iobroker.digitalstrom 2.2.1 → 3.0.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/README.md CHANGED
@@ -11,49 +11,146 @@
11
11
 
12
12
  **This adapter uses Sentry libraries to automatically report exceptions and code errors to the developers.** For more details and for information how to disable the error reporting see [Sentry-Plugin Documentation](https://github.com/ioBroker/plugin-sentry#plugin-sentry)! Sentry reporting is used starting with js-controller 3.0.
13
13
 
14
+ **Deutsche Version: [README_de.md](README_de.md)**
15
+
14
16
  ## Digitalstrom adapter for ioBroker
15
17
 
16
- Support for Digitalstrom devices via DSS
18
+ Support for digitalSTROM devices via DSS
19
+
20
+ > Since version 2.4 the adapter has been substantially reworked: the original library layer was
21
+ > replaced, the admin dialog was rebuilt from scratch, the modern Smart Home API of the dSS is used
22
+ > alongside the classic interface and a large number of runtime bugs were fixed.
23
+ > See the changelog for details.
17
24
 
18
25
  ## Installation
19
26
 
20
- Please install the adapter via Admin UI as usual.
27
+ Install the adapter from the adapter list in Admin. The current development state can be installed
28
+ with `iobroker url https://github.com/ioBroker/ioBroker.digitalstrom` on the command line.
29
+
30
+ Requirements: Node.js 22 or newer, js-controller 6.0.11 or newer and Admin 7.6.17 or newer. The
31
+ object warning limit on the settings tab needs js-controller 7.1.0 or newer.
32
+
33
+ ## Two interfaces, one team
34
+
35
+ A digitalSTROM server offers two interfaces, each with its own strengths - and this adapter
36
+ deliberately uses both as a team:
37
+
38
+ * The **classic interface** (app token) is the adapter's base access: button presses, sensor
39
+ values and binary inputs arrive as **events in real time**, and **every switching command**
40
+ runs through it.
41
+ * The **Smart Home API** (`/api/v1`, dSS firmware 1.19 or newer) is the reading turbo:
42
+ **all meter values and all device output values** (brightness, blind positions, colour values)
43
+ arrive bundled in **one single request each** instead of one request per value. On top it
44
+ delivers the room temperature setpoints of every zone, the scene names given in digitalSTROM,
45
+ and a change-notification websocket the adapter uses to reconcile values that were changed
46
+ past ioBroker - for example by a third-party app. A travelling blind carries no value in it,
47
+ but it carries its whole journey, so the position is computed and follows the movement live.
48
+
49
+ **Both are opened by the same credential**: the app token from the setup. The Smart Home API
50
+ needs no second key - a separate API key stays available as an option, and is used first when one
51
+ is configured.
52
+
53
+ Together this means: the adapter **starts in seconds instead of minutes** even on large
54
+ installations, values are fresh again quickly after scene calls, and the dSS carries noticeably
55
+ less load, comfortably within the digitalSTROM request guidelines. All of it at full reliability:
56
+ every Smart Home API task falls back to the classic path automatically, so the adapter stays
57
+ completely functional with just the classic interface.
58
+
59
+ The **status tab** of the instance settings shows this division of labour live - which interface
60
+ currently delivers events, meter values and output values, and how much each of them actually did
61
+ in the last 10 minutes:
62
+
63
+ ![Status tab: the division of labour between the two interfaces, live](docs/admin-status.png)
64
+
65
+ ## Configuration
66
+
67
+ The connection tab walks through the setup: the server address (entered once - it serves both
68
+ interfaces), the app token as the base access (created directly from the dialog with your dSS
69
+ credentials, which are not stored - the instance has to be running for this), and a switch for the
70
+ recommended acceleration. **The app token
71
+ opens both interfaces**, so the Smart Home API needs no second credential - a separate API key
72
+ stays available as an option behind a link:
73
+
74
+ ![Connection tab of the configuration dialog](docs/admin-connection.png)
75
+
76
+ The polling interval, the behaviour of the adapter and the object warning limit sit on the settings tab:
77
+
78
+ ![Settings tab of the configuration dialog](docs/admin-settings.png)
21
79
 
22
- As soon as the adapter is officially released he will be in the repo and simply selectable.
80
+ The notes tab summarizes the "why two interfaces?" story and the certificate note right inside
81
+ the dialog:
23
82
 
24
- During test phase, or for testing of newer versions (see relevant forum threads) you can also install the adapter directly from GitHub using https://github.com/ioBroker/ioBroker.digitalstrom as URL. Please use the Admin "Custom Install" option for this.
83
+ ![Notes tab of the configuration dialog](docs/admin-notes.png)
25
84
 
26
- ## Usage
85
+ Additionally to the connection settings you can edit the following settings to your needs:
27
86
 
28
- After installing the adapter and creating an instance the admin dialog will appear.
29
- First of all you need to enter your DSS IP/Hostname. Then you can choose if you already have manually created an App Token in the DSS Web-Interface or not.
30
- If you do not have an App-Token simply enter your Username and Password to retrieve an App Token automatically.
87
+ * **Read meter and output values through the Smart Home API**: One request serves all circuits,
88
+ one status request all device outputs. Needs a dSS with firmware 1.19 or newer - and nothing
89
+ else: the app token opens this interface as well. Safe to enable: whenever the Smart Home API
90
+ does not answer, the classic path takes over automatically and the adapter keeps running
91
+ unchanged. The switch is off for a new instance - switch it on in step 3 of the connection tab.
92
+ * **Data Polling Interval**: How often, in seconds, the power and energy values of your circuits (dSMs) are read. Default 100s, minimum 60s: a value between 0 and 60 is raised to 60s, 0 switches polling of the meter values off completely, and a value that is not a number falls back to the default. Why 100s: the digitalSTROM rules 8 and 9 allow at most one cyclic read per minute and circuit. On the classic interface one cycle reads two values per circuit (`getConsumption` and `getEnergyMeterValue`), and the next cycle only starts once they are answered, so a cycle takes about 20s longer than the configured interval - measured against a real DSS: 60s results in ~1.5 requests per minute and circuit, 100s in exactly 1.0. Lower values stay possible from 60s on, but they exceed the guideline. With the Smart Home API switched on, one single request per cycle reads the values of all circuits.
93
+ * **Use Scene Preset Values**: digitalSTROM works mainly with scenes, and for lights and blinds many scenes have a known output value. When this option is on and a scene is called, the adapter writes that preset value to the output states right away; the real values are read shortly afterwards (as long as **Actively request Device Output values** is on). With the Smart Home API switched on, blinds do not use the preset: as long as the output values are requested, their real position follows the movement instead. A preset can differ from the real value, for example when a local priority is set on a device.
94
+ * **Actively request Device Output values**: The adapter reads the output values of all devices at start and again after scenes that affect a device. With the Smart Home API switched on this is one bundled status request; without it the values are read individually through the classic interface, and these requests go over the digitalSTROM bus. If that is a problem in your installation, switch the option off - the output states are then no longer read from the DSS. This option only controls **reading** output values from the DSS - writing (e.g. setting a blind position or angle, or a dimmer value) always works, independent of this setting.
95
+ * **Delete unknown objects on startup**: When enabled, all ioBroker objects that are not part of the current DSS structure are deleted on adapter startup. Warning: Objects of devices that are just temporarily unreachable (e.g. a powered-off circuit) are deleted too - including their custom settings like history/InfluxDB configurations! Because of that this option is disabled by default; orphaned objects are then only listed in the log.
96
+ * **Validate TLS certificate of the DSS**: By default the certificate of the DSS is not validated because the DSS uses a self-signed certificate. Only enable this if your DSS has a valid certificate. See the security note below.
31
97
 
32
- Additionally to the Authentication settings (see above) you can edit the following settings to your needs:
33
- * **Data Polling Interval**: This is the interval the "Energy Meter" data are requested from your DSM devices. Default 60s. You can set 0 if you do not want to poll the Engerymeter data.
34
- * **Use Scene Preset Values**: The Digitalstrom system is not really designed to have the real output values of the devices available all the time and works most with Scenes. For Light and Shader/Blinds some output values are defined for many of the available Scenes. The adapter knows them and when this setting is active the adapter will try to lookup these values when a scene gets triggered and set those values to the states directly. The real values are requested with a delay. This method might deliver wrong values when local priorities are set/used!
35
- * **Request Device Output values actively**: The adapter initializes all device output values on start and also after scenes that are effective for a device. There are delay but in fact all those messages will go over the Digitalstrom bus. If this is problematic for you you can try to deactivate this feature.
98
+ After you have saved the settings with an app token, the adapter restarts automatically. It reads
99
+ the structure of your installation (floors, rooms, groups, circuits and devices) and creates the
100
+ ioBroker objects for it. Depending on the size of the installation and the performance of your
101
+ system this takes a while - several thousand objects are quickly reached, so please give the adapter
102
+ time. It already listens to the dSS events while it builds the objects (see the behaviour notes).
36
103
 
37
- After providing an App token and saving the settings the adapter will restart automatically.
104
+ As soon as the status light of the instance is green and the log shows "Subscribed to states ...",
105
+ everything is ready and you can e.g.:
38
106
 
39
- When data are correct the adapter read out the apartment and devices structure and create them as ioBroker Objects. This can take some time (depending on the number of devices and floors/zones/groups and the performance of your system several seconds). Please be patient. And I really mean it that way ... Several thousand objects are easy to reach here! Give the adapter time please!
107
+ * call or undo scenes for the apartment, rooms, groups or devices
108
+ * read states and sensor values; for rooms you can also push sensor values
109
+ * see the values of binary inputs, sensors, buttons and outputs
40
110
 
41
- After this the adapter subscribes to several DSS Events to get notified about actions in the system.
111
+ ### Object warning limit
42
112
 
