0.19/raw/tariff-price-chain-old-918.log +68 -0
  155. package/docs/reports/unified-9.0.19/raw/tariff-price-chain-old-918.result.json +14 -0
  156. package/docs/reports/unified-9.0.19/raw/ui-docs-check.log +6 -0
  157. package/docs/reports/unified-9.0.19/raw/ui-docs-check.result.json +14 -0
  158. package/docs/reports/unified-9.0.19/raw/ui-runtime-final.log +7 -0
  159. package/docs/reports/unified-9.0.19/raw/ui-runtime-final.result.json +14 -0
  160. package/docs/reports/unified-9.0.19/raw/ui-runtime-sync.log +6 -0
  161. package/docs/reports/unified-9.0.19/raw/ui-runtime-sync.result.json +14 -0
  162. package/docs/reports/unified-9.0.19/raw/ui-sbom-check.log +6 -0
  163. package/docs/reports/unified-9.0.19/raw/ui-sbom-check.result.json +14 -0
  164. package/docs/reports/unified-9.0.19/raw/ui-sbom-final.log +6 -0
  165. package/docs/reports/unified-9.0.19/raw/ui-sbom-final.result.json +14 -0
  166. package/docs/reports/unified-9.0.19/raw/ui-secret-final.log +6 -0
  167. package/docs/reports/unified-9.0.19/raw/ui-secret-final.result.json +14 -0
  168. package/docs/reports/unified-9.0.19/raw/ui-security-final.log +8 -0
  169. package/docs/reports/unified-9.0.19/raw/ui-security-final.result.json +14 -0
  170. package/docs/reports/unified-9.0.20/ANFORDERUNGEN_UND_INBETRIEBNAHME.md +159 -0
  171. package/docs/reports/unified-9.0.20/DEVICE_COMMAND_DELIVERY_REVIEW.md +82 -0
  172. package/docs/reports/unified-9.0.20/DEVICE_LIFECYCLE_REVIEW.md +46 -0
  173. package/docs/reports/unified-9.0.20/DEVICE_PLAN_REVIEW.md +33 -0
  174. package/docs/reports/unified-9.0.20/DEVICE_POWER_CAPABILITY_REVIEW.md +25 -0
  175. package/docs/reports/unified-9.0.20/FARM_CONTROLLER_REVIEW.md +27 -0
  176. package/docs/reports/unified-9.0.20/FARM_DIAGNOSE_UI.md +81 -0
  177. package/docs/reports/unified-9.0.20/FARM_DISPATCH_REVIEW.md +47 -0
  178. package/docs/reports/unified-9.0.20/HISTORY_REVIEW.md +68 -0
  179. package/docs/reports/unified-9.0.20/INFLUXDB2_INSTALLER_UI.md +39 -0
  180. package/docs/reports/unified-9.0.20/INFLUX_CREDENTIAL_NETWORK_REVIEW.md +38 -0
  181. package/docs/reports/unified-9.0.20/INFLUX_DIRECT_UNABHAENGIGE_PRUEFUNG.md +64 -0
  182. package/docs/reports/unified-9.0.20/INFLUX_RUNTIME_INTEGRATION_REVIEW.md +53 -0
  183. package/docs/reports/unified-9.0.20/INFLUX_RUNTIME_UNABHAENGIGE_PRUEFUNG.md +34 -0
  184. package/docs/reports/unified-9.0.20/INFLUX_TRANSPORT_ABSCHLUSSPRUEFUNG.md +55 -0
  185. package/docs/reports/unified-9.0.20/LOGIN_WEBAPP_LOGO.md +29 -0
  186. package/docs/reports/unified-9.0.20/MIGRATION_REVIEW.md +35 -0
  187. package/docs/reports/unified-9.0.20/PRUEFBERICHT.md +54 -0
  188. package/docs/reports/unified-9.0.20/PWA_ANONYMOUS_HTTPS_REVIEW.md +28 -0
  189. package/docs/reports/unified-9.0.20/PWA_ICON_UNABHAENGIGE_PRUEFUNG.md +60 -0
  190. package/docs/reports/unified-9.0.20/SERIAL_LIFECYCLE_REVIEW.md +37 -0
  191. package/docs/reports/unified-9.0.20/SOLAX_READBACK_REVIEW.md +43 -0
  192. package/docs/reports/unified-9.0.20/SOLAX_READBACK_UNABHAENGIGE_PRUEFUNG.md +34 -0
  193. package/docs/reports/unified-9.0.20/STATIC_REVIEW_DE.md +175 -0
  194. package/docs/reports/unified-9.0.20/STORAGE_COMMAND_ACK_REVIEW.md +36 -0
  195. package/docs/reports/unified-9.0.20/TARIFF_REPORT_REVIEW.md +29 -0
  196. package/docs/reports/unified-9.0.20/VISUALISIERUNG.md +64 -0
  197. package/docs/reports/unified-9.0.20/history-setup-navigation-proxy.txt +26 -0
  198. package/docs/reports/unified-9.0.20/history-setup-navigation-ssr.txt +7 -0
  199. package/docs/reports/unified-9.0.20/history-setup-ui-lint.txt +0 -0
  200. package/docs/reports/unified-9.0.20/history-setup-ui-node22.txt +102 -0
  201. package/docs/reports/unified-9.0.20/history-setup-ui-node24.txt +23 -0
  202. package/docs/reports/unified-9.0.20/history-setup-ui-security.txt +0 -0
  203. package/docs/reports/unified-9.0.20/history-setup-ui-typecheck.txt +0 -0
  204. package/docs/reports/unified-9.0.20/login-pwa-branding-hashes.txt +9 -0
  205. package/docs/reports/unified-9.0.20/login-pwa-branding-node22.txt +42 -0
  206. package/docs/reports/unified-9.0.20/login-pwa-branding-node24.txt +13 -0
  207. package/docs/reports/unified-9.0.20/raw/INDEX.json +1913 -0
  208. package/docs/reports/unified-9.0.20/raw/additional-audit/device/baseline-node22.log +16 -0
  209. package/docs/reports/unified-9.0.20/raw/additional-audit/device/baseline-node24.log +14 -0
  210. package/docs/reports/unified-9.0.20/raw/additional-audit/device/lint-after.json +1 -0
  211. package/docs/reports/unified-9.0.20/raw/additional-audit/device/lint-before.json +1 -0
  212. package/docs/reports/unified-9.0.20/raw/additional-audit/device/modbus-stop-backoff.cjs +22 -0
  213. package/docs/reports/unified-9.0.20/raw/additional-audit/device/node22-control-review.log +29 -0
  214. package/docs/reports/unified-9.0.20/raw/additional-audit/device/node22-modbus-final.json +18 -0
  215. package/docs/reports/unified-9.0.20/raw/additional-audit/device/node22-modbus-final.log +325 -0
  216. package/docs/reports/unified-9.0.20/raw/additional-audit/device/node22-modbus-review.log +278 -0
  217. package/docs/reports/unified-9.0.20/raw/additional-audit/device/node24-modbus-final.json +18 -0
  218. package/docs/reports/unified-9.0.20/raw/additional-audit/device/node24-modbus-final.log +58 -0
  219. package/docs/reports/unified-9.0.20/raw/additional-audit/device/node24-modbus-review.log +51 -0
  220. package/docs/reports/unified-9.0.20/raw/additional-audit/history/api-gaps-before.log +64 -0
  221. package/docs/reports/unified-9.0.20/raw/additional-audit/history/api-negative-before.log +46 -0
  222. package/docs/reports/unified-9.0.20/raw/additional-audit/history/chart-gaps-before.log +127 -0
  223. package/docs/reports/unified-9.0.20/raw/additional-audit/history/device-command-subscriptions-after.log +67 -0
  224. package/docs/reports/unified-9.0.20/raw/additional-audit/history/device-command-subscriptions-before.log +61 -0
  225. package/docs/reports/unified-9.0.20/raw/additional-audit/history/device-command-subscriptions-eslint-js.log +0 -0
  226. package/docs/reports/unified-9.0.20/raw/additional-audit/history/device-command-subscriptions-eslint-ts.log +0 -0
  227. package/docs/reports/unified-9.0.20/raw/additional-audit/history/device-command-subscriptions-node22.log +442 -0
  228. package/docs/reports/unified-9.0.20/raw/additional-audit/history/device-command-subscriptions-node24.log +78 -0
  229. package/docs/reports/unified-9.0.20/raw/additional-audit/history/fix.py +73 -0
  230. package/docs/reports/unified-9.0.20/raw/additional-audit/history/history-eslint-final.json +7 -0
  231. package/docs/reports/unified-9.0.20/raw/additional-audit/history/history-final-node22.log +279 -0
  232. package/docs/reports/unified-9.0.20/raw/additional-audit/history/history-final-node24.log +52 -0
  233. package/docs/reports/unified-9.0.20/raw/additional-audit/history/history-followup-node22.log +223 -0
  234. package/docs/reports/unified-9.0.20/raw/additional-audit/history/history-followup-node24.log +43 -0
  235. package/docs/reports/unified-9.0.20/raw/additional-audit/history/history-own-cache.log +17 -0
  236. package/docs/reports/unified-9.0.20/raw/additional-audit/history/negative-pricing-before.log +96 -0
  237. package/docs/reports/unified-9.0.20/raw/additional-audit/history/node22-after.log +66 -0
  238. package/docs/reports/unified-9.0.20/raw/additional-audit/history/node22-repro.log +8 -0
  239. package/docs/reports/unified-9.0.20/raw/additional-audit/history/node24-after.log +17 -0
  240. package/docs/reports/unified-9.0.20/raw/additional-audit/history/node24-repro.log +8 -0
  241. package/docs/reports/unified-9.0.20/raw/additional-audit/history/repro.cjs +39 -0
  242. package/docs/reports/unified-9.0.20/raw/additional-audit/visuals/chromium-probe.log +3 -0
  243. package/docs/reports/unified-9.0.20/raw/additional-audit/visuals/patch-live.py +101 -0
  244. package/docs/reports/unified-9.0.20/raw/additional-audit/visuals/repro-live-display.cjs +26 -0
  245. package/docs/reports/unified-9.0.20/raw/additional-audit/visuals/repro-live-display.log +36 -0
  246. package/docs/reports/unified-9.0.20/raw/audit-full.log +345 -0
  247. package/docs/reports/unified-9.0.20/raw/audit-full.result.json +14 -0
  248. package/docs/reports/unified-9.0.20/raw/audit-runtime.log +23 -0
  249. package/docs/reports/unified-9.0.20/raw/audit-runtime.result.json +15 -0
  250. package/docs/reports/unified-9.0.20/raw/backend-final.log +5 -0
  251. package/docs/reports/unified-9.0.20/raw/backend-final.result.json +14 -0
  252. package/docs/reports/unified-9.0.20/raw/baseline-919-coverage-tests-node22.result.json +20 -0
  253. package/docs/reports/unified-9.0.20/raw/baseline-919-coverage-tests-node22.tap +721 -0
  254. package/docs/reports/unified-9.0.20/raw/baseline-919-coverage-tests-node24.result.json +20 -0
  255. package/docs/reports/unified-9.0.20/raw/baseline-919-coverage-tests-node24.tap +127 -0
  256. package/docs/reports/unified-9.0.20/raw/commissioning-evidence.json +69 -0
  257. package/docs/reports/unified-9.0.20/raw/commissioning-failed-init-drain-919-before.log +14 -0
  258. package/docs/reports/unified-9.0.20/raw/commissioning-final-node22.log +882 -0
  259. package/docs/reports/unified-9.0.20/raw/commissioning-final-node24.log +149 -0
  260. package/docs/reports/unified-9.0.20/raw/commissioning-lint.log +0 -0
  261. package/docs/reports/unified-9.0.20/raw/commissioning-planner-919-before.log +70 -0
  262. package/docs/reports/unified-9.0.20/raw/commissioning-retained-readiness-before.log +34 -0
  263. package/docs/reports/unified-9.0.20/raw/commissioning-runtime-retry-919-before.log +46 -0
  264. package/docs/reports/unified-9.0.20/raw/commissioning-types-node24.log +0 -0
  265. package/docs/reports/unified-9.0.20/raw/device-farm-protocol/DEVICE_FARM_READONLY_REVIEW.md +66 -0
  266. package/docs/reports/unified-9.0.20/raw/device-farm-protocol/run-readback-tests.cjs +13 -0
  267. package/docs/reports/unified-9.0.20/raw/device-farm-protocol/solax-control-chain.test.cjs +58 -0
  268. package/docs/reports/unified-9.0.20/raw/device-lifecycle-baseline-node22.log +16 -0
  269. package/docs/reports/unified-9.0.20/raw/device-lifecycle-baseline-node24.log +14 -0
  270. package/docs/reports/unified-9.0.20/raw/device-lifecycle-evidence.json +55 -0
  271. package/docs/reports/unified-9.0.20/raw/device-lifecycle-lint-after.json +1 -0
  272. package/docs/reports/unified-9.0.20/raw/device-lifecycle-lint-before.json +1 -0
  273. package/docs/reports/unified-9.0.20/raw/device-lifecycle-modbus-stop-backoff.cjs +22 -0
  274. package/docs/reports/unified-9.0.20/raw/device-lifecycle-node22-control-review.log +29 -0
  275. package/docs/reports/unified-9.0.20/raw/device-lifecycle-node22-modbus-final.json +18 -0
  276. package/docs/reports/unified-9.0.20/raw/device-lifecycle-node22-modbus-final.log +325 -0
  277. package/docs/reports/unified-9.0.20/raw/device-lifecycle-node22-modbus-review.log +278 -0
  278. package/docs/reports/unified-9.0.20/raw/device-lifecycle-node24-modbus-final.json +18 -0
  279. package/docs/reports/unified-9.0.20/raw/device-lifecycle-node24-modbus-final.log +58 -0
  280. package/docs/reports/unified-9.0.20/raw/device-lifecycle-node24-modbus-review.log +51 -0
  281. package/docs/reports/unified-9.0.20/raw/devices-hosted-typecheck-node22.log +0 -0
  282. package/docs/reports/unified-9.0.20/raw/devices-hosted-typecheck-node22.result.json +15 -0
  283. package/docs/reports/unified-9.0.20/raw/devices-hosted-typecheck-node24.log +0 -0
  284. package/docs/reports/unified-9.0.20/raw/devices-hosted-typecheck-node24.result.json +15 -0
  285. package/docs/reports/unified-9.0.20/raw/farm-controller/controller-node22.log +110 -0
  286. package/docs/reports/unified-9.0.20/raw/farm-controller/controller-node24.log +24 -0
  287. package/docs/reports/unified-9.0.20/raw/farm-controller/evidence.json +33 -0
  288. package/docs/reports/unified-9.0.20/raw/farm-diagnostics-ui-lint.txt +0 -0
  289. package/docs/reports/unified-9.0.20/raw/farm-diagnostics-ui-node22.txt +113 -0
  290. package/docs/reports/unified-9.0.20/raw/farm-diagnostics-ui-node24.txt +26 -0
  291. package/docs/reports/unified-9.0.20/raw/farm-diagnostics-ui-security.txt +0 -0
  292. package/docs/reports/unified-9.0.20/raw/farm-diagnostics-ui-typecheck.txt +0 -0
  293. package/docs/reports/unified-9.0.20/raw/farm-dispatch/allocator-baseline.jsonl +6 -0
  294. package/docs/reports/unified-9.0.20/raw/farm-dispatch/diagnostics-before.log +138 -0
  295. package/docs/reports/unified-9.0.20/raw/farm-dispatch/diagnostics-main-delta.patch +77 -0
  296. package/docs/reports/unified-9.0.20/raw/farm-dispatch/diagnostics-main-lint.json +7 -0
  297. package/docs/reports/unified-9.0.20/raw/farm-dispatch/diagnostics-node22.log +64 -0
  298. package/docs/reports/unified-9.0.20/raw/farm-dispatch/diagnostics-node22.result.json +14 -0
  299. package/docs/reports/unified-9.0.20/raw/farm-dispatch/diagnostics-node24.log +18 -0
  300. package/docs/reports/unified-9.0.20/raw/farm-dispatch/diagnostics-node24.result.json +14 -0
  301. package/docs/reports/unified-9.0.20/raw/final-ui-independent-review.json +194 -0
  302. package/docs/reports/unified-9.0.20/raw/frontend-build.log +152 -0
  303. package/docs/reports/unified-9.0.20/raw/frontend-build.result.json +14 -0
  304. package/docs/reports/unified-9.0.20/raw/independent-influx/parser-after-node22.json +35 -0
  305. package/docs/reports/unified-9.0.20/raw/independent-influx/parser-after-node22.result.json +17 -0
  306. package/docs/reports/unified-9.0.20/raw/independent-influx/parser-after-node24.json +31 -0
  307. package/docs/reports/unified-9.0.20/raw/independent-influx/parser-after-node24.result.json +17 -0
  308. package/docs/reports/unified-9.0.20/raw/independent-influx/parser-before.json +31 -0
  309. package/docs/reports/unified-9.0.20/raw/independent-influx/parser-reproducer.cjs +9 -0
  310. package/docs/reports/unified-9.0.20/raw/independent-influx/transport-extra-node22.result.json +18 -0
  311. package/docs/reports/unified-9.0.20/raw/independent-influx/transport-extra-node22.tap +34 -0
  312. package/docs/reports/unified-9.0.20/raw/independent-influx/transport-extra-node24.result.json +18 -0
  313. package/docs/reports/unified-9.0.20/raw/independent-influx/transport-extra-node24.tap +11 -0
  314. package/docs/reports/unified-9.0.20/raw/independent-influx/transport-extra.test.cjs +9 -0
  315. package/docs/reports/unified-9.0.20/raw/independent-solax/node22-focused.log +165 -0
  316. package/docs/reports/unified-9.0.20/raw/independent-solax/node24-focused.log +35 -0
  317. package/docs/reports/unified-9.0.20/raw/independent-solax/review-receipt.json +57 -0
  318. package/docs/reports/unified-9.0.20/raw/independent-solax/split-response-after.log +1 -0
  319. package/docs/reports/unified-9.0.20/raw/independent-solax/split-response-before.log +1 -0
  320. package/docs/reports/unified-9.0.20/raw/independent-solax/split-response.cjs +16 -0
  321. package/docs/reports/unified-9.0.20/raw/independent-solax/stop-race-generation-guard.log +1 -0
  322. package/docs/reports/unified-9.0.20/raw/independent-solax/stop-race.cjs +13 -0
  323. package/docs/reports/unified-9.0.20/raw/influx-direct/eslint.log +0 -0
  324. package/docs/reports/unified-9.0.20/raw/influx-direct/node22.log +112 -0
  325. package/docs/reports/unified-9.0.20/raw/influx-direct/node24.log +24 -0
  326. package/docs/reports/unified-9.0.20/raw/influx-direct/typecheck.log +0 -0
  327. package/docs/reports/unified-9.0.20/raw/influx-direct-review/hosted-module-history.test.cjs +85 -0
  328. package/docs/reports/unified-9.0.20/raw/influx-direct-review/independent-node22.json +12 -0
  329. package/docs/reports/unified-9.0.20/raw/influx-direct-review/independent-node22.log +100 -0
  330. package/docs/reports/unified-9.0.20/raw/influx-direct-review/independent-node24.json +12 -0
  331. package/docs/reports/unified-9.0.20/raw/influx-direct-review/independent-node24.log +21 -0
  332. package/docs/reports/unified-9.0.20/raw/influx-direct-review/runtime-after.test.cjs +15 -0
  333. package/docs/reports/unified-9.0.20/raw/influx-direct-review/runtime-loss-before.test.cjs +9 -0
  334. package/docs/reports/unified-9.0.20/raw/influx-direct-review/security-scan.cjs +15 -0
  335. package/docs/reports/unified-9.0.20/raw/influx-direct-review/transport-extra.test.cjs +9 -0
  336. package/docs/reports/unified-9.0.20/raw/influx-independent/legacy-history-node22.log +227 -0
  337. package/docs/reports/unified-9.0.20/raw/influx-independent/legacy-history-node22.result.json +11 -0
  338. package/docs/reports/unified-9.0.20/raw/influx-independent/legacy-history-node24.log +44 -0
  339. package/docs/reports/unified-9.0.20/raw/influx-independent/legacy-history-node24.result.json +11 -0
  340. package/docs/reports/unified-9.0.20/raw/influx-independent/node22.log +112 -0
  341. package/docs/reports/unified-9.0.20/raw/influx-independent/node22.result.json +12 -0
  342. package/docs/reports/unified-9.0.20/raw/influx-independent/node24.log +23 -0
  343. package/docs/reports/unified-9.0.20/raw/influx-independent/node24.result.json +12 -0
  344. package/docs/reports/unified-9.0.20/raw/influx-independent/runtime-after.test.cjs +15 -0
  345. package/docs/reports/unified-9.0.20/raw/influx-independent/transport-extra.test.cjs +9 -0
  346. package/docs/reports/unified-9.0.20/raw/influx-runtime/evidence.json +24 -0
  347. package/docs/reports/unified-9.0.20/raw/influx-runtime/final-node22.log +326 -0
  348. package/docs/reports/unified-9.0.20/raw/influx-runtime/final-node24.log +59 -0
  349. package/docs/reports/unified-9.0.20/raw/influx-runtime/runtime-node22.log +62 -0
  350. package/docs/reports/unified-9.0.20/raw/influx-runtime/runtime-node24.log +16 -0
  351. package/docs/reports/unified-9.0.20/raw/influx-security/security-influx-lint.log +0 -0
  352. package/docs/reports/unified-9.0.20/raw/influx-security/security-influx-lint.result.json +17 -0
  353. package/docs/reports/unified-9.0.20/raw/influx-security/security-influx-node22.log +112 -0
  354. package/docs/reports/unified-9.0.20/raw/influx-security/security-influx-node22.result.json +15 -0
  355. package/docs/reports/unified-9.0.20/raw/influx-security/security-influx-node24.log +106 -0
  356. package/docs/reports/unified-9.0.20/raw/influx-security/security-influx-node24.result.json +15 -0
  357. package/docs/reports/unified-9.0.20/raw/influx-security/security-influx-typecheck.log +0 -0
  358. package/docs/reports/unified-9.0.20/raw/influx-security/security-influx-typecheck.result.json +15 -0
  359. package/docs/reports/unified-9.0.20/raw/influx-security/source-sha256.json +5 -0
  360. package/docs/reports/unified-9.0.20/raw/influx-transport-final/influx-transport-lint-final.log +0 -0
  361. package/docs/reports/unified-9.0.20/raw/influx-transport-final/influx-transport-lint-final.result.json +16 -0
  362. package/docs/reports/unified-9.0.20/raw/influx-transport-final/influx-transport-node22-final.log +124 -0
  363. package/docs/reports/unified-9.0.20/raw/influx-transport-final/influx-transport-node22-final.result.json +14 -0
  364. package/docs/reports/unified-9.0.20/raw/influx-transport-final/influx-transport-node24-final.log +26 -0
  365. package/docs/reports/unified-9.0.20/raw/influx-transport-final/influx-transport-node24-final.result.json +14 -0
  366. package/docs/reports/unified-9.0.20/raw/influx-transport-final/influx-transport-type-node22-final.log +0 -0
  367. package/docs/reports/unified-9.0.20/raw/influx-transport-final/influx-transport-type-node22-final.result.json +15 -0
  368. package/docs/reports/unified-9.0.20/raw/influx-transport-final/influx-transport-type-node24-final.log +0 -0
  369. package/docs/reports/unified-9.0.20/raw/influx-transport-final/influx-transport-type-node24-final.result.json +15 -0
  370. package/docs/reports/unified-9.0.20/raw/influx-ui-independent-review-final.json +285 -0
  371. package/docs/reports/unified-9.0.20/raw/influx-ui-independent-review-intermediate.json +285 -0
  372. package/docs/reports/unified-9.0.20/raw/installer-build.log +26 -0
  373. package/docs/reports/unified-9.0.20/raw/installer-build.result.json +14 -0
  374. package/docs/reports/unified-9.0.20/raw/isolation/INDEX.json +332 -0
  375. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-family-final.log +3 -0
  376. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-family-final.result.json +13 -0
  377. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-family-hosted.log +6 -0
  378. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-family-hosted.result.json +13 -0
  379. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-family-verified.log +1 -0
  380. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-family-verified.result.json +13 -0
  381. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-family.log +11 -0
  382. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-family.result.json +13 -0
  383. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-fenecon-hybrid-final.log +3 -0
  384. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-fenecon-hybrid-final.result.json +13 -0
  385. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-fenecon-hybrid-hosted.log +3 -0
  386. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-fenecon-hybrid-hosted.result.json +13 -0
  387. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-fenecon-hybrid-verified.log +1 -0
  388. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-fenecon-hybrid-verified.result.json +13 -0
  389. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-fenecon-hybrid.log +11 -0
  390. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-fenecon-hybrid.result.json +13 -0
  391. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-final-node22.log +296 -0
  392. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-final-node22.result.json +16 -0
  393. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-final-node24.log +56 -0
  394. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-final-node24.result.json +16 -0
  395. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-node24.log +54 -0
  396. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-node24.result.json +16 -0
  397. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-output-modes.log +1 -0
  398. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-output-modes.result.json +13 -0
  399. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-release-final-node22.log +332 -0
  400. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-release-final-node22.result.json +16 -0
  401. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-release-final-node24.log +62 -0
  402. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-release-final-node24.result.json +16 -0
  403. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-release-node22.log +342 -0
  404. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-release-node22.result.json +16 -0
  405. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-release-node24.log +72 -0
  406. package/docs/reports/unified-9.0.20/raw/isolation/command-ack-release-node24.result.json +16 -0
  407. package/docs/reports/unified-9.0.20/raw/isolation/isolation-node22.log +482 -0
  408. package/docs/reports/unified-9.0.20/raw/isolation/isolation-node22.result.json +19 -0
  409. package/docs/reports/unified-9.0.20/raw/isolation/isolation-node24.log +87 -0
  410. package/docs/reports/unified-9.0.20/raw/isolation/migration-lint.log +0 -0
  411. package/docs/reports/unified-9.0.20/raw/isolation/migration-lint.result.json +16 -0
  412. package/docs/reports/unified-9.0.20/raw/isolation/migration-node22.log +330 -0
  413. package/docs/reports/unified-9.0.20/raw/isolation/migration-node22.result.json +16 -0
  414. package/docs/reports/unified-9.0.20/raw/isolation/migration-node24-before.log +72 -0
  415. package/docs/reports/unified-9.0.20/raw/isolation/migration-node24-before.result.json +16 -0
  416. package/docs/reports/unified-9.0.20/raw/isolation/migration-node24.log +60 -0
  417. package/docs/reports/unified-9.0.20/raw/isolation/migration-node24.result.json +16 -0
  418. package/docs/reports/unified-9.0.20/raw/isolation/repro-migration-start-budget.cjs +49 -0
  419. package/docs/reports/unified-9.0.20/raw/isolation/repro-serial-release.cjs +21 -0
  420. package/docs/reports/unified-9.0.20/raw/isolation/repro-sunspec-discovery.cjs +11 -0
  421. package/docs/reports/unified-9.0.20/raw/isolation/serial-before-repro.log +1 -0
  422. package/docs/reports/unified-9.0.20/raw/isolation/serial-before-repro.result.json +13 -0
  423. package/docs/reports/unified-9.0.20/raw/isolation/serial-gates-node22.log +32 -0
  424. package/docs/reports/unified-9.0.20/raw/isolation/serial-gates-node22.result.json +14 -0
  425. package/docs/reports/unified-9.0.20/raw/isolation/serial-gates-node24.log +11 -0
  426. package/docs/reports/unified-9.0.20/raw/isolation/serial-gates-node24.result.json +14 -0
  427. package/docs/reports/unified-9.0.20/raw/isolation/serial-helper-typecheck-final.log +0 -0
  428. package/docs/reports/unified-9.0.20/raw/isolation/serial-helper-typecheck-final.result.json +28 -0
  429. package/docs/reports/unified-9.0.20/raw/isolation/serial-helper-typecheck.log +2 -0
  430. package/docs/reports/unified-9.0.20/raw/isolation/serial-helper-typecheck.result.json +26 -0
  431. package/docs/reports/unified-9.0.20/raw/isolation/serial-lint.log +0 -0
  432. package/docs/reports/unified-9.0.20/raw/isolation/serial-lint.result.json +18 -0
  433. package/docs/reports/unified-9.0.20/raw/isolation/serial-node22.log +344 -0
  434. package/docs/reports/unified-9.0.20/raw/isolation/serial-node22.result.json +17 -0
  435. package/docs/reports/unified-9.0.20/raw/isolation/serial-node24.log +62 -0
  436. package/docs/reports/unified-9.0.20/raw/isolation/serial-node24.result.json +17 -0
  437. package/docs/reports/unified-9.0.20/raw/isolation/sunspec-review-after.log +3 -0
  438. package/docs/reports/unified-9.0.20/raw/isolation/sunspec-review-after.result.json +13 -0
  439. package/docs/reports/unified-9.0.20/raw/isolation/sunspec-review-before.log +3 -0
  440. package/docs/reports/unified-9.0.20/raw/isolation/sunspec-review-before.result.json +15 -0
  441. package/docs/reports/unified-9.0.20/raw/keygen-source.json +6 -0
  442. package/docs/reports/unified-9.0.20/raw/legacy-mirror-debt/check-919.log +70 -0
  443. package/docs/reports/unified-9.0.20/raw/legacy-mirror-debt/check-920.log +71 -0
  444. package/docs/reports/unified-9.0.20/raw/legacy-mirror-debt/diff.json +82 -0
  445. package/docs/reports/unified-9.0.20/raw/legacy-mirror-debt/receipt.json +48 -0
  446. package/docs/reports/unified-9.0.20/raw/lint-final.log +16 -0
  447. package/docs/reports/unified-9.0.20/raw/lint-final.result.json +14 -0
  448. package/docs/reports/unified-9.0.20/raw/main-individual-review-before-cache-boundary-fix.json +112 -0
  449. package/docs/reports/unified-9.0.20/raw/main-individual-review-before-capability-ack.json +103 -0
  450. package/docs/reports/unified-9.0.20/raw/main-individual-review-before-farm-diagnostics.json +102 -0
  451. package/docs/reports/unified-9.0.20/raw/main-individual-review-final.json +103 -0
  452. package/docs/reports/unified-9.0.20/raw/main-individual-review.json +93 -0
  453. package/docs/reports/unified-9.0.20/raw/modules-build.log +5 -0
  454. package/docs/reports/unified-9.0.20/raw/modules-build.result.json +14 -0
  455. package/docs/reports/unified-9.0.20/raw/node22-tests-final.log +12471 -0
  456. package/docs/reports/unified-9.0.20/raw/node22-tests-final.result.json +13 -0
  457. package/docs/reports/unified-9.0.20/raw/node22-typecheck-final.log +7 -0
  458. package/docs/reports/unified-9.0.20/raw/node22-typecheck-final.result.json +14 -0
  459. package/docs/reports/unified-9.0.20/raw/node22-version.log +1 -0
  460. package/docs/reports/unified-9.0.20/raw/node24-tests-final.log +2093 -0
  461. package/docs/reports/unified-9.0.20/raw/node24-tests-final.result.json +13 -0
  462. package/docs/reports/unified-9.0.20/raw/node24-typecheck-final.log +5 -0
  463. package/docs/reports/unified-9.0.20/raw/node24-typecheck-final.result.json +14 -0
  464. package/docs/reports/unified-9.0.20/raw/node24-version.log +1 -0
  465. package/docs/reports/unified-9.0.20/raw/power-capability/evidence.json +69 -0
  466. package/docs/reports/unified-9.0.20/raw/power-capability/power-capability-existing-regressions-node24.log +94 -0
  467. package/docs/reports/unified-9.0.20/raw/power-capability/power-capability-lint.log +0 -0
  468. package/docs/reports/unified-9.0.20/raw/power-capability/power-capability-node22.log +304 -0
  469. package/docs/reports/unified-9.0.20/raw/power-capability/power-capability-node24.log +56 -0
  470. package/docs/reports/unified-9.0.20/raw/power-capability/power-capability-typecheck.log +0 -0
  471. package/docs/reports/unified-9.0.20/raw/pwa-https/evidence.json +45 -0
  472. package/docs/reports/unified-9.0.20/raw/pwa-https/node22-build.log +21 -0
  473. package/docs/reports/unified-9.0.20/raw/pwa-https/node22-source.log +23 -0
  474. package/docs/reports/unified-9.0.20/raw/pwa-https/node24-build.log +11 -0
  475. package/docs/reports/unified-9.0.20/raw/pwa-https/node24-source.log +11 -0
  476. package/docs/reports/unified-9.0.20/raw/pwa-independent/policy-boundaries.test.cjs +45 -0
  477. package/docs/reports/unified-9.0.20/raw/pwa-independent/policy-receipt.json +71 -0
