ato-water-lib 0.0.99 → 0.0.101
Sign up to get free protection for your applications and to get access to all the features.
- package/esm2020/lib/constants/components-group-const.mjs +37 -30
- package/fesm2015/ato-water-lib.mjs +33 -33
- package/fesm2015/ato-water-lib.mjs.map +1 -1
- package/fesm2020/ato-water-lib.mjs +36 -29
- package/fesm2020/ato-water-lib.mjs.map +1 -1
- package/lib/constants/components-group-const.d.ts +8 -43
- package/package.json +1 -1
@@ -7089,12 +7089,12 @@ var ENUM_ASSET_PARAMETERS;
|
|
7089
7089
|
ENUM_ASSET_PARAMETERS["VM_APPROACH"] = "VMApproach";
|
7090
7090
|
ENUM_ASSET_PARAMETERS["VM_FAN_SPEED"] = "Fan Speed";
|
7091
7091
|
ENUM_ASSET_PARAMETERS["VM_RECIRCULATION_RATE"] = "Recirculation rate";
|
7092
|
-
// Cooling Tower -- Performance -- Data
|
7093
|
-
ENUM_ASSET_PARAMETERS["
|
7094
|
-
ENUM_ASSET_PARAMETERS["
|
7095
|
-
ENUM_ASSET_PARAMETERS["
|
7096
|
-
ENUM_ASSET_PARAMETERS["
|
7097
|
-
ENUM_ASSET_PARAMETERS["
|
7092
|
+
// Cooling Tower -- Performance -- Data Analysis
|
7093
|
+
ENUM_ASSET_PARAMETERS["DATA_ANALYSIS_RETURN_TEMPERATURE"] = "Return Temperature";
|
7094
|
+
ENUM_ASSET_PARAMETERS["DATA_ANALYSIS_SUPPLY_TEMPERATURE"] = "DA Supply Temperature";
|
7095
|
+
ENUM_ASSET_PARAMETERS["DATA_ANALYSIS_WET_BULB_TEMPERATURE"] = "DA Wet Bulb Temperature";
|
7096
|
+
ENUM_ASSET_PARAMETERS["DATA_ANALYSIS_RANGE"] = "DARange";
|
7097
|
+
ENUM_ASSET_PARAMETERS["DATA_ANALYSIS_APPROACH"] = "DAApproach";
|
7098
7098
|
// Cooling Tower -- Performance -- Efficiency and Performance
|
7099
7099
|
ENUM_ASSET_PARAMETERS["EFFICIENCY_DAILY_AVERAGE"] = "Efficiency Daily Average";
|
7100
7100
|
ENUM_ASSET_PARAMETERS["EFFICIENCY_ADJUSTED_DAILY_AVERAGE"] = "Efficiency Adjusted Daily Average";
|
@@ -7187,7 +7187,7 @@ var WATER_SYSTEMS_NAME;
|
|
7187
7187
|
WATER_SYSTEMS_NAME["RO_CONCENTRATE__CHEMISTRY"] = "Concentrate Chemistry";
|
7188
7188
|
// For Cooling Tower - Performance
|
7189
7189
|
WATER_SYSTEMS_NAME["VISUAL_MANAGEMENT"] = "Visual Management";
|
7190
|
-
WATER_SYSTEMS_NAME["
|
7190
|
+
WATER_SYSTEMS_NAME["DATA_ANALYSIS"] = "Data Analysis";
|
7191
7191
|
WATER_SYSTEMS_NAME["EFFICIENCY_AND_PERFORMANCE"] = "Efficiency and Performance";
|
7192
7192
|
WATER_SYSTEMS_NAME["WATER_AND_ENERGY_CONSUMPTION"] = "Water & Energy Consumption";
|
7193
7193
|
WATER_SYSTEMS_NAME["CHEMICALS_CONSUMPTION"] = "Chemicals consumption";
|
@@ -7543,7 +7543,7 @@ const DATA_ASSET_PARAMETER_FIELDS = {
|
|
7543
7543
|
},
|
7544
7544
|
// Cooling Tower -- Performance -- Visual Management
|
7545
7545
|
[ENUM_ASSET_PARAMETERS.VM_SUPPLY_TEMPERATURE]: {
|
7546
|
-
name: ENUM_ASSET_PARAMETERS.