43
- The adapter status light will get green and you will see "Subscribed to states ..." as info log. After this everything is ready and you can e.g.:
44
- * set/undo scenes for apartment, zones, groups or devices
45
- * read state and sensor values; for zones it is also possible to push sensor values
46
- * see the values for Binary inputs, Sensors, Buttons and Outputs
113
+ ioBroker (js-controller 7.1.0 or newer) warns when an instance has **more objects than its object warning
114
+ limit**. A digitalSTROM installation easily has several thousand objects, so this adapter suggests a limit of
115
+ 10000. Instances that existed before often still have 5000 - with more objects than that, ioBroker warns at
116
+ every start although nothing is wrong.
117
+
118
+ The card **Object warning limit** on the settings tab shows the limit that is set, the adapter default and the
119
+ state. To change it, enter a whole number such as `10000` and press **Save**:
120
+
121
+ ![Changing the object warning limit](docs/admin-warnlimit-save.png)
122
+
123
+ Good to know:
124
+
125
+ * The limit only controls the warning. It does not create, delete or hide objects, and it makes neither
126
+ digitalSTROM nor ioBroker slower or faster.
127
+ * The new limit applies from the **next start** of the instance. Saving the limit alone does not restart it.
128
+ * A warning that is already shown is not taken back automatically - acknowledge it in Admin under **Hosts**.
129
+ * A good value is a little above the real number of objects, which the warning in the log names
130
+ ("This instance has ... objects").
131
+
132
+ ### Security note about the TLS certificate check
133
+
134
+ The option **Validate TLS certificate of the DSS** is disabled by default and stays disabled - a digitalSTROM server ships with a self-signed certificate, so enabling validation by default would break every existing installation.
135
+
136
+ What that means: the connection to the DSS is encrypted, but the adapter does not verify *who* it is talking to. In a local network that you control this is usually acceptable. An attacker who can redirect traffic inside your network (ARP spoofing, a compromised router, an untrusted WLAN) could however place himself between ioBroker and the DSS and would then see the App-Token and every command.
137
+
138
+ Recommendations, in this order:
139
+
140
+ 1. Keep the DSS and ioBroker in a trusted, separated network segment and do not route the DSS connection over the internet or an untrusted WLAN.
141
+ 2. If your DSS has a certificate from a public CA (e.g. behind a reverse proxy with a valid certificate), or from your own CA that Node.js on the ioBroker host already trusts (for example through the environment variable `NODE_EXTRA_CA_CERTS`), enter the host name the certificate was issued for and enable the option.
142
+ 3. Migration path if you want validation with the original self-signed certificate: this needs the certificate itself. The adapter currently supports neither a custom CA file nor a certificate fingerprint - both would be possible technically (`ca` / `checkServerIdentity` of the Node.js TLS agent) and are noted as a possible future enhancement. Until then option 1 or 2 is the way to go.
143
+
144
+ The App-Token is stored encrypted (`encryptedNative`), is not passed on to other adapters (`protectedNative`), is not written to the log and is shown masked in the admin dialog. The same applies to the optional Smart Home API key.
47
145
 
48
146
  ## State and Object structure
49
147
 
50
148
  The adapter provides two data structures. The Apartment structure with Floors, Zones (Rooms) and Groups and additionally the structure of Circuits/dSMs and the connected devices with their detail data.
51
149
 
52
150
  In the structures several "types" of data are included:
53
- * Scenes: Scenes are implemented as switches. Setting the value tro "true" will send a "callScene" command for this scene. A value of "false" will send an "undoScene" command for this scene - it is up the the DSS server to decide if "undo" is a valid command! When a callScene or undoScene is triggered as event from the DSS server the relevant scene is set to "true" or "false" with ack=true
54
- * States: States from the system and user defined states via the addon are shown and are read only
55
- * Sensor values are updated when triggered by an event and can partially also bet changed - changes are send a "pushSensorValue" to the server and it is up to the server if the value is accepted! This is mainly relevant for Temperature or Humidity values
56
- *
151
+ * Scenes: Scenes are implemented as switches. Setting the value to "true" will send a "callScene" command for this scene. A value of "false" will send an "undoScene" command for this scene - it is up to the DSS server to decide if "undo" is a valid command! When a callScene or undoScene is triggered as event from the DSS server the relevant scene is set to "true" or "false" with ack=true. Scenes that command a movement instead of selecting a position (Stop, Increment, Decrement, Area Stepping Continue, Impulse) fall back to "false" on their own, see the behaviour notes
152
+ * States: the states of the system are shown and are read only. The user defined states of the apartment (`apartment.userStates`) can also be set - the new value is forwarded to the DSS
153
+ * Sensor values are updated when triggered by an event. Most sensor values of a zone can also be written: the new value is sent to the server as "pushSensorValue", and it is up to the server whether it accepts the value! This is mainly relevant for Temperature or Humidity values
57
154
 
58
155
  ### Apartment object and states
59
156
  ![Apartment Objects](img/dss-apartment.png)
@@ -61,7 +158,7 @@ In the structures several "types" of data are included:
61
158
  For the Apartment a structure with "floor"."zone" is created with the following substructures inside this:
62
159
  * per device group a sub folder is created including the available group scenes
63
160
  * scenes for this zone
64
- * states for this zone
161
+ * states for this zone, in rooms the climate control cools passively also the read-only `passiveCooling`
65
162
  * sensor values for this zone
66
163
 
67
164
  On Apartment level all device groups are available with it's scenes.
@@ -74,24 +171,700 @@ On Apartment level also Sensors (also outdoor values), States and user states ar
74
171
  The devices are structured with "circuit/dSM"."deviceID" and the subsctructure inside includes:
75
172
  * Device Scenes, will be triggered for this device only
76
173
  * Device Sensors, when reported from the system. So values might be empty
77
- * Output values (e.g. state/brightness for Lights and position/angle for Shades/Blinds) are located directly below the device. Only Lights and Shades/Blinds will have a defined functionality for now.
174
+ * Output values (e.g. state/brightness for Lights and position/angle for Shades/Blinds) are located directly below the device. digitalSTROM Lights and Shades/Blinds carry the full named functionality; a Joker (Black) with an output - a switched socket, for instance - has its output value read as well, and vDC devices (Hue, Sonos) reach their channels through the named channel read. Device sensors and output channels without a write path are read-only - for instance all channels of a multi-channel vDC light (Hue colour and colour-temperature lamps, brightness included) and the Sonos channels.
78
175
  * Buttons and Binary Inputs will also be represented by states and are read only
79
176
 
177
+ ## Behaviour notes
178
+
179
+ * **Fast consecutive writes**: If a new value is written to the same output while an older value is still waiting in the request queue, the older one is replaced (last write wins) to respect the DSS request rate limits. The replaced request is reported as "superseded" and its value is never acknowledged as written. A write that is already sent to the DSS is never replaced - the newer value is sent afterwards.
180
+ * **Host field**: IP addresses, DNS names, full URLs and IPv6 addresses (in brackets) are accepted. Without an explicit port 8080 is used. Credentials, paths or query strings in the host field are rejected.
181
+ * **A travelling output**: while a blind moves, the dSS reports no value, but it announces the journey - where it started, where it goes and the window it takes. The position is computed from that during the travel and follows the movement. In the moment the announced end passes nothing is written, so the state never claims the target before the blind is there; the real value follows within about two seconds.
182
+ * **User states**: a user state is only forwarded to the dSS when its value really changes, so a script that re-asserts the same value every few minutes causes no requests at all. The value the dSS reports is tracked from both directions, so a state someone changed in the dSS is never mistaken for unchanged.
183
+ * **Momentary scenes and button presses**: Stop, Increment, Decrement, Area Stepping Continue and Impulse are commands, not positions - the dSS sends a callScene for them and never the undoScene that would release it again. Their `scenes.<name>` therefore goes true and falls back to false half a second later, so a rule on it fires on every press instead of only on the first one ever. A repeat within that half second re-arms the release rather than adding a second edge, because a wall switch repeats its Stop. `scenes.sceneId` is not released and keeps answering which scene was called last. `<device>.<n>.button` follows the same rule for the same reason: the dSS reports a press and never takes it back, so it goes true and falls back half a second later. `buttonClickType` and `buttonHoldCount` are not released - they describe the press that happened, not the moment.
184
+ * **The first two minutes after a start**: the adapter subscribes to the dSS events before it has created its objects, so almost nothing is lost while a large installation is being built. Sensor values, states and binary inputs that arrive in that window are applied once the objects exist, on top of the initial snapshot. Scene calls and button presses in that window are deliberately NOT caught up - acting on a press minutes after it happened would be worse than missing it. The last called scene of every ZONE GROUP is re-read at the end of the start, so a group scene missed there is corrected; a scene the dSS reported for a single device is not, and stays as it was until the next call reaches it.
185
+ * **A state the dSS does not know**: the dSS reports some on/off states, for example the room state `heating`, as "unknown" as long as it has no information. Where the adapter shows such a state as true/false, it has no value (null) until the dSS reports active or inactive; a state that keeps the wording of the dSS, such as a user state or a device state, shows the word "unknown". Writing null into a state sends nothing to the dSS.
186
+ * **A dSS that cannot be reached**: when the dSS does not answer at startup (for example while it restarts, installs an update or the network is down), the adapter keeps running and asks again every 5 minutes instead of restarting itself. The first failed check is logged as an error that says what to check. Further checks are only logged at debug level, and a different error is reported once more. One info line tells when the dSS answers again and how long it could not be reached, then the start continues. Until then `info.connection` stays false. A dSS that answers but refuses the App-Token is reported as a refused login, with the hint to check the token, and is asked again in the same way.
187
+
80
188
  ## Known Issues / System design effects
81
- * The DSS system mainly works using scenes and not via real device values and also getting the real values is very slow because needs to be fetched via the bus.
189
+ * The digitalSTROM system is scene-centric by design: most actions are scene calls rather than
190
+ individual value writes, and the adapter mirrors that model. With the Smart Home API enabled,
191
+ the real output values additionally arrive bundled in one status request, so they stay fresh
192
+ without extra bus traffic.
82
193
  * Values might be empty when they were not reported by the system
83
- * Binary inputs were implemented "Blind" right know because I do not have such a devices. So I'm happy to get some logs/reports with binary input devices :-)
84
- * Meaningful output value reading and writing is only implemented for Ligh (Yellow) and Shade/Blind (Gray) devices.
85
- * I had no chance so far checking how the system behaves with vDCs. So I need logs and details here to add it
86
- * Ventilation and Temperature management/devices are also not fully implemented ... what makes sense here?
194
+ * Binary inputs were originally implemented without any hardware to test against. They are confirmed to work in the meantime, with motion detectors and window handles reporting through them. The state keeps the number the DSS reports, so history data stays comparable, but the numbers are named: `inactive`/`active` for a normal binary input, and `closed`/`open`/`tilted` for a window handle, which reports three positions instead of two.
195
+ * The full named output functionality - brightness, position and angle - is implemented for
196
+ digitalSTROM Light (Yellow, GE-) and Shade/Blind (Gray, GR-) devices, and a vDC light with a single
197
+ output channel (a dimmable Hue lamp such as the LWV001) takes a brightness value as well. A vDC
198
+ light with several channels (Hue colour and colour-temperature lamps) is read in all its channels,
199
+ brightness included, and is switched and dimmed through its scenes. Of a blind with indoor and
200
+ outdoor channels (GR-KL300) only the outdoor position and angle can be set. A Joker (Black) with an
201
+ output is read as well and follows its scenes, but its value stays the plain, read-only output
202
+ value without a named meaning.
203
+ * vDC devices (Hue lamps, Sonos players) read their output channels through the named read
204
+ `device/getOutputChannelValue2` - verified against a dSS20 1.19.13. The audio volume and power
205
+ state of Sonos players and the colour values of vDC lights arrive with and without the Smart Home
206
+ API, and a dSS that rejects the call for a device is remembered per device. Beyond their output
207
+ channels there is no vDC-specific handling, so logs and reports about other vDC hardware are still
208
+ welcome.
209
+ * Room temperature control is implemented for the rooms the DSS really regulates: the controller mode and the controller state are read, the operation mode follows the scenes of group 48 and can be set, and the set point of every operation mode is read and writable. Rooms without an active controller deliberately get no such objects.
210
+ * Ventilation is covered by the group scenes, the apartment ventilation status and the two boolean output channels (swing mode, auto intensity). Ventilation devices have no dedicated functionality beyond that, because no such hardware was available to test against. Logs and reports are welcome.
211
+ * If the configuration dialog shows up only as a narrow strip of about 150 px under the title, update
212
+ Admin: Admin 8.0.11 displayed adapter dialogs like this one that way, Admin 8.0.15 shows them
213
+ normally again.
87
214
 
