homematic-manager 3.0.0-beta.6 → 3.0.0-beta.7
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/testSupport.js +9 -2
- package/node_modules/@homematic-manager/backend/package.json +1 -1
- package/node_modules/@homematic-manager/core/dist/devices/index.d.ts +7 -0
- package/node_modules/@homematic-manager/core/dist/devices/index.js +7 -0
- package/node_modules/@homematic-manager/core/dist/rssi/index.d.ts +19 -0
- package/node_modules/@homematic-manager/core/dist/rssi/index.js +24 -0
- package/node_modules/@homematic-manager/core/package.json +1 -1
- package/package.json +3 -3
- package/ui/assets/index-CiQd11uV.js +14 -0
- package/ui/assets/{index-C99NI3-M.css → index-CkUznuX2.css} +1 -1
- package/ui/index.html +2 -2
- package/ui/assets/index-Mfj6d7fY.js +0 -14
package/dist/testSupport.js
CHANGED
|
@@ -183,7 +183,14 @@ export async function startForTest(options = {}) {
|
|
|
183
183
|
}
|
|
184
184
|
}
|
|
185
185
|
const ports = simulator
|
|
186
|
-
? {
|
|
186
|
+
? {
|
|
187
|
+
'BidCos-RF': simulator.ports.rfd,
|
|
188
|
+
'HmIP-RF': simulator.ports.hmip,
|
|
189
|
+
// only when the simulator was given a `virtualListenPort` (the CCU's group process)
|
|
190
|
+
...(typeof simulator.ports.virtual === 'number'
|
|
191
|
+
? { VirtualDevices: simulator.ports.virtual }
|
|
192
|
+
: {}),
|
|
193
|
+
}
|
|
187
194
|
: {};
|
|
188
195
|
const host = await createWebHost({
|
|
189
196
|
port: 0,
|
|
@@ -206,7 +213,7 @@ export async function startForTest(options = {}) {
|
|
|
206
213
|
if (simulator && host.backend) {
|
|
207
214
|
const connection = {
|
|
208
215
|
host: '127.0.0.1',
|
|
209
|
-
interfaces: ['BidCos-RF', 'HmIP-RF'],
|
|
216
|
+
interfaces: ['BidCos-RF', 'HmIP-RF', ...(ports['VirtualDevices'] === undefined ? [] : ['VirtualDevices'])],
|
|
210
217
|
autoDetect: false,
|
|
211
218
|
extraInterfaces: [],
|
|
212
219
|
tls: false,
|
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "@homematic-manager/backend",
|
|
3
|
-
"version": "3.0.0-beta.
|
|
3
|
+
"version": "3.0.0-beta.7",
|
|
4
4
|
"type": "module",
|
|
5
5
|
"description": "Homematic Manager backend: XML-RPC/BIN-RPC clients and callback servers, caches, optional ReGa",
|
|
6
6
|
"license": "AGPL-3.0-or-later",
|
|
@@ -72,6 +72,13 @@ export declare const RX_MODES: {
|
|
|
72
72
|
* by itself and one that does not (task 6).
|
|
73
73
|
*/
|
|
74
74
|
export declare function decodeRxMode(rxMode: number | undefined): string[];
|
|
75
|
+
/**
|
|
76
|
+
* Is roaming on for this device? rfd reports `ROAMING` as `1`/`0` over BIN-RPC and as a boolean
|
|
77
|
+
* over XML-RPC, so both spellings mean yes.
|
|
78
|
+
*/
|
|
79
|
+
export declare function isRoaming(device: {
|
|
80
|
+
readonly ROAMING?: boolean | number | undefined;
|
|
81
|
+
}): boolean;
|
|
75
82
|
/** `DIRECTION` of a channel. */
|
|
76
83
|
export declare const DIRECTIONS: readonly ["NONE", "SENDER", "RECEIVER"];
|
|
77
84
|
/** Decodes `DIRECTION`; anything unexpected is `NONE`, as the 2.x grid did. */
|
|
@@ -55,6 +55,13 @@ export function decodeRxMode(rxMode) {
|
|
|
55
55
|
}
|
|
56
56
|
return names;
|
|
57
57
|
}
|
|
58
|
+
/**
|
|
59
|
+
* Is roaming on for this device? rfd reports `ROAMING` as `1`/`0` over BIN-RPC and as a boolean
|
|
60
|
+
* over XML-RPC, so both spellings mean yes.
|
|
61
|
+
*/
|
|
62
|
+
export function isRoaming(device) {
|
|
63
|
+
return device.ROAMING === true || device.ROAMING === 1;
|
|
64
|
+
}
|
|
58
65
|
/** `DIRECTION` of a channel. */
|
|
59
66
|
export const DIRECTIONS = ['NONE', 'SENDER', 'RECEIVER'];
|
|
60
67
|
/** Decodes `DIRECTION`; anything unexpected is `NONE`, as the 2.x grid did. */
|
|
@@ -7,6 +7,7 @@
|
|
|
7
7
|
* as events and sit in every device's `<device>:0` VALUES paramset - the same thing 2.x does in
|
|
8
8
|
* main.js (:404-432 for the events, :800-822 for the paramset read).
|
|
9
9
|
*/
|
|
10
|
+
import type { BidcosInterfaceInfo } from '../api/types.js';
|
|
10
11
|
import type { Paramset, ParamsetValue } from '../rpc/values.js';
|
|
11
12
|
/** What an interface process sends instead of a value it does not have. */
|
|
12
13
|
export declare const RSSI_UNKNOWN = 65536;
|
|
@@ -41,6 +42,24 @@ export declare function rssiClass(dbm: number | undefined): RssiClass;
|
|
|
41
42
|
* `undefined` for a value there is none for - the cell stays empty, as it did.