  478. package/docs/reports/unified-9.0.20/raw/pwa-independent/policy-v22.23.4.tap +34 -0
  479. package/docs/reports/unified-9.0.20/raw/pwa-independent/policy-v24.22.3.tap +11 -0
  480. package/docs/reports/unified-9.0.20/raw/pwa-ui-independent-review-final.json +348 -0
  481. package/docs/reports/unified-9.0.20/raw/repro-failed-init-drain-before.cjs +15 -0
  482. package/docs/reports/unified-9.0.20/raw/repro-profile-replacement-after-unmapped.cjs +15 -0
  483. package/docs/reports/unified-9.0.20/raw/repro-runtime-retry-before.cjs +18 -0
  484. package/docs/reports/unified-9.0.20/raw/sbom-runtime.log +7 -0
  485. package/docs/reports/unified-9.0.20/raw/sbom-runtime.result.json +14 -0
  486. package/docs/reports/unified-9.0.20/raw/sbom-vendor-check.log +1 -0
  487. package/docs/reports/unified-9.0.20/raw/sbom-vendor-check.result.json +14 -0
  488. package/docs/reports/unified-9.0.20/raw/solax-readback-node22.json +30 -0
  489. package/docs/reports/unified-9.0.20/raw/solax-readback-node22.log +542 -0
  490. package/docs/reports/unified-9.0.20/raw/solax-readback-node24.json +30 -0
  491. package/docs/reports/unified-9.0.20/raw/solax-readback-node24.log +97 -0
  492. package/docs/reports/unified-9.0.20/raw/tariff-report-before.log +147 -0
  493. package/docs/reports/unified-9.0.20/raw/tariff-report-evidence.json +48 -0
  494. package/docs/reports/unified-9.0.20/raw/tariff-report-final-node22.log +151 -0
  495. package/docs/reports/unified-9.0.20/raw/tariff-report-final-node24.log +32 -0
  496. package/docs/reports/unified-9.0.20/raw/ui-docs-check.log +6 -0
  497. package/docs/reports/unified-9.0.20/raw/ui-docs-check.result.json +14 -0
  498. package/docs/reports/unified-9.0.20/raw/ui-runtime-final.log +7 -0
  499. package/docs/reports/unified-9.0.20/raw/ui-runtime-final.result.json +14 -0
  500. package/docs/reports/unified-9.0.20/raw/ui-runtime-sync.log +6 -0
  501. package/docs/reports/unified-9.0.20/raw/ui-runtime-sync.result.json +14 -0
  502. package/docs/reports/unified-9.0.20/raw/ui-sbom-check.log +6 -0
  503. package/docs/reports/unified-9.0.20/raw/ui-sbom-check.result.json +14 -0
  504. package/docs/reports/unified-9.0.20/raw/ui-sbom-final.log +6 -0
  505. package/docs/reports/unified-9.0.20/raw/ui-sbom-final.result.json +14 -0
  506. package/docs/reports/unified-9.0.20/raw/ui-secret-final.log +6 -0
  507. package/docs/reports/unified-9.0.20/raw/ui-secret-final.result.json +14 -0
  508. package/docs/reports/unified-9.0.20/raw/ui-security-final.log +8 -0
  509. package/docs/reports/unified-9.0.20/raw/ui-security-final.result.json +14 -0
  510. package/docs/reports/unified-9.0.20/raw/visuals-baseline-919.txt +36 -0
  511. package/docs/reports/unified-9.0.20/raw/visuals-browser-limit.txt +3 -0
  512. package/docs/reports/unified-9.0.20/raw/visuals-lint.txt +0 -0
  513. package/docs/reports/unified-9.0.20/raw/visuals-node22.txt +258 -0
  514. package/docs/reports/unified-9.0.20/raw/visuals-node24.txt +51 -0
  515. package/docs/reports/unified-9.0.20/raw/visuals-security.txt +0 -0
  516. package/docs/reports/unified-9.0.20/raw/visuals-typecheck.txt +0 -0
  517. package/docs/reports/unified-9.0.20/raw/wallet-freshness-after.log +19 -0
  518. package/docs/reports/unified-9.0.20/raw/wallet-freshness-after.result.json +16 -0
  519. package/docs/reports/unified-9.0.20/raw/wallet-freshness-before.log +31 -0
  520. package/docs/reports/unified-9.0.20/raw/wallet-freshness-before.result.json +14 -0
  521. package/docs/reports/unified-9.0.20/raw/wallet-freshness-independent.result.json +13 -0
  522. package/docs/reports/unified-9.0.20/raw/wallet-freshness-independent.tap +10 -0
  523. package/io-package.json +12 -12
  524. package/modules/devices/admin/ems-assignment.d.ts +8 -2
  525. package/modules/devices/admin/ems-assignment.js +192 -30
  526. package/modules/devices/admin/host-bridge.js +36 -11
  527. package/modules/devices/admin/index.html +26 -5
  528. package/modules/devices/admin/index_m.js +87 -3
  529. package/modules/devices/admin/style.css +17 -4
  530. package/modules/devices/checks/emsAssignment.check.js +10 -6
  531. package/modules/devices/contracts.d.ts +1 -1
  532. package/modules/devices/index.js +54 -17
  533. package/modules/devices/lib/device-alias-semantics-v1.json +22 -1
  534. package/modules/devices/lib/deviceAliasFreshness.js +66 -0
  535. package/modules/devices/lib/deviceAliasSemantics.js +13 -3
  536. package/modules/devices/lib/deviceRuntime.js +278 -133
  537. package/modules/devices/lib/drivers/modbus.js +107 -23
  538. package/modules/devices/lib/drivers/modbusAsciiBus.js +47 -31
  539. package/modules/devices/lib/drivers/modbusRtuBus.js +33 -9
  540. package/modules/devices/lib/drivers/modbusSerialLease.js +29 -0
  541. package/modules/devices/lib/drivers/speedwire.js +42 -22
  542. package/modules/devices/lib/modbusReadEvidence.js +29 -0
  543. package/modules/devices/test/deviceAliasFreshness.test.js +154 -0
  544. package/modules/devices/test/emsAssignmentUi.test.js +119 -11
  545. package/modules/devices/test/modbusAuthorizationReads.test.js +112 -0
  546. package/modules/devices/test/modbusConnectLifecycle.test.js +148 -0
  547. package/modules/devices/test/modbusSerialLifecycle.test.js +91 -0
  548. package/modules/devices/test/runtimeLiveness.test.js +1 -1
  549. package/modules/devices/test/serialOperationGate.test.js +3 -3
  550. package/modules/devices/test/solaxReadbackContext.test.js +472 -0
  551. package/modules/devices/test/speedwireLifecycle.test.js +118 -0
  552. package/modules/devices/tsconfig.alias-semantics.json +1 -1
  553. package/modules/devices/tsconfig.hosted.json +1 -1
  554. package/modules/devices/tsconfig.serial-lifecycle.json +18 -0
  555. package/package.json +11 -7
  556. package/release-manifests/unified/build-environment.cdx.json +1483 -7370
  557. package/release-manifests/unified/files.json +758 -185
  558. package/release-manifests/unified/frontend.cdx.json +2688 -5952
  559. package/release-manifests/unified/installer.cdx.json +2053 -821
  560. package/release-manifests/unified/obsolete-admin-assets.json +170 -6
  561. package/release-manifests/unified/runtime.cdx.json +40 -3283
  562. package/release-manifests/unified/validation.json +15 -15
  563. package/tools/eos-release-check.cjs +2 -2
  564. package/tools/eos-release-manifest.cjs +3 -3
  565. package/ui/admin/react/assets/index-BJO3q7oe.js +13 -0
  566. package/ui/admin/react/assets/{index-CuquHlsY.css → index-ofLP_Y7y.css} +1 -1
  567. package/ui/admin/react/index.html +2 -2
  568. package/ui/docs/security/eslint-reviewed-findings.json +26 -26
  569. package/ui/ems/engine.js +54 -7
  570. package/ui/ems/module-manager.js +44 -21
  571. package/ui/ems/modules/core-limits.js +5 -3
  572. package/ui/ems/modules/energy-wallet.js +38 -33
  573. package/ui/ems/modules/storage-control.js +64 -22
  574. package/ui/ems/modules/tarif-vis.js +36 -24
  575. package/ui/ems/modules/tariff-provider.js +28 -6
  576. package/ui/ems/services/tariff-provider-registry.js +11 -8
  577. package/ui/io-package.json +1 -1
  578. package/ui/lib/customer-tariff.js +5 -1
  579. package/ui/lib/influx-config.js +204 -0
  580. package/ui/lib/influx-direct.js +527 -0
  581. package/ui/lib/influx-history-runtime.js +326 -0
  582. package/ui/lib/influx-network-policy.js +112 -0
  583. package/ui/lib/installer-lifecycle.js +134 -1
  584. package/ui/lib/storage-farm-overview.js +115 -0
  585. package/ui/lib/tariff-price.js +115 -0
  586. package/ui/lib/ui-access-policy.js +2 -2
  587. package/ui/main.js +743 -264
  588. package/ui/package.json +18 -6
  589. package/ui/www/app.js +195 -334
  590. package/ui/www/ems-apps.html +4 -1
  591. package/ui/www/ems-apps.js +21 -2
  592. package/ui/www/energy-ledger.html +1 -1
  593. package/ui/www/evcs.html +1 -1
  594. package/ui/www/history.html +1 -1
  595. package/ui/www/history.js +114 -74
  596. package/ui/www/index.html +4 -1
  597. package/ui/www/licenses/smarthome-markdown-components.json +156 -156
  598. package/ui/www/live-display.js +115 -0
  599. package/ui/www/logic.html +1 -1
  600. package/ui/www/login.css +1 -0
  601. package/ui/www/login.html +2 -1
  602. package/ui/www/manifest.webmanifest +2 -2
  603. package/ui/www/power-measurements.js +62 -0
  604. package/ui/www/settings.html +4 -1
  605. package/ui/www/simulation.html +1 -1
  606. package/ui/www/smarthome-config.html +1 -1
  607. package/ui/www/smarthome.html +1 -1
  608. package/ui/www/storagefarm-dispatch.js +287 -0
  609. package/ui/www/storagefarm-summary.css +32 -0
  610. package/ui/www/storagefarm-summary.js +136 -0
  611. package/ui/www/storagefarm.html +31 -2
  612. package/ui/www/storagefarm.js +14 -44
  613. package/ui/www/tariff-display.js +161 -0
  614. package/ui/www/tariff-report.js +43 -25
  615. package/ui/admin/react/assets/index-Bq5IupDw.js +0 -13
@@ -0,0 +1 @@
1
+ [{"filePath":"/workspace/scratch/741f792566ea/source-919/iobroker.eos-admin/modules/devices/lib/drivers/modbus.js","messages":[{"ruleId":"no-unused-vars","severity":2,"message":"'isModbusIllegalValue' is defined but never used.","line":103,"column":10,"nodeType":"Identifier","messageId":"unusedVar","endLine":103,"endColumn":30,"suggestions":[{"messageId":"removeVar","data":{"varName":"isModbusIllegalValue"},"fix":{"range":[3848,4192],"text":""},"desc":"Remove unused variable 'isModbusIllegalValue'."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":973,"column":47,"nodeType":"BlockStatement","messageId":"unexpected","endLine":973,"endColumn":49,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[43780,43780],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":987,"column":98,"nodeType":"BlockStatement","messageId":"unexpected","endLine":987,"endColumn":100,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[44269,44269],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":988,"column":75,"nodeType":"BlockStatement","messageId":"unexpected","endLine":988,"endColumn":77,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[44346,44346],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":989,"column":83,"nodeType":"BlockStatement","messageId":"unexpected","endLine":989,"endColumn":85,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[44431,44431],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":991,"column":17,"nodeType":"BlockStatement","messageId":"unexpected","endLine":991,"endColumn":19,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[44458,44458],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1007,"column":21,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1007,"endColumn":23,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[45129,45129],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1017,"column":80,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1017,"endColumn":82,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[45563,45563],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1020,"column":88,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1020,"endColumn":90,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[45688,45688],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-unused-vars","severity":2,"message":"'err' is defined but never used. Allowed unused args must match /^_/u.","line":1030,"column":21,"nodeType":"Identifier","messageId":"unusedVar","endLine":1030,"endColumn":24,"suggestions":[{"messageId":"removeVar","data":{"varName":"err"},"fix":{"range":[45842,45845],"text":""},"desc":"Remove unused variable 'err'."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1037,"column":65,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1037,"endColumn":67,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[46199,46199],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1063,"column":58,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1063,"endColumn":60,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[47414,47414],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1131,"column":21,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1131,"endColumn":23,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[49969,49969],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1162,"column":21,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1162,"endColumn":23,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[51170,51170],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1276,"column":79,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1276,"endColumn":81,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[54789,54789],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1304,"column":17,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1304,"endColumn":19,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[55859,55859],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1430,"column":19,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1430,"endColumn":21,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[61587,61587],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1663,"column":17,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1663,"endColumn":19,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[72491,72491],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1694,"column":17,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1694,"endColumn":19,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[74215,74215],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1773,"column":21,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1773,"endColumn":23,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[78124,78124],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1788,"column":25,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1788,"endColumn":27,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[79191,79191],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1790,"column":148,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1790,"endColumn":150,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[79360,79360],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1912,"column":23,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1912,"endColumn":25,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[84860,84860],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":1926,"column":19,"nodeType":"BlockStatement","messageId":"unexpected","endLine":1926,"endColumn":21,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[85502,85502],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-unused-vars","severity":2,"message":"'g' is defined but never used. Allowed unused args must match /^_/u.","line":1990,"column":37,"nodeType":"Identifier","messageId":"unusedVar","endLine":1990,"endColumn":38,"suggestions":[{"messageId":"removeVar","data":{"varName":"g"},"fix":{"range":[88650,88651],"text":""},"desc":"Remove unused variable 'g'."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":2260,"column":17,"nodeType":"BlockStatement","messageId":"unexpected","endLine":2260,"endColumn":19,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[99557,99557],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":2326,"column":69,"nodeType":"BlockStatement","messageId":"unexpected","endLine":2326,"endColumn":71,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[102176,102176],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":2396,"column":68,"nodeType":"BlockStatement","messageId":"unexpected","endLine":2396,"endColumn":70,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[105379,105379],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":2465,"column":17,"nodeType":"BlockStatement","messageId":"unexpected","endLine":2465,"endColumn":19,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[107445,107445],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":2660,"column":23,"nodeType":"BlockStatement","messageId":"unexpected","endLine":2660,"endColumn":25,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[115843,115843],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":2883,"column":50,"nodeType":"BlockStatement","messageId":"unexpected","endLine":2883,"endColumn":52,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[124879,124879],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":2890,"column":57,"nodeType":"BlockStatement","messageId":"unexpected","endLine":2890,"endColumn":59,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[125329,125329],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":2904,"column":19,"nodeType":"BlockStatement","messageId":"unexpected","endLine":2904,"endColumn":21,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[126047,126047],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":2928,"column":52,"nodeType":"BlockStatement","messageId":"unexpected","endLine":2928,"endColumn":54,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[127316,127316],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3259,"column":176,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3259,"endColumn":178,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[140173,140173],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3400,"column":134,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3400,"endColumn":136,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[147434,147434],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3417,"column":200,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3417,"endColumn":202,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[148336,148336],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3449,"column":214,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3449,"endColumn":216,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[150032,150032],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3453,"column":197,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3453,"endColumn":199,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[150380,150380],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3474,"column":194,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3474,"endColumn":196,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[151459,151459],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3500,"column":227,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3500,"endColumn":229,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[152912,152912],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3504,"column":191,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3504,"endColumn":193,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[153254,153254],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3529,"column":177,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3529,"endColumn":179,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[154402,154402],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3689,"column":19,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3689,"endColumn":21,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[163061,163061],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3889,"column":21,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3889,"endColumn":23,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[173212,173212],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3917,"column":58,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3917,"endColumn":60,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[174241,174241],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3918,"column":66,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3918,"endColumn":68,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[174309,174309],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3924,"column":89,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3924,"endColumn":91,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[174804,174804],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3925,"column":70,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3925,"endColumn":72,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[174876,174876],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]},{"ruleId":"no-empty","severity":2,"message":"Empty block statement.","line":3949,"column":65,"nodeType":"BlockStatement","messageId":"unexpected","endLine":3949,"endColumn":67,"suggestions":[{"messageId":"suggestComment","data":{"type":"block"},"fix":{"range":[175814,175814],"text":" /* empty */ "},"desc":"Add comment inside empty block statement."}]}],"suppressedMessages":[],"errorCount":50,"fatalErrorCount":0,"warningCount":0,"fixableErrorCount":0,"fixableWarningCount":0,"source":"'use strict';\n\n/*\n Modbus driver (RTU + ASCII + TCP) with support for:\n - FC1/FC3/FC4 reads\n - FC5/FC6/FC16 writes\n - per-datapoint read/write mapping (source.read / source.write)\n - wordOrder (be/le) and byteOrder (be/le)\n - optional transforms: scaleFactor (10^n), invert, invertIfSetting, keepPositive, keepNegativeAndInvert\n*/\n\nconst ModbusRTU = require('modbus-serial');\nconst { acquireBus, releaseBus } = require('./modbusRtuBus');\nconst { acquireBus: acquireAsciiBus, releaseBus: releaseAsciiBus } = require('./modbusAsciiBus');\nconst { applyScale, removeScale, bigIntToNumberOrString } = require('../utils');\nconst { decodeAsciiLswFirst, encodeAsciiLswFirst, decodeHexLswFirst, decodeIpv4U16 } = require('../weidmuellerCodec');\n\n// Generic async sleep helper (used for Modbus pacing/backoff)\nconst sleep = (ms) => new Promise(resolve => setTimeout(resolve, ms));\n\n\nfunction _errCode(err) {\n try { return (err && err.code) ? String(err.code) : ''; } catch (_) { return ''; }\n}\n\nfunction _errMsg(err) {\n try { return (err && err.message) ? String(err.message) : String(err); } catch (_) { return ''; }\n}\n\n// Hosted authorization and lifecycle boundaries are not device/register errors.\n// They must abort the whole snapshot without marking valid optional registers\n// unsupported for the subsequent permitted poll.\nfunction isReadOperationBoundaryError(err) {\n return ['EOS_DEVICES_NOT_AUTHORIZED', 'EOS_DEVICES_STOPPED', 'EOS_MODULE_STOPPED', 'EOS_OWNERSHIP_REQUIRED']\n .includes(_errCode(err) || _errMsg(err));\n}\n\nfunction isTransportError(err) {\n const code = _errCode(err);\n const msg = _errMsg(err);\n const lower = msg.toLowerCase();\n\n if ([\n 'ECONNREFUSED',\n 'ECONNRESET',\n 'EPIPE',\n 'ETIMEDOUT',\n 'EHOSTUNREACH',\n 'ENETUNREACH',\n 'ENOTFOUND',\n 'ERR_SOCKET_CLOSED',\n 'E_MODBUS_OPERATION_TIMEOUT',\n 'E_MODBUS_CONNECT_TIMEOUT',\n 'E_MODBUS_BUSY_STALE',\n ].includes(code)) return true;\n\n // modbus-serial commonly uses this message when the underlying socket/serial port is closed\n if (lower.includes('port not open')) return true;\n\n // modbus-serial sometimes reports timeouts without setting an error code.\n // In that case we still want to treat it like a transport problem and force a reconnect.\n if (lower.includes('timed out') || lower.includes('timeout')) return true;\n if (lower.includes('hard-timeout') || lower.includes('hard timeout')) return true;\n\n // generic socket messages\n if (lower.includes('not connected')) return true;\n if (lower.includes('socket') && (lower.includes('hang up') || lower.includes('closed') || lower.includes('ended'))) return true;\n\n return false;\n}\n\n\nfunction _modbusExceptionCode(err) {\n try {\n const raw = err && (err.modbusCode ?? err.exceptionCode ?? err.exception ?? err.modbusExceptionCode ?? err.responseCode);\n const n = Number(raw);\n return Number.isFinite(n) ? n : undefined;\n } catch (_) {\n return undefined;\n }\n}\n\nfunction isModbusIllegalAddressOrValue(err) {\n const msg = _errMsg(err).toLowerCase();\n const code = _modbusExceptionCode(err);\n if (code === 2 || code === 3) return true;\n if (msg.includes('modbus exception 2') || msg.includes('exception 2:')) return true;\n if (msg.includes('modbus exception 3') || msg.includes('exception 3:')) return true;\n if (msg.includes('illegal data address') || msg.includes('illegal address')) return true;\n if (msg.includes('illegal data value') || msg.includes('illegal value')) return true;\n return false;\n}\n\nfunction isModbusIllegalAddress(err) {\n const msg = _errMsg(err).toLowerCase();\n const code = _modbusExceptionCode(err);\n if (code === 2) return true;\n if (msg.includes('modbus exception 2') || msg.includes('exception 2:')) return true;\n if (msg.includes('illegal data address') || msg.includes('illegal address')) return true;\n return false;\n}\n\nfunction isModbusIllegalValue(err) {\n const msg = _errMsg(err).toLowerCase();\n const code = _modbusExceptionCode(err);\n if (code === 3) return true;\n if (msg.includes('modbus exception 3') || msg.includes('exception 3:')) return true;\n if (msg.includes('illegal data value') || msg.includes('illegal value')) return true;\n return false;\n}\n\nfunction isModbusProtocolException(err) {\n if (isTransportError(err)) return false;\n const msg = _errMsg(err).toLowerCase();\n const code = _modbusExceptionCode(err);\n if (Number.isFinite(code) && code >= 1 && code <= 255) return true;\n if (msg.includes('modbus exception')) return true;\n if (msg.includes('slave device failure')) return true;\n if (msg.includes('illegal function')) return true;\n if (msg.includes('device busy')) return true;\n return false;\n}\n\nfunction normalizeAddressFallbackOffsets(src) {\n if (src && (src.disableAddressFallbackOffsets === true || src.disableAddressFallbacks === true || src.noAddressFallback === true || src.noFallbackAddressOffsets === true)) return [];\n const raw = src && (src.fallbackAddressOffsets ?? src.alternateAddressOffsets ?? src.retryAddressOffsets ?? src.addressFallbackOffsets);\n const arr = Array.isArray(raw) ? raw : (raw === undefined || raw === null ? [] : [raw]);\n const out = [];\n for (const v of arr) {\n const n = Number(v);\n if (!Number.isFinite(n) || !Number.isInteger(n) || n === 0) continue;\n // Conservative: this is for documented off-by-one vendor variants only, not arbitrary scanning.\n if (Math.abs(n) > 2) continue;\n if (!out.includes(n)) out.push(n);\n }\n return out;\n}\n\n\nfunction normalizeWordOrder(v) {\n const s = (v ?? '').toString().toLowerCase();\n if (s === 'le' || s === 'little' || s === 'little_endian' || s === 'lswmsw' || s === 'lsw_msw') return 'le';\n return 'be';\n}\n\nfunction normalizeByteOrder(v) {\n const s = (v ?? '').toString().toLowerCase();\n if (s === 'le' || s === 'little' || s === 'little_endian') return 'le';\n return 'be';\n}\n\nfunction swapBytesInWords(buf) {\n // swap bytes inside each 16-bit register word\n for (let i = 0; i + 1 < buf.length; i += 2) {\n const a = buf[i];\n buf[i] = buf[i + 1];\n buf[i + 1] = a;\n }\n}\n\nfunction regsToBuffer(regs, wordOrder, byteOrder) {\n const wo = normalizeWordOrder(wordOrder);\n const bo = normalizeByteOrder(byteOrder);\n\n const arr = Array.isArray(regs) ? regs.slice() : [];\n if (wo === 'le') arr.reverse();\n\n const buf = Buffer.alloc(arr.length * 2);\n for (let i = 0; i < arr.length; i++) {\n buf.writeUInt16BE(arr[i] & 0xFFFF, i * 2);\n }\n\n if (bo === 'le') swapBytesInWords(buf);\n return buf;\n}\n\nfunction bufferToRegs(buf, wordOrder, byteOrder) {\n const wo = normalizeWordOrder(wordOrder);\n const bo = normalizeByteOrder(byteOrder);\n\n const tmp = Buffer.from(buf); // copy\n if (bo === 'le') swapBytesInWords(tmp);\n\n const regs = [];\n for (let i = 0; i < tmp.length; i += 2) {\n regs.push(tmp.readUInt16BE(i));\n }\n\n if (wo === 'le') regs.reverse();\n return regs;\n}\n\n\nfunction decodeBcdHhmmss(buf) {\n // Mennekes and a few other Modbus devices expose time-of-day as\n // big-endian packed BCD with left-zero padding across two registers.\n // Example bytes: 00 12 34 56 -> \"12:34:56\".\n if (!buf || !buf.length) return '';\n let digits = '';\n for (const b of buf) {\n const hi = (b >>> 4) & 0x0F;\n const lo = b & 0x0F;\n if (hi > 9 || lo > 9) return '';\n digits += String(hi) + String(lo);\n }\n if (digits.length < 6) digits = digits.padStart(6, '0');\n digits = digits.slice(-6);\n const hh = digits.slice(0, 2);\n const mm = digits.slice(2, 4);\n const ss = digits.slice(4, 6);\n return `${hh}:${mm}:${ss}`;\n}\n\nfunction bufferToValue(buf, dataType) {\n const t = (dataType || 'uint16').toString().toLowerCase();\n\n switch (t) {\n case 'bool':\n case 'boolean': {\n // Some devices store booleans in registers (uint16 0/1). In that case the buffer length is 2.\n if (buf.length >= 2) return buf.readUInt16BE(0) !== 0;\n return buf.readUInt8(0) !== 0;\n }\n\n case 'string':\n case 'ascii': {\n const s = buf.toString('ascii');\n const nul = s.indexOf('\\0');\n return (nul >= 0 ? s.substring(0, nul) : s).trim();\n }\n\n case 'ascii_lsw_first':\n case 'string_lsw_first':\n case 'weidmueller_ascii':\n return decodeAsciiLswFirst(buf);\n\n case 'hex_lsw_first':\n case 'weidmueller_hex':\n return decodeHexLswFirst(buf);\n\n case 'ipv4_u16':\n case 'weidmueller_ipv4':\n return decodeIpv4U16(buf);\n\n case 'bcd_hhmmss':\n case 'bcdhhmmss':\n case 'hhmmss_bcd':\n case 'hhmmss':\n return decodeBcdHhmmss(buf);\n\n case 'int16':\n return buf.readInt16BE(0);\n case 'uint16':\n return buf.readUInt16BE(0);\n case 'int32':\n return buf.readInt32BE(0);\n case 'uint32':\n return buf.readUInt32BE(0);\n case 'float32':\n return buf.readFloatBE(0);\n case 'int64':\n return buf.readBigInt64BE(0);\n case 'uint64':\n return buf.readBigUInt64BE(0);\n case 'float64':\n return buf.readDoubleBE(0);\n default:\n return buf.readUInt16BE(0);\n }\n}\n\nfunction valueToBuffer(value, dataType, byteLength) {\n const t = (dataType || 'uint16').toString().toLowerCase();\n const bl = Number(byteLength || 2);\n const buf = Buffer.alloc(bl);\n\n if (t === 'bool' || t === 'boolean') {\n // If this is a register (2 bytes), write a uint16 0/1. For coils (1 byte) write 0/1.