homebridge-nuheat2 1.2.28 → 1.4.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/CHANGELOG.md +24 -0
- package/README.md +18 -0
- package/config.schema.json +7 -0
- package/homebridge-ui/public/index.html +13 -0
- package/homebridge-ui/public/index.js +18 -0
- package/index.js +1 -1
- package/lib/NuHeatAPI.js +65 -3
- package/lib/NuHeatGroup.js +4 -1
- package/lib/NuHeatModels.js +76 -1
- package/lib/NuHeatThermostat.js +97 -17
- package/package.json +1 -1
package/CHANGELOG.md
CHANGED
|
@@ -4,6 +4,30 @@ All notable changes to this project should be documented in this file
|
|
|
4
4
|
|
|
5
5
|
## [Unreleased]
|
|
6
6
|
|
|
7
|
+
## [1.4.0] - 2026-10-17
|
|
8
|
+
|
|
9
|
+
### Fixed
|
|
10
|
+
|
|
11
|
+
- Report a requested `Off` back to HomeKit as `Off`: standby is now derived from a manual or hold mode parked at the minimum target temperature, so the Home app no longer bounces the tile back to `Heat` after turning a thermostat off
|
|
12
|
+
- Stop treating an auto schedule combined with a manual operating mode as `Off`; an auto schedule is always a scheduled run and is reported as `Auto`
|
|
13
|
+
- Fail gracefully when a Nuheat API or OAuth token response is not valid JSON instead of throwing an unhandled parse error
|
|
14
|
+
- Acknowledge failed away-mode switch writes and re-read the group so the switch reconciles with the real state instead of wedging the Home app
|
|
15
|
+
|
|
16
|
+
## [1.3.0] - 2026-10-15
|
|
17
|
+
|
|
18
|
+
### Added
|
|
19
|
+
|
|
20
|
+
- Opt-in `enableThermostatModeControl` setting that adds `Off` and `Auto` target states to each thermostat and routes those requests through Nuheat's v2 mode API (`PUT /api/v2/Mode/Manual`, `Mode/Hold`, `Mode/Auto`). Defaults to `false`, so existing installations keep advertising heat only
|
|
21
|
+
|
|
22
|
+
### Changed
|
|
23
|
+
|
|
24
|
+
- Derive the HomeKit target state from Nuheat's `operatingMode`/`scheduleMode` fields, replacing a switch that returned `Heat` in every branch
|
|
25
|
+
|
|
26
|
+
### Fixed
|
|
27
|
+
|
|
28
|
+
- Stop pushing the empty `204 No Content` response from setpoint writes into HomeKit, which briefly flashed `0.2 C` / `10 C` readings and a wrong target state after every change; write paths now re-read the thermostat and non-object payloads are ignored
|
|
29
|
+
- Stop sending a stale cached setpoint with heat-mode requests, which could silently clobber a concurrent setpoint write from the Home app; heat requests now omit the optional temperature field
|
|
30
|
+
|
|
7
31
|
## [1.2.28] - 2026-09-14
|
|
8
32
|
|
|
9
33
|
### Fixed
|
package/README.md
CHANGED
|
@@ -64,6 +64,7 @@ The equivalent JSON looks like this:
|
|
|
64
64
|
"groups": [{ "groupName": "Main Floor", "disabled": false }],
|
|
65
65
|
"exposeScheduleSwitches": false,
|
|
66
66
|
"enableNotifications": true,
|
|
67
|
+
"enableThermostatModeControl": false,
|
|
67
68
|
"holdLength": 1440,
|
|
68
69
|
"refresh": 60
|
|
69
70
|
}
|
|
@@ -86,6 +87,7 @@ The equivalent JSON looks like this:
|
|
|
86
87
|
- `holdLength`: Hold duration in minutes, default `1440`. Values are clamped from `0` to `1440`
|
|
87
88
|
- `refresh`: Poll interval in seconds, default `60`. Values lower than `30` are raised to `30` to reduce API traffic
|
|
88
89
|
- `enableNotifications`: Enables Nuheat SignalR notifications for faster updates. Defaults to `true`; set to `false` only while troubleshooting
|
|
90
|
+
- `enableThermostatModeControl`: Adds `Off` and `Auto` target states to each thermostat so HomeKit can request standby or resume the schedule. Defaults to `false`. Experimental; see [Thermostat Mode Control](#thermostat-mode-control)
|
|
89
91
|
- `debug`: Enables verbose Nuheat API, notification, and accessory logging. Defaults to `false`
|
|
90
92
|
|
|
91
93
|
### Hold Length Behavior
|
|
@@ -102,6 +104,22 @@ What the thermostats do while a group is in away mode is decided by Nuheat's ser
|
|
|
102
104
|
|
|
103
105
|
If you need a specific temperature held while you are away, set that temperature on the thermostat itself. The plugin will hold it for `holdLength` minutes, or permanently when `holdLength` is `1440`.
|
|
104
106
|
|
|
107
|
+
### Thermostat Mode Control
|
|
108
|
+
|
|
109
|
+
By default each thermostat advertises only `Heat` as a target state, because Nuheat's v1 thermostat update API has no operating-mode field and therefore cannot request standby.