|
7546
|
+
name: ENUM_ASSET_PARAMETERS.COMMON_SUPPLY_TEMPERATURE,
|
7547
7547
|
key: ENUM_ASSET_PARAMETERS.VM_SUPPLY_TEMPERATURE,
|
7548
7548
|
},
|
7549
7549
|
[ENUM_ASSET_PARAMETERS.VM_WET_BULB_TEMPERATURE]: {
|
@@ -7566,26 +7566,26 @@ const DATA_ASSET_PARAMETER_FIELDS = {
|
|
7566
7566
|
name: ENUM_ASSET_PARAMETERS.VM_RECIRCULATION_RATE,
|
7567
7567
|
key: ENUM_ASSET_PARAMETERS.VM_RECIRCULATION_RATE,
|
7568
7568
|
},
|
7569
|
-
// Cooling Tower -- Performance -- Data
|
7570
|
-
[ENUM_ASSET_PARAMETERS.
|
7569
|
+
// Cooling Tower -- Performance -- Data Analysis
|
7570
|
+
[ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_RETURN_TEMPERATURE]: {
|
7571
7571
|
name: ENUM_ASSET_PARAMETERS.COMMON_RETURN_TEMPERATURE,
|
7572
|
-
key: ENUM_ASSET_PARAMETERS.
|
7572
|
+
key: ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_RETURN_TEMPERATURE,
|
7573
7573
|
},
|
7574
|
-
[ENUM_ASSET_PARAMETERS.
|
7574
|
+
[ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_SUPPLY_TEMPERATURE]: {
|
7575
7575
|
name: ENUM_ASSET_PARAMETERS.COMMON_SUPPLY_TEMPERATURE,
|
7576
|
-
key: ENUM_ASSET_PARAMETERS.
|
7576
|
+
key: ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_SUPPLY_TEMPERATURE,
|
7577
7577
|
},
|
7578
|
-
[ENUM_ASSET_PARAMETERS.
|
7578
|
+
[ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_WET_BULB_TEMPERATURE]: {
|
7579
7579
|
name: ENUM_ASSET_PARAMETERS.COMMON_WET_BULB_TEMPERATURE,
|
7580
|
-
key: ENUM_ASSET_PARAMETERS.
|
7580
|
+
key: ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_WET_BULB_TEMPERATURE,
|
7581
7581
|
},
|
7582
|
-
[ENUM_ASSET_PARAMETERS.
|
7582
|
+
[ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_RANGE]: {
|
7583
7583
|
name: ENUM_ASSET_PARAMETERS.COMMON_RANGE,
|
7584
|
-
key: ENUM_ASSET_PARAMETERS.
|
7584
|
+
key: ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_RANGE,
|
7585
7585
|
},
|
7586
|
-
[ENUM_ASSET_PARAMETERS.
|
7586
|
+
[ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_APPROACH]: {
|
7587
7587
|
name: ENUM_ASSET_PARAMETERS.COMMON_APPROACH,
|
7588
|
-
key: ENUM_ASSET_PARAMETERS.
|
7588
|
+
key: ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_APPROACH,
|
7589
7589
|
},
|
7590
7590
|
// Cooling Tower -- Performance -- Efficiency and Performance
|
7591
7591
|
[ENUM_ASSET_PARAMETERS.EFFICIENCY_DAILY_AVERAGE]: {
|
@@ -7946,8 +7946,8 @@ const DATA_WATER_SYSTEMS = {
|
|
7946
7946
|
title: WATER_SYSTEMS_NAME.VISUAL_MANAGEMENT,
|
7947
7947
|
...STYLE_TABLE_PARAM.FLAMINGO,
|
7948
7948
|
},
|
7949
|
-
[WATER_SYSTEMS_NAME.