\n if (bl >= 2) {\n buf.writeUInt16BE(value ? 1 : 0, 0);\n } else {\n buf.writeUInt8(value ? 1 : 0, 0);\n }\n return buf;\n }\n\n if (t === 'string' || t === 'ascii') {\n const s = (value === null || value === undefined) ? '' : String(value);\n buf.fill(0);\n buf.write(s, 0, Math.min(buf.length, Buffer.byteLength(s, 'ascii')), 'ascii');\n return buf;\n }\n\n if (t === 'ascii_lsw_first' || t === 'string_lsw_first' || t === 'weidmueller_ascii') {\n return encodeAsciiLswFirst(value, bl);\n }\n\n // Use BigInt for 64-bit if user provides a string\n const asBigInt = (v) => {\n if (typeof v === 'bigint') return v;\n if (typeof v === 'number') return BigInt(Math.trunc(v));\n if (typeof v === 'string') {\n try { return BigInt(v); } catch (e) { return BigInt(0); }\n }\n return BigInt(0);\n };\n\n switch (t) {\n case 'int16':\n buf.writeInt16BE(Math.round(Number(value)), 0);\n break;\n case 'uint16':\n buf.writeUInt16BE(Math.round(Number(value)), 0);\n break;\n case 'int32':\n buf.writeInt32BE(Math.round(Number(value)), 0);\n break;\n case 'uint32':\n buf.writeUInt32BE(Math.round(Number(value)), 0);\n break;\n case 'float32':\n buf.writeFloatBE(Number(value), 0);\n break;\n case 'int64':\n buf.writeBigInt64BE(asBigInt(value), 0);\n break;\n case 'uint64':\n buf.writeBigUInt64BE(asBigInt(value), 0);\n break;\n case 'float64':\n buf.writeDoubleBE(Number(value), 0);\n break;\n default:\n buf.writeUInt16BE(Number(value), 0);\n break;\n }\n return buf;\n}\n\n\nfunction isNumericModbusDataType(dataType) {\n const t = (dataType || 'uint16').toString().toLowerCase();\n return !['string', 'ascii', 'bool', 'boolean', 'bcd_hhmmss', 'bcdhhmmss', 'hhmmss_bcd', 'hhmmss'].includes(t);\n}\n\nfunction dataTypeWordLength(dataType) {\n const t = (dataType || 'uint16').toString().toLowerCase();\n if (t === 'bool' || t === 'boolean' || t === 'int16' || t === 'uint16') return 1;\n if (t === 'int32' || t === 'uint32' || t === 'float32') return 2;\n if (t === 'int64' || t === 'uint64' || t === 'float64') return 4;\n return 1;\n}\n\nfunction parseNumericMaybeHex(x) {\n if (x === null || x === undefined) return undefined;\n if (typeof x === 'number') return Number.isFinite(x) ? x : undefined;\n if (typeof x === 'boolean') return x ? 1 : 0;\n if (typeof x === 'string') {\n const s = x.trim().toLowerCase().replace(',', '.');\n if (!s) return undefined;\n if (s.startsWith('0x')) {\n const n = parseInt(s, 16);\n return Number.isFinite(n) ? n : undefined;\n }\n const direct = Number(s);\n if (Number.isFinite(direct)) return direct;\n // Accept UI/front-end strings such as \"6 a\", \"3 phases\" or \"4.2 kw\".\n const m = s.match(/[-+]?\\d+(?:\\.\\d+)?/);\n if (!m) return undefined;\n const n = Number(m[0]);\n return Number.isFinite(n) ? n : undefined;\n }\n return undefined;\n}\n\nfunction normalizeAllowedValues(values) {\n if (!Array.isArray(values)) return [];\n const out = [];\n for (const v of values) {\n const n = parseNumericMaybeHex(v);\n if (n !== undefined && !out.includes(n)) out.push(n);\n }\n return out;\n}\n\nfunction normalizeAllowedRanges(values) {\n if (!Array.isArray(values)) return [];\n const out = [];\n for (const r of values) {\n let min;\n let max;\n if (Array.isArray(r)) {\n min = parseNumericMaybeHex(r[0]);\n max = parseNumericMaybeHex(r[1]);\n } else if (r && typeof r === 'object') {\n min = parseNumericMaybeHex(r.min ?? r.from ?? r.start ?? r[0]);\n max = parseNumericMaybeHex(r.max ?? r.to ?? r.end ?? r[1]);\n }\n if (min === undefined || max === undefined) continue;\n if (max < min) { const tmp = min; min = max; max = tmp; }\n out.push({ min, max });\n }\n return out;\n}\n\nfunction applyWriteValueConstraints(raw, src, dpId) {\n const dt = (src && src.dataType ? src.dataType : 'uint16').toString().toLowerCase();\n if (src && src.valueMap && typeof src.valueMap === 'object') {\n const key = String(raw);\n if (Object.prototype.hasOwnProperty.call(src.valueMap, key)) {\n raw = src.valueMap[key];\n }\n }\n\n if (!isNumericModbusDataType(dt)) return raw;\n\n const n = parseNumericMaybeHex(raw);\n if (src && src.finite === true && n === undefined) {\n throw new Error(`Invalid non-numeric Modbus write value for ${dpId || 'datapoint'}: ${raw}`);\n }\n\n let v = (n !== undefined) ? n : raw;\n if (typeof v !== 'number') return v;\n if (!Number.isFinite(v)) {\n throw new Error(`Invalid non-finite Modbus write value for ${dpId || 'datapoint'}: ${raw}`);\n }\n\n const allowed = normalizeAllowedValues(src && (src.allowedValues || src.enumValues || src.validValues));\n const allowedRanges = normalizeAllowedRanges(src && (src.allowedRanges || src.validRanges || src.writeRanges));\n if (allowed.length || allowedRanges.length) {\n const inAllowedValue = allowed.includes(v);\n const inAllowedRange = allowedRanges.some(r => v >= r.min && v <= r.max);\n if (!inAllowedValue && !inAllowedRange) {\n const parts = [];\n if (allowed.length) parts.push(allowed.join(', '));\n if (allowedRanges.length) parts.push(allowedRanges.map(r => `${r.min}..${r.max}`).join(', '));\n throw new Error(`Invalid Modbus write value for ${dpId || 'datapoint'}: ${v}. Allowed values/ranges: ${parts.join('; ')}`);\n }\n }\n\n const nonZeroMin = parseNumericMaybeHex(src && (src.zeroOrMinValue ?? src.nonZeroMinValue ?? src.positiveMinValue ?? src.minPositiveValue));\n if (nonZeroMin !== undefined && v > 0 && v < nonZeroMin) {\n v = nonZeroMin;\n }\n\n const min = parseNumericMaybeHex(src && (src.minValue ?? src.min ?? src.writeMin));\n const max = parseNumericMaybeHex(src && (src.maxValue ?? src.max ?? src.writeMax));\n if (min !== undefined && v < min) {\n throw new Error(`Invalid Modbus write value for ${dpId || 'datapoint'}: ${v} is below minimum ${min}`);\n }\n if (max !== undefined && v > max) {\n throw new Error(`Invalid Modbus write value for ${dpId || 'datapoint'}: ${v} is above maximum ${max}`);\n }\n\n if (src && (src.round === true || src.integer === true || src.int === true)) v = Math.round(v);\n return v;\n}\n\nfunction mergeModbusSource(root, override) {\n if (!root || root.kind !== 'modbus') return null;\n const merged = Object.assign({}, root, override || {});\n merged.kind = 'modbus';\n return merged;\n}\n\nfunction getReadSource(dp) {\n const src = dp?.source;\n if (!src || src.kind !== 'modbus') return null;\n if (src.poll === false || src.readPoll === false || src.disablePoll === true || src.disabled === true) return null;\n const rs = src.read || src;\n if (!rs || rs.fc == null) return null;\n if (rs.poll === false || rs.readPoll === false || rs.disablePoll === true || rs.disabled === true) return null;\n return mergeModbusSource(src, rs);\n}\n\nfunction getWriteSource(dp) {\n const src = dp?.source;\n if (!src || src.kind !== 'modbus') return null;\n const ws = src.write || src;\n if (!ws || ws.fc == null) return null;\n return mergeModbusSource(src, ws);\n}\n\nfunction buildGroups(items, maxRegs, options) {\n const max = Number(maxRegs || 120);\n // Some devices reject requests that include unmapped/reserved registers even\n // when the requested span is small. For those templates, set\n // driverHints.modbus.strictContiguousReads=true to split reads at gaps.\n const allowGaps = !(options && options.allowGaps === false);\n // Some devices expose optional registers inside otherwise contiguous ranges. If one\n // optional register rejects the request, a combined group can suppress important\n // neighbours. isolateItems keeps each datapoint in its own Modbus request while\n // still reading multi-register values (FLOAT32/FLOAT64/STRING) atomically.\n const isolateItems = !!(options && options.isolateItems === true);\n\n const normalizeReadRequestGroup = (src) => {\n if (!src || typeof src !== 'object') return null;\n const raw = src.readRequestGroup ?? src.readGroup ?? src.requestGroup;\n if (raw === undefined || raw === null || raw === '') return null;\n return String(raw);\n };\n\n const dps = (items || [])\n .map(item => {\n const addr = Number(item.addr);\n const len = Number(item.len || 1);\n return {\n ...item,\n addr,\n len,\n end: addr + len - 1,\n readRequestGroup: normalizeReadRequestGroup(item && item.src),\n };\n })\n .sort((a, b) => a.addr - b.addr);\n\n if (isolateItems) {\n return dps.map(item => ({\n start: item.addr,\n end: item.end,\n items: [item],\n readRequestGroup: item.readRequestGroup,\n }));\n }\n\n const groups = [];\n let g = null;\n\n for (const item of dps) {\n if (!g) {\n g = {\n start: item.addr,\n end: item.end,\n items: [item],\n readRequestGroup: item.readRequestGroup,\n };\n continue;\n }\n\n const newEnd = Math.max(g.end, item.end);\n const span = newEnd - g.start + 1;\n const contiguous = item.addr <= (g.end + 1);\n // Explicit request groups are protocol boundaries. ABL EVCC2/3, for example,\n // requires 0x0001 as an exact R2 request and 0x0003 as a separate R1 request;\n // merging the contiguous addresses into 0x0001/3 makes the controller stay silent.\n const sameExplicitRequestGroup = g.readRequestGroup === item.readRequestGroup;\n\n if (span <= max && (allowGaps || contiguous) && sameExplicitRequestGroup) {\n g.end = newEnd;\n g.items.push(item);\n } else {\n groups.push(g);\n g = {\n start: item.addr,\n end: item.end,\n items: [item],\n readRequestGroup: item.readRequestGroup,\n };\n }\n }\n\n if (g) groups.push(g);\n return groups;\n}\n\nclass ModbusDriver {\n constructor(adapter, deviceConfig, template, globalConfig) {\n this.adapter = adapter;\n this.device = deviceConfig;\n this.template = template;\n this.global = globalConfig || {};\n\n this.client = null; // TCP client\n this.rtuBus = null;\n this.rtuBusKey = null;\n this.asciiBus = null;\n this.asciiBusKey = null;\n\n if (deviceConfig.protocol === 'modbusTcp') {\n this.client = new ModbusRTU();\n }\n this.connected = false;\n this.connecting = false;\n this._busy = false;\n\n // Cache for dynamic scale factors (e.g. SunSpec *_SF registers)\n this._sfCache = new Map();\n this._sfWarnedUntil = new Map(); // throttle warnings for broken scale factors (e.g. wrong endian)\n\n const c = deviceConfig.connection || {};\n\n // Optional driver hints from templates (best-effort)\n const hints = (template && template.driverHints && template.driverHints.modbus) ? template.driverHints.modbus : {};\n this._modbusHints = hints;\n\n // DEPower V10.03 AC/DC charge-point control is not a collection of independent\n // writable registers. Field testing showed that the station can continuously\n // report 0 for the universal Charge mode / station power registers while the\n // connector-specific command and power registers still exist. NexoWatt therefore\n // treats ctrl.run + ctrl.powerLimitW as the authoritative command interface and\n // re-applies the documented prerequisites immediately before a start/power command.\n // The raw RW datapoints remain real device readbacks and are intentionally allowed\n // to return to the value reported by the charger.\n const depowerHints = (template && template.driverHints && template.driverHints.oemModbusV1003 && typeof template.driverHints.oemModbusV1003 === 'object')\n ? template.driverHints.oemModbusV1003\n : null;\n this._depowerV1003 = depowerHints;\n this._depowerControlQueue = Promise.resolve();\n for (const key of ['depowerSessionEnergyWhPerTick', 'depowerTotalEnergyWhPerTick']) {\n const configured = this.device?.connection?.[key];\n if (depowerHints && configured !== undefined && configured !== null && configured !== '' &&\n ![0.1, 1, 10, 100, 1000].includes(Number(configured))) {\n throw new Error(`Invalid ${key}: expected 0.1, 1, 10, 100 or 1000 Wh per register tick`);\n }\n }\n this._depowerDesiredPowerW = undefined;\n this._depowerDesiredRun = undefined;\n this._depowerLastPrepareRearmAt = 0;\n\n // Vendor/profile detection must not depend on user connection settings. Alfen ACE\n // templates store real Modbus protocol addresses (document register - 1) and use\n // fixed Unit-IDs per socket/SCN. Any stale UI/global address offset would move\n // 32-bit control values into the wrong register pair (e.g. 1209 -> 1210), so we\n // hard-disable address offsets/fallbacks for every Alfen profile here as well as\n // in the templates.\n const tplIdLowerForFallback = String((template && template.id) || deviceConfig.templateId || deviceConfig.template || '').toLowerCase();\n const mfrLowerForFallback = String((template && template.manufacturer) || deviceConfig.manufacturer || deviceConfig.vendor || '').toLowerCase();\n const profileLowerForFallback = `${tplIdLowerForFallback} ${mfrLowerForFallback} ${String(deviceConfig.name || '').toLowerCase()}`;\n this._isAlfenProfile = mfrLowerForFallback === 'alfen' || profileLowerForFallback.includes('alfen');\n\n // Alfen ACE exposes the live meter registers even when the EMS socket-control\n // registers are not enabled in ACE Service Installer. If we try to WRITE the\n // Max Current register while that block is not exposed, some chargers answer\n // with Modbus exception 2/3 and may temporarily refuse new TCP sessions.\n // Therefore Alfen control writes are preflight-probed and temporarily disabled\n // per session as soon as the charger tells us the block is not available.\n const alfenTopHints = (template && template.alfen && typeof template.alfen === 'object') ? template.alfen : {};\n const alfenModbusHints = (hints && typeof hints.alfen === 'object' && hints.alfen) ? hints.alfen : {};\n const alfenHints = Object.assign({}, alfenTopHints, alfenModbusHints);\n this._alfenHints = alfenHints;\n this._alfenProbeControlBeforeWrite = this._isAlfenProfile && alfenHints.probeControlBeforeWrite !== false;\n this._alfenControlUnsupportedUntil = 0;\n this._alfenScnUnsupportedUntil = 0;\n this._alfenControlProbeOkUntilByKey = new Map();\n // The official ACE v1.0 guide defines protocol addresses as document register - 1.\n // Existing NexoWatt installations therefore keep that audited layout as the first\n // and canonical candidate. A small number of current NG9xx field installations,\n // however, answer with exception 2 on the canonical write and expose the same\n // control block on the direct table address. The compatibility probe is deliberately\n // runtime-only and never changes template/alias definitions.\n this._alfenControlVariantByKey = new Map();\n this._alfenReadAddressOffsetByKey = new Map();\n this._alfenReadWordOrderByKey = new Map();\n this._alfenReadByteOrderByKey = new Map();\n this._alfenUnsupportedLogTsByKey = new Map();\n this._alfenWriteTraceCountByKey = new Map();\n this._alfenVariantLogCountByKey = new Map();\n this._alfenAddressCompatibilityProbe = this._isAlfenProfile && alfenHints.disableAddressCompatibilityProbe !== true;\n this._alfenDirectAddressOffset = (() => {\n const n = Number(alfenHints.directTableAddressOffset ?? alfenHints.compatibilityAddressOffset ?? 1);\n return Number.isFinite(n) && Number.isInteger(n) && Math.abs(n) <= 2 && n !== 0 ? n : 1;\n })();\n const alfenBackoffRaw = Number(alfenHints.controlUnsupportedBackoffMs ?? hints.unsupportedWriteCooldownMs ?? hints.writeRejectBackoffMs ?? 3600000);\n this._alfenControlUnsupportedBackoffMs = Number.isFinite(alfenBackoffRaw) && alfenBackoffRaw > 0 ? alfenBackoffRaw : 3600000;\n const alfenOkRaw = Number(alfenHints.controlProbeOkCacheMs ?? 60000);\n this._alfenControlProbeOkCacheMs = Number.isFinite(alfenOkRaw) && alfenOkRaw > 0 ? alfenOkRaw : 60000;\n\n this.optionalReadErrorLogLevel = String(hints.optionalReadErrorLogLevel || hints.optionalReadLogLevel || 'warn').toLowerCase();\n this.disableAddressFallbackOffsets = (hints.disableAddressFallbackOffsets === true || hints.disableAddressFallbacks === true);\n this._serialDefaults = (hints && typeof hints.serialDefaults === 'object' && hints.serialDefaults) ? hints.serialDefaults : null;\n this._asciiResponseStart = String((c.asciiResponseStart ?? hints.asciiResponseStart ?? (this._serialDefaults && this._serialDefaults.asciiResponseStart) ?? ':')).trim() || ':';\n\n // Optional SolaX VPP Mode-4 block write (new protocol requires multi-write\n // starting at 0x00A0 with a fixed length for the selected mode).\n // Configured via template.driverHints.modbus.solaxVppMode4.\n this._solaxVppMode4 = (hints && typeof hints.solaxVppMode4 === 'object') ? hints.solaxVppMode4 : null;\n\n // Optional SolaX VPP Mode-8 block write (PV & BAT individual setting - duration mode).\n // Configured via template.driverHints.modbus.solaxVppMode8.\n this._solaxVppMode8 = (hints && typeof hints.solaxVppMode8 === 'object') ? hints.solaxVppMode8 : null;\n\n // Optional FoxESS Remote Control block write (battery power target needs a multi-write starting at 46001).\n // Configured via template.driverHints.modbus.foxessRemoteControl.\n this._foxessRemoteControl = (hints && typeof hints.foxessRemoteControl === 'object') ? hints.foxessRemoteControl : null;\n\n // Optional Sungrow signed battery power control. Sungrow SH/Logger/iHM use separate\n // registers for mode, charge/discharge command and unsigned power. This helper exposes\n // a single signed W datapoint (+ discharge / - charge / 0 stop) while writing the required\n // companion registers automatically.\n // Configured via template.driverHints.modbus.sungrowSignedPowerControl(s).\n const sgPc = hints && (hints.sungrowSignedPowerControls || hints.sungrowSignedPowerControl || hints.sungrowPowerControl);\n this._sungrowSignedPowerControls = Array.isArray(sgPc) ? sgPc : (sgPc && typeof sgPc === 'object' ? [sgPc] : []);\n // Cache per helper profile when the mandatory Sungrow EMS/VPP mode register was\n // last written. Sungrow battery dispatch is exposed to EOS/EMS as one signed\n // power datapoint, but protocol-wise it needs mode + command + power + heartbeat.\n // The mode is a relatively static prerequisite and should not be spammed for every\n // power update via WiNet-S/WiNet-S2/Logger1000.\n this._sungrowModeLastWriteAt = new Map();\n\n this.protocol = deviceConfig.protocol; // modbusTcp or modbusRtu\n // Treat 0 or invalid values as \"use default\" (the UI often uses 0 to mean \"not set\").\n const cfgTimeout = Number(c.timeoutMs);\n const hintTimeout = Number(hints.timeoutMs);\n const globalTimeout = Number(this.global.modbusTimeoutMs);\n\n if (Number.isFinite(cfgTimeout) && cfgTimeout > 0) {\n this.timeoutMs = cfgTimeout;\n } else if (Number.isFinite(hintTimeout) && hintTimeout > 0) {\n this.timeoutMs = hintTimeout;\n } else if (Number.isFinite(globalTimeout) && globalTimeout > 0) {\n this.timeoutMs = globalTimeout;\n } else {\n this.timeoutMs = 2000;\n }\n\n // Keep manual vs. auto-discovered values separate.\n // - manualUnitId / manualAddressOffset come from the device config\n // - autoUnitId / autoAddressOffset can be discovered at runtime (e.g. SunSpec base scan)\n const cfgUnitId = Number(c.unitId);\n const hintUnitId = Number(hints.unitIdDefault);\n const hintTcpUnitId = Number(hints.tcpUnitIdDefault ?? hints.unitIdDefaultTcp ?? hints.modbusTcpUnitIdDefault);\n const isTcpProtocol = String(deviceConfig.protocol || '').toLowerCase() === 'modbustcp';\n const rawEnforceUnitIdDefault = (c.enforceUnitIdDefault ?? hints.enforceUnitIdDefault ?? false);\n const enforceUnitIdDefault = rawEnforceUnitIdDefault === true || String(rawEnforceUnitIdDefault).toLowerCase() === 'true';\n const rawEnforceTcpUnitIdDefault = (c.enforceTcpUnitIdDefault ?? c.enforceUnitIdDefaultTcp ?? hints.enforceTcpUnitIdDefault ?? hints.enforceUnitIdDefaultTcp ?? false);\n const enforceTcpUnitIdDefault = rawEnforceTcpUnitIdDefault === true || String(rawEnforceTcpUnitIdDefault).toLowerCase() === 'true';\n\n if (isTcpProtocol && enforceTcpUnitIdDefault && Number.isFinite(hintTcpUnitId) && hintTcpUnitId > 0) {\n // TCP-only fixed Unit-ID. Useful for devices such as KEBA P40 where TCP uses 255,\n // while RTU installations may still use a user-configured slave address.\n this.manualUnitId = hintTcpUnitId;\n } else if (enforceUnitIdDefault && Number.isFinite(hintUnitId) && hintUnitId > 0) {\n // Some Modbus profiles use fixed server/unit addresses per register group.\n // For those templates, stale admin configs must not override the protocol value\n // (e.g. Alfen NG9xx: socket1=1, socket2=2, station/SCN=200).\n this.manualUnitId = hintUnitId;\n } else if (Number.isFinite(cfgUnitId) && cfgUnitId > 0) {\n this.manualUnitId = cfgUnitId;\n } else if (isTcpProtocol && Number.isFinite(hintTcpUnitId) && hintTcpUnitId > 0) {\n this.manualUnitId = hintTcpUnitId;\n } else if (Number.isFinite(hintUnitId) && hintUnitId > 0) {\n this.manualUnitId = hintUnitId;\n } else {\n this.manualUnitId = 1;\n }\n this.autoUnitId = null;\n this.unitId = this.manualUnitId;\n this._tcpCurrentUnitId = null;\n\n const forcedAddressOffsetRaw = (c.forceAddressOffset ?? hints.forceAddressOffset ?? hints.enforcedAddressOffset);\n const forcedAddressOffset = Number(forcedAddressOffsetRaw);\n if (this._isAlfenProfile) {\n // Alfen ACE templates are audited as protocol addresses already. Force offset 0 even\n // if an older adapter configuration still contains addressOffset=1/-1.\n this.manualAddressOffset = 0;\n } else if (forcedAddressOffsetRaw !== undefined && forcedAddressOffsetRaw !== null && forcedAddressOffsetRaw !== '' && Number.isFinite(forcedAddressOffset)) {\n // Template/device enforced offset. Used when template addresses are already protocol addresses\n // and a stale manual/global offset would shift all registers to the wrong place.\n this.manualAddressOffset = forcedAddressOffset;\n } else {\n const hintAddressOffset = Number(hints.addressOffsetDefault ?? hints.defaultAddressOffset);\n if (Number.isFinite(Number(c.addressOffset))) {\n this.manualAddressOffset = Number(c.addressOffset);\n } else if (Number.isFinite(hintAddressOffset)) {\n this.manualAddressOffset = hintAddressOffset;\n } else {\n this.manualAddressOffset = Number(this.global.registerAddressOffset ?? 0);\n }\n }\n this.autoAddressOffset = 0;\n\n this._disableAddressFallbackOffsets =\n this._isAlfenProfile ||\n hints.disableAddressFallbackOffsets === true ||\n hints.disableFallbackAddressOffsets === true ||\n hints.disableOffByOneFallback === true;\n\n // Optional driver hints from templates (best-effort)\n // (hints already defined above)\n this._autoSunSpec = (hints.autoSunSpec === true) || (hints.sunspec === true);\n this._sunSpecTemplateBase = Number(hints.sunSpecTemplateBase ?? 40000);\n this._sunSpecScanBases = Array.isArray(hints.sunSpecScanBases) ? hints.sunSpecScanBases.map(Number) : null;\n this._sunSpecScanUnitIds = Array.isArray(hints.sunSpecScanUnitIds) ? hints.sunSpecScanUnitIds.map(Number) : null;\n this._sunSpecScanFcs = Array.isArray(hints.sunSpecScanFunctionCodes) ? hints.sunSpecScanFunctionCodes.map(Number) : null;\n this._sunSpecDiscovered = false;\n this._sunSpecFc = null; // FC used for SunSpec registers (3/4)\n this._sunSpecFoundBase = null; // discovered base register for 'SunS'\n this._sunSpecModelsById = new Map(); // modelId -> [{offset,len}]\n this._sunSpecModelsScanned = false;\n\n // Modbus pacing/backoff:\n // Some devices (especially via monitoring modules) require a minimum delay between two Modbus commands.\n // If we hammer the device with too many back-to-back reads/writes, it may stop responding (timeouts)\n // until the TCP session is reset.\n const rawMinCmdInterval = (c.minCommandIntervalMs ?? hints.minCommandIntervalMs ?? hints.minIntervalMs ?? this.global.modbusMinCommandIntervalMs ?? 0);\n this.minCommandIntervalMs = Number(rawMinCmdInterval);\n if (!Number.isFinite(this.minCommandIntervalMs) || this.minCommandIntervalMs < 0) this.minCommandIntervalMs = 0;\n\n const rawReconnectBackoff = (c.reconnectBackoffMs ?? hints.reconnectBackoffMs ?? this.global.modbusReconnectBackoffMs ?? 0);\n this.reconnectBackoffMs = Number(rawReconnectBackoff);\n if (!Number.isFinite(this.reconnectBackoffMs) || this.reconnectBackoffMs < 0) this.reconnectBackoffMs = 0;\n\n const rawMaxBackoff = (c.maxReconnectBackoffMs ?? hints.maxReconnectBackoffMs ?? this.global.modbusMaxReconnectBackoffMs ?? 30000);\n this.maxReconnectBackoffMs = Number(rawMaxBackoff);\n if (!Number.isFinite(this.maxReconnectBackoffMs) || this.maxReconnectBackoffMs < 0) this.maxReconnectBackoffMs = 30000;\n if (this.maxReconnectBackoffMs < this.reconnectBackoffMs) this.maxReconnectBackoffMs = this.reconnectBackoffMs;\n\n // Maximum Modbus register span per read request (best-effort).\n // Conservative default: many embedded devices reject big reads or requests that\n // cross reserved register gaps. Templates/users can still raise this value.\n const rawMaxReadRegs = (c.maxReadRegs ?? hints.maxReadRegs ?? hints.maxReadRegisters ?? this.global.modbusMaxReadRegs ?? 40);\n this.maxReadRegs = Number(rawMaxReadRegs);\n if (!Number.isFinite(this.maxReadRegs) || this.maxReadRegs <= 0) this.maxReadRegs = 40;\n\n const rawStrictContiguousReads = (c.strictContiguousReads ?? c.strictReadGroups ?? hints.strictContiguousReads ?? hints.strictReadGroups ?? hints.noReadGaps ?? this.global.modbusStrictContiguousReads ?? true);\n this.strictContiguousReads = rawStrictContiguousReads === true || String(rawStrictContiguousReads).toLowerCase() === 'true';\n\n const rawIsolateReadDatapoints = (c.isolateReadDatapoints ?? c.isolateModbusReadDatapoints ?? c.isolateReads ?? hints.isolateReadDatapoints ?? hints.isolateModbusReadDatapoints ?? hints.isolateReads ?? false);\n this.isolateReadDatapoints = rawIsolateReadDatapoints === true || String(rawIsolateReadDatapoints).toLowerCase() === 'true';\n\n // Optional best-effort reads for large vendor templates. Some Modbus devices abort\n // the TCP session when a request hits optional/reserved register ranges. With this\n // enabled, non-critical read groups are skipped temporarily after a failure while\n // required live values can continue to update.\n const rawContinueOnReadError = (c.continueOnReadError ?? c.ignoreOptionalReadErrors ?? hints.continueOnReadError ?? hints.ignoreOptionalReadErrors ?? this.global.modbusContinueOnReadError ?? true);\n this.continueOnReadError = rawContinueOnReadError === true || String(rawContinueOnReadError).toLowerCase() === 'true';\n\n // Generic defensive recovery for older templates: if a device rejects a Modbus\n // read group with exception 2/3, recover by splitting the group down to single\n // datapoints and keep the values that are actually supported. If every group\n // fails, the poll still fails so a wrong IP/template does not look healthy.\n const rawAdaptiveReadSplit = (c.adaptiveReadSplit ?? c.adaptiveModbusReadSplit ?? hints.adaptiveReadSplit ?? hints.adaptiveReadRecovery ?? this.global.modbusAdaptiveReadSplit ?? true);\n this.adaptiveReadSplit = rawAdaptiveReadSplit !== false && String(rawAdaptiveReadSplit).toLowerCase() !== 'false';\n\n const rawSoftIllegalAddressReads = (c.softIllegalAddressReads ?? c.softIllegalReads ?? c.continueOnIllegalAddress ?? hints.softIllegalAddressReads ?? hints.softIllegalReads ?? hints.continueOnIllegalAddress ?? this.global.modbusSoftIllegalAddressReads ?? true);\n this.softIllegalAddressReads = rawSoftIllegalAddressReads !== false && String(rawSoftIllegalAddressReads).toLowerCase() !== 'false';\n\n const rawSplitFailedReadGroupsMs = (c.splitFailedReadGroupsMs ?? hints.splitFailedReadGroupsMs ?? this.global.modbusSplitFailedReadGroupsMs ?? 600000);\n this.splitFailedReadGroupsMs = Number(rawSplitFailedReadGroupsMs);\n if (!Number.isFinite(this.splitFailedReadGroupsMs) || this.splitFailedReadGroupsMs < 0) this.splitFailedReadGroupsMs = 600000;\n this._readGroupForceSplitUntil = new Map();\n this._readGroupSplitWarnUntil = new Map();\n\n const requiredReadDpIdsRaw = (c.requiredReadDpIds ?? hints.requiredReadDpIds ?? hints.requiredDpIds ?? []);\n const requiredReadDpIds = Array.isArray(requiredReadDpIdsRaw) ? requiredReadDpIdsRaw : [];\n this.requiredReadDpIds = new Set(requiredReadDpIds.map(x => String(x)).filter(Boolean));\n\n const rawSkipFailedReadGroupsMs = (c.skipFailedReadGroupsMs ?? hints.skipFailedReadGroupsMs ?? 300000);\n this.skipFailedReadGroupsMs = Number(rawSkipFailedReadGroupsMs);\n if (!Number.isFinite(this.skipFailedReadGroupsMs) || this.skipFailedReadGroupsMs < 0) this.skipFailedReadGroupsMs = 300000;\n\n this._readGroupSkipUntil = new Map();\n this._readGroupWarnUntil = new Map();\n\n // Optional, per-write component identity checks. FENECON/OpenEMS write-access\n // blocks can move after an app update. A cached identity probe prevents a\n // documented sample address from being written when it no longer belongs to\n // the expected component.\n this._verifiedWriteComponentIds = new Map();\n\n\n this._lastCommandAt = 0;\n this._ioQueue = Promise.resolve();\n this._failStreak = 0;\n this._nextConnectAt = 0;\n this._connectWaitWarnAt = 0;\n this._busySince = 0;\n\n // Independent hard timeouts around Modbus operations. This protects the adapter from\n // rare cases where the underlying library/socket never resolves after a device-side\n // timeout. Without this guard the per-device IO queue can remain pending forever and\n // the adapter will not recover until restart.