|
|
110
|
+
|
|
111
|
+
Setting `enableThermostatModeControl` to `true` adds `Off` and `Auto` to the target states and routes those requests through Nuheat's v2 mode API:
|
|
112
|
+
|
|
113
|
+
| HomeKit target | Nuheat v2 request |
|
|
114
|
+
| --- | --- |
|
|
115
|
+
| `Off` | `PUT /api/v2/Mode/Manual` at the minimum target temperature (10 °C / 50 °F) |
|
|
116
|
+
| `Heat` | `PUT /api/v2/Mode/Hold` at the current target temperature, or `Mode/Manual` when `holdLength` is `1440` |
|
|
117
|
+
| `Auto` | `PUT /api/v2/Mode/Auto`, resuming the schedule |
|
|
118
|
+
|
|
119
|
+
Reads still come from the v1 API, which is the only version that reports `groupId` (needed for away mode) and `operatingMode`/`scheduleMode`. The plugin derives the HomeKit target state from those fields: a manual or hold mode parked at the minimum target temperature is reported as `Off` (Nuheat's Standby — exactly how this plugin requests it), a warmer manual or hold setpoint is reported as `Heat`, and an auto schedule is reported as `Auto` regardless of the thermostat's operating mode.
|
|
120
|
+
|
|
121
|
+
Nuheat has no explicit "off" concept, so `Off` is implemented as a permanent manual setpoint at the minimum temperature, and reads recognize that state by the parked setpoint. Mode writes through the v2 mode API are reflected in subsequent v1 reads, so a requested `Off` reads back as `Off`.
|
|
122
|
+
|
|
105
123
|
### Device Discovery
|
|
106
124
|
|
|
107
125
|
If `devices` is omitted or empty, the plugin will automatically expose every thermostat on the authenticated account.
|
package/config.schema.json
CHANGED
|
@@ -95,6 +95,12 @@
|
|
|
95
95
|
"default": false,
|
|
96
96
|
"description": "Create one switch per thermostat. The switch is on when the thermostat follows its Nuheat schedule and can be turned on to resume the schedule."
|
|
97
97
|
},
|
|
98
|
+
"enableThermostatModeControl": {
|
|
99
|
+
"title": "Enable Thermostat Mode Control (Off/Auto)",
|
|
100
|
+
"type": "boolean",
|
|
101
|
+
"default": false,
|
|
102
|
+
"description": "Adds Off and Auto target states to each thermostat using Nuheat's v2 mode API, so HomeKit can request standby or resume the schedule. Experimental: leave disabled unless you want HomeKit to drive thermostat mode."
|
|
103
|
+
},
|
|
98
104
|
"holdLength": {
|
|
99
105
|
"title": "Hold Length (minutes)",
|
|
100
106
|
"type": "integer",
|
|
@@ -152,6 +158,7 @@
|
|
|
152
158
|
"holdLength",
|
|
153
159
|
"refresh",
|
|
154
160
|
"enableNotifications",
|
|
161
|
+
"enableThermostatModeControl",
|
|
155
162
|
"debug"
|
|
156
163
|
]
|
|
157
164
|
}
|
|
@@ -146,6 +146,19 @@
|
|
|
146
146
|
</span>
|
|
147
147
|
</label>
|
|
148
148
|
|
|
149
|
+
<label class="checkbox">
|
|
150
|
+
<input id="enable-thermostat-mode-control" type="checkbox" />
|
|
151
|
+
<span>
|
|
152
|
+
Enable thermostat mode control (Off / Auto)
|
|
153
|
+
<small>
|
|
154
|
+
Adds Off and Auto target states to each thermostat using Nuheat's v2
|
|
155
|
+
mode API, so HomeKit can request standby or resume the schedule.
|
|
156
|
+
Experimental; leave off unless you want HomeKit to drive thermostat
|
|
157
|
+
mode.
