homebridge-tasmota-control 1.6.14 → 1.6.15-beta.1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -565,12 +565,6 @@
565
565
  6
566
566
  ]
567
567
  },
568
- {
569
- "title": "VANE H AUTO",
570
- "enum": [
571
- 10
572
- ]
573
- },
574
568
  {
575
569
  "title": "VANE H LEFT",
576
570
  "enum": [
@@ -692,19 +686,19 @@
692
686
  ]
693
687
  },
694
688
  {
695
- "title": "AIR DIRECTION EVEN (only as sensor now)",
689
+ "title": "AIR DIRECTION EVEN",
696
690
  "enum": [
697
691
  40
698
692
  ]
699
693
  },
700
694
  {
701
- "title": "AIR DIRECTION INDIRECT (only as sensor now)",
695
+ "title": "AIR DIRECTION INDIRECT",
702
696
  "enum": [
703
697
  41
704
698
  ]
705
699
  },
706
700
  {
707
- "title": "AIR DIRECTION DIRECT (only as sensor now)",
701
+ "title": "AIR DIRECTION DIRECT",
708
702
  "enum": [
709
703
  42
710
704
  ]
package/package.json CHANGED
@@ -1,7 +1,7 @@
1
1
  {
2
2
  "displayName": "Tasmota Control",
3
3
  "name": "homebridge-tasmota-control",
4
- "version": "1.6.14",
4
+ "version": "1.6.15-beta.1",
5
5
  "description": "Homebridge plugin to control Tasmota flashed devices.",
6
6
  "license": "MIT",
7
7
  "author": "grzegorz914",
package/src/constants.js CHANGED
@@ -55,19 +55,22 @@ export const MiElHVAC = {
55
55
  "swing": "HVACSetSwingV%20swing"
56
56
  },
57
57
  "SetSwingH": {
58
- "auto": "HVACSetSwingH%20auto",
59
58
  "left": "HVACSetSwingH%20left",
60
59
  "left_middle": "HVACSetSwingH%20left_middle",
61
60
  "center": "HVACSetSwingH%20center",
62
61
  "right_middle": "HVACSetSwingH%20right_middle",
63
62
  "right": "HVACSetSwingH%20right",
64
63
  "split": "HVACSetSwingH%20split",
65
- "swing": "HVACSetSwingH%20swing"
64
+ "swing": "HVACSetSwingH%20swing",
65
+ "even": "HVACSetSwingH%20even",
66
+ "indirect": "HVACSetSwingH%20indirect",
67
+ "direct": "HVACSetSwingH%20direct",
66
68
  },
67
69
  "SetAirDirection": {
68
- "even": "HVACSetAirDirection%20even",
69
- "indirect": "HVACSetAirDirection%20indirect",
70
- "direct": "HVACSetAirDirection%20direct"
70
+ "even": "HVACSetSwingH%20even",
71
+ "indirect": "HVACSetSwingH%20indirect",
72
+ "direct": "HVACSetSwingH%20direct",
73
+ "off": "HVACSetSwingH%20off"
71
74
  },
72
75
  "SetProhibit": {
73
76
  "off": "HVACSetProhibit%20off",
package/src/mielhvac.js CHANGED
@@ -455,9 +455,6 @@ class MiElHvac extends EventEmitter {
455
455
  case 6: //OPERATING MODE PURIFY
456
456
  button.state = power ? (operationMode === 'purify') : false;
457
457
  break;
458
- case 10: //VANE H AUTO
459
- button.state = power ? (vaneHorizontalDirection === 'auto') : false;
460
- break;
461
458
  case 11: //VANE H LEFT
462
459
  button.state = power ? (vaneHorizontalDirection === 'left') : false;
463
460
  break;
@@ -1179,10 +1176,6 @@ class MiElHvac extends EventEmitter {
1179
1176
  button.previousValue = state ? MiElHVAC.SetMode[this.mielHvac.operationMode] : button.previousValue;
1180
1177
  data = state ? MiElHVAC.SetMode.purify : button.previousValue;
1181
1178
  break;
1182
- case 10: //VANE H AUTO
1183
- button.previousValue = state ? MiElHVAC.SetSwingH[this.mielHvac.vaneHorizontalDirection] : button.previousValue;
1184
- data = state ? MiElHVAC.SetSwingH.auto : button.previousValue;
1185
- break;
1186
1179
  case 11: //VANE H LEFT
1187
1180
  button.previousValue = state ? MiElHVAC.SetSwingH[this.mielHvac.vaneHorizontalDirection] : button.previousValue;
1188
1181
  data = state ? MiElHVAC.SetSwingH.left : button.previousValue;