88
215
  ## How to report issues and feature requests
89
216
 
90
- Please use GitHub issues for this.
217
+ Please use [GitHub issues](https://github.com/ioBroker/ioBroker.digitalstrom/issues) for this.
218
+
219
+ Best is to set the adapter to Debug log mode (Instances -> Expert mode -> Column Log level). Then please get the logfile from disk (subdirectory "log" in ioBroker installation directory and not from Admin because Admin cuts the lines). Please add a reference to the relevant GitHub issue AND also describe what should be seen in the log at which time.
220
+
221
+ ## Credits and license
222
+
223
+ This adapter was originally written by **Apollon77 &lt;iobroker@fischer-ka.de&gt;** and published under the
224
+ MIT license at [ioBroker/ioBroker.digitalstrom](https://github.com/ioBroker/ioBroker.digitalstrom).
225
+ All credit for the original work belongs to him.
91
226
 
92
- Best is to set the adapter to Debug log mode (Instances -> Expert mode -> Column Log level). Then please get the logfile from disk (subdirectory "log" in ioBroker installation directory and not from Admin because Admin cuts the lines). If you do not like providing it in GitHub issue you can also send it to me via email (iobroker@fischer-ka.de). Please add a reference to the relevant GitHub issue AND also describe what I see in the log at which time.
227
+ The rework from version 2.4.0 on was done by André Schmitz (2026). It is published under the same
228
+ MIT license; the original copyright notice is kept unchanged in [LICENSE](LICENSE).
93
229
 
