This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/CHANGELOG.md ADDED
@@ -0,0 +1,124 @@
1
+ # Changelog
2
+
3
+ All notable changes of hm-simulator. The release workflow takes each version's section from here for the
4
+ GitHub release notes.
5
+
6
+ ## 1.3.0
7
+
8
+ - The calls Homematic Manager makes, measured on rfd and hmipserver of firmware 3.89.11:
9
+ `getKeyMismatchDevice` with the scenario call `scriptKeyMismatch` (a device that holds another
10
+ system's key: heard at the next install mode, paired once `setTempKey` offers its key) and rfd's
11
+ `addDevice(serial)`; `suppressServiceMessages` and `getSuppressedServiceMessages` on hmipserver
12
+ (a suppressed message is left out of `getServiceMessages` and reports the value that raises
13
+ none); `getMetadata`, `setMetadata` and rfd's `getAllMetadata`, seeded with the new `metadata`
14
+ option; `listReplaceableDevices`; `getVersion` (`interfaces.<iface>.version`); `getLGWStatus`
15
+ (only with `interfaces.<iface>.lgwStatus` - rfd 3.89.11 does not know it); `setInterfaceClock`
16
+ (recorded in `sim.interfaceClocks`).
17
+ - TypeScript declarations: `sim.d.ts` (the `types` of the package), `sim.d.mts` for `sim.mjs` and
18
+ `lib/faults.d.ts`, covering the options, the scenario API, the introspection calls and the
19
+ description types. `npm test` type-checks them against a file that uses every export
20
+ (`test/types/`), and a test fails when an option or scenario call is missing from them.
21
+ - `interfaces.<iface>.getServiceMessagesFault: true` answers `getServiceMessages` with
22
+ `Invalid XML-RPC message`, as VirtualDevices, CUxD and hmipserver were seen to on 3.89.x.
23
+
24
+ ## 1.2.0
25
+
26
+ - The README is rewritten for the test author (quick start, connecting a client, the scenario API
27
+ grouped, recipes, the fixtures, what is measured and what is the simulator's model), and the
28
+ changelog moved into this file.
29
+ - `data/fixtures/lab-2026-09.json`: the devices of four test systems with the paramset
30
+ descriptions of their exact firmware, their direct links and radio modules - the CCU centrals,
31
+ RPI-RF-MOD, HmIP-RFUSB, HmIP-HAP, HmIP-BBL, HMIP-WRC2, HmIP-PDT, HmIPW-DRAP/-DRI16/-DRS8,
32
+ HM-CC-TC, HM-Sec-SC, HM-LC-Sw1-Pl-2 - anonymised. `tools/dump-ccu.js` makes such a fixture from
33
+ any CCU (read only, anonymised unless told otherwise). A device file given to `--devices` brings
34
+ its `links` and `bidcosInterfaces` along.
35
+ - The calls openccu-lite's daemon makes: `logLevel` (rfd and hs485d answer the level, 5 until set;
36
+ hmipserver an empty string), `changeKey` (rfd, hmipserver; recorded in `sim.keyChanges`) and
37
+ `refreshDeployedDeviceFirmwareList` (rfd, hmipserver; recorded in
38
+ `sim.firmwareListRefreshes`), with the interfaces measured on a CCU with firmware 3.89.x.
39
+ - `init` keeps the path of an XML-RPC callback url (`http://host:port/cb/BidCos-RF`; the path used
40
+ to end up in the port), takes `https://`, and identifies a registration by its url exactly, scheme
41
+ included, as the interface processes do - an `init(url, '')` with another scheme no longer removes
42
+ it. A url that is none is a fault.
43
+ - An XML-RPC request declared ISO-8859-1 is read as ISO-8859-1 instead of UTF-8.
44
+ - Device and radio health: `setReachable` (UNREACH, and STICKY_UNREACH on BidCos until a client
45
+ clears it; `unreachWrites: 'fault'` answers writes with notReachable), `setLowBattery`,
46
+ `setDutyCycle` and `setCarrierSense` (in `listBidcosInterfaces` and, on hmip, as the radio
47
+ module's `DUTY_CYCLE_LEVEL`/`CARRIER_SENSE_LEVEL`), `offerFirmware` with the update states
48
+ `updateFirmware`/`installFirmware` then walk through, and `schedule` for a timeline of scenario
49
+ calls.
50
+ - Interface processes that misbehave: `stopInterface`, `startInterface` and `restartInterface`
51
+ (forgetting the registered clients, or calling them back as rfd does after a restart),
52
+ `interfaces.<iface>.startDelay`, `pong` and `pingDelay`, `injectFault` (delay, hang, fault,
53
+ closed connection, for the next calls of a method) and `clearFaults`, and
54
+ `listenerModel: 'measured'`: what hmipserver and rfd do with a callback server that hangs
55
+ (hmipserver holds every client's events back, rfd stops answering). `getCallbackLog()` records
56
+ every call to a client with its timing, `fireEvents()` sends bursts as `system.multicall` batches.
57
+ - The command line is usable out of process: every port may be `0`, `--ports-json <file|->`
58
+ reports the ports once every server listens, `--config` and `--devices` load options and device
59
+ files, `--wired-port`, `--tls` with `--tls-cert-out`, `--auth`, `--behavior-path`,
60
+ `--no-behaviors`, and `--control-port` serves the scenario API over HTTP on the loopback. A taken
61
+ port exits 1 with the address in the message. `behaviorPath: false` starts no behaviour scripts.
