homebridge-philips-airplus-cloud 0.4.0 → 0.5.1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/CHANGELOG.md +9 -0
- package/README.md +3 -2
- package/config.schema.json +7 -0
- package/package.json +1 -1
- package/src/accessory.js +24 -3
- package/src/connection.js +44 -7
- package/src/constants.js +4 -1
package/CHANGELOG.md
CHANGED
|
@@ -2,6 +2,15 @@
|
|
|
2
2
|
|
|
3
3
|
The Home Assistant integration in `custom_components/` is unchanged from upstream and keeps its own history.
|
|
4
4
|
|
|
5
|
+
## 0.5.1 — 2026-11-21
|
|
6
|
+
|
|
7
|
+
- Fix: login and device discovery failed with HTTP 403 ("User is not authorized to access this resource…"). The Philips/Versuni API now rejects requests with the User-Agent the plugin used, `okhttp/4.12.0 (Android 14; Pixel 7)`, before even checking the login. The plugin now sends `okhttp/4.12.0`, as the upstream Home Assistant integration does since 1.1.7. The same API is used on every reconnect, so existing installations should update too.
|
|
8
|
+
|
|
9
|
+
## 0.5.0 — 2026-11-21
|
|
10
|
+
|
|
11
|
+
- New option **Filter alerts** (`filterAlerts`, default off): one contact sensor per filter, "Replace filter" and "Clean pre-filter", that opens when the filter drops to the alert threshold. The Home app never notifies about filter status, but it can notify when a contact sensor opens. A warning is also written to the Homebridge log.
|
|
12
|
+
- Fix: about once an hour, when the access token was renewed, the log showed "Not connected to the Philips cloud, command dropped" followed by "Connected to Philips cloud". During that reconnection the plugin still thought it was connected. HomeKit commands sent in that window are now queued and delivered as soon as the connection is back, status polls are skipped quietly, and the routine reconnection is logged at debug level only.
|
|
13
|
+
|
|
5
14
|
## 0.4.0 — 2026-10-25
|
|
6
15
|
|
|
7
16
|
- Added the Philips Air+ icon to the README.
|
package/README.md
CHANGED
|
@@ -5,11 +5,11 @@
|
|
|
5
5
|
</table>
|
|
6
6
|
<br />
|
|
7
7
|
|
|
8
|
-
 [](https://paypal.me/micheledipaola)
|
|
9
|
+
|
|
9
10
|
|
|
10
11
|
# homebridge-philips-airplus-cloud
|
|
11
12
|
|
|
12
|
-
[](https://paypal.me/micheledipaola)
|
|
13
13
|
|
|
14
14
|
Homebridge plugin for **Philips Air+** air purifiers (AC0650, AC0651, AC1715, PureProtect 3200i and others in the same family). It brings them into Apple Home through the Philips/Versuni **cloud**, with the same MQTT protocol used by the official Air+ app and Google Home. No local connection, IP address or port forwarding is needed.
|
|
15
15
|
|
|
@@ -91,6 +91,7 @@ The refresh token rotates on every use; the plugin keeps the current one in `<ho
|
|
|
91
91
|
| `airQualitySensor` | `true` | Show the PM2.5 sensor |
|
|
92
92
|
| `allergenSensor` | `true` | Show the allergen index as a second air quality sensor (models that report it) |
|
|
93
93
|
| `filterSensors` | `true` | Show filter and pre-filter status |
|
|
94
|
+
| `filterAlerts` | `false` | Add a contact sensor per filter that opens when it needs replacing / cleaning, so the Home app can notify you (turn on notifications for the sensors in Home) |
|
|
94
95
|
| `sleepSwitch` | `true` | Show the Sleep mode switch |
|
|
95
96
|
| `sleepSwitchStyle` | `switch` | `purifier` shows the Sleep control as a second air purifier (purifier icon in Home) that only turns Sleep on/off |
|
|
96
97
|
| `linkComponents` | `false` | Link Sleep, air quality and filters to the purifier. Off: each gets its own labelled tile in the purifier's combined view. On: Home shows them as controls inside the purifier, without labels |
|
package/config.schema.json
CHANGED
|
@@ -73,6 +73,12 @@
|
|
|
73
73
|
"type": "boolean",
|
|
74
74
|
"default": true
|
|
75
75
|
},
|
|
76
|
+
"filterAlerts": {
|
|
77
|
+
"title": "Filter alerts for Home notifications",
|
|
78
|
+
"type": "boolean",
|
|
79
|
+
"default": false,
|
|
80
|
+
"description": "Adds a contact sensor per filter ('Replace filter', 'Clean pre-filter') that opens when the filter needs attention, below the threshold set further down. In the Home app, turn on notifications for these sensors to be alerted."