94
230
  ## Changelog
231
+ <!--
232
+ Placeholder for the next version (at the beginning of the line):
233
+ ### **WORK IN PROGRESS**
234
+ -->
235
+ ### 3.0.0 (2026-11-27)
236
+
237
+ * The maintained fork (https://github.com/mrandreschmitz/ioBroker.digitalstrom) was brought back
238
+ into this repository. Repository URLs point here again, the Sentry plugin is configured again,
239
+ and the release workflow publishes to npm again
240
+ * (GermanBluefox) Updating from 2.3.0 keeps the App-Token: 2.3.0 stored it in plain text, it is now
241
+ taken over and stored encrypted automatically instead of having to be entered again
242
+ * (GermanBluefox) Removed the development scripts under `scripts/` that were only used to explore the
243
+ Smart Home API (they were not part of the package)
244
+ * (GermanBluefox) The adapter was refactored to TypeScript: the sources are in `src/` and are compiled to
245
+ `build/`, `tasks.ts` builds the backend and the admin interface, the tests use `node:assert` instead of
246
+ chai, and the workflow uses the ioBroker testing actions with npm trusted publishing
247
+ * (GermanBluefox) Installing the adapter directly from GitHub is no longer possible (`common.nogit`), because the
248
+ package has to be built first. Install it from npm as usual
249
+ * (GermanBluefox) When the dSS answers a structure request without an error text, the log now shows its answer
250
+ instead of "[object Object]"
251
+
252
+ ### 2.4.27 (2026-10-09)
253
+
254
+ * **Names the dSS still stores with HTML codes are shown with the real characters.** 2.4.26 corrected such a name
255
+ only when the dSS reported it without the codes today. A dSS keeps a name the way old firmware stored it until it
256
+ is set again, so `getCircuits` can still answer `Büro &amp; Duschbad` - on a real installation three circuit
257
+ folders kept that name after the update, and no correction was logged. Every name from the dSS is now decoded
258
+ before its object is created, so the one-time correction of 2.4.26 takes effect at the first start and the log
259
+ says so. A name you changed yourself is not touched, and no ID changes
260
+ * **`INVALID scenecall` is gone.** A scene call that finds no scene state is logged with zone, group and scene. Two
261
+ kinds are expected and go to debug: the climate control calls the scenes of group 48 in every room at its switch
262
+ times, also in rooms without heating, and a command such as Stop on group level only exists as a device scene
263
+ state. Any other one is named once per run at info, then at debug
264
+ * **Energy meter values are rounded to whole watt hours.** `EnergyMeterValue` carried values such as
265
+ `4009.7331175000004` kWh, now it is `4009.733`. The total is rounded, not the step, so nothing adds up
266
+ * **Unchanged meter readings are not written again.** `PowerConsumption` and `EnergyMeterValue` are polled every 100 s
267
+ and were written every time, although two thirds of the power readings and a third of the meter readings repeated
268
+ the value before. They are now written when the value changes, so the timestamp of these states only moves with a
269
+ change; `info.apiActivity` shows that the meters are still read
270
+ * **A value another adapter or a script writes into a polled state is corrected again.** The adapter remembers what
271
+ is in each state so that a poll can skip an unchanged value but still correct a foreign one. The acknowledged echo
272
+ of a foreign write was stored under the ID with the namespace, the polls compared the ID without it, so such a
273
+ value was never noticed. This affected the reconciliation of the device outputs as well
274
+ * **The debug log is about half as long.** A command (`ack = false`) is still logged at debug; the confirmations, mostly
275
+ the adapter's own writes and `info.apiActivity` every 30 s, are logged at silly
276
+ * **An unknown addon state is named once at info.** States of dSS addons that have no object, such as
277
+ `operationmode.3.NotUsed` of the climate control, were only visible in a debug log. They are now reported once per
278
+ run like any other unknown state. The internal helper states `<dsuid>_open-tilded` and `queue-active` stay at debug
279
+
280
+ ### 2.4.26 (2026-09-26)
281
+
282
+ * **Rooms no longer report heating as active while the dSS does not know.** As long as it has no information,
283
+ the dSS answers the room state `heating` with "unknown". The adapter counted this word as true, so every room
284
+ showed heating active, and every start logged one warning per room. Such a state now stays empty (null) until the
285
+ dSS reports active or inactive, and the warnings are gone. This applies to every state the adapter shows as
286
+ true/false. States that keep the wording of the dSS, such as the device states (`states.0`, ...) and the user
287
+ states, show the word "unknown" as before. A null that a script writes into a state is no longer sent to the dSS
288
+ as "inactive"
289
+ * **States the adapter cannot write are marked read-only.** This covers the colour and brightness channels of
290
+ multi-channel vDC lights (Hue), the volume and power state of Sonos players, the indoor channels of GR-KL300
291
+ blinds, the output value of a joker, all device sensors, the outdoor sensors and `buttonClickType`. These states
292
+ carried no write flag at all, so the admin offered to edit them although a change had no effect. The states that
293
+ can be written (scenes, lights, blinds, single-channel outputs, room sensors, user states, the set points under
294
+ `temperatureControl.setpoints`) are unchanged. A device sensor such as "Room Temperature Set Point" only reports
295
+ the value of the device and is read-only as well; a vis widget or script that still writes it now causes the
296
+ js-controller warning `Read-only state ... has been written without ack-flag`. The room temperature is set
297
+ through `temperatureControl.setpoints.*` or `OperationMode`. The flag is corrected automatically on the first
298
+ start
299
+ * **Names stored with HTML codes are corrected once.** Older dSS firmware kept the names of circuits, rooms and
300
+ devices with HTML codes, for example `Schlafen &amp; Bad` instead of `Schlafen & Bad`, and the objects created
301
+ back then kept that name, because the adapter leaves object names alone so that your own renames survive. Such
302
+ a name is now replaced once by the name the dSS reports today, and the log says so. A name you changed yourself
303
+ is not touched
304
+ * **The startup report no longer asks for an issue about the second input of a 2-way button.** When the push
305
+ buttons of a shade terminal block such as the GR-KL300 are wired as a 2-way switch, the dSS couples the second
306
+ input to the first and lists the pair as one device, while it keeps a state for the second input. The adapter
307
+ found no device for that state and asked for a GitHub issue. It now names such a state on debug together with
308
+ the device it belongs to, and the info line only lists states that really cannot be assigned
309
+ * **A restart the adapter asks for is no longer logged as a warning.** Instead of
310
+ `Terminated (-100): Without reason`, ioBroker now logs `Terminated (START_IMMEDIATELY_AFTER_STOP): restarting
311
+ because ...` with the reason at info level. The instance shuts down cleanly before it restarts. In compact
312
+ mode that keeps the old instance from running on next to the new one, and the restart follows after 1 s
313
+ instead of 30 s. In compact mode the adapter writes the reason in an info line of its own, and the line of
314
+ ioBroker says `Without reason`: js-controller would log a reason handed over there as a warning of the host
315
+ * **An unreachable dSS no longer fills the log.** While the dSS could not be reached at startup, the adapter ended
316
+ its process every 5 minutes and started again: one night on a real installation produced 102 restarts, 204 error
317
+ lines and 101 warnings. It now keeps running and asks again every 5 minutes. There is one error that says what to
318
+ check, and one info line with the duration when the dSS answers again. A different error in between, for example
319
+ a refused login, is reported once more. A dSS that refuses the App-Token is reported as a refused login, not as
320
+ unreachable
321
+ * **A state of the dSS the adapter does not know yet is named once.** `Unhandled State Change` for a state without
322
+ an object was logged at info level every time it changed: a room crossing its passive cooling threshold wrote
323
+ the same line four times in five hours. It is now logged once per run at info level, and every further change
324
+ of it at debug level. The line says that a state added in the dSS after the adapter started gets its object at
325
+ the next start, and asks to report the name only if it is still reported after a restart
326
+ * **Rooms under passive cooling have a read-only state for it.** The climate control of the dSS keeps a state for
327
+ each room it cools passively: active while the room temperature is above the passive cooling threshold set for
328
+ that room, inactive once it drops below. The dSS keeps such states of its apps apart from the other states, so
329
+ the adapter never read it and only logged each change as `Unhandled State Change`. It is now read at startup
330
+ and becomes `apartment.<floor>.<room>.states.passiveCooling` (true/false), with a value right after the start
331
+ and every change the dSS reports. A dSS that does not offer these states starts as before. When reading them
332
+ fails at a start, the states of the last start stay, with their last value, until the dSS reports a change
333
+
334
+ ### 2.4.25 (2026-09-17)
335
+
336
+ * **An outdoor sensor no longer disappears when the dSS reports no value for it.** The dSS leaves a value out of
337
+ its answer once it has gone stale - an outdoor brightness sensor stops sending in the dark - and the state was
338
+ then not created at all. A sensor that ioBroker already knows keeps its object and its last value now
339
+ * **The apartment state `heating_water_system` keeps the wording of the dSS.** A real installation answers
340
+ "hot water", and as a boolean every word but "inactive" collapsed to true, so the operating mode was lost. An
341
+ apartment state without an active/inactive pair is no longer written to the dSS either
342
+
343
+ ### 2.4.24 (2026-09-17)
344
+
345
+ * **Commands that follow each other quickly keep their order.** A waiting command was merged into an identical
346
+ older one even when another command had been queued in between: on, off, on ended off, and a brightness value
347
+ set while the light was being switched off could be lost. The merged command now moves to the end of the
348
+ queue, so the last wish wins while identical commands still go to the dSS only once
349
+ * **A value that keeps changing no longer postpones everything.** Every new value restarted the 500 ms wait, so
350
+ nothing was sent at all while a slider was moving - and a command for another device of the same circuit
351
+ waited just as long. The wait is bounded now: the queue keeps sending while the changes continue, with the
352
+ same minimum distance between two requests
353
+ * **The notification channel comes back after a failed login.** When the session login failed while the Smart
354
+ Home websocket was reconnecting, no further attempt followed until the adapter was restarted. The login is
355
+ part of the retry now, and a stop during the login no longer opens a connection afterwards
356
+
357
+ ### 2.4.23 (2026-09-17)
358
+
359
+ * **The object warning limit can be seen and changed on the settings tab.** Instances that were created before
360
+ this adapter suggested 10000 often still have 5000, and ioBroker then warns at every start. The card shows
361
+ the limit that is really set, the adapter default and the state, explains what the limit does and what it
362
+ does not do, and saves a new value with the normal Save button - without restarting the instance. The new
363
+ limit applies from the next start
364
+ * **Closing the dialog with unsaved changes asks only once.** Before, the dialog and Admin both asked
365
+ "discard?" one after the other
366
+
367
+ ### 2.4.22 (2026-09-01)
368
+
369
+ * **The adapter listens while it is still building.** For 149.7 seconds after the start
370
+ nothing reached ioBroker - every button press, every window contact and every sensor
371
+ reading between "starting" and the active subscription was gone for good. Almost none of
372
+ that was waiting for the dSS: the classic structure read was answered 2.6 seconds after
373
+ the start, the remaining 147 s are parsing it and creating 5231 objects. The subscription
374
+ moves to the front now, and the level values that arrive while the objects are built are
375
+ applied afterwards - on top of the initial snapshot and never before it, because the
376
+ snapshot is the older picture. Button presses and scene calls are deliberately NOT caught
377
+ up: acting on a press two minutes late is worse than losing it, and the scenes are
378
+ re-read at the end of the start anyway. The five zone reads of the build-up also stopped
379
+ sitting on a 10 s grid, which alone was 50.6 s of waiting on an empty queue
380
+ * **A poll no longer re-asserts a value that has not moved.** 7661 of 11015 state writes in
381
+ a three hour log carried the value that was already there - 69.6 %, and 197 of the 316
382
+ state ids held exactly ONE value for the whole run. The five minute reconcile rewrote
383
+ ~151 output values every time and changed one of them in three hours; the zone
384
+ temperature states were rewritten after every sync, 875 of 885 identical. Only the
385
+ polling and reconciling paths compare now: an event keeps being published even when the
386
+ number repeats, because "the dSS reported this now" is a message of its own, and so does
387
+ the confirmation of a command, which has to reach its acknowledgement. What is in a state
388
+ is tracked from both directions, so a value another adapter wrote is still corrected
389
+ * **A Stop lets go again.** `scenes.Stop` went true on the first press and stayed true: the
390
+ dSS sends the callScene and never the undoScene that would release it - six of them in
391
+ three hours, not one counterpart - so a rule on it fired once and never again. Stop,
392
+ Increment, Decrement, Area Stepping Continue and Impulse are released after half a
393
+ second, and a repeat re-arms that instead of adding a second edge, because a wall switch
394
+ repeats its Stop (measured three times within 481 ms while the blind never moved). A
395
+ blind driven to Maximum keeps its latch - it really IS at Maximum - and the scenes of the
396
+ temperature control group, where the same numbers mean lasting modes, are untouched.
397
+ `scenes.sceneId` still answers which scene was called last
398
+ * **A pressed button lets go again.** `<device>.<n>.button` had exactly the problem the
399
+ momentary scenes had, on the state right next to them: the dSS reports a press and never
400