\n const rawOperationTimeout = (c.operationTimeoutMs ?? c.hardTimeoutMs ?? hints.operationTimeoutMs ?? hints.hardTimeoutMs ?? this.global.modbusOperationTimeoutMs);\n const opDefault = Math.max(Number(this.timeoutMs || 0) * 2, Number(this.timeoutMs || 0) + 1500, 5000);\n this.operationTimeoutMs = Number(rawOperationTimeout);\n if (!Number.isFinite(this.operationTimeoutMs) || this.operationTimeoutMs <= 0) this.operationTimeoutMs = opDefault;\n this.operationTimeoutMs = Math.max(this.operationTimeoutMs, Number(this.timeoutMs || 0) + 250);\n\n const rawConnectTimeout = (c.connectTimeoutMs ?? hints.connectTimeoutMs ?? this.global.modbusConnectTimeoutMs);\n this.connectTimeoutMs = Number(rawConnectTimeout);\n if (!Number.isFinite(this.connectTimeoutMs) || this.connectTimeoutMs <= 0) this.connectTimeoutMs = Math.max(this.operationTimeoutMs, Number(this.timeoutMs || 0) + 1500, 5000);\n\n // Optional pre-write unlock sequence (device-specific; configured via template driverHints)\n this._writeUnlock = null;\n this._writeUnlockUntil = 0;\n\n // Allow per-device override via connection settings\n if (typeof c.autoSunSpec === 'boolean') this._autoSunSpec = c.autoSunSpec;\n if (Number.isFinite(Number(c.sunSpecTemplateBase))) this._sunSpecTemplateBase = Number(c.sunSpecTemplateBase);\n\n // Template-defined write-unlock sequence (e.g. SolaX requires UnlockPassword before VPP writes)\n // Structure example in templates.json:\n // driverHints.modbus.writeUnlock = {\n // fc: 6,\n // address: 0,\n // dataType: 'uint16',\n // length: 1,\n // passwordField: 'writePassword',\n // defaultPassword: 2014,\n // cacheMs: 5000\n // }\n const wh = (hints && (hints.writeUnlock || hints.unlock)) ? (hints.writeUnlock || hints.unlock) : null;\n if (wh && typeof wh === 'object') {\n const addr = Number(wh.address);\n if (Number.isFinite(addr)) {\n this._writeUnlock = {\n fc: Number(wh.fc ?? 6),\n address: addr,\n length: Number(wh.length ?? 1),\n dataType: (wh.dataType || 'uint16').toString(),\n passwordField: (wh.passwordField || 'writePassword').toString(),\n defaultPassword: (wh.defaultPassword ?? wh.password ?? null),\n cacheMs: Number(wh.cacheMs ?? 0),\n };\n }\n } else if (hints && hints.unlockPassword === true) {\n // Backwards-compatible shorthand: enable default unlock register @0 (FC6 uint16)\n this._writeUnlock = { fc: 6, address: 0, length: 1, dataType: 'uint16', passwordField: 'writePassword', defaultPassword: null, cacheMs: 0 };\n }\n\n this.wordOrder = normalizeWordOrder(c.wordOrder || 'be');\n this.byteOrder = normalizeByteOrder(c.byteOrder || 'be');\n }\n\n\n _isTcpOpen() {\n if (this.protocol !== 'modbusTcp') return true;\n const c = this.client;\n if (!c) return false;\n\n try {\n if (typeof c.isOpen === 'boolean') return c.isOpen;\n if (typeof c.isOpen === 'function') return !!c.isOpen();\n } catch (_) {\n // ignore\n }\n\n // modbus-serial internal port wrappers\n try {\n const p = c._port;\n // If modbus-serial detached its underlying TCP socket/port wrapper, treat as closed.\n // This prevents errors like: \"Cannot read properties of null (reading 'writeRegister')\".\n if (p === null) return false;\n if (p) {\n if (typeof p.isOpen === 'boolean') return p.isOpen;\n if (typeof p.isOpen === 'function') return !!p.isOpen();\n if (typeof p.destroyed === 'boolean') return !p.destroyed;\n if (p._client && typeof p._client.destroyed === 'boolean') return !p._client.destroyed;\n if (p._socket && typeof p._socket.destroyed === 'boolean') return !p._socket.destroyed;\n if (p.socket && typeof p.socket.destroyed === 'boolean') return !p.socket.destroyed;\n }\n } catch (_) {\n // ignore\n }\n\n // If we cannot determine, assume open and let real operations fail\n return true;\n }\n\n\n _makeTimeoutError(label, timeoutMs, code) {\n const ms = Number(timeoutMs || 0);\n const err = new Error(`${label || 'Modbus operation'} hard-timeout after ${ms} ms`);\n err.code = code || 'E_MODBUS_OPERATION_TIMEOUT';\n return err;\n }\n\n _forceCloseTcpClient(client) {\n if (!client) return;\n\n // modbus-serial close() is best-effort. On half-open TCP sessions we also try to\n // destroy the underlying socket so pending read/write callbacks are released.\n try { client.close(() => {}); } catch (_) {}\n\n try {\n const p = client._port;\n const candidates = [];\n if (p) {\n candidates.push(p);\n if (p._client) candidates.push(p._client);\n if (p._socket) candidates.push(p._socket);\n if (p.socket) candidates.push(p.socket);\n if (p.client) candidates.push(p.client);\n }\n for (const sock of candidates) {\n if (!sock) continue;\n try { if (typeof sock.setKeepAlive === 'function') sock.setKeepAlive(false); } catch (_) {}\n try { if (typeof sock.end === 'function') sock.end(); } catch (_) {}\n try { if (typeof sock.destroy === 'function') sock.destroy(); } catch (_) {}\n }\n } catch (_) {}\n }\n\n async _withHardTimeout(promise, timeoutMs, label, onTimeout) {\n const ms = Number(timeoutMs || 0);\n if (!Number.isFinite(ms) || ms <= 0) return await promise;\n\n let timer = null;\n let timedOut = false;\n\n const op = Promise.resolve(promise).catch((err) => {\n // If the operation rejects after our hard timeout already fired, suppress the\n // late rejection. The caller has already moved on with a clean reconnect.\n if (timedOut) {\n try {\n this.adapter.log.debug(`[${this.device?.id || 'modbus'}] Late Modbus operation rejection after timeout ignored: ${err && err.message ? err.message : err}`);\n } catch (_) {}\n return new Promise(() => {});\n }\n throw err;\n });\n\n const timeout = new Promise((_, reject) => {\n timer = setTimeout(() => {\n timedOut = true;\n const err = this._makeTimeoutError(label, ms, label && String(label).toLowerCase().includes('connect') ? 'E_MODBUS_CONNECT_TIMEOUT' : 'E_MODBUS_OPERATION_TIMEOUT');\n try { if (typeof onTimeout === 'function') onTimeout(err); } catch (_) {}\n reject(err);\n }, ms);\n try { if (timer && typeof timer.unref === 'function') timer.unref(); } catch (_) {}\n });\n\n try {\n return await Promise.race([op, timeout]);\n } finally {\n if (timer) clearTimeout(timer);\n }\n }\n\n _markDisconnected(err) {\n this.connected = false;\n this.connecting = false;\n\n // A reconnect can follow a device/FEMS restart or an app update. Re-run all\n // movable-component identity checks before the next write instead of trusting\n // a component layout cached from the previous connection.\n try { this._verifiedWriteComponentIds?.clear(); } catch (_) {}\n\n // Backoff on repeated transport errors. Some devices will stop responding if polled too hard.\n // A short cooldown prevents rapid reconnect loops and gives the device time to recover.\n try {\n const now = Date.now();\n const base = Math.max(Number(this.reconnectBackoffMs || 0), Number(this.minCommandIntervalMs || 0), 0);\n if (base > 0) {\n this._failStreak = Math.min((this._failStreak || 0) + 1, 10);\n const max = Number(this.maxReconnectBackoffMs || 30000);\n const delay = Math.min(base * Math.pow(2, this._failStreak - 1), max);\n this._nextConnectAt = now + delay;\n }\n } catch (_) {\n // ignore\n }\n\n if (this.protocol === 'modbusTcp') {\n const oldClient = this.client;\n if (oldClient) this._forceCloseTcpClient(oldClient);\n // Force a clean client for the next connect attempt (avoids stale sockets after ECONNRESET/timeouts)\n if (this.client === oldClient) this.client = null;\n }\n\n // Break a possibly poisoned IO queue after transport loss. This is safe because the\n // stale client/socket has just been closed; new operations will reconnect first.\n try { this._ioQueue = Promise.resolve(); } catch (_) {}\n }\n\n\n _getSerialOption(key, fallback) {\n const c = this.device?.connection || {};\n const defs = this._serialDefaults || null;\n const enforce = !!(defs && defs.enforce);\n if (enforce && defs && defs[key] !== undefined) return defs[key];\n const raw = c[key];\n if (raw !== undefined && raw !== null && raw !== '') return raw;\n if (defs && defs[key] !== undefined) return defs[key];\n return fallback;\n }\n\n _getSerialConnOpts() {\n return {\n path: (this._getSerialOption('path', this.device?.connection?.path || '') || '').toString().trim(),\n baudRate: Number(this._getSerialOption('baudRate', 9600)),\n parity: (this._getSerialOption('parity', 'none') || 'none').toString(),\n dataBits: Number(this._getSerialOption('dataBits', 8)),\n stopBits: Number(this._getSerialOption('stopBits', 1)),\n responseStart: (String(this._asciiResponseStart || ':').trim() || ':').charAt(0),\n };\n }\n\n async connect() {\n if (this.connected) return;\n\n // If another caller is already connecting, wait for it instead of returning early.\n // Returning early while connected=false lets the next read continue against a not-yet-open\n // TCP client and can permanently poison the queue on slow devices.\n if (this.connecting) {\n const started = Date.now();\n const maxWait = Math.max(Number(this.connectTimeoutMs || 0), Number(this.operationTimeoutMs || 0), 5000);\n while (this.connecting && !this.connected && (Date.now() - started) < maxWait) {\n await sleep(50);\n }\n if (this.connected) return;\n if (this.connecting) {\n const err = this._makeTimeoutError('Modbus TCP connect wait', maxWait, 'E_MODBUS_CONNECT_TIMEOUT');\n this._markDisconnected(err);\n throw err;\n }\n }\n\n this.connecting = true;\n\n // Respect reconnect backoff (prevents hammering devices that temporarily stop responding)\n try {\n const now = Date.now();\n if (this._nextConnectAt && now < this._nextConnectAt) {\n await sleep(this._nextConnectAt - now);\n }\n } catch (_) {\n // ignore\n }\n\n const c = this.device.connection || {};\n try {\n if (this.protocol === 'modbusTcp') {\n const host = c.host;\n const port = Number(c.port || 502);\n\n // Always start with a clean client. Some devices/field networks close idle sockets;\n // modbus-serial may keep stale socket handles after ECONNRESET/timeout.\n try {\n if (this.client) this._forceCloseTcpClient(this.client);\n } catch (_) {}\n\n const tcpClient = new ModbusRTU();\n this.client = tcpClient;\n\n const connectPromise = new Promise((resolve, reject) => {\n tcpClient.connectTCP(host, { port }, (err) => err ? reject(err) : resolve());\n });\n\n await this._withHardTimeout(\n connectPromise,\n this.connectTimeoutMs,\n `Modbus TCP connect ${host || ''}:${port}`,\n () => {\n this._forceCloseTcpClient(tcpClient);\n if (this.client === tcpClient) this.client = null;\n }\n );\n\n // The connection may have completed after a timeout and been replaced/closed.\n if (this.client !== tcpClient) {\n const err = new Error('Modbus TCP connect completed on stale client');\n err.code = 'ERR_SOCKET_CLOSED';\n throw err;\n }\n\n // Best-effort: enable TCP keepalive on the underlying socket if accessible\n try {\n const p = this.client && this.client._port ? this.client._port : null;\n const sock = p && (p._client || p._socket || p.socket || p);\n if (sock && typeof sock.setKeepAlive === 'function') sock.setKeepAlive(true, 10000);\n } catch (_) {}\n\n this.client.setID(this.unitId);\n this._tcpCurrentUnitId = this.unitId;\n this.client.setTimeout(this.timeoutMs);\n } else if (this.protocol === 'modbusRtu') {\n const serial = this._getSerialConnOpts();\n if (!this.rtuBus) {\n const { key, bus } = acquireBus(this.adapter, {\n path: serial.path,\n baudRate: serial.baudRate,\n parity: serial.parity,\n dataBits: serial.dataBits,\n stopBits: serial.stopBits,\n });\n this.rtuBusKey = key;\n this.rtuBus = bus;\n }\n await this.rtuBus.ensureConnected();\n } else if (this.protocol === 'modbusAscii') {\n const serial = this._getSerialConnOpts();\n if (!this.asciiBus) {\n const { key, bus } = acquireAsciiBus(this.adapter, {\n path: serial.path,\n baudRate: serial.baudRate,\n parity: serial.parity,\n dataBits: serial.dataBits,\n stopBits: serial.stopBits,\n responseStart: serial.responseStart,\n });\n this.asciiBusKey = key;\n this.asciiBus = bus;\n }\n await this.asciiBus.ensureConnected();\n } else {\n throw new Error(`Unsupported Modbus protocol: ${this.protocol}`);\n }\n\n this.connected = true;\n this._failStreak = 0;\n this._nextConnectAt = 0;\n this.adapter.log.info(`[${this.device.id}] Modbus connected (${this.protocol})`);\n\n // Optional SunSpec base / unit-id discovery (only when enabled via template hints).\n try {\n await this._maybeDiscoverSunSpec();\n } catch (e) {\n // Discovery must never break connectivity.\n this.adapter.log.debug(`[${this.device.id}] SunSpec discovery error: ${e && e.message ? e.message : e}`);\n }\n } catch (e) {\n // Ensure we always reset the internal state and apply backoff on connect failures\n if (isTransportError(e)) {\n this._markDisconnected(e);\n } else {\n // still close any stale socket to avoid half-open sessions\n this._markDisconnected(e);\n }\n throw e;\n } finally {\n this.connecting = false;\n }\n }\n\n async disconnect() {\n try {\n if (this.protocol === 'modbusTcp') {\n if (this.client) {\n this._forceCloseTcpClient(this.client);\n this.client = null;\n }\n } else if (this.protocol === 'modbusRtu') {\n if (this.rtuBusKey) {\n releaseBus(this.rtuBusKey);\n }\n this.rtuBus = null;\n this.rtuBusKey = null;\n } else if (this.protocol === 'modbusAscii') {\n if (this.asciiBusKey) {\n releaseAsciiBus(this.asciiBusKey);\n }\n this.asciiBus = null;\n this.asciiBusKey = null;\n }\n } finally {\n this.connected = false;\n this.connecting = false;\n this._tcpCurrentUnitId = null;\n this._verifiedWriteComponentIds.clear();\n }\n }\n\n async ensureConnected() {\n if (this.connected) {\n if (this.protocol === 'modbusTcp' && !this._isTcpOpen()) {\n this._markDisconnected(new Error('Port Not Open'));\n } else {\n return true;\n }\n }\n try {\n await this.connect();\n return this.connected;\n } catch (e) {\n this.connected = false;\n throw e;\n }\n }\n\n _setUnitId(id) {\n const uid = Number(id);\n if (!Number.isFinite(uid) || uid < 0) return;\n this.unitId = uid;\n if (this.protocol === 'modbusTcp' && this.client && typeof this.client.setID === 'function') {\n try { this.client.setID(uid); this._tcpCurrentUnitId = uid; } catch (_) {}\n }\n }\n\n _operationUnitId(unitIdOverride) {\n const n = Number(unitIdOverride);\n if (Number.isFinite(n) && n > 0) return Math.trunc(n);\n const base = Number(this.unitId);\n return (Number.isFinite(base) && base > 0) ? Math.trunc(base) : 1;\n }\n\n _sourceUnitId(src) {\n if (!src) return this._operationUnitId();\n const raw = (src.unitId ?? src.slaveId ?? src.serverAddress ?? src.deviceId ?? src.modbusUnitId);\n return this._operationUnitId(raw);\n }\n\n _setTcpRequestUnitId(uid) {\n const id = this._operationUnitId(uid);\n if (this.protocol !== 'modbusTcp' || !this.client || typeof this.client.setID !== 'function') return id;\n // modbus-serial keeps the Unit-ID/Slave-ID as mutable state on the TCP client.\n // Set it directly before every operation so templates can safely address vendors\n // such as Alfen where one IP exposes different register groups through different Unit-IDs.\n try {\n if (this._tcpCurrentUnitId !== id) {\n this.client.setID(id);\n this._tcpCurrentUnitId = id;\n }\n } catch (_) {}\n return id;\n }\n\n _addr(src) {\n let a = Number(src?.address || 0);\n\n // Optional per-datapoint address base offset via device settings.\n // Useful for devices that expose multiple blocks (e.g. different coil blocks, configurable start address).\n // Example in template source:\n // { address: 0, addressOffsetSetting: 'coilReadOffset' }\n let extra = 0;\n const key = src?.addressOffsetSetting;\n const isFeneconControllerOffset = key === 'feneconCtrlBalancingOffset';\n if (key) {\n const k = String(key);\n if (isFeneconControllerOffset) {\n // This setting moves a writable component block. Invalid explicit values\n // must not silently select the default block or truncate an address.\n const owner = Object.prototype.hasOwnProperty.call(this.device || {}, k) ? this.device : this.device?.settings;\n const present = Object.prototype.hasOwnProperty.call(owner || {}, k);\n const raw = present ? owner[k] : 0;\n const scalar = typeof raw === 'number' || (typeof raw === 'string' && raw.trim() !== '');\n const n = scalar ? Number(raw) : NaN;\n if (!Number.isInteger(n) || n < -890 || n > 64542) {\n const error = new Error('Invalid feneconCtrlBalancingOffset: expected an integer from -890 to 64542');\n error.code = 'E_MODBUS_ADDRESS_CONFIG';\n throw error;\n }\n extra = n;\n } else {\n const raw = (this.device && (this.device[k] ?? this.device?.settings?.[k]));\n const n = Number(raw);\n if (Number.isFinite(n)) extra += n;\n }\n }\n\n // SunSpec dynamic address resolution:\n // If a datapoint source specifies a SunSpec model + offset, we resolve the absolute register\n // address using the scanned SunSpec model map (modelId -> start offset).\n //\n // Example source:\n // { kind:'modbus', fc:3, sunspecModel:103, sunspecOffset:14, length:1, dataType:'int16' }\n if (src && src.sunspecModel !== undefined && src.sunspecModel !== null) {\n const modelId = Number(src.sunspecModel);\n const modelIndex = Number(src.sunspecIndex ?? src.sunspecInstance ?? 0);\n const pointOff = Number(src.sunspecOffset ?? 0);\n const templateBase = Number(this._sunSpecTemplateBase ?? 40000);\n\n if (Number.isFinite(modelId) && Number.isFinite(pointOff) && Number.isFinite(templateBase)) {\n try {\n const arr = this._sunSpecModelsById ? this._sunSpecModelsById.get(modelId) : null;\n const idx = Number.isFinite(modelIndex) ? Math.max(0, Math.trunc(modelIndex)) : 0;\n const entry = (arr && arr.length) ? arr[idx] : null;\n\n if (entry && Number.isFinite(Number(entry.offset))) {\n a = templateBase + Number(entry.offset) + pointOff;\n } else if (a === 0) {\n // Model is not present on this device -> skip this datapoint.\n a = NaN;\n }\n } catch (_) {\n // ignore and fall back to 'address'\n }\n }\n }\n\n if (this._isAlfenProfile) {\n // Never apply UI/global/auto offsets to Alfen ACE protocol addresses.\n return a;\n }\n const address = a + this.manualAddressOffset + this.autoAddressOffset + extra;\n if (isFeneconControllerOffset) {\n const length = Number(src.length ?? 1);\n if (!Number.isInteger(address) || address < 0 || !Number.isInteger(length) || length < 1 || address + length > 65536) {\n const error = new Error('Invalid FENECON controller register range after address offsets');\n error.code = 'E_MODBUS_ADDRESS_CONFIG';\n throw error;\n }\n }\n return address;\n }\n\n _addressFallbackOffsets(src) {\n if (this._disableAddressFallbackOffsets) return [];\n return (this.disableAddressFallbackOffsets ? [] : normalizeAddressFallbackOffsets(src));\n }\n\n\n _isAlfenSocketControlDpId(dpId) {\n const id = String(dpId || '');\n return id === 'sET_CHARGING_CURRENT' || id === 'cHARGE_USING_PHASES';\n }\n\n _isAlfenScnControlDpId(dpId) {\n const id = String(dpId || '');\n return id === 'sCN_MAX_CURRENT' || id === 'sCN_MAX_CURRENT_L1' || id === 'sCN_MAX_CURRENT_L2' || id === 'sCN_MAX_CURRENT_L3';\n }\n\n _isAlfenSocketControlReadDpId(dpId) {\n const id = String(dpId || '');\n return id === 'eVSE_STATE' || id === 'mODE3_STATE' || id === 'aCTUAL_APPLIED_MAX_CURRENT' ||\n id === 'mODBUS_MAX_CURRENT_VALID_TIME' || id === 'sET_CHARGING_CURRENT' ||\n id === 'aCTIVE_LOAD_BALANCING_SAFE_CURRENT' || id === 'sETPOINT_ACCOUNTED_FOR' ||\n id === 'cHARGE_USING_PHASES';\n }\n\n _isAlfenScnReadDpId(dpId) {\n const id = String(dpId || '');\n return id.startsWith('sCN_') || id.startsWith('sTATION_') || id === 'tEMPERATURE' || id === 'oCPP_STATE' || id === 'nUMBER_OF_SOCKETS';\n }\n\n _markAlfenControlUnsupported(kind, reason) {\n if (!this._isAlfenProfile) return;\n const now = Date.now();\n const backoff = Math.max(1000, Number(this._alfenControlUnsupportedBackoffMs || 3600000));\n if (kind === 'scn') this._alfenScnUnsupportedUntil = now + backoff;\n else this._alfenControlUnsupportedUntil = now + backoff;\n // Keep this quiet by default; the user-facing warning is misleading because the\n // adapter address is correct. We only need a throttled debug breadcrumb.\n const key = kind || 'socket';\n const last = Number(this._alfenUnsupportedLogTsByKey.get(key) || 0);\n if (!last || (now - last) > 300000) {\n this._alfenUnsupportedLogTsByKey.set(key, now);\n try {\n this.adapter.log.debug(`[${this.device?.id || 'modbus'}] Alfen ${key === 'scn' ? 'SCN' : 'socket'} control block not exposed; suppressing control writes for ${Math.ceil(backoff / 1000)}s.${reason ? ` ${reason}` : ''}`);\n } catch (_) {}\n }\n }\n\n _alfenUnsupportedError(kind, dpId, addr, unitId, reason) {\n const err = new Error(\n `Alfen ${kind === 'scn' ? 'SCN' : 'socket'} control block is not exposed by the charger; skipped write ${dpId || 'datapoint'} UID${this._operationUnitId(unitId)}@${addr}. ` +\n `The adapter keeps the official address first and can probe the direct table-address compatibility layout after exception 2. ` +\n `If both layouts fail, verify ACE Advanced Settings (Allow writing maximum currents and Enable sockets/SCN).${reason ? ` ${reason}` : ''}`\n );\n err.code = 'E_NEXOWATT_WRITE_UNSUPPORTED';\n err.nexowattOperation = 'write';\n err.nexowattDpId = String(dpId || '');\n err.nexowattSuppressWarn = true;\n err.nexowattUnsupportedWrite = true;\n err.nexowattUnsupportedKind = kind || 'socket';\n return err;\n }\n\n async _maybeProbeAlfenControlBeforeWrite(dp, src, addr, words, unitId) {\n if (!this._isAlfenProfile || !this._alfenProbeControlBeforeWrite) return;\n const dpId = String(dp?.id || '');\n const kind = this._isAlfenSocketControlDpId(dpId) ? 'socket' : (this._isAlfenScnControlDpId(dpId) ? 'scn' : '');\n if (!kind) return;\n\n const now = Date.now();\n const unsupportedUntil = kind === 'scn' ? Number(this._alfenScnUnsupportedUntil || 0) : Number(this._alfenControlUnsupportedUntil || 0);\n if (unsupportedUntil && now < unsupportedUntil) {\n throw this._alfenUnsupportedError(kind, dpId, addr, unitId, `Retry after ${Math.ceil((unsupportedUntil - now) / 1000)}s.`);\n }\n\n // Probe exactly the register pair/single register that would be written. The\n // Max Current register is R/W in the ACE map, so a FC03 read is a safe capability\n // test and avoids hammering unsupported FC16 writes into chargers that only expose\n // meter values.\n const key = `${kind}:${this._operationUnitId(unitId)}:${Number(addr)}:${Number(words || src?.length || 1)}`;\n const okUntil = Number(this._alfenControlProbeOkUntilByKey.get(key) || 0);\n if (okUntil && now < okUntil) return;\n\n try {\n const len = Math.max(1, Number(words || src?.length || 1));\n await this._mbReadHoldingRegisters(Number(addr), len, unitId);\n this._alfenControlProbeOkUntilByKey.set(key, Date.now() + Math.max(10000, Number(this._alfenControlProbeOkCacheMs || 60000)));\n } catch (e) {\n if (isModbusIllegalAddressOrValue(e)) {\n this._markAlfenControlUnsupported(kind, e && e.message ? e.message : String(e));\n throw this._alfenUnsupportedError(kind, dpId, addr, unitId, e && e.message ? e.message : String(e));\n }\n throw e;\n }\n }\n\n _alfenControlKindForDpId(dpId) {\n const id = String(dpId || '');\n if (this._isAlfenSocketControlDpId(id)) return 'socket';\n if (this._isAlfenScnControlDpId(id)) return 'scn';\n return '';\n }\n\n _alfenControlCacheKey(dp, src, unitId) {\n const dpId = String(dp?.id || '');\n const uid = this._operationUnitId(unitId ?? this._sourceUnitId(src));\n return `${dpId}:uid${uid}:addr${Number(src?.address)}:len${Number(src?.length || 1)}:${String(src?.dataType || 'uint16').toLowerCase()}`;\n }\n\n _alfenStrictControlAddress(dpId, addr) {\n if (!this._isAlfenProfile) return Number(addr);\n const id = String(dpId || '');\n const hints = this._alfenHints || {};\n const raw = id === 'sET_CHARGING_CURRENT'\n ? hints.maxCurrentWriteProtocolAddress\n : id === 'cHARGE_USING_PHASES'\n ? hints.chargeUsingPhasesWriteProtocolAddress\n : undefined;\n const n = Number(raw);\n return Number.isFinite(n) && n >= 0 ? n : Number(addr);\n }\n\n _alfenControlCandidateVariants(dp, src, addr, unitId, wordOrder, byteOrder) {\n const dpId = String(dp?.id || '');\n const strictAddr = Number(this._alfenStrictControlAddress(dpId, addr));\n if (!Number.isFinite(strictAddr) || strictAddr < 0) return [];\n\n const canonical = {\n id: 'document-minus-one',\n label: 'document register - 1',\n address: strictAddr,\n addressOffset: 0,\n wordOrder: normalizeWordOrder(wordOrder),\n byteOrder: normalizeByteOrder(byteOrder),\n official: true,\n };\n\n const variants = [canonical];\n if (this._alfenAddressCompatibilityProbe) {\n const offset = Number(this._alfenDirectAddressOffset || 1);\n const directAddress = strictAddr + offset;\n if (Number.isFinite(directAddress) && directAddress >= 0 && directAddress !== strictAddr) {\n variants.push({\n id: 'direct-table',\n label: `direct table address (${offset > 0 ? '+' : ''}${offset})`,\n address: directAddress,\n addressOffset: offset,\n // The ACE guide requires low-word-first. A few older/current integrations\n // expose direct table addresses with a different word layout, therefore the\n // compatibility candidate resolves the word order from the configured safe\n // current before its first write.\n wordOrder: 'auto',\n byteOrder: normalizeByteOrder(byteOrder),\n official: false,\n });\n }\n }\n\n const key = this._alfenControlCacheKey(dp, src, unitId);\n const cached = this._alfenControlVariantByKey && this._alfenControlVariantByKey.get(key);\n if (!cached || typeof cached !== 'object') return variants;\n\n const ordered = [];\n const pushUnique = (variant) => {\n if (!variant || !Number.isFinite(Number(variant.address))) return;\n const identity = `${variant.id || ''}|${Number(variant.address)}|${String(variant.wordOrder || '')}|${String(variant.byteOrder || '')}`;\n if (ordered.some(v => v._identity === identity)) return;\n ordered.push(Object.assign({}, variant, { _identity: identity }));\n };\n pushUnique(cached);\n for (const variant of variants) pushUnique(variant);\n return ordered.map(({ _identity, ...variant }) => variant);\n }\n\n _alfenSafeCurrentProtocolAddress(kind) {\n return kind === 'scn' ? 1428 : 1211;\n }\n\n _alfenPlausibleSafeCurrent(value) {\n const n = Number(value);\n // Safe current is configured in amperes. Values below 1 A are either invalid\n // for normal AC charging or a typical symptom of decoding a 32-bit float with\n // the wrong word order (subnormal number around 10^-41).\n return Number.isFinite(n) && n >= 1 && n <= 80;\n }\n\n _alfenDecodeFloat32Regs(regs, wordOrder, byteOrder) {\n if (!Array.isArray(regs) || regs.length < 2) return NaN;\n try {\n return Number(bufferToValue(regsToBuffer(regs.slice(0, 2), wordOrder, byteOrder), 'float32'));\n } catch (_) {\n return NaN;\n }\n }\n\n async _resolveAlfenVariantWordOrder(variant, kind, unitId, fallbackWordOrder, fallbackByteOrder) {\n const resolved = Object.assign({}, variant);\n const fallbackWo = normalizeWordOrder(fallbackWordOrder);\n const fallbackBo = normalizeByteOrder(fallbackByteOrder);\n resolved.byteOrder = normalizeByteOrder(resolved.byteOrder || fallbackBo);\n\n if (resolved.wordOrder !== 'auto') {\n resolved.wordOrder = normalizeWordOrder(resolved.wordOrder || fallbackWo);\n return resolved;\n }\n\n const safeCurrentAddress = this._alfenSafeCurrentProtocolAddress(kind) + Number(resolved.addressOffset || 0);\n try {\n const response = await this._mbReadHoldingRegisters(safeCurrentAddress, 2, unitId);\n const regs = Array.isArray(response) ? response : (Array.isArray(response && response.data) ? response.data : []);\n const le = this._alfenDecodeFloat32Regs(regs, 'le', resolved.byteOrder);\n const be = this._alfenDecodeFloat32Regs(regs, 'be', resolved.byteOrder);\n const leOk = this._alfenPlausibleSafeCurrent(le);\n const beOk = this._alfenPlausibleSafeCurrent(be);\n\n if (leOk && !beOk) resolved.wordOrder = 'le';\n else if (beOk && !leOk) resolved.wordOrder = 'be';\n else resolved.wordOrder = fallbackWo;\n\n resolved.safeCurrentProbe = {\n address: safeCurrentAddress,\n le,\n be,\n selected: resolved.wordOrder,\n };\n } catch (e) {\n resolved.wordOrder = fallbackWo;\n resolved.safeCurrentProbeError = e && e.message ? e.message : String(e);\n }\n return resolved;\n }\n\n _encodeAlfenControlRegs(raw, src, len, wordOrder, byteOrder) {\n const words = Math.max(1, Number(len || src?.length || 1));\n const dataType = src?.dataType || 'uint16';\n const wo = normalizeWordOrder(wordOrder);\n const bo = normalizeByteOrder(byteOrder);\n\n if (src && (src.repeatEncodedValue === true || src.repeatEncodedToLength === true || src.repeatDataTypeValue === true)) {\n const oneWordsRaw = Number(src.repeatValueWords ?? src.valueWords ?? dataTypeWordLength(dataType));\n const oneWords = Number.isFinite(oneWordsRaw) && oneWordsRaw > 0 ? Math.trunc(oneWordsRaw) : dataTypeWordLength(dataType);\n if (oneWords <= 0 || words % oneWords !== 0) {\n throw new Error(`Invalid Alfen repeatEncodedValue layout: length=${words}, valueWords=${oneWords}`);\n }\n const singleBuf = valueToBuffer(raw, dataType, oneWords * 2);\n const singleRegs = bufferToRegs(singleBuf, wo, bo);\n if (!singleRegs.length) throw new Error('Cannot encode Alfen repeated control value');\n const regs = [];\n const repeatCount = Math.trunc(words / singleRegs.length);\n for (let i = 0; i < repeatCount; i++) regs.push(...singleRegs);\n return regs.slice(0, words);\n }\n\n if (src && (src.repeatValue === true || src.repeatToLength === true || src.fillRegisters === true)) {\n const singleBuf = valueToBuffer(raw, dataType, 2);\n const singleRegs = bufferToRegs(singleBuf, wo, bo);\n return Array(words).fill(singleRegs.length ? singleRegs[0] : 0);\n }\n\n return bufferToRegs(valueToBuffer(raw, dataType, words * 2), wo, bo).slice(0, words);\n }\n\n _logAlfenControlVariant(dp, unitId, variant) {\n if (!variant || variant.id !