62
+ - An ENUM whose description gives `DEFAULT` as the index (1088 of the 5624 ENUMs in the bundled
63
+ descriptions) started at `-1` instead of that index, so a thermostat's `FAULT_REPORTING` was a
64
+ service message from the start.
65
+ - rfd and BidCos-Wired answer BIN-RPC and XML-RPC on the same port, as on a CCU, so a client
66
+ that talks XML-RPC to rfd can be tested too; the callbacks follow the URL a client registered
67
+ with, whichever protocol it registered over. With `tls` the XML-RPC half is HTTPS, BIN-RPC stays
68
+ plain. `interfaces.<iface>.protocols` narrows a port to one of them.
69
+ - A device whose firmware has no paramset description uses the description of the nearest
70
+ firmware of the same type and `VERSION` instead of answering `-2 Invalid device` for every
71
+ channel `listDevices` reports; the bundled CCU virtual remote (`HM-RCV-50` 2.27.8,
72
+ `BidCoS-RF:1..50`) works again. `paramsetFallback: false` switches it off,
73
+ `sim.getMissingParamsetDescriptions()` lists what is not matched exactly (reported in #1 by
74
+ @Hypnos3, cause found by @foxriver76).
75
+
76
+ ## 1.1.0
77
+
78
+ - `setTempKey` on the BidCos interfaces: the passphrase a device is taught in with, applied to
79
+ the pairings that follow; `sim.getTempKey(iface)` reads back what was set, an empty string
80
+ clears it. No cryptography. hmipserver has no such method, so it faults with unknown-method
81
+ there (Homematic Manager issue #20).
82
+ - Smoke detector teams on the BidCos interfaces: `listTeams` and `setTeam`. A channel with a
83
+ `TEAM_TAG` is in the team its `TEAM` names, a pseudo device `*<serial>` whose team channel lists
84
+ the members in `TEAM_CHANNELS`; `setTeam(channel, team)` moves it and deletes a team nobody is
85
+ left in, `setTeam(channel, '')` puts it back into a team of its own, created like the one it
86
+ left (`newDevices`, `deleteDevices`, `updateDevice` to the logic layers). The shape is rfd's
87
+ as Homematic Manager task 58 read it from a CCU3; when rfd deletes and creates the team devices
88
+ is the simulator's model, not a measurement.
89
+
90
+ ## 1.0.0
91
+
92
+ - Node >= 20.19, `binrpc` ^4.2, `homematic-xmlrpc` ^2.0; `express`, `body-parser`, `request`,
93
+ `async` and `yalm` removed. The ReGa mock runs on `node:http`, the CLI logs through `console`.
94
+ - Paramset state per device and channel for MASTER, VALUES, SERVICE and the link paramsets, with
95
+ type, range, `VALUE_LIST` and `OPERATIONS` checks on every write.
96
+ - `CONFIG_PENDING` semantics, configurable per interface: `'hmip'` and `'bidcos'` are what the
97
+ two interface processes of a CCU on firmware 3.89.8 were measured to do (Homematic Manager task
98
+ 6, 2026-09-05), `'strict'` and `'pending'` are the two hypotheses that measurement replaced.
99
+ `getPoisonedChannels()` for the channel an unknown parameter destroyed.
100
+ - Fault codes and strings measured on the same firmware, hmipserver's as the default table and
101
+ rfd's as `BIDCOS_FAULTS`.
102
+ - `data/fixtures/lab-devices.json`: an anonymised real `listDevices` of two CCUs, and the channel
103
+ layouts in `tools/device-layouts.json` corrected from it.
104
+ - Links: `getLinks`, `getLinkPeers`, `getLinkInfo`, `setLinkInfo`, `addLink`, `removeLink`,
105
+ `activateLinkParamset`, and link paramsets addressed by the peer's address.
106
+ - Interface and service methods: `rssiInfo`, `listBidcosInterfaces`, `setBidcosInterface`,
107
+ `getServiceMessages`, `setInstallMode`/`getInstallMode` with scripted `newDevices`,
108
+ `deleteDevice`, `replaceDevice`, `reportValueUsage`, `updateFirmware`, `installFirmware`,
109
+ `clearConfigCache`, `restoreConfigToDevice`, `determineParameter`, `getDeviceDescription`,
110
+ `getValue`, `system.methodHelp`, `system.multicall`.
111
+ - Fault responses on both transports, with an overridable fault table.
112
+ - VirtualDevices and CUxD servers, BidCos-Wired, optional TLS with a generated certificate and
113
+ optional HTTP basic auth.
114
+ - ReGa mock with `getChannels`, `getValues`, rename/program scripts and a script log.
115
+ - Scenario API: `addDevice`, `removeDevice`, `fireEvent`, `setServiceMessage`, `scriptNewDevices`,
116
+ `dropConnection`, `getWriteLog`, `getConfigPending`.
117
+ - `whenReady()`, port `0` support and `sim.ports`.
118
+ - Fixture generator `tools/fixtures-from-paramsets.js` and generated real device fixtures.
119
+ - ESLint 9 + Prettier, `node --test`, GitHub Actions on Node 20/22/24.
120
+
121
+ ## 0.1.1 and earlier
122
+
123
+ `init`, `ping`, `system.listMethods`, `getParamsetDescription`, `listDevices`, `setValue`, events
124
+ through behaviour scripts, ReGa mock.