+ takes it back, so the state stayed true from the first press to the end of the run and a
401
+ rule on it fired once. It is released after half a second now, from both paths that set
402
+ it - the button event and the scene call a wall switch produces. `buttonClickType` and
403
+ `buttonHoldCount` keep their values; they describe the press, not the moment
404
+ * **Five apartment states finally carry a value.** `daylight`, `daynight`,
405
+ `daynight_indoors`, `twilight` and `holiday` were created empty and stayed empty, because
406
+ the adapter read only the word a state describes itself with. The dSS sends these five
407
+ with a raw value and no word at all - measured: `{"name":"daylight","value":true,
408
+ "script_id":"solar_computer"}` - so there was nothing to read. Both forms are taken now,
409
+ and the conversion handles a boolean as well as "off"
410
+ * **A vDC read counts as a read, and may be repeated.** The status tab showed the chip
411
+ "classic" next to 0 output reads while 136 of them were running for four Sonos players:
412
+ the named channel read is called `getOutputChannelValue2` and matched no counter. The
413
+ same read was also missing from the retryable requests, although for a Sonos player it is
414
+ the ONLY path to volume and power state
415
+ * **Six devices stop being called "(undefined)".** `outputMode 64` is a heating valve
416
+ terminal and was not in the map. An unknown mode no longer reaches the object name at
417
+ all; it is logged instead. Existing installations keep the name they have
418
+ * **Four apartment states say what the dSS really sends.** They declared "true"/"false"
419
+ while the dSS answers "active"/"inactive". The values were right anyway through the
420
+ fallback, but a write would have sent the wrong word - and the only line that said so sat
421
+ on debug and fired five times unseen. It warns once per state now
422
+ * **The startup report stops asking for issues about our own decisions.** Of the 45 states
423
+ it listed as unassignable, 42 belonged to zones and groups this adapter had itself
424
+ decided not to build objects for. They are subtracted now, so what is left are the names
425
+ that really belong to nobody
426
+ * **The cluster locks get the words the dSS answers with.** `user_lock` and
427
+ `operation_lock` were created without a value mapping, so their write handler could only
428
+ ever warn - the path behind it had never run
429
+ * **The hourly probe of a learned channel stops costing four answers.** A channel the
430
+ status never answers is probed once an hour so the learning cannot latch forever, and
431
+ that probe spent the full follow-up budget: twelve of the eighty-four status requests of
432
+ a three hour run, healing nothing. It rides along with one status request now
433
+ * **Three numbers meant something else than they looked like.** `info.apiActivity`
434
+ announced a ten minute window and measured between nine and ten, 4.9 % low and always in
435
+ the same direction. The shutdown printed a long-poll deadline where it read like a
436
+ duration, suggesting 15 s for an unload that took 116 ms. And "Plan next queue entry"
437
+ named the entry that had just finished while the priority in the same line belonged to
438
+ the one being planned
439
+
440
+ * **A blind no longer gets the guessed scene value written first.** The preset was the stand-in
441
+ for a position nobody could know while the blind travelled - with the Smart Home API the real
442
+ one arrives about two seconds later and follows the movement, so the guess only added a jump.
443
+ It also carries the value of the GROUP scene, which is not always where the individual device
444
+ travels: measured on a real installation, a blind was written 50 while it went to 60, and that
445
+ wrong value stood for 21 seconds. Without the Smart Home API the preset stays exactly as it was
446
+ * **A user state is only written to the dSS when its value really changes.** Scripts that
447
+ re-assert their states every few minutes had every single write forwarded, even when the dSS
448
+ already held that value - measured: 31 pointless requests in 40 minutes, by then the largest
449
+ remaining load on the classic interface. The value the dSS reports is tracked from both
450
+ directions, so a state someone changed in the dSS is never mistaken for unchanged
451
+ * **A travelling output no longer reports its target before it arrives.** The interpolation used
452
+ to clamp at the target, so once the announced end had passed while the dSS still said "moving",
453
+ the state claimed the blind was there - seen on a real travel 2.1 seconds early. Nothing is
454
+ written in that moment now; the real value follows within about two seconds, because the channel
455
+ keeps its fast schedule for a short grace period after the announced end (a device stuck on
456
+ "moving" still runs into the normal follow-up handling)
457
+
458
+ * **A joker with an output follows its scenes.** A switched socket has an output value, but no
459
+ read path of its own: it only ever arrived with the next reconciliation - measured on a real
460
+ installation, the value of a socket switched on at 10:20:04 appeared at 10:21:02, 57 seconds
461
+ later. It is now read at startup and right after a scene call, through the same bundled status
462
+ request every other device type uses, so a whole room still costs ONE read. Without the Smart
463
+ Home API nothing changes: a joker output has no other way to be read, and the reconciliation
464
+ stays responsible
465
+
466
+ ### 2.4.21 (2026-08-31)
467
+
468
+ * **vDC devices (Hue, Sonos and friends) read their outputs at all for the first time.** They have
469
+ no typed device path of their own, so the generic branch left them without any read: one channel
470
+ got an offset read the dSS cannot answer for them ("Could not find item. deviceOutputIndex:255"),
471
+ several channels got nothing but a debug line. Their values existed only where the Smart Home API
472
+ status happened to carry them. Now the named read `device/getOutputChannelValue2` serves them -
473
+ verified live against a dSS20 1.19.13: the audio volume and power state of Sonos players get
474
+ values for the first time ever, and the colour values of vDC lights work without the Smart Home
475
+ API too. One answer carries every channel of a device and concurrent requests coalesce into one.
476
+ A scene call refreshes the values right away as well: through the bundled status request, or -
477
+ without the Smart Home API - through one named read for the device the scene addressed directly.
478
+ Native terminals keep their offset read (filtered by the structure flag), and a dSS that rejects
479
+ the named call is remembered per device
480
+ * **Metering sensors the dSS marks invalid are read once at startup** (low priority, one bus read
481
+ per sensor): active power, output current and apparent power of measuring terminals. A device
482
+ with constant consumption - a printer in standby - may not send a sensor event for months, so
483
+ these states stayed empty since their objects were created. Energy meter and high range current
484
+ natives have unverified resolutions and deliberately stay with the events
485
+ * **The Smart Home API key is optional now.** The new API also accepts the login of the classic
486
+ interface as a cookie - measured against a dSS20 1.19.13 for every endpoint this adapter reads
487
+ AND for the notification websocket. Without a key the adapter simply uses the login it has
488
+ anyway, so the Smart Home path needs no second credential. And a key the dSS rejects (revoked,
489
+ or replaced by a newer one of the same name) no longer takes the path down: the adapter says so
490
+ once, switches to the login and keeps going. A configured key stays the primary path - it is
491
+ permanent and needs no renewal
492
+ * **A blind now follows its travel live instead of jumping at the end.** The status leaves the
493
+ value out while an output moves - but it carries the whole journey: where the travel started,
494
+ where it goes, and the window it takes. Every movement brings its own window from the dSS, so
495
+ a slow awning and a fast roller shutter are equally right and nothing is assumed. The position
496
+ is computed from it and written during the travel, the channel stays open for the real final
497
+ value, the next read is due right after the travel ends instead of on the fixed 15 s grid, and
498
+ a running travel no longer burns the follow-up budget (measured live on a dSS20 1.19.13: a full
499
+ travel from 100 to 0 in 24.8 s)
500
+ * **The CIE x/y colour coordinates arrive correctly scaled.** The channel scale delivers them as
501
+ 0..1 while the states hold 0..10000 - since 2.4.18 rounding collapsed every coordinate to 0
502
+ or 1 on the Smart Home API path; the new named read applies the same corrected factor
503
+
504
+ ### 2.4.20 (2026-08-31)
505
+
506
+ * **The power level alias scales correctly.** The live smoke test of 2.4.19 refuted the assumed
507
+ 0..100 scale of the `level` field: a switched socket powering a device reported `level: 1` and the
508
+ `powerLevel` state showed "1 %". The field is 0..1 (matching the structure, which normalizes the
509
+ switch threshold to 0..1 as well) and is now scaled and clamped to the 0..100 state
510
+
511
+ ### 2.4.19 (2026-08-31)
512
+
513
+ * **`info.outputApi` no longer ping-pongs between the two APIs.** On hybrid installations single
514
+ channels the status structurally never delivers (measured live: the outputs of audio devices are
515
+ missing from the status entirely) made the state flip to "classic" about a minute after every
516
+ reconciliation and back with the next one - roughly every five minutes, around the clock. Classic
517
+ reads the sync hands over for such single channels no longer report; "classic" now shows while
518
+ the status request itself fails, while the Smart Home path pauses in its backoff, with the option
519
+ off - or once at adapter start when a generic single-channel device (neither light, shade nor
520
+ joker hardware) delivers its initial value via the deliberately classic read
521
+ * **Channels the status never answers are learned** after two exhausted follow-up budgets and go to
522
+ the classic read immediately - their values arrive ~60 s earlier and the pointless follow-up
523
+ status requests (four per trigger, ~59 KB each) stop. A later status answer that carries such a
524
+ channel again heals the learning automatically
525
+ * **Two id mismatches of the status are resolved by aliases**, so the affected channels are served
526
+ by the Smart Home API after all: a switched socket (SW-KL200) reports its declared `powerLevel`
527
+ as the `level` field of a `powerState` output, and blinds (GR-KL300) report the single class-64
528
+ shade bank only under the `...Outside` ids although they declare the `...Indoor` channels as
529
+ well - the classic read would have delivered the identical value to both. The `powerLevel` state
530
+ of such sockets gets a value for the first time ever
531
+ * The helper states of the dSS window-states addon (`<dsuid>_open-tilded`) log at debug instead of
532
+ info level - the window state itself arrives via the binary input and the device state anyway
533
+ * **The status tab shows live what each interface actually did** in the last 10 minutes
534
+ (`info.apiActivity`, published every 30 s): received events and sent commands of the classic API,
535
+ meter and status reads of the Smart Home API and its notifications - the proof that a path really
536
+ works, not just that it is configured
537
+
538
+ ### 2.4.18 (2026-08-31)
539
+
540
+ * **Device output values can be read through the Smart Home API.** With the option enabled, the
541
+ initial reads at startup and the re-reads after every scene call are served by ONE apartment
542
+ status request (~59 KB, ~100 ms for every device at once) instead of one throttled classic read
543
+ per output channel - the part of the startup that could take minutes on large installations.
544
+ The status delivers each output already in the scale of the ioBroker states, verified offline
545
+ against a real object export: every comparable value matches, and 132 channel states the classic
546
+ path never managed to fill (hue, colortemp, x, y of the lights) finally get their values
547
+ * The rules learned from live measurements are built in: an output that is currently **moving
548
+ carries no value** in the status and keeps its last state (asked again after 15 s, at most four
549
+ times, then the classic read has the last word); an answer that was already on its way never
550
+ satisfies a trigger that arrived after it left; boolean channels stay on the classic read; a
551
+ failed status request falls back to the classic reads at once and pauses the Smart Home path for
552
+ five minutes. With the option off, the values behave exactly as before - the only difference is
553
+ that requests which never worked are no longer sent (a light's colortemp read always went out
554
+ broken and only ever produced a warning)
555
+ * **The new-API client cannot hang any more.** A connection dying in the middle of a response body
556
+ used to leave the request pending forever - no error, no retry. The classic client always had
557
+ this handler, the new one was missing it. A wrong password during key creation now surfaces the
558
+ actual answer of the dSS instead of a generic sentence
559
+ * **The API key dialog uses the app token from the form.** Creating the app token and the API key
560
+ in one visit used to fail with "Please create or enter the App-Token first", because the instance
561
+ only knew the SAVED token. A stored API key that does not look like one (typically: js-controller
562
+ could not decrypt it after a backup restore) is called out at startup instead of an anonymous
563
+ HTTP 401, and a dSS without /api/v1 (HTTP 404) backs off to the maximum right away and says so
564
+ once instead of warning every hour
565
+ * Groundwork hardening of the notification websocket (still unused): dead connections are detected
566
+ by pinging after 30 s of silence and reconnecting after 90 s, fragmented messages are capped in
567
+ total size, and the debounce defaults follow the measured reality (5 s coalescing, 15 s maximum)
568
+ * **The notification websocket is now used - as a deliberately throttled safety net.** Every meter
569
+ tick fires a payload-free notification (measured: 17 in 75 seconds), while buttons and scenes are
570
+ already reported precisely by the classic events. A notification therefore triggers a
571
+ reconciliation of all output values at most every five minutes: it catches what happens past
572
+ ioBroker - a third-party app writing an output directly - without adding steady load. The channel
573
+ reconnects on its own, and a dSS without it changes nothing
574
+ * **Each status answer also refreshes the room temperature control of every zone** - setpoint and
575
+ control value, verified degree- and percent-identical against a real installation; the operation
576
