ednl-liftstatus-web-components 1.18.0 → 1.18.2

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -63945,6 +63945,10 @@ const statusCodes = {
63945
63945
  "arkel-35": {
63946
63946
  description: "Safety-chain(120) interrupted during travel",
63947
63947
  level: "impact"
63948
+ },
63949
+ "arkel-36": {
63950
+ description: "Absolute encoder fault (Elgo LIMAX)",
63951
+ level: "impact"
63948
63952
  },
63949
63953
  "arkel-37": {
63950
63954
  description: "140 interrupted during travel",
@@ -63977,6 +63981,10 @@ const statusCodes = {
63977
63981
  "arkel-44": {
63978
63982
  description: "818 signal was not ON when it should",
63979
63983
  level: "impact"
63984
+ },
63985
+ "arkel-45": {
63986
+ description: "Door limit-switch fault",
63987
+ level: "impact"
63980
63988
  },
63981
63989
  "arkel-47": {
63982
63990
  description: "Brake resistor overheated",
@@ -64045,6 +64053,14 @@ const statusCodes = {
64045
64053
  "arkel-63": {
64046
64054
  description: "Watchdog timeout",
64047
64055
  level: "impact"
64056
+ },
64057
+ "arkel-65": {
64058
+ description: "DFC communication error",
64059
+ level: "impact"
64060
+ },
64061
+ "arkel-66": {
64062
+ description: "Door contacts or DFC board error",
64063
+ level: "impact"
64048
64064
  },
64049
64065
  "arkel-71": {
64050
64066
  description: "Licence key (dongle) not found.",
@@ -64057,6 +64073,18 @@ const statusCodes = {
64057
64073
  "arkel-73": {
64058
64074
  description: "Detected entry inside shaft",
64059
64075
  level: "impact"
64076
+ },
64077
+ "arkel-74": {
64078
+ description: "Encoder offset angels couldn’t founded",
64079
+ level: "impact"
64080
+ },
64081
+ "arkel-75": {
64082
+ description: "CML feedback error",
64083
+ level: "impact"
64084
+ },
64085
+ "arkel-76": {
64086
+ description: "Shaft protection reset key is active",
64087
+ level: "impact"
64060
64088
  },
64061
64089
  "arkel-79": {
64062
64090
  description: "Current was over motor limit",
@@ -64109,6 +64137,14 @@ const statusCodes = {
64109
64137
  "arkel-91": {
64110
64138
  description: "Shaft too high",
64111
64139
  level: "impact"
64140
+ },
64141
+ "arkel-92": {
64142
+ description: "Position tracking error",
64143
+ level: "impact"
64144
+ },
64145
+ "arkel-93": {
64146
+ description: "Maintenance time exceeded",
64147
+ level: "impact"
64112
64148
  },
64113
64149
  "arkel-94": {
64114
64150
  description: "Carlight fuse is blown.",
@@ -64121,6 +64157,30 @@ const statusCodes = {
64121
64157
  "arkel-96": {
64122
64158
  description: "UPS failed on test.",
64123
64159
  level: "impact"
64160
+ },
64161
+ "arkel-97": {
64162
+ description: "Direction change limit reached",
64163
+ level: "impact"
64164
+ },
64165
+ "arkel-98": {
64166
+ description: "One of critical devices is offline",
64167
+ level: "impact"
64168
+ },
64169
+ "arkel-99": {
64170
+ description: "Rope slip correction error",
64171
+ level: "impact"
64172
+ },
64173
+ "arkel-100": {
64174
+ description: "External Perm. Error-1 (Except Recall)",
64175
+ level: "impact"
64176
+ },
64177
+ "arkel-101": {
64178
+ description: "Insp./Recall terminal connection wrong",
64179
+ level: "impact"
64180
+ },
64181
+ "arkel-102": {
64182
+ description: "EN signal not cut-off",
64183
+ level: "impact"
64124
64184
  },
64125
64185
  "arkel-500_1": {
64126
64186
  description: "Power failure",
@@ -64436,7 +64496,7 @@ const statusCodes = {
64436
64496
  },
64437
64497
  "bohnke-27-01-05": {
64438
64498
  description: "Electrical hand winding control is activated",
64439
- level: "non-impact"
64499
+ level: "impact"
64440
64500
  },
64441
64501
  "bohnke-27-01-06": {
64442
64502
  description: "Attendant control activated",
@@ -64508,7 +64568,7 @@ const statusCodes = {
64508
64568
  },
64509
64569
  "bohnke-27-03-07": {
64510
64570
  description: "lift is \"out of order\"",
64511
- level: "non-impact"
64571
+ level: "impact"
64512
64572
  },
64513
64573
  "bohnke-27-04-00": {
64514
64574
  description: "\"no load\" is activated",
@@ -64536,7 +64596,7 @@ const statusCodes = {
64536
64596
  },
64537
64597
  "bohnke-27-04-06": {
64538
64598
  description: "encoder: system ok!",
64539
- level: "non-impact"
64599
+ level: "informational"
64540
64600
  },
64541
64601
  "bohnke-27-04-07": {
64542
64602
  description: "encoder: learning trip required",
@@ -64604,7 +64664,7 @@ const statusCodes = {
64604
64664
  },
64605
64665
  "bohnke-27-06-07": {
64606
64666
  description: "lift is in parking position",
64607
- level: "non-impact"
64667
+ level: "informational"
64608
64668
  },
64609
64669
  "bohnke-27-07-00": {
64610
64670
  description: "...waiting for car call",
@@ -64720,7 +64780,7 @@ const statusCodes = {
64720
64780
  },
64721
64781
  "bohnke-27-10-04": {
64722
64782
  description: "maintenance: \"electrical hand winding control\" active",
64723
- level: "non-impact"
64783
+ level: "informational"
64724
64784
  },
64725
64785
  "bohnke-27-10-05": {
64726
64786
  description: "waiting for call/no-load (term.86=1)",
@@ -66940,7 +67000,7 @@ const statusCodes = {
66940
67000
  },
66941
67001
  "bohnke-eis-28-05-07": {
66942
67002
  description: "generic malfunction information",
66943
- level: "impact"
67003
+ level: "non-impact"
66944
67004
  },
66945
67005
  "bohnke-eis-28-06-00": {
66946
67006
  description: "",
@@ -69276,7 +69336,7 @@ const statusCodes = {
69276
69336
  },
69277
69337
  "bohnke-eis-1F31": {
69278
69338
  description: "EEO outside limits active",
69279
- level: "non-impact"
69339
+ level: "informational"
69280
69340
  },
69281
69341
  "bohnke-eis-1F32": {
69282
69342
  description: "Random calls active (menu)",
@@ -76924,7 +76984,7 @@ const statusCodes = {
76924
76984
  },
76925
76985
  "kollmorgen-lan-IDS_INSPEKTION": {
76926
76986
  description: "Inspection operation",
76927
- level: "non-impact"
76987
+ level: "impact"
76928
76988
  },
76929
76989
  "kollmorgen-lan-IDS_RUECKHOLEN": {
76930
76990
  description: "Emergency electrical operation",