|
|
158
|
+
</small>
|
|
159
|
+
</span>
|
|
160
|
+
</label>
|
|
161
|
+
|
|
149
162
|
<label class="checkbox">
|
|
150
163
|
<input id="debug" type="checkbox" />
|
|
151
164
|
<span>
|
|
@@ -12,6 +12,9 @@ const elements = {
|
|
|
12
12
|
holdLength: document.getElementById("hold-length"),
|
|
13
13
|
refresh: document.getElementById("refresh"),
|
|
14
14
|
enableNotifications: document.getElementById("enable-notifications"),
|
|
15
|
+
enableThermostatModeControl: document.getElementById(
|
|
16
|
+
"enable-thermostat-mode-control",
|
|
17
|
+
),
|
|
15
18
|
debug: document.getElementById("debug"),
|
|
16
19
|
saveAccount: document.getElementById("save-account"),
|
|
17
20
|
addDevice: document.getElementById("add-device"),
|
|
@@ -102,6 +105,7 @@ function createDefaultConfig() {
|
|
|
102
105
|
autoPopulateAwayModeSwitches: false,
|
|
103
106
|
exposeScheduleSwitches: false,
|
|
104
107
|
enableNotifications: true,
|
|
108
|
+
enableThermostatModeControl: false,
|
|
105
109
|
holdLength: 1440,
|
|
106
110
|
refresh: 60,
|
|
107
111
|
debug: false,
|
|
@@ -126,6 +130,9 @@ function renderConfig(config) {
|
|
|
126
130
|
elements.holdLength.value = String(normalizeHoldLength(config.holdLength));
|
|
127
131
|
elements.refresh.value = String(normalizeRefresh(config.refresh));
|
|
128
132
|
elements.enableNotifications.checked = config.enableNotifications !== false;
|
|
133
|
+
elements.enableThermostatModeControl.checked = Boolean(
|
|
134
|
+
config.enableThermostatModeControl,
|
|
135
|
+
);
|
|
129
136
|
elements.debug.checked = Boolean(config.debug);
|
|
130
137
|
|
|
131
138
|
updateStatuses();
|
|
@@ -313,6 +320,9 @@ async function saveBehavior() {
|
|
|
313
320
|
holdLength,
|
|
314
321
|
refresh,
|
|
315
322
|
enableNotifications: Boolean(elements.enableNotifications.checked),
|
|
323
|
+
enableThermostatModeControl: Boolean(
|
|
324
|
+
elements.enableThermostatModeControl.checked,
|
|
325
|
+
),
|
|
316
326
|
debug: Boolean(elements.debug.checked),
|
|
317
327
|
});
|
|
318
328
|
showToast("success", "Behavior settings saved.");
|
|
@@ -438,6 +448,10 @@ function renderDiagnostics() {
|
|
|
438
448
|
"Notifications",
|
|
439
449
|
config.enableNotifications === false ? "disabled" : "enabled",
|
|
440
450
|
],
|
|
451
|
+
[
|
|
452
|
+
"Mode Control",
|
|
453
|
+
config.enableThermostatModeControl ? "Off / Auto enabled" : "heat only",
|
|
454
|
+
],
|
|
441
455
|
["Debug Logs", config.debug ? "enabled" : "disabled"],
|
|
442
456
|
]);
|
|
443
457
|
}
|
|
@@ -475,6 +489,9 @@ function getDraftConfig() {
|
|
|
475
489
|
holdLength: normalizeHoldLength(elements.holdLength.value),
|
|
476
490
|
refresh: normalizeRefresh(elements.refresh.value),
|
|
477
491
|
enableNotifications: Boolean(elements.enableNotifications.checked),
|
|
492
|
+
enableThermostatModeControl: Boolean(
|
|
493
|
+
elements.enableThermostatModeControl.checked,
|
|
494
|
+
),
|
|
478
495
|
debug: Boolean(elements.debug.checked),
|
|
479
496
|
};
|
|
480
497
|
}
|
|
@@ -568,6 +585,7 @@ function bindEvents() {
|
|
|
568
585
|
elements.holdLength,
|
|
569
586
|
elements.refresh,
|
|
570
587
|
elements.enableNotifications,
|
|
588
|
+
elements.enableThermostatModeControl,
|
|
571
589
|
elements.debug,
|
|
572
590
|
].forEach((element) => {
|
|
573
591
|
element.addEventListener("input", () => {
|
package/index.js
CHANGED
|
@@ -192,7 +192,7 @@ class NuHeatPlatform {
|
|
|
192
192
|
entry = { uuid };
|
|
193
193
|
this.accessories.push(entry);
|
|
194
194
|
}
|
|
195
|
-
entry.accessory = new NuHeatThermostat(this.log, deviceData, this.config.holdLength || 1440, getPlatformAccessory(deviceAccessory), this.NuHeatAPI, Homebridge, this.account?.temperatureScale);
|
|
195
|
+
entry.accessory = new NuHeatThermostat(this.log, deviceData, this.config.holdLength || 1440, getPlatformAccessory(deviceAccessory), this.NuHeatAPI, Homebridge, this.account?.temperatureScale, this.config.enableThermostatModeControl === true);
|
|
196
196
|
entry.existsInConfig = true;
|
|
197
197
|
this.log.info("Loaded thermostat " +
|
|
198
198
|
deviceData.serialNumber +
|
package/lib/NuHeatAPI.js
CHANGED
|
@@ -163,6 +163,42 @@ class NuHeatAPI {
|
|
|
163
163
|
scheduleMode: NuHeatModels_1.SCHEDULE_MODE.AUTO,
|
|
164
164
|
});
|
|
165
165
|
}
|
|
166
|
+
/**
|
|
167
|
+
* The v1 thermostat update model has no operating mode, so it cannot request
|
|
168
|
+
* standby. The v2 mode endpoints can, and they share the same account,
|
|
169
|
+
* identity provider, and `openapi` scope as v1.