|
7950
|
-
title: WATER_SYSTEMS_NAME.
|
7949
|
+
[WATER_SYSTEMS_NAME.DATA_ANALYSIS]: {
|
7950
|
+
title: WATER_SYSTEMS_NAME.DATA_ANALYSIS,
|
7951
7951
|
...STYLE_TABLE_PARAM.FLAMINGO,
|
7952
7952
|
},
|
7953
7953
|
[WATER_SYSTEMS_NAME.EFFICIENCY_AND_PERFORMANCE]: {
|
@@ -8066,12 +8066,12 @@ const ASSET_CATEGORY_PARAMS = {
|
|
8066
8066
|
DATA_ASSET_PARAMETER_FIELDS[ENUM_ASSET_PARAMETERS.VM_FAN_SPEED],
|
8067
8067
|
DATA_ASSET_PARAMETER_FIELDS[ENUM_ASSET_PARAMETERS.VM_RECIRCULATION_RATE],
|
8068
8068
|
],
|
8069
|
-
[WATER_SYSTEMS_NAME.
|
8070
|
-
DATA_ASSET_PARAMETER_FIELDS[ENUM_ASSET_PARAMETERS.
|
8071
|
-
DATA_ASSET_PARAMETER_FIELDS[ENUM_ASSET_PARAMETERS.
|
8072
|
-
DATA_ASSET_PARAMETER_FIELDS[ENUM_ASSET_PARAMETERS.
|
8073
|
-
DATA_ASSET_PARAMETER_FIELDS[ENUM_ASSET_PARAMETERS.
|
8074
|
-
DATA_ASSET_PARAMETER_FIELDS[ENUM_ASSET_PARAMETERS.
|
8069
|
+
[WATER_SYSTEMS_NAME.DATA_ANALYSIS]: [
|
8070
|
+
DATA_ASSET_PARAMETER_FIELDS[ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_RETURN_TEMPERATURE],
|
8071
|
+
DATA_ASSET_PARAMETER_FIELDS[ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_SUPPLY_TEMPERATURE],
|
8072
|
+
DATA_ASSET_PARAMETER_FIELDS[ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_WET_BULB_TEMPERATURE],
|
8073
|
+
DATA_ASSET_PARAMETER_FIELDS[ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_RANGE],
|
8074
|
+
DATA_ASSET_PARAMETER_FIELDS[ENUM_ASSET_PARAMETERS.DATA_ANALYSIS_APPROACH],
|
8075
8075
|
],
|
8076
8076
|
[WATER_SYSTEMS_NAME.EFFICIENCY_AND_PERFORMANCE]: [
|
8077
8077
|
DATA_ASSET_PARAMETER_FIELDS[ENUM_ASSET_PARAMETERS.EFFICIENCY_DAILY_AVERAGE],
|
@@ -9782,6 +9782,7 @@ const ATO_COMPONENTS_GROUP_DATA = {
|
|
9782
9782
|
value: '',
|
9783
9783
|
isEditable: true,
|
9784
9784
|
maxSizeValue: new go.Size(140, 14),
|
9785
|
+
waterSystem: WATER_SYSTEMS_NAME.VISUAL_MANAGEMENT,
|
9785
9786
|
})),
|
9786
9787
|
visible: true,
|
9787
9788
|
assetLayers: ATO_ASSET_LAYERS.PERFORMANCE,
|
@@ -9798,14 +9799,15 @@ const ATO_COMPONENTS_GROUP_DATA = {
|
|
9798
9799
|
group: 100,
|
9799
9800
|
padding: new go.Margin(0, 0, 0, 0),
|
9800
9801
|
loc: '30 350',
|
9801
|
-
...DATA_WATER_SYSTEMS[WATER_SYSTEMS_NAME.
