homebridge-melcloud-control 3.8.0-beta.33 → 3.8.0-beta.34
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/package.json +1 -1
- package/src/deviceatw.js +3 -3
package/package.json
CHANGED
|
@@ -1,7 +1,7 @@
|
|
|
1
1
|
{
|
|
2
2
|
"displayName": "MELCloud Control",
|
|
3
3
|
"name": "homebridge-melcloud-control",
|
|
4
|
-
"version": "3.8.0-beta.
|
|
4
|
+
"version": "3.8.0-beta.34",
|
|
5
5
|
"description": "Homebridge plugin to control Mitsubishi Air Conditioner, Heat Pump and Energy Recovery Ventilation.",
|
|
6
6
|
"license": "MIT",
|
|
7
7
|
"author": "grzegorz914",
|
package/src/deviceatw.js
CHANGED
|
@@ -1827,8 +1827,8 @@ class DeviceAtw extends EventEmitter {
|
|
|
1827
1827
|
switch (i) {
|
|
1828
1828
|
case caseHeatPumpSensor: //Heat Pump - HEAT, COOL, OFF
|
|
1829
1829
|
const info = outdoorTemperature !== null ? this.emit('message', `${heatPumpName}, Outdoor temperature: ${outdoorTemperature}${this.accessory.temperatureUnit}`) : false;
|
|
1830
|
-
const info0 = flowTemperatureHeatPump !== null ? this.emit('message', `${heatPumpName}, Flow temperature: ${
|
|
1831
|
-
const info1 = returnTemperatureHeatPump !== null ? this.emit('message', `${heatPumpName}, Return temperature: ${
|
|
1830
|
+
const info0 = flowTemperatureHeatPump !== null ? this.emit('message', `${heatPumpName}, Flow temperature: ${flowTemperatureHeatPump}${this.accessory.temperatureUnit}`) : false;
|
|
1831
|
+
const info1 = returnTemperatureHeatPump !== null ? this.emit('message', `${heatPumpName}, Return temperature: ${returnTemperatureHeatPump}${this.accessory.temperatureUnit}`) : false;
|
|
1832
1832
|
break;
|
|
1833
1833
|
case caseZone1Sensor: //Zone 1 - HEAT THERMOSTAT, HEAT FLOW, HEAT CURVE, COOL THERMOSTAT, COOL FLOW, FLOOR DRY UP
|
|
1834
1834
|
const info2 = roomTemperatureZone1 !== null ? this.emit('message', `${zone1Name}, Room temperature: ${roomTemperatureZone1}${this.accessory.temperatureUnit}`) : false;
|
|
@@ -1843,7 +1843,7 @@ class DeviceAtw extends EventEmitter {
|
|
|
1843
1843
|
case caseZone2Sensor: //Zone 2 - HEAT THERMOSTAT, HEAT FLOW, HEAT CURVE, COOL THERMOSTAT, COOL FLOW, FLOOR DRY UP
|
|
1844
1844
|
const info8 = roomTemperatureZone2 !== null ? this.emit('message', `${zone2Name}, Room temperature: ${roomTemperatureZone2}${this.accessory.temperatureUnit}`) : false;
|
|
1845
1845
|
const info9 = flowTemperatureZone2 !== null ? this.emit('message', `${zone2Name}, Flow temperature: ${flowTemperatureZone2}${this.accessory.temperatureUnit}`) : false;
|
|
1846
|
-
const info10 =
|
|
1846
|
+
const info10 = returnTemperatureZone2 !== null ? this.emit('message', `${zone2Name}, Return temperature: ${returnTemperatureZone1}${this.accessory.temperatureUnit}`) : false;
|
|
1847
1847
|
break;
|
|
1848
1848
|
};
|
|
1849
1849
|
};
|