+ modes stay with the classic path. And the scene names given in digitalSTROM are loaded once from
577
+ the new API to fill the gaps the classic naming leaves
578
+ * **The settings explain the hybrid approach and show it working.** The connection tab walks
579
+ through three numbered steps - server address (entered once, it serves both interfaces), the app
580
+ token as the base access in its natural order (credentials first, the created token lands below),
581
+ and the Smart Home API key as the accelerator - side by side on a PC screen. A new status tab
582
+ shows the division of labour live: which interface currently delivers events, meter values and
583
+ output values, backed by the new state `info.outputApi`, the counterpart of `info.meteringApi`
584
+
585
+ ### 2.4.15 (2026-08-30)
586
+
587
+ * **The dialog scrolls by itself now.** It used `minHeight: 100%` and relied on the surrounding frame
588
+ to provide the scrolling. Where that frame does not scroll, everything below the first screen height
589
+ was unreachable and the lowest button stayed under the save bar - which is why more bottom spacing in
590
+ 2.4.12 and 2.4.14 did not help. With `height: 100vh` and its own `overflow-y` the content is reachable
591
+ in either case; verified against a deliberately non scrolling frame, 71 px clear below the last button
592
+
593
+ ### 2.4.14 (2026-08-30)
594
+
595
+ * **The meter values can optionally be read through the new Smart Home API.** One request for all
596
+ circuits instead of two per circuit - measured on a dSS 1.19.13 with six circuits: 12 requests in
597
+ 734 ms become one in 114 ms, which takes the steady load of this adapter from about 8.7 to about
598
+ 2.1 requests per minute
599
+ * The switch is **off by default** and every failure falls back to the classic API, so nothing changes
600
+ until it is turned on. The API key is created from the EXISTING app token, no password is needed
601
+ again
602
+ * Values and states stay identical. Both APIs were compared against each other beforehand: five of six
603
+ circuits matched to the watt second, the sixth differed by exactly the time between the two reads.
604
+ The unit is watt seconds, so the conversion `value / 3600 / 1000` is unchanged - note that the API
605
+ declares `Wh`, which is demonstrably wrong and would have been off by a factor of 3600
606
+
607
+ ### 2.4.13 (2026-08-30)
608
+
609
+ * **One long-poll instead of nine.** `subscribeEvents()` gave every event name its own
610
+ subscription id, so nine `event/get` long-polls were open at the same time, each of them
611
+ re-established every 40 seconds. The DSS allows many event names on ONE subscription id -
612
+ that is what openHAB and the Home Assistant integrations do - and answers all of them
613
+ through a single `event/get`. All events now share the id from the configuration (42 by
614
+ default), which removes the biggest steady load the adapter put on the DSS. Nothing about
615
+ the events themselves changes
616
+ * Two details follow from that: a re-subscribe after a failed poll registers **every** name of
617
+ the channel again, because the DSS loses the whole subscription id and not just the one name
618
+ whose poll failed; and the polling only starts after the last subscription, so no event can
619
+ be missed while a subscription is still on its way. Unsubscribing at the end is one request
620
+ instead of nine
621
+ * The lowest button of a tab needed more room below the save bar of the admin than 2.4.12 gave
622
+ it. The design preview (`npm run dev:admin`, `preview.html`) now shows a stand-in of that bar
623
+ so the spacing can be checked without the admin
624
+ * New: `scripts/probe-smarthome-api.js` reads a DSS through the new Smart Home API
625
+ (`/api/v1` plus the notification websocket) and writes every answer to a directory. It is the
626
+ groundwork for the decision whether the adapter can be moved to that API
627
+
628
+ ### 2.4.12 (2026-08-30)
629
+
630
+ * **The app token was decrypted twice.** It was named in the `encryptedFields` option of
631
+ `GenericApp` and, at the same time, in `encryptedNative` of io-package.json - and
632
+ `onPrepareLoad` decrypts its own list plus the fields of `encryptedNative`. Decrypting twice
633
+ returns the ciphertext, so the dialog would have shown an unusable value and saving from
634
+ there would have stored a token the adapter cannot use. `encryptedNative` alone is
635
+ authoritative now, and a test makes sure the field is not declared in both places again
636
+ * The lowest button of a tab sat directly underneath the save bar of the admin, which is fixed
637
+ to the bottom edge. The content keeps room below it now
638
+
639
+ ### 2.4.11 (2026-08-30)
640
+
641
+ * **Fixed a configuration dialog that could not connect.** The React dialog introduced in
642
+ 2.4.10 only reported `Socket connection could not be initialized: Error: Socket library could
643
+ not be loaded!` and stayed empty. `@iobroker/socket-client` does not bring socket.io along,
644
+ it expects the page to have loaded it as a global - admin serves it at
645
+ `/lib/js/socket.io.js`. The page loads it now and offers `registerSocketOnLoad`, so the
646
+ client is told when the library is there instead of polling for it. A test checks both,
647
+ because the dialog is unusable without them and nothing else notices
648
+
649
+ ### 2.4.10 (2026-08-30)
650
+
651
+ * **The configuration dialog is a React application of its own now.** jsonConfig describes a
652
+ form, it does not design one - headers were rendered as full width bars in the primary colour
653
+ of the admin theme, and the colours set for them only ever reached the text. The dialog is
654
+ written directly instead: a light surface independent of the admin theme, raised cards per
655
+ topic, a header with the adapter icon and tabs with icons. The app token can be revealed and
656
+ says whether it is stored. Sources live in `src-admin`, the build lands in `admin` and is
657
+ committed, because the adapter is installed straight from this repository. All eleven
658
+ languages were taken over from the former `admin/jsonConfig.json`, nothing was translated
659
+ anew. `npm run build:admin` builds it, `npm run dev:admin` serves `preview.html` for looking
660
+ at the layout, and the workflow rebuilds the bundle and fails if it differs from the
661
+ committed one
662
+ * This also removes a whole class of error: the credentials for creating an app token used to
663
+ travel through a JavaScript template literal in `jsonData`, where a quote in a password could
664
+ break the message. They are now passed as a plain object. The 43 tests that guarded the
665
+ jsonConfig and that escaping were dropped, 6 new ones check the built interface, the
666
+ agreement of the eleven translation files and that every text the dialog asks for exists
667
+ * **Binary inputs name their values.** The state kept the bare number of the DSS, so a window
668
+ handle read 1, 2 or 3 without anything saying what that meant. Observed on an EnOcean window
669
+ handle (F6-10-00), each position checked against the readable device state of the same
670
+ handle: closed 1, open 2, tilted 3. Every other binary input keeps two values, 1 inactive and
671
+ 2 active. The type stays `number`, so existing history data remains comparable
672
+ * Dependency updates: `@apollon/iobroker-tools` 0.3.0, `actions/checkout` 7,
673
+ `actions/setup-node` 7, `@types/node` 26, `@types/sinon` 22, `@types/proxyquire` 1.3.31,
674
+ `@alcalzone/release-script-plugin-license` 5.2.2. chai 6, sinon-chai 4, chai-as-promised 8
675
+ and TypeScript 7 were deliberately not taken: the chai family is ESM only, which the type
676
+ check of a CommonJS project rejects, and `@typescript-eslint` pins TypeScript below 6.1
677
+
678
+ ### 2.4.9 (2026-08-30)
679
+
680
+ * **Fixed an invalid admin configuration.** The two dividers of the layout introduced in 2.4.5
681
+ carried a colour of the digitalSTROM palette, but the schema only allows `primary` and
682
+ `secondary` for that property. admin therefore rejected the whole config with
683
+ `digitalstrom has an invalid jsonConfig` and fell back to a generic dialog. The colour now
684
+ lives in `style`/`darkStyle`, where a free colour is allowed. Two new tests check the enum
685
+ constrained properties of the schema, so this class of error cannot come back unnoticed
686
+ * The release workflow of this fork no longer tries to publish to npm - the package name
687
+ belongs to the upstream project. A pushed tag `v<version>` now only creates the GitHub
688
+ release, and its text comes from the message of the annotated tag
689
+
690
+ ### 2.4.8 (2026-08-30)
691
+
692
+ * Removed the App-Token migration note from the admin dialog and from the readme. No public
693
+ release ever shipped the misplaced `encryptedNative` declaration, so a permanent hint about
694
+ a migration nobody has to do would only confuse. The adapter still detects a token it cannot
695
+ read back and says so in the log, now without referring to a version history
696
+
697
+ ### 2.4.7 (2026-08-30)
698
+
699
+ * **The default data polling interval is 100s instead of 60s.** Measured against a productive
700
+ installation with 6 metering circuits: a cycle reads two values per circuit
701
+ (`getConsumption` + `getEnergyMeterValue`) and the timer for the next cycle only starts once
702
+ both are answered, so a cycle takes roughly 20s longer than the configured interval. With 60s
703
+ that resulted in a measured 1.53 requests per minute and circuit - one and a half times what
704
+ the digitalSTROM rules 8/9 allow. 100s gives a cycle of about 120s and therefore exactly 1.0.
705
+ The claim in 2.4.4 that 60s complies with those rules counted only one read per cycle and was
706
+ wrong. The minimum stays at 60s: lower values remain possible, they are now just honestly
707
+ documented as exceeding the guideline instead of being called compliant
708
+
709
+ ### 2.4.6 (2026-08-30)
710
+
711
+ Built from the object export and the debug log of a productive installation.
712
+
713
+ * **Room temperature control.** Every room the DSS really regulates gets a channel
714
+ `temperatureControl` with `ControlMode` (which kind of controller), `ControlState` (who
715
+ owns the set point) and `OperationMode` - a readable, writable mirror of the group 48
716
+ scenes that follows every scene call. Rooms with `ControlMode: 0` deliberately stay
717
+ without those objects, so it is visible at a glance which rooms are regulated at all
718
+ * **Set points per operation mode.** They are read with `zone/getTemperatureControlValues`
719
+ and written with `zone/setTemperatureControlValues`. The field names are taken from the
720
+ answer instead of being hard coded, and the states are only created when the DSS really
721
+ answered - a firmware without that endpoint gets no set point objects rather than dead ones
722
+ * `NominalValue` stays writable but only takes effect when the zone is under external
723
+ control (`ControlState` = external). With the internal controller the DSS overwrites the
724
+ pushed value - use `OperationMode` or the set points instead
725
+ * **Cluster states.** `cluster.<id>.user_lock` and `cluster.<id>.operation_lock` had no
726
+ object at all, although the group folder of the cluster exists. They are created below
727
+ `apartment.groups.<id>.states` now
728
+ * **Group states with a dot in their name.** `status.malfunction` and `status.service` of
729
+ the ventilation groups were dropped by a pattern that only matched a single segment. They
730
+ are created as nested states now, including the channel in between
731
+ * The check for rooms that belong to no floor evaluated `isValid` as a plain truthiness
732
+ check. A real DSS does not send that flag for a zone at all, which silenced the check
733
+ completely. It now only skips a zone that the DSS explicitly marks as invalid or as not
734
+ present (`isPresent: false`, e.g. the dS zone 65534 for unassigned devices)
735
+
736
+ ### 2.4.5 (2026-08-30)
737
+
738
+ * Redesigned the admin configuration. The options are split into the tabs **Connection**,
739
+ **Settings** and **Notes** instead of one long page, with section headers, info boxes and
740
+ switch cards in the digitalSTROM colours (`#00662E` / `#7FC241`, taken from the logo)
741
+ * The new **Notes** tab explains the certificate check
742
+ * No option was renamed and none was dropped - existing instance settings are taken over
743
+ unchanged. A test now asserts that every option of `native` still has a control
744
+
745
+ ### 2.4.4 (2026-08-14)
746
+
747
+ Found by a systematic multi-agent review of the whole adapter. All of these defects already
748
+ existed in 2.4.2 and earlier - they fail silently, which is why they never showed up as an error.
749
+
750
+ * **A scene called for a whole room never reached the device handlers.** `zoneDevices` is only
751
+ keyed by the real device groups (1, 2, 8 ...), never by the broadcast group 0, so the fan-out
752
+ found nothing - and the forwarding loop that runs afterwards is marked as "forwarded", which
753
+ disabled it as well. Effect: after every "room off" the states `brightness`,
754
+ `shadePositionOutside` and `shadeOpeningAngle*` kept their old value until the next group
755
+ scene hit the same device or the adapter restarted, without a single log line. The adapter
756
+ triggers this case itself: its own room scene states send `zone/callScene` without a groupID
757
+ * **The App-Token is now really stored encrypted.** `encryptedNative` and `protectedNative` were
758
+ declared inside `common` instead of at the root of io-package.json, where `ioBroker.AdapterObject`
759
+ expects them. Neither took effect, so the token was kept in plain text in the object database,
760
+ was readable by every other adapter and was contained in every backup in the clear.
761
+ **Migration:** a token that was saved by an older version cannot be decrypted and is read back
762
+ as garbage. Open the adapter configuration once, enter the App-Token again (or create a new one
763
+ with your DSS login) and save. The adapter now detects this case and says exactly that instead
764
+ of only reporting a failed login
765
+ * **Every press of the first button was dropped on some devices.** The state of button 0 was only
766
+ created for `buttonActiveGroup` 1..8, while the click type and hold count states of the same
767
+ button were always created - and the event handler aborts when the plain button state is
768
+ missing. On a keypad whose button is unassigned, on broadcast, or in a group above 8, buttons
769
+ 2..n worked while button 1 only produced `INVALID Button click`
770
+ * Button click type and hold count were written with the raw DSS string into a state declared as
771
+ a number, so js-controller warned on every press and the `states` mapping did not resolve
772
+ * `EXTRANOUS ZONE found <id>` was logged for every regular room at every adapter start: the check
773
+ ran synchronously while the rooms are processed through `setImmediate`, so its bookkeeping was
774
+ still empty
775
+ * **"Request device output values actively" = false suppressed the scene preset values as well.**