|
|
170
|
+
*/
|
|
171
|
+
async setThermostatMode(serialNumber, mode, options = {}) {
|
|
172
|
+
let callURL;
|
|
173
|
+
const callBody = { serialNumber };
|
|
174
|
+
if (mode === NuHeatModels_1.HEATING_MODE.AUTO) {
|
|
175
|
+
callURL = (0, settings_1.buildNuHeatApiUrl)("/api/v2/Mode/Auto");
|
|
176
|
+
}
|
|
177
|
+
else if (mode === NuHeatModels_1.HEATING_MODE.HOLD) {
|
|
178
|
+
callURL = (0, settings_1.buildNuHeatApiUrl)("/api/v2/Mode/Hold");
|
|
179
|
+
if (options.holdLength && options.holdLength > 0) {
|
|
180
|
+
callBody.holdUntil = new Date(Date.now() + options.holdLength * 60 * 1000).toISOString();
|
|
181
|
+
}
|
|
182
|
+
}
|
|
183
|
+
else {
|
|
184
|
+
// NuHeat has no off; standby is a permanent manual setpoint.
|
|
185
|
+
callURL = (0, settings_1.buildNuHeatApiUrl)("/api/v2/Mode/Manual");
|
|
186
|
+
}
|
|
187
|
+
if (options.setPointTemp !== undefined) {
|
|
188
|
+
callBody.temperature = Number(options.setPointTemp);
|
|
189
|
+
callBody.temperatureType = NuHeatModels_1.TEMPERATURE_TYPE.ABSOLUTE;
|
|
190
|
+
}
|
|
191
|
+
this.log.debug("NuHeatAPI: Setting thermostat " +
|
|
192
|
+
serialNumber +
|
|
193
|
+
" to " +
|
|
194
|
+
mode +
|
|
195
|
+
" mode.");
|
|
196
|
+
const callOptions = {
|
|
197
|
+
body: JSON.stringify(callBody),
|
|
198
|
+
method: "PUT",
|
|
199
|
+
};
|
|
200
|
+
return await this.makeAPICall(callURL, callOptions);
|
|
201
|
+
}
|
|
166
202
|
async updateThermostat(thermostatUpdate) {
|
|
167
203
|
const callURL = (0, settings_1.buildNuHeatApiUrl)("/api/v1/Thermostat");
|
|
168
204
|
const callOptions = {
|
|
@@ -254,7 +290,17 @@ class NuHeatAPI {
|
|
|
254
290
|
if (response.status === 204) {
|
|
255
291
|
return true;
|
|
256
292
|
}
|
|
257
|
-
|
|
293
|
+
let returnedData;
|
|
294
|
+
try {
|
|
295
|
+
returnedData = await response.json();
|
|
296
|
+
}
|
|
297
|
+
catch (error) {
|
|
298
|
+
this.log.warn("NuHeatAPI: " +
|
|
299
|
+
this.describeRequest(callURL, callOptions) +
|
|
300
|
+
" returned a response that could not be parsed as JSON: " +
|
|
301
|
+
error);
|
|
302
|
+
return false;
|
|
303
|
+
}
|
|
258
304
|
if (options.normalize) {
|
|
259
305
|
if (options.normalizeArray && Array.isArray(returnedData)) {
|
|
260
306
|
return returnedData.map(options.normalize);
|
|
@@ -589,7 +635,15 @@ class NuHeatAPI {
|
|
|
589
635
|
return null;
|
|
590
636
|
}
|
|
591
637
|
this.tokenScope = redirectUrl.searchParams.get("scope") ?? "";
|
|
592
|
-
|
|
638
|
+
let token;
|
|
639
|
+
try {
|
|
640
|
+
token = (await response.json());
|
|
641
|
+
}
|
|
642
|
+
catch (error) {
|
|
643
|
+
this.log.warn("NuHeatAPI: The OAuth token response could not be parsed as JSON: " +
|
|
644
|
+
error);
|
|
645
|
+
return null;
|
|
646
|
+
}
|
|
593
647
|
this.log.debug("NuHeatAPI: OAuth access token received. Granted scopes: " +
|
|
594
648
|
(token.scope || this.tokenScope || "unknown") +
|
|
595
649
|
". Refresh token present: " +
|
|
@@ -610,7 +664,15 @@ class NuHeatAPI {
|
|
|
610
664
|
if (!response) {
|
|
611
665
|
return false;
|
|
612
666
|
}
|
|
613
|
-
|
|
667
|
+
let token;
|
|
668
|
+
try {
|
|
669
|
+
token = (await response.json());
|
|
670
|
+
}
|
|
671
|
+
catch (error) {
|
|
672
|
+
this.log.warn("NuHeatAPI: The refreshed OAuth token response could not be parsed as JSON: " +
|
|
673
|
+
error);
|
|
674
|
+
return false;
|
|
675
|
+
}
|
|
614
676
|
const previousRefreshToken = this.refreshToken;
|
|
615
677
|
this.accessToken = token.access_token;
|
|
616
678
|
this.accessTokenTimestamp = Date.now();
|
package/lib/NuHeatGroup.js
CHANGED
|
@@ -31,7 +31,10 @@ class NuHeatGroup {
|
|
|
31
31
|
const response = await this.NuHeatAPI.setAwayMode(this.deviceData.groupId ?? "", value);
|
|
32
32
|
if (!response) {
|
|
33
33
|
this.log.error("Error setting away mode", this.deviceData.groupName);
|
|
34
|
-
|
|
34
|
+
// Acknowledge the write so HomeKit does not wedge the switch, then
|
|
35
|
+
// re-read the group to reconcile the tile with the real state.