== 'direct-table') return;\n const dpId = String(dp?.id || 'datapoint');\n const uid = this._operationUnitId(unitId);\n const key = `${dpId}|uid${uid}|${variant.id}|${variant.address}|${variant.wordOrder}|${variant.byteOrder}`;\n const count = Number(this._alfenVariantLogCountByKey.get(key) || 0);\n this._alfenVariantLogCountByKey.set(key, count + 1);\n const probe = variant.safeCurrentProbe;\n const probeText = probe\n ? ` Safe-current probe UID${uid}@${probe.address}: LE=${probe.le}, BE=${probe.be}, selected=${probe.selected}.`\n : (variant.safeCurrentProbeError ? ` Safe-current probe unavailable: ${variant.safeCurrentProbeError}.` : '');\n const line = `[${this.device?.id || 'modbus'}] Alfen ACE compatibility mode selected for ${dpId}: UID${uid} FC16@${variant.address}, wordOrder=${variant.wordOrder}, byteOrder=${variant.byteOrder}.${probeText} Canonical template/alias addresses remain unchanged.`;\n try {\n if (count < 1) this.adapter.log.warn(line);\n else this.adapter.log.debug(line);\n } catch (_) {}\n }\n\n _logAlfenAcceptedControlWrite(dp, src, unitId, fc, addr, raw, regs) {\n if (!this._isAlfenProfile) return;\n const dpId = String(dp?.id || 'datapoint');\n if (!this._alfenControlKindForDpId(dpId)) return;\n\n const hints = this._alfenHints || {};\n if (hints.acceptedWriteTrace === false || hints.logAcceptedControlWrites === false) return;\n\n const uid = this._operationUnitId(unitId ?? this._sourceUnitId(src));\n const functionCode = Number(fc || src?.fc || 16);\n const address = Number(addr);\n const words = Array.isArray(regs) ? regs.map(v => Number(v) & 0xFFFF) : [];\n const hexWords = words.map(v => `0x${v.toString(16).toUpperCase().padStart(4, '0')}`).join(',');\n const dataBytes = words\n .flatMap(v => [(v >>> 8) & 0xFF, v & 0xFF])\n .map(v => v.toString(16).toUpperCase().padStart(2, '0'))\n .join(' ');\n const key = `${dpId}|uid${uid}|fc${functionCode}|addr${address}`;\n const count = Number(this._alfenWriteTraceCountByKey.get(key) || 0);\n this._alfenWriteTraceCountByKey.set(key, count + 1);\n\n // A normal FC6/FC16 response confirms that the Modbus server accepted the request.\n // It does not by itself prove that ACE accounted the setpoint; the corresponding\n // valid-time/accounted/actual-current registers remain the authoritative readback.\n const line = `[${this.device?.id || 'modbus'}] Alfen Modbus write accepted: ${dpId} UID${uid} FC${functionCode}@${address} len=${words.length} value=${raw} regs=[${hexWords}] data=${dataBytes}. Check the ACE accounted/enabled and valid-time readbacks to confirm application.`;\n try {\n if (count < 3) this.adapter.log.info(line);\n else this.adapter.log.debug(line);\n } catch (_) {}\n }\n\n\n\n _getMirrorWriteSources(src) {\n if (!src || typeof src !== 'object') return [];\n const raw = src.mirrorWrites || src.writeMirrors || src.alsoWrite || src.mirrorWriteSources;\n if (!raw) return [];\n const arr = Array.isArray(raw) ? raw : [raw];\n return arr.filter(x => x && typeof x === 'object');\n }\n\n async _writeAlfenControlMirrorWrites(dp, src, raw, unitId, wordOrder, byteOrder, setWriteContext) {\n const mirrors = this._getMirrorWriteSources(src);\n const result = { attempts: 0, successes: 0, failures: [] };\n if (!mirrors.length) return result;\n\n for (const mirror of mirrors) {\n const m = Object.assign({}, src, mirror);\n const fc = Number(m.fc || src.fc || 16);\n const lenRaw = Number(m.length || src.length || 1);\n const len = Number.isFinite(lenRaw) && lenRaw > 0 ? Math.trunc(lenRaw) : 1;\n const addr = this._addr(m);\n const uid = this._sourceUnitId(m);\n const wo = m.wordOrder || wordOrder || src.wordOrder || this.wordOrder;\n const bo = m.byteOrder || byteOrder || src.byteOrder || this.byteOrder;\n const dataType = m.dataType || src.dataType || 'uint16';\n const optional = m.optional !== false || m.ignoreErrors === true || m.ignoreError === true;\n const label = String(m.label || m.name || m.description || `${dp?.id || 'datapoint'} mirror UID${this._operationUnitId(uid)}@${addr}`);\n result.attempts += 1;\n\n if (!Number.isFinite(addr)) {\n const err = new Error(`Invalid Alfen mirror write address for ${label}`);\n result.failures.push({ label, error: err.message });\n if (optional) continue;\n throw err;\n }\n\n try {\n let regs;\n if (m.repeatEncodedValue === true || m.repeatEncodedToLength === true || m.repeatDataTypeValue === true) {\n const oneWordsRaw = Number(m.repeatValueWords ?? m.valueWords ?? dataTypeWordLength(dataType));\n const oneWords = Number.isFinite(oneWordsRaw) && oneWordsRaw > 0 ? Math.trunc(oneWordsRaw) : dataTypeWordLength(dataType);\n if (oneWords <= 0 || len % oneWords !== 0) {\n throw new Error(`Invalid mirror repeatEncodedValue layout for ${label}: length=${len}, valueWords=${oneWords}`);\n }\n const singleBuf = valueToBuffer(raw, dataType, oneWords * 2);\n const singleRegs = bufferToRegs(singleBuf, wo, bo);\n regs = [];\n const repeatCount = Math.trunc(len / singleRegs.length);\n for (let i = 0; i < repeatCount; i++) regs.push(...singleRegs);\n regs = regs.slice(0, len);\n } else {\n const buf = valueToBuffer(raw, dataType, len * 2);\n regs = bufferToRegs(buf, wo, bo).slice(0, len);\n }\n\n if (typeof setWriteContext === 'function') setWriteContext(m, fc, addr, raw, len, uid);\n if (fc === 6) {\n if (!regs.length) throw new Error(`FC6 mirror write needs one register for ${label}`);\n await this._mbWriteRegister(addr, regs[0], uid);\n } else if (fc === 16) {\n await this._mbWriteRegisters(addr, regs, uid);\n } else {\n throw new Error(`Unsupported Alfen mirror write FC=${fc} for ${label}`);\n }\n result.successes += 1;\n try {\n const mirrorKey = `ok:${label}|UID${this._operationUnitId(uid)}|${addr}`;\n if (!this._alfenMirrorWriteInfoCountByKey) this._alfenMirrorWriteInfoCountByKey = new Map();\n const cnt = Number(this._alfenMirrorWriteInfoCountByKey.get(mirrorKey) || 0);\n const line = `[${this.device?.id || 'modbus'}] Alfen mirror write OK: ${label} UID${this._operationUnitId(uid)} FC${fc}@${addr} len=${len} value=${raw}`;\n if (cnt < 3) {\n this._alfenMirrorWriteInfoCountByKey.set(mirrorKey, cnt + 1);\n this.adapter.log.info(line);\n } else {\n this.adapter.log.debug(line);\n }\n } catch (_) {}\n } catch (e) {\n const errMsg = e && e.message ? e.message : String(e);\n result.failures.push({ label, error: errMsg });\n if (optional) {\n const warnMirror = !!(m.warnOnError === true || m.warnOnFailure === true || (this._alfenHints && this._alfenHints.allIdsWriteMirrors === true));\n if (warnMirror) {\n try {\n const key = `mirror:${label}`;\n const now = Date.now();\n const last = Number(this._alfenUnsupportedLogTsByKey && this._alfenUnsupportedLogTsByKey.get(key) || 0);\n if (!last || (now - last) > 60000) {\n if (this._alfenUnsupportedLogTsByKey) this._alfenUnsupportedLogTsByKey.set(key, now);\n this.adapter.log.warn(`[${this.device?.id || 'modbus'}] Alfen optional mirror write failed: ${label}: ${errMsg}. If the charger is configured for TCP/IP EMS Control Mode=SCN, this mirror must succeed; otherwise socket writes can be visible in ioBroker but not accounted by the charger.`);\n }\n } catch (_) {}\n } else {\n try { this.adapter.log.debug(`[${this.device?.id || 'modbus'}] Alfen optional mirror write skipped: ${label}: ${errMsg}`); } catch (_) {}\n }\n continue;\n }\n throw e;\n }\n }\n return result;\n }\n\n async _writeAlfenControlAdaptive(dp, src, addr, raw, words, unitId, wordOrder, byteOrder, setWriteContext) {\n if (!this._isAlfenProfile) return false;\n const dpId = String(dp?.id || '');\n const kind = this._alfenControlKindForDpId(dpId);\n if (!kind) return false;\n\n const now = Date.now();\n const unsupportedUntil = kind === 'scn' ? Number(this._alfenScnUnsupportedUntil || 0) : Number(this._alfenControlUnsupportedUntil || 0);\n const alwaysTryControlWrites = !!(this._alfenHints && (this._alfenHints.alwaysTryControlWrites === true || this._alfenHints.probeControlBeforeWrite === false));\n if (unsupportedUntil && now < unsupportedUntil && !alwaysTryControlWrites) {\n throw this._alfenUnsupportedError(kind, dpId, addr, unitId, `Retry after ${Math.ceil((unsupportedUntil - now) / 1000)}s.`);\n }\n\n const len = Math.max(1, Number(words || src?.length || 1));\n const strictAddr = this._alfenStrictControlAddress(dpId, addr);\n if (Number.isFinite(strictAddr) && strictAddr !== Number(addr)) addr = strictAddr;\n\n const key = this._alfenControlCacheKey(dp, src, unitId);\n const cachedBefore = this._alfenControlVariantByKey && this._alfenControlVariantByKey.get(key);\n const candidates = this._alfenControlCandidateVariants(dp, src, addr, unitId, wordOrder, byteOrder);\n const tried = [];\n let lastErr = null;\n let sawIllegalAddress = false;\n\n for (const candidateRaw of candidates) {\n const isCachedCandidate = !!(cachedBefore && candidateRaw && cachedBefore.id === candidateRaw.id && Number(cachedBefore.address) === Number(candidateRaw.address));\n // The direct table-address layout is a compatibility path only. In a fresh\n // session it is attempted exclusively after the documented address returned\n // Modbus exception 2 (Illegal Data Address). A previously detected direct\n // variant is allowed to run first.\n if (candidateRaw.id === 'direct-table' && !isCachedCandidate && !sawIllegalAddress) continue;\n\n const candidate = await this._resolveAlfenVariantWordOrder(\n candidateRaw,\n kind,\n unitId,\n wordOrder,\n byteOrder,\n );\n const regs = this._encodeAlfenControlRegs(raw, src, len, candidate.wordOrder, candidate.byteOrder);\n tried.push(`${candidate.label || candidate.id}@${candidate.address}/${candidate.wordOrder}-${candidate.byteOrder}`);\n\n const skipProbe = this._alfenHints && this._alfenHints.probeControlBeforeWrite === false;\n if (!skipProbe) {\n try {\n await this._mbReadHoldingRegisters(candidate.address, len, unitId);\n } catch (e) {\n lastErr = e;\n if (isModbusIllegalAddress(e)) {\n sawIllegalAddress = true;\n if (isCachedCandidate && this._alfenControlVariantByKey) this._alfenControlVariantByKey.delete(key);\n continue;\n }\n // Exception 3 means the address exists but the requested value/layout is\n // invalid. Changing the register address would hide the real error.\n throw e;\n }\n }\n\n let primaryOk = false;\n let primaryErr = null;\n try {\n if (typeof setWriteContext === 'function') {\n setWriteContext(src, Number(src.fc || 16), candidate.address, raw, len, unitId);\n }\n if (Number(src.fc) === 6) {\n await this._mbWriteRegister(candidate.address, regs[0], unitId);\n } else {\n await this._mbWriteRegisters(candidate.address, regs.slice(0, len), unitId);\n }\n primaryOk = true;\n this._logAlfenAcceptedControlWrite(dp, src, unitId, Number(src.fc || 16), candidate.address, raw, regs.slice(0, len));\n } catch (e) {\n primaryErr = e;\n lastErr = e;\n if (isModbusIllegalAddress(e)) {\n sawIllegalAddress = true;\n if (isCachedCandidate && this._alfenControlVariantByKey) this._alfenControlVariantByKey.delete(key);\n } else {\n // Do not switch addresses for Illegal Data Value (exception 3), transport\n // errors or arbitrary protocol failures.\n throw e;\n }\n }\n\n // Preserve the existing independent mirror-write behaviour for Station/All-IDs\n // profiles. Mirrors remain explicit template targets and are not silently\n // shifted by the compatibility probe.\n const mirrorResult = await this._writeAlfenControlMirrorWrites(\n dp,\n src,\n raw,\n unitId,\n candidate.wordOrder,\n candidate.byteOrder,\n setWriteContext,\n );\n\n if (primaryOk || (mirrorResult && mirrorResult.successes > 0)) {\n if (primaryOk) {\n if (this._alfenControlVariantByKey) this._alfenControlVariantByKey.set(key, Object.assign({}, candidate));\n this._cacheAlfenReadVariantForControlBlock(\n kind,\n unitId,\n Number(candidate.addressOffset || 0),\n candidate.wordOrder,\n candidate.byteOrder,\n );\n this._logAlfenControlVariant(dp, unitId, candidate);\n } else if (mirrorResult && mirrorResult.successes > 0) {\n try {\n this.adapter.log.info(`[${this.device?.id || 'modbus'}] Alfen primary ${dpId} write UID${this._operationUnitId(unitId)}@${candidate.address} was rejected, but ${mirrorResult.successes} mirror target(s) accepted value=${raw}.`);\n } catch (_) {}\n }\n return true;\n }\n\n if (primaryErr && isModbusIllegalAddress(primaryErr)) continue;\n }\n\n const detail = tried.length ? tried.join(', ') : 'no valid candidate';\n if (lastErr) {\n this._markAlfenControlUnsupported(kind, lastErr && lastErr.message ? lastErr.message : String(lastErr));\n try {\n lastErr.message = `${lastErr.message || String(lastErr)} | Alfen tried ${detail}, value=${raw}. ` +\n `Both the documented and compatibility address layouts were rejected. In ACE Advanced Settings verify Allow writing maximum currents and Enable sockets (Socket mode).`;\n } catch (_) {}\n throw lastErr;\n }\n\n throw this._alfenUnsupportedError(kind, dpId, addr, unitId, `No Alfen control candidate accepted the write (${detail}).`);\n }\n\n _isAlfenAdaptiveReadDpId(dpId) {\n const id = String(dpId || '');\n return this._isAlfenSocketControlReadDpId(id) || this._isAlfenScnReadDpId(id);\n }\n\n _alfenReadVariantKeyForItem(item, unitIdOverride = null) {\n if (!item || !item.dp || !item.src) return '';\n const uid = this._operationUnitId(unitIdOverride ?? item.unitId ?? this._sourceUnitId(item.src));\n const baseAddr = Number(item.baseAddr ?? item.addr);\n const len = Number(item.len ?? item.src.length ?? 1);\n const fc = Number(item.fc ?? item.src.fc ?? 3);\n return `${String(item.dp.id || '')}:uid${uid}:fc${fc}:addr${baseAddr}:len${len}`;\n }\n\n _applyAlfenReadAddressVariant(item) {\n const base = Number(item && item.addr);\n if (!this._isAlfenProfile || !item || !item.dp || !this._isAlfenAdaptiveReadDpId(item.dp.id)) return base;\n const key = this._alfenReadVariantKeyForItem(item);\n const offset = key && this._alfenReadAddressOffsetByKey ? Number(this._alfenReadAddressOffsetByKey.get(key) || 0) : 0;\n return Number.isFinite(base) && Number.isFinite(offset) ? base + offset : base;\n }\n\n _alfenReadWordOrderForItem(item, fallback) {\n if (!this._isAlfenProfile || !item || !item.dp || !item.src) return fallback;\n\n // Alfen's mixed-endian rule applies to multi-register numeric values. STRING/ASCII\n // registers are transmitted in normal, consecutive register order (two ASCII bytes\n // per 16-bit register). Applying the connection-wide LE word order to a five-register\n // Mode-3 string reverses the complete string and moves the first NUL byte to the front,\n // which decodes as an empty value and makes the UI fall back to \"Operative\".\n const dataType = String(item.src.dataType || '').toLowerCase();\n if (dataType === 'string' || dataType === 'ascii') {\n return normalizeWordOrder(item.src.wordOrder || 'be');\n }\n\n if (!this._isAlfenAdaptiveReadDpId(item.dp.id)) return fallback;\n const key = this._alfenReadVariantKeyForItem(item);\n const value = key && this._alfenReadWordOrderByKey ? this._alfenReadWordOrderByKey.get(key) : undefined;\n return value ? normalizeWordOrder(value) : fallback;\n }\n\n _alfenReadByteOrderForItem(item, fallback) {\n if (!this._isAlfenProfile || !item || !item.dp || !item.src) return fallback;\n\n // Alfen STRING/ASCII registers use network byte order inside every 16-bit register.\n // Keep this independent from the connection-wide numeric byte/word order settings.\n const dataType = String(item.src.dataType || '').toLowerCase();\n if (dataType === 'string' || dataType === 'ascii') {\n return normalizeByteOrder(item.src.byteOrder || 'be');\n }\n\n if (!this._isAlfenAdaptiveReadDpId(item.dp.id)) return fallback;\n const key = this._alfenReadVariantKeyForItem(item);\n const value = key && this._alfenReadByteOrderByKey ? this._alfenReadByteOrderByKey.get(key) : undefined;\n return value ? normalizeByteOrder(value) : fallback;\n }\n\n _alfenReadFallbackOffsetsForGroup(g) {\n // No +1/-1 fallback for Alfen ACE. The guide explicitly requires\n // document register - 1 as the Modbus address.\n return [];\n }\n\n _cacheAlfenReadVariantForGroup(g, unitId, offset, wordOrder, byteOrder) {\n if (!this._isAlfenProfile || !g || !Array.isArray(g.items)) return;\n const off = Number(offset);\n if (!Number.isFinite(off)) return;\n for (const item of g.items) {\n if (!item || !item.dp || !this._isAlfenAdaptiveReadDpId(item.dp.id)) continue;\n const key = this._alfenReadVariantKeyForItem(item, unitId);\n if (!key) continue;\n if (this._alfenReadAddressOffsetByKey) {\n if (off === 0) this._alfenReadAddressOffsetByKey.delete(key);\n else this._alfenReadAddressOffsetByKey.set(key, off);\n }\n if (this._alfenReadWordOrderByKey) {\n if (wordOrder) this._alfenReadWordOrderByKey.set(key, normalizeWordOrder(wordOrder));\n else this._alfenReadWordOrderByKey.delete(key);\n }\n if (this._alfenReadByteOrderByKey) {\n if (byteOrder) this._alfenReadByteOrderByKey.set(key, normalizeByteOrder(byteOrder));\n else this._alfenReadByteOrderByKey.delete(key);\n }\n }\n }\n\n _cacheAlfenReadVariantForDatapoint(dp, unitId, offset, wordOrder, byteOrder) {\n if (!this._isAlfenProfile || !dp || !dp.id || !this._isAlfenAdaptiveReadDpId(dp.id)) return;\n const off = Number(offset);\n if (!Number.isFinite(off)) return;\n const src = getReadSource(dp);\n if (!src) return;\n const baseAddr = this._addr(src);\n if (!Number.isFinite(baseAddr)) return;\n const len = Number(src.length || 1);\n const fc = Number(src.fc || 3);\n const item = { dp, src, addr: baseAddr, baseAddr, len, fc, unitId: this._sourceUnitId(src) };\n const key = this._alfenReadVariantKeyForItem(item, unitId);\n if (!key) return;\n if (this._alfenReadAddressOffsetByKey) {\n if (off === 0) this._alfenReadAddressOffsetByKey.delete(key);\n else this._alfenReadAddressOffsetByKey.set(key, off);\n }\n const dt = String(src.dataType || '').toLowerCase();\n const usesMultiwordNumericOrder = Number(len) > 1 && [\n 'int32', 'uint32', 'float32', 'int64', 'uint64', 'float64',\n ].includes(dt);\n if (this._alfenReadWordOrderByKey) {\n if (usesMultiwordNumericOrder && wordOrder) this._alfenReadWordOrderByKey.set(key, normalizeWordOrder(wordOrder));\n else this._alfenReadWordOrderByKey.delete(key);\n }\n if (this._alfenReadByteOrderByKey) {\n if (usesMultiwordNumericOrder && byteOrder) this._alfenReadByteOrderByKey.set(key, normalizeByteOrder(byteOrder));\n else this._alfenReadByteOrderByKey.delete(key);\n }\n }\n\n _cacheAlfenReadVariantForControlBlock(kind, unitId, offset, wordOrder, byteOrder) {\n if (!this._isAlfenProfile || !this.template || !Array.isArray(this.template.datapoints)) return;\n const off = Number(offset);\n if (!Number.isFinite(off)) return;\n const expectedUid = this._operationUnitId(unitId);\n for (const dp of this.template.datapoints) {\n if (!dp || !dp.id) continue;\n const id = String(dp.id);\n const matches = kind === 'socket' ? this._isAlfenSocketControlReadDpId(id) : this._isAlfenScnReadDpId(id);\n if (!matches) continue;\n const src = getReadSource(dp);\n if (!src) continue;\n const srcUid = this._operationUnitId(this._sourceUnitId(src));\n if (srcUid !== expectedUid) continue;\n this._cacheAlfenReadVariantForDatapoint(dp, unitId, off, wordOrder, byteOrder);\n }\n }\n\n async _getDpStateNumber(dpId) {\n if (!dpId) return undefined;\n try {\n const fullId = `${this.adapter.namespace}.devices.${this.device.id}.${String(dpId)}`;\n const st = await this.adapter.getStateAsync(fullId);\n if (!st || st.val === null || st.val === undefined) return undefined;\n const n = Number(st.val);\n return Number.isFinite(n) ? n : undefined;\n } catch (_) {\n return undefined;\n }\n }\n\n async _waitForMinCommandInterval() {\n const min = Number(this.minCommandIntervalMs || 0);\n if (!min || min <= 0) return;\n\n const last = Number(this._lastCommandAt || 0);\n if (!last || last <= 0) return;\n\n const now = Date.now();\n const next = last + min;\n if (now < next) {\n await sleep(next - now);\n }\n }\n\n async _withIoLock(fn, label = 'Modbus operation') {\n // Serialize all Modbus operations per device. This avoids read/write interleaving\n // and also allows us to enforce a minimum interval between commands.\n const run = async () => {\n await this._waitForMinCommandInterval();\n this._lastCommandAt = Date.now();\n try {\n const res = await this._withHardTimeout(\n Promise.resolve().then(fn),\n this.operationTimeoutMs,\n label,\n (err) => {\n if (isTransportError(err)) this._markDisconnected(err);\n }\n );\n // On any successful Modbus operation we reset the failure streak/backoff\n this._failStreak = 0;\n this._nextConnectAt = 0;\n return res;\n } catch (e) {\n if (isTransportError(e)) this._markDisconnected(e);\n throw e;\n }\n };\n\n const p = (this._ioQueue || Promise.resolve())\n .catch(() => {})\n .then(run);\n\n // Keep the queue alive even if the current op fails. The hard-timeout above ensures\n // that a lost Modbus callback cannot keep this queue pending forever.\n this._ioQueue = p.catch(() => {});\n return p;\n }\n\n _getWritePassword() {\n if (!this._writeUnlock) return null;\n const field = (this._writeUnlock.passwordField || 'writePassword').toString();\n const c = this.device?.connection || {};\n const v = c[field];\n if (v !== null && v !== undefined) {\n const s = String(v).trim();\n if (s) return s;\n }\n\n // Template-level default (device specific). This enables \"it just works\" write control\n // for devices that have a fixed default unlock password (e.g. many SolaX models).\n const def = this._writeUnlock.defaultPassword;\n if (def === null || def === undefined) return null;\n const ds = String(def).trim();\n return ds ? ds : null;\n }\n\n async _maybeUnlockForWrite(currentWriteSrc) {\n if (!this._writeUnlock) return;\n\n const pwStr = this._getWritePassword();\n if (!pwStr) return;\n\n // Avoid accidental recursion: if the datapoint we are writing *is* the unlock register itself.\n try {\n if (currentWriteSrc) {\n const cfc = Number(currentWriteSrc.fc);\n const caddr = Number(currentWriteSrc.address);\n if (cfc === Number(this._writeUnlock.fc) && caddr === Number(this._writeUnlock.address)) return;\n }\n } catch (e) {\n // ignore\n }\n\n const now = Date.now();\n const cacheMs = Number(this._writeUnlock.cacheMs || 0);\n if (cacheMs > 0 && this._writeUnlockUntil && now < this._writeUnlockUntil) return;\n\n let pw = parseInt(pwStr, 10);\n if (!Number.isFinite(pw)) pw = 0;\n if (pw < 0) pw = 0;\n\n const fc = Number(this._writeUnlock.fc || 6);\n const addr = Number(this._writeUnlock.address || 0) + this.manualAddressOffset + this.autoAddressOffset;\n\n // Only FC6 and FC16 make sense for unlocking.\n if (fc === 6) {\n await this._mbWriteRegister(addr, pw & 0xFFFF);\n } else if (fc === 16) {\n await this._mbWriteRegisters(addr, [pw & 0xFFFF]);\n } else {\n // Unsupported unlock FC -> ignore (but log)\n this.adapter.log.warn(`[${this.device.id}] writeUnlock configured with unsupported FC=${fc}. Skipping unlock.`);\n return;\n }\n\n if (cacheMs > 0) this._writeUnlockUntil = now + cacheMs;\n this.adapter.log.debug(`[${this.device.id}] Modbus write-unlock OK (FC${fc}@${addr}).`);\n }\n\n async _maybeVerifyWriteComponentId(dp, src, unitId) {\n const spec = src && (src.requireComponentId || src.verifyComponentId || src.componentIdGuard);\n if (!spec || typeof spec !== 'object') return;\n\n const expected = String(spec.expected ?? spec.value ?? '').trim();\n const address = Number(spec.address);\n const length = Number(spec.length ?? 8);\n const fc = Number(spec.fc ?? 3);\n const wo = spec.wordOrder || 'be';\n const bo = spec.byteOrder || 'be';\n const cacheMsRaw = Number(spec.cacheMs ?? 60000);\n const cacheMs = Number.isFinite(cacheMsRaw) && cacheMsRaw >= 0 ? cacheMsRaw : 60000;\n const uid = this._operationUnitId(unitId);\n\n if (!expected || !Number.isInteger(address) || address < 0 || !Number.isInteger(length) || length < 1 || length > 125 || ![3, 4].includes(fc)) {\n const err = new Error(`Invalid requireComponentId configuration for ${dp?.id || 'Modbus datapoint'}`);\n err.code = 'E_MODBUS_COMPONENT_GUARD_CONFIG';\n throw err;\n }\n\n const guardAddress = this._addr({\n address,\n length,\n addressOffsetSetting: spec.addressOffsetSetting,\n });\n if (!Number.isInteger(guardAddress) || guardAddress < 0 || guardAddress + length > 65536) {\n const err = new Error(`Invalid component-ID guard address for ${dp?.id || 'Modbus datapoint'}`);\n err.code = 'E_MODBUS_COMPONENT_GUARD_CONFIG';\n throw err;\n }\n\n const cacheKey = `${uid}|fc${fc}|${guardAddress}|${length}|${expected}`;\n const now = Date.now();\n const validUntil = Number(this._verifiedWriteComponentIds.get(cacheKey) || 0);\n if (cacheMs > 0 && validUntil > now) return;\n\n let regs;\n try {\n regs = await this._readRegisterWords(fc, guardAddress, length, uid);\n } catch (error) {\n const err = new Error(\n `${dp?.id || 'Modbus write'} blocked: component-ID verification at UID${uid} FC${fc}@${guardAddress} ` +\n `failed (${error && error.message ? error.message : error}). Download the current FENECON Modbus list and ` +\n `verify the ctrlBalancing0 register block before writing.`,\n );\n err.code = 'E_MODBUS_COMPONENT_GUARD_READ';\n err.cause = error;\n throw err;\n }\n\n const actual = String(bufferToValue(regsToBuffer(regs, wo, bo), spec.dataType || 'string') ?? '').trim();\n if (actual !== expected) {\n const err = new Error(\n `${dp?.id || 'Modbus write'} blocked: expected component-ID ${JSON.stringify(expected)} at ` +\n `UID${uid} FC${fc}@${guardAddress}, but read ${JSON.stringify(actual || '<empty>')}. ` +\n `FENECON register blocks can move after app updates; download the current Modbus datapoint list before writing.`,\n );\n err.code = 'E_MODBUS_COMPONENT_ID_MISMATCH';\n err.expectedComponentId = expected;\n err.actualComponentId = actual;\n err.componentIdAddress = guardAddress;\n throw err;\n }\n\n if (cacheMs > 0) this._verifiedWriteComponentIds.set(cacheKey, Date.now() + cacheMs);\n try {\n this.adapter.log.debug(\n `[${this.device?.id || 'modbus'}] Component-ID guard accepted ${expected} at UID${uid} FC${fc}@${guardAddress} for ${dp?.id || 'write'}.`,\n );\n } catch (_) {}\n }\n\n _sunSpecSignatureInfo(regs) {\n if (!Array.isArray(regs) || regs.length < 2) return null;\n const r0 = Number(regs[0]) & 0xFFFF;\n const r1 = Number(regs[1]) & 0xFFFF;\n\n // \"SunS\" in two 16-bit registers.\n // Normal (big-endian words, big-endian bytes): 0x5375 0x6E53\n if (r0 === 0x5375 && r1 === 0x6E53) return { wordOrder: 'be', byteOrder: 'be' };\n\n // Some devices swap bytes inside the 16-bit words: 0x7553 0x536E\n if (r0 === 0x7553 && r1 === 0x536E) return { wordOrder: 'be', byteOrder: 'le' };\n\n // Rare: swapped word order (should not happen for SunSpec, but we accept it for robustness)\n if (r0 === 0x6E53 && r1 === 0x5375) return { wordOrder: 'le', byteOrder: 'be' };\n if (r0 === 0x536E && r1 === 0x7553) return { wordOrder: 'le', byteOrder: 'le' };\n\n return null;\n }\n\n async _maybeDiscoverSunSpec() {\n if (!this._autoSunSpec) return false;\n if (this._sunSpecDiscovered) return true;\n\n // Only do discovery once per runtime.\n this._sunSpecDiscovered = true;\n\n // Candidates (kept intentionally small to avoid long connect delays)\n const templateBase = Number.isFinite(this._sunSpecTemplateBase) ? this._sunSpecTemplateBase : 40000;\n\n const baseCandidates = (this._sunSpecScanBases && this._sunSpecScanBases.length)\n ? this._sunSpecScanBases\n : [templateBase, templateBase - 1, 0, 1];\n\n const unitCandidates = [];\n const pushUid = (v) => {\n const n = Number(v);\n if (!Number.isFinite(n)) return;\n if (n < 0 || n > 247) return;\n if (!unitCandidates.includes(n)) unitCandidates.push(n);\n };\n pushUid(this.manualUnitId);\n\n // SMA note (field reality): some SMA devices expose SunSpec on a derived unitId.\n // Common case: SunSpec Unit-ID = (configured SMA Modbus Unit-ID) + 123.\n // Example: SMA unitId=3 -> SunSpec unitId=126.\n pushUid(this.manualUnitId + 123);\n // Common SMA / SunSpec unit IDs seen in the field\n pushUid(1);\n pushUid(3);\n pushUid(126);\n if (this._sunSpecScanUnitIds && this._sunSpecScanUnitIds.length) {\n for (const u of this._sunSpecScanUnitIds) pushUid(u);\n }\n\n const fcCandidates = (this._sunSpecScanFcs && this._sunSpecScanFcs.length)\n ? this._sunSpecScanFcs\n : [3, 4];\n\n const originalTimeout = this.timeoutMs;\n const discoveryTimeout = Math.min(1000, Math.max(300, originalTimeout));\n try {\n // Temporarily tighten timeout for discovery probes\n if (this.protocol === 'modbusTcp' && this.client && typeof this.client.setTimeout === 'function') {\n try { this.client.setTimeout(discoveryTimeout); } catch (_) {}\n }\n\n for (const uid of unitCandidates) {\n this._setUnitId(uid);\n\n for (const fc of fcCandidates) {\n for (const base of baseCandidates) {\n const b = Number(base);\n if (!Number.isFinite(b)) continue;\n const testAddr = b + this.manualAddressOffset;\n if (testAddr < 0 || testAddr > 65535) continue;\n\n try {\n let regs;\n if (fc === 3) {\n regs = (await this._mbReadHoldingRegisters(testAddr, 2)).data || [];\n } else if (fc === 4) {\n regs = (await this._mbReadInputRegisters(testAddr, 2)).data || [];\n } else {\n continue;\n }\n\n const sig = this._sunSpecSignatureInfo(regs);\n if (sig) {\n // Compute only the *additional* offset beyond the manual offset.