776
+ The option is documented to control only the reads; the preset values belong to "Use scene
777
+ preset values". The gate sat in front of the device handler instead of in front of the read
778
+ * The output channel `shadePositionIndoor` was named "Shade Position **Outside** (curtains)".
779
+ Existing objects keep their old name - ioBroker preserves the name on update
780
+
781
+ ### 2.4.3 (2026-08-12)
782
+
783
+ **Runtime fixes**
784
+ * Event recovery could hang forever: a successful `event/subscribe` reset the error counter, so a DSS that accepted the subscription but answered every `event/get` with HTTP 500 never reached the error limit. The adapter stayed green and re-subscribed every two seconds without ever processing an event again. The counter is now only cleared by a really successful `event/get`, the backoff grows and the defined `eventError` / restart path is reached reliably
785
+ * The stop is a real barrier now: asynchronous startup callbacks that finish during or after the unload no longer create timers, requests, state subscriptions or `connected = true`, `DSS.requestAsync()`/`httpRequest()` reject every request after `stop()`, and a still running App-Token dialog is tracked and closed by the unload (no late `sendTo` and no late log lines from that flow)
786
+ * **Request Device Output values actively = false** disabled the whole blind control: detection of position/angle, the write handlers and the initial read were in one block, so with the option switched off no write command reached the DSS at all. Writing is now independent of the option, which only controls whether output values are *read* (initially and after scene events, for blinds and lights alike)
787
+ * Scene 22 and scene 25 were both called "Preset 24" and therefore shared one state id. The remaining handler controlled scene 25, scene 22 was not reachable. Scene 22 is called "Preset 14" again (as the code comment already said) and a test now checks all generated scene state ids for uniqueness
788
+ * Queue coalescing is re-entrant: the queue entry is replaced *before* the superseded callbacks run. A value that is enqueued synchronously from a superseded callback (typical for a moving slider) is no longer overwritten by the older call. Guaranteed: the newest value is sent exactly once, a replaced value is never sent, every callback finishes exactly once, no callback is lost
789
+ * A superseded write is no longer reported as a warning. The message `Error while set State for apartment-user: SupersededError: ... was superseded by a newer value` was normal last-write-wins coalescing, not a DSS error. Expected queue cancellations are now classified centrally (`DSSQueue.isExpectedQueueError`) and only logged at debug level for all consumers (apartment, apartment-user, circuit, device output, zone, group). Real network, DSS and response errors still produce a warning
790
+ * Events could get lost during startup: the handlers were only registered after *all* subscriptions were done, while every single subscription starts polling as soon as it succeeded. The handlers are now registered before the first poll can emit anything (and never twice). In addition the artificial two second wait before subscribing was removed, and once the subscription is active the last called scenes are checked once with the lowest priority so scene calls during a long startup are applied afterwards
791
+
792
+ **Further fixes**
793
+ * The boolean output channels `airLouverAuto` (ventilation swing mode) and `airFlowAuto` (ventilation auto intensity) accepted only numbers and rejected `true`/`false` - they are switchable again and are sent to the DSS as 0/1. Invalid types are still rejected in a controlled way
794
+ * The apartment ventilation status (sensor 60) was created as a boolean, which turned every status code other than 0 into `true`. It is a numeric state again and keeps all DSS status codes (0 = OK, 2 = Malfunction, 4 = Service, 6 = Malfunction+Service)
795
+ * Heating and ventilation groups activated the generic scene state (e.g. `Preset0`) on startup while every event toggled the special one (e.g. `HeatingOff`). The initial state is now resolved via the state map, exactly like the event handling does
796
+ * Apartment specific cluster names no longer leak between adapter instances: every structure gets its own copy of the group type map and the module constants are never modified at runtime
797
+ * Host normalization: an explicitly configured default port was replaced by the DSS default port 8080 when the host ended with a slash (`https://dss.local:443/` became `https://dss.local:8080`, the same for `http://...:80/` and IPv6). Fixed for host names, IPv4, IPv6, with and without trailing slash
798
+ * A request timeout produced by the adapter itself now carries a structured marker (`code: 'ETIMEDOUT'`), so the retry classifier recognizes it and a safe read is repeated once. Write requests are still never repeated
799
+ * `apartment/getReachableGroups` (a pure startup read) may be repeated once after a connection error
800
+
801
+ **Configuration and maintenance**
802
+ * The minimum data polling interval is 60s now instead of 10s. digitalSTROM rules 8/9 allow at most one cyclic read per minute and circuit, and one cycle already issues several measurement reads per circuit. Configured values between 1 and 59 are raised to 60s, 0 still disables polling completely. **If you configured a value below 60s, the effective interval changes with this update**
803
+ * The App-Token is no longer displayed as plain text in the admin dialog (it was already stored encrypted and protected)
804
+ * CodeQL updated from the unsupported v2 to v4
805
+ * Node.js 22 is the minimum required version (Node 20 is end of life), CI and release run on Node 22 and 24
806
+ * The Dependabot auto-merge workflow was hardened: it no longer checks out pull request code, runs only for pull requests really opened by Dependabot, uses the automatically provided `GITHUB_TOKEN` with minimal permissions instead of a personal access token, and pins the official `dependabot/fetch-metadata` action to a full commit SHA. Merging now happens through GitHub auto-merge, so required checks have to pass first. The policy became stricter: production dependencies only for patch updates, development dependencies for patch and minor updates
807
+ * The whole project is free of type errors now: `npm run typecheck` (`tsc --noEmit` with `strict` and `checkJs`) runs in CI and must stay green. All types are declared with JSDoc - no suppressions, no weakened compiler options
808
+ * DSS states that belong to no device, circuit, room, group or the apartment are reported once with their exact name instead of silently having no object at all
809
+ * Dev dependency updates: 0 known vulnerabilities at all. The findings in mocha and @iobroker/testing are fixed through npm `overrides` (serialize-javascript, diff, esbuild) instead of downgrading the test tooling
810
+
811
+ ### 2.4.2 (2026-08-02)
812
+ * Do not use HTTP keep-alive anymore. The DSS closes idle connections, which caused sporadic "socket hang up" errors on the next request (2.3.0 did not use keep-alive either)
813
+ * Add the missing role to the binary input states (no more "property common.role missing" warnings)
814
+ * Map boolean states via the value mapping reported by the DSS and understand the usual off words (off/inactive/no/0) instead of turning every non-empty string into true
815
+ * Convert values delivered by the DSS to the type declared for the object. The DSS reports numbers as strings, which produced "has to be type number but received type string" messages for sensor values, scene ids and states
816
+ * Retry a **read** request once when the connection was closed without an answer ("socket hang up"). Actions with side effects (`callScene`, `undoScene`, `event/raise`, `state/set`, `pushSensorValue`, output writes) are never repeated automatically - after a connection error the DSS may already have executed them, so a repeat could trigger the scene or an external automation a second time
817
+ * Do not write state values before the corresponding objects exist (no more "has no existing object" warnings during startup)
818
+ * Log unsupported output channels (e.g. the media channels of dS audio devices) at debug/info level instead of flooding the log with warnings
819
+ * Use a separate connection pool for the event long-polls. With 9 parallel long-polls the shared pool (4 sockets) could block every normal command like a scene call indefinitely
820
+ * Fix the request queue merging two writes to the same output: a newer value could be acknowledged although only the older value was sent to the DSS. Now the newest pending value wins, an already running write is no longer overtaken, and a replaced write is reported as superseded instead of successful
821
+ * Isolate queue callbacks: a throwing callback no longer stalls the request queue of that circuit
822
+ * Rework the event retry handling: polling and re-subscribe errors now share one bounded exponential backoff with a single timer per event and reliably end in the defined error path
823
+ * Report failed event subscriptions during startup instead of continuing with a green connection indicator without any events
824
+ * Normalize DSS events defensively - an event without source/properties, an unusable entry or a throwing handler no longer ends the polling loop
825
+ * Remove the `process.exit()` fallback so the adapter can never terminate the shared host process in compact mode
826
+ * Make stopping fully idempotent: every caller is answered exactly once, the DSS client and its agents are closed even if unsubscribing hangs, and running requests are aborted
827
+ * Close the temporary DSS client of the App-Token creation in every case
828
+ * Accept and validate all common host formats (IP, DNS name, URL, IPv6 with and without port) and reject credentials, paths or query strings in the host field
829
+ * Keep `clickType: 0` ("Single Tip") instead of turning it into -1
830
+ * Resolve the initial zone scene via the zone scene names as well, so room scenes are marked correctly and unknown scenes no longer produce an "undefined" state path
831
+ * Validate the polling interval independently of the admin UI - invalid values can no longer create an aggressive timer, and 0 now really disables polling
832
+ * Fix the legacy call signature of `queueSetOutputValue()` which could send the priority string as output value
833
+ * Give the meter states a `type` and interpret written booleans correctly (the strings "false"/"0" are no longer treated as true)
834
+ * Migrate the admin configuration to JsonConfig (replaces the deprecated Materialize UI, works in current and future admin versions)
835
+ * Automatically re-initialize when the DSS reports a changed apartment model (`model_ready` event) - structure changes and DSS restarts are now picked up without a manual adapter restart
836
+ * Migrate to ESLint 9 with @iobroker/eslint-config and Prettier, remove the gulp based build tooling
837
+ * Add real unit tests for the DSS client, the request queue and structure helpers
838
+ * Replace the unmaintained ds-wrapper library with an own implementation based on native Node.js https. This removes the deprecated `request` dependency including known vulnerabilities (CVE-2025-7783 in form-data, CVE-2023-26136 in tough-cookie)
839
+ * Add timeouts to all DSS requests. Hanging requests could previously block the command queue of a circuit, stop the meter data polling and freeze event polling forever
840
+ * Treat DSS error responses (`ok: false`) as errors. Previously a lost event subscription (e.g. after a DSS restart) resulted in a tight polling loop without events ever arriving
841
+ * Fix the event polling error counter (`x = x++` bug) so re-subscription and adapter restart actually happen after repeated errors
842
+ * Fix error propagation of failed event subscriptions on startup (failures were silently swallowed and the adapter pretended to be connected)
843
+ * Do not delete objects of devices that are unknown/unreachable during startup anymore. This previously destroyed history/InfluxDB configurations. Deletion is now an opt-in via the new "Delete unknown objects on startup" setting
844
+ * Store the App-Token encrypted (`encryptedNative`/`protectedNative`) and do not write it to the log anymore
845
+ * Change the admin password field to a real password input
846
+ * Remove the `uncaughtException` handler. Crashes now properly terminate the adapter so js-controller can restart it (previously the adapter stayed alive as a zombie doing nothing)
847
+ * Set `info.connection` to `false` when all meter requests fail, so a dead DSS connection becomes visible
848
+ * Add a startup watchdog: if initialization does not finish within 10 minutes the adapter restarts
849
+ * Route `getReachableScenes` startup requests through the request queue instead of firing them all at once
850
+ * Add optional TLS certificate validation ("Validate TLS certificate of the DSS" setting, off by default because the DSS uses a self-signed certificate)
851
+ * Fix operator precedence bugs in the UMV min/max handling and the shade angle update
852
+ * Fix `states` definition of buttonClickType objects so the click type labels are shown in admin
853
+ * Fix last-scene tracking for group undoScene calls
854
+ * Skip `undefined` initial values to avoid js-controller warnings
855
+ * Clear pending queue entries and timers properly on adapter stop
856
+ * Normalize all boolean settings centrally. A value stored as the string `"false"` (e.g. from a script or a restored backup) was treated as true - for "Delete unknown objects on startup" that could have deleted objects including their history settings
857
+ * Handle an invalid host without crashing: neither the adapter start nor the App-Token dialog throws anymore, the dialog gets a proper error message and the adapter waits for a corrected configuration instead of restarting in a loop
858
+ * Give every adapter instance its own object helper. In compact mode two instances shared one helper, so the instance started last received the object and state writes of the other one
859
+ * Stop the request queue on unload. A control command arriving during the shutdown could otherwise queue new work and create a new timer after the DSS client was already closed
860
+ * Insert the login data of the App-Token dialog JSON safe. Passwords containing quotes, backslashes, line breaks or tabs broke the request
861
+ * Do not log the DSS username anymore
862
+ * Report a device that does not deliver an output value (e.g. a blind without tilt) once instead of warning after every scene - the value is re-read after each scene call
863
+ * Report requests aborted by the adapter stop as debug instead of flooding the log with warnings
864
+ * Update dependencies, remove manual Sentry integration (handled by the js-controller plugin), require Node.js >= 20, js-controller >= 6.0.11 and admin >= 7.6.17
865
+
866
+ ### 2.3.0 (2021-08-01)
867
+ * (Apollon77) Add support for use defined properties on apartment level
95
868
 