|
|
36
|
+
callback(null);
|
|
37
|
+
await this.updateAccessory();
|
|
35
38
|
}
|
|
36
39
|
else {
|
|
37
40
|
this.updateValues({ ...this.deviceData, awayMode: value });
|
package/lib/NuHeatModels.js
CHANGED
|
@@ -1,6 +1,10 @@
|
|
|
1
1
|
"use strict";
|
|
2
2
|
Object.defineProperty(exports, "__esModule", { value: true });
|
|
3
|
-
exports.OPERATING_MODE = exports.SCHEDULE_MODE = void 0;
|
|
3
|
+
exports.STANDBY_SETPOINT_C = exports.TEMPERATURE_TYPE = exports.HEATING_MODE = exports.OPERATING_MODE = exports.SCHEDULE_MODE = void 0;
|
|
4
|
+
exports.isThermostatOnline = isThermostatOnline;
|
|
5
|
+
exports.fromNuHeatTemperature = fromNuHeatTemperature;
|
|
6
|
+
exports.isStandbySetpoint = isStandbySetpoint;
|
|
7
|
+
exports.deriveHeatingMode = deriveHeatingMode;
|
|
4
8
|
exports.normalizeAccount = normalizeAccount;
|
|
5
9
|
exports.normalizeGroup = normalizeGroup;
|
|
6
10
|
exports.normalizeSchedule = normalizeSchedule;
|
|
@@ -15,9 +19,80 @@ exports.OPERATING_MODE = {
|
|
|
15
19
|
AUTO: 1,
|
|
16
20
|
MANUAL: 2,
|
|
17
21
|
};
|
|
22
|
+
exports.HEATING_MODE = {
|
|
23
|
+
OFF: "off",
|
|
24
|
+
MANUAL: "manual",
|
|
25
|
+
HOLD: "hold",
|
|
26
|
+
AUTO: "auto",
|
|
27
|
+
};
|
|
28
|
+
/** v2 `eTemperatureType`: 0 = absolute setpoint, 1 = relative to current. */
|
|
29
|
+
exports.TEMPERATURE_TYPE = {
|
|
30
|
+
ABSOLUTE: 0,
|
|
31
|
+
RELATIVE: 1,
|
|
32
|
+
};
|
|
18
33
|
function coalesce(...values) {
|
|
19
34
|
return values.find((value) => value !== undefined && value !== null);
|
|
20
35
|
}
|
|
36
|
+
function isThermostatOnline(thermostat) {
|
|
37
|
+
const onlineValue = coalesce(thermostat.Online, thermostat.online, thermostat.isOnline);
|
|
38
|
+
if (typeof onlineValue === "boolean") {
|
|
39
|
+
return onlineValue;
|
|
40
|
+
}
|
|
41
|
+
if (typeof onlineValue === "string") {
|
|
42
|
+
return onlineValue.replace(/'/g, "").trim().toLowerCase() === "true";
|
|
43
|
+
}
|
|
44
|
+
return true;
|
|
45
|
+
}
|
|
46
|
+
/** The minimum NuHeat target temperature, which the plugin uses for standby. */
|
|
47
|
+
exports.STANDBY_SETPOINT_C = 10;
|
|
48
|
+
/** Converts a raw NuHeat temperature (e.g. `setPointTemp`) to Celsius. */
|
|
49
|
+
function fromNuHeatTemperature(raw) {
|
|
50
|
+
return (((raw - 33) / 56 + 33 - 32) * 5) / 9;
|
|
51
|
+
}
|
|
52
|
+
/**
|
|
53
|
+
* Standby is a manual or hold mode parked at the minimum target temperature,
|
|
54
|
+
* which is how this plugin requests it. Away mode reads back even lower, so
|
|
55
|
+
* anything at or below the standby setpoint counts.
|
|
56
|
+
*/
|
|
57
|
+
function isStandbySetpoint(setPointTemp) {
|
|
58
|
+
if (setPointTemp === undefined || setPointTemp === null) {
|
|
59
|
+
return false;
|
|
60
|
+
}
|
|
61
|
+
const celsius = fromNuHeatTemperature(Number(setPointTemp));
|
|
62
|
+
return Number.isFinite(celsius) && celsius <= exports.STANDBY_SETPOINT_C;
|
|
63
|
+
}
|
|
64
|
+
/**
|
|
65
|
+
* NuHeat has no "off". Standby is a manual or hold mode parked at the minimum
|
|
66
|
+
* target temperature; a genuine manual setpoint change always reads back
|
|
67
|
+
* warmer, and an auto schedule is a scheduled run regardless of the
|
|
68
|
+
* thermostat's operating mode.