|
9802
|
+
...DATA_WATER_SYSTEMS[WATER_SYSTEMS_NAME.DATA_ANALYSIS],
|
9802
9803
|
minSizeValue: new go.Size(100, NaN),
|
9803
9804
|
selectable: false,
|
9804
|
-
dataTable: ASSET_CATEGORY_PARAMS[WATER_SYSTEMS_NAME.
|
9805
|
+
dataTable: ASSET_CATEGORY_PARAMS[WATER_SYSTEMS_NAME.DATA_ANALYSIS].map((e) => ({
|
9805
9806
|
...e,
|
9806
9807
|
value: '',
|
9807
9808
|
isEditable: true,
|
9808
9809
|
maxSizeValue: new go.Size(120, 14),
|
9810
|
+
waterSystem: WATER_SYSTEMS_NAME.DATA_ANALYSIS,
|
9809
9811
|
})),
|
9810
9812
|
assetLayers: ATO_ASSET_LAYERS.PERFORMANCE,
|
9811
9813
|
extendedData: {
|
@@ -9829,6 +9831,7 @@ const ATO_COMPONENTS_GROUP_DATA = {
|
|
9829
9831
|
value: '',
|
9830
9832
|
isEditable: true,
|
9831
9833
|
maxSizeValue: new go.Size(120, 14),
|
9834
|
+
waterSystem: WATER_SYSTEMS_NAME.EFFICIENCY_AND_PERFORMANCE,
|
9832
9835
|
})),
|
9833
9836
|
assetLayers: ATO_ASSET_LAYERS.PERFORMANCE,
|
9834
9837
|
extendedData: {
|
@@ -9852,6 +9855,7 @@ const ATO_COMPONENTS_GROUP_DATA = {
|
|
9852
9855
|
value: '',
|
9853
9856
|
isEditable: true,
|
9854
9857
|
maxSizeValue: new go.Size(120, 14),
|
9858
|
+
waterSystem: WATER_SYSTEMS_NAME.WATER_AND_ENERGY_CONSUMPTION,
|
9855
9859
|
})),
|
9856
9860
|
assetLayers: ATO_ASSET_LAYERS.PERFORMANCE,
|
9857
9861
|
extendedData: {
|
@@ -9875,6 +9879,7 @@ const ATO_COMPONENTS_GROUP_DATA = {
|
|
9875
9879
|
value: '',
|
9876
9880
|
isEditable: true,
|
9877
9881
|
maxSizeValue: new go.Size(130, 14),
|
9882
|
+
waterSystem: WATER_SYSTEMS_NAME.CHEMICALS_CONSUMPTION,
|
9878
9883
|
})),
|
9879
9884
|
assetLayers: ATO_ASSET_LAYERS.PERFORMANCE,
|
9880
9885
|
extendedData: {
|
@@ -9898,6 +9903,7 @@ const ATO_COMPONENTS_GROUP_DATA = {
|
|
9898
9903
|
value: '',
|
9899
9904
|
isEditable: true,
|
9900
9905
|
maxSizeValue: new go.Size(130, 14),
|
9906
|
+
waterSystem: WATER_SYSTEMS_NAME.DESIGN_PARAMETERS,
|
9901
9907
|
extendedDataIsFromPlugin: {
|
9902
9908
|
maxSizeValue: new go.Size(230, 14),
|
9903
9909
|
},
|
@@ -9924,6 +9930,7 @@ const ATO_COMPONENTS_GROUP_DATA = {
|
|
9924
9930
|
value: '',
|
9925
9931
|
isEditable: true,
|
9926
9932
|
maxSizeValue: new go.Size(130, 14),
|
9933
|
+
waterSystem: WATER_SYSTEMS_NAME.SYSTEM_KPIS__COOLING_TOWER__PERFORMANCE,
|
9927
9934
|
})),
|
9928
9935
|
assetLayers: ATO_ASSET_LAYERS.PERFORMANCE,
|
9929
9936
|
extendedData: {
|