\n const autoOff = b - templateBase - this.manualAddressOffset;\n this.autoAddressOffset = autoOff;\n this.autoUnitId = uid;\n this._sunSpecFc = fc;\n this._sunSpecFoundBase = b;\n // Reset model scan cache because base/unit may have changed\n this._sunSpecModelsScanned = false;\n this._sunSpecModelsById = new Map();\n\n // SunSpec endian handling:\n // The SunSpec signature tells us whether bytes/words are swapped on this device.\n // We enforce the detected endian regardless of the user/device connection settings\n // because wrong byte/word order will completely break SF scaling (e.g. values like 2.4e+260).\n const prevWo = this.wordOrder;\n const prevBo = this.byteOrder;\n if (sig && sig.wordOrder) this.wordOrder = sig.wordOrder;\n if (sig && sig.byteOrder) this.byteOrder = sig.byteOrder;\n\n const endianNote = (prevWo !== this.wordOrder || prevBo !== this.byteOrder)\n ? ` Endian: wordOrder=${this.wordOrder}, byteOrder=${this.byteOrder} (was wordOrder=${prevWo}, byteOrder=${prevBo}).`\n : ` Endian: wordOrder=${this.wordOrder}, byteOrder=${this.byteOrder}.`;\n\n this.adapter.log.info(\n `[${this.device.id}] SunSpec discovery: found 'SunS' at base=${b} (FC${fc}, unitId=${uid}). ` +\n `Applying autoAddressOffset=${autoOff} (manualAddressOffset=${this.manualAddressOffset}).${endianNote}`\n );\n return true;\n }\n } catch (e) {\n if (isReadOperationBoundaryError(e)) throw e;\n // Ignore probe errors and continue scanning.\n }\n }\n }\n }\n\n this.adapter.log.debug(\n `[${this.device.id}] SunSpec discovery: signature not found. ` +\n `Keeping unitId=${this.unitId} and addressOffset(manual)=${this.manualAddressOffset}.`\n );\n return false;\n } finally {\n // Restore timeout\n if (this.protocol === 'modbusTcp' && this.client && typeof this.client.setTimeout === 'function') {\n try { this.client.setTimeout(originalTimeout); } catch (_) {}\n }\n }\n }\n\n\n\n async _maybeScanSunSpecModels() {\n if (!this._autoSunSpec) return false;\n if (this._sunSpecModelsScanned) return true;\n\n // Ensure discovery has run so we know the correct unitId/base/fc/endian.\n try {\n await this._maybeDiscoverSunSpec();\n } catch (error) {\n if (isReadOperationBoundaryError(error)) throw error;\n // ignore\n }\n\n const fc = (this._sunSpecFc === 4) ? 4 : 3;\n const templateBase = Number(this._sunSpecTemplateBase ?? 40000);\n const base = templateBase + this.manualAddressOffset + this.autoAddressOffset;\n\n if (!Number.isFinite(base) || base < 0 || base > 65535) return false;\n\n const readRegs = async (addr, len) => {\n if (fc === 4) return (await this._mbReadInputRegisters(addr, len)).data || [];\n return (await this._mbReadHoldingRegisters(addr, len)).data || [];\n };\n\n const modelsById = new Map();\n\n // Model blocks start right after the 2-register \"SunS\" signature.\n // Each model is:\n // ID (uint16), L (uint16), <L registers payload>\n // End of map is ID=0xFFFF, L=0.\n let off = 2;\n const maxModels = 200;\n const maxOff = 20000;\n\n for (let i = 0; i < maxModels && off < maxOff; i++) {\n let hdr;\n try {\n hdr = await readRegs(base + off, 2);\n } catch (e) {\n if (isReadOperationBoundaryError(e)) throw e;\n break;\n }\n\n if (!Array.isArray(hdr) || hdr.length < 2) break;\n const did = Number(hdr[0]) & 0xFFFF;\n const len = Number(hdr[1]) & 0xFFFF;\n\n if (did === 0xFFFF) break;\n if (did === 0) break;\n\n if (!modelsById.has(did)) modelsById.set(did, []);\n modelsById.get(did).push({ offset: off, len });\n\n // Advance to next model header\n off += 2 + len;\n }\n\n this._sunSpecModelsById = modelsById;\n this._sunSpecModelsScanned = true;\n\n try {\n const ids = Array.from(modelsById.keys()).sort((a, b) => a - b);\n this.adapter.log.debug(`[${this.device.id}] SunSpec model scan OK (${ids.length}): ${ids.join(', ')}`);\n } catch (_) {}\n\n return true;\n }\n\n async _mbReadCoils(start, len, unitIdOverride = null) {\n return await this._withIoLock(async () => {\n const uid = this._operationUnitId(unitIdOverride);\n if (this.protocol === 'modbusRtu') return await this.rtuBus.readCoils(uid, this.timeoutMs, start, len);\n if (this.protocol === 'modbusAscii') return await this.asciiBus.readCoils(uid, this.timeoutMs, start, len);\n if (!this.client) {\n const err = new Error('Port Not Open');\n err.code = 'ERR_SOCKET_CLOSED';\n throw err;\n }\n this._setTcpRequestUnitId(uid);\n return await this.client.readCoils(start, len);\n });\n }\n\n async _mbReadDiscreteInputs(start, len, unitIdOverride = null) {\n return await this._withIoLock(async () => {\n const uid = this._operationUnitId(unitIdOverride);\n if (this.protocol === 'modbusRtu') return await this.rtuBus.readDiscreteInputs(uid, this.timeoutMs, start, len);\n if (this.protocol === 'modbusAscii') return await this.asciiBus.readDiscreteInputs(uid, this.timeoutMs, start, len);\n if (!this.client) {\n const err = new Error('Port Not Open');\n err.code = 'ERR_SOCKET_CLOSED';\n throw err;\n }\n this._setTcpRequestUnitId(uid);\n return await this.client.readDiscreteInputs(start, len);\n });\n }\n\n async _mbReadHoldingRegisters(start, len, unitIdOverride = null) {\n return await this._withIoLock(async () => {\n const uid = this._operationUnitId(unitIdOverride);\n if (this.protocol === 'modbusRtu') return await this.rtuBus.readHoldingRegisters(uid, this.timeoutMs, start, len);\n if (this.protocol === 'modbusAscii') return await this.asciiBus.readHoldingRegisters(uid, this.timeoutMs, start, len);\n if (!this.client) {\n const err = new Error('Port Not Open');\n err.code = 'ERR_SOCKET_CLOSED';\n throw err;\n }\n this._setTcpRequestUnitId(uid);\n return await this.client.readHoldingRegisters(start, len);\n });\n }\n\n async _mbReadInputRegisters(start, len, unitIdOverride = null) {\n return await this._withIoLock(async () => {\n const uid = this._operationUnitId(unitIdOverride);\n if (this.protocol === 'modbusRtu') return await this.rtuBus.readInputRegisters(uid, this.timeoutMs, start, len);\n if (this.protocol === 'modbusAscii') return await this.asciiBus.readInputRegisters(uid, this.timeoutMs, start, len);\n if (!this.client) {\n const err = new Error('Port Not Open');\n err.code = 'ERR_SOCKET_CLOSED';\n throw err;\n }\n this._setTcpRequestUnitId(uid);\n return await this.client.readInputRegisters(start, len);\n });\n }\n\n async _readRegisterWords(fc, start, len, unitId) {\n const response = fc === 3\n ? await this._mbReadHoldingRegisters(start, len, unitId)\n : await this._mbReadInputRegisters(start, len, unitId);\n const regs = response?.data;\n let invalid = !Array.isArray(regs) || regs.length !== len;\n // modbus-serial exposes the payload buffer when available. An odd byte\n // count can otherwise yield the expected word count despite a short payload.\n if (Buffer.isBuffer(response?.buffer) && response.buffer.length !== len * 2) invalid = true;\n if (!invalid) {\n for (let i = 0; i < len; i++) {\n // Array.every/some skip sparse entries; missing words must never be\n // coerced to zero by regsToBuffer's bitwise conversion.\n if (!Object.prototype.hasOwnProperty.call(regs, i) || !Number.isInteger(regs[i]) || regs[i] < 0 || regs[i] > 65535) {\n invalid = true;\n break;\n }\n }\n }\n if (invalid) {\n const error = new Error(`Invalid Modbus FC${fc} response at UID${this._operationUnitId(unitId)} ${start}: expected exactly ${len} unsigned 16-bit registers`);\n error.code = 'E_MODBUS_READ_RESPONSE';\n throw error;\n }\n return regs;\n }\n\n async _mbWriteCoil(addr, value, unitIdOverride = null) {\n return await this._withIoLock(async () => {\n const uid = this._operationUnitId(unitIdOverride);\n if (this.protocol === 'modbusRtu') return await this.rtuBus.writeCoil(uid, this.timeoutMs, addr, value);\n if (this.protocol === 'modbusAscii') return await this.asciiBus.writeCoil(uid, this.timeoutMs, addr, value);\n if (!this.client) {\n const err = new Error('Port Not Open');\n err.code = 'ERR_SOCKET_CLOSED';\n throw err;\n }\n this._setTcpRequestUnitId(uid);\n return await this.client.writeCoil(addr, value);\n });\n }\n\n async _mbWriteCoils(addr, values, unitIdOverride = null) {\n return await this._withIoLock(async () => {\n const uid = this._operationUnitId(unitIdOverride);\n if (this.protocol === 'modbusRtu') return await this.rtuBus.writeCoils(uid, this.timeoutMs, addr, values);\n if (this.protocol === 'modbusAscii') return await this.asciiBus.writeCoils(uid, this.timeoutMs, addr, values);\n if (!this.client) {\n const err = new Error('Port Not Open');\n err.code = 'ERR_SOCKET_CLOSED';\n throw err;\n }\n this._setTcpRequestUnitId(uid);\n return await this.client.writeCoils(addr, values);\n });\n }\n\n async _mbWriteRegister(addr, value, unitIdOverride = null) {\n return await this._withIoLock(async () => {\n const uid = this._operationUnitId(unitIdOverride);\n if (this.protocol === 'modbusRtu') return await this.rtuBus.writeRegister(uid, this.timeoutMs, addr, value);\n if (this.protocol === 'modbusAscii') return await this.asciiBus.writeRegister(uid, this.timeoutMs, addr, value);\n if (!this.client) {\n const err = new Error('Port Not Open');\n err.code = 'ERR_SOCKET_CLOSED';\n throw err;\n }\n this._setTcpRequestUnitId(uid);\n return await this.client.writeRegister(addr, value);\n });\n }\n\n async _mbWriteRegisters(addr, values, unitIdOverride = null) {\n return await this._withIoLock(async () => {\n const uid = this._operationUnitId(unitIdOverride);\n if (this.protocol === 'modbusRtu') return await this.rtuBus.writeRegisters(uid, this.timeoutMs, addr, values);\n if (this.protocol === 'modbusAscii') return await this.asciiBus.writeRegisters(uid, this.timeoutMs, addr, values);\n if (!this.client) {\n const err = new Error('Port Not Open');\n err.code = 'ERR_SOCKET_CLOSED';\n throw err;\n }\n this._setTcpRequestUnitId(uid);\n return await this.client.writeRegisters(addr, values);\n });\n }\n\n // NOTE: _addr() has been moved up to include manual+auto offsets.\n\n _shouldInvert(settingKey) {\n if (!settingKey) return false;\n // allow either device.<key> or device.settings.<key>\n const direct = this.device?.[settingKey];\n if (typeof direct === 'boolean') return direct;\n const nested = this.device?.settings?.[settingKey];\n if (typeof nested === 'boolean') return nested;\n return false;\n }\n\n\n_getScaleFactor(src) {\n if (!src) return 0;\n\n // The supplied V10.03 table specifies 100 Wh/tick for both counters. A\n // firmware-specific resolution must be selected explicitly, per counter.\n if (this._depowerV1003 && ['session', 'total'].includes(src.depowerEnergyCounter)) {\n const key = src.depowerEnergyCounter === 'session'\n ? 'depowerSessionEnergyWhPerTick' : 'depowerTotalEnergyWhPerTick';\n const configured = this.device?.connection?.[key];\n if (configured !== undefined && configured !== null && configured !== '') {\n return Math.log10(Number(configured)) - 3; // internal datapoints remain kWh\n }\n }\n\n // Dynamic scale factor via reference (e.g. SunSpec <X>_SF)\n if (src.scaleFactorRef) {\n const key = String(src.scaleFactorRef);\n const cached = this._sfCache.get(key);\n const n = Number(cached);\n\n // SunSpec uses 0x8000 (-32768) as \"not implemented\" for int16\n if (!Number.isNaN(n) && n !== -32768) {\n // Sanity guard: scale factors are small exponents. Huge values are almost always\n // a byte/word-order or address-offset issue and will explode numbers (e.g. 2.4e+260).\n if (Math.abs(n) > 20) {\n const now = Date.now();\n const until = this._sfWarnedUntil ? (Number(this._sfWarnedUntil.get(key)) || 0) : 0;\n if (!until || now > until) {\n try {\n if (this._sfWarnedUntil) this._sfWarnedUntil.set(key, now + 60000); // 60s throttle per SF key\n } catch (_) {}\n this.adapter.log.warn(\n `[${this.device.id}] Suspicious scale factor ${key}=${n}. Ignoring scaling (SF=0). ` +\n `Check Modbus Byte-/Wortreihenfolge and address offset.`\n );\n }\n return 0;\n }\n return n;\n }\n }\n\n const n = Number(src.scaleFactor || 0);\n return Number.isNaN(n) ? 0 : n;\n}\n\n _applyTransforms(value, src) {\n if (typeof value !== 'number') return value;\n if (Number.isNaN(value)) {\n // Optionally map IEEE NaN to null as well (useful for meters that export NaN for\n // non-supported values). Enabled per datapoint via `nanToNull`.\n if (src && (src.nanToNull === true || src.nanNull === true || src.nanToUndefined === true)) return null;\n return value;\n }\n\n let v = value;\n\n const parseIntMaybeHex = (x) => {\n if (x === null || x === undefined) return undefined;\n if (typeof x === 'number' && Number.isFinite(x)) return x;\n if (typeof x === 'string') {\n const s = x.trim().toLowerCase();\n if (s === '') return undefined;\n if (s.startsWith('0x')) {\n const n = parseInt(s, 16);\n return Number.isFinite(n) ? n : undefined;\n }\n const n = Number(s);\n return Number.isFinite(n) ? n : undefined;\n }\n return undefined;\n };\n\n // Optional explicit boolean value mapping. Many vendors use non-0/1 codes\n // for switches (e.g. Sungrow 0xAA=enable, 0x55=disable).\n const trueValue = parseIntMaybeHex(src && (src.trueValue ?? src.onValue ?? src.enableValue ?? src.valueTrue));\n const falseValue = parseIntMaybeHex(src && (src.falseValue ?? src.offValue ?? src.disableValue ?? src.valueFalse));\n\n if (trueValue !== undefined || falseValue !== undefined) {\n if (trueValue !== undefined && v === trueValue) return true;\n if (falseValue !== undefined && v === falseValue) return false;\n if (src && (src.toBoolean === true || src.boolean === true)) return v !== 0;\n }\n\n // Optional NaN/sentinel handling (device specific).\n // Many Modbus profiles (including SMA) use fixed sentinel values to indicate \"NaN\" / \"not implemented\".\n // We only apply this conversion when explicitly enabled per datapoint, to avoid breaking other devices.\n //\n // Usage:\n // source: { nanToNull: true } -> use default sentinel per dataType\n // source: { nanValue: 0x80000000 } -> map this value to null\n const nanValue = parseIntMaybeHex(src && (src.nanValue ?? src.nan));\n if (nanValue !== undefined && v === nanValue) return null;\n\n if (src && (src.nanToNull === true || src.nanNull === true || src.nanToUndefined === true)) {\n const dt = (src.dataType || '').toString().toLowerCase();\n\n // Defaults match SMA Modbus TI (S16=0x8000, S32=0x80000000, U16=0xFFFF, U32=0xFFFFFFFF)\n // and common Modbus conventions.\n if ((dt === 'int16' || dt === 's16') && v === -32768) return null;\n if ((dt === 'uint16' || dt === 'u16') && v === 65535) return null;\n if ((dt === 'int32' || dt === 's32') && v === -2147483648) return null;\n if ((dt === 'uint32' || dt === 'u32') && v === 4294967295) return null;\n }\n\n // Optional bit extraction (useful for packed status registers).\n // Applied BEFORE scaling and sign transforms.\n const bitShift = parseIntMaybeHex(src && src.bitShift);\n const bitMask = parseIntMaybeHex(src && src.bitMask);\n\n if ((bitShift !== undefined && bitShift !== 0) || bitMask !== undefined) {\n // Ensure integer for bit ops. We intentionally use unsigned operations by default.\n const vi = Math.trunc(v);\n let vv = vi;\n\n if (bitShift !== undefined && bitShift !== 0) {\n const sh = Math.trunc(bitShift);\n if (sh > 0) {\n if (src && src.bitShiftSigned === true) {\n vv = (vv >> sh);\n } else {\n vv = (vv >>> sh);\n }\n } else if (sh < 0) {\n // Negative shift means left shift\n const lsh = -sh;\n vv = (vv << lsh);\n }\n }\n\n if (bitMask !== undefined) {\n const mask = Math.trunc(bitMask);\n vv = (vv & mask);\n }\n\n v = vv;\n }\n\n // scaleFactor is applied on read direction (Element -> Channel)\n const sf = this._getScaleFactor(src);\n if (sf) v = applyScale(v, sf);\n\n if (src.invert === true) v = -v;\n if (src.invertIfSetting && this._shouldInvert(src.invertIfSetting)) v = -v;\n\n if (src.keepPositive === true) v = Math.max(0, v);\n if (src.keepNegativeAndInvert === true) v = v < 0 ? (-v) : 0;\n\n if (src.toBoolean === true || src.boolean === true) {\n if (src.trueWhenZero === true || src.booleanWhenZero === true) {\n return v === 0;\n }\n return v !== 0;\n }\n\n return v;\n }\n\n\nasync readDatapoints(datapoints) {\n if (this._busy) {\n const age = Date.now() - Number(this._busySince || 0);\n const maxBusy = Math.max(Number(this.operationTimeoutMs || 0) * 2, Number(this.timeoutMs || 0) * 3, 10000);\n if (this._busySince && age > maxBusy) {\n const err = this._makeTimeoutError('Modbus poll busy guard', maxBusy, 'E_MODBUS_BUSY_STALE');\n this.adapter.log.warn(`[${this.device?.id || 'modbus'}] Modbus poll was busy for ${age} ms; forcing reconnect and clearing IO queue.`);\n this._busy = false;\n this._busySince = 0;\n this._markDisconnected(err);\n } else {\n return {}; // skip overlapping polls\n }\n }\n this._busy = true;\n this._busySince = Date.now();\n\n const out = {};\n\n // Keep numeric raw values separate so we can apply dynamic scale factors after all reads.\n const numRawById = {};\n const srcById = {};\n\n let optionalFailureCount = 0;\n let skippedReadGroupCount = 0;\n let lastOptionalReadError = null;\n\n const groupKey = (fc, g, unitId) => `${this._operationUnitId(unitId)}:${Number(fc)}:${Number(g.start)}:${Number(g.end)}`;\n const groupHasRequiredDp = (g) => {\n if (!this.requiredReadDpIds || !this.requiredReadDpIds.size) return false;\n return (g.items || []).some(item => item && item.dp && this.requiredReadDpIds.has(String(item.dp.id)));\n };\n const warnOptionalGroupFailure = (fc, g, e, unitId) => {\n const key = groupKey(fc, g, unitId);\n const now = Date.now();\n const nextWarnAt = this._readGroupWarnUntil.get(key) || 0;\n if (now < nextWarnAt) return;\n this._readGroupWarnUntil.set(key, now + 60000);\n const msg = (e && e.message) ? e.message : String(e);\n const ids = (g.items || []).map(item => item && item.dp ? item.dp.id : '').filter(Boolean).slice(0, 8).join(', ');\n const uid = this._operationUnitId(unitId);\n const line = `[${this.device?.id || 'modbus'}] Optional Modbus read group failed and will be skipped temporarily: UID${uid} FC${fc} ${g.start}-${g.end}${ids ? ` (${ids}${(g.items || []).length > 8 ? ', ...' : ''})` : ''}: ${msg}`;\n const lvl = String(this.optionalReadErrorLogLevel || 'warn').toLowerCase();\n if (lvl === 'silent' || lvl === 'none' || lvl === 'off') return;\n if (lvl === 'debug') this.adapter.log.debug(line);\n else if (lvl === 'info') this.adapter.log.info(line);\n else this.adapter.log.warn(line);\n };\n\n const groupFallbackOffsets = (g) => {\n const alfenOffsets = this._alfenReadFallbackOffsetsForGroup(g);\n if (alfenOffsets && alfenOffsets.length) return alfenOffsets;\n const items = Array.isArray(g?.items) ? g.items : [];\n if (!items.length) return [];\n let common = null;\n for (const item of items) {\n const offsets = this._addressFallbackOffsets(item && item.src);\n if (!offsets.length) return [];\n if (common === null) {\n common = offsets.slice();\n } else {\n common = common.filter(v => offsets.includes(v));\n }\n if (!common.length) return [];\n }\n return common || [];\n };\n\n const shouldSkipGroup = (fc, g, unitId) => {\n // A critical live value must be retried on the next poll, including when\n // an older split-read failure left an entry in the optional skip cache.\n if (groupHasRequiredDp(g)) {\n this._readGroupSkipUntil.delete(groupKey(fc, g, unitId));\n return false;\n }\n if (!(this.continueOnReadError || this.softIllegalAddressReads) || !this.skipFailedReadGroupsMs) return false;\n const until = this._readGroupSkipUntil.get(groupKey(fc, g, unitId)) || 0;\n return until > Date.now();\n };\n\n const shouldForceSplitGroup = (fc, g, unitId) => {\n if (!this.adaptiveReadSplit || !this.splitFailedReadGroupsMs) return false;\n if (!g || !Array.isArray(g.items) || g.items.length <= 1) return false;\n const until = this._readGroupForceSplitUntil.get(groupKey(fc, g, unitId)) || 0;\n return until > Date.now();\n };\n\n const handleGroupReadError = async (fc, g, e, unitId) => {\n if (isReadOperationBoundaryError(e)) throw e;\n const isRequired = groupHasRequiredDp(g);\n\n if (isTransportError(e)) {\n this._markDisconnected(e);\n // Reset the TCP/serial handle so the next command starts with a clean session.\n try { await this.disconnect(); } catch (_) {}\n\n // Only reconnect inside the same poll when the failed group is optional and may be skipped.\n // For required live groups we throw immediately; DeviceRuntime will mark the device offline\n // and the next scheduled poll performs a clean reconnect. This avoids reconnect-then-close\n // races after a required timeout.\n if (this.continueOnReadError && !isRequired) {\n try { await this.ensureConnected(); } catch (_) {}\n }\n }\n\n const canSoftSkip = this.continueOnReadError || (this.softIllegalAddressReads && isModbusIllegalAddressOrValue(e) && !isRequired);\n if (!canSoftSkip || isRequired) {\n throw e;\n }\n\n if (this._isAlfenProfile && isModbusIllegalAddressOrValue(e)) {\n try {\n const ids = (g.items || []).map(item => item && item.dp ? String(item.dp.id || '') : '').filter(Boolean);\n if (ids.some(id => this._isAlfenSocketControlReadDpId(id))) this._markAlfenControlUnsupported('socket', e && e.message ? e.message : String(e));\n if (ids.some(id => this._isAlfenScnReadDpId(id))) this._markAlfenControlUnsupported('scn', e && e.message ? e.message : String(e));\n } catch (_) {}\n }\n\n optionalFailureCount += 1;\n lastOptionalReadError = e;\n if (this.skipFailedReadGroupsMs > 0) {\n this._readGroupSkipUntil.set(groupKey(fc, g, unitId), Date.now() + this.skipFailedReadGroupsMs);\n }\n warnOptionalGroupFailure(fc, g, e, unitId);\n return null;\n };\n\n const noteGroupForcedSplit = (fc, g, unitId, reason) => {\n if (!this.adaptiveReadSplit || !g || !Array.isArray(g.items) || g.items.length <= 1) return;\n const key = groupKey(fc, g, unitId);\n const now = Date.now();\n if (this.splitFailedReadGroupsMs > 0) {\n this._readGroupForceSplitUntil.set(key, now + this.splitFailedReadGroupsMs);\n }\n const nextWarnAt = this._readGroupSplitWarnUntil.get(key) || 0;\n if (now < nextWarnAt) return;\n this._readGroupSplitWarnUntil.set(key, now + 300000);\n const ids = (g.items || []).map(item => item && item.dp ? item.dp.id : '').filter(Boolean).slice(0, 8).join(', ');\n const line = `[${this.device?.id || 'modbus'}] Modbus read group UID${this._operationUnitId(unitId)} FC${fc} ${g.start}-${g.end}${ids ? ` (${ids}${(g.items || []).length > 8 ? ', ...' : ''})` : ''} will be split into per-datapoint reads temporarily${reason ? `: ${reason}` : ''}`;\n try { this.adapter.log.info(line); } catch (_) {}\n };\n\n const storeRegisterItemValue = (item, regs, groupStart) => {\n const dp = item.dp;\n const src = item.src;\n const off = Number(item.addr) - Number(groupStart);\n const slice = (regs || []).slice(off, off + Number(src.length || 1));\n if (slice.length < Number(src.length || 1)) return false;\n\n const wo = this._alfenReadWordOrderForItem(item, src.wordOrder || this.wordOrder);\n const bo = this._alfenReadByteOrderForItem(item, src.byteOrder || this.byteOrder);\n const buf = regsToBuffer(slice, wo, bo);\n let raw = bufferToValue(buf, src.dataType);\n\n if (typeof raw === 'bigint') {\n const dt = String(src.dataType || '').toLowerCase();\n const wantsNull = !!(src.nanToNull === true || src.nanNull === true || src.nanToUndefined === true);\n\n if (wantsNull && dt === 'uint64' && raw === 0xFFFFFFFFFFFFFFFFn) {\n out[dp.id] = null;\n return true;\n }\n\n const conv = bigIntToNumberOrString(raw);\n if (typeof conv === 'string') {\n if (src.bigIntToNullOnOverflow === true || src.uint64OverflowToNull === true) {\n out[dp.id] = null;\n return true;\n }\n out[dp.id] = conv;\n return true;\n }\n raw = conv;\n }\n\n if (typeof raw === 'boolean') {\n out[dp.id] = raw;\n return true;\n }\n\n if (typeof raw === 'string') {\n out[dp.id] = raw;\n return true;\n }\n\n const n = Number(raw);\n const dataType = String(src.dataType || '').toLowerCase();\n if (Number.isNaN(raw) && (dataType === 'float32' || dataType === 'float64') &&\n (src.nanToNull === true || src.nanNull === true || src.nanToUndefined === true)) {\n // The complete uint16 response was validated before decoding. This is an\n // actual IEEE NaN, not a missing word or malformed transport response.\n out[dp.id] = null;\n return true;\n }\n if (!Number.isNaN(n)) {\n numRawById[dp.id] = n;\n srcById[dp.id] = src;\n return true;\n }\n return false;\n };\n\n const readRegisterGroupRaw = async (fc, start, len, unitId) => {\n return this._readRegisterWords(fc, start, len, unitId);\n };\n\n const recoverRegisterGroupBySplit = async (fc, g, unitId, originalError) => {\n if (!this.adaptiveReadSplit || !g || !Array.isArray(g.items) || g.items.length <= 1) return false;\n\n const originalMsg = originalError && originalError.message ? originalError.message : String(originalError || 'read failed');\n noteGroupForcedSplit(fc, g, unitId, originalMsg);\n\n let success = 0;\n let requiredFailure = null;\n let lastErr = null;\n\n for (const item of (g.items || [])) {\n if (!item || !item.dp || !item.src) continue;\n const ig = { start: item.addr, end: item.end, items: [item] };\n if (shouldSkipGroup(fc, ig, unitId)) { skippedReadGroupCount += 1; continue; }\n try {\n const regs = await readRegisterGroupRaw(fc, item.addr, Number(item.len || item.src.length || 1), unitId);\n if (storeRegisterItemValue(item, regs, item.addr)) success += 1;\n } catch (e) {\n if (isReadOperationBoundaryError(e)) throw e;\n lastErr = e;\n if (groupHasRequiredDp(ig)) {\n requiredFailure = e;\n this._readGroupSkipUntil.delete(groupKey(fc, ig, unitId));\n continue;\n }\n optionalFailureCount += 1;\n lastOptionalReadError = e;\n if (this.skipFailedReadGroupsMs > 0) {\n this._readGroupSkipUntil.set(groupKey(fc, ig, unitId), Date.now() + this.skipFailedReadGroupsMs);\n }\n warnOptionalGroupFailure(fc, ig, e, unitId);\n }\n }\n\n if (requiredFailure) throw requiredFailure;\n if (success > 0) return true;\n if (lastErr && !this.continueOnReadError && !this.softIllegalAddressReads) throw lastErr;\n return false;\n };\n\n try {\n await this.ensureConnected();\n\n // SunSpec: if a template uses SunSpec model addressing we need the model map (ID -> start offset).\n // We scan the model chain once (cheap) and then resolve absolute addresses per datapoint.\n const needsSunSpec = (datapoints || []).some(dp => {\n const s = getReadSource(dp);\n return s && s.sunspecModel !== undefined && s.sunspecModel !== null;\n });\n if (needsSunSpec) {\n try { await this._maybeScanSunSpecModels(); } catch (error) { if (isReadOperationBoundaryError(error)) throw error; }\n }\n\n const readItems = (datapoints || []).map(dp => {\n const src = getReadSource(dp);\n if (!src) return null;\n let fc = Number(src.fc);\n // SunSpec templates may auto-detect whether registers are exposed via FC3 or FC4.\n if ((src.sunspecModel !== undefined && src.sunspecModel !== null) && (this._sunSpecFc === 3 || this._sunSpecFc === 4)) {\n fc = this._sunSpecFc;\n }\n if (![1, 2, 3, 4].includes(fc)) return null;\n const baseAddr = this._addr(src);\n // SunSpec models can be optional; if a referenced model does not exist,\n // _addr() returns NaN (for address=0). Skip those datapoints gracefully.\n if (!Number.isFinite(baseAddr)) return null;\n const len = Number(src.length || 1);\n const unitId = this._sourceUnitId(src);\n const addr = this._applyAlfenReadAddressVariant({ dp, src, addr: baseAddr, baseAddr, len, fc, unitId });\n return { dp, src, addr, baseAddr, len, fc, unitId };\n }).filter(Boolean);\n\n // Collect all referenced scale factor datapoints (e.g. <X>_SF)\n const scaleFactorRefs = new Set();\n for (const it of readItems) {\n if (it?.src?.scaleFactorRef) scaleFactorRefs.add(String(it.src.scaleFactorRef));\n }\n\n const byBus = new Map();\n for (const it of readItems) {\n const fc = Number(it.fc);\n const unitId = this._operationUnitId(it.unitId);\n const key = `${unitId}:${fc}`;\n if (!byBus.has(key)) byBus.set(key, { fc, unitId, items: [] });\n byBus.get(key).items.push(it);\n }\n\n for (const { fc, unitId, items } of byBus.values()) {\n if (fc === 1) {\n // Coils\n const groups = buildGroups(items, 2000);\n for (const g of groups) {\n if (shouldSkipGroup(fc, g, unitId)) { skippedReadGroupCount += 1; continue; }\n const len = g.end - g.start + 1;\n let res;\n try {\n res = await this._mbReadCoils(g.start, len, unitId);\n } catch (e) {\n res = await handleGroupReadError(fc, g, e, unitId);\n if (!res) continue;\n }\n const bits = res.data || [];\n for (const item of g.items) {\n const off = item.addr - g.start;\n out[item.dp.id] = !!bits[off];\n }\n }\n continue;\n }\n\n if (fc === 2) {\n // Discrete inputs\n const groups = buildGroups(items, 2000);\n for (const g of groups) {\n if (shouldSkipGroup(fc, g, unitId)) { skippedReadGroupCount += 1; continue; }\n const len = g.end - g.start + 1;\n let res;\n try {\n res = await this._mbReadDiscreteInputs(g.start, len, unitId);\n } catch (e) {\n res = await handleGroupReadError(fc, g, e, unitId);\n if (!res) continue;\n }\n const bits = res.data || [];\n for (const item of g.items) {\n const off = item.addr - g.start;\n out[item.dp.id] = !!bits[off];\n }\n }\n continue;\n }\n\n // Registers\n const groups = buildGroups(items, this.maxReadRegs, {\n allowGaps: !this.strictContiguousReads,\n isolateItems: this.isolateReadDatapoints,\n });\n for (const g of groups) {\n if (shouldSkipGroup(fc, g, unitId)) { skippedReadGroupCount += 1; continue; }\n const len = g.end - g.start + 1;\n\n if (shouldForceSplitGroup(fc, g, unitId)) {\n const recovered = await recoverRegisterGroupBySplit(fc, g, unitId, new Error('cached split mode'));\n if (recovered) continue;\n }\n\n let regs;\n try {\n regs = await readRegisterGroupRaw(fc, g.start, len, unitId);\n } catch (e) {\n if (isReadOperationBoundaryError(e)) throw e;\n let fallbackReadOk = false;\n if (isModbusIllegalAddressOrValue(e)) {\n for (const off of groupFallbackOffsets(g)) {\n const fbStart = Number(g.start) + Number(off);\n if (!Number.isFinite(fbStart) || fbStart < 0) continue;\n try {\n regs = await readRegisterGroupRaw(fc, fbStart, len, unitId);\n fallbackReadOk = true;\n this._cacheAlfenReadVariantForGroup(g, unitId, off);\n break;\n } catch (fallbackError) {\n if (isReadOperationBoundaryError(fallbackError)) throw fallbackError;\n // Try the next explicitly configured fallback offset, if any.