|
|
69
|
+
*/
|
|
70
|
+
function deriveHeatingMode(thermostat) {
|
|
71
|
+
if (!isThermostatOnline(thermostat)) {
|
|
72
|
+
return exports.HEATING_MODE.OFF;
|
|
73
|
+
}
|
|
74
|
+
const scheduleMode = Number(thermostat.scheduleMode);
|
|
75
|
+
if (scheduleMode === exports.SCHEDULE_MODE.HOLD) {
|
|
76
|
+
return isStandbySetpoint(thermostat.setPointTemp)
|
|
77
|
+
? exports.HEATING_MODE.OFF
|
|
78
|
+
: exports.HEATING_MODE.HOLD;
|
|
79
|
+
}
|
|
80
|
+
if (scheduleMode === exports.SCHEDULE_MODE.PERMANENT_HOLD) {
|
|
81
|
+
return isStandbySetpoint(thermostat.setPointTemp)
|
|
82
|
+
? exports.HEATING_MODE.OFF
|
|
83
|
+
: exports.HEATING_MODE.MANUAL;
|
|
84
|
+
}
|
|
85
|
+
if (scheduleMode === exports.SCHEDULE_MODE.AUTO) {
|
|
86
|
+
return exports.HEATING_MODE.AUTO;
|
|
87
|
+
}
|
|
88
|
+
// Unknown schedule mode: report whatever the hardware tells us.
|
|
89
|
+
if (Number(thermostat.operatingMode) === exports.OPERATING_MODE.MANUAL) {
|
|
90
|
+
return isStandbySetpoint(thermostat.setPointTemp)
|
|
91
|
+
? exports.HEATING_MODE.OFF
|
|
92
|
+
: exports.HEATING_MODE.MANUAL;
|
|
93
|
+
}
|
|
94
|
+
return exports.HEATING_MODE.AUTO;
|
|
95
|
+
}
|
|
21
96
|
function normalizeAccount(account = {}) {
|
|
22
97
|
return {
|
|
23
98
|
firstName: coalesce(account.firstName, account.FirstName),
|
package/lib/NuHeatThermostat.js
CHANGED
|
@@ -2,7 +2,6 @@
|
|
|
2
2
|
const NuHeatModels_1 = require("./NuHeatModels");
|
|
3
3
|
let Characteristic;
|
|
4
4
|
let ThermostatService;
|
|
5
|
-
const MIN_TARGET_TEMPERATURE_C = 10;
|
|
6
5
|
const MAX_TARGET_TEMPERATURE_C = 38;
|
|
7
6
|
class NuHeatThermostat {
|
|
8
7
|
log;
|
|
@@ -11,7 +10,8 @@ class NuHeatThermostat {
|
|
|
11
10
|
accessory;
|
|
12
11
|
NuHeatAPI;
|
|
13
12
|
temperatureScale;
|
|
14
|
-
|
|
13
|
+
enableThermostatModeControl;
|
|
14
|
+
constructor(log, deviceData, holdLength, accessory, NuHeatAPI, homebridge, temperatureScale, enableThermostatModeControl = false) {
|
|
15
15
|
Characteristic = homebridge.hap.Characteristic;
|
|
16
16
|
ThermostatService = homebridge.hap.Service.Thermostat;
|
|
17
17
|
this.log = log;
|
|
@@ -20,6 +20,7 @@ class NuHeatThermostat {
|
|
|
20
20
|
this.accessory = accessory;
|
|
21
21
|
this.NuHeatAPI = NuHeatAPI;
|
|
22
22
|
this.temperatureScale = temperatureScale;
|
|
23
|
+
this.enableThermostatModeControl = enableThermostatModeControl;
|
|
23
24
|
this.accessory
|
|
24
25
|
.getService(homebridge.hap.Service.AccessoryInformation)
|
|
25
26
|
.setCharacteristic(Characteristic.Manufacturer, "NuHeat")
|
|
@@ -31,10 +32,17 @@ class NuHeatThermostat {
|
|
|
31
32
|
setupListeners() {
|
|
32
33
|
const thermostatService = this.accessory.getService(ThermostatService);
|
|
33
34
|
this.log.info("holdLength: " + this.holdLength, this.deviceData.name);
|
|
35
|
+
const targetHeatingCoolingStates = this.enableThermostatModeControl
|
|
36
|
+
? [
|
|
37
|
+
Characteristic.TargetHeatingCoolingState.OFF,
|
|
38
|
+
Characteristic.TargetHeatingCoolingState.HEAT,
|
|
39
|
+
Characteristic.TargetHeatingCoolingState.AUTO,
|
|
40
|
+
]
|
|
41
|
+
: [Characteristic.TargetHeatingCoolingState.HEAT];
|
|
34
42
|
thermostatService
|
|
35
43
|
.getCharacteristic(Characteristic.TargetHeatingCoolingState)
|
|
36
44
|
.setProps({
|
|
37
|
-
validValues:
|
|
45
|
+
validValues: targetHeatingCoolingStates,
|
|
38
46
|
})
|
|
39
47
|
.on("set", this.setTargetHeatingCooling.bind(this));
|
|
40
48
|
thermostatService.getCharacteristic(Characteristic.CurrentTemperature).setProps({
|
|
@@ -50,25 +58,79 @@ class NuHeatThermostat {
|
|
|
50
58
|
this.updateTemperatureDisplayUnits();
|
|
51
59
|
}
|
|
52
60
|
async setTargetHeatingCooling(value, callback) {
|
|
61
|
+
if (this.enableThermostatModeControl) {
|
|
62
|
+
await this.setThermostatModeFromHomeKit(value, callback);
|
|
63
|
+
return;
|
|
64
|
+
}
|
|
53
65
|
if (value !== Characteristic.TargetHeatingCoolingState.OFF) {
|
|
54
66
|
callback(null);
|
|
55
67
|
void this.updateAccessory();
|
|
56
68
|
return;
|
|
57
69
|
}
|
|
58
70
|