|
|
81
|
+
},
|
|
76
82
|
"sleepSwitch": {
|
|
77
83
|
"title": "Show a Sleep mode switch",
|
|
78
84
|
"type": "boolean",
|
|
@@ -182,6 +188,7 @@
|
|
|
182
188
|
"airQualitySensor",
|
|
183
189
|
"allergenSensor",
|
|
184
190
|
"filterSensors",
|
|
191
|
+
"filterAlerts",
|
|
185
192
|
"sleepSwitch",
|
|
186
193
|
"sleepSwitchStyle",
|
|
187
194
|
"linkComponents",
|
package/package.json
CHANGED
|
@@ -1,7 +1,7 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "homebridge-philips-airplus-cloud",
|
|
3
3
|
"displayName": "Philips Air+",
|
|
4
|
-
"version": "0.
|
|
4
|
+
"version": "0.5.1",
|
|
5
5
|
"description": "Homebridge plugin for Philips Air+ / PureProtect air purifiers via the Philips (Versuni) cloud — the same MQTT protocol used by the Air+ app and Google Home.",
|
|
6
6
|
"main": "src/index.js",
|
|
7
7
|
"license": "MIT",
|
package/src/accessory.js
CHANGED
|
@@ -292,12 +292,24 @@ class PurifierAccessory {
|
|
|
292
292
|
|
|
293
293
|
// --- Filters
|
|
294
294
|
this.filters = {};
|
|
295
|
+
this.filterAlerts = {};
|
|
295
296
|
const filterDefs = [
|
|
296
|
-
{ kind: 'replace', subtype: 'filter', label: 'Filter' },
|
|
297
|
-
{ kind: 'clean', subtype: 'prefilter', label: 'Pre-filter' },
|
|
297
|
+
{ kind: 'replace', subtype: 'filter', label: 'Filter', alertLabel: 'Replace filter' },
|
|
298
|
+
{ kind: 'clean', subtype: 'prefilter', label: 'Pre-filter', alertLabel: 'Clean pre-filter' },
|
|
298
299
|
];
|
|
299
300
|
for (const f of filterDefs) {
|
|
300
301
|
const enabled = this._prop(`filter_${f.kind}_remaining`) && cfg.filterSensors !== false;
|
|
302
|
+
// filterAlerts: the Home app never notifies about filter status, but it
|
|
303
|
+
// can notify when a contact sensor opens. One sensor per filter, open
|
|
304
|
+
// while the filter needs replacing / cleaning.
|
|
305
|
+
const alertSubtype = `${f.subtype}-alert`;
|
|
306
|
+
if (enabled && cfg.filterAlerts === true) {
|
|
307
|
+
const a = this._service(Service.ContactSensor, f.alertLabel, alertSubtype);
|
|
308
|
+
a.getCharacteristic(Characteristic.ContactSensorState).onGet(() => this._filterChange(f.kind));
|
|
309
|
+
this.filterAlerts[f.kind] = a;
|
|
310
|
+
} else {
|
|
311
|
+
this._remove(Service.ContactSensor, alertSubtype);
|
|
312
|
+
}
|
|
301
313
|
if (!enabled) {
|
|
302
314
|
this._remove(Service.FilterMaintenance, f.subtype);
|
|
303
315
|
continue;
|
|
@@ -482,7 +494,8 @@ class PurifierAccessory {
|
|
|
482
494
|
// ------------------------------------------------------------ setters
|
|
483
495
|
|
|
484
496
|
_ensureConnected() {
|
|
485
|
-
|
|
497
|
+
// During the hourly token renewal the command is queued, not refused.