|
|
42
43
|
*/
|
|
43
44
|
export declare function rssiColor(dbm: number | undefined): string | undefined;
|
|
45
|
+
/** The two fields of a `listBidcosInterfaces` entry that name it. */
|
|
46
|
+
export type BidcosInterfaceName = Pick<BidcosInterfaceInfo, 'ADDRESS' | 'DESCRIPTION'>;
|
|
47
|
+
/**
|
|
48
|
+
* How a BidCos interface is named for a person: the `DESCRIPTION` the CCU carries for it - the
|
|
49
|
+
* name a LAN gateway was given in the WebUI, `CCU2-Coprocessor` for the built-in module - and the
|
|
50
|
+
* serial when there is none. The 2.x Funk grid put the serial over the interface's columns with
|
|
51
|
+
* the description in small print under it; a gateway without a description shows its serial alone.
|
|
52
|
+
*/
|
|
53
|
+
export declare function bidcosInterfaceLabel(gateway: BidcosInterfaceName): string;
|
|
54
|
+
/**
|
|
55
|
+
* The receiver a BidCos-RF device is routed through, for the device grid (BUGS.md B-2): the
|
|
56
|
+
* label of the gateway whose serial the description's `INTERFACE` names, the serial itself when
|
|
57
|
+
* `listBidcosInterfaces` does not know it or has not been read yet, and nothing for a device
|
|
58
|
+
* without one - HmIP and Wired have no receivers.
|
|
59
|
+
*/
|
|
60
|
+
export declare function receiverLabel(device: {
|
|
61
|
+
readonly INTERFACE?: string | undefined;
|
|
62
|
+
}, gateways: readonly BidcosInterfaceName[]): string;
|
|
44
63
|
/** The HmIP datapoints the matrix is built from. */
|
|
45
64
|
export declare const RSSI_DATAPOINTS: readonly string[];
|
|
46
65
|
export interface RssiStoreOptions {
|
|
@@ -59,6 +59,30 @@ export function rssiColor(dbm) {
|
|
|
59
59
|
const green = channel((256 * (value - RSSI_BAD)) / (RSSI_MEDIUM - RSSI_BAD));
|
|
60
60
|
return `#${hex(red)}${hex(green)}00`;
|
|
61
61
|
}
|
|
62
|
+
/**
|
|
63
|
+
* How a BidCos interface is named for a person: the `DESCRIPTION` the CCU carries for it - the
|
|
64
|
+
* name a LAN gateway was given in the WebUI, `CCU2-Coprocessor` for the built-in module - and the
|
|
65
|
+
* serial when there is none. The 2.x Funk grid put the serial over the interface's columns with
|
|
66
|
+
* the description in small print under it; a gateway without a description shows its serial alone.
|
|
67
|
+
*/
|
|
68
|
+
export function bidcosInterfaceLabel(gateway) {
|
|
69
|
+
const description = gateway.DESCRIPTION?.trim() ?? '';
|
|
70
|
+
return description === '' ? gateway.ADDRESS : description;
|
|
71
|
+
}
|
|
72
|
+
/**
|
|
73
|
+
* The receiver a BidCos-RF device is routed through, for the device grid (BUGS.md B-2): the
|
|
74
|
+
* label of the gateway whose serial the description's `INTERFACE` names, the serial itself when
|
|
75
|
+
* `listBidcosInterfaces` does not know it or has not been read yet, and nothing for a device
|
|
76
|
+
* without one - HmIP and Wired have no receivers.
|
|
77
|
+
*/
|
|
78
|
+
export function receiverLabel(device, gateways) {
|
|
79
|
+
const serial = device.INTERFACE ?? '';
|
|
80
|
+
if (serial === '') {
|
|
81
|
+
return '';
|
|
82
|
+
}
|
|
83
|
+
const gateway = gateways.find((candidate) => candidate.ADDRESS === serial);
|
|
84
|
+
return gateway ? bidcosInterfaceLabel(gateway) : serial;
|
|
85
|
+
}
|
|
62
86
|
/** The HmIP datapoints the matrix is built from. */
|
|
63
87
|
export const RSSI_DATAPOINTS = ['RSSI_DEVICE', 'RSSI_PEER'];
|
|
64
88
|
/** The RSSI matrix of one interface. */
|
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "homematic-manager",
|
|
3
|
-
"version": "3.0.0-beta.
|
|
3
|
+
"version": "3.0.0-beta.7",
|
|
4
4
|
"type": "module",
|
|
5
5
|
"description": "Configure and administer Homematic and HomematicIP devices - devices and channels, direct links, paramsets, RSSI, service messages, events and an RPC console - from a local HTTP/WebSocket server that also serves the web UI",
|
|
6
6
|
"keywords": [
|
|
@@ -67,8 +67,8 @@
|
|
|
67
67
|
"hm-simulator": "^1.0.0"
|
|
68
68
|
},
|
|
69
69
|
"dependencies": {
|
|
70
|
-
"@homematic-manager/backend": "3.0.0-beta.
|
|
71
|
-
"@homematic-manager/core": "3.0.0-beta.
|
|
70
|
+
"@homematic-manager/backend": "3.0.0-beta.7",
|
|
71
|
+
"@homematic-manager/core": "3.0.0-beta.7",
|
|
72
72
|
"binrpc": "^4.2.0",
|
|
73
73
|
"homematic-rega": "^2.0.0",
|
|
74
74
|
"homematic-xmlrpc": "^2.0.0",
|