dragonfly-schema 2.105.1 → 2.201.1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/index.cjs +60 -0
- package/dist/index.cjs.map +1 -1
- package/dist/index.d.cts +12 -0
- package/dist/index.d.ts +12 -0
- package/dist/index.js +88 -28
- package/dist/index.js.map +1 -1
- package/package.json +1 -1
package/dist/index.cjs
CHANGED
|
@@ -2169,6 +2169,12 @@ var _Room2DEnergyPropertiesAbridged = class _Room2DEnergyPropertiesAbridged exte
|
|
|
2169
2169
|
this.programType = obj.programType;
|
|
2170
2170
|
this.hvac = obj.hvac;
|
|
2171
2171
|
this.shw = obj.shw;
|
|
2172
|
+
this.personCount = obj.personCount;
|
|
2173
|
+
this.lightingWatts = obj.lightingWatts;
|
|
2174
|
+
this.electricEquipmentWatts = obj.electricEquipmentWatts;
|
|
2175
|
+
this.gasEquipmentWatts = obj.gasEquipmentWatts;
|
|
2176
|
+
this.hotWaterFlow = obj.hotWaterFlow;
|
|
2177
|
+
this.infiltrationAch = obj.infiltrationAch;
|
|
2172
2178
|
this.processLoads = obj.processLoads;
|
|
2173
2179
|
this.daylightingControl = obj.daylightingControl;
|
|
2174
2180
|
this.windowVentControl = obj.windowVentControl;
|
|
@@ -2196,6 +2202,12 @@ var _Room2DEnergyPropertiesAbridged = class _Room2DEnergyPropertiesAbridged exte
|
|
|
2196
2202
|
data["program_type"] = this.programType;
|
|
2197
2203
|
data["hvac"] = this.hvac;
|
|
2198
2204
|
data["shw"] = this.shw;
|
|
2205
|
+
data["person_count"] = this.personCount;
|
|
2206
|
+
data["lighting_watts"] = this.lightingWatts;
|
|
2207
|
+
data["electric_equipment_watts"] = this.electricEquipmentWatts;
|
|
2208
|
+
data["gas_equipment_watts"] = this.gasEquipmentWatts;
|
|
2209
|
+
data["hot_water_flow"] = this.hotWaterFlow;
|
|
2210
|
+
data["infiltration_ach"] = this.infiltrationAch;
|
|
2199
2211
|
data["process_loads"] = this.processLoads;
|
|
2200
2212
|
data["daylighting_control"] = this.daylightingControl;
|
|
2201
2213
|
data["window_vent_control"] = this.windowVentControl;
|
|
@@ -2256,6 +2268,54 @@ __decorateClass([
|
|
|
2256
2268
|
(0, import_class_validator31.MaxLength)(100),
|
|
2257
2269
|
(0, import_class_transformer26.Expose)({ name: "shw" })
|
|
2258
2270
|
], _Room2DEnergyPropertiesAbridged.prototype, "shw", 2);
|
|
2271
|
+
/** Number for the total number of people in the room or an Unassigned object to indicate that people are assigned via the program_type. */
|
|
2272
|
+
__decorateClass([
|
|
2273
|
+
(0, import_class_transformer26.Type)(() => Number),
|
|
2274
|
+
(0, import_class_validator31.IsNumber)(),
|
|
2275
|
+
(0, import_class_validator31.IsOptional)(),
|
|
2276
|
+
(0, import_class_validator31.Min)(0),
|
|
2277
|
+
(0, import_class_transformer26.Expose)({ name: "person_count" })
|
|
2278
|
+
], _Room2DEnergyPropertiesAbridged.prototype, "personCount", 2);
|
|
2279
|
+
/** Number for the total wattage of lighting in the room or an Unassigned object to indicate that lighting is assigned via the program_type. */
|
|
2280
|
+
__decorateClass([
|
|
2281
|
+
(0, import_class_transformer26.Type)(() => Number),
|
|
2282
|
+
(0, import_class_validator31.IsNumber)(),
|
|
2283
|
+