this.log.info("NuHeat does not support an off mode. Setting the thermostat to its minimum target temperature instead.", this.deviceData.name);
|
|
59
|
-
const response = await this.NuHeatAPI.setHeatSetpoint(this.deviceData.serialNumber ?? "", this.toNuHeatTemperature(
|
|
71
|
+
const response = await this.NuHeatAPI.setHeatSetpoint(this.deviceData.serialNumber ?? "", this.toNuHeatTemperature(NuHeatModels_1.STANDBY_SETPOINT_C), this.holdLength);
|
|
60
72
|
if (!response) {
|
|
61
73
|
this.log.error("Error setting minimum target temperature for off request", this.deviceData.name);
|
|
62
74
|
callback(new Error("Error: setTargetHeatingCooling"));
|
|
63
75
|
return;
|
|
64
76
|
}
|
|
65
|
-
|
|
77
|
+
// The v1 write returns 204 with no content, so re-read the authoritative
|
|
78
|
+
// state instead of pushing the empty response into HomeKit.
|
|
79
|
+
await this.updateAccessory();
|
|
80
|
+
callback(null);
|
|
81
|
+
}
|
|
82
|
+
/**
|
|
83
|
+
* The v1 update model cannot request standby or an indefinite auto schedule,
|
|
84
|
+
* so mode changes go through the v2 mode endpoints. Those writes return no
|
|
85
|
+
* content, so the authoritative state is re-read through v1 afterwards.
|
|
86
|
+
*/
|
|
87
|
+
async setThermostatModeFromHomeKit(value, callback) {
|
|
88
|
+
const { OFF, HEAT, AUTO } = Characteristic.TargetHeatingCoolingState;
|
|
89
|
+
let mode;
|
|
90
|
+
const options = {};
|
|
91
|
+
if (value === OFF) {
|
|
92
|
+
mode = NuHeatModels_1.HEATING_MODE.OFF;
|
|
93
|
+
options.setPointTemp = this.toNuHeatTemperature(NuHeatModels_1.STANDBY_SETPOINT_C);
|
|
94
|
+
this.log.info("Setting the thermostat to standby (minimum target temperature).", this.deviceData.name);
|
|
95
|
+
}
|
|
96
|
+
else if (value === AUTO) {
|
|
97
|
+
mode = NuHeatModels_1.HEATING_MODE.AUTO;
|
|
98
|
+
this.log.info("Resuming the NuHeat schedule.", this.deviceData.name);
|
|
99
|
+
}
|
|
100
|
+
else if (value === HEAT) {
|
|
101
|
+
// Deliberately omit the setpoint: the v2 mode body's temperature field
|
|
102
|
+
// is optional, and HomeKit sends mode and temperature as separate
|
|
103
|
+
// concurrent writes. Sending a stale setpoint here can clobber the
|
|
104
|
+
// setpoint write that lands right after this one.
|
|
105
|
+
if (this.holdLength >= 1440) {
|
|
106
|
+
mode = NuHeatModels_1.HEATING_MODE.MANUAL;
|
|
107
|
+
}
|
|
108
|
+
else {
|
|
109
|
+
mode = NuHeatModels_1.HEATING_MODE.HOLD;
|
|
110
|
+
if (this.holdLength > 0) {
|
|
111
|
+
options.holdLength = this.holdLength;
|
|
112
|
+
}
|
|
113
|
+
}
|
|
114
|
+
this.log.info("Holding the thermostat target temperature.", this.deviceData.name);
|
|
115
|
+
}
|
|
116
|
+
else {
|
|
117
|
+
this.log.error("Unsupported target heating state " + value, this.deviceData.name);
|
|
118
|
+
callback(new Error("Error: setTargetHeatingCooling"));
|
|
119
|
+
return;
|
|
120
|
+
}
|
|
121
|
+
const response = await this.NuHeatAPI.setThermostatMode(this.deviceData.serialNumber ?? "", mode, options);
|
|
122
|
+
if (!response) {
|
|
123
|
+
this.log.error("Error setting thermostat mode", this.deviceData.name);
|
|
124
|
+
callback(new Error("Error: setTargetHeatingCooling"));
|
|
125
|
+
return;
|
|
126
|
+
}
|
|
127
|
+
await this.updateAccessory();
|
|
66
128
|
callback(null);
|
|
67
129
|
}
|
|
68
130
|
async setTargetTemperature(value, callback) {
|
|
69
131
|
this.log.info("Setting target temperature to " + value + " C", this.deviceData.name);
|
|
70
|
-
if (value <
|
|
71
|
-
value =
|
|
132
|
+
if (value < NuHeatModels_1.STANDBY_SETPOINT_C)
|
|
133
|
+
value = NuHeatModels_1.STANDBY_SETPOINT_C;
|
|
72
134
|
if (value > MAX_TARGET_TEMPERATURE_C)
|
|
73
135
|
value = MAX_TARGET_TEMPERATURE_C;
|
|
74
136
|
const heatSetPoint = this.toNuHeatTemperature(value);
|
|
@@ -79,7 +141,9 @@ class NuHeatThermostat {
|
|
|
79
141
|
callback(new Error("Error: setTargetTemperature"));
|
|
80
142
|
}
|
|
81
143
|
else {
|
|
82
|
-
|
|
144
|
+
// The v1 write returns 204 with no content, so re-read the authoritative
|
|
145
|
+
// state instead of pushing the empty response into HomeKit.