|
|
498
|
+
if (!this.conn.available) {
|
|
486
499
|
throw new this.api.hap.HapStatusError(this.hap.HAPStatus.SERVICE_COMMUNICATION_FAILURE);
|
|
487
500
|
}
|
|
488
501
|
}
|
|
@@ -715,6 +728,14 @@ class PurifierAccessory {
|
|
|
715
728
|
if (life === null) continue;
|
|
716
729
|
s.updateCharacteristic(Characteristic.FilterLifeLevel, life);
|
|
717
730
|
s.updateCharacteristic(Characteristic.FilterChangeIndication, this._filterChange(kind));
|
|
731
|
+
const alert = this.filterAlerts && this.filterAlerts[kind];
|
|
732
|
+
if (alert) {
|
|
733
|
+
const open = this._filterChange(kind); // 1 = CONTACT_NOT_DETECTED ("open")
|
|
734
|
+
if (alert.getCharacteristic(Characteristic.ContactSensorState).value !== open && open === 1) {
|
|
735
|
+
this.log.warn(`${kind === 'replace' ? 'Filter needs replacing' : 'Pre-filter needs cleaning'} (${life}% left)`);
|
|
736
|
+
}
|
|
737
|
+
alert.updateCharacteristic(Characteristic.ContactSensorState, open);
|
|
738
|
+
}
|
|
718
739
|
}
|
|
719
740
|
}
|
|
720
741
|
}
|
package/src/connection.js
CHANGED
|
@@ -118,6 +118,9 @@ class DeviceConnection extends EventEmitter {
|
|
|
118
118
|
|
|
119
119
|
async _connect() {
|
|
120
120
|
if (this.stopped) return;
|
|
121
|
+
// From here until the new connection is up, nothing can be published:
|
|
122
|
+
// user commands are queued, polls are skipped.
|
|
123
|
+
this.connected = false;
|
|
121
124
|
if (this.client) {
|
|
122
125
|
this.client.removeAllListeners();
|
|
123
126
|
this.client.on('error', () => {});
|
|
@@ -135,6 +138,7 @@ class DeviceConnection extends EventEmitter {
|
|
|
135
138
|
accessToken = this.account.accessToken;
|
|
136
139
|
clientId = buildClientId(await this.account.getUserId(), this.uuid);
|
|
137
140
|
} catch (e) {
|
|
141
|
+
this.reconnecting = false;
|
|
138
142
|
if (e instanceof AuthExpiredError) {
|
|
139
143
|
this.log.error(`${e.message}. The device stays offline until you log in again.`);
|
|
140
144
|
this.emit('authExpired');
|
|
@@ -173,7 +177,13 @@ class DeviceConnection extends EventEmitter {
|
|
|
173
177
|
this.attempt = 0;
|
|
174
178
|
this.lastMessageAt = Date.now();
|
|
175
179
|
client.subscribe(C.TOPIC_STATUS(this.deviceId), { qos: 0 });
|
|
176
|
-
|
|
180
|
+
// Routine reconnects (hourly token renewal) are logged at debug level.
|
|
181
|
+
if (!this.everConnected) this.log.info('Connected to Philips cloud');
|
|
182
|
+
else if (this.reconnecting) this.log.debug('Reconnected with the renewed access token');
|
|
183
|
+
else this.log.info('Reconnected to Philips cloud');
|
|
184
|
+
this.everConnected = true;
|
|
185
|
+
this.reconnecting = false;
|
|
186
|
+
this._flushQueue();
|
|
177
187
|
this.emit('connected');
|
|
178
188
|
});
|
|
179
189
|
|
|
@@ -203,6 +213,7 @@ class DeviceConnection extends EventEmitter {
|
|
|
203
213
|
if (client !== this.client || this.stopped) return;
|
|
204
214
|
const wasConnected = this.connected;
|
|
205
215
|
this.connected = false;
|
|
216
|
+
this.reconnecting = false; // a failed routine reconnect is a real outage
|
|
206
217
|
this.client = null;
|
|
207
218
|
const wait = this._backoff(client.__rc);
|
|
208
219
|
if (wasConnected) {
|
|
@@ -226,13 +237,39 @@ class DeviceConnection extends EventEmitter {
|
|
|
226
237
|
}
|
|
227
238
|
if (this.connected && this.tokenUsed !== this.account.accessToken) {
|
|
228
239
|
this.log.debug('Access token changed, reconnecting with new credentials');
|
|
240
|
+
this.reconnecting = true;
|
|
229
241
|
this._connect();
|
|
230
242
|
}
|
|
231
243
|
}
|
|
232
244
|
|
|
233
|
-
|
|
245
|
+
/** True while connected, or while a routine reconnect is in progress. */
|
|
246
|
+
get available() {
|
|
247
|
+
return this.connected || !!this.reconnecting;
|
|
248
|
+
}
|
|
249
|
+
|
|
250
|
+
_flushQueue() {
|
|
251
|
+
const now = Date.now();
|
|
252
|
+
const queue = (this.queue || []).filter((q) => now - q.at < 60000);
|
|
253
|
+
this.queue = [];
|
|
254
|
+
if (queue.length) this.log.debug(`Sending ${queue.length} command(s) queued during reconnection`);
|
|
255
|
+
for (const q of queue) this.client.publish(q.topic, q.payload, { qos: q.qos });
|
|
256
|
+
}
|
|
257
|
+
|
|
258
|
+
/**
|
|
259
|
+
* @param {boolean} [queue] user commands: kept for up to 60 s while the
|
|
260
|
+
* connection is being re-established instead of being dropped. Status
|
|
261
|
+
* requests are not queued: they are repeated on every (re)connect anyway.