(0, import_class_validator31.IsOptional)(),
|
|
2284
|
+
(0, import_class_validator31.Min)(0),
|
|
2285
|
+
(0, import_class_transformer26.Expose)({ name: "lighting_watts" })
|
|
2286
|
+
], _Room2DEnergyPropertiesAbridged.prototype, "lightingWatts", 2);
|
|
2287
|
+
/** Number for the total wattage of electric equipment in the room or an Unassigned object to indicate that electric equipment is assigned via the program_type. */
|
|
2288
|
+
__decorateClass([
|
|
2289
|
+
(0, import_class_transformer26.Type)(() => Number),
|
|
2290
|
+
(0, import_class_validator31.IsNumber)(),
|
|
2291
|
+
(0, import_class_validator31.IsOptional)(),
|
|
2292
|
+
(0, import_class_validator31.Min)(0),
|
|
2293
|
+
(0, import_class_transformer26.Expose)({ name: "electric_equipment_watts" })
|
|
2294
|
+
], _Room2DEnergyPropertiesAbridged.prototype, "electricEquipmentWatts", 2);
|
|
2295
|
+
/** Number for the total wattage of gas equipment in the room or an Unassigned object to indicate that gas equipment is assigned via the program_type. */
|
|
2296
|
+
__decorateClass([
|
|
2297
|
+
(0, import_class_transformer26.Type)(() => Number),
|
|
2298
|
+
(0, import_class_validator31.IsNumber)(),
|
|
2299
|
+
(0, import_class_validator31.IsOptional)(),
|
|
2300
|
+
(0, import_class_validator31.Min)(0),
|
|
2301
|
+
(0, import_class_transformer26.Expose)({ name: "gas_equipment_watts" })
|
|
2302
|
+
], _Room2DEnergyPropertiesAbridged.prototype, "gasEquipmentWatts", 2);
|
|
2303
|
+
/** Number for the total flow of hot water in the room or an Unassigned object to indicate that service hot water is assigned via the program_type. */
|
|
2304
|
+
__decorateClass([
|
|
2305
|
+
(0, import_class_transformer26.Type)(() => Number),
|
|
2306
|
+
(0, import_class_validator31.IsNumber)(),
|
|
2307
|
+
(0, import_class_validator31.IsOptional)(),
|
|
2308
|
+
(0, import_class_validator31.Min)(0),
|
|
2309
|
+
(0, import_class_transformer26.Expose)({ name: "hot_water_flow" })
|
|
2310
|
+
], _Room2DEnergyPropertiesAbridged.prototype, "hotWaterFlow", 2);
|
|
2311
|
+
/** Number for the infiltration of the room in air changes per hour or an Unassigned object to indicate that infiltration is assigned via the program_type. */
|
|
2312
|
+
__decorateClass([
|
|
2313
|
+
(0, import_class_transformer26.Type)(() => Number),
|
|
2314
|
+
(0, import_class_validator31.IsNumber)(),
|
|
2315
|
+
(0, import_class_validator31.IsOptional)(),
|
|
2316
|
+
(0, import_class_validator31.Min)(0),
|
|
2317
|
+
(0, import_class_transformer26.Expose)({ name: "infiltration_ach" })
|
|
2318
|
+
], _Room2DEnergyPropertiesAbridged.prototype, "infiltrationAch", 2);
|
|
2259
2319
|
/** An optional list of Process objects for process loads within the room. These can represent wood burning fireplaces, kilns, manufacturing equipment, and various industrial processes. They can also be used to represent certain pieces of equipment to be separated from the other end uses, such as MRI machines, theatrical lighting, and elevators. */
|
|
2260
2320
|
__decorateClass([
|
|
2261
2321
|
(0, import_class_validator31.IsArray)(),
|