96
869
  ### 2.2.1 (2021-07-26)
97
870
  * (Apollon77) Optimize for js-controller 3.3
@@ -109,7 +882,7 @@ Best is to set the adapter to Debug log mode (Instances -> Expert mode -> Column
109
882
  * (Apollon77) BREAKING: binaryInput are now numbers intead of booleans because it can have values other then true/false
110
883
  * (Apollon77) BREAKING: Some states are converted to strings to allow all values to be passed
111
884
  * (Apollon77) Fixes on some outputValues
112
- * (Apollon77) add new sunelevation and sunazimuth values
885
+ * (Apollon77) add new sunelevation and sunazimuth values
113
886
 
114
887
  ### 1.0.2 (2020-02-10)
115
888
  * (Apollon77) trigger buttons on scene calls also if scene is normally not allowed but came from the device
@@ -138,7 +911,7 @@ Best is to set the adapter to Debug log mode (Instances -> Expert mode -> Column
138
911
  ### 0.4.9 (2020-01-18)
139
912
  * (Apollon77) add unknown weather sensor "windgust"
140
913
  * (Apollon77) change handling of Input types
141
- * (Apollon77) Fix controlling of shaders
914
+ * (Apollon77) Fix controlling of shaders
142
915
 
143
916
  ### 0.4.7 (2020-01-17)
144
917
  * (Apollon77) fix error when writing vdc output values
@@ -164,7 +937,7 @@ Best is to set the adapter to Debug log mode (Instances -> Expert mode -> Column
164
937
 
165
938
  ### 0.3.3 (2020-01-15)
166
939
  * (Apollon77) fixes for scene lists
167
- * (Apollon77) add some special szenes to more groups
940
+ * (Apollon77) add some special szenes to more groups
168
941
 
169
942
  ### 0.3.2 (2020-01-14)
170
943
  * (Apollon77) fixes for adapter start
@@ -201,6 +974,7 @@ Best is to set the adapter to Debug log mode (Instances -> Expert mode -> Column
201
974
  MIT License
202
975
 
203
976
  Copyright (c) 2020-2021 Apollon77 <iobroker@fischer-ka.de>
977
+ Copyright (c) 2026 André Schmitz (fork, maintenance and modifications)
204
978
 
205
979
  Permission is hereby granted, free of charge, to any person obtaining a copy
206
980
  of this software and associated documentation files (the "Software"), to deal