|
|
262
|
+
*/
|
|
263
|
+
_publish(topic, payload, qos = 0, queue = false) {
|
|
234
264
|
if (!this.client || !this.connected) {
|
|
235
|
-
|
|
265
|
+
if (queue && !this.stopped) {
|
|
266
|
+
this.queue = (this.queue || []).slice(-19);
|
|
267
|
+
this.queue.push({ topic, payload, qos, at: Date.now() });
|
|
268
|
+
this.log.debug('Not connected right now, command queued until the connection is back');
|
|
269
|
+
return true;
|
|
270
|
+
}
|
|
271
|
+
if (this.reconnecting) this.log.debug('Reconnecting, status request skipped');
|
|
272
|
+
else this.log.warn('Not connected to the Philips cloud, command dropped');
|
|
236
273
|
return false;
|
|
237
274
|
}
|
|
238
275
|
this.log.debug(`MQTT -> ${topic} ${payload}`);
|
|
@@ -245,8 +282,8 @@ class DeviceConnection extends EventEmitter {
|
|
|
245
282
|
}
|
|
246
283
|
|
|
247
284
|
setPort(port, properties, qos = 0) {
|
|
248
|
-
const ok = this._publish(C.TOPIC_CONTROL(this.deviceId), buildCommand('setPort', port, properties), qos);
|
|
249
|
-
if (ok) this.getPort(port === this.ports.filter_write ? this.ports.filter_read : this.ports.status);
|
|
285
|
+
const ok = this._publish(C.TOPIC_CONTROL(this.deviceId), buildCommand('setPort', port, properties), qos, true);
|
|
286
|
+
if (ok && this.connected) this.getPort(port === this.ports.filter_write ? this.ports.filter_read : this.ports.status);
|
|
250
287
|
return ok;
|
|
251
288
|
}
|
|
252
289
|
|
|
@@ -255,8 +292,8 @@ class DeviceConnection extends EventEmitter {
|
|
|
255
292
|
}
|
|
256
293
|
|
|
257
294
|
setPower(on) {
|
|
258
|
-
const ok = this._publish(C.TOPIC_SHADOW_UPDATE(this.deviceId), JSON.stringify({ state: { desired: { powerOn: !!on } } }));
|
|
259
|
-
if (ok) this.getPort(this.ports.status);
|
|
295
|
+
const ok = this._publish(C.TOPIC_SHADOW_UPDATE(this.deviceId), JSON.stringify({ state: { desired: { powerOn: !!on } } }), 0, true);
|
|
296
|
+
if (ok && this.connected) this.getPort(this.ports.status);
|
|
260
297
|
return ok;
|
|
261
298
|
}
|
|
262
299
|
|
package/src/constants.js
CHANGED
|
@@ -12,7 +12,10 @@ const DEVICE_ENDPOINT = `${API_BASE_URL}/da/user/self/device`;
|
|
|
12
12
|
const SIGNATURE_ENDPOINT = `${API_BASE_URL}/da/user/self/signature`;
|
|
13
13
|
const USER_SELF_ENDPOINT = `${API_BASE_URL}/da/user/self`;
|
|
14
14
|
|
|
15
|
-
|
|
15
|
+
// "okhttp/4.12.0 (Android 14; Pixel 7)" is rejected with HTTP 403 by the
|
|
16
|
+
// DaConnect API (before authentication), so do not use it. Same fix as
|
|
17
|
+
// upstream NikGro/philips-air-plus-homeassistant 2a9cfe3.
|
|
18
|
+
const HTTP_USER_AGENT = 'okhttp/4.12.0';
|
|
16
19
|
|
|
17
20
|
const GIGYA_API_KEY = '4_JGZWlP8eQHpEqkvQElolbA';
|
|
18
21
|
const GIGYA_API_URL = 'https://cdc.accounts.home.id';
|