\n }\n }\n }\n if (!fallbackReadOk) {\n if (isModbusIllegalAddressOrValue(e)) {\n const recovered = await recoverRegisterGroupBySplit(fc, g, unitId, e);\n if (recovered) continue;\n }\n const res = await handleGroupReadError(fc, g, e, unitId);\n if (!res) continue;\n regs = res.data || [];\n }\n }\n\n for (const item of g.items) {\n storeRegisterItemValue(item, regs, g.start);\n }\n }\n }\n\n // If every requested group failed or was skipped, surface the last failure so the\n // device state still reflects a real communication problem.\n if (Object.keys(out).length === 0 && Object.keys(numRawById).length === 0 && (optionalFailureCount > 0 || skippedReadGroupCount > 0)) {\n if (lastOptionalReadError) throw lastOptionalReadError;\n throw new Error('All Modbus read groups are currently skipped after previous failures');\n }\n\n // Update dynamic scale-factor cache first (order-independent)\n for (const [dpId, raw] of Object.entries(numRawById)) {\n if (dpId.endsWith('_SF')) {\n // SunSpec uses 0x8000 (-32768) as \"not implemented\" for int16\n if (raw !== -32768) this._sfCache.set(dpId, raw);\n }\n }\n for (const ref of scaleFactorRefs) {\n const raw = numRawById[ref];\n if (typeof raw === 'number' && !Number.isNaN(raw) && raw !== -32768) {\n this._sfCache.set(ref, raw);\n }\n }\n\n // Apply numeric transforms (including dynamic scaling) now that SF cache is up-to-date\n for (const [dpId, raw] of Object.entries(numRawById)) {\n const src = srcById[dpId] || {};\n out[dpId] = this._applyTransforms(raw, src);\n }\n } catch (e) {\n if (isTransportError(e)) {\n this._markDisconnected(e);\n }\n throw e;\n } finally {\n this._busy = false;\n this._busySince = 0;\n }\n\n return out;\n}\n\n _getTemplateDpById(dpId) {\n if (!dpId) return null;\n const wanted = String(dpId);\n const dps = (this.template && Array.isArray(this.template.datapoints)) ? this.template.datapoints : [];\n return dps.find(d => d && String(d.id) === wanted) || null;\n }\n\n _getSungrowSignedPowerControlForDp(dpId) {\n const id = String(dpId || '');\n if (!id || !Array.isArray(this._sungrowSignedPowerControls)) return null;\n for (const cfg of this._sungrowSignedPowerControls) {\n if (!cfg || cfg.enabled === false) continue;\n const ids = [];\n if (cfg.triggerDpId) ids.push(String(cfg.triggerDpId));\n if (Array.isArray(cfg.triggerDpIds)) {\n for (const v of cfg.triggerDpIds) if (v !== null && v !== undefined) ids.push(String(v));\n }\n if (ids.includes(id)) return cfg;\n }\n return null;\n }\n\n async _writeDatapointById(dpId, value) {\n const dp = this._getTemplateDpById(dpId);\n if (!dp) throw new Error(`Sungrow compound write datapoint not found: ${dpId}`);\n if (!(dp.rw === 'rw' || dp.rw === 'wo')) throw new Error(`Sungrow compound write datapoint is not writable: ${dpId}`);\n await this.writeDatapoint(dp, value);\n }\n\n async _writeDatapointByIdOptional(dpId, value, label = 'optional write') {\n const dp = this._getTemplateDpById(dpId);\n if (!dp || !(dp.rw === 'rw' || dp.rw === 'wo')) return false;\n try {\n await this.writeDatapoint(dp, value);\n return true;\n } catch (e) {\n // Optional Sungrow helper writes (heartbeat, wide power, command-repeat) must not\n // abort the primary power command. Keep real transport errors fatal so a broken\n // TCP/RTU link still marks the device unhealthy, but swallow Modbus protocol\n // rejections such as exception 4 from unsupported/temporarily invalid helpers.\n if (isTransportError(e) || (!isModbusIllegalAddressOrValue(e) && !isModbusProtocolException(e))) throw e;\n try { this.adapter.log.debug(`[${this.device?.id || 'modbus'}] Sungrow ${label} ${dpId} rejected by device; continuing. ${e && e.message ? e.message : e}`); } catch (_) {}\n return false;\n }\n }\n\n _nextSungrowHeartbeatValue(cfg) {\n const mode = String(cfg?.heartbeatValueMode || cfg?.heartbeatMode || '').toLowerCase();\n const raw = cfg?.heartbeatValue;\n const minRaw = Number(cfg?.heartbeatMinValue ?? cfg?.heartbeatValueMin ?? cfg?.heartbeatWriteMin ?? 0);\n const maxRaw = Number(cfg?.heartbeatMaxValue ?? cfg?.heartbeatValueMax ?? cfg?.heartbeatWriteMax ?? 1000);\n const minAllowed = Number.isFinite(minRaw) && minRaw >= 0 ? Math.trunc(minRaw) : 0;\n const maxAllowed = Number.isFinite(maxRaw) && maxRaw > minAllowed ? Math.trunc(maxRaw) : 1000;\n const defaultRaw = Number(cfg?.heartbeatDefaultValue ?? cfg?.heartbeatFixedValue ?? 20);\n const defaultValue = Number.isFinite(defaultRaw) ? Math.trunc(defaultRaw) : 20;\n const clamp = (v) => {\n const n = Number(v);\n if (!Number.isFinite(n)) return undefined;\n return Math.max(minAllowed, Math.min(maxAllowed, Math.trunc(n)));\n };\n\n if (mode === 'counter' || raw === 'counter' || raw === '__counter__') {\n // Legacy 0.5.128/0.5.129 templates used a monotonic counter here. Sungrow\n // treats the heartbeat register as a timeout in seconds, so the safe default\n // is a fixed in-range timeout value. A real counter can still be forced for\n // lab/testing profiles via forceHeartbeatCounter=true.\n if (cfg?.forceHeartbeatCounter !== true && cfg?.allowHeartbeatCounter !== true) {\n return clamp(defaultValue);\n }\n const minCounterRaw = Number(cfg?.heartbeatCounterMin ?? Math.max(1, minAllowed));\n const maxCounterRaw = Number(cfg?.heartbeatCounterMax ?? maxAllowed);\n const min = Number.isFinite(minCounterRaw) && minCounterRaw >= minAllowed ? Math.trunc(minCounterRaw) : Math.max(1, minAllowed);\n const max = Number.isFinite(maxCounterRaw) && maxCounterRaw > min ? Math.min(Math.trunc(maxCounterRaw), maxAllowed) : maxAllowed;\n const prev = Number(this._sungrowHeartbeatCounter || 0);\n let next = prev + 1;\n if (!Number.isFinite(next) || next < min || next > max) next = min;\n this._sungrowHeartbeatCounter = next;\n return clamp(next);\n }\n if (mode === 'unix' || mode === 'unixmod' || mode === 'time') {\n return clamp(Math.trunc(Date.now() / 1000));\n }\n if (raw !== undefined && raw !== null) {\n return clamp(raw);\n }\n return undefined;\n }\n\n async _maybeWriteSungrowHeartbeat(cfg, value) {\n const dpId = String(cfg?.heartbeatDpId || '').trim();\n if (!dpId || value === undefined || value === null) return false;\n\n const minMsRaw = Number(cfg?.heartbeatMinIntervalMs ?? cfg?.heartbeatRefreshMinMs ?? cfg?.heartbeatWriteMinIntervalMs ?? 0);\n const minMs = Number.isFinite(minMsRaw) && minMsRaw > 0 ? Math.trunc(minMsRaw) : 0;\n const key = `${dpId}`;\n const now = Date.now();\n if (!this._sungrowHeartbeatLastWriteAt || typeof this._sungrowHeartbeatLastWriteAt.get !== 'function') {\n this._sungrowHeartbeatLastWriteAt = new Map();\n }\n const last = Number(this._sungrowHeartbeatLastWriteAt.get(key) || 0);\n if (minMs > 0 && last > 0 && (now - last) < minMs) return true;\n\n const ok = await this._writeDatapointByIdOptional(dpId, value, 'heartbeat');\n if (ok) this._sungrowHeartbeatLastWriteAt.set(key, now);\n return ok;\n }\n\n async refreshSungrowSignedPowerControlHeartbeats(_opts = {}) {\n if (!Array.isArray(this._sungrowSignedPowerControls) || !this._sungrowSignedPowerControls.length) return 0;\n let count = 0;\n const seenHeartbeatDpIds = new Set();\n for (const cfg of this._sungrowSignedPowerControls) {\n if (!cfg || cfg.enabled === false) continue;\n if (!(cfg.heartbeatAutoRefresh === true || cfg.autoRefreshHeartbeat === true)) continue;\n const dpId = String(cfg.heartbeatDpId || '').trim();\n if (!dpId) continue;\n if (seenHeartbeatDpIds.has(dpId)) continue;\n seenHeartbeatDpIds.add(dpId);\n const value = this._nextSungrowHeartbeatValue(cfg);\n const ok = await this._maybeWriteSungrowHeartbeat(cfg, value);\n if (ok) count += 1;\n }\n return count;\n }\n\n _encodeSungrowWriteValue(dpId, value) {\n const dp = this._getTemplateDpById(dpId);\n if (!dp) throw new Error(`Sungrow block-write datapoint not found: ${dpId}`);\n const src = getWriteSource(dp);\n if (!src) throw new Error(`Sungrow block-write datapoint has no write source: ${dpId}`);\n let raw = value;\n if (typeof raw === 'string' && raw.trim() !== '') {\n const n = Number(raw);\n if (!Number.isNaN(n)) raw = n;\n }\n raw = applyWriteValueConstraints(raw, src, dp.id);\n if (typeof raw === 'number') {\n const sf = this._getScaleFactor(src);\n if (sf) raw = removeScale(raw, sf);\n }\n const words = Number(src.length || 1);\n const wo = src.wordOrder || this.wordOrder;\n const bo = src.byteOrder || this.byteOrder;\n const buf = valueToBuffer(raw, src.dataType, words * 2);\n const regs = bufferToRegs(buf, wo, bo);\n const addr = this._addr(src);\n const unitId = this._sourceUnitId(src);\n return { dp, src, raw, words, regs, addr, unitId };\n }\n\n _sungrowProfileKey(cfg, fallback = '') {\n const trigger = String(cfg?.triggerDpId || (Array.isArray(cfg?.triggerDpIds) ? cfg.triggerDpIds.join(',') : '') || fallback || '').trim();\n const mode = String(cfg?.modeDpId || '').trim();\n const command = String(cfg?.commandDpId || cfg?.chargeDischargeCommandDpId || '').trim();\n const power = String(cfg?.powerDpId || cfg?.chargeDischargePowerDpId || '').trim();\n // Key the physical helper path, not only the public trigger datapoint. The\n // hybrid template exposes signed/charge-only/discharge-only public DPs that all\n // share the same Sungrow helper registers; EMS mode should be cached across them.\n const physical = `${mode}|${command}|${power}`;\n return physical.replace(/\\|/g, '') ? physical : trigger;\n }\n\n async _maybeWriteSungrowModeIfNeeded(cfg, modeValue) {\n const modeDpId = String(cfg?.modeDpId || '').trim();\n if (!modeDpId || modeValue === undefined || modeValue === null) return false;\n\n const strategy = String(cfg?.modeWriteStrategy || cfg?.modeStrategy || '').toLowerCase();\n const writeEveryCommand = cfg?.modeWriteEveryCommand === true || cfg?.writeModeEveryCommand === true || strategy === 'always';\n const writeOnce = cfg?.modeWriteOnce === true || strategy === 'once';\n const minRaw = Number(cfg?.modeWriteMinIntervalMs ?? cfg?.modeMinIntervalMs ?? cfg?.modeRefreshIntervalMs ?? 60000);\n const minMs = writeEveryCommand ? 0 : (Number.isFinite(minRaw) && minRaw > 0 ? Math.trunc(minRaw) : 60000);\n const key = this._sungrowProfileKey(cfg, modeDpId);\n const now = Date.now();\n const last = Number(this._sungrowModeLastWriteAt && this._sungrowModeLastWriteAt.get(key) || 0);\n\n if (!writeEveryCommand) {\n if (writeOnce && last > 0) return true;\n if (last > 0 && minMs > 0 && (now - last) < minMs) return true;\n }\n\n await this._writeDatapointById(modeDpId, modeValue);\n if (this._sungrowModeLastWriteAt) this._sungrowModeLastWriteAt.set(key, Date.now());\n try { this.adapter.log.debug(`[${this.device?.id || 'modbus'}] Sungrow EMS mode ensured: ${modeDpId}=${modeValue}`); } catch (_) {}\n return true;\n }\n\n async _maybeWriteSungrowCommandPowerBlock(cfg, commandValue, powerValue) {\n if (!cfg || cfg.blockWrite === false) return false;\n if (cfg.blockCommandPower === false || cfg.blockCommandPowerOnly === false) return false;\n const commandDpId = String(cfg.commandDpId || cfg.chargeDischargeCommandDpId || '').trim();\n const powerDpId = String(cfg.powerDpId || cfg.chargeDischargePowerDpId || '').trim();\n if (!commandDpId || !powerDpId) return false;\n\n let commandEnc;\n let powerEnc;\n try {\n commandEnc = this._encodeSungrowWriteValue(commandDpId, commandValue);\n powerEnc = this._encodeSungrowWriteValue(powerDpId, powerValue);\n } catch (e) {\n try { this.adapter.log.debug(`[${this.device?.id || 'modbus'}] Sungrow command/power FC16 block unavailable; falling back to individual writes. ${e && e.message ? e.message : e}`); } catch (_) {}\n return false;\n }\n\n const unitId = this._operationUnitId(commandEnc.unitId);\n if (this._operationUnitId(powerEnc.unitId) !== unitId) return false;\n if (![6, 16].includes(Number(commandEnc.src.fc)) || ![6, 16].includes(Number(powerEnc.src.fc))) return false;\n if (!Number.isFinite(commandEnc.addr) || !Number.isFinite(powerEnc.addr)) return false;\n\n const start = Math.min(commandEnc.addr, powerEnc.addr);\n const end = Math.max(commandEnc.addr + commandEnc.words - 1, powerEnc.addr + powerEnc.words - 1);\n const totalWords = end - start + 1;\n const maxWords = Number(cfg.commandPowerBlockMaxWords ?? cfg.blockCommandPowerMaxWords ?? cfg.blockMaxWords ?? 4);\n if (!Number.isFinite(totalWords) || totalWords <= 0 || totalWords > maxWords) return false;\n\n // Avoid accidentally writing over undocumented gaps. For Sungrow hybrid V1.1.11\n // this is exactly 13051..13052 (two U16 registers).\n if (cfg.requireContiguousCommandPower !== false) {\n const usedWords = Number(commandEnc.words || commandEnc.regs.length || 0) + Number(powerEnc.words || powerEnc.regs.length || 0);\n if (usedWords !== totalWords) return false;\n }\n\n const regs = Array(totalWords).fill(0);\n const place = (enc) => {\n const off = enc.addr - start;\n for (let i = 0; i < enc.regs.length; i++) regs[off + i] = enc.regs[i];\n };\n place(commandEnc);\n place(powerEnc);\n\n try {\n await this._mbWriteRegisters(start, regs, unitId);\n try { this.adapter.log.debug(`[${this.device?.id || 'modbus'}] Sungrow command/power FC16 block written: UID${unitId} @${start} len=${regs.length} command=${commandValue}, power=${powerValue}`); } catch (_) {}\n return true;\n } catch (e) {\n if (isTransportError(e) || (!isModbusIllegalAddressOrValue(e) && !isModbusProtocolException(e))) throw e;\n try { this.adapter.log.debug(`[${this.device?.id || 'modbus'}] Sungrow command/power FC16 block rejected; falling back to individual writes. ${e && e.message ? e.message : e}`); } catch (_) {}\n return false;\n }\n }\n\n async _maybeWriteSungrowControlBlock(cfg, modeValue, commandValue, powerValue) {\n if (!cfg || cfg.blockWrite === false || cfg.blockModeCommandPower === false) return false;\n const modeDpId = String(cfg.modeDpId || '').trim();\n const commandDpId = String(cfg.commandDpId || cfg.chargeDischargeCommandDpId || '').trim();\n const powerDpId = String(cfg.powerDpId || cfg.chargeDischargePowerDpId || '').trim();\n if (!modeDpId || !commandDpId || !powerDpId) return false;\n if (modeValue === undefined || modeValue === null) return false;\n\n let modeEnc;\n let commandEnc;\n let powerEnc;\n try {\n modeEnc = this._encodeSungrowWriteValue(modeDpId, modeValue);\n commandEnc = this._encodeSungrowWriteValue(commandDpId, commandValue);\n powerEnc = this._encodeSungrowWriteValue(powerDpId, powerValue);\n } catch (e) {\n try { this.adapter.log.debug(`[${this.device?.id || 'modbus'}] Sungrow FC16 control block unavailable; falling back to individual writes. ${e && e.message ? e.message : e}`); } catch (_) {}\n return false;\n }\n\n const unitId = this._operationUnitId(modeEnc.unitId);\n if (this._operationUnitId(commandEnc.unitId) !== unitId || this._operationUnitId(powerEnc.unitId) !== unitId) return false;\n if (![6, 16].includes(Number(modeEnc.src.fc)) || ![6, 16].includes(Number(commandEnc.src.fc)) || ![6, 16].includes(Number(powerEnc.src.fc))) return false;\n if (!Number.isFinite(modeEnc.addr) || !Number.isFinite(commandEnc.addr) || !Number.isFinite(powerEnc.addr)) return false;\n\n const start = Math.min(modeEnc.addr, commandEnc.addr, powerEnc.addr);\n const end = Math.max(modeEnc.addr + modeEnc.words - 1, commandEnc.addr + commandEnc.words - 1, powerEnc.addr + powerEnc.words - 1);\n const totalWords = end - start + 1;\n const maxWords = Number(cfg.blockMaxWords ?? 8);\n if (!Number.isFinite(totalWords) || totalWords <= 0 || totalWords > maxWords) return false;\n\n const regs = Array(totalWords).fill(0);\n const place = (enc) => {\n const off = enc.addr - start;\n for (let i = 0; i < enc.regs.length; i++) regs[off + i] = enc.regs[i];\n };\n place(modeEnc);\n place(commandEnc);\n place(powerEnc);\n\n try {\n await this._mbWriteRegisters(start, regs, unitId);\n try { this.adapter.log.debug(`[${this.device?.id || 'modbus'}] Sungrow FC16 control block written: UID${unitId} @${start} len=${regs.length} mode=${modeValue}, command=${commandValue}, power=${powerValue}`); } catch (_) {}\n return true;\n } catch (e) {\n if (isTransportError(e) || (!isModbusIllegalAddressOrValue(e) && !isModbusProtocolException(e))) throw e;\n try { this.adapter.log.debug(`[${this.device?.id || 'modbus'}] Sungrow FC16 control block rejected; falling back to individual writes. ${e && e.message ? e.message : e}`); } catch (_) {}\n return false;\n }\n }\n\n async _clampSungrowSignedPowerW(cfg, signedPowerW, commandValue, chargeValue, dischargeValue) {\n if (!cfg || cfg.clampToLimitDp === false) return signedPowerW;\n const n = Number(signedPowerW);\n if (!Number.isFinite(n) || n === 0) return signedPowerW;\n\n const isCharge = Number(commandValue) === Number(chargeValue);\n const isDischarge = Number(commandValue) === Number(dischargeValue);\n const limitDpId = isCharge\n ? String(cfg.maxChargePowerDpId || cfg.chargeLimitDpId || '').trim()\n : isDischarge\n ? String(cfg.maxDischargePowerDpId || cfg.dischargeLimitDpId || '').trim()\n : '';\n if (!limitDpId) return signedPowerW;\n\n const limit = await this._getDpStateNumber(limitDpId);\n if (!Number.isFinite(limit) || limit <= 0) return signedPowerW;\n const abs = Math.abs(Math.round(n));\n if (abs <= limit) return signedPowerW;\n\n const clamped = Math.round(limit) * (n < 0 ? -1 : 1);\n try { this.adapter.log.debug(`[${this.device?.id || 'modbus'}] Sungrow setpoint ${abs} W exceeds ${limitDpId}=${limit} W; clamped to ${Math.abs(clamped)} W.`); } catch (_) {}\n return clamped;\n }\n\n async _maybeWriteSungrowSignedPowerControl(dp, value) {\n const cfg = this._getSungrowSignedPowerControlForDp(dp && dp.id);\n if (!cfg) return false;\n\n const currentDpId = String(dp && dp.id ? dp.id : '');\n const powerDpId = String(cfg.powerDpId || cfg.chargeDischargePowerDpId || '').trim();\n const commandDpId = String(cfg.commandDpId || cfg.chargeDischargeCommandDpId || '').trim();\n if (!powerDpId || !commandDpId) throw new Error('Sungrow signed power control requires commandDpId and powerDpId');\n if (powerDpId === currentDpId || commandDpId === currentDpId) {\n throw new Error(`Sungrow signed power control must use helper datapoints different from trigger ${currentDpId}`);\n }\n\n let signedPowerW = Number(value);\n if (!Number.isFinite(signedPowerW)) throw new Error(`Invalid Sungrow power setpoint: ${value}`);\n\n const deadbandWRaw = Number(cfg.zeroDeadbandW ?? cfg.deadbandW ?? 0);\n const deadbandW = Number.isFinite(deadbandWRaw) && deadbandWRaw > 0 ? deadbandWRaw : 0;\n let roundedW = Math.round(signedPowerW);\n let absW = Math.abs(roundedW);\n\n const positiveIsCharge = cfg.positiveIsCharge === true;\n let isStop = absW <= deadbandW;\n const chargeValue = Number(cfg.chargeValue ?? 0xAA);\n const dischargeValue = Number(cfg.dischargeValue ?? 0xBB);\n const stopValue = Number(cfg.stopValue ?? 0xCC);\n const modeValue = cfg.modeValue;\n\n // Direction handling:\n // - default/signed: one signed setpoint (+W discharge, -W charge by default)\n // - fixed charge/discharge: EMS can map a simple positive chargePowerW or dischargePowerW\n // datapoint and the driver still writes the Sungrow command+power register pair.\n const directionMode = String(cfg.direction || cfg.fixedDirection || cfg.powerDirection || cfg.commandDirection || '').toLowerCase().replace(/[\\s_-]+/g, '');\n const fixedCharge = ['charge', 'charging', 'batcharge', 'batterycharge'].includes(directionMode);\n const fixedDischarge = ['discharge', 'discharging', 'batdischarge', 'batterydischarge'].includes(directionMode);\n const fixedStop = ['stop', 'off', 'zero'].includes(directionMode);\n\n let commandValue;\n if (fixedStop) {\n isStop = true;\n commandValue = stopValue;\n roundedW = 0;\n absW = 0;\n } else if (fixedCharge || fixedDischarge) {\n // Treat the fixed-direction datapoints as absolute W inputs. Negative user input is\n // accepted but normalized to its magnitude so EMS integrations do not need to know\n // Sungrow's separate direction register.\n absW = Math.abs(roundedW);\n isStop = absW <= deadbandW;\n commandValue = isStop ? stopValue : (fixedCharge ? chargeValue : dischargeValue);\n if (!isStop) {\n const signedForLimit = fixedCharge\n ? (positiveIsCharge ? absW : -absW)\n : (positiveIsCharge ? -absW : absW);\n const clampedSigned = await this._clampSungrowSignedPowerW(cfg, signedForLimit, commandValue, chargeValue, dischargeValue);\n absW = Math.abs(Math.round(Number(clampedSigned)));\n isStop = absW <= deadbandW;\n if (isStop) commandValue = stopValue;\n }\n } else if (isStop) {\n commandValue = stopValue;\n } else {\n const wantsCharge = positiveIsCharge ? (roundedW > 0) : (roundedW < 0);\n commandValue = wantsCharge ? chargeValue : dischargeValue;\n const clampedSigned = await this._clampSungrowSignedPowerW(cfg, roundedW, commandValue, chargeValue, dischargeValue);\n roundedW = Math.round(Number(clampedSigned));\n absW = Math.abs(roundedW);\n isStop = absW <= deadbandW;\n if (isStop) commandValue = stopValue;\n }\n\n const powerValue = (!isStop || cfg.writePowerOnStop !== false) ? absW : 0;\n const heartbeatValue = this._nextSungrowHeartbeatValue(cfg);\n\n // Sungrow hybrid protocol V1.1.11: EMS receives one signed power datapoint from\n // Nexowatt/EOS, while the inverter expects several protocol registers. Keep this\n // complexity in the device adapter. Prefer a single contiguous FC16 write over\n // 13050..13052 when the template opts into it. This avoids a slow sequence of\n // mode write -> command/power write and prevents the inverter from briefly seeing\n // a stale charge/discharge command while the next register is still queued.\n let blockOk = false;\n const preferFullControlBlock = (cfg.blockModeCommandPower === true && cfg.blockCommandPowerOnly !== true);\n\n if (preferFullControlBlock) {\n blockOk = await this._maybeWriteSungrowControlBlock(cfg, modeValue, commandValue, powerValue);\n }\n\n // Fallback / alternate profile: ensure EMS mode separately, then write only\n // command+power together over 13051..13052.\n if (!blockOk) {\n await this._maybeWriteSungrowModeIfNeeded(cfg, modeValue);\n\n if (cfg.blockCommandPower !== false && cfg.blockCommandPowerOnly !== false) {\n blockOk = await this._maybeWriteSungrowCommandPowerBlock(cfg, commandValue, powerValue);\n }\n }\n\n // Last-resort fallback: individual helper writes. Write power before command so\n // devices that latch on command edge do not reuse an older power value.\n if (!blockOk) {\n if (!isStop || cfg.writePowerOnStop !== false) {\n await this._writeDatapointById(powerDpId, powerValue);\n }\n await this._writeDatapointById(commandDpId, commandValue);\n }\n\n // Newer/high-power Sungrow hybrid profiles expose a wide-range power helper in\n // addition to the original 13052-style register. Write it best-effort with the\n // same command value so SHxxT/MG profiles do not silently ignore high setpoints.\n const widePowerMode = String(cfg.widePowerWriteMode || cfg.powerWideWriteMode || '').toLowerCase();\n const widePowerDisabled = cfg.writeWidePower === false || cfg.autoWriteWidePower === false || widePowerMode === 'never' || widePowerMode === 'off' || widePowerMode === 'disabled';\n const widePowerDpId = widePowerDisabled ? '' : String(cfg.widePowerDpId || cfg.powerWideDpId || cfg.chargeDischargePowerWideDpId || '').trim();\n if (widePowerDpId && (!isStop || cfg.writePowerOnStop !== false) && widePowerDpId !== powerDpId) {\n await this._writeDatapointByIdOptional(widePowerDpId, powerValue, 'wide power');\n if (cfg.repeatCommandAfterWidePower !== false) {\n await this._writeDatapointByIdOptional(commandDpId, commandValue, 'command after wide power');\n }\n }\n\n // Optional heartbeat refresh for External EMS/VPP modes. Sungrow expects a\n // timeout value in seconds (normally 20), not a monotonically increasing counter.\n // Write it after mode/command/power so a device that only accepts the heartbeat\n // while already in External EMS/VPP mode still receives it immediately.\n await this._maybeWriteSungrowHeartbeat(cfg, heartbeatValue);\n\n return true;\n }\n\n\n _isKebaP40Profile() {\n const tplIdLower = String((this.template && this.template.id) || this.device?.templateId || this.device?.template || '').toLowerCase();\n const mfrLower = String((this.template && this.template.manufacturer) || this.device?.manufacturer || this.device?.vendor || '').toLowerCase();\n const modelLower = String((this.template && this.template.model) || this.device?.model || '').toLowerCase();\n return (mfrLower === 'keba' || tplIdLower.includes('keba')) && (tplIdLower.includes('p40') || modelLower.includes('p40') || tplIdLower.includes('evcskebamodbusimpl'));\n }\n\n async _maybePrepareKebaP40Write(dp) {\n if (!this._isKebaP40Profile()) return;\n const dpId = String(dp && dp.id ? dp.id : '');\n if (dpId !== 'sET_TRIGGER_PHASE_SWITCH') return;\n\n const hints = (this.template && this.template.driverHints && this.template.driverHints.keba) || {};\n if (hints.phaseSwitchPrewriteSource === false) return;\n\n const sourceDp = this._getTemplateDpById('sET_PHASE_SWITCH_SOURCE');\n if (!sourceDp || !(sourceDp.rw === 'rw' || sourceDp.rw === 'wo')) return;\n\n // KEBA P40 requires phase-switch source register 5050 to be set to 3 (Modbus)\n // before register 5052 can trigger 1-/3-phase switching. Registers 5050/5052\n // are firmware-dependent, so an unsupported pre-write must not break a direct\n // 5052 command if the source is already configured on the charger.\n try {\n await this.writeDatapoint(sourceDp, 3);\n } catch (e) {\n if (!isModbusIllegalAddressOrValue(e)) throw e;\n try {\n this.adapter.log.debug(`[${this.device?.id || 'modbus'}] KEBA P40 phase-switch source pre-write was rejected; continuing with trigger command. ${e && e.message ? e.message : e}`);\n } catch (_) {}\n }\n }\n\n _isDepowerV1003ControlProfile() {\n if (!this._depowerV1003 || typeof this._depowerV1003 !== 'object') return false;\n if (this._depowerV1003.controlSequenceEnabled === false) return false;\n const tplId = String((this.template && this.template.id) || this.device?.templateId || '').toLowerCase();\n const manufacturer = String((this.template && this.template.manufacturer) || this.device?.manufacturer || '').toLowerCase();\n return manufacturer === 'depower' || tplId.includes('evcs.oem.modbusv1003.connector');\n }\n\n _getDepowerV1003ControlConfig() {\n if (!this._isDepowerV1003ControlProfile()) return null;\n const cfg = this._depowerV1003 || {};\n const connectorRaw = Number(cfg.connector ?? 1);\n const connector = Number.isFinite(connectorRaw) && connectorRaw >= 1 ? Math.trunc(connectorRaw) : 1;\n const delayRaw = Number(cfg.prepareRearmDelayMs ?? cfg.stopStartDelayMs ?? 500);\n const cooldownRaw = Number(cfg.prepareRearmCooldownMs ?? cfg.rearmCooldownMs ?? 5000);\n return {\n connector,\n chargeModeDpId: String(cfg.chargeModeDpId || 'cHARGE_MODE'),\n chargeModeValue: Number(cfg.chargeModeValue ?? 1),\n gunCountDpId: String(cfg.gunCountDpId || 'gUN_COUNT'),\n stationPowerDpId: String(cfg.stationPowerDpId || 'cHARGE_POINT_SET_POWER'),\n connectorPowerDpId: String(cfg.connectorPowerDpId || 'eV_SET_CHARGE_POWER_LIMIT'),\n chargeCommandDpId: String(cfg.chargeCommandDpId || 'cHARGE_COMMAND'),\n connectorStateDpId: String(cfg.connectorStateDpId || 'eVSE_STATE'),\n plugStateDpId: String(cfg.plugStateDpId || 'pLUG_STATE'),\n startValue: Number(cfg.startValue ?? 1),\n stopValue: Number(cfg.stopValue ?? 2),\n ensureChargeMode: cfg.ensureChargeMode !== false,\n initializeStationPowerWhenZero: cfg.initializeStationPowerWhenZero !== false,\n stationPowerSingleConnectorOnly: cfg.stationPowerSingleConnectorOnly !== false,\n rearmPrepareWithStopStart: cfg.rearmPrepareWithStopStart !== false,\n prepareRearmDelayMs: Number.isFinite(delayRaw) && delayRaw >= 0 ? Math.trunc(delayRaw) : 500,\n prepareRearmCooldownMs: Number.isFinite(cooldownRaw) && cooldownRaw >= 0 ? Math.trunc(cooldownRaw) : 5000,\n };\n }\n\n async _getDeviceStateValue(relativeSuffix) {\n const suffix = String(relativeSuffix || '').trim();\n if (!suffix) return undefined;\n try {\n const fullId = `${this.adapter.namespace}.devices.${this.device.id}.${suffix}`;\n const state = await this.adapter.getStateAsync(fullId);\n if (!state || state.val === null || state.val === undefined) return undefined;\n return state.val;\n } catch (_) {\n return undefined;\n }\n }\n\n _toDepowerBoolean(value) {\n if (typeof value === 'boolean') return value;\n if (typeof value === 'number' && Number.isFinite(value)) return value !