|
|
146
|
+
await this.updateAccessory();
|
|
83
147
|
callback(null);
|
|
84
148
|
}
|
|
85
149
|
}
|
|
@@ -93,6 +157,13 @@ class NuHeatThermostat {
|
|
|
93
157
|
}
|
|
94
158
|
}
|
|
95
159
|
updateValues(newValues) {
|
|
160
|
+
// Write calls that return 204 No Content resolve to a literal `true`.
|
|
161
|
+
// That is not thermostat data; pushing it would flash garbage temperatures
|
|
162
|
+
// and blank the cached device data until the next poll.
|
|
163
|
+
if (!newValues || typeof newValues !== "object") {
|
|
164
|
+
this.log.debug("Ignoring a thermostat update without payload data", this.deviceData.name);
|
|
165
|
+
return;
|
|
166
|
+
}
|
|
96
167
|
if (this.isOnline(newValues)) {
|
|
97
168
|
this.updateTemperatureDisplayUnits();
|
|
98
169
|
let currentTemperature = Number(this.toHBTemperature(newValues.currentTemperature ?? 0));
|
|
@@ -102,8 +173,8 @@ class NuHeatThermostat {
|
|
|
102
173
|
.getCharacteristic(Characteristic.CurrentTemperature)
|
|
103
174
|
.updateValue(currentTemperature);
|
|
104
175
|
let setPointTemperature = Number(this.toHBTemperature(newValues.setPointTemp ?? 0));
|
|
105
|
-
if (setPointTemperature <
|
|
106
|
-
setPointTemperature =
|
|
176
|
+
if (setPointTemperature < NuHeatModels_1.STANDBY_SETPOINT_C) {
|
|
177
|
+
setPointTemperature = NuHeatModels_1.STANDBY_SETPOINT_C;
|
|
107
178
|
}
|
|
108
179
|
if (setPointTemperature > MAX_TARGET_TEMPERATURE_C) {
|
|
109
180
|
setPointTemperature = MAX_TARGET_TEMPERATURE_C;
|
|
@@ -139,16 +210,25 @@ class NuHeatThermostat {
|
|
|
139
210
|
return (((temperature * 9) / 5 + 32 - 33) * 56 + 33).toFixed(0);
|
|
140
211
|
}
|
|
141
212
|
toHBTemperature(temperature) {
|
|
142
|
-
return ((
|
|
213
|
+
return (0, NuHeatModels_1.fromNuHeatTemperature)(temperature).toFixed(1);
|
|
143
214
|
}
|
|
144
215
|
toHomeBridgeHeatingCoolingState(newValues) {
|
|
145
|
-
if (!this.
|
|
146
|
-
|
|
216
|
+
if (!this.enableThermostatModeControl) {
|
|
217
|
+
if (!this.isOnline(newValues)) {
|
|
218
|
+
return Characteristic.TargetHeatingCoolingState.OFF;
|
|
219
|
+
}
|
|
220
|
+
// The v1 read model cannot distinguish standby from a scheduled run, and
|
|
221
|
+
// the characteristic only advertises heat, so heat is the only safe
|
|
222
|
+
// report.
|
|
223
|
+
return Characteristic.TargetHeatingCoolingState.HEAT;
|
|
147
224
|
}
|
|
148
|
-
switch (
|
|
149
|
-
case NuHeatModels_1.
|
|
150
|
-
|
|
151
|
-
|
|
225
|
+
switch ((0, NuHeatModels_1.deriveHeatingMode)(newValues)) {
|
|
226
|
+
case NuHeatModels_1.HEATING_MODE.OFF:
|
|
227
|
+
return Characteristic.TargetHeatingCoolingState.OFF;
|
|
228
|
+
case NuHeatModels_1.HEATING_MODE.AUTO:
|
|
229
|
+
return Characteristic.TargetHeatingCoolingState.AUTO;
|
|
230
|
+
case NuHeatModels_1.HEATING_MODE.MANUAL:
|
|
231
|
+
case NuHeatModels_1.HEATING_MODE.HOLD:
|
|
152
232
|
default:
|
|
153
233
|
return Characteristic.TargetHeatingCoolingState.HEAT;
|
|
154
234
|
}
|