== 0;\n if (typeof value === 'string') {\n const text = value.trim().toLowerCase();\n if (['true', '1', 'on', 'an', 'start', 'enabled', 'enable'].includes(text)) return true;\n if (['false', '0', '2', 'off', 'aus', 'stop', 'disabled', 'disable'].includes(text)) return false;\n }\n return undefined;\n }\n\n async _resolveDepowerRunDesired(cfg) {\n if (typeof this._depowerDesiredRun === 'boolean') return this._depowerDesiredRun;\n\n for (const suffix of ['aliases.v1.ctrl.run', 'aliases.ctrl.run', 'aliases.ctrl.chargeEnable']) {\n const parsed = this._toDepowerBoolean(await this._getDeviceStateValue(suffix));\n if (typeof parsed === 'boolean') return parsed;\n }\n\n const raw = await this._getDpStateNumber(cfg.chargeCommandDpId);\n if (Number.isFinite(raw)) {\n if (Math.trunc(raw) === Math.trunc(cfg.startValue)) return true;\n if (Math.trunc(raw) === Math.trunc(cfg.stopValue)) return false;\n }\n return undefined;\n }\n\n async _resolveDepowerPowerDesired(cfg) {\n if (Number.isFinite(this._depowerDesiredPowerW)) return Math.max(0, Math.round(this._depowerDesiredPowerW));\n\n for (const suffix of ['aliases.v1.ctrl.powerLimitW', 'aliases.ctrl.powerLimitW']) {\n const value = await this._getDeviceStateValue(suffix);\n const number = Number(value);\n if (Number.isFinite(number) && number >= 0) return Math.round(number);\n }\n\n const raw = await this._getDpStateNumber(cfg.connectorPowerDpId);\n return Number.isFinite(raw) && raw >= 0 ? Math.round(raw) : undefined;\n }\n\n async _writeDepowerHelper(dpId, value) {\n const target = this._getTemplateDpById(dpId);\n if (!target) throw new Error(`DEPower control datapoint not found: ${dpId}`);\n if (!(target.rw === 'rw' || target.rw === 'wo')) throw new Error(`DEPower control datapoint is not writable: ${dpId}`);\n await this.writeDatapoint(target, value, { depowerRegisterWrite: true });\n }\n\n async _prepareDepowerV1003Control(cfg, powerW) {\n if (cfg.ensureChargeMode) {\n await this._writeDepowerHelper(cfg.chargeModeDpId, cfg.chargeModeValue);\n }\n\n let stationPowerInitialized = false;\n if (cfg.initializeStationPowerWhenZero && Number.isFinite(powerW) && powerW > 0) {\n const currentStationPower = await this._getDpStateNumber(cfg.stationPowerDpId);\n const gunCount = await this._getDpStateNumber(cfg.gunCountDpId);\n const mayInitialize = !cfg.stationPowerSingleConnectorOnly || (Number.isFinite(gunCount) && Math.trunc(gunCount) === 1);\n\n // A positive station-wide value is treated as an intentional local/site limit and\n // is never raised by NexoWatt. Only the undocumented/default 0 value is initialized,\n // and only for a confirmed single-connector station, so dual-connector power sharing\n // is not disturbed by one connector instance.\n if (mayInitialize && (!Number.isFinite(currentStationPower) || currentStationPower <= 0)) {\n await this._writeDepowerHelper(cfg.stationPowerDpId, Math.round(powerW));\n stationPowerInitialized = true;\n }\n }\n\n return { stationPowerInitialized };\n }\n\n async _maybeWriteDepowerV1003Control(dp, value) {\n const cfg = this._getDepowerV1003ControlConfig();\n if (!cfg) return false;\n\n const id = String(dp && dp.id || '');\n if (id !== cfg.connectorPowerDpId && id !== cfg.chargeCommandDpId) return false;\n // A shared recursion-depth flag also bypassed coordination for unrelated\n // concurrent calls. Serialize whole control sequences; only helper writes\n // explicitly bypass this queue.\n const run = () => this._executeDepowerV1003Control(cfg, dp, value);\n const pending = this._depowerControlQueue.then(run, run);\n this._depowerControlQueue = pending.catch(() => {});\n return pending;\n }\n\n async _executeDepowerV1003Control(cfg, dp, value) {\n const dpId = String(dp && dp.id || '');\n const isPowerCommand = dpId === cfg.connectorPowerDpId;\n const isRunCommand = dpId === cfg.chargeCommandDpId;\n if (!isPowerCommand && !isRunCommand) return false;\n\n const src = getWriteSource(dp);\n if (!src) throw new Error(`DEPower datapoint ${dpId} has no write source`);\n let normalized = applyWriteValueConstraints(value, src, dpId);\n if (typeof normalized === 'string' && normalized.trim() !== '') normalized = Number(normalized);\n if (!Number.isFinite(Number(normalized))) throw new Error(`Invalid DEPower control value for ${dpId}: ${value}`);\n normalized = Math.round(Number(normalized));\n\n if (isPowerCommand) this._depowerDesiredPowerW = Math.max(0, normalized);\n if (isRunCommand) this._depowerDesiredRun = normalized === Math.trunc(cfg.startValue);\n\n if (isRunCommand && normalized === Math.trunc(cfg.stopValue)) {\n await this._writeDepowerHelper(cfg.chargeCommandDpId, cfg.stopValue);\n return { effectiveValue: normalized };\n }\n\n const desiredPowerW = isPowerCommand\n ? Math.max(0, normalized)\n : await this._resolveDepowerPowerDesired(cfg);\n const desiredRun = isRunCommand\n ? normalized === Math.trunc(cfg.startValue)\n : await this._resolveDepowerRunDesired(cfg);\n\n const prep = await this._prepareDepowerV1003Control(cfg, desiredPowerW);\n\n // The connector limit must be present before the Start edge. This also makes a\n // later power command self-healing when the initial Start arrived while the station\n // was still in its default/Prepare mode.\n if (Number.isFinite(desiredPowerW)) {\n await this._writeDepowerHelper(cfg.connectorPowerDpId, Math.max(0, Math.round(desiredPowerW)));\n }\n\n if (desiredRun === true && Number.isFinite(desiredPowerW) && desiredPowerW > 0) {\n const connectorState = await this._getDpStateNumber(cfg.connectorStateDpId);\n const plugState = await this._getDpStateNumber(cfg.plugStateDpId);\n const inPrepare = Number.isFinite(connectorState) && Math.trunc(connectorState) === 1;\n const vehiclePresent = !Number.isFinite(plugState) || Math.trunc(plugState) === 1;\n const now = Date.now();\n const rearmDue = !cfg.prepareRearmCooldownMs || !this._depowerLastPrepareRearmAt ||\n (now - this._depowerLastPrepareRearmAt) >= cfg.prepareRearmCooldownMs;\n\n if (cfg.rearmPrepareWithStopStart && inPrepare && vehiclePresent && rearmDue) {\n // Some DEPower firmware keeps Charge command=1 as a level while remaining in\n // Prepare. A deliberate 2 -> 1 edge after mode and power are valid re-arms the\n // connector without touching an already active charging session.\n await this._writeDepowerHelper(cfg.chargeCommandDpId, cfg.stopValue);\n if (cfg.prepareRearmDelayMs > 0) await sleep(cfg.prepareRearmDelayMs);\n await this._writeDepowerHelper(cfg.chargeCommandDpId, cfg.startValue);\n this._depowerLastPrepareRearmAt = Date.now();\n try {\n this.adapter.log.info(\n `[${this.device?.id || 'modbus'}] DEPower connector ${cfg.connector} re-armed from Prepare: ` +\n `chargeMode=${cfg.chargeModeValue}, connectorPower=${Math.round(desiredPowerW)} W, ` +\n `${prep.stationPowerInitialized ? `stationPower initialized=${Math.round(desiredPowerW)} W, ` : ''}` +\n `command=${cfg.stopValue}->${cfg.startValue}.`,\n );\n } catch (_) {}\n } else if (!Number.isFinite(connectorState) || Math.trunc(connectorState) !== 2) {\n // For Idle/Suspended/unknown state, re-send Start after the prerequisites.\n // Do not send it while state=Charging to avoid unnecessary command traffic.\n await this._writeDepowerHelper(cfg.chargeCommandDpId, cfg.startValue);\n }\n }\n\n return { effectiveValue: normalized };\n }\n\n async writeDatapoint(dp, value, options = {}) {\n let writeContext = null;\n\n const setWriteContext = (src, fc, addr, raw, words, unitId) => {\n writeContext = {\n dpId: String(dp?.id || ''),\n fc: Number(fc),\n unitId: this._operationUnitId(unitId ?? this._sourceUnitId(src)),\n address: Number(addr),\n templateAddress: Number(src?.address),\n length: Number(words || src?.length || 1),\n value: raw,\n };\n };\n\n const annotateWriteError = (err) => {\n if (!err || typeof err !== 'object') return err;\n try { err.nexowattOperation = 'write'; } catch (_) {}\n try { err.nexowattDpId = String(dp?.id || ''); } catch (_) {}\n if (writeContext && !err._nexowattWriteContextAnnotated) {\n const ctx = `Write ${writeContext.dpId || 'datapoint'} UID${writeContext.unitId} FC${writeContext.fc}@${writeContext.address}` +\n ` len=${writeContext.length}` +\n (Number.isFinite(writeContext.templateAddress) ? ` templateAddress=${writeContext.templateAddress}` : '') +\n ` value=${writeContext.value}`;\n try { err.message = `${ctx} failed: ${err.message || String(err)}`; } catch (_) {}\n try { err._nexowattWriteContextAnnotated = true; } catch (_) {}\n }\n return err;\n };\n\n const attempt = async () => {\n await this.ensureConnected();\n\n if (await this._maybeWriteSungrowSignedPowerControl(dp, value)) return;\n\n // DEPower AC/DC control requires a coordinated sequence instead of independent\n // writes. Only explicit internal register writes bypass the sequence queue.\n if (!options.depowerRegisterWrite) {\n const depowerResult = await this._maybeWriteDepowerV1003Control(dp, value);\n if (depowerResult) return depowerResult;\n }\n\n const src = getWriteSource(dp);\n if (!src) throw new Error('Datapoint has no Modbus write source');\n\n await this._maybePrepareKebaP40Write(dp);\n\n // SunSpec: resolve model map (ID -> start offset) so writes can compute absolute addresses.\n if (src.sunspecModel !== undefined && src.sunspecModel !== null) {\n try { await this._maybeScanSunSpecModels(); } catch (_) {}\n }\n\n // Some devices require an explicit unlock step before accepting write commands.\n // This is enabled via template driverHints.modbus.writeUnlock.\n await this._maybeUnlockForWrite(src);\n\n const fc = Number(src.fc);\n const addr = this._addr(src);\n const unitId = this._sourceUnitId(src);\n if (!Number.isFinite(addr)) {\n throw new Error(`Invalid Modbus address (SunSpec model missing?) for datapoint ${dp?.id || ''}`);\n }\n\n // Optional safety check for movable OpenEMS/FENECON write-access blocks.\n // The write is performed only when the component header still identifies\n // the documented component at the expected address.\n await this._maybeVerifyWriteComponentId(dp, src, unitId);\n\n // Alfen is handled by a dedicated adaptive control writer below.\n // Do not let the simple probe suppress the alternate ACE control address\n // before we have tested it.\n if (!this._isAlfenProfile) {\n await this._maybeProbeAlfenControlBeforeWrite(dp, src, addr, Number(src.length || 1), unitId);\n }\n\n if (fc === 5) {\n setWriteContext(src, fc, addr, value, 1, unitId);\n await this._mbWriteCoil(addr, !!value, unitId);\n return;\n }\n\n if (fc === 15) {\n // Write multiple coils (we support single-coil use as well)\n setWriteContext(src, fc, addr, value, 1, unitId);\n await this._mbWriteCoils(addr, [!!value], unitId);\n return;\n }\n\n // Prepare numeric value for register writes\n let raw = value;\n if (typeof raw === 'string' && raw.trim() !== '') {\n // allow numeric strings\n const n = Number(raw);\n if (!Number.isNaN(n)) raw = n;\n }\n\n // Optional explicit boolean value mapping (e.g. Sungrow 0xAA/0x55 switches).\n if (typeof raw === 'boolean') {\n const parseBoolMap = (x) => {\n if (x === null || x === undefined) return undefined;\n if (typeof x === 'number' && Number.isFinite(x)) return x;\n if (typeof x === 'string') {\n const st = x.trim().toLowerCase();\n if (!st) return undefined;\n if (st.startsWith('0x')) {\n const n = parseInt(st, 16);\n return Number.isFinite(n) ? n : undefined;\n }\n const n = Number(st);\n return Number.isFinite(n) ? n : undefined;\n }\n return undefined;\n };\n const trueValue = parseBoolMap(src.trueValue ?? src.onValue ?? src.enableValue ?? src.valueTrue);\n const falseValue = parseBoolMap(src.falseValue ?? src.offValue ?? src.disableValue ?? src.valueFalse);\n if (raw === true && trueValue !== undefined) raw = trueValue;\n if (raw === false && falseValue !== undefined) raw = falseValue;\n }\n\n // Validate/map before scaling (template constraints are expressed in user/device engineering units).\n raw = applyWriteValueConstraints(raw, src, dp?.id);\n\n // Undo scaling for write direction (Channel -> Element)\n if (typeof raw === 'number') {\n const sf = this._getScaleFactor(src);\n if (sf) raw = removeScale(raw, sf);\n }\n\n const wo = src.wordOrder || this.wordOrder;\n const bo = src.byteOrder || this.byteOrder;\n\n // --- Special case: SolaX VPP Mode 4 requires a single FC16 multi-write starting at 0x00A0 ---\n // The V1.4 VPP protocol doc says *all* mode parameters must be written starting at 0x00A0\n // with a mode-specific length (for mode 4: 5 registers = 0xA0..0xA4). Writing only 0xA1/0xA3\n // individually may be ignored by newer firmware.\n const vpp4 = this._solaxVppMode4;\n const triggerId = (vpp4 && vpp4.triggerDpId) ? String(vpp4.triggerDpId) : 'sET_ACTIVE_POWER';\n if (\n fc === 16 &&\n vpp4 && vpp4.enabled === true &&\n String(dp?.id) === triggerId\n ) {\n const startAddress = Number(vpp4.startAddress ?? 160);\n const modeNum = Number(vpp4.modeNum ?? 4);\n const execDpId = (vpp4.execDurationDpId || 'vPP_WAIT_TIMEOUT').toString();\n const nextDpId = (vpp4.nextMotionDpId || 'vPP_NEXT_MOTION').toString();\n\n // Defaults (used if state values are not available / invalid)\n const defaultExec = Number(vpp4.defaultExecDuration ?? 600);\n const defaultNext = Number(vpp4.defaultNextMotion ?? 160);\n\n // Optional per-device overrides via existing datapoint states\n let execDuration = await this._getDpStateNumber(execDpId);\n if (!Number.isFinite(execDuration) || execDuration <= 0) execDuration = defaultExec;\n execDuration = Math.round(execDuration);\n if (execDuration < 0) execDuration = 0;\n if (execDuration > 0xFFFF) execDuration = 0xFFFF;\n\n let nextMotion = await this._getDpStateNumber(nextDpId);\n if (!Number.isFinite(nextMotion) || nextMotion <= 0) nextMotion = defaultNext;\n nextMotion = Math.round(nextMotion);\n // Valid values per VPP protocol: 0x00A0 (exit VPP) or 0x00A1 (switch to default VPP mode 6)\n if (nextMotion !== 0x00A0 && nextMotion !== 0x00A1) nextMotion = defaultNext;\n\n // SolaX VPP Mode 4: BatWTarget is an S32. Ensure integer W.\n const powerW = Math.round(Number(raw) || 0);\n\n // Build register block: [VPPModeNum, BatWTarget_L, BatWTarget_H, ExecDuration, NextMotion]\n const blockRegs = [];\n blockRegs.push(...bufferToRegs(valueToBuffer(modeNum, 'uint16', 2), wo, bo));\n blockRegs.push(...bufferToRegs(valueToBuffer(powerW, 'int32', 4), wo, bo));\n blockRegs.push(...bufferToRegs(valueToBuffer(execDuration, 'uint16', 2), wo, bo));\n blockRegs.push(...bufferToRegs(valueToBuffer(nextMotion, 'uint16', 2), wo, bo));\n\n const blockAddr = this._addr({ address: startAddress });\n await this._mbWriteRegisters(blockAddr, blockRegs, unitId);\n return;\n }\n\n\n // --- Special case: SolaX VPP Mode 8 requires a single FC16 multi-write starting at 0x00A0 ---\n // Mode 8: PV&BAT Individual Setting - Duration Mode\n // The V1.4 VPP protocol doc says *all* mode parameters must be written starting at 0x00A0\n // with a mode-specific length (for mode 8: 8 registers = 0xA0..0xA7). Writing only 0xA2/0xA4\n // individually may be ignored by newer firmware.\n const vpp8 = this._solaxVppMode8;\n\n // VPP8 should behave like our VPP4 handling: writing a single \"main\" setpoint datapoint\n // commits *all* required VPP parameters in one FC16 block write.\n //\n // For mode 8 we support BOTH setpoints as triggers:\n // - PV power target (default dpId: sET_PV_POWER)\n // - Battery power target (default dpId: vPP8_BATTERY_POWER_TARGET)\n //\n // This keeps EMS integration simple (you can update either PV or BAT with a single write).\n const pvTargetDpId = (vpp8 && (vpp8.pvTargetDpId || vpp8.pvWTargetDpId))\n ? String(vpp8.pvTargetDpId || vpp8.pvWTargetDpId)\n : 'sET_PV_POWER';\n\n const batTargetDpId = (vpp8 && vpp8.batTargetDpId)\n ? String(vpp8.batTargetDpId)\n : 'vPP8_BATTERY_POWER_TARGET';\n\n const triggerIds = (() => {\n if (!vpp8) return [pvTargetDpId, batTargetDpId];\n if (Array.isArray(vpp8.triggerDpIds) && vpp8.triggerDpIds.length) {\n return vpp8.triggerDpIds.map(v => String(v)).filter(v => v && v.trim());\n }\n const primary = (vpp8.triggerDpId ? String(vpp8.triggerDpId) : pvTargetDpId).trim();\n const out = [];\n if (primary) out.push(primary);\n // Always include both setpoints unless explicitly overridden via triggerDpIds\n if (pvTargetDpId && !out.includes(pvTargetDpId)) out.push(pvTargetDpId);\n if (batTargetDpId && !out.includes(batTargetDpId)) out.push(batTargetDpId);\n return out;\n })();\n\n const currentDpId = String(dp?.id ?? '');\n if (\n fc === 16 &&\n vpp8 && vpp8.enabled === true &&\n triggerIds.includes(currentDpId)\n ) {\n const startAddress = Number(vpp8.startAddress ?? 160);\n const modeNum = Number(vpp8.modeNum ?? 8);\n\n const targetSetTypeDpId = (vpp8.targetSetTypeDpId || 'vPP8_TARGET_SET_TYPE').toString();\n const execDpId = (vpp8.execDurationDpId || 'vPP8_EXEC_DURATION').toString();\n const nextDpId = (vpp8.nextMotionDpId || 'vPP8_NEXT_MOTION').toString();\n\n // Defaults (used if state values are not available / invalid)\n const defaultTargetSetType = Number(vpp8.defaultTargetSetType ?? 1);\n const defaultPvTarget = Number(vpp8.defaultPvTarget ?? vpp8.defaultPvWTarget ?? 0);\n const defaultBatTarget = Number(vpp8.defaultBatTarget ?? 0);\n const defaultExec = Number(vpp8.defaultExecDuration ?? 600);\n const defaultNext = Number(vpp8.defaultNextMotion ?? 160);\n\n // TargetSetType (1=reset, 2=update)\n let targetSetType = await this._getDpStateNumber(targetSetTypeDpId);\n if (!Number.isFinite(targetSetType) || targetSetType <= 0) targetSetType = defaultTargetSetType;\n targetSetType = Math.round(targetSetType);\n if (targetSetType < 1) targetSetType = 1;\n if (targetSetType > 2) targetSetType = 2;\n\n const isPvTrigger = (currentDpId === pvTargetDpId);\n const isBatTrigger = (currentDpId === batTargetDpId);\n\n // PV Power target is an U32 (W). If PV is not the trigger, take the last known PV target state.\n // If none is available (never written), fall back to a template default.\n let pvWTarget;\n if (isPvTrigger) {\n pvWTarget = Math.round(Number(raw) || 0);\n } else {\n pvWTarget = await this._getDpStateNumber(pvTargetDpId);\n if (!Number.isFinite(pvWTarget)) pvWTarget = defaultPvTarget;\n pvWTarget = Math.round(Number(pvWTarget) || 0);\n }\n if (!Number.isFinite(pvWTarget)) pvWTarget = 0;\n if (pvWTarget < 0) pvWTarget = 0;\n // clamp to uint32 range (practically never reached)\n if (pvWTarget > 0xFFFFFFFF) pvWTarget = 0xFFFFFFFF;\n\n // Battery power target is an S32 (W) (+ discharge / - charge).\n // If BAT is the trigger, use the written value, otherwise take the last known BAT target state.\n let batWTarget;\n if (isBatTrigger) {\n batWTarget = Math.round(Number(raw) || 0);\n } else {\n batWTarget = await this._getDpStateNumber(batTargetDpId);\n if (!Number.isFinite(batWTarget)) batWTarget = defaultBatTarget;\n batWTarget = Math.round(Number(batWTarget) || 0);\n }\n if (!Number.isFinite(batWTarget)) batWTarget = defaultBatTarget;\n if (batWTarget < -0x80000000) batWTarget = -0x80000000;\n if (batWTarget > 0x7FFFFFFF) batWTarget = 0x7FFFFFFF;\n\n // ExecDuration (seconds)\n let execDuration = await this._getDpStateNumber(execDpId);\n if (!Number.isFinite(execDuration) || execDuration <= 0) execDuration = defaultExec;\n execDuration = Math.round(execDuration);\n if (execDuration < 0) execDuration = 0;\n if (execDuration > 0xFFFF) execDuration = 0xFFFF;\n\n // NextMotion (U16)\n let nextMotion = await this._getDpStateNumber(nextDpId);\n if (!Number.isFinite(nextMotion) || nextMotion <= 0) nextMotion = defaultNext;\n nextMotion = Math.round(nextMotion);\n // Valid values per VPP protocol: 0x00A0 (exit VPP) or 0x00A1 (switch to default VPP mode 6)\n if (nextMotion !== 0x00A0 && nextMotion !== 0x00A1) nextMotion = defaultNext;\n\n // Build register block:\n // [VPPModeNum, TargetSetType, PvWTarget_L/H, BatWTarget_L/H, ExecDuration, NextMotion]\n const blockRegs = [];\n blockRegs.push(...bufferToRegs(valueToBuffer(modeNum, 'uint16', 2), wo, bo));\n blockRegs.push(...bufferToRegs(valueToBuffer(targetSetType, 'uint16', 2), wo, bo));\n blockRegs.push(...bufferToRegs(valueToBuffer(pvWTarget, 'uint32', 4), wo, bo));\n blockRegs.push(...bufferToRegs(valueToBuffer(batWTarget, 'int32', 4), wo, bo));\n blockRegs.push(...bufferToRegs(valueToBuffer(execDuration, 'uint16', 2), wo, bo));\n blockRegs.push(...bufferToRegs(valueToBuffer(nextMotion, 'uint16', 2), wo, bo));\n\n const blockAddr = this._addr({ address: startAddress });\n await this._mbWriteRegisters(blockAddr, blockRegs, unitId);\n return;\n }\n\n\n // --- Special case: FoxESS Remote Control requires a single FC16 multi-write starting at 46001 ---\n // FoxESS H3 remote control uses:\n // - 46001: Remote Control (bitfield16)\n // - 46002: Remote Timeout Set (s)\n // - 46003..46004: Remote Control Active Power Command (S32, W)\n // Writing only 46003 may be ignored unless 46001/46002 are set accordingly.\n const frc = this._foxessRemoteControl;\n const frcTriggerId = (frc && frc.triggerDpId) ? String(frc.triggerDpId) : 'sET_ACTIVE_POWER';\n if (\n fc === 16 &&\n frc && frc.enabled === true &&\n String(dp?.id) === frcTriggerId\n ) {\n const startAddress = Number(frc.startAddress ?? 46001);\n const timeoutDpId = (frc.timeoutDpId || 'rEMOTE_TIMEOUT_SET').toString();\n const defaultTimeout = Number(frc.defaultTimeout ?? 600);\n\n // Remote Control bitfield\n // bit0: enable (1)\n // bit1: positive direction (0 = power-generation system, 1 = power-consumption system)\n // bits3:2: controlled target (01 = Battery)\n const enable = Number(frc.enable ?? 1) ? 1 : 0;\n const positiveDirection = Number(frc.positiveDirection ?? 0) ? 1 : 0;\n const target = Number(frc.target ?? 1) & 0x03;\n\n let remoteControlWord = 0;\n if (enable) remoteControlWord |= 1;\n if (positiveDirection) remoteControlWord |= 2;\n remoteControlWord |= (target << 2);\n\n // Timeout (seconds) - allow override via existing datapoint state\n let timeout = await this._getDpStateNumber(timeoutDpId);\n if (!Number.isFinite(timeout) || timeout < 0) timeout = defaultTimeout;\n timeout = Math.round(timeout);\n if (timeout < 0) timeout = 0;\n if (timeout > 0xFFFF) timeout = 0xFFFF;\n\n // Active power command (S32, W) - ensure integer\n const powerW = Math.round(Number(raw) || 0);\n\n // Build register block: [RemoteControl, TimeoutSet, ActivePowerCmd_L/H]\n const blockRegs = [];\n blockRegs.push(...bufferToRegs(valueToBuffer(remoteControlWord, 'uint16', 2), wo, bo));\n blockRegs.push(...bufferToRegs(valueToBuffer(timeout, 'uint16', 2), wo, bo));\n blockRegs.push(...bufferToRegs(valueToBuffer(powerW, 'int32', 4), wo, bo));\n\n const blockAddr = this._addr({ address: startAddress });\n await this._mbWriteRegisters(blockAddr, blockRegs, unitId);\n return;\n }\n\n const words = Number(src.length || 1);\n\n // Alfen ACE EMS control: keep the official document-register-minus-one\n // layout as the canonical first attempt, but retry the direct table-address\n // layout only after exact Modbus exception 2. This must run before the\n // generic repeatEncodedValue helper so the SCN three-phase block is handled\n // by the same compatibility logic as the socket current command.\n if ((fc === 6 || fc === 16) && this._isAlfenProfile && this._alfenControlKindForDpId(dp && dp.id)) {\n if (await this._writeAlfenControlAdaptive(dp, src, addr, raw, words, unitId, wo, bo, setWriteContext)) return;\n }\n\n // Generic helper for Modbus profiles where one engineering value must be\n // written repeatedly as a multi-register data type. Example: Alfen SCN max\n // current uses one FLOAT32 per phase and must refresh L1/L2/L3 in one FC16\n // request (6 registers total, 2 words per FLOAT32).\n if (fc === 16 && words > 1 && (src.repeatEncodedValue === true || src.repeatEncodedToLength === true || src.repeatDataTypeValue === true)) {\n const oneWordsRaw = Number(src.repeatValueWords ?? src.valueWords ?? dataTypeWordLength(src.dataType));\n const oneWords = Number.isFinite(oneWordsRaw) && oneWordsRaw > 0 ? Math.trunc(oneWordsRaw) : dataTypeWordLength(src.dataType);\n if (oneWords <= 0 || words % oneWords !== 0) {\n throw new Error(`Invalid repeatEncodedValue layout for ${dp?.id || 'datapoint'}: length=${words}, valueWords=${oneWords}`);\n }\n const singleBuf = valueToBuffer(raw, src.dataType, oneWords * 2);\n const singleRegs = bufferToRegs(singleBuf, wo, bo);\n if (!singleRegs.length) throw new Error(`Cannot encode repeatEncodedValue for ${dp?.id || 'datapoint'}`);\n const regsToWrite = [];\n const repeatCount = Math.trunc(words / singleRegs.length);\n for (let i = 0; i < repeatCount; i++) regsToWrite.push(...singleRegs);\n const offsets = this._addressFallbackOffsets(src);\n const addresses = [addr];\n for (const off of offsets) {\n const a = Number(addr) + Number(off);\n if (Number.isFinite(a) && a >= 0 && !addresses.includes(a)) addresses.push(a);\n }\n let lastErr = null;\n for (const a of addresses) {\n try {\n setWriteContext(src, fc, a, raw, words, unitId);\n await this._mbWriteRegisters(a, regsToWrite.slice(0, words), unitId);\n this._logAlfenAcceptedControlWrite(dp, src, unitId, fc, a, raw, regsToWrite.slice(0, words));\n return;\n } catch (e) {\n lastErr = e;\n if (!isModbusIllegalAddressOrValue(e)) throw e;\n }\n }\n throw lastErr;\n }\n\n // Generic helper for Modbus profiles where one user-facing setpoint must be\n // written into several consecutive registers with the same value. Example:\n // Mennekes charging-point-network EMS current limit L1/L2/L3 (registers 613..615).\n if (fc === 16 && words > 1 && (src.repeatValue === true || src.repeatToLength === true || src.fillRegisters === true)) {\n const singleBuf = valueToBuffer(raw, src.dataType, 2);\n const singleRegs = bufferToRegs(singleBuf, wo, bo);\n const one = singleRegs.length ? singleRegs[0] : 0;\n const regsToWrite = Array(words).fill(one);\n const offsets = this._addressFallbackOffsets(src);\n const addresses = [addr];\n for (const off of offsets) {\n const a = Number(addr) + Number(off);\n if (Number.isFinite(a) && a >= 0 && !addresses.includes(a)) addresses.push(a);\n }\n let lastErr = null;\n for (const a of addresses) {\n try {\n setWriteContext(src, fc, a, raw, words, unitId);\n await this._mbWriteRegisters(a, regsToWrite, unitId);\n return;\n } catch (e) {\n lastErr = e;\n if (!isModbusIllegalAddressOrValue(e)) throw e;\n }\n }\n throw lastErr;\n }\n\n const buf = valueToBuffer(raw, src.dataType, words * 2);\n const regs = bufferToRegs(buf, wo, bo);\n\n const fallbackAddresses = (() => {\n const offsets = this._addressFallbackOffsets(src);\n const out = [addr];\n for (const off of offsets) {\n const a = Number(addr) + Number(off);\n if (Number.isFinite(a) && a >= 0 && !out.includes(a)) out.push(a);\n }\n return out;\n })();\n\n if (fc === 6) {\n if (regs.length < 1) throw new Error('FC6 requires one register');\n let lastErr = null;\n for (const a of fallbackAddresses) {\n try {\n setWriteContext(src, fc, a, raw, 1, unitId);\n await this._mbWriteRegister(a, regs[0], unitId);\n return;\n } catch (e) {\n lastErr = e;\n if (!isModbusIllegalAddressOrValue(e)) throw e;\n }\n }\n throw lastErr;\n }\n\n if (fc === 16) {\n let lastErr = null;\n for (const a of fallbackAddresses) {\n try {\n setWriteContext(src, fc, a, raw, words, unitId);\n await this._mbWriteRegisters(a, regs, unitId);\n return;\n } catch (e) {\n lastErr = e;\n if (!isModbusIllegalAddressOrValue(e)) throw e;\n }\n }\n throw lastErr;\n }\n\n throw new Error(`Unsupported write FC=${fc}`);\n };\n\n try {\n return await attempt();\n } catch (e) {\n // Transport errors are often recoverable by forcing a reconnect and retrying once.\n if (isTransportError(e)) {\n this._markDisconnected(e);\n try {\n return await attempt();\n } catch (e2) {\n if (isTransportError(e2)) {\n this._markDisconnected(e2);\n }\n throw annotateWriteError(e2);\n }\n }\n throw annotateWriteError(e);\n }\n }\n}\n\nmodule.exports = { ModbusDriver };\n","usedDeprecatedRules":[]}]
@@ -0,0 +1,22 @@
1
+ 'use strict';
2
+ const net=require('node:net');
3
+ const assert=require('node:assert/strict');
4
+ const root='/workspace/scratch/741f792566ea/source-919/iobroker.eos-admin';
5
+ const {ModbusDriver}=require(root+'/modules/devices/lib/drivers/modbus');
6
+ const {guardDriver}=require(root+'/modules/devices/operation-guard');
7
+ const template=require(root+'/modules/devices/lib/templates.json').templates.find(t=>t.id==='ess.solax.SolaXHybridX1X3Ess');
8
+ (async()=>{
9
+ const accepted=[]; const server=net.createServer(socket=>accepted.push(socket));
10
+ await new Promise((resolve,reject)=>{server.once('error',reject);server.listen(0,'127.0.0.1',resolve)});
11
+ const logs=[]; let allowed=true;
12
+ const driver=guardDriver(new ModbusDriver({log:Object.fromEntries(['info','debug','warn','error'].map(k=>[k,v=>logs.push(v)]))},{id:'audit',protocol:'modbusTcp',connection:{host:'127.0.0.1',port:server.address().port}},template,{}),()=>allowed);
13
+ driver._nextConnectAt=Date.now()+350;
14
+ const started=driver.connect().then(()=>({resolved:true}),e=>({rejected:e.code||e.message}));
15
+ await new Promise(resolve=>setTimeout(resolve,30));
16
+ allowed=false; await driver.disconnect();
17
+ const stoppedAt=Date.now();
18
+ const result=await started;
19
+ console.log(JSON.stringify({result,connectionsAfterConfirmedStop:accepted.length,driverConnected:driver.connected,hasClient:!!driver.client,elapsedAfterStop:Date.now()-stoppedAt,logs}));
20
+ await driver.disconnect(); for(const socket of accepted)socket.destroy(); await new Promise(resolve=>server.close(resolve));
21
+ assert.equal(accepted.length,0,'A stopped/unauthorized hosted driver must not open a new TCP connection after its reconnect backoff');
22
+ })().catch(e=>{console.error(e);process.exitCode=1});